Puritan- Bennett 760 Ventilator Specification

Ventilator Type: Positive Pressure


Invasive
Non Invansive
Conventional

Ventilator Class: Intensive Care Unit (ICU)


Transport
Sub acute
CPAP

Patient Range: Pediatric


Adult
CHARACTERISTICS:

Modes - Invasive: Controlled modes: Assist Control (Volume control, Pressure control)
SIMV modes: Volume control + Pressure support,
Pressure control + Pressure support
SPONT modes: Pressure support, Pressure support + PEEP

Special mode of operation: Apnea Ventilation, Manual breath, Speaking Valve, 100 % O2 suction,
Insp. pause & Exp. pause

SPECIFICATIONS:

Operating range of control:


(VCV and PCV ) Settings: Respiratory rate: 1 to 70 breaths/min
Tidal Volume: 40 to 2000 ml. Compliance - compensated (BTPS)
Peak Flow: 3 to 150 L/min (Controlled breaths)
300 L/min (Spontaneous breath)
Plateau: 0.0 to 2.0 seconds
Flow Pattern: Square & Decelerating ramp
Inspiratory pressure: 5 to 80 cmH2O
Inspiratory Time: 0.2 to 8.0 seconds
I/E ratio: 1:99 to 4:1
Rise time factor: 5 to 100

Spontaneous Settings: Support pressure: 0 to 70 cmH2O


Rise time factor: 5 to 100
Exhalation sensitivity: 1 to 80 %

Common Settings: PEEP / CPAP: 0 to 35cmH2O


Trigger sensitivity: 1 to 20 L/min
% O2 21% to 100%

FEEL FREE TO CONTACT US FOR MORE DETAILS

ivya Meditech Systems 49, Mahavirnagar Society, B/S R.J.Tibrewal Commerce College,Vastrapur, Ahmedabad-380015.GUJARAT.
A bunch of Medi-tech Solutions Tel: +91- 98251 16441,+91- 90990 24862; Email :[email protected]
Dealing in Medical Equipments Web: www.divyameditech.com
Page: 1 of 2
Puritan-bennett 760 Ventilator Specification

Alarm Control: High Rate: 3 to 100 breaths/min


Low Insp. pressure: 3 to 60cmH2O
High Pressure: 10 to 90cmH2O
Low minute volume: 0 to 50 L
High Tidal Volume: 20 to 6000 ml
Low Tidal Volume: 0 to 2000 ml

Patient Parameters
Monitoring and Display: Pressure Bar Graph, Breath (Mand., asst., Spont.), Exp .Volume Bar Graph,
Peak Pressure, Respiratory rate, Mean pressure, Inspiratory time,
PEEP/CPAP, I:E Ratio, Delivered Volume, Exhaled Volume,
Spontaneous minute volume, Total minute volume,

Ventilator Settings: Respiratory Rate, Apnea parameter, Inspiratory pressure,


Trigger sensitivity (L/min), Tidal volume, % O2, I/E ratio or Ti, 100% O2,
Peak flow, Manual Insp, Rise time factor, Insp.pause,
Expiratory pause, Exhaled sensitivity, Plateu, Alarm reset, Support pressure,
2 min off alarm

Alarm: Alarms are designed to ISO and European standards and classified
as high/medium priority

Ventilator Status Indicator: Alarm, Caution, Normal, Ventilator In operate, Disconnect, Safety Valve Open,
On AC/Battery charging, On Internal Battery, Internal battery level,
On External battery

Special Features: 2.5 hrs of battery back up under nominal condition.


In Built compressor (Friction less piston) Technology.
O2 Pressure (40 to 90 psi).
Ventilator can operate with out pressurized O2 and Air.
Safety Valve operation.
Less maintenance cost.
Ventilator can measure: C, R, Total PEEP, Int. PEEP, END Exp. flow, END flow
Weight: 30 kg
O2 cell life: 1 yr. or depend on the operating environment.

FEEL FREE TO CONTACT US FOR MORE DETAILS

49, Mahavirnagar Society, B/S R.J.Tibrewal Commerce College,Vastrapur, Ahmedabad-380015.GUJARAT.


ivya Meditech Systems Tel: +91- 98251 16441,+91-90990 24862; Email: [email protected]
A bunch of Medi-tech Solutions

Dealing in Medical Equipments


Web: www.divyameditech.com
Page: 2 of 2

You might also like