Exercise Tutorial

Download as pdf or txt
Download as pdf or txt
You are on page 1of 72
At a glance
Powered by AI
The document outlines the steps to configure PROFINET IO system engineering using Siemens STEP7 software. It discusses assigning IP addresses, configuring devices and I/O, defining topology, and testing redundancy.

The steps include: creating a project in STEP7, creating the hardware configuration, assigning IP addresses to devices, inserting I/O devices, defining and assigning device names, copying error OBs, downloading and testing, and configuring topology.

To assign an IP address in STEP7, the user opens the control panel and network connections, selects the network adapter, opens its TCP/IP properties, and assigns the IP address. The address must be unique for the subnet and class (A, B, or C).

Exercise

Siemens AG 2012. All Rights Reserved.

Exercise 1

PROFINET IO System
Engineering with STEP7 V5.5

Siemens AG 2012. All Rights Reserved.

Exercise 1:
PROFINET

1. Create Project in STEP7 V5.5


2. Create HW-Config
3. Assign IP Address on PC and CPU
4. Test the connection with Ping Function
5. Insert IO-Devices from your Training Kit (ET200S,
SCALANCE X)
6. Define and assign Device Names
7. Copy Error OBs
8. Download and test
9. Configure Topology

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
Assign IP-Address

1. Open Control Panel


Network Connection
2. Select Network Adapter
for Online Access
3. Open Up Properties for
TCP/IP Protocol
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 1:
Assign IP-Address

Three Network
Classes:
Class A: 1.0 - 127.0
Subnet: 255.0.0.0

Class B: 128.0-191.255
Subnet: 255.255.0.0

Class C: 192.0223.255.255
Subnet: 255.255.255.0

1. Assign IP-Address for the Network Adapter.


2. Notice to make sure addresses are correct for the sub network, IPAddress needs to be unique!

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
Assign IP-Address

1. Call PG/PC-Interface
2. Assign Network Card

3. OK
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 1:
Assign IP-Address

1. Open Browse Dialog


2. Brose Ethernet Network
3. Identify Device and
assign IP-Address
4. OK

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
Assign IP-Address

1. Assign IP-Address
2. Use Ping for test if
addresses of PC and
PLC are in the same
subnet, feedback must
be Reply from ping
function

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
PROFINET

ag
Dr
&
op
Dr
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 1:
PROFINET

1.

Select Device and


configure IOs according
to the real setup

2.

IO-Address, access from


User program

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
PROFINET

1
1. Double click on Device
2. Define Device Name
3. OK

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
PROFINET

1. Select IO-System or IO-Device


2. Call Assign Device Name Dialog

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
PROFINET

1
3
2

1. Select Device name


2. Select Online Device
3. Assign Name
4. After click Assign Name the
Device receives the Name.

5. IP-Address will be set by the IOController and the connection


will be established automatically
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 1:
PROFINET

Offline configuration
Every device receives a
device name (e.g. sample2) 1
STEP 7 automatically assigns a
IP-Address in the Configuration
Online:
Write the device
name to the device

IO-Controller

Start up:
IO-Controller assigns the
device an IP-address
Siemens AG 2012. All Rights Reserved.
Sector
MAC Adr 1 Industry
MAC
Adr 2

Exercise 1:
PROFINET

Copy
OB82,
OB83,
OB86

Download

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 1:
Topology

1. Right Mouse click on the


PROFINET IO System
2. Call up Topology Editor
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 1:
Topology

1
2

1. Start Network Detection


2. Select Ports
3. Apply Online Detection to your
Offline Configuration
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 1:
Topology

1. Interconnections are
automatically created
2. Online Diagnostic is possible

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise

Exercise 2
Webinterface

Siemens AG 2012. All Rights Reserved.

Exercise 2:
Web function

1. Call up Object Properties of the S7-PLC

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
Web function

1. Activate Web interface

2. Edit User Management

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
Web function

1. Goto Report System


Error

2. Tab Diagnostic
Support
3. Activate Diagnostic
Status DB
4. Generate and download
RSE one more time

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
Web function

Creating DB127 in Report System Error is Mandatory for the Function


Module Information
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
Web function

1. Right Mouse click on


Variable Table
2. Call Object Properties
General Part 2 and
Check Web Server

2
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
Web function

1. Save&Compile of Hardware-Configuration is necessary.


2. Download of Hardware Config

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
Web function

Enter IP address

e.g.: 172.16.0.30

Ethernet

Start Web Browser and Test functionality

Siemens AG 2012. All Rights Reserved.


Industry Sector

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
TIA Portal

1. Create Project in TIA Portal


2. Configure CPU and IO System
3. Insert IO-Devices from your Training Kit (ET200S,
SCALANCE X)
4. Define and assign Device Names
5. Copy Error OBs
6. Download and test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
TIA Portal

1. Create a new Project, click


Create
2. Configure a Device
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

1. Add a new Device


2. Use a CPU
3. Take the CPU which is at your
Training Kit and Add it

Siemens AG 2012. All Rights Reserved. 3


Industry Sector

Exercise 2:
TIA Portal

1. Select Ethernet Port


2. Go to Ethernet addresses
3. Add New Subnet

4. Define IP-Address

2
3
4

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
TIA Portal

1. Change to Network View


2. Select your Remote IO from the
Training Kit
3. Drag&Drop it into your working
area
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

1. Drag Interface of the remote IO


2. Drop it to the Controllers
Interface and release mouse
3. Repeat this step for all IO
Devices
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

1. Select Device
2. Define Device Name
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

3
2

1.

Double click on IO-Device

2.

Configure IOs according to


the real setup

3.

Drag&Drop them to the IOSystem


Siemens AG
2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

1.

Right Mouse click on the PROFINET IO System

2.

Call Assign Device Name dialog

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 2:
TIA Portal

1
2

3
4

1.

Select Device Name

2.

Select Online Interface

3.

Select Device you want to


address

4.

Assign Name
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

1.

Select CPU and Download

2.

Select Network Type

3.

Select Show all devices

4.

Select correct CPU

5.

Load configuration

2
3
4

Siemens AG 2012. All Rights Reserved.


5 Industry Sector

Exercise 2:
TIA Portal

1. Add new block


2. Add OB82, OB83, OB86
3. Download Blocks
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 2:
TIA Portal

1. Open OB 1 and
write a little
program
2. Test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 3:
Fieldbus Integration

1. Integrate IE/PB-Link in your project


2. Configure PROFIBUS Network
3. Download and test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 3:
Fieldbus Integration

1.

Select the Gateway you want to use

2.

Drag and Drop it to your Network View

3.

Connect the Ethernet Port to the IO-Controller

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 3:
Fieldbus Integration

1
3
1.

Select the DP-Slave, Drag and Drop it to


your Network View

2.

Connect the PROFIBUS Port to the Proxy

3.

Set PROFIBUS-Address
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 3:
Fieldbus Integration

1.

Assign
device name
to the Proxy

2.

Download
and test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1. Go Online, read CPU Diagnostic


2. Switch on Online mode in Network and Device view
3. Create Report System Error
4. Activate Web interface
5. Define a Watch table for the Web interface
6. Download and test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1.

Select the PLC you wish to go Online

2.

Select Go online Button

3.

Read Online Information's and Functions

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1&2 Change to Device View


and Network view and
read the diagnostic
Information.

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1.

Select Watch & Force Table and add a Watch table for the
Web interface.

2.

Define variables

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1.

Go to Device View and


select the Controller

2.

Select System
diagnostics

3.

Activate it and configure if


necessary

3
2

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

2
1

1.

Select Web Interface

2.

Activate Web Function for the PLC

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1.

Select Automatic Update

2.

Select at least one language for the Web interface

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
Diagnostic

1.

Select Watch table

2.

Insert it to the Web interface

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
User Defined Webpage

2
1

1.

Select User-defined Web pages

2.

Select Directory and Start page of the user page

3.

Define DB Number start number, HTML Code will be converted into


DBs

4.

Generate the Datablocks

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
User Defined Webpage

1.

Web DBs are created for the Web server


Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 4:
User Defined Webpage

1.

Create Startup OB 100

2.

Call Web Server SFC (WWW)

3.

Define Ctrl DB and Status

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 4:
User Defined Webpage

1.

Download and test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 5:
Diagnostic / Panel

1. Insert the Panel in your Project


2. Insert a Screen or Screenlayout
3. Insert the Diagnostic View in your Screen
4. Test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 5:
Diagnostic / Panel

Possibility 1

1.

Select Panel

2.

Drag and Drop


to your
Network View

3.

Adjust IPSettings if
required

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 5:
Diagnostic / Panel

Possibility 2

4
1

1.

Change to Portal
View

2.

Add new device

3.

Select HMI

4.

Add

5.

Pre-configuration
via Wizard is
possible.

Siemens AG 2012. All Rights Reserved.


Industry Sector

Standard
Panel

Exercise 5:
Diagnostic Standard Panel

2
1.

Select the Panel in Project


view and add a new screen

2.

Select Alarm View

3.

Bring it to your screen


Siemens AG 2012. All Rights Reserved.
Industry Sector

Comfort
Panel

Exercise 5:
Diagnostic for Comfort Panel

1.

Add new screen

2.

Besides Alarm View it is


possible to select System
Diagnostic view (Only available
on Comfort Panel)

3.

Bring it to your comfort panel


screen.

2
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 5:
Diagnostic / Panel

1.

Go to Properties

2.

Activate for Current Alarm States

3.

Activate Diagnosis events

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 5:
Diagnostic / Panel

1.

Select your PLC Tags

2.

You will see them in Details View

3.

Drag & Drop a Variable to your screen, it will become automatically an


IO Field.

4.

The Connection between Panel and PLC is now configured!


Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 5:
Diagnostic / Panel

Connection
between PLC
and Panel is
configured
automatically!

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 5:
Diagnostic / Panel

2
1

1.

Compile the panel application

2.

Download or start simulation for testing

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 6:
PROFINET Redundancy

1. Configure Topology
2. Define MRP-Manager and MRP-Clients
3. Test

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 6:
PROFINET Redundancy
1

1.

Change to topological view

2.

Configure the Port interconnections

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 6:
PROFINET Redundancy

1.

Define one of your


Devices as MRPManager

2.

All the other devices


in the Ring-Network
as MRP-Client

2
Siemens AG 2012. All Rights Reserved.
Industry Sector

Exercise 6:
PROFINET Redundancy

Possibility 1

1.

Possibility 2

Adjust the time behavior


of your IO-Devices in the
Ring that a Watchdog of
200ms is configured!
Reason: MRP (Media
Redundancy Protocol)
max. Reconfiguration time
is 200ms.
If this parameter will not
be changed, the IO-Device
will drop off the network
when Redundancy
switchover occurs!

Siemens AG 2012. All Rights Reserved.


Industry Sector

Exercise 6:
PROFINET Redundancy

1.

Download first!!!

2.

Connect the Ring topology

3.

Test Redundancy

Siemens AG 2012. All Rights Reserved.


Industry Sector

Congratulation, you made it!!

Siemens AG 2012. All Rights Reserved.


Industry Sector

Thank you for your attention!

Bernd Lieberth
Promoter Industrial Communication
South East Asia
I IA AS
60 Mac Pherson Road
Singapore 348615
Phone: +65 6490 6464
Fax: +65 6490 6453
Cellular: +65 9150 2977
E-Mail: [email protected]

Siemens AG 2012. All Rights Reserved.

You might also like