Medidor de Potencia OTS-600 de LANDSCAPE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

OTS-600 Series Optical Sources, Meters,

Testers and Kits with Data Storage Capabilities

|
A LANscape ®

TRAINING
Solutions Product

features and benefits | The Corning Cable Systems OTS-600 Series is ideal

|
for optical network certification. The unit is designed for

SPLICE EQUIPMENT
Large LCD screen Ease of use
testing and troubleshooting of various telecommunica-
and soft key menus
tion networks, with ease of use achieved using a large
Source and meter Improves bi-directional color LCD screen, soft-key menus and a testing wizard.
in one unit testing While maintaining all the functionality expected from an
optical tester, data entry and navigation have been sim-
Auto wavelength Cuts typical testing

|
switching and detection time in half plified with a keypad similar to a cell phone. The OT-600

TEST EQUIPMENT
Series models provide source and meter in one unit to
USB data ports Convenient transfer improve bi-directional testing productivity, and the auto
of data
wavelength switching and detection feature cuts typical
testing time in half while reducing the potential for
errors. The power meter has a range of +10 to -70 dBm

|
SPLICE CLOSURES
with 40 calibrated wavelengths. An intuitive step-by-step
loss testing wizard walks the user through calculating
pass/fail criteria, referencing and setting the file name.

The USB data ports provide convenient transfer of


data to OTS-View Windows®-based PC Software for

|
HARDWARE
storage, viewing and printing of test results. The
OTS-600 Series units have data storage for up to
10,000 measurement results, USB data transfer
interface and a video inspection probe port. Both the

|
CABLE ASSEMBLIES
OT-600 and OS-400 Series units come standard with
a 650 nm visual fault locator (VFL) for convenient
troubleshooting of optical networks. The OTS-600
Series units are sold individually, and as test kits.
These kits include two units, an SC source adapter,
OTS-600 Series Light Source and
and SC, LC, and ST® Compatible Connector meter port

|
Power Meter | Photo LAN1193

CONNECTORS
adapters. The kits are packaged in a hard case for
convenient storage and protection during transit.

|
CABLES
|
PRETERMINATED SYSTEMS

Modular Screen and Keypad | Photo LAN1190

SPECIFICATION SHEET LAN-942-EN | PAGE 1


|
OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities
A LANscape ®
Solutions Product

Certification Wizard
The Corning Cable Systems OTS-600 Series features an intuitive
Certification Wizard which takes the user through testing step-by-step.

Step 1: User selects test standard which will be used to calculate


pass/fail thresholds. User can also create and save their own custom
criteria where they define the connector pair loss in dB, splice loss in
Screen Shot of Step 1 dB and cable loss coefficient in dB/km.

Step 2: According to the reference method selected, the user receives


an on-screen diagram to perform reference step.

Step 3: User inputs cable ID/file name.

Step 4: User inputs number of connector pairs, splices,


and system length.

Screen Shot of Step 2 Step 5: User can input job information.

Step 6: During the testing, the results are shown in tabular format mak-
ing it easy for the user to view results. The table conveniently shows any
saved data for that fiber, making reviewing and updating results simple
and efficient.

Screen Shot of Step 3

Screen Shot of Step 4 Screen Shot of Step 5 Screen Shot of Step 6

SPECIFICATION SHEET LAN-942-EN | PAGE 2


OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities

|
A LANscape ®

TRAINING
Solutions Product

Reporting the Results

|
The OTS-600 Series comes with OTS-View reporting

SPLICE EQUIPMENT
software for creating comprehensive certification
reports. The software allows the user to save, upload,
manage and print reports.

OTS-View allows users to customize the report by

|
uploading company logos, printing only pertinent

TEST EQUIPMENT
data fields and changing the pass/fail threshold.
The software automatically transfers the unit model,
serial number, tested date and other data from user
input fields (such as Location, Customer, Cable
Sample of Report
Type, etc.)

|
SPLICE CLOSURES
The output of the report can be printed or stored
electronically in HTML format for viewing with any
web browser, CSV format for viewing with MS Excel,
or TXT for viewing with a document editor.

|
HARDWARE
Connector Inspection
The OTS-600 Series comes ready for connector
inspection with a built-in video probe port and software.

|
The video inspection probe (VIP) allows for the inspec-

CABLE ASSEMBLIES
tion of a fiber optic connector’s end-face quality. The
resulting images can be used as documentation of
Video Inspection Probe (VIP) | Photo LAN1672 end-face quality and cleanliness.

With the purchase of the optional probe (VIPROBE-

|
DUAL), images can be stored on the OTS-600 unit in

CONNECTORS
JPG format.

A variety of precision inspection tips are available for


the inspection probe. The “universal” tips are used when
|
CABLES

viewing a patch cord connector end-face or when view-


ing a connector before plugging it into the patch panel.
The “bulkhead” tips are used when viewing a connector
|

on the backside of patch panels through the front of the


PRETERMINATED SYSTEMS

adapter. This allows for convenient inspection without


removing the connector from the patch panel.
OTS-600 Optical Tester | Photo LAN1668

SPECIFICATION SHEET LAN-942-EN | PAGE 3


|
OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities
A LANscape ®
Solutions Product

specifications |
Power Meter1
Model Numbers OM-610, OT-611MD, OT-612SD, OT-613QD

Power Meter Port Ge

Power Range2 10 to -70 dBm

Calibrated 800, 820, 830, 840, 850, 860, 870, 880, 910, 980, 1270, 1280, 1290, 1300, 1310,
Wavelengths (nm) 1320,1330, 1340, 1350, 1370, 1390, 1410, 1430, 1450, 1460, 1470, 1480, 1490,
1500, 1510,1520, 1530, 1540, 1550, 1560, 1570, 1580, 1590, 1600, 1610, 1620,
1630, 1640, 1650

Power Uncertainty3 ± 5% ± 1 nW

Resolution4 ± 0.01 dB

Automatic Offset Nulling Yes

Warmup Time5 None

Display Units dB/dBm/W

Automatic Wavelength Yes


Recognition6

Tone Detection 270 Hz, 1 kHz, 2 kHz

Battery Li-lon Battery with 7.5 hours typical life

Data Storage 128 Mb (>10,000 fiber results)

Warranty and 3 years


Calibration Interval

Size (H x W x D) 28.4 x 12.5 x 7.8 cm (11.19 x 4.83 x 3.06 in)

Weight 0.98 kg (2.16 lb)

Operating Temperature 0º to +50ºC (+32º to +122ºF)

Storage Temperature -20º to +70ºC (-4º to +158ºF)

Relative Humidity 5% to 95% non-condensing


1
Guaranteed unless otherwise specified. All specifications valid at 1550 nm and 23ºC ± 1ºC, with an FC connector.
2
In CW mode; sensitivity defined as 6 x RMS noise level.
3
For calibrated wavelengths.
4
From 10 dBm to -60 dBm.
5
For ± 0.05 dB and temperatures of > 18ºC.
6
At 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm and 1625 nm for power of > -50 dBm.

SPECIFICATION SHEET LAN-942-EN | PAGE 4


OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities

|
A LANscape ®

TRAINING
Solutions Product

specifications | (continued)

|
Optical Source1

SPLICE EQUIPMENT
Model Numbers OS-403RD OS-404RXD
OS-4RMDSD OS-4RMDSD

Central Wavelengths 850 ± 25 nm 1310 ± 20 nm


1300 -10/+50 nm 1550 ± 20 nm

|
TEST EQUIPMENT
Spectral Width2 50 nm (850 nm) ≤ 5 nm (1310 nm)
135 nm (1300 nm) ≤ 5 nm (1550 nm)

Output Power3 ≥ -20 dBm (850 nm) ≥ 1 dBm (1310 nm)


≥ -20 dBm (1300 nm) ≥ 1 dBm (1550 nm)

|
SPLICE CLOSURES
Auto Wavelength Switching Yes Yes

Tone Generation 270 Hz, 1 kHz, 2 kHz 270 Hz, 1 kHz, 2 kHz

Battery Life 50 hours 50 hours

Safety Class 1M Laser Product Class 1M Laser Product

|
HARDWARE
Visual Fault Locator (VFL)3

Emitter Type Laser Laser

|
CABLE ASSEMBLIES
Wavelength 650 nm 650 nm

Output Power 3 dBm 3 dBm

Safety Class 3R Laser Product Class 3R Laser Product

General

|
CONNECTORS
Size (H x W x D) 19.0 x 10.0 x 6.2 cm (7.5 x 4.0 x 2.5 in) 19.0 x 10.0 x 6.2 cm (7.5 x 4.0 x 2.5 in)

Weight 0.48 kg (1.1 lb) 0.48 kg (1.1 lb)

Warranty and 3 years 3 years


|

Calibration Interval
CABLES

Operating Temperature 0º to +50ºC (+32º to +122ºF) 0º to +50ºC (+32º to +122ºF)


|

Storage Temperature -20º to +70ºC (-4º to +158ºF) -20º to +70ºC (-4º to +158ºF)
PRETERMINATED SYSTEMS

Relative Humidity 5% to 95% non-condensing 5% to 95% non-condensing


1
Guaranteed unless otherwise specified. All specifications valid at 23º ± 1ºC, with an FC connector.
2
Values are RMS for FP lasers and -3 dB width for LEDs.
3
Typical values when coupled to detector with air gap.

SPECIFICATION SHEET LAN-942-EN | PAGE 5


|
OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities
A LANscape ®
Solutions Product

specifications | (continued)
Optical Tester1
Model Numbers OT-611MD OT-612SD
OT-613QD

Central Wavelengths 850 ± 25 nm 1310 ± 20 nm


1300 -10/+50 nm 1550 ± 20 nm

Spectral Width2 50 nm (850 nm) ≤ 5 nm (1310 nm)


135 nm (1300 nm) ≤ 5 nm (1550 nm)

Output Power ≥ -20 dBm (850 nm) ≥ 1 dBm (1310 nm)


≥ -20 dBm (1300 nm) ≥ 1 dBm (1550 nm)

Auto Wavelength Switching Yes Yes

Tone Generation 270 Hz, 1 kHz, 2 kHz 270 Hz, 1 kHz, 2 kHz

Safety Class 1M Laser Product Class 1M Laser Product


Guaranteed unless otherwise specified. All specifications valid at 23º ± 1ºC, with an FC connector.
1

Values are RMS for FP lasers and -3 dB width for LEDs.


2

SPECIFICATION SHEET LAN-942-EN | PAGE 6


OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities

|
A LANscape ®

TRAINING
Solutions Product

specifications | (continued)

|
SPLICE EQUIPMENT
Detector

Model Numbers OT-611MD OT-612SD


OT-613QD

Power Range1 10 to -70 dBm 10 to -70 dBm

|
Calibrated 800, 820, 830, 840, 850, 860, 870, 880, 910, 980, 1270, 1280, 1290, 1300, 1310,

TEST EQUIPMENT
Wavelengths (nm) 1320,1330, 1340, 1350, 1370, 1390, 1410, 1430, 1450, 1460, 1470, 1480, 1490,
1500, 1510, 1520, 1530, 1540, 1550, 1560, 1570, 1580, 1590, 1600, 1610, 1620,
1630, 1640, 1650

Power Uncertainty2 ± 5% ± 1 nW

|
Resolution3 ± 0.01 dB

SPLICE CLOSURES
Automatic Offset Nulling Yes

Display Units dB/dBm/W

Automatic Wavelength Yes

|
Recognition4

HARDWARE
Tone Detection 270 Hz, 1 kHz, 2 kHz

Battery Li-Ion Battery with 7.5 hours typical life

|
CABLE ASSEMBLIES
Data Storage 128 Mb (> 10,000 fiber results)

Warranty and 3 years


Calibration Interval

Size (H x W x D) 28.4 x 12.5 x 7.8 cm (11.19 x 4.83 x 3.06 in)

|
CONNECTORS
Weight 0.98 kg (2.16 lb)

Operating Temperature 0º to +50ºC (+32º to +122ºF)

Storage Temperature -20º to +70ºC (-4º to +158ºF)


|
CABLES

Relative Humidity 5% to 95% non-condensing

In CW mode; sensitivity defined as 6 x RMS noise level.


|

For calibrated wavelengths.


PRETERMINATED SYSTEMS

3
From 10 dBm to -60 dBm.
4
At 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm and 1625 nm for power of > -50 dBm.

SPECIFICATION SHEET LAN-942-EN | PAGE 7


|
OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities
A LANscape ®
Solutions Product

specifications | (continued)
Visual Fault Locator (VFL)

Central Wavelength Laser, 650 nm ± 10 nm

Pulse Continuous wave (CW)

Typical Output Power 1 3 dBm (2 mW)

Safety Class 3R Laser Product

General

Size (H x W x D) 28.4 x 12.5 x 7.8 cm (11.19 x 4.83 x 3.06 in)

Weight 0.98 kg (2.16 lb)

Operating Temperature 0º to +50ºC (+32º to +122ºF)

Storage Temperature -20º to +70ºC (-4º to +158ºF)

Relative Humidity 5% to 95% non-condensing

Typical values when coupled to detector with air gap.


1

SPECIFICATION SHEET LAN-942-EN | PAGE 8


OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities

|
A LANscape ®

TRAINING
Solutions Product

ordering information |

|
SPLICE EQUIPMENT
Part Number Description

Optical Source

OS-403RD Multimode Optical Source (850/1300 nm LED) with integrated 650 nm VFL; Li-Ion rechargeable
battery and AC power adapter; (1) SC source port adapter, (1) wrist strap and user’s manual

|
OS-404RXD Single-mode Optical Source (1310/1550 nm laser) with integrated 650 nm VFL; Li-Ion

TEST EQUIPMENT
rechargeable battery and AC power adapter; (1) SC source port adapter, (1) wrist strap and
user’s manual

OS-4RMDSD Single-mode/Multimode Optical Source (850/1300 nm LED and 1310/1550 nm laser)


with integrated 650 nm VFL; Li-Ion rechargeable battery and AC power adapter;
(2) SC source port adapters, (1) wrist strap and user’s manual

|
Optical Meter

SPLICE CLOSURES
OM-610 Optical Power Meter with 40 calibrated wavelengths; data storage for 10,000 traces; USB
cable for data transfer; OTS-View software; Li-Ion rechargeable battery and AC power adapter;
(1) SC meter port adapter, (1) wrist strap and user’s manual

Optical Tester

|
OT-611MD Multimode 2-Fiber Tester with 850/1300 nm LED source, optical power meter, and integrated

HARDWARE
650 nm VFL; (1) SC source port adapter, (1) SC meter port adapter, USB cable for data
transfer; OTS-View software; Li-Ion rechargeable battery and AC power adapter; (1) wrist
strap and user’s manual

OT-612SD Single-mode 2-Fiber Tester with 1310/1550 nm laser source, optical power meter, and

|
integrated 650 nm VFL; (1) SC source port adapter, (1) SC meter port adapter, USB cable

CABLE ASSEMBLIES
for data transfer; OTS-View software; Li-Ion rechargeable battery and AC power adapter;
(1) wrist strap and user’s manual

OT-613QD Single-mode/Multimode 2-Fiber Tester with 850/1300 nm LED and 1310/1550 nm laser
sources, optical power meter, and integrated 650 nm VFL; (2) SC source port adapter, (1)
SC meter port adapter, USB cable for data transfer; OTS-View software; Li-Ion rechargeable
battery and AC power adapter; (1) wrist strap and user’s manual

|
CONNECTORS
|
CABLES
|
PRETERMINATED SYSTEMS

SPECIFICATION SHEET LAN-942-EN | PAGE 9


|
OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities
A LANscape ®
Solutions Product

ordering information | (continued)


Part Number Description

Test Kits

OTS-600MD Multimode Test Kit with OS-403RD (850/1300 nm LED) source and integrated 650 nm VFL;
OM-610 power meter; (2) Li-Ion rechargeable batteries and (2) AC power adapters; USB
cable for data transfer; OTS-View software (1) SC source port adapter, (1) SC meter adapter,
(1) ST® Compatible meter adapter, (1) LC meter adapter, (2) wrist straps, cleaning supplies,
multimode testing mandrels, hard transit case and user’s manual

OTS-600SD Single-mode Test Kit with OS-404RXD (1310/1550 nm laser) source and integrated
650 nm VFL; OM-610 power meter; (2) Li-Ion rechargeable batteries and (2) AC power
adapters; USB cable for data transfer; OTS-View software (1) SC source port adapter,
(1) SC meter adapter, (1) ST Compatible meter adapter, (1) LC meter adapter, (2) wrist
straps, cleaning supplies, hard transit case and user’s manual

OTS-6MDSD Single-mode/Multimode Test Kit with OS-4RMDSD (850/1300 nm LED and 1310/1550 nm
laser) source and integrated 650 nm VFL; OM-610 power meter; (2) Li-Ion rechargeable batter-
ies and (2) AC power adapters; USB cable for data transfer; OTS-View software (1) SC source
port adapter, (1) SC meter adapter, (1) ST Compatible meter adapter, (1) LC meter adapter,
(2) wrist straps, cleaning supplies, multimode testing mandrels, hard transit case and user’s
manual

OTS-611MD Multimode OLTS Test Kit for bi-directional testing with (2) OT-611MD testers (850/1300 nm
LED) with integrated 650 nm VFL and power meter; (2) Li-Ion rechargeable batteries and
(2) AC power adapters; (2) USB cables for data transfer; OTS-View software (2) SC source
port adapters, (2) SC meter adapters, (2) ST Compatible meter adapters, (2) LC meter
adapters, (2) wrist straps, cleaning supplies, multimode testing mandrels, hard transit case
and user’s manual

OTS-612SD Single-mode OLTS Test Kit for bi-directional testing with (2) OT-612SD testers
(1310/1550 nm laser) with integrated 650 nm VFL and power meter; (2) Li-Ion
rechargeable batteries and (2) AC power adapters; (2) USB cables for data transfer;
OTS-View software (2) SC source port adapters, (2) SC meter adapters, (2) ST
Compatible meter adapter, (2) LC meter adapters, (2) wrist straps, cleaning supplies,
and hard transit case and user’s manual

OTS-613QD Single-mode/Multimode OLTS Test Kit for bi-directional testing with (2) OT-613QD testers
(850/1300 nm LED and 1310/1550 nm laser sources) with integrated 650 nm VFLs and power
meters; (2) Li-Ion rechargeable batteries and (2) AC power adapters; (2) USB cables for data
transfer; OTS-View software (4) SC source port adapters, (2) SC meter adapters, (2) ST
Compatible meter adapters, (2) LC meter adapters, (2) wrist straps, cleaning supplies,
multimode testing mandrels, hard transit case and user’s manual

SPECIFICATION SHEET LAN-942-EN | PAGE 10


OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities

|
A LANscape ®

TRAINING
Solutions Product

ordering information | (continued)

|
SPLICE EQUIPMENT
Part Number Description

Test Kits with Video Inspection Probe


OTS-600MD-P OTS-600MD Kit with Video Inspection Probe (VIP); includes bulkhead tip set for SC, FC and
universal 2.5 mm

|
OTS-600SD-P OTS-600SD Kit with Video Inspection Probe (VIP); includes bulkhead tip set for SC, FC and

TEST EQUIPMENT
universal 2.5 mm

OTS-6MDSD-P OTS-6MDSD Kit with Video Inspection Probe (VIP); includes bulkhead tip set for SC, FC and
universal 2.5 mm

OTS-611MD-P OTS-611MD Kit with Video Inspection Probe (VIP); includes bulkhead tip set for SC, FC and
universal 2.5 mm

|
SPLICE CLOSURES
OTS-612SD-P OTS-612SD Kit with Video Inspection Probe (VIP); includes bulkhead tip set for SC, FC and
universal 2.5 mm

OTS-613QD-P OTS-613QD Kit with Video Inspection Probe (VIP); includes bulkhead tip set for SC, FC and
universal 2.5 mm

|
HARDWARE
|
CABLE ASSEMBLIES
|
CONNECTORS
|
CABLES
|
PRETERMINATED SYSTEMS

SPECIFICATION SHEET LAN-942-EN | PAGE 11


|
OTS-600 Series Optical Sources, Meters,
Testers and Kits with Data Storage Capabilities
A LANscape ®
Solutions Product

ordering information | (continued)


Part Number Description

Accessories

VIPROBE-DUAL Video Inspection Probe for use with OTS-600; 200x/400x magnification with coaxial lighting;
includes bulkhead tips for SC, FC and universal 2.5 mm

UI-SC Universal Interface Source Connector Adapter, SC

UI-ST Universal Interface Source Connector Adapter, ST® Compatible Connector

UI-FC Universal Interface Source Connector Adapter, FC

OA-SC Power Meter Connector Adapter, SC

OA-ST Power Meter Connector Adapter, ST Compatible Connector

OA-FC Power Meter Connector Adapter, FC

OA-LC Power Meter Connector Adapter, LC

OA-MTRJ Power Meter Connector Adapter, MT-RJ

PS-9-1 AC Power Adapter for OS-400 Series (OS-403RD, OS-404RXD and OS-4RMDSD)

400-BATT-COVER OS-400 Series Battery Compartment Cover (OS-403RD, OS-404RXD and OS-4RMDSD)

400-OTS-BATT OS-400 Series Li-Ion Battery (OS-403RD, OS-404RXD and OS-4RMDSD)

PS-600 AC Power Adapter for OT-600 and OM-600 Series (OM-610, OT-613QD, etc.)

600-OTS-BATT OT-600 and OM-600 Series Battery (OM-610, OT-613QD, etc.)

CASE-HH-600 Hard-Shell Transit Case for (2) 600 Series instruments

OTS-COMBOMAN Set of Mandrels for loss testing of 50 µm and 62.5 µm multimode fiber

Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA


800-743-2675 • FAX: 828-901-5973 • International: +1-828-901-5000 • www.corning.com/cablesystems
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. LANscape is a
registered trademark of Corning Cable Systems Brands, Inc. ST is a registered trademark of Lucent Technologies. All other trademarks are the properties of their respective owners.
Corning Cable Systems is ISO 9001 certified. ©2008, 2009 Corning Cable Systems. All rights reserved. Published in the USA. LAN-942-EN / September 2009

SPECIFICATION SHEET LAN-942-EN | PAGE 12

You might also like