Ingersoll Rand Air Filter Operating Manual
1. Safety
1.1.Do not use the filter at higher than its rated inlet pressure;
1.2.Prior to maintenance/service, makes sure all pressure is released.
2. Technical Specifications
Operating pressure:0.7MPa;Operating inlet temperature:<80℃;
Capacity Dimensions mm Weight
Model Connection size Drain
m3/min m3/hr H W (kg)
FV42* 0.7 42 0.5" BSPT 225 89 0.9 Rc1/4
FV72* 1.2 72 0.5" BSPT 225 89 0.9 Rc1/4
FV108* 1.8 108 0.5" BSPT 258 89 1 Rc1/4
FV216* 3.6 216 0.75" BSPT 333 120 2.4 Rc1/4
FV294* 4.9 294 1" BSPT 432 120 2.9 Rc1/4
FV342* 5.7 342 1" BSPT 432 120 2.9 Rc1/4
FV390* 6.5 390 1.5" BSPT 432 120 3 Rc1/4
FV444* 7.4 444 1.5" BSPT 432 120 3 Rc1/4
FV540* 9 540 1.5" BSPT 432 120 3 Rc1/4
FV690* 11.5 690 2" BSPT 521 162 5.1 R1/2
FV810* 13.5 810 2" BSPT 521 162 5.1 R1/2
FV990* 16.5 990 2" BSPT 845 160 6.5 R1/2
FV1050* 17.5 1050 2" BSPT 845 160 6.6 R1/2
FV1170* 19.5 1170 2" BSPT 845 160 6.6 R1/2
FV1380* 23 1380 2.5" BSPT 601 200 8.7 R1/2
FV1590* 26.5 1590 2.5" BSPT 601 200 8.7 R1/2
FV1740* 29 1740 2.5" BSPT 601 200 8.7 R1/2
FV2100* 35 2100 3" BSPT 862 200 11 R1/2
FV2340* 39 2340 3" BSPT 862 200 11 R1/2
FV2700* 45 2700 4"FLG 900 470 66 Rc1/2
FV3090* 51.5 3090 5"FLG 900 470 98 Rc1/2
FV3480* 58 3480 5"FLG 900 470 103 Rc1/2
FV4080* 68 4080 5"FLG 930 520 118 Rc1/2
FV4200* 70 4200 5"FLG 930 520 120 Rc1/2
FV4560* 76 4560 5"FLG 930 520 120 Rc1/2
FV4800* 80 4800 6"FLG 930 520 123 Rc1/2
1
Ingersoll Rand Air Filter Operating Manual
3. Installation
3.1.Prior to installation, use compressed air to blow through piping to clear any
debris.
3.2.Connect the correct size pipe to the filter inlet/outlet ports.
3.3.Make certain that the filter piping is installed horizontally, with the filter body
perpendicular to the ground for proper filter function.
3.4.The air flow direction in the piping should adhere to the arrows on the filter.
3.5. It is best to install on both ends of the filter bypass valves in order to minimize
downtime when filter elements need to be changed.
3.6. Ensure the drainage is flowing to a gutter, avoiding water and oil contaminating
the work area.
2
Ingersoll Rand Air Filter Operating Manual
4. Operation
Note:When reducing system pressure, do so slowly to avoid damage to filter
components
4.1. When the filter is experiencing high pressure drop, or when exceed 4000 hrs
usage time (or one year normal operation), replace the filter element.
4.2.If the outlet pressure experiences sudden pressure drop, inspect the O-ring
gasket, drain and piping connection for leakage.
4.3.Inspect and make sure that the air flow, pressure, and temperature are all within
filter design parameters.
4.4.Inspect and make sure that the filter drain is functioning normally.
5. Maintenance
Warning: Air filter is a pressure bearing device, prior to all
service/maintenance, release all system pressure.
5.1.Filter element replacement procedure:
5.1.1.Open bypass valves, and trigger filter pre and after isolation valves
5.1.2.Slowly open manual drain port, release pressure
5.1.3.Aluminum alloy filter housing: unscrew bottom mount from top. Carbon steel
filters: loosen bolts on top flange.
5.1.4.Remove filter housing, replace the filter element by screw
5.1.5.Re-assemble filter housing
Note: O-ring gasket or flange gasket need to be replaced to prevent leakage.
5.2.Filter auto drain: Inspect and clean every week to avoid blockage.