PSF096TFIS:Layout 1 07/01/2011 09:53 Page 1

DATASHEET

T1000
Intelligent Marine Control Panels

Features
Developed for Vessels with less than 300 detectors
Approved by all major Marine Authorities
Customer friendly, miltu language information on LCD
display
Comprehensive fault diagnostics
Executive actions for Fire Doors, Local Extinguishant
Release, Fans/Blowers
Interface to other shipboard Control/Graphic systems
One man installation
8 and 16 Zone panels
Wide range of Minerva Marine approved detectors
4 Monitored sounder outputs up to 4A
4 Monitored relay outputs
3 Programmable auxiliary inputs
3 Levels of alarm discriminations per zone
Programmable cause and effect

T1000 Intelligent Marine Control Panels


The range of T1000 panels are state-of-the-art intelligent fire
panels, which provide many of the features normally only
found on more expensive analogue addressable panels.

The panels are supplied in 8 and 16 zone versions. Each


detection zone can support up to 32 conventional detectors or
24 if detector removal monitoring is used. Alternatively an
unlimited number of manual callpoints can be used on each
zone.
PSF096TFIS:Layout 1 07/01/2011 09:53 Page 2

T1000 Intelligent Marine Control Panels


Overview Of Operation Sounder and Auxiliary Outputs
The panel provides detection zone monitoring and sounder output The panels each have four separately fused and monitored alarm
monitoring. Detection zones are monitored for detector removal as output circuits, suitable for sounder circuits installed as continuous
well as open and short circuit fault conditions. The panel also pairs. Each circuit is capable of driving 1A with a total sounder
provides common fault and four programmable changeover relay current of 4A.
outputs rated 1A @ 24V dc.
Four additional non-monitored relay outputs are provided on each
The common fault relay is normally energised and de-energises to panel to provide auxiliary command signals to equipment such as
signal any zone fault, processor fault, mains failure, battery fault, signalling devices. A common fault relay output is also provided.
earth fault and supervised output fault. The four programmable
relays can be set to be normally de-energised or energised to signal An optional I/O expansion board can be fitted to the panel. This
any zone fire, evacuation alarm, fault, technical alarm or disable board has 4 ports. Two of these ports are used for other special
condition. application variants of the panel. The two remaining ports can
support a 16 digital output and a 16 relay output card. These can be
Detection Options used to drive LED mimics or provide zonal outputs. The outputs can
MR601M Optical An excellent all-round Detector be programmed to respond to one or more alarm type on each
suited to all applications. respective zone.
MF601M ION Chamber Ion Chamber Detectors suitable for
use where there is invisible smoke The panel also has two 24V DC auxiliary supply outputs which are
so are used for early detection of monitored for fuse failure and both rated at 1A.
wood or other carbon based files.
MD601 Rate of Rise Used where Smoke Detectors Ease of Installation
cannot be Heat used e.g. Galleys, The panels are designed for one man installation. 20mm cable
Laundries, Drying Rooms gland entries are provided from the top, bottom and rear and a
MS302Ex Flame Used where there is a risk of large removable and reversible hinged lid provides easy access during
flaming fires e.g. Machinery Spaces. installation.
MU601M Carbon The best Detector for early warning
Monoxide without false alarms. The panels have sufficient space internally for two 12V 12Ah
Used in life hazard applications batteries which can provide up to 72 hours standby power
e.g.Cabins, Public Spaces. depending upon the loading of the panel.

The T1000 panels’ default configuration is set for use with the User Interface
companies own highly acclaimed internationally approved Lo-pro The user interface is provided through a combination of LEDs and a
detector range.. 2 x 40 character LCD display. The LEDs provide clear indication that
a fire, fault, isolate or technical alarm condition is present.
The T1000 panel is also fully compatible with the companies unique
MU601 Carbon Monoxide fire detector. The display also shows the first and last zone in Alarm and Fault.

For hazardous applications the panels have been tested with the The user interface provides two rows of user selectable buttons. The
companies intrinsically safe BASEEFA certified System 601 which first row is used to deal with emergency and alarm situations whilst
includes the M300Ex intrinsically safe range of smoke, temperature the second row is used for information enquiries. The first row
and flame detectors (See Note 1). includes the ability to view alarms, silence, accept, reset and
evacuate. The second row provides the ability to view historical
Plant Alarm Monitoring alarms, fault conditions, technical alarms and disable conditions.
Zones on the Panel can also be programmed to monitor Machinery
Spaces Fans/Blowers, Fire Doors and Engine Room Fire Dampers. The LCD display provides a full customer definable text display of the
alarm or fault condition whilst also displaying zones in alarm, fault or
Auxiliary Inputs isolate status. The display also indicates the outputs that have been
Three additional programmable inputs on the panel can be used for activated.
Muster signals, initiation of sounder circuits for indicating class
change in educational establishments and providing Remote Reset
or Remote Accept signals.
PSF096TFIS:Layout 1 07/01/2011 09:53 Page 3

T1000 Intelligent Marine Control Panels


Programmable Cause and Effect One Man Walk Test
The LCD display and keypad allow site configuring of the cause and The user interface also allows a One Man Walk Test to be carried out
effect between inputs and outputs and adjusting of other settings. during weekly visits. This facility leaves the panel fully functional on all
This includes the following functions: but the zone being walk tested. This function allows each zone to be
walk tested, one at a time. Once in Walk Test mode, an alarm condi-
Selecting zones to detect manual callpoint alarms and/or fire tion on the zone is indicated by the sounders for one second.
alarms and/or technical alarms
Selecting which zonal alarm thresholds will trigger which Manned and Unmanned Mode
programmable sounder and auxiliary outputs as well as the A user key is provided to toggle the system between manned and
output pulse timings and fail safe status. unmanned mode. This could be used to change the response to
Determining which types of alarm will trigger zonal outputs alarm conditions when the machinery space is unmanned.
or LED mimic outputs
Selecting the functionality of the auxiliary inputs and outputs
and configuration of expansion I/O
Language Variants
Configuration of the period a mains failure situation must The panels are available with a variety of language overlays for the
exceed before a mains fault is initiated. front panel. Each variant supports 6 languages on the LCD display
Configuration of the battery test facility and zone detector which can be swapped during operation via a key on the user
removal monitoring interface. The standard version offers English, Spanish, Italian, French,
Configuration of zonal alarm delay timers Portuguese and Dutch.

Zone Isolate & Sounder Disable Fireman’s Interface


The T1000 allows zones and sounder circuits to be individually The panel has the ability for a fireman's panel to be integrated into
isolated. Isolated zones and disabled outputs are indicated on the the main panels’ front fascia. Standard fireman’s panels are available
LCD display. for Norway, Sweden, Finland and Denmark.

Optional Printer
An optional printer can be fitted within the NT1000 panel to provide
an on-line printout of events as they occur. Alternatively the printer
can be commanded to print out a selected list from the alarm and
T1000 FIRE PANEL event history.
PSF096TFIS:Layout 1 07/01/2011 09:53 Page 4

SPECIFICATIONS

Technical Information Outputs


Mechanical Sounder Outputs: Monitored, separately fused, 1A rating
Dimensions (mm): 430 W x 320 H x 150 D Relay Outputs: Fault + 4 programmable
Enclosure Material: Cast Aluminium Front Cover outputs - SPDT 1A@24V dc
Steel Back Box
20mm Cable Entries: 26 Top and 2 Bottom , OR Total Power Supply Loading
2 Top and 26 Bottom Output Current: 4A Maximum
11 x rear (Mains entry)
Total Supply Failure (optional third power supply)
Electrical Supply Voltage: 9V dc battery (PP3)
Mains Supply
Supply Voltage: 198 to 264V ac
Supply Frequency: 45 to 66Hz
Supply Current: Quiescent: 50mA
Active: 1A
Active Mains Fuse 3A 250V ac

Inputs
Detector Circuit:
2.2mA max with resistor 6k8 EoL (50R max line resistance)
Alarm Level 1 (e.g. Alarm) - 550 to 1kOhms
Alarm Level 2 (e.g. evacuate) - 85 to 270 Ohms (Max. 32 x M300
or M600 detectors per zone or 24 with detector monitoring enabled
Note 1)
Aux Inputs: 24V dc line voltage
Note 1 - Refer to document number 26A for design details on sys-
tem 601 BASEEFA certified Intrinsically Safe applications.

Mounting Arrangement

For further information on how we can help you, please visit our website at www.tycofis.com or e-mail us on [email protected].
The right is reserved to modify or withdraw any product or service without notice. PSF096TFIS Issue 2 November 2006 © 2006