Diesel Generator Set PJPS-1000 WP: 50 Hz/Prime Power/Fuel Consumption Optimized/Water Cooled/Turbo/Charge Air Cooling
Diesel Generator Set PJPS-1000 WP: 50 Hz/Prime Power/Fuel Consumption Optimized/Water Cooled/Turbo/Charge Air Cooling
Diesel Generator Set PJPS-1000 WP: 50 Hz/Prime Power/Fuel Consumption Optimized/Water Cooled/Turbo/Charge Air Cooling
PJPS-1000 WP
50 Hz/Prime Power/Fuel Consumption Optimized/Water
Cooled/Turbo/Charge Air Cooling
PRODUCT HIGHLIGHTS
// Power Rating
System prime ratings: 1000 kVA
System standby rating up to 110% prime ratings with
maximum of 1 hour within 12 hours
// Voltage Regulation
Maintains voltage output to within +/-0.5%
At any factor between 0.8 lagging and unity
At any variation from no load to full load
At any variations from cold to hot temperature
2 / // / PJPS-1000 WP / 50 Hz / 380V – 1000kVA
APPLICATION DATA
// Engine // Cooling
Radiator System
Manufacturer Perkins Fan power for mech. radiator (40°C): kWm 38
Model 4008TAG2A
Type 4-cycle // FuelConsumption
Arrangement 12V At 100% of power rating: l/hr 215
Displacement: l 30.561 At 75% of power rating: l/hr 162
Bore: mm 160 At 50% of power rating: l/hr 111
Stroke: mm 190
// System Ratings (kW/kVA)
Rated speed: rpm 1500
Engine governor Electronic Alternator Prime Rating
Voltage
Max power: kWm 947 Model kVA kWe
Air cleaner Dry Stamford
380 1000 800
HCI634J
// Fuel
System * cos phi = 0,8
Type Direct Injection
Fuel tank capacity : l REQ
// LiquidCapacity (Lubrication)
Total oil system capacity: l 153
// Control Panel
■ Main control panel Automatic mains failure operation Mains parallel operation of
■ Digital metering with ATS multiple gensets
■ Engine parameters Island operation Expansion modules
■ Generator protection functions Automatic mains failure operation Remote annunciator
incl. control of generator and Generator winding temperature
■ Engine protection
mains breaker monitoring
■ Parametrization software Island parallel operation of Generator bearing temperature
■ Multilingual capability multiple gensets monitoring
■ Multiple programmable contact Automatic mains failure operation Differential protection relay
inputs with short mains parallel overlap Modbus RTU-TCP gateway
■ Multiple contact outputs synchronization SCADA system remote controller
■ Event recording Mains parallel operation of a
■ Daily tank control single genset
H H
L W W L
Drawing above for illustration purposes only, based on standard open power engine-generator set. Lengths may vary with other variances.
SOUND DATA
// Consult PT. Conductorjasa Suryapersada energy consultant for sound data
EMISSIONS DATA
// Consult PT. Conductorjasa Suryapersada energy consultant for emission data
PT CONDUCTORJASA SURYAPERSADA
A JERBINDO Systems Brand
www.conductorjasa.co.id