PN3245
PN3245
PN3245
l Quality by design and Class A manufacturing Perkins actively pursues product support
improvements enhance product reliability while excellence with our distribution network investing
maintaining Perkins reputation for durability. in their territory to provide you with a consistent
quality of support across the globe.
l Throughout the entire life of a Perkins engine, we
provide access to genuine factory specification
parts giving reassurance that you receive excellent
quality for the lowest possible cost, wherever
your Perkins powered machine is operating in the
world.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Photographs are for illustrative purposes only and may not reflect final specification.
Final weight and dimensions will depend on completed specification.
Information subject to selected configuration, and subject to change without notice.
Engine power measured per ISO 14396:2002
PN3245/02/21 Produced in England ©2021 Perkins Engines Company Limited
1103A-33 Electric Power Engines
Power range 1500 rpm 28-61 kW (engine gross power)
Power range 1800 rpm 33-71 kW (engine gross power)
Emissions Fuel optimised
Specification
Model
1103A-33G 1103A-33TG1 1103A-33TG2
Configuration ElectropaK
Cylinders 3 vertical in-line
Displacement, litres (in3) 3.3 (201)
Aspiration Naturally aspirated Turbocharged
Bore and stroke, mm (in) 105 x 127 (4.1 x 5.0)
Combustion system Direct injection
Compression ratio 19.25:1 17.25:1
Exhaust aftertreatment N/A
Rotation (viewed from flywheel) Anti-clockwise, viewed from flywheel
Total lubricating oil capacity, litres (US gal) 8.3 (2.2)
Cooling system Watercooled
Total coolant capacity, litres (US gal) 10.2 (2.7)
Technical information
Engine Power Typical Prime Fuel Consumption
Speed Type of Generator
Model Gross Net Output* (Net) 110% 100% 75% 50%
Operation
rpm kW (hp) kW (hp) kVA kWe g/kWh g/kWh g/kWh g/kWh
Prime 28.2 (38) 27.7 (37) 30 24
1500 212 211 216 231
Standby 31 (42) 30 (41) 33 26
1103A-33G
Prime 33 (45) 32 (43) 35 28
1800 221 223 226 240
Standby 37 (49) 35 (48) 38 31
Prime 42 (57) 41 (55) 45 36
1500 211 207 209 220
Standby 47 (62) 46 (61) 50 40
1103A-33TG1
Prime 51 (68) 49 (66) 53 43
1800 215 212 218 237
Standby 55 (73) 54 (72) 59 47
Prime 55 (74) 54 (72) 60 48
1500 217 218 215 224
Standby 61 (81) 59 (80) 66 53
1103A-33TG2
Prime 63 (85) 61 (82) 68 55
1800 216 213 218 230
Standby 71 (94) 68 (91) 75 60
*Generator powers are typical and based on typical alternator efficiencies and a
power factor (cos θ) or 0.8.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Photographs are for illustrative purposes only and may not reflect final specification.
Final weight and dimensions will depend on completed specification.
Information subject to selected configuration, and subject to change without notice.
Engine power measured per ISO 14396:2002
PN3245/02/21 Produced in England ©2021 Perkins Engines Company Limited
1103A-33 Electric Power Engines
Power range 1500 rpm 28-61 kW (engine gross power)
Power range 1800 rpm 33-71 kW (engine gross power)
Emissions Fuel optimised
Standard equipment
Model
1103A-33G 1103A-33TG1 1103A-33TG2
Electro unit or ElectropaK ElectropaK ElectropaK ElectropaK
Radiator fitted ü ü ü
Fuel filter, engine mounted ü ü ü
Water separator N/A N/A N/A
Fuel priming pump (manual/electric) Manual Manual Manual
Fuel cooler (not required for most
N/A N/A N/A
installations)
Air filter, engine mounted ü ü ü
Engine ECM, engine mounted N/A N/A N/A
Wiring harness to ECM N/A N/A N/A
Wiring harness (all connectors to
N/A N/A N/A
single customer interface)
Starter motor ü ü ü
Battery charging alternator ü ü ü
Flywheel housing ü ü ü
Flywheel ü ü ü
Fan ü ü ü
Fan guard ü ü ü
Temperature and oil pressure for
ü ü ü
automatic stop/alarm configurable
Model
1103A-33G 1103A-33TG1 1103A-33TG2
Configuration ElectropaK
Dimensions, H x L x W, mm (in) 951 x 1000 x 629 (34.7 x 39.3 x 24.7) 951 x 1049 x 634 (34.7 x 41.3 x 24.9)
Dry weight, kg (lb) 412 (908) 420 (926)
Prime power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12
hours of operation.
Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Photographs are for illustrative purposes only and may not reflect final specification.
Final weight and dimensions will depend on completed specification.
Information subject to selected configuration, and subject to change without notice.
Engine power measured per ISO 14396:2002
PN3245/02/21 Produced in England ©2021 Perkins Engines Company Limited