Cat 2c E Insulated Conductor Systems U15 U25 U35
Cat 2c E Insulated Conductor Systems U15 U25 U35
Cat 2c E Insulated Conductor Systems U15 U25 U35
CONDUCTOR SYSTEMS
U 15 – U 25 – U 35
19 12
INSULATED CONDUCTORS U 15 – U 25 – U 35
Index U 15 U 25 U 35
Page Page Page
Basic description 4 4 4
Selection of conductors 5 5 5
Insulated conductors 5 23 34
Joint splices 6 23 34
Expansion sections 6 24 35
Feed terminals 6 24 35
Locating clamps 7 24 36
Insulated hangers 7 25 36
Rail holders 7 25 36
Insulators 7 25 36
Compact hangers, bracket profiles 7 26 –
Attachment hardware 8 26 –
Transfer guides 8, 9 26 37
Sectionalizing 9 25 34
End caps 9 25 34
Transfer funnels 10, 11 28 –
Collectors 11 – 14 27 38, 39
Connecting cables 15 – –
Collector brackets, Cable attachment clamp 16 28 38
Contact grease 15 28 36
Components for collectors, Spare parts 16 – 18 29 – 31 40, 41
Brush wear indicator 19 – –
Brackets, Snap-on brackets, Mounting brackets 20 33 –
Examples for ordering, Arrangement 21 32 42
Installation tools 22 – –
Earthing spider system – 43 43
Questionnaire 44, 45 44, 45 44, 45
Application photos 2, 5
Collector rings with insulated conductors see leaflet No. 102.
2
INSULATED CONDUCTORS U 15 – U 25 – U 35 19 12
GENERAL
SELECTION OF CONDUCTORS
ENGINEERING DATA
Pages 4 – 5
U 15
For light cranes and hoists/elevators, self-propelled monorail
carriers, automated storage and retrieval systems, assembly
and test tracks, motor powered gates and doors, for all kinds
of data and signal transmission, etc
Ampacity up to 100 A
Pages 5 – 22
U 25
For bridge- and portal crane electrification, stacker cranes,
heavy monorail systems, amusement & rapid transit rides,
construction- and maintenance lifts etc. – Ampacity up to
450 A
Pages 23 – 33
U 35
Applications as U 25;
however for heavy duty – Ampacity up to 1250 A
Pages 34 – 42
Questionnaire
Pages 44, 45
3
19 12
INSULATED CONDUCTORS U 15 – U 25 – U 35
General Joint splices
VAHLE insulated conductors U 15, U 25 and U 35 are designed Bolted joint splices are designed to rigidly join conductor bars
in accordance with today’s international safety requirements. and provide mechanical and electrical continuity. They include
They fully meet VDE 0100 and are finger safe to VDE 0470, part insulated protection covers.
1, protection code IP 23.
Expansion joint sections must be provided for high temperature
The adjacent picture demonstrates that the fluctuation and for system runs exceeding 100 m for U 15
VDE test finger cannot reach live conductors (150 m for U 25 / U 35) – see installation procedure.
– finger safety is guaranteed.
The shroud which envelopes the various Feed terminals
conductors is an excellent insulator. Therefo-
Feed terminal sets are preferably installed at conductor joints.
re our unipole insulated conductors guaran-
Adequate single core feed cables must be provided for
tee utmost safety in operation.
connection of the incoming power.
Any number of conductors can be installed
side by side at minimum space requirement.
End caps
Standard rail sections U 15, U 25 are 6 m
The open ends of unipole conductors are closed by end caps.
and U 35, 6.25 m long.
Shorter sections are available.
The ground conductor is identified by international colour Transfer funnels and Transfer guides
coding. Single pole and multi pole transfer guides are available for
spurlines, turntables and switches or other tranfer applications.
For obvious safety reasons phase and ground collectors are
not interchangeable.
Isolating sections
Approved and listed by Conductor isolating sections are available for sectionalizing
U 15: SEV and CSA, control circuits, maintenance bays etc.
U 25: UL
Consult factory label service.
Curves
Hangers Factory fabricated or field prepared radius bends can be used
Snap-on or bolt-on brackets can be used to install conductors for horizontal or vertical curves.
to the runway track. Spacing between rail supports:
U 15: see page 11, Collectors
U 25: see page 23,
U 35: see page 40. The current collectors are made of re-inforced polyamide/poly-
carbonate and stainless steel parts. These spring loaded units
provide positive contact with the conductor bars and have one
Insulators
or two pickup-shoes.
Insulators are recommended for difficult environmental conditi- The collector of the AE-Conductor which are working with only
ons (extreme humidity, chemicals etc.) > 10 m/min. travel speed or stand most of the time are only
permitted to work with 150 % of the continuous current.
Engineering data of shroud
standard high temp.
Resistance to chemicals:
shroud shroud
color green color gray Gasoline stable
Electrical properties: Mineral oil stable
Di-electric strength DIN 53481 30-40 45
kV/mm kV/mm Grease stable
Specific resistance DIN 53482 5 x 10 15 5 x 10 17 Caustic soda 25 % stable
Ohm/cm Ohm/cm Caustic soda 50 % stable
Surface resistance DIN 53482 1013 1015
Ohm Ohm Hydrochloric acid, concentrated stable
Leakage resistance Sulphuric acid up to 50 % stable
CTI 600-1.1 CTI 600-1.1
IEC 1112 / VDE 0303
Mechanical properties
75 N/mm2 95 N/mm2 Please consult factory for galvanizing plants, pickling
Flexible strength lines, other aggressive or deep freeze ambients, as well
± 10% ± 10%
as low voltage and data transmission applications, indi-
Tensile strength 50 N/mm2 50 N/mm2 cating special environmental conditions.
± 10% ± 10%
To speed up quotations and order processing, we would
Ambient –30° C to –30° C to appreciate receiving your drawings or sketches for
temperature +55° C +85° C systems with curves, dead sections, turntables, swit-
Flame test proof per class B1 ches, etc.
DIN 4102 no flaming particles, Please use our questionnaire, pages 44 and 45.
part 1 self-extinguishing
4
INSULATED CONDUCTORS U 15 19 12
U 15/25 C U 15/25 E
Weight kg/m 0.295 0.285
Standard shroud, color green
Cat-No. phase(1) 162 13 • 162 15 •
Cat-No. ground(1) 162 19 • 162 21 •
High temperature shroud, color gray
Cat-No. phase(1) 162 16 • 162 18 •
Cat-No. ground(1) 162 22 • 162 24 •
Engineering Data
Conductor Rail Cross sectional area Leakage distance max. Impedance Ohm/1000 m
continuous based on 50 Hz & conductor spacing
Type mm2 Resistance
of shroud voltage amp. capacity
Ohm/1000 m
Cu stainless steel mm V A 18 mm 25 mm 50 mm
U 15/25 C 25 30 660 100 0.692 0.698 0.701 0.709
U 15/25 E 25 30 660 10 29.077 29.077 29.077 29.077
Selection of conductors
in accordance to ampere load and environmental conditions
U 15/25 C copper conductor for power and control system applications
U 15/25 E stainless steel conductor for control and data-transmission in corrosive atmospheres
New material handling techniques (automated overhead monorails) require reliable electrification and use U 15 conductors.
(1) Add last number (1, 2, 3, 4, 5 or 6 m length suffix) in accordance to bars required.
(2) Recommendation
5
19 12
ACCESSORIES FOR U 15
Bolted joint splice
applicable as feed terminal, too.
28
10
80
21
21 17
Corresponding to UE 15 K 4
Expansion sections
factory assembled on 1 m long conductor section incl. one joint splice.
The 1 m expansion assembly is part of the system length.
(29)
36
(10)
17
96 30
16 dim. on parenthesis
refer to UDVN max. expansion = 30 mm
Feed terminals
16
10
17
M5
29
34
80 100
42
42
max. 8
locating clamps for an
anchor point
25
10
17
34
16
16
16
18
cantilever = 3000 N
creapage distance = 60 mm M 6 x 11 deep
28
Bracket profiles 28/12
incl. locking hardware
2
12
Length Weight
Type for poles Cat.-No.
mm kg
HU 15/200 200 6+ 7 0.130 161 434
HU 15/330 330 12 +14 0.300 161 435
M6
12 Longer brackets furnished on special order.
max. 12 mm
Bracket
D
d
d D S Cat.-
Type Weight kg Cat.-No. Type Thread Weight kg
mm mm mm No.
Hardware set BE 5 K 4(1) 0.001 161 441 Washer 5.3 K 4(1) M5 5.30 15 1.60 0.002 161 408
d.
con
w/o w/o feed US 15 TS
20
65
Conductor
24 surface /
track
US 15 TS
(USE 15 TS)
max. gap between opposite transfer guides:
L. H. switch
6 mm for straight transfers
10 mm for oblique transfers
80
A
Dim. A
Type poles Weight kg Cat.-No.
mm
BFU 15 B-6 1 to 6 116 0.095 160 851 (Distance between conductor sliding surface and track = 24 mm;
BFU 15 B-8 1 to 8 152 0.120 160 852 corresponds to compact hanger KA 15/6)
Transfer guides
(no anchor point function) max. gap between opposite transfer guides 6 mm
max. vertical and horizontal offset ± 2 mm
10
US 15 w/o 0.010 160 125
USE 15 c/w 0.050 160 126
separately available:
0.040 160 859
16
Isolating sections
Length of
Type(1) Weight kg Cat.-No.
A isolating piece A
Isolating assemblies
2 x LT/ U 15
LT / LTE - U 15 0.034 160 845
9 1 x flat plug
.
→
→
c ond 2 x LT/ U 15
w/o LTE / LTE - U 15 0.036 160 846
2 x flat plug
43
ca. 680
24 for KA15/6 = 84
17 for KA15/7 = 91
20
9,4°
82
20 (w/o cond.)
35
max. 800
665 w/o cond.
18 18 18 18 18
C
D
B
slotted hole 7 x 15
40
375 65
615
24 for KA15/6 = 84
17 for KA15/7 = 91
120
10,4°
max. 800
D
B
65
slotted hole 7 x 15
40
250 100
10
335
Transfer funnels for KSFU 25
59
for max. speed v = 100 m/min.(1)
85
15°
24
max. 800
320 w/o cond.
64
Type A mm B mm C mm D mm Weight kg Cat.-No. 154
18 1818 1818
EFT U 15-4 - KSFU 80 138 126 180 1.520 161 631
C
A
B
D
EFT U 15-5 - KSFU 98 156 144 198 1.640 161 632
EFT U 15-6 - KSFU 116 174 162 216 1.760 161 633
EFT U 15-7 - KSFU 134 192 180 234 1.880 161 634
EFT U 15-8 - KSFU 152 210 198 252 2.000 161 635
35
Collectors
c/w 2 m cable; contact pressure ca. 5 N
13,5 (17,8 KSTU) A
85 4,4
60
85 (95)
Picture 1
12
140 (190)
A < 300 mm conductor support spacing 0.8 m
A > 300 mm conductor support spacing 1.0 m
Connecting cable Lift & Weight Cat.-No.
Ampacity swivel kg
Type(2) A A/ D max/ phase- ground
mm2 mm A mm black yellow
KST 30 30 2.50 5 ± 20 0.240 152 085 152 086
KST 55 55 6.00 11 ± 20 0.368 154 438 154 439
KSTL 30 30 2.50 5 ± 30 0.240 152 089 152 091
KSTL 55 55 6.00 11 ± 30 0.368 154 443 154 444
KSTU 30 (3) 30 2.50 5 ± 20 0.240 152 087 152 088
KSTU 55 (3) 55 6.00 11 ± 20 0.368 154 441 154 442
ZF 1
60
plug
terminal
70
Lift ±10 mm,swivel ±15 mm, contact pressure: ca. 3 N Lift ±10 mm, swivel ±10 mm, contact pressure: ca. 3.5 N
Connecting cable to be ordered separately. Connecting cable to be ordered separately.
Type(1) Ampacity Cat.-No. Type(1) Ampacity Cat.-No.
Weight kg Weight kg
A phase - black ground - yellow A phase - black ground - yellow
KST 20 20 0.050 155 071 155 072 KST 25 25 0.060 155 013 155 014
plug
terminal
6.3 x 0.8
Lift ±10 mm, swivel ±10 mm, for WFLA 2.5
80
contact pressure: ca. 3.5 N per brush plug ZF 2
terminal
Connecting cable to be ordered seperately. 6.3 x 0.8
for FLA 2.5
Cat.-No. or WFLA 2.5
Type (1) Weight kg
phase - black ground - yellow
M 5, phase
KST 2/40 0.080 168 137 168 138 ca. 70 M 6, ground
max. 138
Compact current collectors(2) 8
7
6
max. ampacity: 1 flat plug 25 A 18
5
4
3
2
1 RF 3
For conductor spacing of 18 mm;
8
Lift & swivel ± 15 mm
.1
ax
Contact pressure:
m
ca. 3.5 N per brush
Ground at No. 4, 3-pole at No. 3 DF 2
other position on request. c
88
For safety reasons during a
plug b
maintenance ground collector is terminal 15 15
6.3 x 0.8 42
always first and last contact. for FLA 2.5
7 71
or WFLA 2.5
Cat.-No.
Type (1) a b c Weight
Base plate
Poles for power incl. 1 x ground for control
mm mm mm kg
HS ST
max. 127
Compact current collectors 8
7
6
5
max. ampacity: 1 flat plug 32 A - FLA 2,5 4
3
40 A - FLA 4,0 14
2
1
55 A - FLA 6,0
RF 3
For conductor spacing of 18 mm;
Lift & swivel ± 15 mm
Contact pressure: . 18
max
ca. 3.5 N per brush
DF 2
Ground at No. 4, 3-pole at No. 3
53
plug
*
a
88
terminal
For safety reasons during 6.3 x 0.8 15
15
for FLA
maintenance ground collector is 7 42
71
always first and last contact.
Cat-No.
(1) Poles a b c Weight
Type Base plate for power incl. 1 x ground for control
mm mm mm kg
HS ST
KESR 32-55-1-18 1 54 79 - 0.194 4pole (No. 2 - 4 = blank) 155 201 –
KESR 32-55-2-18 2 54 79 - 0.264 4pole (No. 3 + 4 = blank) 155 202 155 209
KESR 32-55-3-18 3 54 79 - 0.334 4pole (No. 4 = blank) 155 203 155 210
KESR 32-55-4-18 4 54 79 - 0.404 4pole 155 204 155 211
KESR 32-55-5-18 5 80 115 53 0.525 6pole ( No. 6 = blank) 155 205 155 212
KESR 32-55-6-18 6 80 115 53 0.595 6pole 155 206 155 213
KESR 32-55-7-18 7 120 151 80 0.721 8pole (No. 8 = blank) 155 207 155 214
KESR 32-55-8-18 8 120 151 80 0.791 8pole 155 208 155 215
Separately available: phase black ground yellow
Collector KESR 32-55, 1pole 0.070 w/o 168 304 168 305
12 (1) Suffix types e.g.: KST 25 KST 25 PH, Cat.-No. 155 013 KSF 25-3 KSF 25-3 HS, Cat.-No. 155 028
(2) Install collectors in dragging position when equipment moves over transfer guides.
COMPACT CURRENT COLLECTORS FOR U 15 19 12
8
.1
other position on request.
ax
m
For safety reasons during
maintenance ground collector is
always first and last contact.
88
c DF 2
plug b a
terminal
6.3 x 0.8 15
15
for WFLA 2.5 7 42
71
DF 1
53
98
14
a
b
15
42
7
71
Cat.-No.
(1) Poles a b c Weight
Type Base plate for power incl. 1 x ground for control
mm mm mm kg
HS ST
KDS 2/40-1-18 1 54 79 - 0.194 4pole (No. 2 - 4 = blank) 155 077 155 089
KDS 2/40-2-18 2 54 79 - 0.264 4pole (No. 3 + 4 = blank) 155 078 155 090
KDS 2/40-3-18 3 54 79 - 0.334 4pole (No. 4 = blank) 155 079 155 091
KDS 2/40-4-18 4 54 79 - 0.404 4pole 155 080 155 092
KDS 2/40-5-18 5 80 115 53 0.525 6pole ( No. 6 = blank) 155 081 155 093
KDS 2/40-6-18 6 80 115 53 0.595 6pole 155 082 155 094
KDS 2/40-7-18 7 120 151 80 0.721 8pole (No. 8 = blank) 155 083 155 095
KDS 2/40-8-18 8 120 151 80 0.791 8pole 155 084 155 096
Separately available: phase-black ground-yellow
Collector KDS 2/40, 1pole 0.070 w/o 168 073 168 074
(1) Suffix types e.g. KSFU 25-2 KSFU 25 - 2 HS, Cat.-No. 155 050 · KDS 2/40 -1 -18 KDS 2/40 -1 -18 HS, Cat.-No. 155 077
13
19 12
COLLECTORS FOR U 15
Current collectors Double current collectors
17
100 4
100 200
75 100
75
65
65
12
12
c/w 2 m cable · lift & swivel ± 20 mm c/w 2 x 2 m cable · lift & swivel ± 20 mm
contact pressure: 9 N contact pressure: 9 N per brush
Am- Connecting cable Cat.-No. Am- Connecting cable Bestell-Nr.
Typ e(1) pacity Ø max/ Weight phase - ground - Typ e(1) pacity Ø max/ Weight phase - ground -
A mm2 mm kg black yellow A mm2 mm kg black yellow
KST 15 15 2.50 8.00 0.256 150 891 150 892 KDST 30 30 2.50 8.00 0.471 150 897 150 898
KST 40 40 6.00 11.00 0.428 152 840 152 850 KDST 80 80 6.00 11.00 0.821 152 960 152 970
KST 60 60 10.00 12.50 0.588 153 675 153 676 KDST 120 120 10.00 12.50 1.114 153 679 153 680
85
85
12 12
c/w 2 m cable · lift & swivel ± 40 mm c/w 2 x 2 m cable · lift & swivel ± 40 mm
contact pressure: 9 N contact pressure: 9 N per brush
Am- Connecting cable Cat.-No. Am- Connecting cable Cat.-No.
Typ e(1) pacity Ø max/ Weight phase - ground - Typ e(1) pacity Ø max/ Weight phase - ground -
A mm2 mm kg black yellow A mm2 mm kg black yellow
KSTL 15 15 2.50 8.00 0.272 150 893 150 894 KDSTL 30 30 2.50 8.00 0.492 150 899 150 901
KSTL 40 40 6.00 11.00 0.453 152 860 152 870 KDSTL 80 80 6.00 11.00 0.822 152 980 152 990
KSTL 60 60 10.00 12.50 0.591 153 677 153 678 KDSTL 120 120 10.00 12.50 1.188 153 681 153 682
Current collectors for transfer funnel EFT(2) Double current collectors for transfer funnel EFT(2)
304
152
spring released height
152 100
spring released height
100 17 75
75 4
env. 135
ca. 135
85
85
env.50
12
env. 50
12
FH
Cat.-No.
Type Cross section Outer Ø Weight
phase - ground -
mm2 mm kg
black yellow
FLA 4 0.080 165 049 165 050
FLA 2.5 2.50
FLA 4 4.00 6 0.100 165 051 165 052
WFH 4 0.080 168 107 168 108
WFLA 2.5 2.50
18
600
46
Collector bracket
for KST 15 thru KDSTLU 120 collectors, for KST 30 thru KSTLU 55 collectors, for control collectors only
see page 14 see page 11
30
40 mm wide
30 x 11
slotted hole
170
90
18
12
30
15
65
UMAS 12 HS -A 0.600 152 233 UMAS 12 HS -B 0.600 152 232 UMAS 12 ST 0.600 152 234
Contact Grease
for joints and feeds
20 g for approx. 40 joints Cat.-No. 120 016
421 g for approx. 1000 joints Cat.-No. 120 017
75 75 35
60 60
10
10
10
19
RH
RH
RH
ground-identification
102
66 66 85
50 35
50
10
10
10
23
23
23
RH
RH
RH
102
100 100
85
GF 1 35 GF 1 75 75
10
10
10
23
RH
RH
RH
DSW 2/40 DS 2/40 KMK 60 KMK 60 U
RH Weight
Type for collectors width of carbon brushes mm Cat.-No.
mm kg
S S
Springs
D
D
L L
Pressure spring DF
Guiding spring GF Tension spring ZF/RF
S D L
Type for collectors Cat.-No.
mm mm mm
ZF 1 KST 20, KST 25 0.63 5.40 22.00 153 514
ZF 2 KST 2/40 0.85 6.45 24.00 153 515
ZF 3 KST 15 to KDST 120 1.10 10.80 28.50 153 516
ZF 4 KSTL 15 to KDSTL 120 & KSTLU 15 to KDSTLU 120 1.30 11.00 29.00 153 517
DF 1 KSFR 2/40 1.00 7.00 38.00 153 847
DF 2 KSF 25 0.90 7.70 43.00 153 848
DF 3 KDS 2/40 0.55 9.55 24.00 152 011
RF 3 KSF 25, KSFR 2/40 0.40 4.40 31.00 153 849
GF 1 KSFR 2/40 0.35 2.00 22.00 153 850
(1) Also spare part for collector KSFR 2/40 (old type)
16 (2) 18 mm wide
COLLECTOR COMPONENTS FOR U 15 19 12
1 Collector base for KST 15 thru KST 60 phase PH 0,080 153 736
2 Collector base for KST 15 thru KST 60 ground PE 153 737
3 Collector base for KDST 30 thru KDST 120 (double arm) phase PH 0,100 153 738
4 Collector base for KDST 30 thru KDST 120 (double arm) ground PE 153 739
5 Collector base for KSTL 15 thru KSTL 60 phase PH 0,090 153 740
6 Collector base for KSTL 15 thru KSTL 60 ground PE 153 741
7 Collector base for KDSTL 30 thru KDSTL 120 (double arm) phase PH 0,130 153 742
8 Collector base for KDSTL 30 thru KDSTL 120 (double arm) ground PE 153 743
9 Collector base for KSTLU 15 thru KSTLU 60 phase PH 0,090 153 804
10 Collector base for KSTLU 15 thru KSTLU 60 ground PE 153 805
11 Collector base for KDSTLU 30 thru KDSTLU 120 (double arm) phase PH 0,130 153 806
12 Collector base for KDSTLU 30 thru KDSTLU 120 (double arm) ground PE 153 807
13 Connecting cable AEA 2,5 PH, 2 m long Phase PH 0,072 151 374
Connecting cable AEA 2,5 PE, 2 m long ground PE 151 375
13 Connecting cable AEA 6 PH, 2 m long Phase PH 0,260 153 744
Connecting cable AEA 6 PE, 2 m long ground PE 153 745
13 Connecting cable AEA 10 PH, 2 m long Phase PH 0,400 153 746
Connecting cable AEA 10 PE, 2 m long ground PE 153 747
14 Gummifeder(1) für KSTLU 15, KSTLU 40, KSTLU 60, KDSTLU 30 0,008 153 748
KDSTLU 80, KDSTLU 120
a
c
e
d
b
f
g
h
i
k
m
j l
n
(1) Rubber spring will be included when ordering KMK 60 U brush.
17
19 12
COLLECTOR COMPONENTS FOR U 15
For KST 30-55 thru KSTLU 30-55
Weight
Part.-No. Description Cat.-No.
kg
➆ ➁
➄ ➂
➈
➃
➅
18
BRUSH WEAR INDICATOR FOR U 15 19 12
Brush wear indicator KVT 15 N The brush wear indicator automatically checks the wear of
carbon brushes. The indicator is infinitely variable to the wearing
height of carbon brushes. A worn down carbon brush actuates
an impulse. It is recommended to place the indicator near a
maintenance area in order to open automatically a switch leading
the monorail hoist to the repair zone.
19
19 12
BRACKETS · SNAP-ON BRACKETS FOR U 15
Snap-on brackets facilitate installation of Powerails on flat flange beams PE, PB, PBI and PBv.
They are adjustable to suit beam flange dimensions (tg) of up to 43 mm.
18
3, 4 C
ø 5.5
Type Dim. A Dim. B Dim. C
mm mm mm
30
KH 15/2 36 96 –
24
50 Compact hanger
KH 15/3 74 114 –
KA 15/2 to 6 pol. KH 15/4 72 132 36
x 18
A
KH 15/5 90 150 36
Support bracket HKU…
KH 15/6 108 168 72
20
EXAMPLES FOR ORDERING U 15 19 12
Compact Configuration, 124 m, 5-pole + ground electrification system for 100 Amps.
100 VAHLE unipole insulated conductors, 6 m long phase U 15/25 C-6 162 136
5 VAHLE unipole insulated conductors, 2 m long phase U 15/25 C-2 162 132
20 VAHLE unipole insulated conductors, 6 m long ground U 15/25 C-6 162 196
1 VAHLE unipole insulated conductor, 2 m long ground U 15/25 C-2 162 192
18 VAHLE unipole insulated conductors, 6 m long phase U 15/25 E-6 162 156
3 VAHLE unipole insulated conductors, 4 m long phase U 15/25 E-4 162 154
6 VAHLE unipole insulated conductors, 6 m long ground U 15/25 E-6 162 216
1 VAHLE unipole insulated conductor, 4 m long ground U 15/25 E-4 162 214
21
19 12
INSTALLATION TOOLS FOR U 15
Curve tool
Details for vertical and horizontal curves see bending procedure
(installation procedure U 15).
Motor powered tool furnished on special order.
Filler rod is to be ordered separately.
C
Drill jig B
20
The drill guide should be used when conductor ends have to be A
A
prepared for end caps or transfer guides on site.
Drill B and D for end caps.
20
Drill B for transfer guide US 15 and USE 15.
81
Type Weight kg Cat.-No.
Punch tool
To prepare square holes in the shroud
for types US 15 T thru USE 15 TS transfer guides
and LT/LT-U 15 thru LTE/LTE-U 15 isolating assemblies.
22
INSULATED CONDUCTORS U 25 19 12
23
Conductor code: Support spacing:
19
U = unipole insulated conductor - for straight runs &
25 = shroud size for inside & outside curves: 1500 mm
U 25 C
12
- horizontal curves:
AE = Aluminium conductor contact
above RH = 10 m(2): 1500 mm
15
7
8
Length: Curves:
6 m is standard length, factory prepared from R = 800 mm
RH Radius
Horizontal curve shorter lengths are available or in the field
23 horizontal curves: from R = 7000 mm
19 inside & outside curves: from R = 2500 mm
Conductor spacing: AE-conductor on request.
U 25 AE on standard hangers 50 – 80 mm
12
on compact hangers 50 mm
Heating system available on request.
Chemical and electrical properties
27
Engineering data
Leakage max. max. Impedance(3) Ohm/1000 m
Conductor Rail Cross sectional area Resistance
distance of covers voltage Amp. capacity based on 50 HZ & conductor spacing
Typ2 mm2 Ohm/1000 m
mm V A at 35 °C 50 mm 80 mm
Selection of conductors
in accordance to ampere load and environmental conditions.
U 25 / … C copper conductors for power and control system application.
U 25 / … AE Aluminium conductor and stainless steel conductor surface for power and control system
M6
21
(1) Add last number (1, 2, 3, 4, 5 or 6 m length suffix) in accordance to bars required.
(1) recommendation
23
19 12
ACCESSORIES FOR U 25
Expansion sections Fixpoint Expansion section
factory assembled on 1.5 m long conductor section incl. one X X
rigid joint and will be installed from 150 m of system length on. max. 75 m L max. 75 m
33
+ 320
280 500 –
1
30 Locating clamp
27
Feed terminals
Types UE 25, UE 25 K 4(1), UE 25 AE and UE 25 AE K 4(1)
are adequate to bolted joint splice
ide
27 w Connecting cable Weight kg Cat.-No.
160 Type
max. mm2
UE 25 2 x 16 0,190 170 599
UEG 25 2 x 95 0,560 170 597
21
Isolating sections
30 A 30
max. 200
max. 200 min. 200 max. 200 max. 200
Feed
In order to avoid voltage bridging and for clearing of maintenance, control and live areas use two isolating sections.
Distance A depends on collector type and length of brake path of machinery.
max. 10
M8
26,5
21
27
30
Type M = factory assembled
Type L = Loose Width: 40 mm
M8
8
14,5
27
30
(1) Use flat washers (see page 32) on both sides of brackets with slotted holes.
(2) with stainless steel hardware
25
19 12
ACCESSORIES FOR U 25
KA 25/4
200
Compact hangers, 2 - 4-pole
max. 10
M8
Any number of conductors can be assembled by cutting/
combining the compact hangers.
20
50 25
50 50
25
25 x 30
M8
max. 3
D
d
Ø 28
Transfer guide
This guide serve for transfer
or power interrrupting applications.
26 (1) Attachment hardware to be ordered separately; two flat washers to be used in slotted holes.
(2) with stainless steel hardware
(3) Delivery incl. 2 Attachment hardware SE 8.
COLLECTORS FOR U 25(1) 19 12
75 4 75
approx. 135
85
85
12 12
120
120
approx. 210
150
150
24
24 Ground
Current collectors* For transfer funnel use Double current collectors*For transfer funnel use
KSTU 140/25 or KSTU 175/25 (2) KDSTU 280/25 or KDSTU 350/25 (2)
42
247,5 495
6
spring released height
140
spring released height
140
approx. 220
ca. 220
150
150
24
Ground
(1) The collector of the AE-conductor which are working with only ≤ 10 m/min. travel speed or stand most of the time are only
permitted to work with 50 % of the continuous current.
27
(2) Special collectors for aggressive environments on request.
19 12
COMPONENTS & COLLECTOR BRACKETS FOR U 25
Transfer funnels, 2-pole up to 6-pole
assembled per system layout.
Transfer funnels are necessary for passing switches and turn-
tables.
Conductor spacing 50 mm.
The following collectors have to be used:
For pendant arrangement: KSTU 140/25, KSTU 175/25,
KDSTU 280/25 or KDSTU 350/25.
For lateral arrangement: KSTUR 140/25 on request.
Vmax = 100 m/min.
Connecting conductor bars with transfer guides US 25 K 4 UTI to be
ordered separately.
40 mm wide
Collector brackets for KSTL 15 thru KDSTL 120
5
25
15
18
Prepared for
ground collector
120
12
190
18
11 x 30 slotted hole
600
40
5
65
85
13,5 Ø
120
80
24
24
35
10
600
325
Prepared for
ground collector Prepared for ground collector
28
COLLECTOR COMPONENTS FOR U 25 19 12
Copper-graphite brush
100
75 120 140
10
17
RH
53
RH
RH
KMK 60 KMK 100/25 KMK 140/25
29
19 12
COLLECTOR COMPONENTS FOR U 25
Spares for collectors KSTL 15 thru KDSTL 120
e
➆
30
COLLECTOR COMPONENTS FOR U 25 19 12
➄
➀ ➂
➁ ➃
➅
g
m 12
➈
h 10
11
80 with UEG 25
50
M8 80 with UEG 25
UEG 25
50
M8
max. 10
39.5
max. 9
33.5
40
UEG 25
27
KST 100/25 - KDSTU 350/25 = 150
KSTL 15 - KDSTL 120 = 85
132 VAHLE unipole insulated conductors, 6 m long Phase PH U 25/75 C-6 171 036
3 VAHLE unipole insulated conductors, 5 m long Phase PH U 25/75 C-5 171 035
cut to 4.5
44 VAHLE unipole insulated conductors, 6 m long Ground PE U 25/50 C-6 (1) 171 126
1 VAHLE unipole insulated conductor, 5 m long Ground PE U 25/50 C-5 (1) 171 125
cut to 4.5
9 Expansion sections, 1.5 m long Phase PH UDV 25 C K 4 170 057
3 Expansion sections, 1.5 m long Ground PE UDV 25 C K 4(1) 170 058
176 Bolted joint splices UV 25 170 595
8 Feed terminals UEG 25 170 597
32 Locating clamps USK 25 K 4 170 010
8 End caps UK 25-L 170 013
732 Insulated hangers UA 25 170 761
3 Double collectors Phase PH KDST 280/25 170 542
1 Collector Ground PE KST 140/25 170 539
1 Collector bracket UM 24 175 076
1 Contact greese – 120 017
L
min. 50
200 30
SKO
34
17
M 10
X 50
B
M 10
SKU
200 30
51
34
min. 50
X 50
L
I-Beam flange
Distance X for brackets
width B mm SKO SKU
L = 500 L = 600 L = 700 L = 800 L = 900 L = 500 L = 600 L = 700 L = 800 L = 900
up to 80 170-195 170-295 170-395 170-495 – 120-225 120-325 120-425 120-525 –
over 80 to 120 – 190-275 190-375 190-475 190-575 140-205 140-305 140-405 140-505 140-605
over 120 to 160 – 210-255 210-355 210-455 210-555 160-185 160-285 160-385 160-485 160-585
over 160 to 200 – 230-235 230-335 230-435 230-535 – 180-265 180-365 180-465 180-565
over 200 to 260 – – 260-305 260-405 260-505 – 210-235 210-335 210-435 210-535
SKO SKU
SKO 500 170 094 SKU 500 170 104 500 0.690
SKO 600 170 095 SKU 600 170 105 600 0.780
SKO 700 170 096 SKU 700 170 106 700 0.870
SKO 800 170 097 SKU 800 170 107 800 0.960
SKO 900 170 098 SKU 900 170 108 900 1.050
33
19 12
INSULATED CONDUCTORS U 35
Conductor code:
U = unipole insulated conductor
35 = shroud size
200, 230, 300, 400, 450, 500 = conductor cross
U 35 C sectional area (mm2)
C = copper conductor
AE = Aluminium conductor
contact surface stainless steel
Length:
6.25 m is standard length;
other lengths are available
RH = Radius Horizontal curve Support spacing:
– for straight runs and vertical
inside and outside curves: 2500 mm
– for horizontal curves up to RH = 15 m(1): 1250 mm
41
– for horizontal curves over RH = 15 m: 2500 mm
33
Conductor spacing:
U 35 AE – 90 mm for collectors UST 200/35,
UDST 400/35 and feed UE
23, 5
Curves:
23,5
factory prepared
Heating system:
available
9 See page 4 for shroud properties.
(1) Recommendation
Engineering Data
Cross Leakage Distance of max Continuous Resistance Impedance (3) Ohm/1000 m
Type sectional area covers voltage Amp. capacity on 50 Hz, conductor spacing
copper mm2 mm V A/35 °C Ohm/1000 m
90 mm 130 mm
U 35/200 C 200 85 1000 600 0.094 0.156 0.174
U 35/300 C 300 85 1000 720 0.060 0.138 0.159
U 35/400 C 400 85 1000 860 0.046 0.132 0.154
U 35/500 C 500 85 1000 1250 0.034 0.131 0.152
U 35/230 AE(4) 230 85 1000 500 0.134 0.183 0.199
U 35/450 AE(4) 450 85 1000 800 0.069 0.143 0.163
(2) Add last number (1, 2, 3, 4, 5 or 6 m length suffix) in accordance to bars required, whereby last number 6 relates to the standard 6.25 m sections.
34 (3) Based on 50 Hz.
(4) The collector of the AE-conductor which are working with only ≤ 10 m/min. travel speed or stand most of the time are only
77
Determination of expansion sections
n = L1
L 55 6 3 1 ,5
n = Number of UDV (rounded up)
L1 = system length minus 150 m
L = max. expansion capacity of UDV
12 3 7
43
(see table)
0 °C
+40 a btei 2
0
2500 -5
6 3 1 ,5
Cat.-No. Cat.-No.
Type Weight kg phase ground Type Weight kg phase ground
UDV 35/200-400 C K 4(1) 16.00 175 527 175 528 UDV 35/200-400 C K 4(1) 16.000 175 529 175 530
UDV 35/500 C K 4(1) 17.50 175 540 175 541 UDV 35/500 C K 4(1) 17.500 175 542 175 543
UDV 35 /230-450 AE K 4(1) 7.00 175 517 175 518 UDV 35/230-450 AE K 4(1) 7.000 175 519 175 520
Feed terminals
Connecting Weight
260 e Type cable Cat.-No.
60 wid kg
max. mm2
UE 35/200-400 2 x 150 1,264 175 040
UE 35/500 2 x 150 1,204 175 397
77
Insulated hangers
50
16
40
Insulators
deep
GHH 30-M 12 0.210 175 052 GHH 75-M 12 0.560 175 056
(1) (1)
GHH 30-M 12 K 4 0.210 175 054 GHH 75-M 12 K 4 0.560 175 058
(1)
36 with stainless steel hardware
ACCESSORIES FOR U 35 19 12
End caps
with locking pin 3 x 32
120
Transfer guides
Transfer guides are used for transfer or power-interrupting
applications.
Max. vertical and horizontal offset ± 6 mm . 130
ma x
max. air gap: 20 mm
Type Weight kg Cat.-No.
UTI 35/200 0.060 175 061
UTI 35/300 0.060 175 123
UTI 35/400 0.060 175 124
UTI 35/500 0.060 175 367
UTI 35/230 0.060 175 501
UTI 35/450 0.060 175 502
Photo shows transfer guide with
UTI 35 are transfer buttons (bellmouth shaped conductor ends) conductor section and insulated
50 ds. hanger.
with integrated isolating piece. They are factory assembled to onlo
ocm
UT I 35 w/sot r
layout plans.
In the area of the transfer guide one hanger and the locating
clamps have to be provided
Conductor rails, hangers and locating clamps to be ordered
separately.
Isolating sections
Typ M = factory assembled per layout
Typ L = loose
Consider two extra hangers, max 2 x 400 mm apart
for stabilizing 200 IT/U 35 M
w/o cond.
Conductor rail, hangers and feeds are to be ordered separately
200 A 200
max. 400 max. 400 min. 270 max. 400 max. 400
feed
In order to avoid voltage bridging and for clearing of maintenance, control and live areas use two isolating sections.
Distance A depends on collector type and length of brake path of machinery.
37
19 12
COLLECTORS AND COMPONENTS FOR U 35
Current Collectors Double current collectors
Use current collectors USTR in case of lateral opened Use current collectors UDSTR in case of lateral opened
conductor system conductor system
247 494
72
250 6 250
170
170
78
78
24
24
The collector of the AE-conductor which are working with only ≤ 10 m/min. travel speed or stand most of the time are only
permitted to work with 150 % of the continuous current.
Collector brackets
40 wide
53
40
22
slotted holes 11 x 30
Prepared for
ground collector
226
24
376
35
600
75
100
120
Longer brackets furnished on special order. For 3-pole & ground systems c/w 90 mm cond. spacing.
38
COLLECTORS FOR U 35 (1) 19 12
Current collectors
Use current collectors USTR in case of lateral opened conductor system.
374
72
250
6
325
40
M 16
max. 20
70 for phase 50
120 for ground
47 67
748 72
6
250
325
40
M 16
max. 20
70 for phase 50
120 for ground
47 67
190
(1) The
collector of the AE-conductor which are working with only ≤ 10 m/min. travel speed or stand most of the time are only 39
permitted to work with 50 % of the continuous current.
19 12
COLLECTOR COMPONENTS FOR U 35
Spares for collectors UST 200/35, UST 300/35, UDST 400/35, UDST 600/35, USTR 200/35,
UDSTR 400/35, USTR 300/35 and UDSTR 600/35
c g
d
b h
f k l
m n
j
40
COLLECTOR COMPONENTS FOR U 35 19 12
Spares for collectors UST 200/35, UST 300/35, UDST 400/35, UDST 600/35, USTR 200/35
USTR 300/35, UDSTR 400/35 and UDSTR 600/35
15 Connecting cable RKA 50 mm , 2,7 m long for UST 200/35, UDST 400/35,
2 phase 2.220 175 084
USTR 200/35 and UDSTR 400/35
16 Connecting cable RKA 50 mm2, 2,7 m long for UST 200/35, UDST 400/35, ground 175 085
USTR 200/35 and UDSTR 400/35
17 Connecting cable RKA 95 mm2, 3 m long for UST 300/35, UDST 600/35, phase 3.750 175 149
USTR 300/35 and UDSTR 600/35
18 Connecting cable RKA 95 mm2, 3 m long for UST 300/35, UDST 600/35, ground 175 150
USTR 300/35 and UDSTR 600/35
19 Tension spring ZF 7 for UST 200/35, UDST 400/35, USTR 200/35 and UDSTR 400/35 0.030 160 719
20 Lateral tension spring ZF 6 for USTR 200/35 and UDSTR 400/35 0.023 170 167
21 Tension spring for USTR 300/35 and UDSTR 600/35 0.030 175 558
22 Cable attachment clamp 0.150 175 107
23 Lever compl. for UST 300/35, UDST 600/35, USTR 300/35 and UDSTR 600/35 0.750 175 093
24 Spring box compl. for UST 300/35 and UDST 600/35 2.250 175 094
25 Base plate compl. for UST 300/35 phase 3.470 175 095
26 Base plate compl. for UST 300/35 ground 175 096
27 Base plate compl. for UDST 600/35 phase 3.490 175 097
28 Base plate compl. for UDST 600/35 ground 175 098
29 Terminal bolt M 12 x 25 K4 0.054 175 401
s u
u
21
22
o t
p
q u
23
u
r
24
u
29
u
25 u
27
u
26 u
28
41
19 12
ARRANGEMENT AND EXAMPLE FOR ORDERING U 35
130 with UEG
117 VAHLE unipole insulated conductors, 6.25 m long phase U 35/300 C-6 175 216
3 VAHLE unipole insulated conductors, 4 m long phase U 35/300 C-2 175 214
cut to 3.75 m
39 VAHLE unipole insulated conductors, 6.25 m long ground U 35/200 C-6 (1) 175 266
(1)
1 VAHLE unipole insulated conductor, 4 m long ground U 35/200 C-2 175 264
cut to 3.75 m
3 Expansion sections, 2.5 m long phase UDV 35/200-400 C K4 175 527
1 Expansion sections, 2.5 m long ground UDV 35/200-400 C K4 175 528
156 Bolted joint splices UV 35/200-300 175 012
8 Feed terminals UE 35/200-400 175 040
16 Locating clamps USK 35 K 4 175 039
8 End caps UK 35 L 175 060
404 Insulated hangers UA 35 175 137
6 Double collectors phase UDST 400/35 175 072
1 Double collector ground UDST 400/35 175 073
2 Collector brackets UM 24 175 076
1 Contact grease 120 017
Earthing spider system, 4-pole for insulated conductors – VDE 0105 Part 100 (EN 50110-1)
Serves for earthing and short-circuiting the phase conductors with the ground conductor in the case of maintenance work.
The system consists of terminal clamps for the conductors and copper wire ropes.
Earthing spider system cannot be used together with compact conductor arragement.
L1 L2 L3 PE
43
19 12
QESTIONNAIRE FOR INSULATED CONDUCTOR SYSTEMS
Fa. Date:
Tel: Fax:
Internet: e-mail:
6. Arrangement of conductors:
Conductor rails suspending / Collectors standing
Conductor rails resp. current collectors lateral
Others:
8. Indoor: Outdoor:
13. Number and position of isolating sections (e.g. for maintenance areas):
17. Max. voltage drop from feeder point to current collectors 3% or % of voltage rating
44
QUESTIONNAIRE FOR INSULATED CONDUCTOR SYSTEMS 19 12
Crane 1 Crane 2
Motordata Power
Nominal current Starting current
Power
Nominal current Starting current
kW A cosϕN % ED A cosϕA kW A cosϕN % ED A cosϕA
Hoist motor
Auxiliary hoist
Long travel
Cross travel
Crane 3 Crane 4
Motordata Power
Nominal current Starting current
Power
Nominal current Starting current
kW A cosϕN % ED A cosϕA kW A cosϕN % ED A cosϕA
Hoist motor
Auxiliary hoist
Long travel
Cross travel
Signature:
45
19 12
Notices
46 In accordance with our company’s policy of continued improvement, we reserve the right to amend specifications and details at any time.
19 12
Notices
47
Catalog No. 2 c/E 2006
MANAGEMENTSYSTEM
Catalog No.
Copperhead Conductor Systems 1a
Battery Charging Systems 1b
Insulated Conductor Systems U 10 2a
Insulated Conductor Systems U 20 – U 30 – U 40 2b
Insulated Conductor Systems U 15 – U 25 – U 35 2c
Aluminium Enclosed Conductor Systems LSV – LSVG 3a
Powerail Enclosed Conductor Systems KBSL – KSL – KSLT 4a
Powerail Enclosed Conductor Systems VKS – VKL 4b
Powerail Enclosed Conductor Systems MKLD – MKLF – MKLS 4c
Powerail Enclosed Conductor System VKS 10 4d
Powerail Enclosed Conductor System KBH 4e
Heavy Enclosed Conductor Systems 5
Trolley Wire and Accessories 6
Cable Tenders 7
Cable Carriers for -tracks 8a
Cable Carriers for Flatform Cable on -beams 8 bF
Cable Carriers for Round Cable on -beams 8 bR
Cable Carriers for -tracks 8c
Conductor Cables and Fittings 8L
Spring Operated Cable Reels 9a
VAHLE POWERCOM® – Data Transmission Systems 9c
CPS® – Contactless Power Supply 9d
SMG – Slotted Microwave Guide 9e
WCS – Position Encoding System 9f
Motor Powered Cable Reels 10
0603 · Printed in Germany · 2006-0904 · DS · 1500 · 4/06