Variable Frequency Vibrators Controlled Through Rotary Switches With Connection Extractable

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Digisystem srl User Manual AP09020G_ENG

VARIABLE FREQUENCY VIBRATORS


CONTROLLED THROUGH ROTARY
SWITCHES WITH CONNECTION
EXTRACTABLE

AP09020G

ORDER CODES: CURRENT


AP09010G IP20 version for a Cabinet - AP090106 IP54 version for Stand Alone 3A
AP09020G IP20 version for a Cabinet - AP090206 IP54 version for Stand Alone 6A
AP09030G IP20 version for a Cabinet - AP090306 IP20 version for Stand Alone 10A
AP09020B IP54 version whith double Han and circle connector for option wiring 6A
AP090205 IP54 version for Stand Alone whith fairlead whithot cable 6A
AP090302 IP54 version for Stand Alone whith fairlead and cable. 10A version only IP20

Rev. 2.0 Page 1 of 16 20/05/2020


Digisystem srl User Manual AP09020G_ENG

LIST OF CONTENTS
SAFETY INSTRUCTION...............................................................................................................................................2
DECLARATION OF CONFORMITY ...........................................................................................................................3
FUNCTIONAL DESCRIPTION FEEDERS.................................................................................................................4
SETTING REFERENCE VALUE OF TENSION ON THE LOAD.............................................................................4
SETTING INVERTER-OK / INVERTER-RUN............................................................................................................4
SETTING PNP/NPN START AND SENSOR PNP/NPN .............................................................................................5
SETTING FREQUENCY ...............................................................................................................................................5
SETTING SOFT START AND SOFT STOP.................................................................................................................5
SETTING BRAKE FORCE ............................................................................................................................................6
SETTING START DELAY .............................................................................................................................................6
SETTING STOP DELAY................................................................................................................................................7
SETTING PROPORTIONAL AND INTEGRAL PARAMETERS ..............................................................................7
SETTING CURRENT LIMIT ........................................................................................................................................8
TECHNICAL SPECIFICATION ...................................................................................................................................9
WIRING TABLE ...........................................................................................................................................................10
START UP .....................................................................................................................................................................11
SOLUTIONS OF PROBLEMS ....................................................................................................................................12
OPENING INSTRUCTIONS .......................................................................................................................................12
OPERATION MODES OF THE DEVICE ..................................................................................................................13
PARTS IDENTIFICATION OF DEVICE AP09020G................................................................................................14
PARTS IDENTIFICATION OF DEVICE AP090206.................................................................................................15
NOTE:............................................................................................................................................................................16

SAFETY INSTRUCTION
Before the start-up of the power supply read carefully this instruction manual.
Attention: in order to reduce fire risks, electric shock or accident when carrying out
installation work and making connections please observe the following safety
instructions:
Install the equipment in a place clean, dry and not subject to vibrations
Do not use in presence of gas or flammable liquids
Installation must be made from qualified staff
Isolate from mains before installation or opening, as well as for fuse changes or
post installation modifications
Ensure that all connection are secure and protected
The earth connection must be checked after installation
Before putting into operation check if the local supply voltage conforms the rated
voltage
Verify absence of ground dispersions into the connections between power supply
and vibrator and use shielded cable for this connection

Attention: Hazardous Voltage

If these instructions are not followed serious injury to persons or


damages to things can be caused.
Rev. 2.0 Page 2 of 16 20/20/2020
Digisystem srl User Manual AP09020G_ENG

DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product FEEDERS
AP09020G is in conformity with the following standards or
standardization documents:

LVD CEI EN60439-1 (low voltage devices)

EMC CEI EN50082-2 (noises immunity in industrial plants)

EMC CEI EN50081-2 (noises emissions for industrial plants applications)

According to the provisions of the regulations 73/23/EEC, 93/68/EEC and 89/336/EEC if


operating and connection instructions, as mentioned into the instruction manual, are observed.

DIGISYSTEM srl
VIA FLEMING, 7 e 9
40024 CASTEL SAN PIETRO (BO)
TEL. +39-51-943812 FAX +39-51-948350
ISCR.TRIB.BO 61078
CCIAA 0346208
Cod.Fisc. 01561001205
Part.Iva 01561001205

Castel San Pietro Terme 22/05/2020

Franco BARZANTI
Technical manager

Rev. 2.0 Page 3 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

FUNCTIONAL DESCRIPTION FEEDERS


Using a variable frequency power source for vibratory feeders, the job of optimization of the
vibrating system can be simplified.
To obtain the condition of resonance of the mechanical vibrating system (coil, springs, container,
etc..), is sufficient to modify the frequency through the 4 rotating switch on the panel of the power
supply; in order from left to right are defined hundreds, tens, units, tenths of Hz.
Because this regulation can be done while the system is running the optimal frequency can be
determined very quickly.
This inverter for vibrators is housed in a box that has also function of heat sink.
It can be fixed to a panel with two M6 screws and electrical connections are made with
connectors.
The power supply is protected through internal fuses.
The overload is controlled from an electronic protection with autoreset and is signalled from a red
led; after five autoreset the inverter stay in fault state, while a green led signals the Run state.
The device is protect from short circuit of the load.
The inverter has a temperature sensor for overheating, if the internal temperature is over 70°, the
inverter goes to stop state and the red led blinks.
The switch SW4 enable (up) or disable (down) the accelerometer sensor.
The inverter is factory set with the switch SW1 down.
The switch SW1 invert the operation of sensor enable run (PC3) START connector pin 4:
Up, the device detects sensor enable run
Down, the device detects that sensor enable run
The device at power-on is in stop state, then to enable run the load set the external command or
use a floating contact in the (PC3) START connector pin 2.

SETTING REFERENCE VALUE OF TENSION ON THE LOAD


The value of external reference voltage is adjustable in the connector POT. (access PC4)
The jumper JS1 (closed) define the possibility of giving the reference voltage 0-10V external,
otherwise (open) for a 10K potentiometer or an external reference from 0-5V.

SETTING INVERTER-OK / INVERTER-RUN


Signaling function inverter ok/run through a contact in the connector INV.OK is settable whith
jumper JS2 inverter-ok (open), inverter-run (closed).
With Inverter-OK relay contact NO is closed if the inverter don t sees failures.
With Inverter-RUN relay contact NO is closed if the inverter is running.

Rev. 2.0 Page 4 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

SETTING PNP/NPN START AND SENSOR PNP/NPN


The run command and the sensor are settable by jumper through PNP/NPN input,
start (H2 2 positions), sensor (H3 2 positions). The jumper on the right set PNP command or PNP
sensor, jumper on the left set NPN command or NPN sensor.

SETTING FREQUENCY
The value of frequency are settable through rotating switches SW3, in order from left to right are
defined hundreds, tens, units, tenths of Hz.

0 5 0 0

In the example the frequency is set to 50,0 Hz.


The data of frequency can be set from 10,0 Hz to 140,0 Hz.

SETTING SOFT START AND SOFT STOP


Allows you to set the start ramp and the stop ramp when there is a start and stop command.
The devices, for default, have set the soft start and soft stop at 0,5 Sec.

To make this setting place the device with the rotating switch of houndreds at 5, then power-up
the device; the rotating switch of units sets the soft start and the rotating switch of tenths sets the
soft stop.

5 0 2 4

In the example the soft start (2) is set at 1 Sec. and soft stop (4) at 2 Sec.
Each value is 0,5 Sec. The value 0 for soft start is equal to 0,1 Sec. for soft stop enables the brake.

Rev. 2.0 Page 5 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

SETTING BRAKE FORCE


The function brake allows to have the stop of vibrator much faster.
Enable the brake: power-up the device with SW3 set at 5 0 x 0 , wait 3 sec., shut down.
To set the brake force power-up the device with the rotating switch of houndreds at 7, the rotating
switch of tens, units and tenths sets the brake force.

7 0 5 0

The example sets the brake force at 5,0 %.


The range of values is from 0,1 % to 99,9 %.

SETTING START DELAY


Allows to set the start delay.
The device at default have the start delay at 0 Sec.

To set start delay put the device with the rotating switch of hundreds to 3, the rotating switch of tens, units,
tenths sets the start delay.

3 0 9 0

The example sets the start delay at 9,0 Sec.


The range of values is from 0,0 to 30,0 Sec.

Rev. 2.0 Page 6 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

SETTING STOP DELAY


Allows to set the stop delay.
The device at default have the stop delay at 0 Sec.

To set stop delay put the device with the rotating switch of hundreds to 4, the rotating switch of
tens, units, tenths sets the stop delay.

4 1 5 0

The example sets the stop delay to 15,0 Sec.


The range of values is from 0,0 to 30,0 Sec.

SETTING PROPORTIONAL AND INTEGRAL PARAMETERS


This parameters optimize the compensation of load and power supply.
When you have large load or power supply variations, increasing the parameter proportional
increase the speed of compensation. Increasing the integral parameter dampens any oscillations of
to the system.
To make this setting power-up the device with the rotating switch of hundreds at 6, the rotating
switch of units sets the proportional parameter and the rotating switch of tenths sets the integral
parameter.

6 0 4 2

The example sets the proportional parameter at value 4 and integral parameter at value 2.
The parameters at default have the value 6 0 3 0. The range of sets is from 0 to 9.

Rev. 2.0 Page 7 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

SETTING CURRENT LIMIT


This function allow to set the maximum permissibile current to the magnet at a set value.
To make this setting power-up the device with the rotating switch of hundreds at 2, the rotating
switch of tens sets the ampere, the rotating switch of units sets the ampere tenths and the rotating
switch of tenths sets the ampere cents.

2 1 0 0

The example sets the current limit at 1,00A. The range of sets is from 0,01 to 3,00/6,00 Ampere.
If you set a limit greater than the target equipment (3/6A), the inverter takes the maximum
permissible limit.
If in the same vibrator there are more coils connected in parallel, the limit current to set is the sum
of the currents of all coils.

IF YOU WISH TO RETURN TO SET OR CHANGE SETTING THE FREQUENCY,


WAIT FOR 3 SEC, TURN OFF, SELECT THE NEW SET OR THE FREQUENCY AND
POWER ON AGAIN. PREVIOUS SETTINGS ARE SAVED IN MEMORY.

Rev. 2.0 Page 8 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

TECHNICAL SPECIFICATION
Power supply: from 85 to 280Vac, frequency 50 or 60 Hz

Output voltage: from 0 to 115Vca (with power supply 115Vca)


from 0 to 230Vca (with power supply 230Vca)

Output compensation: compensation of power supply variations and weight variations


(if the output voltage ranges from 20% to 95% of input voltage)

Output frequency: from 10,0 to 140,0 Hz in step of 0,1 Hz

Current: maximum current 8 Ampere peak (about 3 Arms)


maximum current 16 Ampere peak (about 6 Arms)
maximum current 30 Ampere peak (about 10 Arms)
limited from a electronic circuit with autoreset

Fuses: 4 A fast action 250Vac; dimensions 5x20 VERSION 3A


6,3 A fast action 250Vac; dimensions 5x20 VERSION 6A, 10A

Voltage output: soft-start with selectable ramp from 0,1 to 4,5 seconds in steps of 0,5
sec.

Remote commands: start/stop with external voltage PNP or floating contact


(12 ÷ 24 Vdc, current 20 mA) optocoupled

Mechanical protection: IP 54 (IP20 open version)

EMI Protection: meets following regulations: LVD CEI EN60439-1


EMC CEI EN50082-2
EMC CEI EN50081-2
If observed wiring instructions.

Internal Connections: Connector 3 poles p 5 mains input M2


Connector 4 poles p 5 for output vibrator M3

Connector 4 poles p3,81 for start/stop command START


Connector 3 poles p3,81 for inverter ok/run INV.OK
Connector 3 poles p3,81 external reference 0÷5 / 0÷10Vdc POT
Connector 3 poles p3,81 for accelerometer ACC

Working temperature: ambient temperature max 45°

Dimensions/ Weight: - 150 x 123 x 100 mm (height, breadth, depth) / 1,2 Kg


fastening wheelbase 135 mm with M6 screws VERSION 3A
- 200 x 123 x 100 mm (height, breadth, depth) / 1,5 Kg
fastening wheelbase 175 mm with M6 screws VERSION 6A, 10A
(50/100mm must be provided in low side for connector insertion)

Rev. 2.0 Page 9 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

WIRING TABLE

PIN REF. SIGNAL DESCRIPTION WIRE mmq WIRE CONNECT TO:


SECTION COLOR
M2-1 3x1,5
GROUND CONNECTION YELLOW-GREEN EARTH
no shielded
M2-2 3x1,5
MAINS INPUT (NEUTRAL) BLUE Neutral 230 Vac
no shielded
M2-3 3x1,5
MAINS INPUT (PHASE) BROWN Phase 230 Vac
no shielded
(HAN-3)
SHIELD SHEATHING N.C.
M3-1
(HAN-T) 3x1,5
GROUND CONNECTION YELLOW-GREEN VIBRATOR BODY
M3-2 shielded
(HAN-1) 3x1,5
OUTPUT SUPPLY FOR VIBRATOR BLUE VIBRATOR
M3-3 shielded
(HAN-2) 3x1,5
OUTPUT SUPPLY FOR VIBRATOR BROWN VIBRATOR
M3-4 shielded

SIGNAL WIRING
ACC-1 +5V SUPPLY ACCELEROMETER 3x0,5 BROWN +5Vdc SENSOR
ACC-2 INPUT ACCELEROMETER 3x0,5 GREEN Output Accelerometer
ACC-3 0V SUPPLY ACCELEROMETER 3x0,5 WHITE 0V

POT-1 +5V SUPPLY POTENTIOMETER CW pot. 10K

INPUT REFERENCE VOLTAGE 0-10V 2x0,5 Input reference voltage


POT-2
o CURSOR POTENTIOMETER shielded or CURSOR
0V REFERENCE VOLTAGE 2x0,5
POT-3 0V or CCW
0V SUPPLY POTENTIOMETER shielded
INV OK-1 CONTATTO NC 3x0,5 Contact Closed
INV OK-2 C (COMMON) 3x0,5 12 Vdc, 24 Vdc
INV OK-3 CONTATTO NO 3x0,5 Contact Open
OUTPUT +24V SUPPLY SENSOR 3x0,5 24Vdc sensor or
START-1 BROWN
START/STOP COMMAND, SWITCH shielded SWITCH
INPUT +24V (10 mA)START/STOP 3x0,5 SWITCH or PNP/NPN
START-2 GREEN
COMMAND or SWITCH shielded command
0V REF. START/STOP COMMAND 0V 3x0,5 0V sensor or 0V Ref.
START-3 WHITE
SUPPLY SENSOR START/STOP shielded Input PNP/NPN
SENSOR FOR ENABLE SENSOR PNP/NPN
START-4
START/STOP COMMAND (see overflow)

Rev. 2.0 Page 10 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

Run through switch: connect switch between START-1 and START-2.


Run through external voltage: connect 0V in the START-3 and +12-24V in the START-2.
Run through sensor: connect 0V in the START-3, +12V-24V in the START-1 and
output sensor in the START-2.

Note: The body of the vibrator must be grounded with a appropriate wire.
Before supplying the device verify that there are not ground dispersions on wires
connecting the power supply to the vibrator.

START UP

Verify that the equipment is mounted in vertical position.


Verify the inverter is power-off.
Verify switch SW1 lever status is down so that the equipment can receive the start command
whitout other enable signal.
Verify switch SW4 lever status is down so that the equipment can operate.
whitout the acceleration sensor.
Verify that the equipment is locked and that all screws are tightened.
Verify that all connections and screws are fastened.
Set the frequency of load at factory value.
Connect the power supply to the mains 230 Vac through M2 (PC1) and to the vibrator through
M3 (PC2).
Turn on the inverter and set the start command through START (PC3)
The load is now supplied at the frequency and voltage of the power supply in POT\REF.

In practice, the search of the resonance frequency is made by checking the effects on the product
feeding obtained by regulating the rotating switches.
Than, proceed by further trials until you find the position of the rotating switches SW3 which
determines the best vibration.
After having reached it increase (or decrease) the potentiometer to obtain the required vibration
level

N.B.: The system maintain the same settings at next start, a stop command should be given
before power off. If you replace the equipeme, repeat start up.
Install in a clean, dry and make sure that is not subject to vibration

Rev. 2.0 Page 11 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

SOLUTIONS OF PROBLEMS

fault functional What to do


anomaly
Closing the power switch does not Device not Verify mains supply and input fuses;
turn on momentarily RED led DL1 supplied to locate fuses F1; see instructions to
open the device
Closing the power switch, led DL2 Switch SW1 Place switch SW1 down and send a
is off and RED led DL1 switches placed up start command from input cable
momentary on, but vibration doesn't
start
Closing the power switch, led DL2 Vibrator not Check wiring from power supply to
is on and RED led DL1 switches supplied vibrator; if the problem is not there
momentary on, but vibration doesn't may be there is a failure on drivers
start into the power supply
Closing the power switch and led Overload Turn anticlockwise the potentiometer.
DL1 switches regularly on and off condition Verify the load and the wiring; if the
problem persists contact factory
The load overheats Working Verify the output voltage and
frequency too low frequency
The vibrator is very noisy or magnet Air gap too large, Change frequency to move away from
and mobile part beat frequency or load resonance, decrease P-MAX
power supply threshold on load, increase air gap
incorrect
Maximum speed not reachable Maximum output Verify P-MAX trimmer and current
voltage low limit is set at maximun, check load
The device is in sleep mode, the red Accelerometer Give the command to stop, disable the
led does a double blink fault accelerometer, test without
If actions remarked on the table doesn't resolve the problem you may contact factory Digisystem
(e-mail [email protected] ).

OPENING INSTRUCTIONS
To prevent accidents to the operator disconnect the power supply cable,
wait at least 5 minutes to discharge electrolytic capacitors.
Remove screws on bottom panel (X3).

Rev. 2.0 Page 12 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

OPERATION MODES OF THE DEVICE


LED INDICATIONS

STATUS RED LED GREEN LED

RUN OFF ON
STOP OFF OFF

FAULT ON OFF

SATURATION ON ON

OVERHEATING BLINKER OFF


FAULT
2 FLASH OFF
ACCELEROMETER

CONTINUOUS CYCLE OPERATION


A continuous operation can involve, if working current reaches the maximum current (of the
vibrator coil), phenomena of thermal drift in the inductance of the vibrator.
Working near current limit of the power supply short interruptions of operation can be observed
due to the protection circuit for overcurrent.
The device can operate at continuous cycle until 3/6 Ampere depending on the version.

ALTERNATED CYCLE OPERATION


If the run command of the device is managed from a product presence or absence sensor, the start
and stop delay can be modified; in this operating mode there is a minimal thermal drift and
mechanical-electrical stress are reduced.

OPERATION WITH ACCELEROMETER


Using the device with an accelerometer there is a movement feedback.
The equipment recognizes the presence of the accelerometer Digisystem SP040600 when it is
connected and the switch SW4 is up, the output voltage of the device is modified automatically in
order to maintain the amplitude of set up vibrations.
The accelerometer is very sensitive therefore is important to install the sensor so that there are not
spurious vibrations but there are only the normal system vibrations. The positioning must be made
remembering that larger it is signal of the sensor , better is the precision in the maintenance of the
oscillation; this will be obtained installing the accelerometer with the arrow in the direction of the
oscillation and where oscillations have maximum amplitude (not more than 5 mm) peak to peak.
The device signals a fault of the accelerometer with 2 Flash of the red led and the load stop.
In this case turn-off the device disable accelerometer (SW4 lever = low) and turn-on the device.
For further information on the accelerometer see the manual SP040600.

Rev. 2.0 Page 13 of 16 20/20/2020


Digisystem srl User Manual AP09020G_ENG

PARTS IDENTIFICATION OF DEVICE AP09020G


PART REF. FUNCTION
Connector 3 poles p5 M2 Mains input 85-280Vac
Connector 4 poles p5 M3 Load output
Connector 4 poles p3,81 START Input for Start/stop command and sensor
Connector 3 poles p3,81 ACC Input for Accelerometer
Connector 3 poles p3,81 POT Input external reference or potentiometer
Connector 3 poles p3,81 INV-OK Output inverter OK / inverter START
Jumper JS1 Set reference voltage 0-10 Vdc closed o 0-5 Vdc open for POT. 10K
Jumper JS2 Set output INV-OK open o INV-RUN closed
Jumper H2, H3 Set start/stop and sensor PNP/NPN
Fuses F1 Mains fuses
Trimmer P1 Sets minimum reference voltage from analog reference
Trimmer P2 Sets maximum reference voltage from analog reference
Switch SW1 Invert sensor
Switch SW3 Set output frequency or another setting
Switch SW4 Enable accelerometer
Red led DL1 Power supply inhibited
Green led DL2 Power output available
Box X1 Anodized aluminum front panel
Front panel X2 Fastening front panel to the box
Screws X3 Fastening front panel to the box
Lower bracket X4 Lower bracket anodized aluminum
Hole X5 Fixing box to wall
Upper bracket X6 Upper bracket anodized aluminum

The following data should be reported when assistence is required: Model APxxxxxx,
production lot, power or current required from the load, power supply, remote signals.
Rev. 2.0 Page 14 of 16 20/20/2020
Digisystem srl User Manual AP09020G_ENG

PARTS IDENTIFICATION OF DEVICE AP090206


PART REF. FUNCTION
Fairlead PG11 PC1 Mains input 85-280Vac ACCESS TO M2
Fairlead PG13 or HAN conn. PC2 Load output ACCESS TO M3
Fairlead PG7 PC3 Input for Start/stop command and sensor ACCESS TO START
Fairlead PG7 PC4 Input for Accelerometer ACCESS TO ACC
Breaker I1 Mains switch
Green lamp L1 Power supply available
Fuses F1 Mains fuses
Jumper JS1 Set reference voltage 0-10 Vdc closed o 0-5 Vdc open for POT. 10K
Jumper JS2 Set output INV-OK open o INV-RUN closed
Jumper H2, H3 Set start/stop and sensor PNP/NPN
Trimmer P1 Set minimum reference voltage from analog reference
Trimmer P2 Set maximum reference voltage from analog reference
Potentiometer 10K P3 Sets reference voltage
Switch SW1 Set inversion control sensor of Start/stop
Switch SW3 Set output frequency or another setting
Switch SW4 Enable accelerometer
Red led DL1 Power supply inhibited
Green led DL2 Power output available
Box X1 Polycarbonate closing
Front panel X2 Fastening front panel to the box
Screws X3 Fastening front panel to the box
Lower bracket X4 Lower bracket anodized aluminum
Hole X5 Fixing box to wall
Upper bracket X6 Upper bracket anodized aluminum

The following data should be reported when assistence is required: Model APxxxxxx,
production lot, power or current required from the load, power supply, remote signals.
Rev. 2.0 Page 15 of 16 20/20/2020
Digisystem srl User Manual AP09020G_ENG

NOTE:

Rev. 2.0 Page 16 of 16 20/20/2020