Max - E2: Low Voltage 3-Phase Induction Motors 0.18kW To 185kW
Max - E2: Low Voltage 3-Phase Induction Motors 0.18kW To 185kW
Max - E2: Low Voltage 3-Phase Induction Motors 0.18kW To 185kW
MAX - E2
Contents
page
PRODUCT DETAILS
General Information
Electrical Design and Standards
Altitude
Ambient
Direction of Rotation
Duty Rating
Electric Supply
Motor Types / MEPS
Performance
Standards
Stator and Windings
Testing
Variable Speed Drive Suitability
Winding Protection
Mechanical Design and Standards
Balance
Bearing and Lubrication System
Bearing Lubrication Instructions
Bearing False Brinelling Protection
Cooling System
Finish
Hardware
MAX-E3 H66
Mounting
Motor Construction
Protection
Rating Plate
Rotor Assembly
Terminal Box
Maximum Cable Sizes
Options
Performance Data MAX-E2 Range 63 ~ 315M
Outline Dimensions Frame 63 ~ 132 Foot Mount
Outline Dimensions Frame 160 ~ 250 Foot Mount
Outline Dimensions Frame 280 ~ 315M Foot Mount
Outline Dimensions Frame 63 ~ 132 Flange Mount
Outline Dimensions Frame 160 ~ 250 Flange Mount
Outline Dimensions Frame 63 ~ 200 Foot and Flange Mount
Outline Dimensions Frame 225 ~ 315M Foot and Flange Mount
Outline Dimensions Frame 63 ~ 132 Foot and C Face Mount
page
TECHNICAL DETAILS
2
2
2
2
2
2
2-3
3
3
3
3
3
3
4
4
5
5
6
6
6
6
6
6
6
6
7
7
7
7
8~9
10
11
12
13
14
15
16
17
Mechanical Design
Axial / Radial loadings
Cooling
Force Cooling IC416
Mounting (IM code)
Mounting - Cast Iron Slide Rails (dimensions)
Protection (IP code)
Electrical Design
Altitude and Ambient Temperature
Anti-condensation Heaters (optional)
Connection Diagrams
Duty
Formulae and Conversion
Insulation Classes
Speed vs. Torque Current
Starts per Hour
Maximum Load Inertia
Thermal Protection
Thermistors
Resistance Temperature Detectors
Tolerances for electromechanical characteristics
Variable Speed Drives (VVVF)
Voltage and Frequency during operation
Driving and Connecting Globally.
Motors
Motors
Drives
Drives
Controls
Controls
www.teco.com.au
18
19
20
21
21
22
23
24
24
24
25
26
26
27
27
28
28
29
30
31 ~ 32
33
RETURN TO INDEX
Welcome to
TECO Australia
Electric Motor Division
Teco!
Quality Assurance
All TECO manufacturing plants and
TECO Australia have been assessed to
meet the requirements of ISO9001:2008
ISO 9001
Lic QEC3088
SAI Global
accreditation.
one
RETURN TO INDEX
General Information
The motors described in this catalogue are
designed and manufactured by TECO Electric &
Machinery Co. and are Squirrel Cage Induction
Motors intended for general purpose industrial /
arduous mining applications and meet all relevant
sections of the Australian, New Zealand and
International Standards detailed herein.
two
Duty Rating
All motors have a maximum continuous duty
rating of S1 to AS60034-1. Other duty ratings are
available on request.
Electric Supply
Stock motors are designed for operation on a
380 ~ 415 Volt 3-Phase 50 Hz supply and are also
suitable for a 440~480 Volt 3-Phase 60 Hz supply.
Motors 4 kW and below are 380 ~ 415 Volt 50 Hz
STAR connected and may also be reconnected to
240 Volt 3-Phase 50 Hz DELTA configuration for use
with single phase input inverters.
Motors 5.5 kW and larger are 380 ~ 415 Volt
50 Hz DELTA connected.
Please refer to page 24 for Connection diagram.
Motors can be manufactured for supply systems
of up to 1100 Volts, 50 or 60 Hz on a factory made to
order basis or by local rewind / wind.
Motor Types / MEPS (Minimum Efficiency
Performance Standard)
All motors meet or exceed the requirements of
Australian New Zealand Standard AS/NZS1359.52004 3-Phase cage induction motors high efficiency
and minimum efficiency performance standards
requirements within the range of 0.75 kW to less
than 185 kW, 2 4 6 & 8 pole single speed, rated
S1 continuous duty, compliance as detailed herein.
RETURN TO INDEX
Frame
Size
Output
kW
Name
plated
Efficiency
Level
AEEB-NE
D63 ~ D90L
< 0.75
TECO
Not applicable
0.75 ~ 185
TECO
MAX-E2
MEPS table B2
or B3 as
nominated
Performance
Motors are designed to meet the performance
requirements of Design N as per AS1359.41, normal
torque for Direct On Line starting.
Testing
In addition to a full program of tests during
manufacture each motor is subjected to routine
refer to TECO.
Standards
Winding Protection
three
RETURN TO INDEX
Poles
DE Bearing
NDE
bearing
Greasing/
Shaft Seal
D63 ~ D90L
Ball
Ball
D100L ~ D160L
Ball
Ball
Greased
for life (GR)/
Gamma***
D180M ~ D250M
Ball
Ball
Grease relief
D280S ~ D355*
Ball
Ball
Grease relief
brass dust flinger
D63 ~ D90L
4 and Above
Ball
Ball
D100L ~ D132M
4 and Above
Ball
Ball
Greased
for life (GR)/
Gamma***
D160M ~
D180M/L
4 and Above
Ball (Roller)
Ball
Greased
for life (GR) /
Gamma***
D200L ~ D225M
4 and Above
Ball (Roller)
Ball
Grease relief/
Gamma
D250S ~ D250M
4 and Above
Roller (Ball)
Ball
Greased relief/
Gamma
D280S ~ D315M
4 and Above
Roller (Ball)
Ball
Grease relief/
brass dust flinger
four
RETURN TO INDEX
8 Pole
6 Pole
4 Pole
2 Pole
6210
63XX
12
72XX
13
73XX
14
2000Hrs
1000Hrs
15
3000Hrs
16
720Hrs
17
2000Hrs
18
20
22
24
1500Hrs
26
2000Hrs 1000Hrs
Bearing Number
NU2XX
NU214
NU3XX
15
8 Pole
6 Pole
4 Pole
2000Hrs
16
17
18
3000Hrs
1500Hrs
20
22
1000Hrs
24
26
2000Hrs
500Hrs
Amount
(grams)
Bearing
Number
Amount
(grams)
62XX
6210
30
63XX
6310
72XX
12
40
73XX
12
40
60
NU2XX
13
50
NU3XX
13
80
14
50
14
80
15
60
15
100
16
60
16
100
17
80
17
120
18
80
18
120
20
100
20
160
22
120
22
220
24
120
24
270
26
300
Extensive shaft
locking clamp on
D280-315M
TECO motor
five
RETURN TO INDEX
Cooling System
Cooling is Totally Enclosed Fan Cooled (TEFC), with
integrally cast cooling fins on frame and endshields,
fitted with external fan (IC411) to AS60034-7.
The cooling fans are bi-directional and low noise
as standard.
Finish
All external components are shot blast to a near
white finish. A durable coat of Alkyd Resin primer
giving excellent corrosion protection follows this
preparation. The complete motor is then finish
coated with Alkyd Resin Gloss Enamel in TECO Grey
(Munsell 7.5BG 4/2).
Other paint systems and colours are available
upon request, including chemical duty two pack
epoxy paint systems.
Hardware
All hardware is electro zinc plated for better
corrosion resistance.
Stainless steel hardware can be offered as an
alternative, please contact TECO for the surcharge
to provide this feature.
MAX-E3-H66
Please refer to separate catalogue for details
on TECO High Efficiency MAX-E3-H66 motors.
Motor Construction
Motor frames are high grade Cast Iron with
integrally cast feet and cast iron end shields, suiting
mining applications.
Castings are machined to close tolerances in
order to ensure accurate alignment with minimum
vibration.
Standard Materials of Construction
Frame Size
External Fan
Fan Cover
Terminal Box
D63~D160
CPP (CI)
HDPS (CI)
CI
D180 (2 pole)
CPP (CI)
HDPS (CI)
CI
D180 (4 pole)
CI
HDPS (CI)
CI
D200~D315M
CI
HDPS (CI)
CI
D80~D132
CPP (CI)
HDPS (CI)
CI
D160~D315M
CI
HDPS (CI)
CI
Mounting
Motors are available in the following mountings,
refer to page 21 for IM codes of mountings.
Foot mounted
Foot and Flange mounted
Flange mounted
Foot and C Face mounted
C Face mounted
six
RETURN TO INDEX
Rotor Assembly
Terminal Box
D63 ~ D71
2.5 mm
D80 ~ D112
10 mm
D132 ~ D180
50 mm
D200 ~ D225
95 mm
D250 ~ D315M*
185 mm
Induction Brazing
Options
Some available options in this range are as follows:
Airstream rated IC418
Anti-condensation heaters
Auxiliary terminal boxes for Thermistor /
Heater / RTD terminations
Electromechanical fail safe Brake Motors
Cooling Tower application
Crane rated motors
Double / non standard shaft extensions
Encoder / Tacho
Force ventilation IC416
Induction Generators
Insulated bearing
IP66 enclosure
Multi-speed motors
Resistance temperature detectors (RTDs)
winding and / or bearings
Rotor Groundary brush
Smoke spill to BS7436 to 185 kW
Special paint systems / colours
Stainless steel fasteners
Thermistor protection (on motor frames <D160)
Others on request
TECO AUSTRALIA PTY LTD
seven
RETURN TO INDEX
0.37
0.55
0.75
1.1
1.5
2.2
5.5
7.5
Notes:
eight
1.
2.
3.
4.
5.
6.
7.
Power Factor
Full
Load
(%)
3/4
Load
(%)
1/2
Load
(%)
Current
Torque
Inertia
Noise Weight
Full Locked Full Locked Pull Break- Rotor MaxLoad Level Foot
Load Rotor Load Rotor Up
Down J=GD2/4 J=GD2/4 dB(A) Mount
(A)
(%)
N-m %FLT %FLT %FLT Kg-m2 Kg-m2
Kgs
2740
63
61.0
59.5
55.0
77.5
69.0
57.0
0.55
455
0.63
330
330
330
0.0005
0.022
52
1350
63
63.5
63.0
58.0
70.0
61.0
49.0
0.58
431
1.27
240
230
260
0.0008
0.103
48
11
910
71
61.0
57.0
50.0
64.0
55.0
44.0
0.66
379
1.89
260
240
280
0.0018
0.175
45
12
705
80
52.0
48.0
39.0
47.0
41.0
34.0
1.06
302
2.44
360
350
370
0.0025
0.543
44
16
2800
71
75.0
74.0
70.0
85.0
78.0
64.0
0.81
593
1.26
320
270
310
0.0008
0.043
54
12
13
1405
71
74.5
73.0
68.5
69.5
60.5
48.0
1.00
530
2.51
325
270
305
0.0013
0.198
50
920
80
72.5
72.0
68.5
72.0
62.5
49.0
0.99
535
3.84
230
215
240
0.0025
0.338
49
18
710
90S
70.5
68.0
62.5
60.0
51.0
39.5
1.23
388
4.98
195
190
265
0.0045
1.04
49
22
2780
71
73.0
72.0
68.0
83.0
75.0
62.0
1.28
563
1.89
300
260
280
0.0008
0.062
53
16
1405
80
71.5
70.5
65.0
74.0
65.0
52.0
1.47
524
3.74
260
230
280
0.0018
0.291
48
18
910
80
68.0
68.0
63.0
72.0
62.0
49.0
1.59
365
5.77
230
210
230
0.0030
0.498
48
18
690
90L
70.0
70.0
66.0
70.0
61.0
49.0
1.59
365
7.61
170
145
205
0.0058
1.54
47
27
2860
80 **
83.0
82.0
79.0
85.0
78.5
65.5
1.47
1,020
2.50
340
340
380
0.0015
0.081
57
18
1420
80
82.5
82.5
80.5
71.0
61.0
47.0
1.77
678
5.04
330
320
330
0.0028
0.353
50
18
940
90S
78.0
78.0
75.0
67.5
58.0
46.0
1.97
609
7.62
200
200
250
0.0048
0.913
54
25
695
100L
76.5
76.5
73.0
60.0
51.0
39.0
2.26
442
10.3
230
215
230
0.0088
1.89
49
31
2840
80 **
84.5
84.0
82.0
87.5
82.0
70.5
2.11
947
3.70
300
290
330
0.0018
0.110
53
21
1415
90S
84.0
85.0
84.0
80.0
72.5
60.0
2.32
690
7.42
250
215
270
0.0043
0.523
46
27
940
90L
82.0
80.0
77.0
69.0
60.0
48.0
2.75
582
11.2
240
230
290
0.0063
1.40
42
26
695
100L
78.0
79.5
77.0
64.5
55.5
43.0
3.09
485
15.1
210
200
215
0.0113
2.74
49
37
2855
90S
85.0
85.5
83.0
85.5
80.5
68.0
2.86
804
5.02
330
300
330
0.0028
0.145
54
24
1430
90L
85.0
85.0
83.0
75.0
66.5
53.0
3.26
706
10.0
300
240
310
0.0058
0.670
46
30
930
100L
83.0
83.0
81.5
78.0
71.5
60.0
3.21
623
15.4
240
200
250
0.0138
1.83
44
36
705
112M
79.5
79.0
77.0
59.0
49.0
39.0
4.43
451
20.3
200
170
230
0.0150
3.65
49
45
2855
90L
86.0
86.5
85.5
88.0
83.0
72.0
4.11
803
7.36
320
290
330
0.0038
0.213
59
29
1440
100L
86.5
86.5
85.0
82.5
76.0
63.5
4.36
757
14.6
290
250
300
0.0103
1.04
46
37
955
112M
84.5
85.0
83.0
74.5
67.0
54.5
4.95
606
22.0
210
190
260
0.0193
2.68
44
43
710
132S
82.0
81.5
79.0
65.0
56.0
43.0
5.84
514
29.6
250
230
280
0.0385
5.29
49
65
2875
100L**
88.5
88.5
87.0
87.5
83.0
73.0
5.36
932
9.97
400
320
370
0.0063
0.280
57
38
43
1430
100L
87.5
87.5
87.0
82.5
77.0
65.0
5.95
748
20.0
290
270
310
0.0125
1.34
46
965
132S**
88.5
87.5
86.0
81.0
75.0
63.0
5.79
777
29.7
200
170
290
0.0385
3.50
51
71
710
132M
83.5
83.5
81.0
65.0
55.0
42.0
7.65
523
40.4
250
235
290
0.0480
6.97
50
75
2880
112M **
89.5
90.0
89.0
91.0
88.5
81.0
7.01
856
13.3
280
240
350
0.0115
0.383
57
48
1445
112M
89.0
89.0
88.0
84.0
80.0
68.5
7.64
785
26.4
240
180
300
0.0208
1.81
48
48
970
132M **
89.5
89.0
87.0
79.0
72.5
60.0
8.07
743
39.4
210
180
310
0.0515
4.75
51
87
720
160M
84.5
84.0
81.5
73.0
65.0
52.5
9.25
541
53.1
200
180
250
0.0878
9.51
51
118
2915
132S**
91.5
91.5
90.5
88.0
85.0
78.5
9.67
776
18.0
220
190
280
0.0190
0.505
64
71
1460
132S
90.5
90.5
89.0
82.5
76.0
63.5
10.40
817
36.0
270
220
320
0.0333
2.37
53
72
960
132M
89.0
88.5
88.0
82.0
77.0
66.0
10.70
654
54.7
190
170
270
0.0543
6.33
47
90
715
160M
85.0
85.5
83.5
73.0
65.0
52.0
12.50
520
73.5
170
160
230
0.123
12.7
54
118
2895
132S**
91.0
91.0
90.0
80.0
74.0
63.0
14.30
629
24.7
210
180
260
0.0190
0.670
64
84
1455
132M
91.0
91.0
90.0
85.0
80.0
68.5
13.40
821
49.2
270
220
320
0.0358
3.10
56
82
970
160M **
91.0
91.0
90.0
81.0
75.0
64.0
14.10
674
73.8
240
200
260
0.121
8.34
55
138
720
160L
87.0
87.0
85.0
72.0
64.0
51.0
16.60
572
99.5
195
185
270
0.147
16.6
55
155
All figures are based on tests carried out on 415 Volt3-Phase Motors.
Test Method: AS1359.5, Method B.
Tolerance: refer page 30
** motors comply to MEPS 2006 High Efficiency requirements.
dB(A): Mean Sound Pressure Level on no load at 1 metre.
Motor data 8 pole and slower speeds not listed available on request.
Data subject to change without notice.
RETURN TO INDEX
15
18.5
22
30
37
45
55
75
90
110
132
150
185
Notes:
1.
2.
3.
4.
Efficiency
Power Factor
Full
Load
(%)
3/4
Load
(%)
1/2
Load
(%)
Full
Load
(%)
3/4
Load
(%)
1/2
Load
(%)
Current
Torque
Inertia
Noise Weight
Full Locked Full Locked Pull Break- Rotor MaxLoad Level Foot
Load Rotor Load Rotor Up
Down J=GD2/4 J=GD2/4 dB(A) Mount
(A)
(%)
N-m %FLT %FLT %FLT Kg-m2 Kg-m2
Kgs
2935
160M **
92.5
92.5
92.0
91.5
89.0
84.5
18.40
761
35.8
230
200
280
0.0458
0.973
70
128
1460
160M **
92.5
92.5
92.0
85.0
82.0
74.0
19.80
707
72.0
230
180
270
0.0918
4.57
56
133
159
975
160L
91.0
90.5
89.0
79.0
72.5
60.0
21.7
737
108
280
230
280
0.158
12.2
52
720
180L
87.5
88.0
87.5
78.5
74.0
72.5
22.7
529
146
180
160
215
0.314
24.3
56
210
2935
160M **
92.5
92.0
91.5
91.0
88.0
81.0
24.70
789
48.8
240
210
290
0.0458
1.28
70
130
1460
160L**
93.0
93.0
92.5
88.0
84.5
76.5
25.40
728
98.1
230
180
270
0.116
6.02
56
153
970
180LC **
92.0
92.0
92.0
84.0
79.5
71.5
26.90
613
148
230
190
250
0.336
15.9
58
215
720
200LC
89.0
89.5
89.5
81.5
78.5
70.5
28.6
454
199
150
130
180
0.445
31.8
57
282
2925
160L**
93.0
93.0
93.0
91.5
89.5
84.0
30.50
803
60.4
260
210
300
0.0593
1.55
72
148
1470
180MC **
94.0
94.0
93.5
85.0
81.0
72.5
32.50
754
120
240
180
270
0.177
7.42
63
194
975
200LC **
93.0
93.5
93.0
78.0
74.0
64.0
35.80
615
181
230
200
250
0.459
19.7
55
285
334
725
225S
90.0
90.5
90.0
77.0
72.0
61.0
37.4
508
244
190
180
160
0.591
39.2
58
2935
180MA**
93.5
93.5
92.5
87.5
84.5
76.0
38.1
787
71.6
250
210
300
0.0708
1.89
72
194
1465
180LC **
94.0
94.0
93.5
86.0
82.5
74.0
38.5
701
143
230
180
270
0.198
8.76
64
215
300
975
200LC **
93.5
93.5
93.5
79.0
75.0
67.0
42.2
592
216
220
190
220
0.521
23.4
54
735
225MC **
92.5
92.5
92.0
78.0
73.5
63.0
43.2
509
286
190
170
195
0.709
46.8
58
375
2955
200LA**
94.0
94.0
93.0
89.0
87.5
83.5
49.6
685
97.0
175
150
260
0.151
2.43
76
286
300
1470
200LC **
94.5
94.5
94.5
87.0
85.5
78.0
50.5
773
195
230
190
270
0.364
11.5
64
980
225MC **
94.0
94.0
93.5
85.5
82.0
75.0
51.7
590
292
210
190
230
0.756
30.5
61
390
735
250SC
92.5
92.5
92.0
76.5
71.0
61.0
58.7
545
390
205
180
225
1.025
61.2
65
480
2950
200LA**
94.5
94.5
93.5
90.0
88.0
84.5
61.0
656
120
155
135
260
0.189
2.98
76
312
1475
225SC **
95.0
95.0
94.5
85.0
81.0
73.0
64.3
669
240
200
180
240
0.474
14.1
69
359
985
250SC **
94.0
94.5
94.0
86.5
83.5
76.0
63.8
634
359
210
200
250
1.049
37.8
64
480
735
250MC
93.0
93.0
92.0
78.0
74.0
63.0
71.5
559
481
210
180
235
1.225
75.5
68
554
2955
225MA
94.5
94.5
93.5
92.0
91.0
88.0
72.0
667
145
140
130
230
0.311
3.53
78
373
1475
225MC **
95.0
95.0
94.5
85.0
81.0
72.5
77.1
642
291
200
175
250
0.495
16.7
69
387
554
985
250MC **
94.5
95.0
94.5
87.5
85.0
77.5
75.3
704
436
230
200
250
1.277
44.8
66
2960
250SA**
95.0
94.5
94.0
89.5
88.0
87.0
91.5
705
177
150
130
250
0.387
4.32
78
470
1480
250SC **
95.5
95.0
94.5
87.0
84.0
77.0
93.7
700
355
230
200
260
0.978
20.3
71
528
984
280SC **
95.0
94.5
94.0
85.0
82.5
75.0
94.8
680
534
165
140
230
2.125
55.0
77
650
2960
250MA**
95.5
95.5
95.0
91.0
88.0
85.0
119.0
693
242
140
130
250
0.454
5.60
78
548
1480
250MC **
95.5
95.5
95.0
87.0
84.0
77.0
125.0
648
484
220
180
240
1.123
26.8
72
574
984
280MC **
95.3
94.9
94.8
86.0
83.3
76.0
127
689
728
160
136
230
2.775
46.8
77
730
2960
280SA
95.4
94.8
94.0
89.0
87.5
82.0
147
717
290
130
110
230
0.725
6.88
83
650
1480
280SC
95.6
95.0
94.2
87.0
84.2
78.0
150
703
581
160
136
230
2.025
33.0
80
700
985
315SC
95.3
94.8
94.3
86.0
83.3
76.0
153
690
873
155
131
230
4.275
88.2
77
920
2960
280MA
95.4
94.8
94.0
89.7
88.0
82.0
179
721
355
120
102
230
0.850
8.08
83
700
1482
280MC
95.8
95.2
94.4
88.0
84.5
78.5
182
709
709
155
131
230
2.375
39.0
80
850
985
315MC **
95.8
95.3
94.8
86.2
84.0
76.5
185
697
1067
150
127
220
4.975
105
77
1010
2976
315SA
95.8
95.2
94.3
90.0
88.0
83.0
213
723
424
115
98
220
1.625
9.13
83
840
1482
315SC **
96.2
95.6
94.8
88.5
85.0
79.5
216
713
851
150
127
220
2.800
44.0
80
940
986
315MC
95.8
95.3
94.8
86.2
84.5
77.5
222
694
1279
150
127
220
5.050
120
77
1050
2976
315MA
96.0
95.4
94.5
90.3
89.0
83.5
241
726
481
110
94
220
1.625
10.5
83
920
1485
315MC
96.2
95.6
94.8
88.5
85.0
80.0
245
714
965
150
127
220
3.650
50.5
80
930
2982
315MA
96.0
95.4
94.5
90.3
89.2
83.5
297
724
593
105
91
220
1.975
12.8
83
1000
1486
315MB
96.2
95.6
94.8
89.0
85.6
80.5
301
714
1189
140
119
220
3.825
61.8
80
1100
All figures are based on tests carried out on 415 Volt3-Phase Motors.
Test Method: AS1359.5, Method B.
Tolerance: refer page 30
** motors comply to MEPS 2006 High Efficiency requirements.
nine
RETURN TO INDEX
Fig. 1
Output (kW)
2P
4P
6P
8P
Frame
Size
0.18
0.18
0.37 / 0.55
0.37
0.18
0.75 / 1.1
0.55 / 0.75
0.37 / 0.55
Fig.
No.
Dimensions (mm)
A
AA
AB
AC
AD
AE
BB
HA
HC
63
100
28
120
144
138
100
80
100
40
63
135
71
112
35.5
140
162
148
110
90
115
45
71
152
0.18
80
125
35.5
155
177
179
130
100
130
50
80
168
HD
1.5
1.1
0.75
0.37
90S
140
35.5
170
200
192
143
100
130
56
90
10
190
2.2
1.5
1.1
0.55
90L
140
35.5
170
200
192
143
125
150
56
90
10
190
2.2 / 3
1.5
0.75 / 1.1
100L
160
45
195
219
202
153
140
175
63
100
12.5
243
265
2.2
1.5
112M
190
45
224
238
211
162
140
175
70
112
14
5.5 / 7.5
5.5
2.2
132S
216
45
250
273
249
187
140
175
89
132
16
310
7.5
4 / 5.5
132M
216
45
250
273
249
187
178
212
89
132
16
310
Shaft Extension
Bearings
Frame
Size
HE
KK
LE
ED
GA
DH
DE
NDE
63
10
M20 P1.5
219
76
11
23
18
8.5
12.5
M4 8
6201ZZ
6201ZZ
71
35
M20 P1.5
250.5
85.5
14
30
24
11
16
M5 10
6202ZZ
6202ZZ
80
13
10
M25 P1.5
282.5
92.5
19
40
25
15.5
21.5
M6 12
6204ZZ
6204ZZ
90S
23
10
M25 P1.5
307.5
101.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
90L
23
10
M25 P1.5
332.5
101.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
100L
33
12
M25 P1.5
374.5
111.5
28
60
40
24
31
M10 20
6206ZZ
6305ZZ
112M
45
12
M25 P1.5
391.5
121.5
28
60
40
24
31
M10 20
6306ZZ
6306ZZ
132S
58
12
M40 P1.5
454
145
38
80
56
10
33
41
M12 24
6308ZZ
6306ZZ
132M
58
12
M40 P1.5
492
145
38
80
56
10
33
41
M12 24
6308ZZ
6306ZZ
Notes:
10
Fig. 2
ten
RETURN TO INDEX
Fig. 4
Fig. 3
Output (kW)
2P
4P
6P
8P
Frame
Size
11 / 15
11
7.5
4 / 5.5
160M
18.5
15
11
7.5
160L
22
180MA
18.5
180MC
22
15
11
180LC
Fig.
No.
3
4
3
Dimensions (mm)
A
AA
AB
AC
AD
AE
BB
HA
HD
254
50
300
334
287
225
210
250
108
160
18
377
254
50
300
334
287
225
254
300
108
160
18
377
279
75
355
382
312
250
241
297
121
180
20
421
279
75
355
382
312
250
241
297
121
180
20
421
279
75
355
382
312
250
279
335
121
180
20
421
30 / 37
200LA
318
80
400
420
374
287
305
365
133
200
25
469
30
18.5 / 22
15
200LC
318
80
400
420
374
287
305
365
133
200
25
469
37
18.5
225SC
356
90
450
458
427
330
286
350
149
225
30
524
45
225MA
356
90
450
458
427
330
311
375
149
225
30
524
356
90
450
458
427
330
311
375
149
225
30
524
406
100
500
510
493
375
311
385
168
250
36
575
45
30
22
225MC
55
250SA
55
37
30
250SC
406
100
500
510
493
375
311
385
168
250
36
575
75
250MA
406
100
500
510
493
375
349
425
168
250
36
575
75
45
37
250MC
406
100
500
510
493
375
349
425
168
250
36
575
Shaft Extension
Bearings
Frame
Size
HE
KK
LE
ED
GA
DH
DE
NDE
160M
83
14.5
M40 P1.5
608
180
42
110
80
12
37
45
M16 32
6309ZZ
6307ZZ
160L
83
14.5
M40 P1.5
652
180
42
110
80
12
37
45
M16 32
6309ZZ
6307ZZ
180MA
103
14.5
M40 P1.5
672
200
48
110
80
14
42.5
51.5
M16 32
(6211C3)
(6211C3)
180MC
103
14.5
M40 P1.5
672
200
48
110
80
14
42.5
51.5
M16 32
6311ZZ
6310ZZ
180LC
103
14.5
M40 P1.5
710
200
48
110
80
14
42.5
51.5
M16 32
6311ZZ
6310ZZ
200LA
88
18.5
M50 P1.5
770
222
55
110
80
16
49
59
M20 40
(6312C3)
(6212C3)
200LC
88
18.5
M50 P1.5
770
222
55
110
80
16
49
59
M20 40
6312
6212
225SC
57
18.5
M50 P1.5
816
241
60
140
110
18
53
64
M20 40
6313
6213
(6212C3)
225MA
57
18.5
M50 P1.5
811
241
55
110
80
16
49
59
M20 40
(6312C3)
225MC
57
18.5
M50 P1.5
841
241
60
140
110
18
53
64
M20 40
6313
6213
250SA
42
24
M63 P1.5
882.5
263.5
60
140
110
18
53
64
M20 40
(6313C3)
(6213C3)
250SC
42
24
M63 P1.5
882.5
263.5
70
140
110
20
62.5
74.5
M20 40
NU316
6313
250MA
42
24
M63 P1.5
920.5
263.5
60
140
110
18
53
64
M20 40
(6313C3)
(6213C3)
250MC
42
24
M63 P1.5
920.5
263.5
70
140
110
20
62.5
74.5
M20 40
NU316
6313
eleven
11
RETURN TO INDEX
Output (kW)
2P
4P
6P
8P
AA
AB
AC
AD
AE
AF
BA
BB
HA
90
280SA
457
110
560
603
600
445
293
368
110
445
190
280
30
90
55
45
280SC
457
110
560
603
600
445
293
368
110
445
190
280
30
110
280MA
457
110
560
603
600
445
293
419
130
495
190
280
30
110
75
55
280MC
457
110
560
603
600
445
293
419
130
495
190
280
30
132
315SA
508
115
615
642
620
465
312
406
115
490
216
315
35
132
90
75
315SC
508
115
615
642
620
465
312
406
115
490
216
315
35
150 / 185
315MA
508
115
615
642
620
465
312
457
115
540
216
315
35
150
110 / 132
90
315MC
508
115
615
642
620
465
312
457
115
540
216
315
35
185
315MB
508
115
615
642
620
465
312
457
115
540
216
315
35
185
315MC**
508
115
615
642
703
482
312
457
115
540
216
315
35
Shaft Extension
HD
HE
KK
LE
ED
EE
GA
DH
DE
NDE
280SA
651
82
24
M63x1.5
1042
344
65
140
110
134
18
58
69
M20x30
6314C3
6314C3
280SC
651
82
24
M63x1.5
1072
344
80
170
140
157
22
71
85
M20x30
NU318
6316
280MA
651
82
24
M63x1.5
1092
343
65
140
110
134
18
58
69
M20x30
6314C3
6314C3
280MC
651
82
24
M63x1.5
1122
343
80
170
140
157
22
71
85
M20x30
NU318
6316
315SA
723
112
28
M63x1.5
1131
369
65
140
110
134
18
58
69
M20x30
6314C3
6314C3
315SC
723
112
28
M63x1.5
1161
369
85
170
140
157
22
76
90
M20x30
NU320
6316
315MA
723
112
28
M63x1.5
1182
369
65
140
110
134
18
58
69
M20x30
6314C3
6314C3
315MC
723
112
28
M63x1.5
1212
369
85
170
140
157
22
76
90
M20x30
NU320
6316
315MB
723
112
28
M63x1.5
1212
369
85
170
140
157
22
76
90
M20x30
NU320
6316
315MC**
723
112
28
BLANK
1212
369
95
170
140
157
25
86
100
M24x48
NU320
6316
MAX-E2 Motor
Frame sizes D280-315m
12
Bearings
Frame
Size
Notes:
Dimensions (mm)
Frame
Size
twelve
RETURN TO INDEX
Fig. 1
Fig. 2
Output (kW)
2P
4P
6P
8P
Frame
Size
0.18
0.18
63
0.37 / 0.55
0.37
0.18
71
0.75 / 1.1
0.55 / 0.75
0.37 / 0.55
0.18
80
1.5
1.1
0.75
0.37
90S
2.2
1.5
1.1
0.55
90L
2.2 / 3
1.5
0.75 / 1.1
100L
2.2
1.5
112M
5.5 / 7.5
5.5
2.2
132S
7.5
4 / 5.5
132M
Fig.
No.
1
2
Flange
AC
AD
AE
HB
KK
LA
LB
LL
144
138
100
M20 P1.5
225
12
235
115
95
140
162
148
110
M20 P1.5
278
12
248
17
130
110
160
177
179
130
M25 P1.5
280
12
240
15
165
130
200
200
192
143
M25 P1.5
347
12
297
15
165
130
200
200
192
143
M25 P1.5
372
12
322
15
165
130
200
219
202
153
140
M25 P1.5
375
16
315
15
215
180
250
238
211
162
150
M25 P1.5
431
16
371
15
215
180
250
273
249
187
169
M40 P1.5
454
20
374
13
265
230
300
273
249
187
169
M40 P1.5
484
20
404
13
265
230
300
Flange
Dimensions (mm)
Shaft Extension
Bearings
Frame
Size
ED
GA
DH
DE
NDE
63
10
11
23
18
8.5
12.5
M4 8
6201ZZ
6201ZZ
71
10
3.5
14
30
24
11
16
M5 10
6202ZZ
6202ZZ
80
12
3.5
19
40
25
15.5
21.5
M6 12
6204ZZ
6204ZZ
90S
12
3.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
90L
12
3.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
100L
14.5
28
60
40
24
31
M10 20
6206ZZ
6305ZZ
112M
14.5
28
60
40
24
31
M10 20
6306ZZ
6306ZZ
132S
14.5
38
80
56
10
33
41
M12 24
6308ZZ
6306ZZ
132M
14.5
38
80
56
10
33
41
M12 24
6308ZZ
6306ZZ
Notes:
thirteen
13
RETURN TO INDEX
Fig. 3
Fig. 4
Output (kW)
2P
4P
6P
8P
AC
AD
AE
HB
KK
LA
LD
LL
11
7.5
4 / 5.5
160M
334
287
225
217
M40 P1.5
608
20
126
10
300
250
350
18.5
15
11
7.5
160L
334
287
225
217
M40 P1.5
652
20
148
10
300
250
350
180MA
382
312
250
241
M40 P1.5
672
20
155
10
300
250
350
382
312
250
241
M40 P1.5
672
20
155
10
300
250
350
180LC
382
312
250
241
M40 P1.5
710
20
174
10
300
250
350
200LA
420
374
287
260
M50 P1.5
770
20
154
20
350
300
400
18.5
180MC
22
15
11
30 / 37
30
18.5 / 22
37
30
15
200LC
420
374
287
260
M50 P1.5
770
20
154
20
350
300
400
225SC
458
427
330
286
M50 P1.5
816
22
94
30
400
350
450
225MA
458
427
330
286
M50 P1.5
811
22
107
30
400
350
450
225MC
458
427
330
286
M50 P1.5
841
22
107
30
400
350
450
510
493
375
312
M63 P1.5
882.5
22
86
30
500
450
550
22
55
250SA
55
37
30
75
75
45
18.5
45
45
Fig.
No.
Flange
11 / 15
22
37
250SC
510
493
375
312
M63 P1.5
882.5
22
86
30
500
450
550
250MA
510
493
375
312
M63 P1.5
920.5
22
105
30
500
450
550
250MC
510
493
375
312
M63 P1.5
920.5
22
105
30
500
450
550
Flange
Shaft Extension
Bearings
Frame
Size
ED
GA
DH
DE
NDE
160M
18.5
42
110
80
12
37
45
M16 32
6309ZZ
6307ZZ
6307ZZ
160L
18.5
42
110
80
12
37
45
M16 32
6309ZZ
180MA
18.5
48
110
80
14
42.5
51.5
M16 32
6211C3
6211C3
180MC
18.5
48
110
80
14
42.5
51.5
M16 32
6311ZZ
6310ZZ
180LC
18.5
48
110
80
14
42.5
51.5
M16 32
6311ZZ
6310ZZ
200LA
18.5
55
110
80
16
49
59
M20 40
6312C3
6212C3
200LC
18.5
55
110
80
16
49
59
M20 40
6312
6212
225SC
18.5
60
140
110
18
53
64
M20 40
6313
6213
6212C3
225MA
18.5
55
110
80
16
49
59
M20 40
6312C3
225MC
18.5
60
140
110
18
53
64
M20 40
6313
6213
250SA
18.5
60
140
110
18
53
64
M20 40
6313C3
6213C3
250SC
18.5
70
140
110
20
62.5
74.5
M20 40
NU316
6313
250MA
18.5
60
140
110
18
53
64
M20 40
6313C3
6213C3
250MC
18.5
70
140
110
20
62.5
74.5
M20 40
NU316
6313
Notes:
14
Dimensions (mm)
Frame
Size
fourteen
RETURN TO INDEX
Fig. 1
Output (kW)
2P
4P
6P
8P
Frame
Size
0.18
0.18
63
0.37 / 0.55
0.37
0.18
71
0.75 / 1.1
0.55 / 0.75
0.37 / 0.55
0.18
80
1.5
1.1
0.75
0.37
2.2
1.5
1.1
0.55
Fig.
No.
2
Fig. 2
Dimensions (mm)
A
AA
AB
AD
AE
BB
HA
HC
HD
HE
KK
100
28
120
123
97
80
100
69
63
135
10
M20 P1.5
112
35.5
140
148
110
90
115
72
71
152
35
M20 P1.5
125
35.5
155
179
130
100
130
50
80
180
13
10
M25 P1.5
90S
140
35.5
170
192
143
100
130
95
90
10
190
23
10
M25 P1.5
90L
140
35.5
170
192
143
125
150
95
90
10
190
23
10
M25 P1.5
2.2 / 3
1.5
0.75 / 1.1
100L
2.2
1.5
112M
5.5 / 7.5
5.5
2.2
132S
216
45
250
7.5
4 / 5.5
132M
216
45
250
11 / 15
11
7.5
4 / 5.5
160M
254
50
300
287
225
18.5
15
11
7.5
160L
254
50
300
287
225
22
180MA
279
75
355
312
250
18.5
180MC
279
75
355
312
22
15
11
180LC
279
75
355
30/37
200LA
318
80
30
18.5 / 22
15
200LC
318
80
Frame
Size
160
45
195
202
153
140
175
103
100
12.5
243
33
12
M25 P1.5
190
45
224
211
162
140
175
110
112
14
265
45
12
M25 P1.5
249
187
140
175
139
132
16
310
58
12
M40 P1.5
249
187
178
212
139
132
16
310
58
12
M40 P1.5
210
250
108
160
18
377
83
254
300
108
160
18
377
83
241
297
121
180
20
421
103
250
241
297
121
180
20
421
103
312
250
279
335
121
180
20
421
103
400
374
287
305
365
133
200
25
469
88
400
374
287
305
365
133
200
25
469
88
Flange
LA
LE
Fig. 3
Shaft Extension
Bearings
ED
GA
DH
DE
NDE
63
12
76
248
115
95
140
10
11
23
10
8.5
12.5
M4 8
6201ZZ
6201ZZ
71
12
86
278
130
110
160
10
3.5
14
30
14
11
16
M5 10
6202ZZ
6202ZZ
6204ZZ
80
12
92.5
282.5
165
130
200
12
3.5
19
40
25
15.5
21.5
M6 12
6204ZZ
90S
12
101.5
346.5
165
130
200
12
3.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
90L
12
101.5
371.5
165
130
200
12
3.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
100L
16
112
414.5
215
180
250
14.5
28
60
40
24
31
M10 20
6206ZZ
6305ZZ
112M
16
121.5
431.5
215
180
250
14.5
28
60
40
24
31
M10 20
6306ZZ
6306ZZ
132S
20
145
504
265
230
300
14.5
38
80
56
10
33
41
M12 24
6308ZZ
6306ZZ
132M
20
145
542
265
230
300
14.5
38
80
56
10
33
41
M12 24
6308ZZ
6306ZZ
160M
20
180
608
300
250
350
18.5
42
110
80
12
37
45
M16 32
6309ZZ
6307ZZ
160L
20
180
652
300
250
350
18.5
42
110
80
12
37
45
M16 32
6309ZZ
6307ZZ
180MA
20
200
672
300
250
350
18.5
48
110
80
14
42.5
51.5
M16 32
(6211C3)
(6211C3)
180MC
20
200
672
300
250
350
18.5
48
110
80
14
42.5
51.5
M16 32
6311ZZ
6310ZZ
180LC
20
200
710
300
250
350
18.5
48
110
80
14
42.5
51.5
M16 32
6311ZZ
6310ZZ
200LA
20
222
770
350
300
400
18.5
55
110
80
16
49
59
M20 40
(6312C3)
(6212C3)
200LC
20
222
770
350
300
400
18.5
55
160
80
16
49
59
M20 40
6312C3
6313C3
Notes:
fifteen
15
RETURN TO INDEX
Fig. 4
Output (kW)
Dimensions (mm)
2P
4P
6P
8P
Frame
Size
AA
AB
AD
AE
BA
BB
HA
HD
HE
37
18.5
225SC
356
90
450
427
330
286
350
149
225
30
524
57
Fig.
No.
KK
45
225MA
356
90
450
427
330
311
375
149
225
30
524
57
45
30
22
225MC
356
90
450
427
330
311
375
149
225
30
524
57
55
250SA
406
100
500
493
375
311
385
168
250
36
575
42
24
M63 P1.5
55
37
30
250SC
406
100
500
493
375
311
385
168
250
36
575
42
24
M63 P1.5
75
250MA
406
100
500
493
375
349
425
168
250
36
575
42
24
M63 P1.5
75
45
37
250MC
406
100
500
493
375
349
425
168
250
36
575
42
24
M63 P1.5
90
280SA
457
110
560
600
445
368
110
445
190
280
30
651
82
24
M63 P1.5
90
55
45
280SC
457
110
560
600
445
368
110
445
190
280
30
651
82
24
M63 P1.5
110
280MA
457
110
560
600
445
419
110
495
190
280
30
651
82
24
M63 P1.5
457
110
560
600
445
419
110
495
190
280
30
651
82
24
M63 P1.5
508
115
615
600
465
406
115
490
216
315
35
723
112
28
M63 P1.5
110
75
55
280MC
132
315SA
132
90
75
315SC
508
115
615
600
465
406
115
490
216
315
35
723
112
28
M63 P1.5
150 / 185
315MA
508
115
615
600
465
457
115
540
216
315
35
723
112
28
M63 P1.5
150
110 / 132
90
315MC
508
115
615
600
465
457
115
540
216
315
35
723
112
28
M63 P1.5
185
315MB
508
115
615
600
465
457
115
540
216
315
35
723
112
28
M63 P1.5
Flange
Shaft Extension
Bearings
Frame
Size
LA
LE
ED
EE
GA
DH
DE
225SC
22
241
816
400
350
450
18.5
60
140
110
18
53
64
M20 40
6313
6213
225MA
22
241
811
400
350
450
18.5
55
110
80
16
49
59
M20 40
6312C3
6212C3
225MC
22
241
841
400
350
450
18.5
60
140
110
18
53
64
M20 40
6313
6213
250SA
22
263.5
882.5
500
450
550
18.5
60
140
110
18
53
64
M20 40
6313C3
6213C3
NDE
250SC
22
263.5
882.5
500
450
550
18.5
70
140
110
20
62.5
74.5
M20 40
NU316
6313
250MA
22
263.5
920.5
500
450
550
18.5
60
140
110
18
53
64
M20 40
6313C3
6213C3
250MC
22
263.5
920.5
500
450
550
18.5
70
140
110
20
62.5
74.5
M20 40
NU316
6313
280SA
22
344
1042
500
450
550
18.5
65
140
110
134
18
58
69
M20 40
6314C3
6314C3
280SC
22
344
1072
500
450
550
18.5
80
170
140
157
22
71
85
M20 40
NU318
6316
6314C3
280MA
22
344
1092
500
450
550
18.5
65
140
110
134
18
58
69
M20 40
6314C3
280MC
22
344
1122
500
450
550
18.5
80
170
140
157
22
71
85
M20 40
NU318
6316
315SA
25
369
1131
600
550
660
24
65
140
110
134
18
58
69
M20 40
6314C3
6314C3
315SC
25
369
1161
600
550
660
24
85
170
140
157
22
76
90
M20 40
NU320
6316
315MA
25
369
1182
600
550
660
24
65
140
110
134
18
58
69
M20 40
6314C3
6314C3
315MC
25
369
1212
600
550
660
24
85
170
140
157
22
76
90
M20 40
NU320
6316
315MB
25
369
1212
600
550
660
24
85
140
140
157
22
76
90
M20 40
NU320
6316
Notes:
16
Fig. 5
sixteen
RETURN TO INDEX
Fig. 1
Output (kW)
2P
4P
6P
8P
Frame
Size
0.18
0.18
63
Fig.
No.
Dimensions (mm)
A
AA
AB
AC
AD
AE
BB
HA
HC
HD
HE
KK
100
28
120
144
123
97
80
100
40
63
135
10
M20 P1.5
M20 P1.5
0.37 / 0.55
0.37
0.18
71
162
133
107
90
115
45
71
152
35
0.75 / 1.1
0.55 / 0.75
0.37 / 0.55
0.18
80
177
179
130
100
130
50
80
168
13
10 M25 P1.5
200
192
143
100
130
56
90
10
190
23
10 M25 P1.5
200
192
143
125
150
56
90
10
190
23
10 M25 P1.5
12 M25 P1.5
1.5
1.1
0.75
0.37
90S
2.2
1.5
1.1
0.55
90L
2.2 / 3
1.5
0.75 / 1.1
100L
160
45
195
219
202
153
140
175
63
100 12.5
243
33
2.2
1.5
112M
190
45
224
238
211
162
140
175
70
112
14
265
45
12 M25 P1.5
5.5 / 7.5
5.5
2.2
132S
216
45
250
273
249
187
140
175
89
132
16
310
58
12 M40 P1.5
7.5
4 / 5.5
132M
216
45
250
273
249
187
178
212
89
132
16
310
58
12 M40 P1.5
Flange
Shaft Extension
Bearings
Frame
Size
LE
ED
GA
DH
DE
NDE
63
105
248
75
60
90
M5
11
23
18
8.5
12.5
M4 8
6201ZZ
6201ZZ
71
112
277
85
70
105
M6
3.5
14
30
24
11
16
M5 10
6202ZZ
6202ZZ
80
92
282
100
80
120
M6
3.5
19
40
25
15.5
21.5
M6 12
6204ZZ
6204ZZ
90S
140
346
115
95
140
M8
3.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
90L
140
371
115
95
140
M8
3.5
24
50
32
20
27
M8 16
6205ZZ
6205ZZ
100L
111
374
130
110
160
M8
28
60
40
24
31
M10 20
6206ZZ
6305ZZ
112M
161
431
130
110
160
M8
28
60
40
24
31
M10 20
6306ZZ
6306ZZ
132S
145
454
165
130
200
M10
38
80
64
10
33
41
M12 24
6308ZZ
6306ZZ
132M
145
492
165
130
200
M10
38
80
64
10
33
41
M12 24
6308ZZ
6306ZZ
Notes:
seventeen
17
RETURN TO INDEX
Notes:
Radial Load
Horizontal
Shaft
twenty
Axial Load
Shaft Down
(down thrust)
Axial Load
Shaft Down
(up thrust)
80
47 kg
69 kg
65 kg
73 kg
90
49 kg
73 kg
66.5 kg
79.5 kg
100
72 kg
105 kg
95 kg
115 kg
112
95 kg
138 kg
124 kg
152 kg
132
147 kg
143 kg
123 kg
163 kg
160
179 kg
174 kg
134 kg
214 kg
292 kg
180
248 kg
238 kg
182 kg
200
297 kg
290 kg
210 kg
370 kg
225
305 kg
310 kg
230 kg
390 kg
510 kg
250
1400 kg
325 kg
320 kg
280
1500 kg
315M
1650 kg
18
Axial Load
Horizontal
Shaft
RETURN TO INDEX
Cooling
Designation System Concerning Methods of Cooling Refers to Standard AS1359.106.
Standard Code Example
Code
Description
IC 01
IC411
Enclosed machine.
Smooth or finned ventilated casing.
External shaft-mounted fan.
IC416
Enclosed machine.
Smooth or finned ventilated casing.
External motorized axial fan
supplied with machine.
Type
Example
Code
IC
(A)
(A)
International Cooling
Circuit Arrangement
Primary Coolant
Method of Movement
of Primary Coolant
0 : Free convection
1 : Self-circulation
6 : Machine-mounted independent component
Secondary Coolant
Method of Movement
of Secondary Coolant
0 : Free convection
1 : Self-circulation
6 : Machine-mounted independent component
Cooling air flows from the non-drive-end to the drive end. When the motor is installed care should be
taken not to impede the airflow into the motor fan cover. As a guide the following minimum dimension BL
should be adopted.
Motor
Frame
Dimensions
BL (mm)
80 - 100
60
112 - 132
85
160 - 180
85
200 - 250
110
280
140
315 - 355
180
twenty one
19
RETURN TO INDEX
Notes:
Motor Watts
Amps
D80
17
0.1
D90
29
0.12
95
D100
29
0.12
90
105
D112
46
0.22
D132
46
0.22
85
D160
75
0.42
140
D180
75
0.42
135
D200
135
0.59
95
20
twenty two
RETURN TO INDEX
Flange Mounted
Horizontal Shaft.
Foot mounted.
Horizontal Shaft.
D type flange at
D.E. No feet.
Horizontal Shaft.
D type flange at
D.E. Foot mounted.
Horizontal Shaft.
Foot wall mounted with
feet on left-side when
viewed from D.E.
Vertical Shaft.
D type flange at D.E.
Shaft down. No feet.
Vertical Shaft.
D type flange at
D.E. Wall mounted.
Shaft down.
Horizontal Shaft.
Foot wall mounted
with feet on right-side
when viewed from D.E.
Vertical Shaft.
D type flange at D.E.
Shaft up. No feet.
Vertical Shaft.
D type flange at
D.E. Wall mounted.
Shaft up.
Horizontal Shaft.
Ceiling mounted with
feet above motor.
Horizontal Shaft.
C type flange at
D.E. No feet.
Horizontal Shaft.
C type flange at
D.E. Foot mounted.
IM 2111
Vertical Shaft.
Wall mounted.
Shaft down.
Vertical Shaft.
C type flange at D.E.
Shaft down. No feet.
Vertical Shaft.
C type flange at
D.E. Wall mounted.
Shaft down.
IM 2131
Vertical Shaft.
Wall mounted.
Shaft up.
Vertical Shaft.
C type flange at D.E.
Shaft up. No feet.
Vertical Shaft.
C type flange at
D.E. Wall mounted.
Shaft up.
It is important to nominate the IM code at enquiry and order stage to ensure that drain holes are in the correct position
and bearing arrangement is checked for suitability if the IM code differs from standard.
IM Code
(IM Code)
Foot
IM1001
IMB3
Right
From below
Flange
IM3011
IMV1
IM2001
IMB35
Right
From below
SLIDE
RAIL
FRAME
SIZE
AL
AT
AU
AX
AY
AZ
BT
min.
XA
max.
XB
XD
XE
XF
M0809
80
90
100
112
132
160
180
200
225
250
280
315
355
355
470
470
470
615
615
780
780
965
965
1215
12
12
16
16
16
19
19
25
25
30
30
40
10
10
12
12
12
15
15
19
19
24
24
38
30
30
44
44
44
64
64
82
82
100
100
125
105
105
170
170
170
170
170
210
210
275
275
380
35
35
52
52
52
76
76
100
100
100
100
123
95
80
160
125
100
155
125
190
140
250
190
330
45
45
50
50
50
67
67
80
80
86
86
110
30
30
43
43
43
57
57
82
82
82
82
95
6
6
6
6
6
11
11
12
12
16
16
20
325
325
430
430
430
565
565
725
725
885
885
1115
15
15
18
18
18
25
25
27
27
40
40
50
M1013
M1618
M2022
M2528
M3100
twenty three
21
RETURN TO INDEX
22
twenty four
Tests
Definition
IP
No protection.
No protection.
Protected against
solid objects of
over 50mm
(e.g. accidental
hand contact).
Protected against
vertically dripping
water (condensation).
Protected against
solid objects of
over 12mm
(e.g. finger).
Protected against
water dripping up to
15 from the vertical.
Protected against
solid objects of
over 2.5mm
(e.g. tools, wire).
Protected against
solid objects of
over 1mm
(e.g. thin wire).
Protected against
water splashes from
all directions.
Protected against
dust (e.g. no deposits
of harmful material).
Protected against
jets of water from
all directions.
Totally protected
against dust.
Protected against
jets of water
comparable to
heavy seas.
Protected against
effects of immersion
to depths of between
0.15 and 1m.
Protected against
the effects of prolonged
immersion at depth.
Tests
Definition
RETURN TO INDEX
Notes:
Temperature
Factor
Altitude
above sea level
Altitude
Factor
30C
1.06
1000 m
35C
1.03
1500 m
0.97
0.945
40C
2000 m
45C
0.97
2500 m
0.92
50C
0.93
3000 m
0.89
55C
0.9
3500 m
0.865
60C
0.865
4000 m
0.835
Earth Topography
twenty five
23
RETURN TO INDEX
Power in
Watts
80 ~ 100
25
112
21
132 ~ 160
40
180 ~ 200
26
225 ~ 250
42
280
54
315M
99
315A
200
355
250
Connection Diagrams
TECO motors are connected as shown on the
motor nameplate, typical Star or Delta connection
diagram is shown below.
TECO stock motors 4 kW and below are
380 ~ 415 Volt 50 Hz STAR connected and may
Duty
TECO motors are supplied suitable for S1
operation (continuous operation under rated load).
When the motor is to operate under any other type
of duty the following information should be supplied
to determine the correct motor size.
24
twenty six
RETURN TO INDEX
Conversions
Output Power
P (kW) = M x n
9550
Length
Output Power
Pmec = 3 x U x I x cos x
1000
Output Torque
M = 9550 x P
n
Efficiency
= Output kW
Input kW
= Pmec x 1000
3 x U x I x cos
I = Pelec x 1000
3 x U x cos
I - Motor current, can be calculated for full or partial
loadings.
Use Efficiency and Power Factor relative to motor
loadings.
Motor Speed
n = 120 x f
Poles
100
0.1
1 ft =
0.3048
30.48
304.8
1 in =
0.254
2.54
25.4
kp
0.102
102
1 kp =
9.807
1000
1 lbf =
4.448
0.4536
453.6
1 in =
0.254
2.54
25.4
km/h
m/min
m/s
1 km/h =
16.667
0.2778
1 m/min =
0.06
16.7 x 10 -
Velocity
1m/s =
3.6
60
1 in =
0.254
2.54
25.4
Nm
kgfm
1 Nm =
0.10197
1 kgfm =
9.8067
1 lbf.ft =
1.356
0.1383
1 lbf.in =
0.1129
11.5 x 10 -
Power
kW
hp
1 kW =
1.341
1 hp =
0.7457
Moment of inertia
kgm (J)
kgfm(GD)
1 kgm (J) =
1 kgfm(GD) =
0.25
10
12
50
3000
1500
1000
750
600
500
60
3600
1800
1200
900
720
600
Subscript
Pel = electrical
P mec = mechanical
1
0.001
Torque
Motor Current
I = Pmec x 1000
3 x U x cos x
P = Power in kW
1000
1m=
1 mm =
1N=
mm
Key:
cm
Hz
m = Torque in Nm
n = Rotational speed in r/min
U = Line voltage in V
I = Line current in A
cos = Power factor (per unit)
= Motor efficiency (per unit)
f = Frequency in Hz
J = WR 2 = WK 2
twenty seven
25
RETURN TO INDEX
Insulation Classes
The majority of TECO motors comply with a
limitation of Class E temperature rise (75C) or
less thereby providing a minimum of an additional
5C that can be added to the safety margin, which
provides the client with a motor that will perform
extremely well in arduous temperature applications
180
whether this be load or ambient induced.
160
180
140
160
Temperature
140
Temperature
120
100
80
120
100
80
60
40
60
20
40
20
0
B
H
Insulation Class
Insulation Class
The graph below indicates the typical speed vs. torque current characteristics of a D132 frame motor to
Design N Normal Torque. The motor is started DOL and the major points on these curves are defined below.
Speed
SpeedvsvsTorque
Torque- -Current
CurrentCurves
Curves
400
400
Pull
Pullout
outor
or
Breakdown
Breakdowntorque
torque
LockedRotor
Rotoror
or
Locked
StartingCurrent
Current
Starting
300
300
% Full Load Torque
% Full Load Torque
StartingTorque
Torque
Starting
800
Pull out or
Breakdown torque
Locked Rotor or
Starting Current
200
200
600
Locked Rotor or
Starting Torque
Pull-up
Pull-upTorque
Torque
100
100
200
400
00
100
00
20
20
40
40
60
60
Full Load Torque
200
twenty eight
20
40
60
% Synchronous Speed
80
80
80
00
100
100
%%Full
FullLoad
LoadTorque
Torque
FullLoad
LoadCurrent
Current
%%Full
FullLoad
LoadCurrent
Current
Full
%%Synchronous
SynchronousSpeed
Speed
26
200
200
Full
FullLoad
LoadTorque
Torque
Pull-up Torque
300
400
400
600
600
Speed vs
TorqueRotor
-Rotor
Current
Locked
or Curves
Locked
or
400
800
800
0
100
RETURN TO INDEX
Pole
80 - 112
132 - 160
180 - 200
225 - 250
280
12
10
315M
3
22
20
16
10
28
25
20
12
GD Kg-m
0.75
0.325
0.081
1.41
0.353
3.65
0.913
7.54
1.1
0.440
0.110
2.09
0.523
5.60
1.40
11.0
2.74
0.145
2.68
0.670
7.30
1.83
14.6
3.65
WR Kg-m
2
GD Kg-m
2
2 Pole
4 Pole
6 Pole
8 Pole
1.89
1.5
0.580
2.2
0.850
0.213
4.14
1.04
10.7
2.68
21.2
5.29
1.12
0.280
5.35
1.34
14.0
3.50
27.9
6.97
1.53
0.383
7.23
1.81
19.0
4.75
38.0
9.51
5.5
2.02
0.505
9.49
2.37
25.3
6.33
50.6
12.7
7.5
2.68
0.670
12.4
3.10
33.3
8.34
66.4
16.6
11
3.89
0.973
18.3
4.57
48.7
12.2
97.3
24.3
15
5.11
1.28
24.1
6.02
63.8
15.9
127
31.8
18.5
6.20
1.55
29.7
7.42
78.8
19.7
157
39.2
22
7.54
1.89
35.1
8.76
93.5
23.4
187
46.8
30
9.73
2.43
46.0
11.5
122
30.5
245
61.2
37
11.9
2.98
56.5
14.1
151
37.8
302
75.5
45
14.1
3.53
66.9
16.7
179
44.8
358
89.5
55
17.3
4.32
82.2
20.6
220
55.0
441
110
75
22.4
5.60
107
26.8
187
46.8
577
144
90
27.5
6.88
132
33.0
353
88.2
710
178
110
32.3
8.08
156
39.0
418
105
132
36.5
9.13
176
44.0
481
120
150
41.8
10.5
202
50.5
185
51.1
12.8
247
61.8
Notes:
twenty nine
27
RETURN TO INDEX
Thermal Protection
The various types of thermal protection devices are described as below. Whilst these devices provide excellent
thermal protection they may not fully protect against some transient conditions.
Additional set(s) of these protection devices can be provided with a lower temperature rating which can be
utilized as an alarm function. Higher temperature ratings can be supplied for higher trip temperatures, however
care should be taken to ensure the temperature rating of the insulation class is not compromised.
Thermistors
Temperature vs. Resistance Diagram
Resistance ()
4000
1330
500
250
PTC element
20C
Temperature
TNF
TNF TNF TNF
-20C -5C
+5C
green
100
red
red
110
brown
brown
120
grey
grey
130
blue
blue
140
white
blue
150
black
black
160
blue
red
Thermistors and / or RTDs should not be Meggered or tested at a voltage above 2.5 volts.
28
thirty
TNF
+20C
RETURN TO INDEX
100.00
100.39
100.78
101.17
101.56
101.95
102.34
102.73
103.12
103.51
10
103.90
104.29
104.68
105.07
105.46
105.85
106.24
106.63
107.02
107.40
20
107.79
108.18
108.57
108.96
109.35
109.73
110.12
110.51
110.90
111.28
30
111.67
112.06
112.45
112.83
113.22
113.61
113.99
114.38
114.77
115.15
40
115.54
115.93
116.31
116.70
117.08
117.47
117.85
118.24
118.62
119.01
122.86
50
119.40
119.78
120.16
120.55
120.93
121.32
121.70
122.09
122.47
60
123.24
123.62
124.01
124.39
124.77
125.16
125.54
125.92
126.31
126.69
70
127.07
127.45
127.84
128.22
128.60
128.98
129.37
129.75
130.13
130.51
80
130.89
131.27
131.66
132.04
132.42
132.80
133.18
133.56
133.94
134.32
90
134.70
135.08
135.46
135.84
136.22
136.60
136.98
137.36
137.74
138.12
100
138.50
138.88
139.26
139.64
140.02
140.39
140.77
141.15
141.53
141.91
110
142.29
142.66
143.04
143.42
143.80
144.17
144.55
144.93
145.31
145.68
120
146.06
146.44
146.81
147.19
147.57
147.94
148.32
148.70
149.07
149.45
130
149.82
150.20
150.57
150.95
151.33
151.70
152.08
152.45
152.83
153.20
140
153.58
153.95
154.32
154.70
155.07
155.45
155.82
156.19
156.57
156.94
150
157.31
157.69
158.06
158.43
158.81
159.18
159.55
159.93
160.30
160.67
160
161.04
161.42
161.79
162.16
162.53
162.90
163.27
163.65
164.02
164.39
170
164.76
165.13
165.50
165.87
166.24
166.61
166.98
167.35
167.72
168.09
180
168.46
168.83
169.20
169.57
169.94
170.31
170.68
171.05
171.42
171.19
190
172.16
172.53
172.90
173.26
173.63
174.00
174.37
174.74
175.10
175.47
200
175.84
176.21
176.57
176.94
177.31
177.68
178.04
178.41
178.78
179.14
Type
Location
Alarm
Trip
RTD
Winding
140 o C
150 o C
RTD
90 o C
95 o C
thirty one
29
RETURN TO INDEX
Tolerance
Efficiency P <
= 150 kW
-15% (1- )
-10% (1- )
-1/6 (1-cos )
min. 0.02, max. 0.07
Slip P < 1 kW
Slip P >
= 1 kW
Starting torque
Starting current
Pull-up torque
Shaft Height
Dimension H
Frame Size
Tolerance
Tolerance (mm)
+0
63 to 250
- 0.5
+0
280 to 450
-1
Shaft
Dimension D.
D
14
19 to 28
32 to 48
30
thirty two
Tolerance
j6
j6
k6
55 to 80
m6
85 to 120
m6
125
m6
Tolerance
110
h7
h7
h7
300
h7
350
h7
450
h7
550
h7
Tolerance (mm)
+ 0.008
- 0.003
+ 0.009
- 0.004
+ 0.018
Tolerance (mm)
+0
- 0.035
+0
- 0.040
+0
- 0.046
+0
- 0.052
+0
- 0.057
+0
- 0.063
+0
- 0.070
+ 0.002
+ 0.030
+ 0.011
+ 0.035
+ 0.013
+ 0.040
+ 0.015
C Face
Dimension N
N
Tolerance
60 to 80
h7
95 & 110
h7
130
h7
Tolerance (mm)
+0
- 0.030
+0
- 0.035
+0
- 0.040
RETURN TO INDEX
100
90
% Motor Torque
80
70
Continuous operating region for standard motor
60
50
40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
110
120
Frequency Hz
Notes:
1. Installation: to follow the guidelines detailed in AS60034-17:2006 Cage induction motors when fed from converters - Application guide
2. Maximum safe operating speed to follow AS60034-1,Table 17
For variable torque loads (centrifugal pumps and fans) for speeds between 5-50 Hz derating is not normally
required. Outside of this range please check with TECO for motor suitability.
Typical variable and constant torque load curves are shown below.
Speed vs. Torque Curves (assuming load torque @ 100% speed = motor full load torque)
Speed vs. Torque
Curves
(assuming
load torque
@ 100%
= motor
full
load full load
Speed vs.
Torque
Curves (assuming
load
torquespeed
@ 100%
speed
= motor
400
400
200
300
300
Motor Speed
Torque
curve
Motor
Speed
Torque curve
under DOL conditions
under DOL conditions
100
200
Load curve Load curve
Constant torque
Constant torque
(conveyors etc)
(conveyors etc)
100
20
20
40
40
60
60
80
80
100
100
120
120
% Synchronous
Speed
% Synchronous
Speed
%Torque
Full Load Torque
% Full Load
thirty three
31
RETURN TO INDEX
continued
Note:
Frame Number
2 Pole
4 Pole
6 Pole
<
112
5200
3600
2400
132 ~ 180
4500
2700
2400
200
4500
2300
1800
225 ~ 315
3600
2300
1800
Motors are balanced to 60 Hz speed. If motor operation is above 60 Hz special balance may be required (please refer to TECO).
500 Volts
32
thirty four
RETURN TO INDEX
UN -5%
UN -
UN+5%
Torque curve
0.81
0.9
1.1
UN+10%
1.21
Slip
1.23
1.11
0.91
0.83
Rated current
1.1
1.05
0.98
0.98
Rated efficiency
0.97
0.98
0.98
1.03
1.02
0.97
0.94
Starting current
0.9
0.95
1.05
1.1
1.18
1.05
1.00
1.1
P (Watt) no-load
0.85
0.92
1.12
1.25
Q (reactive V A) no-load
0.81
0.9
1.1
1.21
Voltage
Frequency
Country
Voltage
Frequency
Country
Voltage
Frequency
Taiwan
380
60
Japan
200
50/60
* England
415*
50
60
* Germany
380*
50
Italy
380*
50
Spain
380*
50
Netherlands
380*
50
Australia
415
50
Singapore
400
50
Philippines
460
Malaysia
415
50
India
400
50
Indonesia
380
50
Korea
380
60
Thailand
380
50
Vietnam
380
50
China
380
50
USA
460
60
South Africa
380
50
Hong Kong
346
50
Canada
460 or 565
60
Saudi Arabia
380
50
Note:
thirty five
33
Melbourne
Brisbane
Perth
New Zealand
16 Longstaff Road,
50 Murdoch Circuit,
28 Belgravia Street,
Belmont WA 6104
Penrose, Auckland
Distributed by:
www.teco.com.au
TECOCI-032013