E8 - BFD PFD P&id
E8 - BFD PFD P&id
E8 - BFD PFD P&id
DavideManca
Lab5 ofProcessSystemsEngineering MasterDegreeinChemicalEngineering PolitecnicodiMilano
E5
Therearethreemaindiagramsusedbychemicalengineerstodesignand
describetheprocesses
BlockFlowDiagramBFD
Startingfromaninputoutputdiagramoftheprocesswedivideitintoitsmain
functionalblockssuchas:thereactionsection,theseparationsection,etc
Thenweaddtherecyclestreamsandthepreliminarymaterialbalances.
ProcessFlowDiagramPFD
Thenextstepistoevaluateandquantifyefficientlythematerialandenergy
balancesforalltheprocessstreams.Thenweaddthepreliminarydesign
specificationsoftheequipment.
PipingandInstrumentationDiagramP&ID
Weintroducethespecificdetailsdescribingthemechanicsandtheprocess
instrumentation.
E52
Themostefficientwaytocommunicateinformationrelatedtoachemical
processistouseflowcharts.Visual informationisthebestwaytopresent
designdataanditavoidsmisunderstandingsandambiguities.
WhenpossibleitshallbeadoptedtheEnglishterminologyandsymbologysince
inmostcasesthedocumentationproducedbyanengineeringcompanyisfor
foreignorders.
Werefertosymbolsanddiagramsfromthetext:
R.Turton,R.Bailie,W.Whiting,J.Shaeiwitz
Analysis,SynthesisandDesignofChemicalProcesses
PrenticeHall,NewJersey,1998
E53
Reaction:C7H8+H2=C6H6+CH4
InternationalconventionsandrecommendedformatsfortherealizationofBFDs
Theunitoperationsareindicatedbyblocks
Themainstreamsareidentifiedbylineswitharrowsindicatingtheflowdirection
Whenpossible,thedirectionofthestreamsisfromlefttoright
Lightcurrents(gas)upwards,heavycurrents(liquidsandsolids)downwardsoftheblocks
representingthesingleportionsoftheplant
Providebasicandmostimportantinformationoftheprocess
Iftheprocesslinesintersect,thehorizontalonesareheldwhilsttheverticalonearebroken
Providesimplifiedmaterialbalancesandmainreactions
E54
ThePFDisgreatlyenhancedcomparedtotheBFD.Itisthemostimportantandused
diagramtodescribewithanadequatelevelofdetailthestructureoftheprocess.
Thereisnotauniversallyacceptednomenclature.Ingeneral,aPFDcontainsthe
followinginformation:
1.
Theimportantequipmentisshowntogetherwithashortdescription.Eachdeviceis
identifiedbyacode.
2.
Thestreamsareshownandidentifiedwithanumber.Everystreamshowstheprocess
conditionsandcomposition.ThesedatacanbeentereddirectlyonthePFDorina
summaryattachedtable.
3.
Theutilities oftheequipmentareshownanddescribed
4.
Themaincontrolloopsareshown
TheinformationprovidedbyaPFDcanbesummarizedasfollows:
Topologyoftheprocess
Informationonstreams
Informationonequipment
E55
PFDfortheproductionofbenzenebythehydrodealkylationoftoluene(HDA)
E56
Wedefineastopologyoftheprocessthepositionandtheinteractionamongthe
unitsandthestreamsoftheprocess.
Theequipmentisrepresentedbyicons.TheASME (AmericanSocietyofMechanical
Engineers)periodicallypublishesalistofsymbolstobeusedintheproductionofthe
PFD.Nevertheless,engineeringcompaniesareusedatadoptingcustom symbolsin
ordertomaketheirownPFDrecognizableanddistinguishablefromthoseoftheir
competitors.
EachpieceofequipmentisidentifiedbyanumberonthePFD.
Forexample,thetoluenepumpP101A/B providesthefollowinginformation:
P101A/Bmeansthattheequipmentasapump
P101A/Bmeansthatthepumpislocatedinthearea100 oftheplant
P101A/Bmeansthatthespecificpumpisnumber01 ofthearea100
P101A/B meansthattherearetwopumps:P101A andP101B.Thesecondone
isasparepartthatworksasabackup(i.e. normallyisnotworkingbutitstarts
runningwhentheformerbreaksorneedstobeserviced).
ThewordToluenepumpisthecolloquialnamethatidentifiesP101andisused
indiscussionsabouttheprocess.
E57
LibraryofequipmentsymbolsforaPFD
DavideManca ProcessSystemsEngineering MasterDegreeinChemEng PolitecnicodiMilano
E58
Generalformat:XXYZZ A/B
XX aretheidentificationlettersfortheclassificationoftheequipment
C Compressor,turbine
E HeatExchanger
H FiredHeater
P Pump
R Reactor
T Tower
TK StorageTank
V Vessel
Y showstheareaoftheplantwheretheequipmentisplaced
ZZ reportsthesequentialnumberofthespecificprocessunit
A/B meansaparallel/spare/backupequipment
E59
Eachprocessstreamisidentifiedbyanumberinadiamondaboveit.Thedirectionis
definedbyoneormorearrows.
Theutilitiesinclude:electricity,compressedair,coolingwater,chilledwater,steam,
condensate,inertgas,chemicalsewer,watertreatmentandflares.Weusethe
followingsymbols:
lps
mps
hps
htm
cw
wr
rw
rb
cs
ss
el
ng
fg
fo
fw
lowpressuresteam35barg(sat)
mediumpressuresteam1015barg(sat)
highpressuresteam4050barg(sat)
heattransfermedium(organic):to400C
coolingwater:fromcoolingtower30Creturnedatlessthan45C
riverwater:fromriver25Creturnedatlessthan35C
refrigeratedwater:inat5Creturnedatlessthan15C
refrigeratedbrine:inat45Creturnedatlessthan0C
chemicalwastewaterwithhighCOD
sanitarywastewaterwithhighBOD
electricenergy(specify220,380,440,660Vservice)
naturalgas
fuelgas
fueloil
firewater
E510
Streamnumber
Temperature[C]
Pressure[bar]
VaporFraction
TotalMassFlowRate[kg/h]
TotalMoleFlowRate[kmol/h]
IndividualComponentFlowRates[kmol/h]
Optionalinformation
ComponentMoleFractions
ComponentMassFractions
IndividualComponentFlowRates[kg/h]
VolumetricFlowRates[m3/h]
SignificantPhysicalProperties:Density,Viscosity,
ThermodynamicData:HeatCapacity,Enthalpy,Kvalues,
Streamname
E511
Towers
Heat Exchangers
Tanks, Vessels
Pumps
Compressors
Actual inlet flow rate, Pressure, Temperature, Driver type, Shaft power,
Materials of construction
Heaters (fired)
Others
E512
The PFD can include explicit information of the process streams by means of special flags. These
flags are attached to the streams which they refer to, with text boxes in different shapes to indicate
the value of measures such as:
STREAMID
PRESSURE
MOLARFLOWRATE
TEMPERATURE
LIQUIDFLOWRATE
MASSFLOWRATE
GASFLOWRATE
DavideManca ProcessSystemsEngineering MasterDegreeinChemEng PolitecnicodiMilano
E513
E514
P&ID
Fieldinstrumentation
Positioningoftheinstrumentation:
InstrumentationonthefronofControlPanelin
thecontrolroom
InstrumentationonthebackofControlPanelin
thecontrolroom
Meaningofidentifyingletters
XYY
First letter: X
Analysis
Burner flame
Conductivity
Voltage
Flowrate
High
Current
Indicator
Power
Control station
Level
Light or low
Moisture or humidity
Middle or intermediate
Orifice
Alarm
Control
Element
E515
P&ID
Meaningofidentifyingletters
XYY
First letter: X
Pressure or vacuum
Quantity or event
Radioactivity or ratio
Record or print
Speed or frequency
Switch
Temperature
Transmit
Viscosity
Weight
Well
Relay or compute
Drive
Y
Z
Position
Point
Identificationofinstrumentalconnections
Capillary
Pneumatic
Electric
DavideManca ProcessSystemsEngineering MasterDegreeinChemEng PolitecnicodiMilano
E516
P&ID
E517
P&ID
LoopcontrolstructureforthetanklevelV102
LE
LT
leveltransmitterpositionedonthetankV102
Transferthesignalviaanelectricline tothecontrolroom
LIC
levelindicatorandcontrollerinthecontrolroom
Transferanelectricalsignal totheinstrumentLY
LY
instrumentabletocalculatetheexactvalveopening
Transferapneumaticsignal(solidline)tothecontrolvalveLCV
LAH
toohighlevelalarminthecontrolroom(frontpanel)
LAL
toolowlevelalarminthecontrolroom(frontpanel)
levelsensorpositionedonthetankV102
E518
E519
References
R.Turton,R.Bailie,W.Whiting,J.Shaeiwitz,Analysis,SynthesisandDesignofChemicalProcesses,Prentice
Hall,NewJersey,1998
E520