The Siemens Servo Ventilator 900C is an advanced ventilator that can be used for infants through adults in intensive care, anesthesia, and patient transportation. It has 8 ventilation modes and monitors airway pressure, expired minute volume, and other values. For quality pre-owned units with warranty, contact Zigma Medical Technologies.
The Siemens Servo Ventilator 900C is an advanced ventilator that can be used for infants through adults in intensive care, anesthesia, and patient transportation. It has 8 ventilation modes and monitors airway pressure, expired minute volume, and other values. For quality pre-owned units with warranty, contact Zigma Medical Technologies.
The Siemens Servo Ventilator 900C is an advanced ventilator that can be used for infants through adults in intensive care, anesthesia, and patient transportation. It has 8 ventilation modes and monitors airway pressure, expired minute volume, and other values. For quality pre-owned units with warranty, contact Zigma Medical Technologies.
The Siemens Servo Ventilator 900C is an advanced ventilator that can be used for infants through adults in intensive care, anesthesia, and patient transportation. It has 8 ventilation modes and monitors airway pressure, expired minute volume, and other values. For quality pre-owned units with warranty, contact Zigma Medical Technologies.
The unique ventilator designed for intensive care, anesthesia
and patient transportation, for infants through adults
For Quality Pre-owned units
with warranty Contact:
110/115, A Block, Shivalaya Buildings, Commander-in-Chief Road, Egmore, Chennai - 600 105 Ph: +91-44-52148380 Fax: +91-44-28270306 Email: [email protected]
Zigma Medical Technologies acknowledges all registered trademarks of manufactures’ listed.
The technical data given in this publication are for general information and are subject to change without notice. General information With the Servo Ventilator 900C, the patient can The Servo Ventilator 900C is an advanced be treated according to eight different ventilation electronic ventilator capable of treating the modes. neonate as well as the adult patient. The Servo Ventilator 900C can be used in intensive care, anesthesia and transportation Technical Specifications Digital presentation General Respiratory rate Range 5-120 breaths/min Dimensions W 50 X D 23 X H 23 cm (basic O2 concentration In % by volume: range 20- dimensions) 100% Weight Approximately 19 Kg (42 lb) Inspired tidal volume Range 0-1999 ml Insp. flow Constant or accelerating. Expired tidal volume Range 0-1999 ml pattern Decelerating in Pressure Expired minute ADULTS range 0-40 l/min Controlled Ventilation Volume INFANTS range 0-40 l/min Compressible 0.075 I (internal) Peak pressure Range 0-120 cm H2 O Pause pressure Range 0-120 cm H2 O volume Ventilation controls, control ranges Mean airway pressure Range 0-120 cm H2 O Working pressure Up to 120 cm H2 O Alarms and indicators Modes VOL.CONTR (Volume Controlled) Push button Audible signals, muted VOL. CONTR + SIGH (Volume for 2 minutes (max) Controlled with sigh) Alarms Gas supply failure PRESS CONTR.(Pressurecontrolled) Apnea PRESS.SUPPORT (Pressure Support) Expired minute volume SIMV (Synchronized Intermittent O2 Concentration Mandatory Ventilation) Upper Pressure limit SIMV +PRESS. SUPORT Mains power failure CPAP (Continuous Positive Airway Pressure) Indicators Set minute volume alarm MAN (Manual ventilation: auxillary Set O2 alarm equipment necessary) Pressure support CPAP Preset inspiratory 0.5-40 l/in. With sufficient working MAN. minute volume pressure SIMV HIGH/LOW RATE Respiratory rate 5-120 breaths/min Expired minute volume Inspiratory time 20, 25, 33, 50, 67 or 80 % of the infants respiratory cycle Patient trig Pause time 0, 5, 10, 20 or 30 % of the respiratory Gas and power supply cycle Gas Must fulfill specifications PEEP 0-50 cm H2 O for medical gases Upper Pressure 15-120 cm H2 O Gas consumption Approximately equal to limit inspiratory minute Trig Sensitivity -20-0 cm H2 O (below PEEP) volume or equal to SIMV-rate HIGH RATE (4-40 SIMV breaths/min) flowmeter setting LOW RATE (0.4-40SIMV breaths/min) Gas supply via high From Central gas supply, Sigh Doubled tidal volume possible every pressure inlet compressor or gas 100 breaths cylinder Special functions Inspiratory pause hold Electronic gas supply 2.5-5 bar (250-500 kPa; unit, inlet pressure 35-70 psi) Expiratory pause hold Gas Change Other gas supply 2.5-7 bar (250-700 kPa; Monitoring: unit, inlet pressure 35-100 psi) Gas supply via low Via flowmeter(s) Analog presentation Airway pressure Range -20-120 cm H2 O pressure inlet Power Supply 220-240 V 50 or 60 Hz Expired minute ADULTS range 0-40 l/min INFANTS range 0-40 l/min Power Consumption Approximately 40 W