Kobold KMT
Kobold KMT
Kobold KMT
Thermal •
KMT
S5
OOMounting and demounting under pressure without
process interruption (with KMT-4)
OO Simple and exact positioning
OO Installation under pressure (with KMT-4)
www.kobold.com
1
Thermal Mass Flow Meter Model KMT
Functions
The flow meter KMT consist of the transmitter and the 1a
mounting valve (only for KMT-1/2/3). The transmitter is
modular and consist of the probe and the signal conditio- 1b
ner. The measurement probe contains the sensor element
and the measurement electronics, in which the data of the
factory calibration is stored. The enclosure with the signal
conditioning is mounted either on the measurement probe
2
(compact) or is remote with a sensor cable up to 10 meter
(33 feet). The mounting valve assembly for KMT-1/2/3 allows
for the easy and reliable installation within the pipeline. The
high measurement accuracy is guaranteed by the accurate,
reproducible positioning of the probe within the mounting
valve. (See design KMT-1/2/3). The ball valve assembly allows for the exact alignment of the
sensing head within seconds during instalment and removal,
with only interrupting the process flow for a short moment.
Non-return protection for secure mounting for KMT-4
The ball valve assembly is suitable for pressures up to 16 bar
The non-return protection combines three functions in one (PN 16) and available for pipe diameters DN 15 (½") to
device: DN 50 (2"). During installation in the pipeline, observe the
required inlet and outlet paths as given in the operating
instructions.
2/09- 2014
2
1
max. 10m
probe cable
Fühlerkabel
flow sensor
Strömungssensor
non-return protection
Rückschlagschutz
mounting grip
Montagegriff
evaluation unit
Auswerteeinheit
Technical Data
Measured flow: Volumetric flow at standard Accuracy (in air at 9 bar
conditions acc. DIN 1343 (abs) (and 23 °C for KMT-4
P0 = 1013.25 mbar; i.e. DN 65 ... DN 300)*: ± 1.5 % of reading
t0 = 0 °C (273.15 K) + 0.8 % of full scale
Temperature coefficient: ± 0.1 % of reading / °C
Measuring range KMT-x1... KMT-x2... Pressure coefficient**: + 0.5 % / bar
Response time t90: < 1 s
DN 15 0.32 ... 63 Nm³/h 0.32 ... 126 Nm³/h
Sample rate: 0.5 s
DN 20 0.57 ... 113 Nm³/h 0.57 ... 226 Nm³/h Measuring range: -20 ... 80 °C
Standardised DN 25 0.90 ... 176 Nm³/h 0.90 ... 352 Nm³/h Accuracy (at 20 °C): ± 0.7 °C
volumetric flow Input: Optional pressure compensation
(air) DN 32 1.45 ... 289 Nm³/h 1.45 ... 578 Nm³/h 4 - 20 mA (2-wire; 14.2 ... 16 VDC)
DN 40 2.26 ... 452 Nm³/h 2.26 ... 904 Nm³/h for pressure sensor
Outputs: Output signal and display
DN 50 3.50 ... 700 Nm³/h 3.50 ... 1400 Nm³/h ranges are freely scalable
Standardised flow Analogue output
(air, nitrogen, CO2, ≤DN 50 0.5 ... 100 Nm/s 0.5 ... 200 Nm/s Voltage: 0 - 10 V max. 1 mA
argon) Current (3-wire): 0 - 20 mA and
4 - 20 mA RL < 500 Ω
Standardised flow
(Helium)
≤DN 50 0.5 ... 100 Nm/s 0.5 ... 120 Nm/s Switching output: Potential-free max. 44 VDC,
500 mA switching capacity
Standardised flow Pulse output: Totaliser,
≤DN 25 0.5 ... 100 Nm/s 0.5 ... 200 Nm/s
(Oxygen) pulse length: 0.02 ... 2 sec.
Digital interface: USB (for configuration)
Flow measuring range in dependence on pipe Electrical connection: Cable entry M 16 x 1,5
diameter (KMT-4) Cable power supply: 18 - 30 VAC/DC
Current consumption: Max. 200 mA (with display)
Inner Measuring range
Pipe Temperature range
Ø KMT-41 KMT-42 Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
inch mm 0.2 ... 100 Nm/s 0.2 ... 200 Nm/s Medium temperature: -20 ... 80 °C (-4 ... 176 °F)
Storage temperature: -20 ... 60 °C (-4 ... 140 °F)
DN 65 2 ½" 70.3 2.8 ...1397 Nm³/h 2.8 ... 2793 Nm³/h Nominal pressure: PN16 (232 PSI)
DN 80 3" 82.5 3.8 ...1923 Nm³/h 3.8 ... 3847 Nm³/h Humidity: No condensation
Medium: Compressed air or non
DN 100 4" 107.1 6.5 ... 3242 Nm³/h 6.5 ... 6483 Nm³/h
corrosive gases
DN 125 5" 131.7 9.8 ... 4902 Nm³/h 9.8 ... 9803 Nm³/h Display: 2 lines LC-Display, backlighting
Electromagnetic
DN 150 6" 159.3 14.3 ...7171 Nm³/h 14.3 ...14 343 Nm³/h
compatibility: EN61326-1 EN61326-2-3
DN 200 8" 206.5 24.1...12 051 Nm³/h 24.1... 24 101 Nm³/h Industrial Environment
Material
DN 250 10" 260.4 38.3 ...19 163 Nm³/h 38.3 ... 38 325 Nm³/h
Housing: Metal (AlSi3Cu)
DN 300 12" 309.7 54.2 ... 27 105 Nm³/h 57.8 ... 57 840 Nm³/h Probe: Stainless steel
Sensor head: Stainless steel / glass
DN 350 14" 339.6 65.2...32 591 Nm3/h 65.2...65 183 Nm3/h Ball valve
DN 400 16" 388.8 85.4...42 719 Nm3/h 85.4...85 438 Nm3/h (KMT-1/2/3): Brass
Non-return protection
DN 500 20" 486 133.5...66 749 Nm3/h 133.5...133 498 Nm3/h (KMT-4): Brass
Housing protection class: IP 65 / Nema 4
DN 600 24" 585 193.4...96 712 Nm3/h 193.4...193 425 Nm3/h
* The accuracy statement includes the uncertainty of the factory calibration
DN 700 28" 682.6 263.4...131 675 Nm3/h 263.4...263 350 Nm3/h with an enhancement factor k = 2 (2-times standard deviation). The
accuracy was culated in accordance with EA-4/02 and with regard to GUM
(Guide to the Expression of Uncertainty in Measurement).
Accuracy (in air at 7bar
**The pressure dependence is + 0.5 % / bar. The KMT is calibrated at 7 bar
(abs) (and 23 °C for (abs). Thus the error at 7 bar = 0 (e. g. additional error at 10 bar = +1.5 %
KMT-1/2/3 i.e. ≤ DN 50)*: ± 1.5 % of reading of reading. This error can be corrected by entering the actual system
+ 0.5 % of full scale pressure (with the configuration software).
2/09- 2014
Use only oil and fat free units for medium oxygen and follow
the corresponding safety regulations.
Connection Diagram
P +15V 7
Pressuresensor
pressure sensor input
input
I
4...20mA
mA_Input 8
V
mA OUT 1-2 9
analogue* or switching output
Signal output 10
OUT 1-1 Signal-Output
Supply
signal output
voltage
OUT 2-1 11
switching or pulse output
OUT 2-2 12
Vcc 13
18...30V AC/DC ≅ 14
Supplyvoltage
Supply
supply voltage
voltage
GND
Cable length
Measuring range /
Model Connection Display Sensor /
Installation length (only KMT-4)
Electronic
14 = 0.32 ... 63 Nm³/h for pipe DN 15 (½")
24 = 0.32 ... 126 Nm³/h for pipe DN 15 (½")
KMT-1...
Sensor compact, 15 = 0.57 ... 113 Nm³/h for pipe DN 20 (¾")
direction of flow 25 = 0.57 ... 226 Nm³/h for pipe DN 20 (¾")
from right to left R = thread-ball
16 = 0.90 ... 176 Nm³/h for pipe DN 25 (1")
KMT-2... valve with
Sensor compact, 26 = 0.90 ... 352 Nm³/h for pipe DN 25 (1") G thread
direction of flow 17 = 1.45 ... 289 Nm³/h for pipe DN 32 (1 ¼") N3) = thread-ball
from left to right valve with
27 = 1.45 ... 578 Nm³/h for pipe DN 32 (1 ¼")
KMT-3... NPT thread
remote probe, 18 = 2.26 ... 452 Nm³/h for pipe DN 40 (1 ½")
according to 28 = 2.26 ... 904 Nm³/h for pipe DN 40 (1 ½")
installation (≤DN50)
19 = 3.50... 700 Nm³/h for pipe DN 50 (2")
29 = 3.50 ... 1400 Nm³/h for pipe DN 50 (2")
(see technical details for flow measuring
range in dependence on pipe diameter)
10 = 2.8 ... 1397 Nm³/h for pipe DN 65 (2 ½") / 165 mm
20 = 2.8 ... 2793 Nm³/h for pipe DN 65 (2 ½") / 165 mm 0 = without
1B = 3.8 ... 1923 Nm³/h for pipe DN 80 (3") / 165 mm 21) = 2 m with
2B = 3.8 ... 3847 Nm³/h for pipe DN 80 (3") / 165 mm plug M 12,
1C = 6.5 ... 3242 Nm³/h for pipe DN 100 (4") / 165 mm 4 pin
0 = without
2C = 6.5 ... 6483 Nm³/h for pipe DN 100 (4") / 165 mm Display 51) = 5 m with
plug M 12,
1D = 9.8 ... 4902 Nm³/h for pipe DN 125 (5") / 315 mm 1 = LCD-Display
4 pin
2D = 9.8 ... 9803 Nm³/h for pipe DN 125 (5") / 315 mm
Z1) = 10 m with
1E = 14.3 ... 7171 Nm³/h for pipe DN 150 (6") / 315 mm plug M 12,
2E = 14.3 ... 14 343 Nm³/h for pipe DN 150 (6") / 315 mm 4 pin
1F = 24.1 ... 12 051 Nm³/h for pipe DN 200 (8") / 315 mm
KMT-4 F = R½" male at
2F = 24.1 ... 24 101 Nm³/h for pipe DN 200 (8") / 315 mm
remote probe immersion
(DN65 ... DN700) 1G = 38.3 ... 19 163 Nm³/h for pipe DN 250 (10") / 315 mm
probe
2G = 38.3 ... 38 325 Nm³/h for pipe DN 250 (10") / 315 mm
1H = 54.2 ... 27 105 Nm³/h for pipe DN 300 (12") / 315 mm
2H = 54.2 ... 54 211 Nm³/h for pipe DN 300 (12") / 315 mm
1J = 65.2 ... 32 591 Nm³/h for pipe DN 350 (14") / 465 mm
2J = 65.2 ... 65 183 Nm³/h for pipe DN 350 (14") / 465 mm
1K = 85.4 ... 42 719 Nm³/h for pipe DN 400 (16") / 465 mm
2K = 85.4 ... 85 438 Nm³/h for pipe DN 400 (16") / 465 mm
1L = 133.5 ... 66 749 Nm³/h for pipe DN 500 (20") / 465 mm
2L = 133.5 ... 133 498 Nm³/h for pipe DN 500 (20") / 465 mm
1M = 193.4 ... 96 712 Nm³/h for pipe DN 600 (24") / 465 mm
2M = 193.4 ... 193 425 Nm³/h for pipe DN 600 (24") / 465 mm
1N = 263.4 ... 131 675 Nm³/h for pipe DN 700 (28") / 465 mm
2N = 263.4 ... 263 350 Nm³/h for pipe DN 700 (28") / 465 mm
Order Details (continued) next page
2/09- 2014
Measuring sec-
Measuring
Model Design tion Mounting
range
pipe diameter
4 = DN 15
5 = DN 20
6 = DN 25
K = for ball valve
7 = DN 32
8 = DN 40
9 = DN 50
0 = DN 65
B = DN 80
1 = sensor compact (direction of flow right to left)
C = DN 100
2 = sensor compact (direction of flow left to right) 1 = low
ERS-KMT-S D = DN 125
3 = remote probe (≤ DN 50) 2 = high
E = DN 150
4 = remote probe (DN 65 ... DN 700)
F = DN 200
F = R½" male at
G = DN 250 immersion
probe
H = DN 300
J = DN 350
K = DN 400
L = DN 500
M = DN 600
N = DN 700
2/09 - 2014
Model
25
11
Ø 18,63
G1/2
G3/4
70
interruption
G3/4“
15
64,5
70
ERS-KMT-KP
G3/4“
G1/2“
16
14
SW24
Ø 15
KMT-1...
KMT-2...
183
173
115
45
60
38
20
USB-Interface
56
Ø 40
120
285/435/585
SW 36
R½" thread
marking flow
direction
or 315 (DN 125 ... DN 300)
or 465 (DN 350 ... DN 700)
Ø 13
(DN 65 ... 100)
Ø 14
insertion depth = x + OD
2
12
OD ... outside diameter
x
M12 x 1 connector
for probe cable
Ø
40
0,5 * OD
OD
51,5
54
G3/4“
G1/2“
G1/2“
G3/4“
Ø15
Ø15
54,5
64,5 Material: brass
lateral fitting for
mounting of
pressure or dew
point sensor 64,5 material: brass
25
ball valve ERS-KMT-KH
rubber sealing NBR 70 Shore
G3/4“
∼95
11
22
threaded nipple
185