Bayhydrol A 2695 - en - 80628498 07461945 jj07461963
Bayhydrol A 2695 - en - 80628498 07461945 jj07461963
Bayhydrol A 2695 - en - 80628498 07461945 jj07461963
Bayhydrol A 2695
Specification
Property Value Unit of measurement Method
Viscosity 1,000 - 3,500 mPa·s DIN EN ISO 3219/A.3
-1
at 23 °C, D = approx. 40 s
Non-volatile content 40 - 43 % DIN EN ISO 3251
(1g / 1h / 125°C)
pH 7.2 - 8.2 DIN ISO 976
(1:4 in demineralised water)
Other data*
Property Value Unit of measurement Method
Equivalent weight approx. 830 g/mol
Flash point > 95 °C DIN EN ISO 2719
(No flash point up to initial boiling
point)
Density at 20 °C approx. 1.06 g/ml DIN DIN EN ISO 2811
Acid value approx. 9.4 mg KOH/g DIN EN ISO 3682
OH % on solid approx. 5.0 %
*These values provide general information and are not part of the product specification.
page 1 of 3
Edition 2020-02-05
Solubility / thinnability ®
Bayhydrol A 2695 can be thinned with water in any ratio.
Compatibility Suitable co-reactants for the formulation of aqueous two-pack polyurethane
®
systems e.g. Bayhydur ultra 2487/1, XP 2451/1, XP 2655, ultra 304,
® ®
Desmodur N 3600 or Desmodur N 3900.
Properties / Applications Mainly for air- and forced-drying coating systems with a very high chemical
resistance.
The cured paint films are hard, tough but flexible, glossy and high-bodied
with good weather stability, lightfastness and superior chemical resistance.
®
Application of a clearcoat based on Bayhydrol A 2695 directly on wood may
lead to discoloration.
Storage - Storage in original sealed Covestro container.
page 2 of 3
Edition 2020-02-05
Storage time Covestro represents that, for a period of six months following the day
of shipment as stated in the respective transport documents, the product
will meet the specifications or values set forth in section "specifications or
characteristic data" above, what ever is applicable, provided that the product is
stored in full compliance with the storage conditions set forth in and referenced
under section "storage" above and is otherwise handled appropriately.
The lapse of the six months period does not necessarily mean that the
product no longer meets specifications or the set values. However, prior to
using said product, Covestro recommends to test such a product if it still
meets the specifications or the set values. Covestro does not make any
representation regarding the product after the lapse of the six months period
and Covestro shall not be responsible or liable in any way for the product
failing to meet specifications or the set values after the lapse of the six months
period.
Labeling and statutory requirements This product data sheet is only valid in conjunction with the latest edition of the
corresponding Safety Data Sheet. Any updating of safety-relevant information
– in accordance with statutory requirements – will only be reflected in the Safety
Data Sheet, copies of which will be revised and distributed. Information relating
to the current classification and labeling, applications and processing methods
and further data relevant to safety can be found in the currently valid Safety
Data Sheet.
The manner in which you use and the purpose to which you put and utilize our products, technical assistance and information (whether verbal,
written or by way of production evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is
imperative that you test our products, technical assistance, information and recommendations to determine to your own satisfaction whether our
products, technical assistance and information are suitable for your intended uses and applications. This application-specific analysis must at least
include testing to determine suitability from a technical as well as health, safety, and environmental standpoint. Such testing has not necessarily been
done by Covestro. Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which
are available upon request. All information and technical assistance is given without warranty or guarantee and is subject to change without notice.
It is expressly understood and agreed that you assume and hereby expressly release us from all liability, in tort, contract or otherwise, incurred in
connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized
and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with any claim of any patent relative to
any material or its use. No license is implied or in fact granted under the claims of any patent.
This product is not designated for the manufacture of a medical device or of intermediate products for medical devices1). [This product is also not
designated for other specifically regulated applications (e.g. including cosmetics, plant protection, fertilisers, plant strengtheners, food processing, food
contact and others). If the intended use of the product is for the manufacture of a medical device or of intermediate products for medical devices or
for other specifically regulated applications Covestro must be contacted in advance to provide its agreement to sell such product for such purpose.]
Nonetheless, any determination as to whether a product is appropriate for use in a medical device or intermediate products for medical devices, for Food
Contact products or cosmetic applications must be made solely by the purchaser of the product without relying upon any representations by Covestro.
1) Please see the "Guidance on Use of Covestro Products in a Medical Application" document.
Edition: January, 2018
Editor: Coatings, Adhesives & Specialties
Covestro Deutschland AG
Kaiser-Wilhelm-Allee 60 Contact:
51373 Leverkusen, Germany CAS Single Point of Contact EMEA
www.covestro.com e-mail: [email protected]
page 3 of 3
Edition 2020-02-05