Datasheet

MA5801-GP08-H2 Product
Datasheet
The MA5801-GP08-H2 is a compact and low-density box-
shaped OLT. It provides multiple fiber to the home (FTTH)
solutions to meet the requirements of economical and efficient
network construction.

Issue: 03 Date: 2022-06-29

www.huawei.com
Product Overview
With the continuous promotion of new services, such as 4K/VR videos, home networks, and network cloudification, optical fiber
access has become an important means for countries around the world to popularize broadband networks. As optical fiber
access nodes keep moving closer to end users, OLTs are closer to end users. Deployment scenarios are complex and
diversified. In this case, network needs OLTs with small volume and low density.

The MA5801-GP08-H2 is a compact and low-density box-shaped OLT. It provides multiple fiber to the home (FTTH) solutions to
meet the requirements of economical and efficient network construction. It can be flexibly deployed in fast fixed mobile
convergence (FMC) scenario, national broadband coverage scenario, and enterprise's all-optical campus scenario.

Appearance and Structure


The product is a box-shaped OLT. It houses integrated control and service module, 1 pluggable fan module and 2 pluggable
power modules. Its mounting ears are applicable to IEC specifications and ETSI specifications, and are used in racks or
cabinets of different specifications.

MA5801-GP08-H2 Product Datasheet 2


Product Highlights
Lightweight and small size
The lightweight OLT weighs less than 5 kg and occupies 1 U installation space. It can be flexibly adapted to various scenarios.

Dual power supplies, high reliability


Supports dual AC or DC power supplies, providing flexible power supply and high reliability.

Easy installation and flexible deployment


The matching small outdoor cabinet can be installed on a pole, tower, or wall, facilitating installation and reducing engineering
costs.

Working Principle

⚫ Control module: It is the core of the system control and service switching and aggregation. It can also function as the
management and control core of the integrated network management system (NMS).
⚫ Upstream module: It can provides four 10GE/GE upstream ports.
⚫ Service processing module: It works together with the optical network unit (ONU) to provide GPON access services.
⚫ Interface module: It supports functions such as input and output of alarm digital parameters.

MA5801-GP08-H2 Product Datasheet 3


⚫ Power module: It supplies power to each functional module of the board.
⚫ Clock module: It provides clock signals for each functional module of the board.

External Ports

The product provides 2 slots for power boards so that 1 or 2 power modules can be configured as required. If only one power
module is configured, a filler panel must be installed in the other slot. AC and DC are incompatible.

Port Name Silk Screen Number Function


of Ports

DC power port – 2 Connects to –48/–60 V DC power.

AC power port – 2 Connects to 110/220 V AC power.

Reset button RESET 1 This button is used to reset the board manually. Resetting
the board interrupts the services. Hence, exercise caution
when using the reset button.

GPON port PON: 0–7 8 Provides 8 GPON ports for GPON service access.

Upstream port (10GE/GE 10GE/GE: 0– 4 Provides 4 10GE/GE ports for upstream transmission.
optical) 3

GE maintenance network port ETH 1 10/100/1000M BASE-T maintenance port. Connected to the
Ethernet port of the maintenance terminal.

RS-232 serial port/RS-485 CON/ESC 1 Connected to the serial port of the maintenance
monitoring serial port terminal/Connected to the serial port of the monitored device.

TOD port TOD 1 Reserved.

Environment monitoring port ALM 1 Connected to digital sensors.

Indicators
Indicator on The Panel Indicators
Indicator Name Color Status Description

RUN/ALM Running status indicator Green Blinking slowly (on for 1s The board functions properly.
and off for 1s repeatedly)

MA5801-GP08-H2 Product Datasheet 4


Indicator Name Color Status Description

Green Blinking quickly (on for Indicates that program loading is in


0.25s and off for 0.25s progress.
repeatedly)

Orange Blinking A high-temperature alarm is


generated.

Red On The board is faulty.

Red Blinking (on for 0.25s and The board is starting.


off for 0.25s repeatedly)

CRI Alarm indicators Red On The system has generated a


critical alarm.

MAJ Alarm indicators Orange On The system has generated a major


alarm.

MIN Alarm indicators Yellow On The system has generated a minor


alarm.

PON 0–7 Link/data status indicator Green On The ONT connected to the related
PON port is online.

Green Blinking The optical module does not take


effect.

- Off The ONT connected to the related


PON port is not offline.

- - Off Reserved

Indicator on The Upstream Port


Ports Indicat Name Color Status Description
or

Upstrea LINK Link status Green On A connection is set up on the port.


m optical indicator
port - Off No connection is set up on the port.

ACT Data status Yellow Blinking Data is being transmitted.


indicator
- Off No data is being transmitted.

Indicator on DC Power
Indicator Name Color Status Description

STAT Power indicator Green On The input/output is normal.

Green Blinking The power supply is in hiccup protection mode.

- Off The power input is abnormal (no input, input overvoltage


or undervoltage), and the power output is abnormal
(undervoltage, overvoltage, or short circuit).

Indicator on AC Power
Indicator Name Color Status Description

STAT Power indicator Green On The input/output is normal.

MA5801-GP08-H2 Product Datasheet 5


Indicator Name Color Status Description

Green Blinking The power supply is in hiccup protection mode.

- Off The power input is abnormal (no input, input overvoltage


or undervoltage), and the power output is abnormal
(undervoltage, overvoltage, or short circuit).

Indicator on Fan
Indicato Color Status Meaning Operation Description
r

STATUS Yellow Blinking (on for 0.25s and off The fan module is not If the fan module is not registered,
for 0.25s repeatedly) registered. no action is required.

Green Blinking (on for 1s and off for The fan module is No action is required.
1s repeatedly) normal.

Red Blinking (on for 0.25s and off The fan module is Replace the faulty fan module.
for 0.25s repeatedly) faulty.

Primary Features
Layer 2 features

VLAN+MAC forwarding SVLAN+CVLAN forwarding

PPPoE+ DHCP option82

Layer 3 features

Static route RIP/RIPng

OSPF/OSPFv3 IS-IS

BGP/BGP4+ ARP

DHCP relay VRF

Multicast

IGMP v2/v3 IGMP Proxy/Snooping

MLD v1/v2 MLD Proxy/Snooping

VLAN-based IPTV multicast IPv4 PIM and PIM-SSM

QoS

Traffic classification Priority processing

trTCM-based traffic policing WRED

Traffic shaping HQoS

PQ/WRR/PQ+WRR ACL

IPv6

IPv4/IPv6 dual stack IPv6 L2 and L3 forwarding

DHCPv6 relay

MA5801-GP08-H2 Product Datasheet 6


System reliability

GPON Type B/Type C protection ERPS (G.8032)

2 power boards for redundancy protection In-service board fault detection and rectification

Aggregation

Aggregation management

Product Specifications
Item Value

Dimensions (W x D x H) (mm) Excluding mounting ears: 442 x 220 x 43.6


Including IEC mounting ears: 482.6 x 220 x 43.6
Including ETSI mounting ears: 531 x 220 x 43.6

Maximum fully-loaded weight 5 kg

Power supply mode ⚫ DC power supply (dual backup)


⚫ AC power supply (dual backup)

Working voltage range ⚫ DC power supply: –38.4 V to –72 V


⚫ AC power supply: 100 V to 240 V

Rated voltage ⚫ DC power supply: –48 V/–60 V


⚫ AC power supply: 110 V/220 V

Maximum input current ⚫ DC power supply: 6 A


⚫ AC power supply: 2.5 A

Ambient temperature –40°C to +65°C


The device can start up at a lowest temperature of –25°C.
NOTE
The +65°C temperature refers to the highest temperature measured at the
air intake vent of a service subrack.

Ambient humidity 5%–95% RH

Atmospheric pressure 70–106 kPa

Altitude < 4000 m. The air density varies with the altitude and will affect the heat
dissipation of a device. Therefore, the working environment temperature of the
device varies with the altitude.

System switching capacity 110 Gbit/s

MAC addresses 32768

Access ONT 1024

IPv4 routing table 8192

IPv6 routing table 4096

ARP table 16384

Bit error rate (BER) in full load A BER smaller than 10 e-10 for a port that transmits data in full load

Upstream ports 4 GE/10GE

MA5801-GP08-H2 Product Datasheet 7


Item Value

Service ports 8 GPON

System reliability specifications System availability for the typical configuration: > 99.999%
Mean time between failures (MTBF): about 61 years
NOTE
Due to different network environments and different boards used by
devices, the preceding MTBF (61 years) of the MA5801 is only for
reference. The preceding values are only for reference. For details, contact
the related Huawei engineers.

Power consumption DC power supply:


⚫ Static power consumption: 46W
⚫ Typical power consumption: 64W
⚫ Maximum power consumption: 111W
AC power supply:
⚫ Static power consumption: 47W
⚫ Typical power consumption: 65W
⚫ Maximum power consumption: 112W
NOTE
The power consumption of a product is tested in the following conditions:
⚫ Static power consumption: 25°C, no optical module in optical ports, and
no service.
⚫ Typical power consumption: 25°C, 4 x 10GE(10kM) upstream ports, 8 x
GPON(CLASS C+) ports on the user side, full services, and maximum
traffic.
⚫ Maximum power consumption: 65°C, 4 x 10GE(10kM) upstream ports, 8
x GPON(CLASS C+) ports on the user side, full services, and maximum
traffic.

Supported Optical Modules


One-channel Two-fiber Bidirectional GE Optical Module
Type One-channel two-fiber bidirectional optical module

No. 1 2

Reach 10 km 40 km

Operating Wavelength 1310 nm 1310 nm

Encapsulation Type eSFP eSFP

Port Rate 1.25 Gbit/s 1.25 Gbit/s

Minimum Output Optical -9 dBm -5 dBm


Power

Maximum Output Optical -3 dBm 0 dBm


Power

Maximum Receiver -20 dBm -23 dBm


Sensitivity

Optical Connector Type LC LC

MA5801-GP08-H2 Product Datasheet 8


Optical Fiber Type Single-mode Single-mode

Overload Optical Power -3 dBm -3 dBm

Extinction Ratio 9 dB 9 dB

One-channel One-fiber Bidirectional GE Optical Module


Type One-channel one-fiber bidirectional optical module

No. 1 2 3 4

Reach 10 km 10 km 40 km 40 km

Operating Wavelength Tx: 1310 nm Tx: 1490 nm Tx: 1310 nm Tx: 1490 nm
Rx: 1490 nm Rx: 1310 nm Rx: 1490 nm Rx: 1310 nm

Encapsulation Type eSFP eSFP eSFP eSFP

Port Rate 1.25 Gbit/s 1.25 Gbit/s 1.25 Gbit/s 1.25 Gbit/s

Minimum Output Optical -9 dBm -9 dBm -2 dBm -2 dBm


Power

Maximum Output Optical -3 dBm -3 dBm 3 dBm 3 dBm


Power

Maximum Receiver -19.5 dBm -19.5 dBm -23 dBm -23 dBm
Sensitivity

Optical Connector Type LC LC LC LC

Optical Fiber Type Single-mode Single-mode Single-mode Single-mode

Overload Optical Power -3 dBm -3 dBm -3 dBm -3 dBm

Extinction Ratio 6 dB 6 dB 9 dB 9 dB

One-channel Two-fiber Bidirectional 10GE Optical Module


Type One-channel two-fiber bidirectional optical module

No. 1 2 3

Reach 0.3 km 10 km 40 km

Operating Wavelength 850 nm 1310 nm 1550 nm

Encapsulation Type SFP+ SFP+ SFP+

Port Rate 10 Gbit/s 10 Gbit/s 9.95-11.1 Gbit/s

Minimum Output Optical -7.3 dBm -8.2 dBm -4.7 dBm


Power

Maximum Output Optical -1 dBm 0.5 dBm 4 dBm


Power

Maximum Receiver -9.9 dBm -12.6 dBm -14.1 dBm


Sensitivity

Optical Connector Type LC LC LC

Optical Fiber Type Multi-mode Single-mode Single-mode

Overload Optical Power -1 dBm 0.5 dBm 0.5 dBm

MA5801-GP08-H2 Product Datasheet 9


Extinction Ratio 3 dB 3.5 dB 3 dB

One-channel One-fiber Bidirectional 10GE Optical Module


Type One-channel one-fiber bidirectional optical module

No. 1 2 3 4

Reach 10km 10km 40km 40km

Operating Tx:1270nm Tx:1330nm Tx:1330nm Tx:1270nm


Wavelength Rx:1330nm Rx:1270nm Rx:1270nm Rx:1330nm

Encapsulation Type SFP+ SFP+ SFP+ SFP+

Port Rate 2.5Gbit/s–11.3Gbit/s 2.5Gbit/s–11.3Gbit/s 9.95Gbit/s–10.3Gbit/s 9.95Gbit/s–10.3Gbit/s

Minimum Output -8.2dBm -8.2dBm 0dBm 0dBm


Optical Power

Maximum Output 0.5dBm 0.5dBm 5dBm 5dBm


Optical Power

Maximum Receiver -14.4dBm -14.4dBm -18dBm -18dBm


Sensitivity

Optical Connector LC LC LC LC
Type

Optical Fiber Type Single-mode Single-mode Single-mode Single-mode

Overload Optical 0.5dBm 0.5dBm -9dBm -9dBm


Power

Extinction Ratio 3.5dB 3.5dB 3.5dB 3.5dB

GPON Optical Module


Type One-fiber bidirectional optical One-fiber bidirectional optical One-fiber bidirectional optical
module, class B+ module, class C+ module, class C++

No. 1 2 3

Operating Tx: 1490 nm Tx: 1490 nm Tx: 1490 nm


Wavelength Rx: 1310 nm Rx: 1310 nm Rx: 1310 nm

Encapsulation SFP SFP SFP


Type

Port Rate Tx: 2.488 Gbit/s Tx: 2.488 Gbit/s Tx: 2.488 Gbit/s
Rx: 1.244 Gbit/s Rx: 1.244 Gbit/s Rx: 1.244 Gbit/s

Minimum 1.5 dBm 3 dBm 6 dBm


Output Optical
Power

Maximum 5 dBm 7 dBm 10 dBm


Output Optical
Power

Maximum -28 dBm -32 dBm -35 dBm


Receiver
Sensitivity

MA5801-GP08-H2 Product Datasheet 10


Optical SC SC SC
Connector
Type

Optical Fiber Single-mode Single-mode Single-mode


Type

Overload -8 dBm -12 dBm -15 dBm


Optical Power

Extinction 8.2 dB 8.2 dB 8.2 dB


Ratio

MA5801-GP08-H2 Product Datasheet 11


Copyright © Huawei Technologies Co., Ltd. 2022. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of
Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or
part of the products, services and features described in this document may not be within the purchase scope or the usage
scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are
provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this
document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not
constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.

Address:Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China

Website:www.huawei.com

MA5801-GP08-H2 Product Datasheet 12

You might also like