Dynamic Cone Penetrometer (DCP) Test Bs 1377:part 9:1990

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ENGINEER EMPLOYER CONTRACTOR

ENG. JUDE B MATSIKO TOTAL ENERGIES EPISLON UGANDA LIMITED

SUPPLY OF REPLACEMENT HOUSES FOR EACOP PROJECT, LOT 4


DYNAMIC CONE PENETROMETER (DCP) TEST BS 1377:Part 9:1990
Spot chainge Sembabule
DCP Zero Reading 74
Off-set NA
Date 28/03/2022
Surface condition Natural Ground
Penetration Rate of
No. of Penetration/ Cumulative CBR PAP Kirungi Emma
Corrected For Penetration AV. CBR
Blows Depth [mm] Blows Value Technician Stephen
Zero Reading [mm/Blow]
Trial Pit No.3
1 0 74 0 0
2 2 110 36 2 18.0 14
3 2 130 56 4 10.0 26 Number of Blows
4 2 160 86 6 15.0 17
5 2 184 110 8 12.0 22
6 1 215 141 9 31.0 8 0 20 40 60 80 100
12.9
7 1 245 171 10 30.0 8 0

8 1 282 208 11 37.0 7


9 1 315 241 12 33.0 7 200

10 1 345 271 13 30.0 8

Depth [mm]
11 1 370 296 14 25.0 10 400
12 1 416 342 15 46.0 5
13 2 442 368 17 13.0 20 600
14 2 457 383 19 7.5 36
15 2 490 416 21 16.5 16 800
16 2 530 456 23 20.0 13 18.3
17 2 557 483 25 13.5 19 1000
18 2 586 512 27 14.5 18
19 2 631 557 29 22.5 11 1200
20 2 651 577 31 10.0 26
21 2 688 614 33 18.5 14
22 3 710 636 36 7.3 37 CBR
23 3 742 668 39 10.7 25
24 3 776 702 42 11.3 23
25 3 793 719 45 5.7 48 0.0 20.0 40.0 60.0 80.0
26 4 810 736 49 4.3 65 0
27 3 833 759 52 7.7 35
200
Depth [mm]

28 3 855 781 55 7.3 37


29 3 873 799 58 6.0 45 400
30 2 892 818 60 9.5 28
29.5 600
31 2 908 834 62 8.0 34
32 2 928 854 64 10.0 26 800
33 4 954 880 68 6.5 42
34 4 977 903 72 5.8 48 1000
35 3 1012 938 75 11.7 23 1200
36 1 1037 963 76 25.0 10
37 1 1074 1000 77 37.0 7
38 1 1190 1116 78 116.0 2
39 1 1195 1121 79 5.0 55 Top 300mm 13%
40 1 1232 1158 80 37.0 7 Middle 600mm 18%
41 1 1260 1186 81 28.0 9 Bottom 1200mm 30%