The 23AE23 board records up to 8 analog measured values. It can be configured for the following measurement ranges. The differential inputs are not potentially isolated against the power supply. The internal high resolution allows it to scan all measuring ranges (exception: +-2 V DC (11 bit + sign)) with the same resolution.
The 23AE23 board records up to 8 analog measured values. It can be configured for the following measurement ranges. The differential inputs are not potentially isolated against the power supply. The internal high resolution allows it to scan all measuring ranges (exception: +-2 V DC (11 bit + sign)) with the same resolution.
The 23AE23 board records up to 8 analog measured values. It can be configured for the following measurement ranges. The differential inputs are not potentially isolated against the power supply. The internal high resolution allows it to scan all measuring ranges (exception: +-2 V DC (11 bit + sign)) with the same resolution.
The 23AE23 board records up to 8 analog measured values. It can be configured for the following measurement ranges. The differential inputs are not potentially isolated against the power supply. The internal high resolution allows it to scan all measuring ranges (exception: +-2 V DC (11 bit + sign)) with the same resolution.
Doc-No.: 1KGT 150 573 V004 1 1 Analog Input 23AE23
Application The 23AE23 board records up to 8 analog meas- ured values. The 23AE23 board allows connection of all typical measured value ranges. It can be configured for the following measure- ment ranges by setting switches and jumpers: 2 mA 5 mA 10 mA 20 mA 40 mA 2 V DC 0 ... + 20 V DC Other effective ranges and live zero signals be- come generated out of these ranges through con- version of the communication unit (CMU).
Characteristics Basic checks and computing intensive, cyclical processing functions will already be done on the board and remove therefore the burden from the central unit. Relevant changes transmits the board as event via the peripheral bus. The 8 differential inputs are not potentially isolated against the RTU560 power supply. Unipolar or bipolar values resolves the 23AE23 into 4096 steps (12 bit plus sign) for 100 % of the measuring signal. The differential inputs are protected against static and dynamic over-voltages by a protection circuit. A low-pass filter suppresses non line frequency ac disturbance.
The AD-converter, operating with the sigma-delta method scans with a higher resolution and has additional algorithms for a high suppression of line frequency and line harmonics interference voltag- es. Even for a deviation of 10 % of the line fre- quency there is still given a suppression of > 45 dB. The internal high resolution allows it to scan all measuring ranges (exception: 2 V DC (11 bit +sign)) with the same resolution (12 bit + sign) on one board. A 9th channel is used for automatic zero calibration.
Fig. 1: Block diagram Analog input board 23AE23 The analog input board 23AE23 can carry out the following processing functions on the measured values: Zero point monitoring Switch-over recognition Smoothing Threshold value monitoring on absolute val- ue or with accumulation and periodic back- ground transmission. Measuring range and line frequency are easily to configure by switch registers respectively jumpers. EA11 EA10 EA80 + EA81 A/D-converter Multiplexer Connection: A D Input circuit Input circuit B
U
S
M
O
D
U
L
E - - + P r o t e c t i o n
c i r c u i t R e s i s t o r
n e t w o r k EA11 EA10 EA80 + EA81 A/D-converter Multiplexer Connection: A D Input circuit Input circuit B
U
S
M
O
D
U
L
E - - + P r o t e c t i o n
c i r c u i t R e s i s t o r
n e t w o r k RTU560
Data Sheet Analog Input 23AE23
2 Doc.No.: 1KGT 150 573 V004 1 The micro controller needs these configurations parameters to setup the AD-converter.
Line frequency [Hz] Conversion period per channel [ms] Scan cycle per board [ms] 60 50 16,6 62,5 72,5 202,5 500 580 1620 The micro controller controls the A/D converter and executes all of the processing functions of the configured measured values within the conversion time. Furthermore the micro controller is respon- sible for interactive communication with the RTU560 system bus. All configuration characteris- tics and processing parameters are downloaded from the CMU via the RTU system bus. During initialization and operation the board car- ries out a number of tests. If a fault occurs it is re- ported to the CMU. All fault conditions impairing the function of the board are displayed as com- mon fault signal with a light emitting diode (ST) on the front panel. A failure of the board is detected by the CMU. The board has a serial connection to the RTU560 peripheral bus. It cant be used in a basic subrack of a RTU232 (parallel bus).
RTU560
Data Sheet Analog Input 23AE23
Doc.-No. 1KGT 150 573 V004 1 3 Technical Data In addition to the RTU560 general technical data, the following applies: Input channels Inputs 8 differential inputs Measuring ranges 2 mA 5 mA 10 mA 20 mA 40 mA 2 V DC / 0 20 V DC Shunt / impedance 50 at 40 and 20 mA 150 at 10 to 2 mA 110 k at 2 V and 20 V DC Continuous load without destruction max. 80 mA for ranges 40 and 20 mA, max. 40 mA for ranges 10/5 to 2 mA, max. 38 V / max. 0.5 mA for ranges 2 and 20 V DC AD converter resolution: 24 bit Resolution: 12 bit + sign = 100%, all ranges except 2 V DC: 11 bit + sign for 2 V DC Common mode voltage Function limit typ. 8 V DC Absolute maximum rating 150 V DC. Common mode rejection at 0 ... 50 Hz > 70 dB at +25 C > 60 dB at 0 ... +25C Line frequency interference suppression > 100 dB for f N 2% > 45 dB for f N 10% Line frequency (f N ): 16.6, 50 or 60 Hz Error on delivery: 0.1 % 0.2 % for 2 V DC Linearity error: 0.1 % Temperature drift: 100 ppm/K (0...70 C) Power Supply Supply: 5V / 190 mA Mechanical Layout Printed circuit board 3HE, Euro-card format (160 x 100 mm) Front panel: 4R, 1 slot (20 mm) Weight: approx. 0.3 kg Connection Type Connector: indirect 48 pole, F DIN 41612 Electromagnetic Compatibility Electrostatic dis- charge Immunity IEC 61000-4-2 (level 3) 6 kV Contact 8 kV Air
Performance criteria A Radiated Radio- Frequency Electro- magnetic Field Im- munity Test IEC 61000-4-3 (level 3) 10 V/m
Performance criteria A Immunity to Electri- cal Fast Transient IEC 61000-4-4 (level 3) 2 kV
Performance criteria A Surge Immunity Test IEC 61000-4-5 (level 3) 2 kV
Performance criteria A Immunity to Con- ducted Disturb- ances, induced by Radio-Frequency IEC 61000-4-6 (level 3) 10 V
Performance criteria A Environmental Conditions Temperature: -10 ... 70 C Relative humidity: 5 ... 95 % (non condensing) RTU560
Data Sheet Analog Input 23AE23
4 Doc.No.: 1KGT 150 573 V004 1 Ordering Information Front plate: Plastic light beige 23AE23 R5001 1KGT 012 200 R5001
Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB AG.