Variable Frequency Vibrators Controlled Through Rotary Switches With Connection Extractable
Variable Frequency Vibrators Controlled Through Rotary Switches With Connection Extractable
Variable Frequency Vibrators Controlled Through Rotary Switches With Connection Extractable
AP09020G
LIST OF CONTENTS
SAFETY INSTRUCTION...............................................................................................................................................2
DECLARATION OF CONFORMITY ...........................................................................................................................3
FUNCTIONAL DESCRIPTION FEEDERS.................................................................................................................4
SETTING REFERENCE VALUE OF TENSION ON THE LOAD.............................................................................4
SETTING INVERTER-OK / INVERTER-RUN............................................................................................................4
SETTING PNP/NPN START AND SENSOR PNP/NPN .............................................................................................5
SETTING FREQUENCY ...............................................................................................................................................5
SETTING SOFT START AND SOFT STOP.................................................................................................................5
SETTING BRAKE FORCE ............................................................................................................................................6
SETTING START DELAY .............................................................................................................................................6
SETTING STOP DELAY................................................................................................................................................7
SETTING PROPORTIONAL AND INTEGRAL PARAMETERS ..............................................................................7
SETTING CURRENT LIMIT ........................................................................................................................................8
TECHNICAL SPECIFICATION ...................................................................................................................................9
WIRING TABLE ...........................................................................................................................................................10
START UP .....................................................................................................................................................................11
SOLUTIONS OF PROBLEMS ....................................................................................................................................12
OPENING INSTRUCTIONS .......................................................................................................................................12
OPERATION MODES OF THE DEVICE ..................................................................................................................13
PARTS IDENTIFICATION OF DEVICE AP09020G................................................................................................14
PARTS IDENTIFICATION OF DEVICE AP090206.................................................................................................15
NOTE:............................................................................................................................................................................16
SAFETY INSTRUCTION
Before the start-up of the power supply read carefully this instruction manual.
Attention: in order to reduce fire risks, electric shock or accident when carrying out
installation work and making connections please observe the following safety
instructions:
Install the equipment in a place clean, dry and not subject to vibrations
Do not use in presence of gas or flammable liquids
Installation must be made from qualified staff
Isolate from mains before installation or opening, as well as for fuse changes or
post installation modifications
Ensure that all connection are secure and protected
The earth connection must be checked after installation
Before putting into operation check if the local supply voltage conforms the rated
voltage
Verify absence of ground dispersions into the connections between power supply
and vibrator and use shielded cable for this connection
DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product FEEDERS
AP09020G is in conformity with the following standards or
standardization documents:
DIGISYSTEM srl
VIA FLEMING, 7 e 9
40024 CASTEL SAN PIETRO (BO)
TEL. +39-51-943812 FAX +39-51-948350
ISCR.TRIB.BO 61078
CCIAA 0346208
Cod.Fisc. 01561001205
Part.Iva 01561001205
Franco BARZANTI
Technical manager
SETTING FREQUENCY
The value of frequency are settable through rotating switches SW3, in order from left to right are
defined hundreds, tens, units, tenths of Hz.
0 5 0 0
To make this setting place the device with the rotating switch of houndreds at 5, then power-up
the device; the rotating switch of units sets the soft start and the rotating switch of tenths sets the
soft stop.
5 0 2 4
In the example the soft start (2) is set at 1 Sec. and soft stop (4) at 2 Sec.
Each value is 0,5 Sec. The value 0 for soft start is equal to 0,1 Sec. for soft stop enables the brake.
7 0 5 0
To set start delay put the device with the rotating switch of hundreds to 3, the rotating switch of tens, units,
tenths sets the start delay.
3 0 9 0
To set stop delay put the device with the rotating switch of hundreds to 4, the rotating switch of
tens, units, tenths sets the stop delay.
4 1 5 0
6 0 4 2
The example sets the proportional parameter at value 4 and integral parameter at value 2.
The parameters at default have the value 6 0 3 0. The range of sets is from 0 to 9.
2 1 0 0
The example sets the current limit at 1,00A. The range of sets is from 0,01 to 3,00/6,00 Ampere.
If you set a limit greater than the target equipment (3/6A), the inverter takes the maximum
permissible limit.
If in the same vibrator there are more coils connected in parallel, the limit current to set is the sum
of the currents of all coils.
TECHNICAL SPECIFICATION
Power supply: from 85 to 280Vac, frequency 50 or 60 Hz
Voltage output: soft-start with selectable ramp from 0,1 to 4,5 seconds in steps of 0,5
sec.
WIRING TABLE
SIGNAL WIRING
ACC-1 +5V SUPPLY ACCELEROMETER 3x0,5 BROWN +5Vdc SENSOR
ACC-2 INPUT ACCELEROMETER 3x0,5 GREEN Output Accelerometer
ACC-3 0V SUPPLY ACCELEROMETER 3x0,5 WHITE 0V
Note: The body of the vibrator must be grounded with a appropriate wire.
Before supplying the device verify that there are not ground dispersions on wires
connecting the power supply to the vibrator.
START UP
In practice, the search of the resonance frequency is made by checking the effects on the product
feeding obtained by regulating the rotating switches.
Than, proceed by further trials until you find the position of the rotating switches SW3 which
determines the best vibration.
After having reached it increase (or decrease) the potentiometer to obtain the required vibration
level
N.B.: The system maintain the same settings at next start, a stop command should be given
before power off. If you replace the equipeme, repeat start up.
Install in a clean, dry and make sure that is not subject to vibration
SOLUTIONS OF PROBLEMS
OPENING INSTRUCTIONS
To prevent accidents to the operator disconnect the power supply cable,
wait at least 5 minutes to discharge electrolytic capacitors.
Remove screws on bottom panel (X3).
RUN OFF ON
STOP OFF OFF
FAULT ON OFF
SATURATION ON ON
The following data should be reported when assistence is required: Model APxxxxxx,
production lot, power or current required from the load, power supply, remote signals.
Rev. 2.0 Page 14 of 16 20/20/2020
Digisystem srl User Manual AP09020G_ENG
The following data should be reported when assistence is required: Model APxxxxxx,
production lot, power or current required from the load, power supply, remote signals.
Rev. 2.0 Page 15 of 16 20/20/2020
Digisystem srl User Manual AP09020G_ENG
NOTE: