Firmware 7.6.0.

0 resolves this issue:


IT10470 - Noisy/high speed fan. Other Storages affected: V5000, V3700, V3500
Temporarily fixed using "chenclosurecanister -reset -canister "
I just tried it myself:
Connect via ssh to the storage.
 default logon user: superuser
 default password: passw0rd
Make the canister above the dumb psu fan to flash:
chenclosurecanister -identify yes -canister 2 1 (canister 2, enclosure 1 for example)
If the canister is the right one:
chenclosurecanister -reset -canister 2 1
The fan will go 120% for 30 seconds and then will drop to normal levels.
Reference:
Release Notes Firmware
7.6.0.3 http://public.dhe.ibm.com/storage/san/sanvc/release_notes/760_releasenotes.html
Chenclosurecanister command reference http://www-
01.ibm.com/support/knowledgecenter/ST5Q4U/com.ibm.storwize.v7000.unified.142.doc/manpages/
chenclosurecanister.html

Tham khảo: http://public.dhe.ibm.com/storage/san/sanvc/release_notes/760_releasenotes.html

IT10470 V5000, Suggested Noisy/high speed fan (hide details) 7.6.0.0


V3700,
V3500 Symptom None

Environment V3k & V5k systems

Trigger None

Temporarily fixed using "chenclosurecanister


-reset -canister" CLI command

E.g. To reset canister 1 of enclosure 3


enter chenclosurecanister -reset -canister 1 3
Workaround Note: The command should only be used on
one node canister at a time with a pause, of
30 minutes, between reset of node canisters
in the same control enclosure. Customers
running v7.5 code levels should be aware of
HU00996

Chú ý khi upgrade lên version trên:


Hello, I'm getting this error when i need to upgrade to latest release 7.6.0 on V3700
each node is 4GB Ram ,
******************** Error found ********************
The system has at least one node canister with only 4GB of RAM installed
This will prevent an upgrade to 7.6.0.0 from succeeding.
Please see the following web page for more information:
http://www.ibm.com/support/docview.wss?rs=591&uid=ssg1S1005405
Results of running svcupgradetest:
==================================
The tool has found 1 errors and 0 warnings.
One issue will prevent the system being
updated to 7.6.0.0 until it has been resolved

Như vậy, cần kiểm tra, collect support log và phân tích

- version firmware
- dung lượng RAM của canister

Nếu RAM dung lượng bé hơn 4GB thì phải nâng lên 8GB mới nâng cấp được firmware và mới fix được lỗi
này.