141 APPEL Areva Pump Test Loop

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Center - Focus on Technology

APPEL
AREVA Pump Test Loop

Qualication of pumps according to ISO 9906


and at accident operation conditions fast thermal transients, particle loaded water
The challenge
Qualication of pumps at accident conditions like
fast thermal transients or during operation with
particle loaded water following a LOCA in addition
to standard conditions like described in ISO 9906
The solution
Set up of a test facility which is able to perform
standard pump performance tests according
ISO 9906 but special tests as well without changing
test loop components. For the operation of pumps
in nuclear power plants a qualication at standard
conditions like dened in ISO 9906 is often not
sucient. Special operating boundary conditions
like thermal transients or pump operation with
particle loaded water have to be taken into account

as well as endurance tests. The APPEL facility


shows maximum exibility regarding the kind of
qualication requested.
Measurements by default are:
Flow rate
System pressure
Pump discharge head
Vibration behavior of pump and motor
Fluid temperature
Temperature of pump and motor components
Motor power
Pump rotation frequency

Vessel circuit
Main circuit
Cooling circuit

APPEL Pump Test Facility

AREVA Pump Test Loop APPEL


During the pump operation at fast thermal transients the pump can be thermally shocked with a
temperature dierence of 165 K in less than 30 s,
the shocks can be applied cold/hot or even hot/cold.
Pump endurance tests even at elevated temperatures can be performed for several hundred hours
combined with frequent switch on/switch o
operations of the pump.
The pump operation with particle loaded water can
be performed during long term, the debris mixture
can be prepared and supplied by AREVA.
APPEL Applications
Qualication test series have been performed for:
Standard Chemical Pumps (EN 9906)
Single stage / multi stage Vertical Pumps
(EN 9906)
LHSI pumps for EPR (EN 9906, Thermal
transients and debris tests)
EVU pumps for EPR (EN 9906, Thermal
transients and debris tests)
LHSI pumps for other NPPs (EN 9906,
Thermal transients and debris tests)

APPEL Test Facility Specication:


Test Facility material:
Stainless steel
Max. Pressure:
40 bar pump suction side
Max. Pressure:
100 bar pump discharge side
Max. System temperature:
200 C
Max. Flowrate:
1000 m/h
Max. Drive power:
450 kW

Test Facility specications

One Pump Test Facility to


satisfy all your needs

Your benets at a glance


Pump test facility with maximum exibility combining standard EN 9906 application
and special tests
Integration and access to AREVAs thermal-hydraulic platform
Accredited test and inspection body
Open to external costumers

AREVA GmbH
Your contact: [email protected]
Editor and Copyright 2012: AREVA GmbH Paul-Gossen-Strae 100 91052 Erlangen, Germany. It is forbidden to reproduce the present publication in its entirety or partially in
whatever form without prior written consent. Legal action may be taken against any infringer and/or any person breaching the aforementioned conditions.
Subject to change and error without notice. Illustrations may dier from the original. The statements and information contained in this brochure are for advertising purpose only and
do not constitute an oer of contract. They shall neither be construed as a guarantee of quality or durability, nor as warranties of merchantability or tness for a particular purpose.
These statements, even if they are future-oriented, are based on information that was available to us at the date of publication. Type, quantity and characteristics of goods and services
are subject to formal individual formal contracts.