Max - E2: Low Voltage 3-Phase Induction Motors 0.18kW To 185kW

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36
At a glance
Powered by AI
The document provides information on TECO induction motors including their design, performance characteristics, standards, and dimensions.

The main components of an induction motor discussed are the stator, rotor, bearings, cooling system, terminal box and protection features.

The document discusses several factors that can affect induction motor performance including voltage, frequency, temperature, load, and speed.

Low Voltage 3-Phase Range

Induction Motors 0.18kW to 185kW

Totally Enclosed Fan-Cooled Cast Iron Frame Series

MAX - E2

Contents

page

PRODUCT DETAILS
General Information
Electrical Design and Standards

Altitude

Ambient

Direction of Rotation

Duty Rating

Electric Supply

Motor Types / MEPS

Performance

Standards

Stator and Windings

Testing

Variable Speed Drive Suitability

Winding Protection
Mechanical Design and Standards

Balance

Bearing and Lubrication System

Bearing Lubrication Instructions

Bearing False Brinelling Protection

Cooling System

Finish

Hardware

MAX-E3 H66

Mounting

Motor Construction

Protection

Rating Plate

Rotor Assembly

Terminal Box

Maximum Cable Sizes
Options
Performance Data MAX-E2 Range 63 ~ 315M
Outline Dimensions Frame 63 ~ 132 Foot Mount
Outline Dimensions Frame 160 ~ 250 Foot Mount
Outline Dimensions Frame 280 ~ 315M Foot Mount
Outline Dimensions Frame 63 ~ 132 Flange Mount
Outline Dimensions Frame 160 ~ 250 Flange Mount
Outline Dimensions Frame 63 ~ 200 Foot and Flange Mount
Outline Dimensions Frame 225 ~ 315M Foot and Flange Mount
Outline Dimensions Frame 63 ~ 132 Foot and C Face Mount

page
TECHNICAL DETAILS

2
2
2
2
2
2
2-3
3
3
3
3
3
3
4
4
5
5
6
6
6
6
6
6
6
6
7
7
7
7
8~9
10
11
12
13
14
15
16
17

Mechanical Design

Axial / Radial loadings

Cooling

Force Cooling IC416

Mounting (IM code)

Mounting - Cast Iron Slide Rails (dimensions)

Protection (IP code)
Electrical Design

Altitude and Ambient Temperature

Anti-condensation Heaters (optional)

Connection Diagrams

Duty

Formulae and Conversion

Insulation Classes

Speed vs. Torque Current

Starts per Hour

Maximum Load Inertia

Thermal Protection

Thermistors

Resistance Temperature Detectors

Tolerances for electromechanical characteristics

Variable Speed Drives (VVVF)

Voltage and Frequency during operation
Driving and Connecting Globally.

Motors
Motors

Drives

Drives
Controls

Controls
www.teco.com.au

18
19
20
21
21
22
23
24
24
24
25
26
26
27
27
28
28
29
30
31 ~ 32
33

RETURN TO INDEX

Welcome to

TECO Australia
Electric Motor Division

Teco!

along with the establishment of additional major


manufacturing facilities around the world to service
new markets and meet global demand.

Established in 1983 as a wholly owned subsidiary


of TECO Electric & Machinery Co., TECO Australia
has earned a reputation as a reliable supplier of
superior quality Electric Motors, Variable Speed
Drive systems and Motor Controls. These products
are all designed, manufactured and tested to meet
stringent Australian and International Standards.
TECO Electric Motors are regarded as one of
the leading brands available on the market and
are regularly specified and preferred amongst
equipment manufacturers, constructors, engineering companies and major end-users alike.

Today TECO designs and manufactures a complete


range of low, medium and high voltage motors,
Variable Speed Drives and Control Gear with sales
and support being offered on a global basis.

Quality Assurance
All TECO manufacturing plants and
TECO Australia have been assessed to
meet the requirements of ISO9001:2008

TECO Electric & Machinery Co.


From modest beginnings in 1956, TECO Electric
& Machinery Co. has grown to be one of the

documented quality systems.

ISO 9001
Lic QEC3088
SAI Global

Environmental and RoHS

worlds largest manufacturers of an extensive

TECO major manufacturing plants in Taiwan

range of electric motors. In addition to the core

have ISO14001 Environmental Management System

manufacturing facilities in Taiwan, the continual

accreditation.

growth of TECO on a global front has seen the

Low Voltage motors manufactured by TECO do not

formation in 1995 of the TECO Westinghouse

contain (or contain within the maximum allowable

Motor Company in the USA, borne out of the 100%

limits) any restricted hazardous substances as per

ownership of the Westinghouse Motor Company

European Directive 2002/95/EC(RoHS).

TECO AUSTRALIA PTY LTD

one

RETURN TO INDEX

Driving & Connecting Globally

General Information
The motors described in this catalogue are
designed and manufactured by TECO Electric &
Machinery Co. and are Squirrel Cage Induction
Motors intended for general purpose industrial /
arduous mining applications and meet all relevant
sections of the Australian, New Zealand and
International Standards detailed herein.

Electrical Design and Standards


Altitude
Designed for operation at an altitude up to 1000
metres above sea level, refer to page 23 for higher
altitudes.
Ambient
Motors are designed to operate in ambient
conditions of -20C to +40C with motors being
capable for operation within an ambient of 50C.
Please refer to page 23 for operation in adverse
ambient conditions.
Direction of Rotation
Standard rotation is clockwise when viewed
from the drive end with the terminal marking
corresponding to incoming line markings.

two

Duty Rating
All motors have a maximum continuous duty
rating of S1 to AS60034-1. Other duty ratings are
available on request.
Electric Supply
Stock motors are designed for operation on a
380 ~ 415 Volt 3-Phase 50 Hz supply and are also
suitable for a 440~480 Volt 3-Phase 60 Hz supply.
Motors 4 kW and below are 380 ~ 415 Volt 50 Hz
STAR connected and may also be reconnected to
240 Volt 3-Phase 50 Hz DELTA configuration for use
with single phase input inverters.
Motors 5.5 kW and larger are 380 ~ 415 Volt
50 Hz DELTA connected.
Please refer to page 24 for Connection diagram.
Motors can be manufactured for supply systems
of up to 1100 Volts, 50 or 60 Hz on a factory made to
order basis or by local rewind / wind.
Motor Types / MEPS (Minimum Efficiency
Performance Standard)
All motors meet or exceed the requirements of
Australian New Zealand Standard AS/NZS1359.52004 3-Phase cage induction motors high efficiency
and minimum efficiency performance standards
requirements within the range of 0.75 kW to less
than 185 kW, 2 4 6 & 8 pole single speed, rated
S1 continuous duty, compliance as detailed herein.

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Standards and TECO compliance is detailed below


TECO Type
Designation

Frame
Size

Output
kW

Name
plated

Efficiency
Level

AEEB-NE

D63 ~ D90L

< 0.75

TECO

Not applicable

0.75 ~ 185

TECO
MAX-E2

MEPS table B2
or B3 as
nominated

AEHB ~ AEHD D80 ~ D315M

* MEPS covers motors less than 185kW.


* Larger sizes also available, refer to TECO for details.

enamelled Class H copper wire, impregnated with


a solventless resin and are tropic proof rated as
standard. Other insulation materials used meet
Class F as a minimum.
Windings are designed with a temperature rise
of less than Class B (80C), however, in most cases
are less than Class E (75C) for long motor life,
providing superior thermal reserve in abnormal
conditions.

Performance
Motors are designed to meet the performance
requirements of Design N as per AS1359.41, normal
torque for Direct On Line starting.

Testing
In addition to a full program of tests during
manufacture each motor is subjected to routine

Motors are also suitable for other means of

tests to AS60034-1 prior to despatch. Performance

starting, depending on load characteristics, please

testing (witnessed or unwitnessed) can be arranged

refer to TECO.

for factory made to order motors.

Other performance characteristics can be manufactured to suit any special requirement.

Variable Speed Drive (VSD) Suitability


Motors are suitable for VSD operation, subject to

Standards

torque and speed limitations depending on the load

Motors are designed, manufactured and tested in


accordance with AS1359. Frame sizes comply with
AS1359.30 Australian / British allocations.
Motors also meet the requirements of European
Directives where applicable and are CE marked.
For EMC C-tick requirements to AS1044,
squirrel cage induction motors fall into Compliance
Level 1 Voluntary category.
TECO has a Declaration of Conformity and is
a registered user of C-tick number N121, which
covers TECO squirrel cage induction motors.
For other foreign standards i.e. UL, CSA etc.,
please refer to TECO.

characteristics and correct installation of motor


and drive.
For Variable torque loads (centrifugal pumps
and fans) for speeds between 5 ~ 50 Hz derating
is not normally required, outside of this range
please check with TECO for motor suitability.
Force cooling units are also available when
necessary (please refer to page 20 for force cooling
details and page 31 for VSD rating).
Electro-discharge machining of motor bearings
can be a concern in some applications with larger
motors on VSDs (please refer page 32 for our
preventative measures).

Stator and Windings


The stator is made up of exceptional high grade,

Winding Protection

low loss insulated cold rolled electro magnetic

Motors D160 and larger are fitted with PTC

silicon steel laminations for maximum efficiency

thermistor protection (P140) within the windings

and low core losses.

(one per phase) with the leads terminated in the

Windings are random wound with double

main terminal box.

TECO AUSTRALIA PTY LTD

three

RETURN TO INDEX

Mechanical Design and Standards


Balance
All rotors are dynamically balanced with a half key
to Class N or better, in accordance with AS1359.114.

TECO Through Flush


Grease Relief
Bearing System
with Gamma
Seal to D250

Bearing and Lubrication System


Frame
Size

Poles

DE Bearing

NDE
bearing

Greasing/
Shaft Seal

D63 ~ D90L

Ball

Ball

Greased for life/


Gamma***

D100L ~ D160L

Ball

Ball

Greased
for life (GR)/
Gamma***

D180M ~ D250M

Ball

Ball

Grease relief

D280S ~ D355*

Ball

Ball

Grease relief
brass dust flinger

D63 ~ D90L

4 and Above

Ball

Ball

Greased for life/


Gamma***

D100L ~ D132M

4 and Above

Ball

Ball

Greased
for life (GR)/
Gamma***

D160M ~
D180M/L

4 and Above

Ball (Roller)

Ball

Greased
for life (GR) /
Gamma***

D200L ~ D225M

4 and Above

Ball (Roller)

Ball

Grease relief/
Gamma

D250S ~ D250M

4 and Above

Roller (Ball)

Ball

Greased relief/
Gamma

D280S ~ D315M

4 and Above

Roller (Ball)

Ball

Grease relief/
brass dust flinger

TECO Through Flush


Grease Relief Bearing
System with Brass
Dust Flinger
D280-315

Key: (options in the parentheses are alternatives)



GR Grease Relief
* Larger sizes also available, refer to TECO for details.
** Ball bearing fitted for direct drive applications, Roller can
be fitted for Belt Drive applications, please refer to TECO.
*** Oil Seal fitted to flange/Cface.

2 Pole motors up to D180 are suitable


for direct drive or belt drive.
2 Pole motors D200 and larger are suitable
for direct drive, belt drive above D200
please refer to TECO.
4 Pole and larger; up to and including
D315MC, motor are suitable for Belt or
Direct Drive.

The fitment of rotating inner & outer labyrinth


seals achieves effective sealing from ingress of
contamination.
This is a true pressure grease relief system
where the grease enters the back of the bearing
then is forced through to the front and is expelled
through a large external discharge chute.
This system will not allow over greasing to
affect the performance of the bearings. This type
of grease replenishment system will not allow
contaminants to be pushed back into the bearing
itself, which can cause premature bearing failure.

four

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Bearing Lubrication Instructions


Table 1: Bearing Grease Schedule
- 50Hz Operation
Bearing Number
62XX

8 Pole

6 Pole

4 Pole

2 Pole

6210

63XX

12

72XX

13

73XX

14

2000Hrs
1000Hrs

15

3000Hrs

16

720Hrs

17

2000Hrs

18
20
22
24

1500Hrs

26

2000Hrs 1000Hrs

Bearing Number
NU2XX

NU214

NU3XX

15

8 Pole

6 Pole

4 Pole
2000Hrs

16
17
18

3000Hrs

1500Hrs

20
22

1000Hrs

24
26

2000Hrs

500Hrs

Table 2: Bearing Grease Fill


Bearing
Number

Amount
(grams)

Bearing
Number

Amount
(grams)

62XX

6210

30

63XX

6310

72XX

12

40

73XX

12

40
60

NU2XX

13

50

NU3XX

13

80

14

50

14

80

15

60

15

100

16

60

16

100

17

80

17

120

18

80

18

120

20

100

20

160

22

120

22

220

24

120

24

270

26

300

Notes: 1. Please ensure bearings are fully purged during


commissioning, thereafter adhere to the above
greasing schedule.

2. Replenishment of grease recommended when
motor is running.

3. Do not mix dissimilar greases.

4. TECO recommends use of SHELL ALVANIA RL3
Lithium based grease on motors frame size up
to and including D315M.

When do motors require greasing?


At initial start during commissioning.
If the motor has been out of service for three (3)
months or longer.
At predetermined intervals, please refer to Table 1.
What to do prior to greasing?
Check the motor nameplate for the type of grease
and check that the grease you plan to use is fully
compatible.
Clean the grease nipples on the motor and the
grease gun discharge connection.
Ensure that the grease discharge chute on the
motor is clean and not blocked with old hard grease.
How to effectively grease an electric motor?
The electric motor must be running with
preferably the bearings up to normal operating
temperature.
Pump-in of the required quantity of grease as
in Table 2 to each bearing and allow to settle.
After 5-10 minutes pump-in the other of the
required grease quantity.
Please note it is normal to see an increase in
the bearing temperature during the greasing
procedure.
Expelled grease should be evident at the rotating
labyrinth seal and within the discharge chute.
30 minutes after the greasing procedure the
bearing temperatures should return to normal, if
not, please check that there are no other reasons
for an increase in bearing temperature, i.e.
misalignment, high vibration etc.
Bearing False Brinelling Protection
A bearing, will experience false brinelling when
it is not turning and subjected to vibrations of
some sort. This is generally in cylindrical roller
type bought about from transportation without
an effective shaft lock to prevent movement or
from vibration of the motor when de-energized.
Because the bearing is not turning, the grease
or oil will be gradually removed from the ball
or roller contacts ending in metal to metal
contact. Wear is then allowed to take place
and the damage will cause the bearing to fail
prematurely after start up. TECO do fit a shaft
locks on D180 2 pole ~ D200 4 pole and larger to
prevent false brinelling.

Extensive shaft
locking clamp on
D280-315M
TECO motor

TECO AUSTRALIA PTY LTD

five

RETURN TO INDEX

Cooling System
Cooling is Totally Enclosed Fan Cooled (TEFC), with
integrally cast cooling fins on frame and endshields,
fitted with external fan (IC411) to AS60034-7.
The cooling fans are bi-directional and low noise
as standard.
Finish
All external components are shot blast to a near
white finish. A durable coat of Alkyd Resin primer
giving excellent corrosion protection follows this
preparation. The complete motor is then finish
coated with Alkyd Resin Gloss Enamel in TECO Grey
(Munsell 7.5BG 4/2).
Other paint systems and colours are available
upon request, including chemical duty two pack
epoxy paint systems.
Hardware
All hardware is electro zinc plated for better
corrosion resistance.
Stainless steel hardware can be offered as an
alternative, please contact TECO for the surcharge
to provide this feature.
MAX-E3-H66
Please refer to separate catalogue for details
on TECO High Efficiency MAX-E3-H66 motors.

Motor Construction
Motor frames are high grade Cast Iron with
integrally cast feet and cast iron end shields, suiting
mining applications.
Castings are machined to close tolerances in
order to ensure accurate alignment with minimum
vibration.
Standard Materials of Construction
Frame Size

External Fan

Fan Cover

Terminal Box

D63~D160

CPP (CI)

HDPS (CI)

CI

D180 (2 pole)

CPP (CI)

HDPS (CI)

CI

D180 (4 pole)

CI

HDPS (CI)

CI

D200~D315M

CI

HDPS (CI)

CI

D80~D132

CPP (CI)

HDPS (CI)

CI

D160~D315M

CI

HDPS (CI)

CI

Key: (material in parentheses is alternative)



CPP Conductive Polypropylene (Non Sparking)

CI - Cast Iron

HDPS - Heavy Duty Pressed Steel
* Larger sizes are also available, please refer to TECO for details.

Protection (IP rating stock motors)


All motors are rated IP66, thereby providing
excellent protection against the ingress of dust and
water.
Rating Plate
A stainless steel rating plate containing all details
as specified in AS60034-1 including bearing sizes
are fitted to all motors. Rating plate also confirms
compliance with MEPS Efficiency Standard.

Mounting
Motors are available in the following mountings,
refer to page 21 for IM codes of mountings.
Foot mounted
Foot and Flange mounted
Flange mounted
Foot and C Face mounted
C Face mounted

six

As fited to motors 0.75kw and larger.

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Rotor Assembly

Terminal Box

As per the stator, the rotor core is made up of

On motors up to and including D315M, the

exceptional high grade, low loss insulated cold

terminal box is mounted on the right hand side

rolled electro magnetic steel laminations for

viewed from drive end and can be transferred to

maximum efficiency and low core losses.

the left hand side upon request.

The rotor cage is pressure die cast high


conductivity aluminium with wafter blades and
balance supports integrally cast onto the rotor
endrings.
On some larger frame size motors, the rotor is
of copper/copper alloy rotor bar construction. This
rotor construction offers superior performance and

All terminal boxes have one-piece neoprene


gaskets between frame, box and gland plate and
can be rotated through 360 in 90 increments.
An internal earth is provided within the motor
terminal box.
Maximum Cable Sizes
Frame Size

Maximium Cable Size

D63 ~ D71

2.5 mm

D80 ~ D112

10 mm

brazing provides an all at once uniform braze that

D132 ~ D180

50 mm

reduces stresses and hot spots in the joint, which

D200 ~ D225

95 mm

can cause premature fatigue and rotor bar failure.

D250 ~ D315M*

185 mm

reliability. TECO utilizes high frequency induction


brazing as a means to enhance the structural
integrity of the rotor bar to endring joint. Induction

The rotor is a press fit onto the high tensile steel


shaft (ANSI1040) and is also keyed onto the shaft on
motor frames D200 and larger.

Induction Brazing

Finished Rotor and Shaft Assemblies

Notes: Sizes based on -


3 core + Earth Copper PVC Insulated / PVC Sheathed or
3 core + Earth Copper PVC Insulated / Steel Wire Armoured.
Standard Cast Iron terminal box *
Larger teminal boxes available, please refer to TECO.

Options
Some available options in this range are as follows:
Airstream rated IC418
Anti-condensation heaters
Auxiliary terminal boxes for Thermistor /

Heater / RTD terminations
Electromechanical fail safe Brake Motors
Cooling Tower application
Crane rated motors
Double / non standard shaft extensions
Encoder / Tacho
Force ventilation IC416
Induction Generators
Insulated bearing
IP66 enclosure
Multi-speed motors
Resistance temperature detectors (RTDs)

winding and / or bearings
Rotor Groundary brush
Smoke spill to BS7436 to 185 kW
Special paint systems / colours
Stainless steel fasteners
Thermistor protection (on motor frames <D160)
Others on request
TECO AUSTRALIA PTY LTD

seven

RETURN TO INDEX

Typical Performance Data MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Cage Induction Motors
63 to 315 Frame (415V 50Hz)
Output Full Frame
Efficiency
kW
Load Size
Full
3/4
1/2
Speed
Load Load Load
RPM
(%)
(%)
(%)
0.18

0.37

0.55

0.75

1.1

1.5

2.2

5.5

7.5

Notes:





eight

1.
2.
3.
4.
5.
6.
7.

Power Factor
Full
Load
(%)

3/4
Load
(%)

1/2
Load
(%)

Current
Torque
Inertia
Noise Weight
Full Locked Full Locked Pull Break- Rotor MaxLoad Level Foot
Load Rotor Load Rotor Up
Down J=GD2/4 J=GD2/4 dB(A) Mount
(A)
(%)
N-m %FLT %FLT %FLT Kg-m2 Kg-m2
Kgs

2740

63

61.0

59.5

55.0

77.5

69.0

57.0

0.55

455

0.63

330

330

330

0.0005

0.022

52

1350

63

63.5

63.0

58.0

70.0

61.0

49.0

0.58

431

1.27

240

230

260

0.0008

0.103

48

11

910

71

61.0

57.0

50.0

64.0

55.0

44.0

0.66

379

1.89

260

240

280

0.0018

0.175

45

12

705

80

52.0

48.0

39.0

47.0

41.0

34.0

1.06

302

2.44

360

350

370

0.0025

0.543

44

16

2800

71

75.0

74.0

70.0

85.0

78.0

64.0

0.81

593

1.26

320

270

310

0.0008

0.043

54

12
13

1405

71

74.5

73.0

68.5

69.5

60.5

48.0

1.00

530

2.51

325

270

305

0.0013

0.198

50

920

80

72.5

72.0

68.5

72.0

62.5

49.0

0.99

535

3.84

230

215

240

0.0025

0.338

49

18

710

90S

70.5

68.0

62.5

60.0

51.0

39.5

1.23

388

4.98

195

190

265

0.0045

1.04

49

22

2780

71

73.0

72.0

68.0

83.0

75.0

62.0

1.28

563

1.89

300

260

280

0.0008

0.062

53

16

1405

80

71.5

70.5

65.0

74.0

65.0

52.0

1.47

524

3.74

260

230

280

0.0018

0.291

48

18

910

80

68.0

68.0

63.0

72.0

62.0

49.0

1.59

365

5.77

230

210

230

0.0030

0.498

48

18

690

90L

70.0

70.0

66.0

70.0

61.0

49.0

1.59

365

7.61

170

145

205

0.0058

1.54

47

27

2860

80 **

83.0

82.0

79.0

85.0

78.5

65.5

1.47

1,020

2.50

340

340

380

0.0015

0.081

57

18

1420

80

82.5

82.5

80.5

71.0

61.0

47.0

1.77

678

5.04

330

320

330

0.0028

0.353

50

18

940

90S

78.0

78.0

75.0

67.5

58.0

46.0

1.97

609

7.62

200

200

250

0.0048

0.913

54

25

695

100L

76.5

76.5

73.0

60.0

51.0

39.0

2.26

442

10.3

230

215

230

0.0088

1.89

49

31

2840

80 **

84.5

84.0

82.0

87.5

82.0

70.5

2.11

947

3.70

300

290

330

0.0018

0.110

53

21

1415

90S

84.0

85.0

84.0

80.0

72.5

60.0

2.32

690

7.42

250

215

270

0.0043

0.523

46

27

940

90L

82.0

80.0

77.0

69.0

60.0

48.0

2.75

582

11.2

240

230

290

0.0063

1.40

42

26

695

100L

78.0

79.5

77.0

64.5

55.5

43.0

3.09

485

15.1

210

200

215

0.0113

2.74

49

37

2855

90S

85.0

85.5

83.0

85.5

80.5

68.0

2.86

804

5.02

330

300

330

0.0028

0.145

54

24

1430

90L

85.0

85.0

83.0

75.0

66.5

53.0

3.26

706

10.0

300

240

310

0.0058

0.670

46

30

930

100L

83.0

83.0

81.5

78.0

71.5

60.0

3.21

623

15.4

240

200

250

0.0138

1.83

44

36

705

112M

79.5

79.0

77.0

59.0

49.0

39.0

4.43

451

20.3

200

170

230

0.0150

3.65

49

45

2855

90L

86.0

86.5

85.5

88.0

83.0

72.0

4.11

803

7.36

320

290

330

0.0038

0.213

59

29

1440

100L

86.5

86.5

85.0

82.5

76.0

63.5

4.36

757

14.6

290

250

300

0.0103

1.04

46

37

955

112M

84.5

85.0

83.0

74.5

67.0

54.5

4.95

606

22.0

210

190

260

0.0193

2.68

44

43

710

132S

82.0

81.5

79.0

65.0

56.0

43.0

5.84

514

29.6

250

230

280

0.0385

5.29

49

65

2875

100L**

88.5

88.5

87.0

87.5

83.0

73.0

5.36

932

9.97

400

320

370

0.0063

0.280

57

38
43

1430

100L

87.5

87.5

87.0

82.5

77.0

65.0

5.95

748

20.0

290

270

310

0.0125

1.34

46

965

132S**

88.5

87.5

86.0

81.0

75.0

63.0

5.79

777

29.7

200

170

290

0.0385

3.50

51

71

710

132M

83.5

83.5

81.0

65.0

55.0

42.0

7.65

523

40.4

250

235

290

0.0480

6.97

50

75

2880

112M **

89.5

90.0

89.0

91.0

88.5

81.0

7.01

856

13.3

280

240

350

0.0115

0.383

57

48

1445

112M

89.0

89.0

88.0

84.0

80.0

68.5

7.64

785

26.4

240

180

300

0.0208

1.81

48

48

970

132M **

89.5

89.0

87.0

79.0

72.5

60.0

8.07

743

39.4

210

180

310

0.0515

4.75

51

87

720

160M

84.5

84.0

81.5

73.0

65.0

52.5

9.25

541

53.1

200

180

250

0.0878

9.51

51

118

2915

132S**

91.5

91.5

90.5

88.0

85.0

78.5

9.67

776

18.0

220

190

280

0.0190

0.505

64

71

1460

132S

90.5

90.5

89.0

82.5

76.0

63.5

10.40

817

36.0

270

220

320

0.0333

2.37

53

72

960

132M

89.0

88.5

88.0

82.0

77.0

66.0

10.70

654

54.7

190

170

270

0.0543

6.33

47

90

715

160M

85.0

85.5

83.5

73.0

65.0

52.0

12.50

520

73.5

170

160

230

0.123

12.7

54

118

2895

132S**

91.0

91.0

90.0

80.0

74.0

63.0

14.30

629

24.7

210

180

260

0.0190

0.670

64

84

1455

132M

91.0

91.0

90.0

85.0

80.0

68.5

13.40

821

49.2

270

220

320

0.0358

3.10

56

82

970

160M **

91.0

91.0

90.0

81.0

75.0

64.0

14.10

674

73.8

240

200

260

0.121

8.34

55

138

720

160L

87.0

87.0

85.0

72.0

64.0

51.0

16.60

572

99.5

195

185

270

0.147

16.6

55

155

All figures are based on tests carried out on 415 Volt3-Phase Motors.
Test Method: AS1359.5, Method B.
Tolerance: refer page 30
** motors comply to MEPS 2006 High Efficiency requirements.
dB(A): Mean Sound Pressure Level on no load at 1 metre.
Motor data 8 pole and slower speeds not listed available on request.
Data subject to change without notice.

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Typical Performance Data MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Cage Induction Motors
63 to 315 Frame (415V 50Hz)
Output Full Frame
kW
Size
Load
Speed
RPM
11

15

18.5

22

30

37

45

55

75

90

110

132

150
185

Notes:


1.
2.
3.
4.

Efficiency

Power Factor

Full
Load
(%)

3/4
Load
(%)

1/2
Load
(%)

Full
Load
(%)

3/4
Load
(%)

1/2
Load
(%)

Current

Torque

Inertia

Noise Weight
Full Locked Full Locked Pull Break- Rotor MaxLoad Level Foot
Load Rotor Load Rotor Up
Down J=GD2/4 J=GD2/4 dB(A) Mount
(A)
(%)
N-m %FLT %FLT %FLT Kg-m2 Kg-m2
Kgs

2935

160M **

92.5

92.5

92.0

91.5

89.0

84.5

18.40

761

35.8

230

200

280

0.0458

0.973

70

128

1460

160M **

92.5

92.5

92.0

85.0

82.0

74.0

19.80

707

72.0

230

180

270

0.0918

4.57

56

133
159

975

160L

91.0

90.5

89.0

79.0

72.5

60.0

21.7

737

108

280

230

280

0.158

12.2

52

720

180L

87.5

88.0

87.5

78.5

74.0

72.5

22.7

529

146

180

160

215

0.314

24.3

56

210

2935

160M **

92.5

92.0

91.5

91.0

88.0

81.0

24.70

789

48.8

240

210

290

0.0458

1.28

70

130

1460

160L**

93.0

93.0

92.5

88.0

84.5

76.5

25.40

728

98.1

230

180

270

0.116

6.02

56

153

970

180LC **

92.0

92.0

92.0

84.0

79.5

71.5

26.90

613

148

230

190

250

0.336

15.9

58

215

720

200LC

89.0

89.5

89.5

81.5

78.5

70.5

28.6

454

199

150

130

180

0.445

31.8

57

282

2925

160L**

93.0

93.0

93.0

91.5

89.5

84.0

30.50

803

60.4

260

210

300

0.0593

1.55

72

148

1470

180MC **

94.0

94.0

93.5

85.0

81.0

72.5

32.50

754

120

240

180

270

0.177

7.42

63

194

975

200LC **

93.0

93.5

93.0

78.0

74.0

64.0

35.80

615

181

230

200

250

0.459

19.7

55

285
334

725

225S

90.0

90.5

90.0

77.0

72.0

61.0

37.4

508

244

190

180

160

0.591

39.2

58

2935

180MA**

93.5

93.5

92.5

87.5

84.5

76.0

38.1

787

71.6

250

210

300

0.0708

1.89

72

194

1465

180LC **

94.0

94.0

93.5

86.0

82.5

74.0

38.5

701

143

230

180

270

0.198

8.76

64

215
300

975

200LC **

93.5

93.5

93.5

79.0

75.0

67.0

42.2

592

216

220

190

220

0.521

23.4

54

735

225MC **

92.5

92.5

92.0

78.0

73.5

63.0

43.2

509

286

190

170

195

0.709

46.8

58

375

2955

200LA**

94.0

94.0

93.0

89.0

87.5

83.5

49.6

685

97.0

175

150

260

0.151

2.43

76

286
300

1470

200LC **

94.5

94.5

94.5

87.0

85.5

78.0

50.5

773

195

230

190

270

0.364

11.5

64

980

225MC **

94.0

94.0

93.5

85.5

82.0

75.0

51.7

590

292

210

190

230

0.756

30.5

61

390

735

250SC

92.5

92.5

92.0

76.5

71.0

61.0

58.7

545

390

205

180

225

1.025

61.2

65

480

2950

200LA**

94.5

94.5

93.5

90.0

88.0

84.5

61.0

656

120

155

135

260

0.189

2.98

76

312

1475

225SC **

95.0

95.0

94.5

85.0

81.0

73.0

64.3

669

240

200

180

240

0.474

14.1

69

359

985

250SC **

94.0

94.5

94.0

86.5

83.5

76.0

63.8

634

359

210

200

250

1.049

37.8

64

480

735

250MC

93.0

93.0

92.0

78.0

74.0

63.0

71.5

559

481

210

180

235

1.225

75.5

68

554

2955

225MA

94.5

94.5

93.5

92.0

91.0

88.0

72.0

667

145

140

130

230

0.311

3.53

78

373

1475

225MC **

95.0

95.0

94.5

85.0

81.0

72.5

77.1

642

291

200

175

250

0.495

16.7

69

387
554

985

250MC **

94.5

95.0

94.5

87.5

85.0

77.5

75.3

704

436

230

200

250

1.277

44.8

66

2960

250SA**

95.0

94.5

94.0

89.5

88.0

87.0

91.5

705

177

150

130

250

0.387

4.32

78

470

1480

250SC **

95.5

95.0

94.5

87.0

84.0

77.0

93.7

700

355

230

200

260

0.978

20.3

71

528

984

280SC **

95.0

94.5

94.0

85.0

82.5

75.0

94.8

680

534

165

140

230

2.125

55.0

77

650

2960

250MA**

95.5

95.5

95.0

91.0

88.0

85.0

119.0

693

242

140

130

250

0.454

5.60

78

548

1480

250MC **

95.5

95.5

95.0

87.0

84.0

77.0

125.0

648

484

220

180

240

1.123

26.8

72

574

984

280MC **

95.3

94.9

94.8

86.0

83.3

76.0

127

689

728

160

136

230

2.775

46.8

77

730

2960

280SA

95.4

94.8

94.0

89.0

87.5

82.0

147

717

290

130

110

230

0.725

6.88

83

650

1480

280SC

95.6

95.0

94.2

87.0

84.2

78.0

150

703

581

160

136

230

2.025

33.0

80

700

985

315SC

95.3

94.8

94.3

86.0

83.3

76.0

153

690

873

155

131

230

4.275

88.2

77

920

2960

280MA

95.4

94.8

94.0

89.7

88.0

82.0

179

721

355

120

102

230

0.850

8.08

83

700

1482

280MC

95.8

95.2

94.4

88.0

84.5

78.5

182

709

709

155

131

230

2.375

39.0

80

850

985

315MC **

95.8

95.3

94.8

86.2

84.0

76.5

185

697

1067

150

127

220

4.975

105

77

1010

2976

315SA

95.8

95.2

94.3

90.0

88.0

83.0

213

723

424

115

98

220

1.625

9.13

83

840

1482

315SC **

96.2

95.6

94.8

88.5

85.0

79.5

216

713

851

150

127

220

2.800

44.0

80

940

986

315MC

95.8

95.3

94.8

86.2

84.5

77.5

222

694

1279

150

127

220

5.050

120

77

1050

2976

315MA

96.0

95.4

94.5

90.3

89.0

83.5

241

726

481

110

94

220

1.625

10.5

83

920

1485

315MC

96.2

95.6

94.8

88.5

85.0

80.0

245

714

965

150

127

220

3.650

50.5

80

930

2982

315MA

96.0

95.4

94.5

90.3

89.2

83.5

297

724

593

105

91

220

1.975

12.8

83

1000

1486

315MB

96.2

95.6

94.8

89.0

85.6

80.5

301

714

1189

140

119

220

3.825

61.8

80

1100

All figures are based on tests carried out on 415 Volt3-Phase Motors.
Test Method: AS1359.5, Method B.
Tolerance: refer page 30
** motors comply to MEPS 2006 High Efficiency requirements.

5. dB(A): Mean Sound Pressure Level on no load at 1 metre.


6. Motor data 8 pole and slower speeds not listed available on request.
7. Data subject to change without notice.

TECO AUSTRALIA PTY LTD

nine

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Cage Induction Motors
Frame 63 - 132 Foot Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 1

Output (kW)
2P

4P

6P

8P

Frame
Size

0.18

0.18

0.37 / 0.55

0.37

0.18

0.75 / 1.1

0.55 / 0.75

0.37 / 0.55

Fig.
No.

Dimensions (mm)
A

AA

AB

AC

AD

AE

BB

HA

HC

63

100

28

120

144

138

100

80

100

40

63

135

71

112

35.5

140

162

148

110

90

115

45

71

152

0.18

80

125

35.5

155

177

179

130

100

130

50

80

168

HD

1.5

1.1

0.75

0.37

90S

140

35.5

170

200

192

143

100

130

56

90

10

190

2.2

1.5

1.1

0.55

90L

140

35.5

170

200

192

143

125

150

56

90

10

190

2.2 / 3

1.5

0.75 / 1.1

100L

160

45

195

219

202

153

140

175

63

100

12.5

243
265

2.2

1.5

112M

190

45

224

238

211

162

140

175

70

112

14

5.5 / 7.5

5.5

2.2

132S

216

45

250

273

249

187

140

175

89

132

16

310

7.5

4 / 5.5

132M

216

45

250

273

249

187

178

212

89

132

16

310

Shaft Extension

Bearings

Frame
Size

HE

KK

LE

ED

GA

DH

DE

NDE

63

10

M20 P1.5

219

76

11

23

18

8.5

12.5

M4 8

6201ZZ

6201ZZ

71

35

M20 P1.5

250.5

85.5

14

30

24

11

16

M5 10

6202ZZ

6202ZZ

80

13

10

M25 P1.5

282.5

92.5

19

40

25

15.5

21.5

M6 12

6204ZZ

6204ZZ

90S

23

10

M25 P1.5

307.5

101.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

90L

23

10

M25 P1.5

332.5

101.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

100L

33

12

M25 P1.5

374.5

111.5

28

60

40

24

31

M10 20

6206ZZ

6305ZZ

112M

45

12

M25 P1.5

391.5

121.5

28

60

40

24

31

M10 20

6306ZZ

6306ZZ

132S

58

12

M40 P1.5

454

145

38

80

56

10

33

41

M12 24

6308ZZ

6306ZZ

132M

58

12

M40 P1.5

492

145

38

80

56

10

33

41

M12 24

6308ZZ

6306ZZ

Notes:

10

Fig. 2

ten

1. Tolerance: Refer to page 30.


2. Data subject to change without notice and should not be used for installation purposes.

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Cage Induction Motors
Frame 160 - 250 Foot Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 4

Fig. 3

Output (kW)
2P

4P

6P

8P

Frame
Size

11 / 15

11

7.5

4 / 5.5

160M

18.5

15

11

7.5

160L

22

180MA

18.5

180MC

22

15

11

180LC

Fig.
No.
3
4
3

Dimensions (mm)
A

AA

AB

AC

AD

AE

BB

HA

HD

254

50

300

334

287

225

210

250

108

160

18

377

254

50

300

334

287

225

254

300

108

160

18

377

279

75

355

382

312

250

241

297

121

180

20

421

279

75

355

382

312

250

241

297

121

180

20

421

279

75

355

382

312

250

279

335

121

180

20

421

30 / 37

200LA

318

80

400

420

374

287

305

365

133

200

25

469

30

18.5 / 22

15

200LC

318

80

400

420

374

287

305

365

133

200

25

469

37

18.5

225SC

356

90

450

458

427

330

286

350

149

225

30

524

45

225MA

356

90

450

458

427

330

311

375

149

225

30

524

356

90

450

458

427

330

311

375

149

225

30

524

406

100

500

510

493

375

311

385

168

250

36

575

45

30

22

225MC

55

250SA

55

37

30

250SC

406

100

500

510

493

375

311

385

168

250

36

575

75

250MA

406

100

500

510

493

375

349

425

168

250

36

575

75

45

37

250MC

406

100

500

510

493

375

349

425

168

250

36

575

Shaft Extension

Bearings

Frame
Size

HE

KK

LE

ED

GA

DH

DE

NDE

160M

83

14.5

M40 P1.5

608

180

42

110

80

12

37

45

M16 32

6309ZZ

6307ZZ

160L

83

14.5

M40 P1.5

652

180

42

110

80

12

37

45

M16 32

6309ZZ

6307ZZ

180MA

103

14.5

M40 P1.5

672

200

48

110

80

14

42.5

51.5

M16 32

(6211C3)

(6211C3)

180MC

103

14.5

M40 P1.5

672

200

48

110

80

14

42.5

51.5

M16 32

6311ZZ

6310ZZ

180LC

103

14.5

M40 P1.5

710

200

48

110

80

14

42.5

51.5

M16 32

6311ZZ

6310ZZ

200LA

88

18.5

M50 P1.5

770

222

55

110

80

16

49

59

M20 40

(6312C3)

(6212C3)

200LC

88

18.5

M50 P1.5

770

222

55

110

80

16

49

59

M20 40

6312

6212

225SC

57

18.5

M50 P1.5

816

241

60

140

110

18

53

64

M20 40

6313

6213
(6212C3)

225MA

57

18.5

M50 P1.5

811

241

55

110

80

16

49

59

M20 40

(6312C3)

225MC

57

18.5

M50 P1.5

841

241

60

140

110

18

53

64

M20 40

6313

6213

250SA

42

24

M63 P1.5

882.5

263.5

60

140

110

18

53

64

M20 40

(6313C3)

(6213C3)

250SC

42

24

M63 P1.5

882.5

263.5

70

140

110

20

62.5

74.5

M20 40

NU316

6313

250MA

42

24

M63 P1.5

920.5

263.5

60

140

110

18

53

64

M20 40

(6313C3)

(6213C3)

250MC

42

24

M63 P1.5

920.5

263.5

70

140

110

20

62.5

74.5

M20 40

NU316

6313

Notes: 1. Tolerance: Refer to page 30.



2. Data subject to change without notice and
should not be used for installation purposes.

TECO AUSTRALIA PTY LTD

eleven

11

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Cage Induction Motors
Frame 280 - 315M Foot Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Output (kW)
2P

4P

6P

8P

AA

AB

AC

AD

AE

AF

BA

BB

HA

90

280SA

457

110

560

603

600

445

293

368

110

445

190

280

30

90

55

45

280SC

457

110

560

603

600

445

293

368

110

445

190

280

30

110

280MA

457

110

560

603

600

445

293

419

130

495

190

280

30

110

75

55

280MC

457

110

560

603

600

445

293

419

130

495

190

280

30

132

315SA

508

115

615

642

620

465

312

406

115

490

216

315

35

132

90

75

315SC

508

115

615

642

620

465

312

406

115

490

216

315

35

150 / 185

315MA

508

115

615

642

620

465

312

457

115

540

216

315

35

150

110 / 132

90

315MC

508

115

615

642

620

465

312

457

115

540

216

315

35

185

315MB

508

115

615

642

620

465

312

457

115

540

216

315

35

185

315MC**

508

115

615

642

703

482

312

457

115

540

216

315

35

Shaft Extension
HD

HE

KK

LE

ED

EE

GA

DH

DE

NDE

280SA

651

82

24

M63x1.5

1042

344

65

140

110

134

18

58

69

M20x30

6314C3

6314C3

280SC

651

82

24

M63x1.5

1072

344

80

170

140

157

22

71

85

M20x30

NU318

6316

280MA

651

82

24

M63x1.5

1092

343

65

140

110

134

18

58

69

M20x30

6314C3

6314C3

280MC

651

82

24

M63x1.5

1122

343

80

170

140

157

22

71

85

M20x30

NU318

6316

315SA

723

112

28

M63x1.5

1131

369

65

140

110

134

18

58

69

M20x30

6314C3

6314C3

315SC

723

112

28

M63x1.5

1161

369

85

170

140

157

22

76

90

M20x30

NU320

6316

315MA

723

112

28

M63x1.5

1182

369

65

140

110

134

18

58

69

M20x30

6314C3

6314C3

315MC

723

112

28

M63x1.5

1212

369

85

170

140

157

22

76

90

M20x30

NU320

6316

315MB

723

112

28

M63x1.5

1212

369

85

170

140

157

22

76

90

M20x30

NU320

6316

315MC**

723

112

28

BLANK

1212

369

95

170

140

157

25

86

100

M24x48

NU320

6316

1. Tolerance refer to page 30.


2. Usable Shaft Length: EE
3. ** 185kW motor in D315MC frame with fabricated
steel terminal box and oversize DE shaft.
4. Data subject to change without notice and
should not be used for installation purposes.

MAX-E2 Motor

Frame sizes D280-315m

12

Bearings

Frame
Size

Notes:


Dimensions (mm)

Frame
Size

twelve

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Induction Motors
Frame 63 - 132 Flange Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 1

Fig. 2

Output (kW)
2P

4P

6P

8P

Frame
Size

0.18

0.18

63

0.37 / 0.55

0.37

0.18

71

0.75 / 1.1

0.55 / 0.75

0.37 / 0.55

0.18

80

1.5

1.1

0.75

0.37

90S

2.2

1.5

1.1

0.55

90L

2.2 / 3

1.5

0.75 / 1.1

100L

2.2

1.5

112M

5.5 / 7.5

5.5

2.2

132S

7.5

4 / 5.5

132M

Fig.
No.
1
2

Flange

AC

AD

AE

HB

KK

LA

LB

LL

144

138

100

M20 P1.5

225

12

235

115

95

140

162

148

110

M20 P1.5

278

12

248

17

130

110

160

177

179

130

M25 P1.5

280

12

240

15

165

130

200

200

192

143

M25 P1.5

347

12

297

15

165

130

200

200

192

143

M25 P1.5

372

12

322

15

165

130

200

219

202

153

140

M25 P1.5

375

16

315

15

215

180

250

238

211

162

150

M25 P1.5

431

16

371

15

215

180

250

273

249

187

169

M40 P1.5

454

20

374

13

265

230

300

273

249

187

169

M40 P1.5

484

20

404

13

265

230

300

Flange

Dimensions (mm)

Shaft Extension

Bearings

Frame
Size

ED

GA

DH

DE

NDE

63

10

11

23

18

8.5

12.5

M4 8

6201ZZ

6201ZZ

71

10

3.5

14

30

24

11

16

M5 10

6202ZZ

6202ZZ

80

12

3.5

19

40

25

15.5

21.5

M6 12

6204ZZ

6204ZZ

90S

12

3.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

90L

12

3.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

100L

14.5

28

60

40

24

31

M10 20

6206ZZ

6305ZZ

112M

14.5

28

60

40

24

31

M10 20

6306ZZ

6306ZZ

132S

14.5

38

80

56

10

33

41

M12 24

6308ZZ

6306ZZ

132M

14.5

38

80

56

10

33

41

M12 24

6308ZZ

6306ZZ

Notes:

1. Tolerance: Refer to page 30.


2. Lifting lugs not provided on frames D90 and smaller.
3. Data subject to change without notice and should not be used for installation purposes.

TECO AUSTRALIA PTY LTD

thirteen

13

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Induction Motors
Frame 160 - 250 Flange Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 3

Fig. 4

Output (kW)
2P

4P

6P

8P

AC

AD

AE

HB

KK

LA

LD

LL

11

7.5

4 / 5.5

160M

334

287

225

217

M40 P1.5

608

20

126

10

300

250

350

18.5

15

11

7.5

160L

334

287

225

217

M40 P1.5

652

20

148

10

300

250

350

180MA

382

312

250

241

M40 P1.5

672

20

155

10

300

250

350

382

312

250

241

M40 P1.5

672

20

155

10

300

250

350

180LC

382

312

250

241

M40 P1.5

710

20

174

10

300

250

350

200LA

420

374

287

260

M50 P1.5

770

20

154

20

350

300

400

18.5

180MC

22

15

11

30 / 37
30

18.5 / 22

37
30

15

200LC

420

374

287

260

M50 P1.5

770

20

154

20

350

300

400

225SC

458

427

330

286

M50 P1.5

816

22

94

30

400

350

450

225MA

458

427

330

286

M50 P1.5

811

22

107

30

400

350

450

225MC

458

427

330

286

M50 P1.5

841

22

107

30

400

350

450

510

493

375

312

M63 P1.5

882.5

22

86

30

500

450

550

22

55

250SA
55

37

30

75
75

45

18.5

45
45

Fig.
No.

Flange

11 / 15
22

37

250SC

510

493

375

312

M63 P1.5

882.5

22

86

30

500

450

550

250MA

510

493

375

312

M63 P1.5

920.5

22

105

30

500

450

550

250MC

510

493

375

312

M63 P1.5

920.5

22

105

30

500

450

550

Flange

Shaft Extension

Bearings

Frame
Size

ED

GA

DH

DE

NDE

160M

18.5

42

110

80

12

37

45

M16 32

6309ZZ

6307ZZ
6307ZZ

160L

18.5

42

110

80

12

37

45

M16 32

6309ZZ

180MA

18.5

48

110

80

14

42.5

51.5

M16 32

6211C3

6211C3

180MC

18.5

48

110

80

14

42.5

51.5

M16 32

6311ZZ

6310ZZ

180LC

18.5

48

110

80

14

42.5

51.5

M16 32

6311ZZ

6310ZZ

200LA

18.5

55

110

80

16

49

59

M20 40

6312C3

6212C3

200LC

18.5

55

110

80

16

49

59

M20 40

6312

6212

225SC

18.5

60

140

110

18

53

64

M20 40

6313

6213
6212C3

225MA

18.5

55

110

80

16

49

59

M20 40

6312C3

225MC

18.5

60

140

110

18

53

64

M20 40

6313

6213

250SA

18.5

60

140

110

18

53

64

M20 40

6313C3

6213C3

250SC

18.5

70

140

110

20

62.5

74.5

M20 40

NU316

6313

250MA

18.5

60

140

110

18

53

64

M20 40

6313C3

6213C3

250MC

18.5

70

140

110

20

62.5

74.5

M20 40

NU316

6313

Notes:

14

Dimensions (mm)

Frame
Size

1. Tolerance: Refer to page 30.


2. Data subject to change without notice and should not be used for installation purposes.

fourteen

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Induction Motors
Frame 63 - 200 Foot and Flange Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 1
Output (kW)
2P

4P

6P

8P

Frame
Size

0.18

0.18

63

0.37 / 0.55

0.37

0.18

71

0.75 / 1.1

0.55 / 0.75

0.37 / 0.55

0.18

80

1.5

1.1

0.75

0.37

2.2

1.5

1.1

0.55

Fig.
No.
2

Fig. 2
Dimensions (mm)
A

AA

AB

AD

AE

BB

HA

HC

HD

HE

KK

100

28

120

123

97

80

100

69

63

135

10

M20 P1.5

112

35.5

140

148

110

90

115

72

71

152

35

M20 P1.5

125

35.5

155

179

130

100

130

50

80

180

13

10

M25 P1.5

90S

140

35.5

170

192

143

100

130

95

90

10

190

23

10

M25 P1.5

90L

140

35.5

170

192

143

125

150

95

90

10

190

23

10

M25 P1.5

2.2 / 3

1.5

0.75 / 1.1

100L

2.2

1.5

112M

5.5 / 7.5

5.5

2.2

132S

216

45

250

7.5

4 / 5.5

132M

216

45

250

11 / 15

11

7.5

4 / 5.5

160M

254

50

300

287

225

18.5

15

11

7.5

160L

254

50

300

287

225

22

180MA

279

75

355

312

250

18.5

180MC

279

75

355

312

22

15

11

180LC

279

75

355

30/37

200LA

318

80

30

18.5 / 22

15

200LC

318

80

Frame
Size

160

45

195

202

153

140

175

103

100

12.5

243

33

12

M25 P1.5

190

45

224

211

162

140

175

110

112

14

265

45

12

M25 P1.5

249

187

140

175

139

132

16

310

58

12

M40 P1.5

249

187

178

212

139

132

16

310

58

12

M40 P1.5

210

250

108

160

18

377

83

14.5 M40 P1.5

254

300

108

160

18

377

83

14.5 M40 P1.5

241

297

121

180

20

421

103

14.5 M40 P1.5

250

241

297

121

180

20

421

103

14.5 M40 x P1.5

312

250

279

335

121

180

20

421

103

14.5 M40 P1.5

400

374

287

305

365

133

200

25

469

88

18.5 M50 P1.5

400

374

287

305

365

133

200

25

469

88

18.5 M50 P1.5

Flange
LA

LE

Fig. 3

Shaft Extension

Bearings

ED

GA

DH

DE

NDE

63

12

76

248

115

95

140

10

11

23

10

8.5

12.5

M4 8

6201ZZ

6201ZZ

71

12

86

278

130

110

160

10

3.5

14

30

14

11

16

M5 10

6202ZZ

6202ZZ
6204ZZ

80

12

92.5

282.5

165

130

200

12

3.5

19

40

25

15.5

21.5

M6 12

6204ZZ

90S

12

101.5

346.5

165

130

200

12

3.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

90L

12

101.5

371.5

165

130

200

12

3.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

100L

16

112

414.5

215

180

250

14.5

28

60

40

24

31

M10 20

6206ZZ

6305ZZ

112M

16

121.5

431.5

215

180

250

14.5

28

60

40

24

31

M10 20

6306ZZ

6306ZZ

132S

20

145

504

265

230

300

14.5

38

80

56

10

33

41

M12 24

6308ZZ

6306ZZ

132M

20

145

542

265

230

300

14.5

38

80

56

10

33

41

M12 24

6308ZZ

6306ZZ

160M

20

180

608

300

250

350

18.5

42

110

80

12

37

45

M16 32

6309ZZ

6307ZZ

160L

20

180

652

300

250

350

18.5

42

110

80

12

37

45

M16 32

6309ZZ

6307ZZ

180MA

20

200

672

300

250

350

18.5

48

110

80

14

42.5

51.5

M16 32

(6211C3)

(6211C3)

180MC

20

200

672

300

250

350

18.5

48

110

80

14

42.5

51.5

M16 32

6311ZZ

6310ZZ

180LC

20

200

710

300

250

350

18.5

48

110

80

14

42.5

51.5

M16 32

6311ZZ

6310ZZ

200LA

20

222

770

350

300

400

18.5

55

110

80

16

49

59

M20 40

(6312C3)

(6212C3)

200LC

20

222

770

350

300

400

18.5

55

160

80

16

49

59

M20 40

6312C3

6313C3

Notes:

1. Tolerance: Refer to page 30.


2. Lifting lugs not provided on frames D90 and smaller.
3. Data subject to change without notice and should not be used for installation purposes.

TECO AUSTRALIA PTY LTD

fifteen

15

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Induction Motors
Frame 225 - 315M Foot and Flange Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 4
Output (kW)

Dimensions (mm)

2P

4P

6P

8P

Frame
Size

AA

AB

AD

AE

BA

BB

HA

HD

HE

37

18.5

225SC

356

90

450

427

330

286

350

149

225

30

524

57

18.5 M50 P1.5

Fig.
No.

KK

45

225MA

356

90

450

427

330

311

375

149

225

30

524

57

18.5 M50 P1.5

45

30

22

225MC

356

90

450

427

330

311

375

149

225

30

524

57

18.5 M50 P1.5

55

250SA

406

100

500

493

375

311

385

168

250

36

575

42

24

M63 P1.5

55

37

30

250SC

406

100

500

493

375

311

385

168

250

36

575

42

24

M63 P1.5

75

250MA

406

100

500

493

375

349

425

168

250

36

575

42

24

M63 P1.5

75

45

37

250MC

406

100

500

493

375

349

425

168

250

36

575

42

24

M63 P1.5

90

280SA

457

110

560

600

445

368

110

445

190

280

30

651

82

24

M63 P1.5

90

55

45

280SC

457

110

560

600

445

368

110

445

190

280

30

651

82

24

M63 P1.5

110

280MA

457

110

560

600

445

419

110

495

190

280

30

651

82

24

M63 P1.5

457

110

560

600

445

419

110

495

190

280

30

651

82

24

M63 P1.5

508

115

615

600

465

406

115

490

216

315

35

723

112

28

M63 P1.5

110

75

55

280MC

132

315SA

132

90

75

315SC

508

115

615

600

465

406

115

490

216

315

35

723

112

28

M63 P1.5

150 / 185

315MA

508

115

615

600

465

457

115

540

216

315

35

723

112

28

M63 P1.5

150

110 / 132

90

315MC

508

115

615

600

465

457

115

540

216

315

35

723

112

28

M63 P1.5

185

315MB

508

115

615

600

465

457

115

540

216

315

35

723

112

28

M63 P1.5

Flange

Shaft Extension

Bearings

Frame
Size

LA

LE

ED

EE

GA

DH

DE

225SC

22

241

816

400

350

450

18.5

60

140

110

18

53

64

M20 40

6313

6213

225MA

22

241

811

400

350

450

18.5

55

110

80

16

49

59

M20 40

6312C3

6212C3

225MC

22

241

841

400

350

450

18.5

60

140

110

18

53

64

M20 40

6313

6213

250SA

22

263.5

882.5

500

450

550

18.5

60

140

110

18

53

64

M20 40

6313C3

6213C3

NDE

250SC

22

263.5

882.5

500

450

550

18.5

70

140

110

20

62.5

74.5

M20 40

NU316

6313

250MA

22

263.5

920.5

500

450

550

18.5

60

140

110

18

53

64

M20 40

6313C3

6213C3

250MC

22

263.5

920.5

500

450

550

18.5

70

140

110

20

62.5

74.5

M20 40

NU316

6313

280SA

22

344

1042

500

450

550

18.5

65

140

110

134

18

58

69

M20 40

6314C3

6314C3

280SC

22

344

1072

500

450

550

18.5

80

170

140

157

22

71

85

M20 40

NU318

6316
6314C3

280MA

22

344

1092

500

450

550

18.5

65

140

110

134

18

58

69

M20 40

6314C3

280MC

22

344

1122

500

450

550

18.5

80

170

140

157

22

71

85

M20 40

NU318

6316

315SA

25

369

1131

600

550

660

24

65

140

110

134

18

58

69

M20 40

6314C3

6314C3

315SC

25

369

1161

600

550

660

24

85

170

140

157

22

76

90

M20 40

NU320

6316

315MA

25

369

1182

600

550

660

24

65

140

110

134

18

58

69

M20 40

6314C3

6314C3

315MC

25

369

1212

600

550

660

24

85

170

140

157

22

76

90

M20 40

NU320

6316

315MB

25

369

1212

600

550

660

24

85

140

140

157

22

76

90

M20 40

NU320

6316

Notes:

16

Fig. 5

1. Tolerance: Refer to page 30.


2. Usable Shaft length: EE
3. Data subject to change without notice and should not be used for installation purposes.

sixteen

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Outline Dimensions Sheet MAX-E2


Teco Cast Iron Tefc 3-Phase Squirrel Induction Motors
Frame 63 - 132 Foot and C Face Mount
Totally Enclosed Fan Cooled Squirrel Cage Rotor

Fig. 1

Output (kW)
2P

4P

6P

8P

Frame
Size

0.18

0.18

63

Fig.
No.

Dimensions (mm)
A

AA

AB

AC

AD

AE

BB

HA

HC

HD

HE

KK

100

28

120

144

123

97

80

100

40

63

135

10

M20 P1.5
M20 P1.5

0.37 / 0.55

0.37

0.18

71

112 35.5 140

162

133

107

90

115

45

71

152

35

0.75 / 1.1

0.55 / 0.75

0.37 / 0.55

0.18

80

125 35.5 155

177

179

130

100

130

50

80

168

13

10 M25 P1.5

140 35.5 170

200

192

143

100

130

56

90

10

190

23

10 M25 P1.5

140 35.5 170

200

192

143

125

150

56

90

10

190

23

10 M25 P1.5
12 M25 P1.5

1.5

1.1

0.75

0.37

90S

2.2

1.5

1.1

0.55

90L

2.2 / 3

1.5

0.75 / 1.1

100L

160

45

195

219

202

153

140

175

63

100 12.5

243

33

2.2

1.5

112M

190

45

224

238

211

162

140

175

70

112

14

265

45

12 M25 P1.5

5.5 / 7.5

5.5

2.2

132S

216

45

250

273

249

187

140

175

89

132

16

310

58

12 M40 P1.5

7.5

4 / 5.5

132M

216

45

250

273

249

187

178

212

89

132

16

310

58

12 M40 P1.5

Flange

Shaft Extension

Bearings

Frame
Size

LE

ED

GA

DH

DE

NDE

63

105

248

75

60

90

M5

11

23

18

8.5

12.5

M4 8

6201ZZ

6201ZZ

71

112

277

85

70

105

M6

3.5

14

30

24

11

16

M5 10

6202ZZ

6202ZZ

80

92

282

100

80

120

M6

3.5

19

40

25

15.5

21.5

M6 12

6204ZZ

6204ZZ

90S

140

346

115

95

140

M8

3.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

90L

140

371

115

95

140

M8

3.5

24

50

32

20

27

M8 16

6205ZZ

6205ZZ

100L

111

374

130

110

160

M8

28

60

40

24

31

M10 20

6206ZZ

6305ZZ

112M

161

431

130

110

160

M8

28

60

40

24

31

M10 20

6306ZZ

6306ZZ

132S

145

454

165

130

200

M10

38

80

64

10

33

41

M12 24

6308ZZ

6306ZZ

132M

145

492

165

130

200

M10

38

80

64

10

33

41

M12 24

6308ZZ

6306ZZ

Notes:

1. Tolerance: Refer to page 30.


2. Lifting lugs not provided on frames D90 and smaller.
3. Data subject to change without notice and should not be used for installation purposes.

TECO AUSTRALIA PTY LTD

seventeen

17

RETURN TO INDEX

Axial / Radial Loadings


The table below gives the permissible axial and radial loads. The values are based on
normal conditions at 50 Hz and a calculated L10 bearing life of 40,000 hours.
Frame
Size

Notes:


Radial Load
Horizontal
Shaft

twenty

Axial Load
Shaft Down
(down thrust)

Axial Load
Shaft Down
(up thrust)

80

47 kg

69 kg

65 kg

73 kg

90

49 kg

73 kg

66.5 kg

79.5 kg

100

72 kg

105 kg

95 kg

115 kg

112

95 kg

138 kg

124 kg

152 kg

132

147 kg

143 kg

123 kg

163 kg

160

179 kg

174 kg

134 kg

214 kg
292 kg

180

248 kg

238 kg

182 kg

200

297 kg

290 kg

210 kg

370 kg

225

305 kg

310 kg

230 kg

390 kg
510 kg

250

1400 kg

325 kg

320 kg

280

1500 kg

315M

1650 kg

1. Based on 4 Pole motors, bearing life L-10 40,000 hours.


2. For radial load overhung point at centre of shaft extension.
3. For other loadings, please contact TECO.

Axial Radial Loadings - Foot

18

Axial Load
Horizontal
Shaft

Axial Radial Loadings - Flange

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Cooling
Designation System Concerning Methods of Cooling Refers to Standard AS1359.106.
Standard Code Example
Code

Description

IC 01

Self-cooling open machine.

IC411

Enclosed machine.
Smooth or finned ventilated casing.
External shaft-mounted fan.

IC416

Enclosed machine.
Smooth or finned ventilated casing.
External motorized axial fan
supplied with machine.

Type

Example
Code

IC

(A)

(A)

International Cooling

Circuit Arrangement

Primary Coolant

0 : Free circulation (open circuit)


4 : Frame surface cooled

A : Air (omitted for simplified designation)

Method of Movement
of Primary Coolant

0 : Free convection
1 : Self-circulation
6 : Machine-mounted independent component

Secondary Coolant

A : Air (omitted for simplified designation)


W : Water

Method of Movement
of Secondary Coolant

0 : Free convection
1 : Self-circulation
6 : Machine-mounted independent component

Cooling air flows from the non-drive-end to the drive end. When the motor is installed care should be
taken not to impede the airflow into the motor fan cover. As a guide the following minimum dimension BL
should be adopted.
Motor
Frame

Dimensions
BL (mm)

80 - 100

60

112 - 132

85

160 - 180

85

200 - 250

110

280

140

315 - 355

180

TECO AUSTRALIA PTY LTD

twenty one

19

RETURN TO INDEX

Force Cooling IC416


TECO can offer force cooling on most TEFC motors, listed below are common sizes with details (larger sizes
please refer to TECO). All force cooling motors are 230 ~ 240 Volts Single Phase 50 Hz and are IP55 as standard.
Fan motor leads are terminated in an auxiliary terminal box mounted on the fan cover.
Frame Size

Notes:

Motor Watts

Amps

Force Cooling Unit


length Lfc in mm
95

D80

17

0.1

D90

29

0.12

95

D100

29

0.12

90
105

D112

46

0.22

D132

46

0.22

85

D160

75

0.42

140

D180

75

0.42

135

D200

135

0.59

95

1. Dimensions subject to change.

Typical Force Cooling Unit.


View from the inside.

Force Cooling Lfc

20

twenty two

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Mounting (IM code)


Mounting Arrangement (IM)
Foot Mounted

Flange Mounted

Foot / Flange Mounted

IM 1001 (IM B3)

IM 3001 (IM B5)

IM 2001 (IM B35)

Horizontal Shaft.
Foot mounted.

Horizontal Shaft.
D type flange at
D.E. No feet.

Horizontal Shaft.
D type flange at
D.E. Foot mounted.

IM 1051 (IM B6)

IM 3011 (IM V1)

IM 2011 (IM V15)

Horizontal Shaft.
Foot wall mounted with
feet on left-side when
viewed from D.E.

Vertical Shaft.
D type flange at D.E.
Shaft down. No feet.

Vertical Shaft.
D type flange at
D.E. Wall mounted.
Shaft down.

IM 1061 (IM B7)

IM 3031 (IM V3)

IM 2031 (IM V36)

Horizontal Shaft.
Foot wall mounted
with feet on right-side
when viewed from D.E.

Vertical Shaft.
D type flange at D.E.
Shaft up. No feet.

Vertical Shaft.
D type flange at
D.E. Wall mounted.
Shaft up.

IM 1071 (IM B8)

IM 3601 (IM B14)

IM 2101 (IM B34)

Horizontal Shaft.
Ceiling mounted with
feet above motor.

Horizontal Shaft.
C type flange at
D.E. No feet.

Horizontal Shaft.
C type flange at
D.E. Foot mounted.

IM 1011 (IM V5)

IM 3611 (IM V18)

IM 2111

Vertical Shaft.
Wall mounted.
Shaft down.

Vertical Shaft.
C type flange at D.E.
Shaft down. No feet.

Vertical Shaft.
C type flange at
D.E. Wall mounted.
Shaft down.

IM 1031 (IM V6)

IM 3631 (IM V19)

IM 2131

Vertical Shaft.
Wall mounted.
Shaft up.

Vertical Shaft.
C type flange at D.E.
Shaft up. No feet.

Vertical Shaft.
C type flange at
D.E. Wall mounted.
Shaft up.

It is important to nominate the IM code at enquiry and order stage to ensure that drain holes are in the correct position
and bearing arrangement is checked for suitability if the IM code differs from standard.

Standard Mounting Arrangement


TECO Stock Motors - Standard Mounting Arrangement and Terminal Box Position
Mounting

IM Code

(IM Code)

Terminal box position


(viewed from drive end)

Cable entry direction

Foot

IM1001

IMB3

Right

From below

Flange

IM3011

IMV1

As needed (motor can be rotated)

From flange end

Foot & Flange

IM2001

IMB35

Right

From below

Mounting - Cast Iron Slide Rails - Dimensions

SLIDE
RAIL

FRAME
SIZE

AL

AT

AU

AX

AY

AZ

BT
min.

XA
max.

XB

XD

XE

XF

M0809

80
90
100
112
132
160
180
200
225
250
280
315

355
355
470
470
470
615
615
780
780
965
965
1215

12
12
16
16
16
19
19
25
25
30
30
40

10
10
12
12
12
15
15
19
19
24
24
38

30
30
44
44
44
64
64
82
82
100
100
125

105
105
170
170
170
170
170
210
210
275
275
380

35
35
52
52
52
76
76
100
100
100
100
123

95
80
160
125
100
155
125
190
140
250
190
330

45
45
50
50
50
67
67
80
80
86
86
110

30
30
43
43
43
57
57
82
82
82
82
95

6
6
6
6
6
11
11
12
12
16
16
20

325
325
430
430
430
565
565
725
725
885
885
1115

15
15
18
18
18
25
25
27
27
40
40
50

M1013

M1618
M2022
M2528
M3100

TECO AUSTRALIA PTY LTD

twenty three

21

RETURN TO INDEX

Protection (IP code)


Protection (IP)
First number: Protection against solid objects
IP

22

twenty four

Tests

Second number: Protection against liquids

Definition

IP

No protection.

No protection.

Protected against
solid objects of
over 50mm
(e.g. accidental
hand contact).

Protected against
vertically dripping
water (condensation).

Protected against
solid objects of
over 12mm
(e.g. finger).

Protected against
water dripping up to
15 from the vertical.

Protected against
solid objects of
over 2.5mm
(e.g. tools, wire).

Protected against rain


falling at up to 60
from the vertical.

Protected against
solid objects of
over 1mm
(e.g. thin wire).

Protected against
water splashes from
all directions.

Protected against
dust (e.g. no deposits
of harmful material).

Protected against
jets of water from
all directions.

Totally protected
against dust.

Protected against
jets of water
comparable to
heavy seas.

Protected against
effects of immersion
to depths of between
0.15 and 1m.

Protected against
the effects of prolonged
immersion at depth.

TECO AUSTRALIA PTY LTD

Tests

Definition

RETURN TO INDEX

Altitude and Ambient Temperature


Rated output power specified in the performance data tables apply for standard ambient conditions of 40C
up to I000 m above se a level. Where temperature or altitude differ from the standard, multiplication factors in
the table below should be used if motor temperature rise is to be maintained.
Ambient
Temperature

Notes:

Temperature
Factor

Altitude
above sea level

Altitude
Factor

30C

1.06

1000 m

35C

1.03

1500 m

0.97
0.945

40C

2000 m

45C

0.97

2500 m

0.92

50C

0.93

3000 m

0.89

55C

0.9

3500 m

0.865

60C

0.865

4000 m

0.835

1. Effective Power = (Rated Power) x (Temperature Factor) x (Altitude Factor)


2. The low temperature rise of TECO motors in many instances preclude the need for derating, please refer to TECO.

Earth Topography

TECO AUSTRALIA PTY LTD

twenty five

23

RETURN TO INDEX

Anti-Condensation Heaters (Optional)


Anti-condensation heaters are used to prevent
the water accumulation caused by moisture
condensation inside the motor. These are flexible
type elements and tied on the ends of the winding
to maintain the average temperature of the motor
above dew point. The heaters must be switched on
when the machine stops and switched off whilst
the machine is in operation. A prominent warning
label is fitted with the appropriate rating of the
heaters nominated.
The space heater leads are normally terminated
to an auxiliary terminal box for safety reasons.
The normal supply of space heaters is single
phase 240V, other voltages can be supplied on
request.

Power Rating of Anti-Condensation Heaters


Heater length varies to suit diameter of end-winding.
Frame
Size

Power in
Watts

80 ~ 100

25

112

21

132 ~ 160

40

180 ~ 200

26

225 ~ 250

42

280

54

315M

99

315A

200

355

250

Connection Diagrams
TECO motors are connected as shown on the
motor nameplate, typical Star or Delta connection
diagram is shown below.
TECO stock motors 4 kW and below are
380 ~ 415 Volt 50 Hz STAR connected and may

also be reconnected to 240 Volt 3-Phase 50 Hz


DELTA configuration for use with single phase
input inverters.
Motors 5.5 kW and larger are 380 ~ 415 Volt
50 Hz DELTA connected.

Duty
TECO motors are supplied suitable for S1
operation (continuous operation under rated load).
When the motor is to operate under any other type
of duty the following information should be supplied
to determine the correct motor size.

24

twenty six

Type and frequency of switching (short time,


intermittent, periodic, high inertia, braking).

Load torque variation during motor


acceleration and braking (in graphical form).
Moment of inertia of the load on the

motor shaft.
Type of braking (e.g. mechanical, electrical

through phase reversal or DC injection.)
For duty cycles other than S1

please refer to TECO.

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Formulae and Conversions


Electric Motor characteristics

Conversions

Output Power
P (kW) = M x n

9550

Length

Output Power
Pmec = 3 x U x I x cos x

1000
Output Torque
M = 9550 x P
n

Efficiency
= Output kW
Input kW
= Pmec x 1000
3 x U x I x cos

I = Pelec x 1000
3 x U x cos

I - Motor current, can be calculated for full or partial
loadings.
Use Efficiency and Power Factor relative to motor
loadings.

Motor Speed
n = 120 x f
Poles

100
0.1

1 ft =

0.3048

30.48

304.8

1 in =

0.254

2.54

25.4

kp

0.102

102

1 kp =

9.807

1000

1 lbf =

4.448

0.4536

453.6

1 in =

0.254

2.54

25.4

km/h

m/min

m/s

1 km/h =

16.667

0.2778

1 m/min =

0.06

16.7 x 10 -


Velocity

1m/s =

3.6

60

1 in =

0.254

2.54

25.4

Nm

kgfm

1 Nm =

0.10197

1 kgfm =

9.8067

1 lbf.ft =

1.356

0.1383

1 lbf.in =

0.1129

11.5 x 10 -

Power
kW

hp

1 kW =

1.341

1 hp =

0.7457

Moment of inertia
kgm (J)

kgfm(GD)

1 kgm (J) =

1 kgfm(GD) =

0.25

Number of Poles - Synchronous Speed


2

10

12

50

3000

1500

1000

750

600

500

60

3600

1800

1200

900

720

600

Subscript
Pel = electrical
P mec = mechanical

1
0.001

Torque

Motor Current
I = Pmec x 1000
3 x U x cos x

P = Power in kW

1000

1m=
1 mm =

1N=

3-Phase Input Power


Pel = 3 x U x I x cos

1000

mm

Force and weight

Current (Star) = Full Load Current (Delta)



0.577

Key:

cm

m = meter, cm - centimeter, mm = millimeter

Star Delta Starting


Torque (Star) = Full Load Torque (Delta)

0.333

Hz

m = Torque in Nm
n = Rotational speed in r/min
U = Line voltage in V
I = Line current in A
cos = Power factor (per unit)
= Motor efficiency (per unit)
f = Frequency in Hz
J = WR 2 = WK 2

TECO AUSTRALIA PTY LTD

twenty seven

25

RETURN TO INDEX

Insulation Classes
The majority of TECO motors comply with a
limitation of Class E temperature rise (75C) or
less thereby providing a minimum of an additional
5C that can be added to the safety margin, which
provides the client with a motor that will perform
extremely well in arduous temperature applications
180
whether this be load or ambient induced.

The graph below indicates the limits of winding


temperature and temperature rise for the various
insulation classes in accordance with AS60034-1
Items 1b) & 1d) AC motors.
The difference between the temperature rise
and the insulation class rating equates to the safety
margin available.

160

180

140

160
Temperature

140
Temperature

120
100
80

120
100
80
60
40

60

20

40

20
0

B
H

Insulation Class

Insulation Class

Max temp rise C


Max winding temp C

Max temp rise C


Max winding temp C

Speed vs. Torque - Current

The graph below indicates the typical speed vs. torque current characteristics of a D132 frame motor to
Design N Normal Torque. The motor is started DOL and the major points on these curves are defined below.

Speed vs. Torque - Current Curves

Speed
SpeedvsvsTorque
Torque- -Current
CurrentCurves
Curves

400
400

Pull
Pullout
outor
or
Breakdown
Breakdowntorque
torque

LockedRotor
Rotoror
or
Locked
StartingCurrent
Current
Starting
300
300
% Full Load Torque
% Full Load Torque

StartingTorque
Torque
Starting

800

Pull out or
Breakdown torque

Locked Rotor or
Starting Current

200
200

600

Locked Rotor or
Starting Torque

Pull-up
Pull-upTorque
Torque

100
100

200

400

00

100

00

20
20

40
40
60
60
Full Load Torque

200

twenty eight

20

40

60

% Synchronous Speed

80

80
80

00
100
100

% Full Load Torque


% Full Load Current

Full Load Current

%%Full
FullLoad
LoadTorque
Torque
FullLoad
LoadCurrent
Current
%%Full

FullLoad
LoadCurrent
Current
Full

%%Synchronous
SynchronousSpeed
Speed

26

200
200

Full
FullLoad
LoadTorque
Torque
Pull-up Torque

% Full Load Current

% Full Load Torque

300

400
400

% Full Load Current


% Full Load Current

600
600

Speed vs
TorqueRotor
-Rotor
Current
Locked
or Curves
Locked
or

400

800
800

0
100

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Starts Per Hour


Starts Per Hour and Maximum Load Inertia
Maximum starts per hour DOL based on maximum load inertia listed, these are quoted as equally spaced
and includes one cold start.
For larger inertias and / or greater frequency of starting please refer to TECO.
Starts Per Hour (Based on Maximum Load Inertia)
Frame Size

Pole

80 - 112

132 - 160

180 - 200

225 - 250

280

12

10

315M
3

22

20

16

10

28

25

20

12

Maximum Allowable Load Inertia


Load Inertia
kW

GD Kg-m

0.75

0.325

0.081

1.41

0.353

3.65

0.913

7.54

1.1

0.440

0.110

2.09

0.523

5.60

1.40

11.0

2.74

0.145

2.68

0.670

7.30

1.83

14.6

3.65

WR Kg-m
2

GD Kg-m
2

2 Pole

WR Kg-m2 GD2 Kg-m2 WR2 Kg-m2 GD2 Kg-m2 WR2 Kg-m2


2

4 Pole

6 Pole

8 Pole
1.89

1.5

0.580

2.2

0.850

0.213

4.14

1.04

10.7

2.68

21.2

5.29

1.12

0.280

5.35

1.34

14.0

3.50

27.9

6.97

1.53

0.383

7.23

1.81

19.0

4.75

38.0

9.51

5.5

2.02

0.505

9.49

2.37

25.3

6.33

50.6

12.7

7.5

2.68

0.670

12.4

3.10

33.3

8.34

66.4

16.6

11

3.89

0.973

18.3

4.57

48.7

12.2

97.3

24.3

15

5.11

1.28

24.1

6.02

63.8

15.9

127

31.8

18.5

6.20

1.55

29.7

7.42

78.8

19.7

157

39.2

22

7.54

1.89

35.1

8.76

93.5

23.4

187

46.8

30

9.73

2.43

46.0

11.5

122

30.5

245

61.2

37

11.9

2.98

56.5

14.1

151

37.8

302

75.5

45

14.1

3.53

66.9

16.7

179

44.8

358

89.5

55

17.3

4.32

82.2

20.6

220

55.0

441

110

75

22.4

5.60

107

26.8

187

46.8

577

144

90

27.5

6.88

132

33.0

353

88.2

710

178

110

32.3

8.08

156

39.0

418

105

132

36.5

9.13

176

44.0

481

120

150

41.8

10.5

202

50.5

185

51.1

12.8

247

61.8

Notes:

* For larger sizes please refer to TECO.

TECO AUSTRALIA PTY LTD

twenty nine

27

RETURN TO INDEX

Thermal Protection
The various types of thermal protection devices are described as below. Whilst these devices provide excellent
thermal protection they may not fully protect against some transient conditions.
Additional set(s) of these protection devices can be provided with a lower temperature rating which can be
utilized as an alarm function. Higher temperature ratings can be supplied for higher trip temperatures, however
care should be taken to ensure the temperature rating of the insulation class is not compromised.

Thermistors
Temperature vs. Resistance Diagram

Thermistors, thermo-variable resistors and have


a positive temperature co-efficient (PTC). Three
thermistors are fitted to the end-windings (one per
phase), which are connected in series. The standard
TECO thermistors have a trip temperature of 160C
@ 1000 ohms (3000 ohms total, 3 thermistors, one
per phase).
Thermistors are sensors that require connection
to a control relay (this relay is not supplied by TECO).
The leads normally are terminated in the main
terminal box with an auxiliary terminal box available
if specified.

Resistance ()

4000
1330
500
250

PTC element
20C
Temperature

TNF
TNF TNF TNF
-20C -5C
+5C

Connection Lead Colour Coding


Trip Temperature (C)
90

Lead Wire Colours


green

green

100

red

red

110

brown

brown

120

grey

grey

130

blue

blue

140

white

blue

150

black

black

160

blue

red

Thermistors and / or RTDs should not be Meggered or tested at a voltage above 2.5 volts.

Typical Thermistor Nameplates

28

thirty

TECO AUSTRALIA PTY LTD

TNF
+20C

RETURN TO INDEX

Resistance Temperature Detectors (RTDs)


An RTD, Resistance Temperature Detector, is a
3 wire RTD circuit
device that provides a change in resistance value in
A (white)
relationship to temperature.
This change is of a linear nature thereby
providing the ability to accurately monitor the motor
operating temperatures when connected to an
appropriate relay.
The most commonly used RTD is the platinum
type which has a nominal resistance of 100ohms
B (red)
@ 0C (PT100) and is of the 3 wire type (other RTD
types available on application).
B (red)
When fitted the RTD leads are terminated to
an auxiliary terminal box (it is recommended that
external wiring to this box be of the screened copper
conductor type to prevent any electromagnetic
interference).
Winding RTDs can be provided within the windings, one per phase or more as required.
Bearing RTDs can be provided if required. The RTD element is located in a stainless steel

metal probe and is mounted within a bearing thermowell.
Table for Platinum Resistance Elements (Resistance in Ohms vs. Temperature) e.g. 19C = 107.40 Ohms
C

100.00

100.39

100.78

101.17

101.56

101.95

102.34

102.73

103.12

103.51

10

103.90

104.29

104.68

105.07

105.46

105.85

106.24

106.63

107.02

107.40

20

107.79

108.18

108.57

108.96

109.35

109.73

110.12

110.51

110.90

111.28

30

111.67

112.06

112.45

112.83

113.22

113.61

113.99

114.38

114.77

115.15

40

115.54

115.93

116.31

116.70

117.08

117.47

117.85

118.24

118.62

119.01
122.86

50

119.40

119.78

120.16

120.55

120.93

121.32

121.70

122.09

122.47

60

123.24

123.62

124.01

124.39

124.77

125.16

125.54

125.92

126.31

126.69

70

127.07

127.45

127.84

128.22

128.60

128.98

129.37

129.75

130.13

130.51

80

130.89

131.27

131.66

132.04

132.42

132.80

133.18

133.56

133.94

134.32

90

134.70

135.08

135.46

135.84

136.22

136.60

136.98

137.36

137.74

138.12

100

138.50

138.88

139.26

139.64

140.02

140.39

140.77

141.15

141.53

141.91

110

142.29

142.66

143.04

143.42

143.80

144.17

144.55

144.93

145.31

145.68

120

146.06

146.44

146.81

147.19

147.57

147.94

148.32

148.70

149.07

149.45

130

149.82

150.20

150.57

150.95

151.33

151.70

152.08

152.45

152.83

153.20

140

153.58

153.95

154.32

154.70

155.07

155.45

155.82

156.19

156.57

156.94

150

157.31

157.69

158.06

158.43

158.81

159.18

159.55

159.93

160.30

160.67

160

161.04

161.42

161.79

162.16

162.53

162.90

163.27

163.65

164.02

164.39

170

164.76

165.13

165.50

165.87

166.24

166.61

166.98

167.35

167.72

168.09

180

168.46

168.83

169.20

169.57

169.94

170.31

170.68

171.05

171.42

171.19

190

172.16

172.53

172.90

173.26

173.63

174.00

174.37

174.74

175.10

175.47

200

175.84

176.21

176.57

176.94

177.31

177.68

178.04

178.41

178.78

179.14

Recommend Temperature Settings for RTDs


Device

Type

Location

Alarm

Trip

RTD

Platinium 100 Ohms @ 0 o C

Winding

140 o C

150 o C

RTD

Platinium 100 Ohms @ 0 o C

DE & NDE Bearing

90 o C

95 o C

TECO AUSTRALIA PTY LTD

thirty one

29

RETURN TO INDEX

Tolerances for Electromechanical Characteristics


AS60034-1 Specifies Standard Tolerances for Electromechanical Characteristics
(Squirrel Cage Induction Motors)
Quantity

Tolerance

Efficiency P <
= 150 kW

-15% (1- )

Efficiency P > 150 kW

-10% (1- )

Power factor (Cos )

-1/6 (1-cos )
min. 0.02, max. 0.07

Slip P < 1 kW

30% of the slip

Slip P >
= 1 kW

20% of the slip

Starting torque

-15%, +25% of the torque

Starting current

+20% of the current

Pull-up torque

-15% of the torque

Break down torque

-10% of the torque


>1.5 full load torque

AS1359.10 Dimensional Tolerances


Flange
Dimension N

Shaft Height
Dimension H
Frame Size

Tolerance

Tolerance (mm)
+0

63 to 250

- 0.5
+0

280 to 450

-1

Shaft
Dimension D.
D
14
19 to 28
32 to 48

30

thirty two

Tolerance
j6
j6
k6

55 to 80

m6

85 to 120

m6

125

m6

Tolerance

110

h7

130 & 180

h7

230 & 250

h7

300

h7

350

h7

450

h7

550

h7

Tolerance (mm)
+ 0.008
- 0.003
+ 0.009
- 0.004
+ 0.018

Tolerance (mm)
+0
- 0.035
+0
- 0.040
+0
- 0.046
+0
- 0.052
+0
- 0.057
+0
- 0.063
+0
- 0.070

+ 0.002
+ 0.030
+ 0.011
+ 0.035
+ 0.013
+ 0.040
+ 0.015

C Face
Dimension N
N

Tolerance

60 to 80

h7

95 & 110

h7

130

h7

TECO AUSTRALIA PTY LTD

Tolerance (mm)
+0
- 0.030
+0
- 0.035
+0
- 0.040

RETURN TO INDEX

Variable Speed Drives (VVVF)


The output of Variable Voltage Variable Frequency (VVVF) Drives is not purely sinusoidal. This causes higher
voltage stresses within the windings and increases the losses, vibration, and noise of the motor. The Loadability
Curve and Maximum Safe Speed are as below, this graph should be used as a guide only. Further consultation
with TECO may be required for arduous critical speed and load duties.
Typical Motor Loadability Curve
Motor Constant Torque region
110

Motor Constant Power region

Continuous operating region for motor fitted with Fan


Forced Cooling

100
90

% Motor Torque

80
70
Continuous operating region for standard motor
60
50
40
30
20
10
0

10

20

30

40

50

60

70

80

90

100

110

120

Frequency Hz

Notes:

1. Installation: to follow the guidelines detailed in AS60034-17:2006 Cage induction motors when fed from converters - Application guide
2. Maximum safe operating speed to follow AS60034-1,Table 17

For variable torque loads (centrifugal pumps and fans) for speeds between 5-50 Hz derating is not normally
required. Outside of this range please check with TECO for motor suitability.
Typical variable and constant torque load curves are shown below.

Speed vs. Torque Curves (assuming load torque @ 100% speed = motor full load torque)
Speed vs. Torque
Curves
(assuming
load torque
@ 100%
= motor
full
load full load
Speed vs.
Torque
Curves (assuming
load
torquespeed
@ 100%
speed
= motor

400

400

200

Load curve Load curve


Variable torque
(fan torque
&
Variable
(fan &
centrifugal centrifugal
pumps)
pumps)

300

% Full Load Torque

% Full Load Torque

300

Motor Speed
Torque
curve
Motor
Speed
Torque curve
under DOL conditions
under DOL conditions

100

200
Load curve Load curve
Constant torque
Constant torque
(conveyors etc)
(conveyors etc)

100

Motor Full Load


Motor Full Load
Torque
Torque

20

20

40

40

60

60

80

80

100

100

120

120

% Synchronous
Speed
% Synchronous
Speed
%Torque
Full Load Torque
% Full Load

TECO AUSTRALIA PTY LTD

thirty three

31

RETURN TO INDEX

Variable Speed Drives (VVVF)

continued

Maximum Safe Operating Speeds (AS60034-1 Table 17)

Note:

Frame Number

2 Pole

4 Pole

6 Pole

<
112

5200

3600

2400

132 ~ 180

4500

2700

2400

200

4500

2300

1800

225 ~ 315

3600

2300

1800

Motors are balanced to 60 Hz speed. If motor operation is above 60 Hz special balance may be required (please refer to TECO).

Motor Synchronous Speed vs. Frequency


Motor Synchronous Speed vs. Frequency
Frequency
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120
(Hz)
2 Pole RPM 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 4800 5100 5400 5700 6000 6300 6600 6900 7200
4 Pole RPM 0 150 300 450 600 750 900 1050 1200 1350 1500 1650 1800 1950 2100 2250 2400 2550 2700 2850 3000 3150 3300 3450 3600
6 Pole RPM 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
8 Pole RPM 0 75 150 225 300 375 450 525 600 675 750 825 900 975 1050 1125 1200 1275 1350 1425 1500 1575 1650 1725 1800

Cage Induction Motors when Fed from Variable Speed Drives


TECO motors follow the guidelines laid down in
AS60034-17: Cage Induction motors when fed from
converters - Application guide.
Certain applications, installations and site condition
may cause some damage to motors if they are not
correctly installed. AS60034-17 has details on
installation of Cage Motors and Variable Speed
Drives.
Supply Systems

500 Volts

On TEFC motors frame size D280 and larger TECO


can offer the option of a rotor groundary brush at
the drive end in order to aid in reducing the effects
of Electro Discharge Machining (EDM) on motor
bearings, which can be prevalent in some cases.
On larger motors, frame size D315 and above, we
recommend the additional option on an insulated
bearing at the non drive end to eliminate shaft
current and also assist in reduction of EDM through
the motor bearings.
Both of these options can also be offered on
smaller motors.

Supply systems in excess of 500 Volts and Open


Drip motors frame size C280 and larger may require
special consideration, please refer to TECO.
TECO Random wound stock motors are built in
accordance to stress Category B per IEC60034-18-41.
The tested capability for PDIV (Partial Discharge
Inception Voltage) for TECO stock motors up to
500Volts
Phase to Ground >
1,843Volts@
rise time of >
0.3us
Phase to Phase >
2,633Volts@

rise time of >
0.3us

Rotor Groundary Brush fitted to D315 frame motor

Typical VSD Ready Large Frame Size Motor

32

thirty four

TECO AUSTRALIA PTY LTD

RETURN TO INDEX

Voltage and Frequency Variations during Operation - AS60034-1


Voltage and Frequency Limits for Motors

For a.c. motors rated for use on a power


supply of fixed frequency supplied from an a.c.
generator (whether local or via a supply network),
combinations of voltage variation and frequency
variation are classified as being either Zone A or
Zone B , in accordance with the figure right.
A machine shall be capable of performing its
primary function continuously within zone A, but
need not comply fully with its performance at
rated voltage and frequency and may exhibit some
deviations. Temperature rises may be higher than
at rated voltage and frequency.
A machine shall be capable of performing its
primary function within zone B, but may exhibit
greater deviations from its performance at rated
Voltage and frequency than in zone A. Temperature
rises may be higher than at rated voltage and
frequency and most likely will be higher than those
in zone A.

Voltage Variation, Effect on Performance


The characteristics of motors will of course vary with a corresponding variation in voltage of 10% around
the nominal value.
An approximation of these variations is given in the table below.
Voltage Variation in %
UN -10%

UN -5%

UN -

UN+5%

Torque curve

0.81

0.9

1.1

UN+10%
1.21

Slip

1.23

1.11

0.91

0.83

Rated current

1.1

1.05

0.98

0.98

Rated efficiency

0.97

0.98

0.98

Rated power factor (cos )

1.03

1.02

0.97

0.94

Starting current

0.9

0.95

1.05

1.1

Nominal temperature rise

1.18

1.05

1.00

1.1

P (Watt) no-load

0.85

0.92

1.12

1.25

Q (reactive V A) no-load

0.81

0.9

1.1

1.21

Other Mains Supply


The TECO Australia 380~415 Volt 3-Phase 50 Hz stock motors up to frame size D315M are also suitable for
re-nameplating to 440 Volt 50 Hz or 400~480 Volt 60 Hz without the need for derating. Performance details are
available on request.
Some world supply systems are given below. Site supply details should be checked to confirm.
World 3-Phase Voltage-Frequency
Country

Voltage

Frequency

Country

Voltage

Frequency

Country

Voltage

Frequency

Taiwan

380

60

Japan

200

50/60

* England

415*

50

60

* Germany

380*

50

Italy

380*

50

Spain

380*

50

Netherlands

380*

50

Australia

415

50

Singapore

400

50

Philippines

460

Malaysia

415

50

India

400

50

Indonesia

380

50

Korea

380

60

Thailand

380

50

Vietnam

380

50

China

380

50

USA

460

60

South Africa

380

50

Hong Kong

346

50

Canada

460 or 565

60

Saudi Arabia

380

50

Note:

* EU are harmonising voltage to 400 Volt 50 Hz

TECO AUSTRALIA PTY LTD

thirty five

33

AUSTRALIA & NEW ZEALAND

Head Office, Sydney

Melbourne

Brisbane

Perth

New Zealand

TECO Australia Pty Ltd

TECO Australia Pty Ltd

TECO Australia Pty Ltd

TECO Australia Pty Ltd

TECO New Zealand Ltd

335-337 Woodpark Road,

16 Longstaff Road,

50 Murdoch Circuit,

28 Belgravia Street,

Unit 3, 477 Great South Road,

Smithfield NSW 2164

Bayswater VIC 3153

Acacia Ridge QLD 4110

Belmont WA 6104

Penrose, Auckland

Tel: 02 9765 8118

Tel: 03 9720 4411

Tel: 07 3373 9600

Tel: 08 9479 4879

Tel: 64 9-526 8480

Fax: 02 9604 9330

Fax: 03 9720 5355

Fax: 07 3373 9699

Fax: 08 9478 3876

Fax: 64 9-526 8484


[email protected]

Distributed by:

www.teco.com.au

[email protected]

The information in this catalogue is subject to change without notice.


DESIGNED AND PRODUCED BY SINNOTT BROS: 9775 1100 in conjuntion with TECO Aust.

TECOCI-032013

You might also like