This document describes how to install the Kongsberg Maritime

FleetMaster Technical Log.

Kongsberg Maritime

Rev.
A
B
C
D
E
F
G

Rev. A
Rev. B
Rev. C
Rev. D
Rev. E
Rev. F
Rev.G

Written by
Date
07.06.2006
02.02.2007
05.03.2007
05.06.2007
15.02.2008
30.02.2009
06.09.2010

FleetMaster

Checked by
Date

Sign.
AJE
ThLe
ThLe
ThLe
ThLe
ThLe
ThLe

Sign.

First issue
General update
Added Network testing and patching info
Added info on replacing old FM installations
CB-0533 Added info on InstallChecker
Included limitations for Windows NT
Added info for Windows 7

Approved by
Date
Sign.

- Release 4.5.1
- Release 4.6.0
- Release 4.6.1
- Release 4.6.2
- Release 4.6.3
- Release 4.6.4
- Release 4.6.5

The information contained in this document is subject to change without prior notice.
Kongsberg Maritime AS shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of this
document.
2007 Kongsberg Maritime AS. All rights reserved. No part of this work covered by the
copyright hereon may be reproduced or otherwise copied without prior permission from
Kongsberg Maritime AS.

CN-0524 / G 08.09.2010

!
"
!$% "$ "$

Kongsberg Maritime

1.

FleetMaster

GENERAL ............................................................................................................................................ 5
1.1 REQUIREMENTS ................................................................................................................................. 5
1.2 WHAT IS NEW? ................................................................................................................................... 5
1.3 MISCELLANEOUS ............................................................................................................................... 5
1.4 ABBREVIATIONS ................................................................................................................................ 5
1.5 DIFFERENT TYPES OF INSTALLATION.................................................................................................. 5
1.5.1
DC C20 Gateway installation .................................................................................................. 6
1.5.2
DC C20 Client installation ...................................................................................................... 6
1.5.3
DC C20 ShipViewer installation ............................................................................................. 6
2.
INSTALLATION ................................................................................................................................... 7
2.1 INSTALLING ON WINDOWS 7 .............................................................................................................. 8
2.1.1
RUN THE SETUP AS AN ADMINISTRATOR ........................................................................................ 8

2.2

AUTOMATIC SETUP ........................................................................................................................ 9

3.

NETWORK SETUP .......................................................................................................................... 11


3.1 CHOICE OF NETWORK....................................................................................................................... 11
3.2 GATEWAY SETUP ............................................................................................................................. 11
3.2.1
Configure network adapter for the process network ............................................................. 11
3.2.2
Configure network adapter for NetworkActiv application .................................................... 11
3.2.3
Configure network adapter for the administrative network ................................................... 12
3.2.4
Testing the network (DC2000)............................................................................................... 12
3.2.5
Testing the network (DC-C20)............................................................................................... 12
3.3 CLIENT SETUP .................................................................................................................................. 13
3.3.1
Ship Viewer Only. .................................................................................................................. 13
3.3.2
Network adapter for the administrative network ................................................................... 13
3.3.3
Testing the network (DC2000)............................................................................................... 14
3.3.4
Testing the network (DC-C20)............................................................................................... 14

4.

WINDOWS XP/7 AND DC2000 ....................................................................................................... 16

5.

ADDITIONAL SETUP ...................................................................................................................... 17


5.1 GATEWAY ........................................................................................................................................ 17
5.1.1
Network Active ....................................................................................................................... 17
5.1.2
Sharing the FleetMaster folder .............................................................................................. 18
5.2 DATACHIEF C20 VERSION 9 AND UP ................................................................................................ 22
5.2.1
Microsoft Installer 3.0 ........................................................................................................... 22
5.2.2
.NET framework .................................................................................................................... 22
5.2.3
Visual C++ 5.0 runtime support ........................................................................................... 23

6.

FLEETMASTER SETUP ................................................................................................................. 24


6.1 REPLACING OLDER VERSIONS .......................................................................................................... 24
6.1.1
REPLACING VERSIONS UP TO 4.6.2 .............................................................................................. 24
6.1.2
REPLACING VERSIONS 4.6.3 AND UP FOR DC-C20....................................................................... 25
6.2 INSTALLATION OF FLEETMASTER APPLICATIONS............................................................................. 25
6.3 INSTALL PATCHES ............................................................................................................................ 26

7.

AFTER INSTALLATION ................................................................................................................ 27


7.1 GATEWAY ........................................................................................................................................ 27
7.1.1
Configure network adapter for the administrative network ................................................... 27
7.1.2
Calculate broadcast address ................................................................................................. 27
7.1.3
Configure NetworkActiv application ..................................................................................... 27

CN-0524 / G 08.09.2010

Kongsberg Maritime

FleetMaster

7.2 CLIENT ............................................................................................................................................. 29


7.2.1
Configure network adapter for the administrative network ................................................... 29
7.3 DATACHIEF VERSION 9. ................................................................................................................... 30
7.4 SHIPVIEWER .................................................................................................................................... 31
7.4.1
COPY THE FLTMIMIC.DLL ............................................................................................................ 31
7.4.2
Changing Ship Viewer mimic files ......................................................................................... 32
7.5 RESTART .......................................................................................................................................... 32
8.

FLEETMASTER START UP ........................................................................................................... 33


8.1 COPY DATABASE .............................................................................................................................. 35
8.1.1
WINDOWS NT ............................................................................................................................. 36
8.2 VERIFYING THE START-UP ................................................................................................................ 36

CN-0524 / G 08.09.2010

Kongsberg Maritime

!"!

FleetMaster

This manual contains information on how to install the latest FleetMaster


software on various Windows platforms and for various DataChief (K-Chief)
versions.
If you need to install or fix problems related to older versions of FleetMaster or
ShipViewer, please read CN-0538-X Technical Log Troubleshooting .doc (X
denotes the latest available revision of the document).

Computer: Processor 733 MHz. 128 MB MAM. 100MB hard disk free space.
Operating System: In order to run the FleetMaster Ship Gateway, you need a
computer with Windows NT/SP6, Windows 2000/SP3, Windows XP or Win7.
In order to install FleetMaster for DataChief version 9.0 and higher, you need
Windows 2000/SP3, XP or Win7.
InstallChecker: In order to run installChecker you need Windows 2000, XP or
Win7.

&

'

Please see the release notes (Release.PDF) installed with the product and also
stored on the release CD.

When installing FleetMaster Technical log (ShipViewer), you should have the
current project fltmimic.dll file (FleetMaster mimic file). The FleetMaster does
not depend on this file and will be fully functional without it, but project specific
mimic pictures are preferred.

ROS: Remote Operator Station (Data Chief C20 operator control station)
FPG: FleetMaster Process Gateway

There are several ways to install the FleetMaster software. Please refer to the
project specification for details on your type of installation.

CN-0524 / G 08.09.2010

Kongsberg Maritime

FleetMaster

%,
Installing FleetMaster on a computer connected to the DataChief process
network, FleetMaster Gateway in the diagram. The gateway can be used in an
installation together with clients.

*%

%,
Installing FleetMaster on a computer connected to the same administrative
network as a FleetMaster Gateway. The client is running ShipViewer, ShipTrend
and Remote files. Clients are described as Adm PC in the diagram. A client
installation will not start PdsConfig, PdsGW, FPG or ShipTask.

*(

%,
+Installing only the DC C20 ShipViewer is like the FleetMaster Gateway or
Client installation, but with a ShipViewer only option specified in the initial
configuration when FleetMaster starts for the firs time. The ShipViewer
installation will not start PdsConfig, PdsGW, FPG, Trend Logger, Trend
Manager or Ship Task.

CN-0524 / G 08.09.2010

Kongsberg Maritime

FleetMaster

The auto-run menu is automatically displayed when inserting the FleetMaster


installation CD if the auto-run feature is enabled on the computer. If auto run is
disabled, or the CD-files are on a memory stick or on a hard disk, you can
activate autoutorun.exe manually. It is located in the root folder of the CD.

Adobe Reader is required to read the installation manual from the CD. If
necessary, install this from the CD (\Utilities\Adobe) before proceeding with the
FleetMaster installation.
Components may be installed separately by going through steps 2-5 above, or
you may use the automatic setups program called InstallChecker
(recommended).
CN-0524 / G 08.09.2010

Kongsberg Maritime

FleetMaster

If you are prompted to reboot during installation, you will need to activate "Start
Automatic Setup" again to complete installation.

&

To install FleetMaster on computers running Windows 7, you need to have


administrator privileges. It may not be sufficient to be logged on as a domain
user who is also member of the administrator group. The setup may appear to
run without any problems, but you may get some error messages when the
InstallChecker program is executed.
You may get messages like Access denied from the operating system or you
may experience messages like this:

It is strongly recommended that you log on to the computer as an


administrator before trying to install FleetMaster on Windows 7.

It is also strongly recommended that you turn UAC (User Account Control)
off. Go to the Control panel. Select the System and Security category.
Then open the Change User Account Control settings dialog, select Never
notify and OK.

Remember to restart the computer after changing the UAC setting.


If you are logged on as a user without full administrator rights, you can still try
to install FleetMaster, but you need to run the setup as administrator. To do this,
proceed as described below.
If the main installation window (autotun.exe) is started automatically, you
must terminate it.
Then navigate to the root of the installation CD and find the program
called Autorun.exe. Right click the program and select Run as
administrator from the context menu and enter the administrator
username and password. After programs launched from the main
installation window will be executed as administrator and installation can
be carried out as described in this document.
For KC-500 installations, it is recommended to use the >Start Guided
installation option from the main window. See chapter 2.

CN-0524 / G 08.09.2010

Kongsberg Maritime

%%

1 2

FleetMaster

! 13

NB! - Windows 2000, XP or Win7 required


This chapter describes briefly the automatic installation program called
InstallChecker. This installation method is available from release 4.6.3 and up. If
you have an older version, you will need to run the manual installation as
described in chapters 3 -8. InstallChecker may be activated from the main
autorun screen or by double-clicking InstallStarter.exe in the InstallChecker
folder on the CD. Note that the installChecker will not run on Windows NT.

First the InstallChecker is installed.


Click next and finished.

After installation is finished, the InstallChecker is started.

As you click next and follow the steps of the wizard, you will be guided
through a complete FleetMaster installation. The steps are indicated on
the next page:
CN-0524 / G 08.09.2010

Kongsberg Maritime

FleetMaster

Installing components:

Setting up FleetMaster applications:

Verifying the installed components:

Checking the network configuration:

Checking communication:

Checking ShipViewer version:

When this procedure has been carried out, FleetMaster is installed and ready to use.
Please restart the computer and set up FPG- and trend logging according to your needs.
See chapter 8.2 for details on how to verify that FleetMaster is installed- and starting up
correctly.
CN-0524 / G 08.09.2010

10

Kongsberg Maritime

"! &2

FleetMaster

! 13

This section explains how to connect to the correct networks, process- and ship's
administrative network.

The FleetMaster Gateway computer is connected to the ROS B network as a


default.
If connected to the ROS A network please observe the following:
1 All IP addresses referred to in this manual as xxx.xxx.16.xxx must be
changed to xxx.xxx.17.xxx
2 A few entries in the fleetmaster.ini file must be changed manually :

AutoInit=Yes
Command=PdsGW.exe /ipaddra 0.0.0.0 /..

must be exchanged with

AutoInit=No
Command=PdsGW.exe /ipaddra 172.17.0.xxx /..

where xxx will be the Gateway address.

(%

(%

This section explains how to configure the FleetMaster Gateway network


connections.
/+
+
The network adapter connected to the process network must be configured to use
ip address 172.16.0.200 with subnet mask 255.255.0.0 for connection to the Bnet.
Make sure that the gateway computer only has one address in the ROS range.
This means that only one of the addresses 172.16.0.xxx (B-net) and
172.17.0.xxx (A-net) must be defined on any of the network adaptors on the
gateway. Having addresses for both A- and B-net on the same gateway will lead
to problems with data reception.

(%%

/+
"
++
The port forwarding application NetworkActiv needs a dedicated ip address to
read UDP in parallell with the PDS. Add the ip address 172.16.1.200 with subnet
mask 255.255.0.0 to the network adapter connected to the process network.

CN-0524 / G 08.09.2010

11

Kongsberg Maritime
(%(

FleetMaster
/+

This operation is a ship specific configuration and must be done after installation
when the configuration of the ship's administrative network is known. See
chapter 7.1.1.
(%)

4 %,,,5
On the Gateway Computer, open a Command prompt' window.
Type the command:
(Assuming MCU is on A
net)
or
(Assuming MCU is on B net)
You should then get response similar to
. or
At this point, the connection is working and you can start testing the Process
Gateway program itself.

(%*

4 6 %,5
On the Gateway Computer, open a Command prompt' window.
Type the command:
(Assuming ROS is on A
net)
or
(Assuming ROS is on B net)
You should then get response similar to
. or
At this point, the connection is working and you can try to copy files from the
ROS. You should be able to open a windows explorer and browse the disk on
ROS1. You can do this by selecting Start and Run in the windows start menu.
In the dialog box, enter ROS1 or its IP address and press OK.

For this to work you need to know the share name, username and password. After
logging in to the ROS, you should be able to see the share named C.

CN-0524 / G 08.09.2010

12

Kongsberg Maritime

FleetMaster

Now try to copy some of the files from the ROS\Config\Database folder. If this
is successful, you should be able to install, configure and run the FleetMaster
applications on the gateway computer.
If you have problems logging in
1. Verify that there is a share on the ROS named C
2. Verify that you have the correct username and password to access files
on the ROS computer.
3. Verify that simple file sharing is turned off on the ROS.
You do this by opening a windows explorer , select Tools/Folder
Options/View (tab) Then make sure the bottom choice (Use simple
filesharing) is unchecked.

((

((

This section explains how to configure the FleetMaster Client network


connection.
+2
Configuring to run only a ShipViewer is the same as configuring a gateway or a
client. The only difference is that you select Viewer only when FleetMaster is
started for the first time.
If you check the Connected to DataChief box, the rest of the configuration will
be as for a gateway.
If you do not check the Connected to DataChief box, the rest of the
configuration will be as for a client.

((% "
/+
/
This operation is a ship specific configuration and must be done after installation
when the configuration of the ship's administrative network is known. See
chapter 7.2.1.

CN-0524 / G 08.09.2010

13

Kongsberg Maritime

FleetMaster

(((
4 %,,,5
On the Client Computer, open a Command prompt' window.
Type the command:
( = the gateways IP address
)
You should then get response similar to

At this point, the connection is working and you can start testing the Process
Gateway program itself.
(()

4 6 %,5
On the Client Computer, open a Command prompt' window.
Type the command:
(= the
address)

gateways

IP

You should then get response similar to

.
At this point, the connection is working and you can try to copy files from the
gateway. You should be able to open a windows explorer and browse the disk
on the gateway. You can do this by selecting Start and Run in the windows
start menu. In the dialog box, enter GATEWAY or its IP address and press
OK.

For this to work you need to know the share name, username and password
needed to log on to the gateway. After logging in, you should be able to see the
share named FleetMaster.

CN-0524 / G 08.09.2010

14

Kongsberg Maritime

FleetMaster

Now
try
to
copy
some
of
the
files
from
the
GATEWAY\FleetMaster\Config\Database folder. If this is successful, you
should be able to install, configure and run the FleetMaster applications on the
client computer.
If you have problems logging in
1. Verify that there is a share on the GATEWAY named FleetMaster
2. Verify that you have the correct username and password to access files
on the GATEWAY computer.
3. Verify that simple file sharing is turned off on the GATEWSY. You do
this by opening a windows explorer, select Tools/Folder
Options/View (tab) Then make sure the bottom choice (Use simple
filesharing) is unchecked.

CN-0524 / G 08.09.2010

15

Kongsberg Maritime

FleetMaster

&." 2& 7380 "

%,,,

This chapter is relevant if you are installing a FleetMaster Client software for
DC 2000 on windows XP/SP2 or Windows 7 computers only.
DCOM setup is complicated in Windows XP SP2. DCOM (un)stability in
general is also a problem for running FleetMaster applications. This is why we
have stopped using DCOM. In stead we now install port forwarding software
from NetworkActive to supply FleetMaster clients with data from DataChief.
This works well for DC-C20, but for DC-2000 it is necessary for the clients to
request alarm summary and alarm history from DataChief. The port forwarding
software is not able to do this. This means that one of the solutions outlined
below must be used if more than one computer on the ship shall run FleetMaster
applications.
1

All computers that shall run FleetMaster applications are


connected directly to the process network and configured to
run as a FleetMaster GWs. This may not always be possible
(or practical) with respect to wiring and it is not allowed if
the computers also are connected to an administrative
network.

3 The FleetMaster computers may be connected to the process network


through a router that will isolate the process network from traffic from
the administrative network. This type of solution requires detailed
manual set-up and is not described in this manual. Please contact
Kongsberg Maritime for more details if you plan to use this solution.
If you have only one FleetMaster computer, or if all FleetMaster
computers are directly connected to the process network, the
above discussion does not apply.

CN-0524 / G 08.09.2010

16

Kongsberg Maritime

FleetMaster

. .2" # ! 13
Depending on the configuration of the FleetMaster installation, some additional
software installations and / or updates are required. Please install from the
chapters suiting your configuration only.

If the computer is supposed to be a gateway, the NetworkActiv port forwarding


application is required. This program opens a one way connection between the
DataChief system and the ship's administrative network. It will not compromise
the security aspect regarding access to the process network.
The gateway must also be set up to share the FleetMaster folder on the network.
"
Install the application from the main menu and follow the instructions:
1

If any kind of security alert is displayed during the installation process, the
NetworkActiv application must be unblokked / allowed access
4

Initially select Yes Continue to installation

Agree to the end user legal agreement

Leave the two first choices blank and check the last choice to install as a
service

A confirmation of a successful installation is displayed

CN-0524 / G 08.09.2010

17

Kongsberg Maritime

FleetMaster

The application must start automatically when the computer starts. To


configure open services.msc from the start->run menu. Find NetworkActiv
AUTAPF Service and right-click to enter the properties option. Change
startup type to automatic and click OK.

The NetworkActiv application is now installed and will be in operation


after a reboot later in the installation procedure

9
/
If you plan to connect one or more FleetMaster clients to the administrative
network, they must be able to copy configuration files from the gateway. This
happens automatically every time FleetMaster is started on the client. A batch
file will try to copy data from GATEWAY\FleetMaster\Config\Database. This is
only possible if the gateway is set to share those files. Please follow the
procedure below if you plan to connect clients to the administrative network.
1. Make sure that simple file sharing in windows is turned off. You do this
by opening a windows explorer (on the gateway computer). Select
Tools/Folder Options/View (tab) Then make sure the bottom choice (Use
simple file sharing) is unchecked.

CN-0524 / G 08.09.2010

18

Kongsberg Maritime

FleetMaster

2. Make sure the C:\FleetMaster folder (on the gateway) is shared using the
share name FleetMaster, giving everyone read access. From a windows
explorer, right click the C:\FleetMaster folder. Select Sharing and
Security. In the properties window ser sharing as shown below.

CN-0524 / G 08.09.2010

19

Kongsberg Maritime

FleetMaster

3. Open the permissions dialog and make sure all users have at least read
access. Click the Permissions button and give everyone read access.

4. Create a user named FleetMaster with a password that must be


remembered for future configuration of the clients. This is done by right
clicking on My Computer and selecting Manage. Then locate Users and

CN-0524 / G 08.09.2010

20

Kongsberg Maritime

FleetMaster

select New User from the pop-up menu that appears when you right
click in the right window pane.

5. The New User dialog appears.

Enter username and password for the new user. Be sure to check the box:
Password never expires

CN-0524 / G 08.09.2010

21

Kongsberg Maritime

*%

*%

FleetMaster

%,

/ +

The DataChief version 9 needs the .NET Framework. To install the framework,
the Microsoft Installer is needed.
.
(,
If this application is not installed or you dont know, start the installer from the
install CD main menu. If the installer is not needed, you will be informed with a
setup error message.

If the installer is required complete the installation.


This is only relevant for Windows versions up to and including XP.
* % % "!
If this application is not installed or you dont know, start the installer from the
main menu. If the installer is not needed, you will be informed with a
maintenance mode message.

If the framework is required complete the installation.


This is only relevant for Windows versions up to and including XP.

CN-0524 / G 08.09.2010

22

Kongsberg Maritime
*%( -

FleetMaster

;; * ,
++
DataChief version 9 and up also needs the Visual C++ redistributables to
be installed. Run setup from item 4 c on the CD. You must then accept the
license and the setup will run without further questions.

CN-0524 / G 08.09.2010

23

Kongsberg Maritime

<

<

<

9#!!

FleetMaster

! 13

When the network setup is complete and all the required applications are
installed, the FleetMaster Technical Log can be installed from the main menu.

If a previous version of FleetMaster is already installed on the computer, please


follow these instructions to upgrade the software.

)<%

For versions older than 4.6.2 and all versions of FleetMaster for DC2000, the following
upgrade procedure should be followed:
1. Remove the old FleetMaster installation (from Control panel/Add Remove
Programs). Also remove the Sentinel driver if it is installed. This applies to
installations older than year 2001 only.
2. Remove the c:\FleetMaster folder entirely from the disk. If you have valuable
data in the ShipData, ShipReport or ShipTrender folders, you should make a
backup first.
3. You should also make sure the files in C:\FleetMaster\ShipViewer is backed up.
You may need to restore them after installation if the K-Chief (DataChief)
version is older than Service Pack 10.03. For newer K-Chief versions, all
ShipViewer related files are copied from ROS1 when FleetMaster is restarted.
4. Follow the instructions in this manual to prepare the computer for installation
and install the FleetMaster application software.
5. If you are installing for DataChief 2000:
There is no need for patching as mentioned in the readme file in the installation
CD root. See : Manuals/CN-0533-B User Manual Network and NT Config.pdf
if you plan to use more than one FleetMaster PC. This is quite hard to do with
Windows XP Service Pack 2 and Windows 7.
6. After installation it is possible (but requires some manual work) to restore your
logged data from the backup if it is available.
All files in the ShipData folder may be replaced with your backed up folder.
All sub-folders in the ShipTrender folder may be replaced with the
corresponding folders from your backup - but not the files in the ShipTrender
folder itself.
7. If your previous version is 4.5.1 or older and you have used ShipTask to save
alarm history in C:\Fleetmaster\ShipReport\Logbook.mdb, these alarms will no
longer be available from the new shortcut to Logbook.exe on you desktop. The
new Ship Report (Logbook.exe) uses a different database table layout. The alarm
database will initially be empty after patching.
However, it is possible to view the old alarm database with the old version of the
program. You must then save the backed up ShipReport folder somewhere on
CN-0524 / G 08.09.2010

24

Kongsberg Maritime

FleetMaster

the disk (e.g. in C:\FleetMaster\oldalarms). Then make a new shortcut on the


desktop to the Logbook.exe file in that folder, or just activate the old program
from a windows explorer. The old database will not be updated with new alarms
and events. These will be stored in the new database :
C:\Fleetmaster\ShipReport\Logbook.mdb.

<

)<(

/ +

6 %,

If rel. 4.6.3 or higher is installed and the new version is 4.6.5 or higher, it will be possible
to upgrade without uninstalling the old FleetMaster first. This applies to FleetMaster for
DC-C20 only. For DC-2000 installations, the procedures in the previous chapter must be
followed.
1. As a precaution, you should always make a backup of the old installation before
an upgrade. Simply copy the entire FleetMaster folder (C:\FleetMaster) with
sub-folders to a memory stick or hard disk.
2. From the installation CD, run the FleetMaster Setup manually. See chapter 2
3. After installation all your logged data and ShipViewer (fltmimic.dll) will be
available as before the upgrade.

<%

++

The installation of the different modules should be specified in the project


specifications. Generally all modules are installed for the Gateway and the
Client, ShipViewer only for the Ship Viewer.
If any kind of security alert from the firewall is displayed during the
installation process, the FleetMaster application must be unblokked / allowed
access.
10 In the Welcome screen click next.
11 Insert name and company.
12 In Setup Type choose complete for gateway or client, custom for ShipViewer
or any other customized setup.
13 In a complete installation FleetMaster Gateway, ShipTrend, Engine Report
and Remote files are installed. If a customized installation is wanted, choose
the custom installation and exclude the different applications by clicking the
icon
in front of the module. If a ShipViewer only is wanted, the setup is
like the figure below.

CN-0524 / G 08.09.2010

25

Kongsberg Maritime

FleetMaster

14 When clicking next, the FleetMaster installation will be completed.

<(

If available on the installation CD, a patch is a set of add-ons and minor fixes
that is made between main releases. Please always check the installation CD for
a folder named Patches. Read the documentation and if necessary, install the
patch(es) as described.

CN-0524 / G 08.09.2010

26

Kongsberg Maritime

FleetMaster

9 ! ."

##

.2"

0
0

/+

Configure the second network adapter to be connected to the ship's


administrative network according to the ship's IP address directive. Notice that
this is the gateways network adapter for the ship's administrative network, not
the one connected to the process network.
0

%
1

//

Open the application Broadcast Calculator from the utilities folder on the
installation CD
15 Insert the IP address configured in chapter 7.1.1

16 The broadcast address for the Gateway to forward UDP on to the


administrative network is displayed.
0

"
++
NOTE! : Be aware that you must close >NetworkActive from the File/Exit
menu choice if you want to save the parameters you have changed.
Just closing the dialog box will not save the settings.
Open the application with one single click on the NetworkActiv icon in the
system tray.
17 Edit the first (and only) line in the port forwarding operations list.

CN-0524 / G 08.09.2010

27

Kongsberg Maritime

FleetMaster

18 Use the dropdown menu to set the local interface IP address to


172.16.1.200.

19 Insert the broadcast address calculated in chapter 7.1.2 in the Remote host
address field.

CN-0524 / G 08.09.2010

28

Kongsberg Maritime

FleetMaster

20 Click OK.
21 Then (with reference to the picture in item 2) - click the Start button for the
newly edited action.
22 From the menu select File and Exit.
23 Verify that the service still is running. (Ref chapter 5.1.1). Restart it if
necessary.
24 Reboot the computer to verify that the service is starting automatically. If a
ROS is connected to the process network, numbers indicating data transfer
are updated in the Network Active main window. When the computer
restarts, the FirstTime scrren will be activated. See section 8.

0%
0%

/+

Configure the network adapter to be connected to the ship's administrative


network according to the ship's IP address directive.

CN-0524 / G 08.09.2010

29

Kongsberg Maritime

0(

FleetMaster

This chapter applies to DataChief versions 9 only.


NB! On the installation CD for rel 4.6.1 there is a patch called Patch v10 that
does this automatically.
Different DataChief versions use different files for starting the Process Database
Server (PDS) and ShipViewer. This makes it necessary to copy different files for
different versions into the FleetMaster folder. For older versions (up to and
including version 8) this is handled automatically by the FirstTime.exe program.
DataChief (and ShipViewer) version 9.0.2 is the latest available at the time of
FleetMaster 4.6.0 release. There are a few issues that must be observed when
installing version 9.
Version 9.0.0
When you select version 9 in FirsTime.exe, PDS and ShipViewer files for
DataChief version 9.0.0 will be installed. If you are running this DataChief
version, no further modifications need to be carried out.
Version 9.0.1 and up..
For DataChief versions 9.0.1 and up, some files must be replaced after
installation of FleetMaster. The patch named PatchV10 does this automatically.
If the patch is not available files must be copied manually as described below,
preferably before starting up FleetMaster for the first time. Both
ProcessGateway files and ShipViewer files must be copied. The
ProcessGateway may be copied from ROS1. One must then search
c:\ros\basic\bin and c:\ros\basic\sys for the necessary files.
NB! The description below is a manual procedure corresponding to the Patch
v10. It is not necessary to do this if you run the patch or if you have
FleetMaster release 4.6.2 or higher.
Copy ProcessGateway files:

1. Locate the DCC20\ProcessGateway folder on the installation CD.


2. Find the subfolder for the actual version you are running (here v9.0.2)

CN-0524 / G 08.09.2010

30

Kongsberg Maritime

FleetMaster

3. Copy all files from this folder (DCconfig.exe, PdsConfig.exe, DZF.dll


and OD.dll ) into
c:\FleetMaster\ProcessGateway, overwriting all existing files.
4. Copy the same files into the actual version folder under
ProcessGateway, here c:\FleetMaster\ProcessGateway\V9,
overwriting all existing files.
If item 4 above is ignored, the version specific files will be over-written by the
one from the .\V9 folder if FirstTime.exe is run again.
Copy ShipViewer files:

5. Make sure you have a copy of the fltmimics.dll file in case you delete
the original by accident.
6. Delete all files from c:\FleetMaster\ShipViewer (except for
fltmimic.dll if it exists)
7. Locate the DCC20\ShipViewer folder on the installation CD.
8. Find the subfolder for the actual version you are running (here v9.0.2)
9. Copy all files (except mimics.dll) from this folder (Viewer.exe,
sfl201as.dll, og901as.dll) into c:\FleetMaster\ShipViewer.
10. Copy the same files into the actual version folder under ShipViewer,
here c:\FleetMaster\ShipViewer\V9, overwriting all existing files.
If item 4 above is ignored, the version specific files will be over-written by the
one from the .\V9 folder if FirstTime.exe is run again.

0)

+-

For KC-500 / 10.03 and up, all Ship Viewer related files shall be located in the
\\ROS1\ShipViewer folder and will be copied automatically to the FleetMaster computer
when restarting. For older versions of K-Chief /DataChief, obtaining the correct
Viewer.exe version and files it depends on is a manual task. Please see the next
paragraphs for more details.

0)

If
available,
copy
the
project
specific
fltmimic.dll file
into
the
C:\Fleetmaster\ShipViewer\V6, V7, V8, V9 or V10 folder, depending on what version of

CN-0524 / G 08.09.2010

31

Kongsberg Maritime

FleetMaster

DataChief you have. It is important that this action is carried out before running the
application for the first time.
0)%
+For older DataChief versions new mimic pictures (fltmimic.dll) that shall replace
previous ones must be copied to two different folders on the FleetMaster computer.
1. c:\FleetMaster\ShipViewer
2. The current DataChief /ShipViewer folder, e.g:
c:\FleetMaster\ShipViewer\V9
If item 2 above is ignored, the new fltmimic.dll will be over-written by the one from the
.\V9 folder if FirstTime.exe is run again.

0*

To complete the FleetMaster setup, the computer should be restarted.


The computer should be restarted for the applications to run properly and to have a visual
confirmation that everything is according to the project specifications.
Make sure that files are copied from ROS1 as intended both when rebooting the computer
and when restarting FleetMaster without rebooting. This can be checked by deleting all
files in the C:\FleetMaster\Config\Database folder and perform the reboot/ restart.

CN-0524 / G 08.09.2010

32

Kongsberg Maritime

9#!!

FleetMaster

13

For releases prior to 4.6.3; when FleetMaster is started for the first time, the
FirstTime screen will open. It will appear this time only for an initial
configuration. This dialog will differ from release to release. The example below
is for release 4.6.2. The program may be activated again from the Start
Menu/FleetMaster/Start.
On newer versions of FleetMaster the process described below is handled by the
InstallChecker application.

Select Gateway, Client or Viewer only.


25 If a Viewer-only is connected to the process network, check the checkbox for
the connection to the C20. If a Viewer-only is connected to the ship's
administrative network, do not check for the connection to the C20. This
option will configure the location of the database to be copied.
26 If a Viewer-only is connected to the ship's administrative network enter the
name of the Gateway computer. The FleetMaster Gateway name is
GATEWAY as a default.
27 Check the correct DataChief version.

CN-0524 / G 08.09.2010

33

Kongsberg Maritime

FleetMaster

28 Select what applications (FPG, Trlog, ShipTask) you want to start


automatically when FleetMaster is started.
29 Select whether or not the Remote Recorder and RunAndDelete is to be started
automatically. These are application needed for sending information to and
receive commands files from land office.
30 The Synchronize time with DC-C20 is enabled as default.
Click OK to confirm. If you have installed FleetMaster for DC-C20, the
password dialog appears. You must enter user name and password for the
computer where the DataChief database files are to be fetched. The dialog
box is different if you are connected to the process network or not.
If you are connecting to the process network it looks like this:

Here you must fill in all fields. Normally the default values are the correct
ones. Only username and password must be filled in.
On the administrative network, it looks like this:

CN-0524 / G 08.09.2010

34

Kongsberg Maritime

FleetMaster

Share name is hard coded to FleetMaster and the Ros Path is not used.

+ /

NB ! This chapter is relevant for releases up to and including 4.6.1 On later


releases, the database is copied automatically when FleetMaster is restarted.
The GATEWAY FleetMaster needs the database from the ROS to function
properly. The Client FleetMaster needs the database from the gateway. If the
database update does not succeed due to problems with connection to ROS or
GATEWAY, an error message will be displayed and the start-up will terminate.
This requires manual interaction and needs to be carried out before restarting the
FleetMaster applications.
1

To open the ROS1 file system, type \\ROS1 in the start->run menu. If the
file system does not support name resolution, the IP address has to be
typed instead of the computer name. In this case that would be
\\172.16.0.101 (B net).

The database is located in C:\Ros\Config\Database on the ROS computer.


Copy all files inside the database folder and paste into the
C:\FleetMaster\Config\database folder on the FleetMaster computer.

CN-0524 / G 08.09.2010

35

Kongsberg Maritime
3

FleetMaster

The database copy operation is complete and FleetMaster should be


restarted.
The procedure for copying manually to a client is similar to the description
above, but you must use other computer names/addresses of course.

&

"

Please note that the original batch files that copies the database
(GW_CopyDB.bat and Client_CopyDB.bat) are designed for use with Windows
2000/XP. They must be modified or replaced to work with Windows NT.
A set of batch files for NT is located on the installation CD, in the Win_NT
folder. Please copy the two batch files manually to the c:\FleetMaster\Tools
folder after installation of FleetMaster.

=%

6 +

Each time FleetMaster is restarted, a start-up log is generated. Rel 4.6.3/4.6.4


make the file C:\FleetMaster\startup.log. Later releases make the file
C:\FleetMaster\ConfigReport.txt.
After installation and restart, it is important to inspect this file for any error
messages. In particular, the
!" " "
#
- section
must be inspected to verify that files are copied correctly.
This will verify that:
the network is set up correctly
user name and password for logging on to the remote computer (ROS1 or
GATEWAY) has been correctly entered
file sharing is set up correctly on the remote computer

The section should look approximately like this:


$$$$
'"

!" " "


%" " &
) ! *
+
, - #1/ 0203/43 45
3& 6
" ! 6
! +66
+

$$$$$$$$$

%" " "


%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
%" " "
: ; 6
%" " "

CN-0524 / G 08.09.2010

"

#+

"

#./0

54728 924
6 +
8 +
1
! "
7 3" 0 " 6%
7 3" )%
! +
" % " 6
" ' 6
" "
" 0
" 0 " 6
!
0.03/' 78

36

Kongsberg Maritime

FleetMaster
: ; 6
%" " "

3&

4"* " <


&
6
!
: ; 6
!
6 9
% 54728 /=/
: ; 6
!
6 9
1!
: ; 6
!
6 0
%>7 !
: ; 6
!
6 0
5% !
: ; 6
!
9
< !
6"
! &
6
!
: ; 6
!
1 6 +
"!
: ; 6
!
(
" !
(
" !
(
,@=3&
0 !
(
" !
: ; 6
!
(
? (
: ; 6
!
(
A'B! 4
4"* "
: ; 6
!
!" " "
!
$$$$$$$$$
6"

9"
9"
9"
9"
3&

0&
0&
0&
0&

?
?
?
?

0&

0&

$$$$

!
!

As can be seen from the log, some of the files are not found. This is normally
no problem as these files already may be on the FleetMaster Computer.
Things to look out for are messages like this:
$$$$
'"
+
0
3&

or:

6"

!" " "


%" " &
) ! *
) 6 #+
"!
50
- &"
66+
!

! * 6

'"

+
$$$$ @ "

"

) ! *
A'$
A'
$50
" !

"

"!

"
4

$$$$$$$$$
$$$$$$$$$
"

#./0 #1/ 0203/43 45

!
)

#+

0203/43
203/43 45
#./0 #1/ 0
"! +
" # " ( !

The rest of the start-up section should look like this.


$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$

-$
-$
-$
-$
-$
-$
-$
$
-$
-$
-$
-$
-$
-$
-$
-$
-$
-$

& 6)
0
0
2
"
2
"
0 "
$ 1

!" "
7
7
C 1
C 1
+
D 1

0 "
+
7
'"
0 "
+
0 "
+
0 "
+
4
0 "
4
0 "
4
0 "
0"*
21$6

"
% $
'"
$ ("
'"
$ !
6
%" " "
0 *
:1!
6
%" " "
0 *
:1!
%" " 0 *
8" (" :1! 8(
- #
#

%" " 0 *
8" (" :1! 8(
0&
8" (" $ ("
0&
E
:3
; $ ("
3
! '" "
:3
! "
3
! '" "
:3
! "
0&
3" ) $ ("
+ F !%
$ ("
6 !
$ ("
+ "
$ ("

Depending on your configuration, the entries in the log may differ


somewhat form the example above. The most important thing to notice
here is that the project number is listed in the log. There should be no
spaces in the project number string: 1
- #
#
CN-0524 / G 08.09.2010

37

Kongsberg Maritime

FleetMaster

Errors in the log or other problems?


If you are experiencing problems of any kind with the FleetMaster
Applications or ShipViewer, please go through the steps listed below to
generate files with some useful troubleshooting information.
1

Run the InstallChecker again and pay attention to all test results in all
steps of the program. Correct make the necessary corrections and
repeat the tests until all are succefull.
NB! In the last step, remember to click the Save button before
terminating the program.

For releases before 4.6.5, a file version.log must be generated


manually. That can be done form the Windows Start menu - (All)
Programs/ FleetMaster/Tools/FileVersions. Start the program from the
menu and click the Save button before closing the dialog.

Restart FleetMaster. This will update the information in


Fleetmaster.ini. Inspect the startup.log for errors as described above.

Now the following files have been updated in the C:\FleetMaster folder:
InstallReport.txt
Startup.log
Fileversion.log
FleetMaster.ini
ConfigReport.txt (4.6.5 and up)
If you need assistance analysing these files, they can be sent to KM
Customer support for investigation. ConfigReport.txt contains Startup.log,
InstallReport.txt, Fileversion.log and more. So if ConfigReport.txt exist, this
is the only file that you need to send (4.6.5 and up). For older versions, the 3
other files are needed.