0 1 2 3 4
Mechanically linked N.C. auxiliary contacts Front-mounted auxiliary contacts Gold bifurcated Permanently fixed Protective cover to prevent manual operation Red contact housing foreasy identification Incorporates IEC 60947-5-1 Mechanically Linked symbol AC and DC operating coils SUVA Third-Party certification
Standards Compliance
EN50205 CSA C22.2 No. 14 UL 508 EN/IEC 60947-4 IEC 60947-4-1 Annex H Mirror Contacts IEC 60947-5-1 Annex L Mechanically Linked Contacts Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS
Bulletin 100S-C/104S-C safety contactors provide mechanically linked positively guided contacts, required in feedback circuits of modern safety applications. The mechanically linked N.C. auxiliary contacts will not change state when a power pole welds. In addition, the gold-plated bifurcated auxiliary contacts are ideally suited for low-energy applications or feedback control circuits with multiple series-connected N.C. auxiliary contacts. Certifications Your order must include: cat. no. of the contactor specified with coil SUVA Third-Party Certified voltage code and, if required, cat. no. of any accessories and/or CE Marked replacement coils.
5
Ie [A]
Aux. Contacts
3-Phase kW (50 Hz) 400V/ 415V 4 5.5 7.5 11 15 18.5/20 22 32 40 45 55 1-Phase 500V 4 5.5 7.5 13 15 20 25 37 45 55 55 690V 4 5.5 7.5 10 15 18.5 22 32 40 45 55 115V 1/2 1/2 1 2 2 3 3 5 5 7-1/2 10 230V 1-1/2 2 3 3 5 5 7-1/2 10 15 15 15
Hp (60 Hz) 3-Phase 200V 2 3 5 5 7-1/2 10 10 15 20 25 30 230V 2 3 5 7-1/2 10 10 15 20 25 30 30 460V 5 7-1/2 10 15 20 25 30 40 50 60 75 575V 7-1/2 10 15 15 25 30 30 50 60 60 75 N.O. 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 N.C. 5 4 5 4 5 4 5 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Cat. No.1 100S-C0905BC 100S-C0914BC 100S-C1205BC 100S-C1214BC 100S-C1605BC 100S-C1614BC 100S-C2305BC 100S-C2314BC 100S-C3004BC
100S-C3014BC
6 7 8 9
AC-3 9 12 16 23 30 37 43 60
100S-C3704BC
100S-C3714BC
100S-C4304BC
100S-C4314BC
100S-C6004BC
100S-C6014BC
10 11 12 13
72 85 97
100S-C7204BC
100S-C7214BC
100S-C8504BC
100S-C8514BC 100S-C9704BC 100S-C9714BC
1 For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100SC0905BC becomes Cat. No. 100S-C0905C. Bifurcated front-mount auxiliary contacts on Cat. Nos. 100S-C60C97 conform to mirror contact performance only. Coil voltage code and terminal positionsee page 2-137 Cat. No. 100S-C0905C Line Side Cat. No. 100S-C09U05C Load Side
www.ab.com/catalogs
2-134
Publication A117-CA001A-EN-P
Bulletin 100S-C/104S-C
0 1
AC-3 9 12 16 23
AC-1 32 32 32 32
1-Phase 500V 4 5.5 7.5 13 690V 4 5.5 7.5 10 115V 1/2 1/2 1 2 230V 1-1/2 2 3 3 200V 2 3 5 5
3-Phase 230V 2 3 5 7-1/2 460V 5 7-1/2 10 15 575V 7-1/2 10 15 15 N.O. 4 3 4 3 4 3 4 3 N.C. 0 1 0 1 0 1 0 1 N.O. 0 0 0 0 0 0 0 0 N.C. 4 4 4 4 4 4 4 4 Cat. No.1 100S-C09404BC 100S-C09304BC 100S-C12404BC 100S-C12304BC 100S-C16404BC 100S-C16304BC 100S-C23404BC 100S-C23304BC
2 3 4 5 6 7 8 9 10 11 12 13
1 For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
Three-phase ratings only apply to contactors with at least three N.O. power poles. If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100SC09404BC becomes Cat. No. 100S-C09404C. Coil voltage code and terminal positionsee page 2-137
www.ab.com/catalogs
Publication A117-CA001A-EN-P
2-135
Bulletin 100S-C/104S-C
0 1 2 3 4 5 6
Not available on 100S/104S-C97 contactors. [V] AC, 50 Hz AC, 60 Hz AC, 50/60 Hz 230 KF 230240 VA 240 T A KA 277 T 347 I 380 E 380400 N 400 KN 4872 EY 400415 G 440 B N KB 480 B 500 M 550 C 600 C
[V] Standard 100S-C09C43 with Integrated Diode Electronic with Integrated Diode 100S-C60C97 with Integrated Diode DC
9 ZR DR
12 ZQ EQ DQ
24 ZJ DJ EJ DJ
36 ZW DW
48 ZY DY
60 ZZ DZ
64 ZB DB
72 ZG DG
80 ZE DE
Assignment of Contacts Safety Contactors with 3 Main Contacts and Standard Front-Mount Auxiliary Contacts
51 61 71 81 51 61 71 81 53 61 71 83
52 62 72 82 A1 K1 A2 2 4 6 22 1 3 5 21 K1 A2 A1
52 62 72 82 1 3 5 13 K1 2 4 6 14 A2 A1
54 62 72 84 1 3 5 21
7 8 9
13
22
100S-C0905CC2305C
100S-C0914CC2314C
100S-C0923CC2323C
11 21 31 41
13 21 31 43
11 21 31 41
12 22 32 42 A1 K1 A2 2 4 6 1 3 5 K1 A2 A1
14 22 32 44 1 3 5 K1 2 4 6 A2 A1
12 22 32 42 1 3 5
10 11 12 13
14
100S-C3004CC9704C
100S-C3022CC9722C
100S-C3014CC9714C
www.ab.com/catalogs
Publication A117-CA001A-EN-P
2-137