Kontakt or I
Kontakt or I
Kontakt or I
Motor-Starters
D677E121
Index
Page
General
Approvals
Technical Information
Mounting Information
2
3
5
6
Mini Contactors
Mini Contactors
Interface Contactors
Mini Reversing Contactors
Technical Information
Dimensions
7
8
8
14
15
20
Contactor Relays
Contactor Relays
Technical Information
Dimensions
21
22
24
26
Contactors
Contactors Overview
Contactors, 3-pole
Contactors, 4-pole
Capacitor Switching Contactors
Accessories
Technical Information
Dimensions
27
28
30
32
33
34
43
64
Star-Delta Starters
Reversing Contactors
Pole Changing Starters
Technical Information
Dimensions
73
74
78
80
82
89
Starters
D.O.L. Starters
D.O.L. Starters
Enclosures
Accessories
Technical Information
Dimensions
93
94
95
95
96
98
Overload Relays
Thermal Overload Relays
Accessories
Technical Information
Dimensions
101
102
103
106
111
Modular Contactors
Contactors
Accessories
Technical Information
Dimensions
115
116
117
118
122
122
125
02 2012
General
Test Authorities, Registration Mark, Approvals
CE-Marking
The manufacturer has to sign his products with the CE-Marking. With the
CE-Marking the manufacturer confirms the accordance with the different
EEC Directives. The CE-Marking is absolutely necessary to sell the
products in the EEC.
Below you find the EEC Directives concerning our products.
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS + WEEE 2002/95/EC + "002/96/EC
Country
North America
Switzerland
Russia
China
UL
Canada, USA
SEV
GOST
CCC
all switchgear
all switchgear
all switchgear
Label marking
of examination boards
Listed
Component
Duty of approvals
all switchgear
Explanations for choice and supply of low voltage switchgear in Canada and USA
Marking of auxiliary contacts
At several devices in UL-data are two voltages for auxiliary contacts
mentioned (e. g.: 600 volts at same potential, 150 volts at different
potentials). That means, if the voltage is higher than 150 volts, the control
voltage applied to input terminals must be at the same potential.
Marking of
auxiliary contacts
according to
CSA and UL
Cont.
Current
A
Contact
Rating
Code
Designation
Heavy Duty
(HD or HVY DTY)
AC 120
AC 240
AC 480
AC 600
60
30
15
12
6
3
1,5
1,2
10
10
10
10
A150
A300
A600
A600
DC 125
DC 250
DC 600
2,2
1,1
0,4
2,2
1,1
0,4
10
10
10
N150
N300
N600
AC 120
AC 240
AC 480
AC 600
30
15
7,5
6
3
1,5
0,75
0,6
5
5
5
5
B150
B300
B600
B600
DC 125
DC 250
DC 600
1,1
0,55
0,2
1,1
0,55
0,2
5
5
5
P150
P300
P600
AC 120
AC 240
AC 480
AC 600
15
7,5
3,75
3
1,5
0,75
0,375
0,3
2,5
2,5
2,5
2,5
C150
C300
C600
C600
DC 125
DC 250
DC 600
0,55
0,27
0,1
0,55
0,27
0,1
2,5
2,5
2,5
Q150
Q300
Q600
AC 120
AC 240
3,6
1,8
0,6
0,3
1
1
D150
D300
DC 125
DC 250
0,22
0,11
0,22
0,11
1
1
R150
R300
AC 120
1,8
0,3
0,5
E150
Standard Duty
(SD or STD DTY)
Low voltage switchgear for auxiliary circuits (e. g. contactor relays, control
units, auxiliary contacts in general) usually approved for "Heavy Duty" or
"Standard Duty" UL and besides these marked with the admissible max.
voltage or with short codes (see table).
Discernment at UL-Standards
Recognized Component
Industrial Control Equipment
Listed
Industrial Control Equipment
Valid UL-Standards:
UL 508 "Standard for Industrial
Control Equipment"
(partly limited)
Valid UL-Standards:
UL 508 "Standard for Industrial Control
Equipment" (unlimited)
D677E
Approvals
Country
North America
Switzerland
UL
SEV
Europe
Russia
GOST
China
CENELEC
CB-Certificates
Type
Mini Contactors, Reversing Contactors K1 and Accessories
K1-07D..(=)
K1-07L..(=)
K1-07F..(=)
o
-
o
o
o
o
o
o
o
-
o
o
-
K1-09D..(=)
K1-09L..(=)
K1-09F..(=)
o
-
o
o
o
o
o
o
o
-
o
o
o
o
o
-
K1-12D..(=)
K1W09D01(=)
K1W12D01(=)
K1W09L01(=)
o
o
-
o
o
o
o
o
o
HK.., HKM..
RC-K1
o
o
o
o
o
-
o
o
o
o
KG3-07..
Contactors Series K3
K3-10N..(=)
K3-14N..(=)
K3-18N..(=)
K3-22N..(=)
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
K3-24A..(=)
K3-32A..(=)
K3-40A..(=)
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
K3-50A..(=)
K3-62A..(=)
K3-74A..(=)
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
K3-90A..(=)
K3-115A..(=)
o
o
o
o
o
o
K3-151A..(=)
K3-176A..(=)
o
o
o
o
K3-210A..(=)
K3-260A..(=)
K3-316A..(=)
x
x
x
o
o
o
K3-450A..(=)
K3-550A..(=)
o
o
o
o
K3-700A..(=)
K3-860A..(=)
K3-1000A..(=)
K3-1200A..(=)
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
K3-50K..
K3-62K..
K3-74K..
K3-90K..
K3-115K..
o
o
o
o
o
o
o
o
o
o
o
o
o
-
o
o
o
o
o
o
o
o
-
HN.., HTN..
HA..
HB..
K2-DK, K2-SK
o
o
o
o
o
o
o
o
o
o
o
-
o
o
-
o
o
o
-
HKA.., HKT..
HKF22
o
-
o
o
Aux. contacts
D677E
x In test
Approvals
Country
North America
Switzerland
UL
SEV
Europe
Russia
GOST
China
CENELEC
CB-Certificates
Type
Accessories
K2-T..E, -A
K2-TP
K2-L
o
o
o
o
o
K2-IN.
K2-UN.
o
o
o
o
K2-IM
K2-E
VG-K2
o
-
o
o
o
RC-K3
o
o
o
o
o
o
o
o
KW3-24
KW3-32
KW3-40
o
o
o
o
o
o
D.O.L. Starters
P1..
o
o
o
o
o
o
o
o
o
o
o
o
U12/16E
U12/16A
U12/16EM
U12/16EQ
o
-
o
o
o
o
o
o
o
o
o
o
o
o
U32
U60
U85
o
o
o
o
o
o
o
o
o
o
o
o
U180
U320
x
x
o
o
U840
U1250
o
o
Modular Contactors
R20
R25
R40
R63
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
K1R
RH11
o
o
o
o
o
o
- and
x In test
Guide-No.
File-No.
Kanada
USA
Kanada
USA
Contactors
Reversing Contactors
Control Relays, Accessories
NLDX7
NLDX7
NKCR7
NLDX
NLDX
NKCR
NLDX8
NKCR8
NLDX2
NKCR2
E41502
E41502
E66273
NKCR7
NLRV7
NLRV7
NKCR
NLRV
NLRV
E66273
NKJH7
NLRV7
NKCR7
NKJH
NLRV
NKCR
E197641
E129916
E66273
E129916
D677E
Technical Information
Degree of protection acc. to IEC 60947-1
Protection ratings are prefixed by the internationally agreed letters IP
followed by two digits.
2 nd
digit
Short description
Definition
1 st digit:
2 nd digit:
Protected against
dripping water
Protected against
dripping water
when tilted
up to 15
Protected against
spraying water
Protected against
splashing water
Protected against
water jets
Protected against
heavy seas
Protected against
the effects of
immersion
Protected against
submersion
No ingress of water.
1 st
digit
Short description
Definition
Protected against
solid objects
greater than 50 mm
2L
Protected against
solid objects
greater than
12,5 mm and
against contact by
standard test finger
Protected against
solid objects
greater than 2,5mm
Protected against
solid objects
greater than 1 mm
Dust protected
Dust tight
Sequence number
Function number
D677E
Technical Information
Mounting positions of contactors
K1-..
K3-151.. to K3-1200..
Terminal screws
Devices
Type
Kind of connection
Screw with
Screw with
washer
clamp box
Screw
w. nut
Screw driver
Tightening torque
Nm
lb. inch
K1-..
M3,5
Pz2
0,8 - 1,4
7 - 12
M3,5
Pz2
0,8 - 1,4
7 - 12
K(G)3-10.. to K3-22..
K(G)3-24.. to K3-40..
K3-50.. to K3-74..
M3,5
-
M5
M6
Pz2
Pz2
Pz3
0,8 - 1,4
2,5 - 3
3,5 - 4,5
7 - 12
22 - 26
31 - 40
K3-90, K3-115
M8
4 - 6,5
35 - 57
K3-116.. to K3-176..
K3-210.. to K3-316..
K3-450.. to K3-700..
M8
M10
M12
17
35
60
150
315
540
K3-860..
K3-1000.., K3-1200..
M14
M12
75
60
675
540
Auxiliary conductor
K(G)3-10 to K3-22
M3,5
Pz2
0,8 - 1,4
7 - 12
Coil conductor
K(G)3-10 to K3-1200
M3,5
Pz2
0,8 - 1,4
7 - 12
M3,5
M3,5
Pz2
Pz2
0,8 - 1,4
0,8 - 1,4
7 - 12
7 - 12
U12/16
M4
Pz2
1,2 - 1,8
11 - 16
U3/32
U3/42
U3/74
M3,5
M5
-
M6
Pz2
Pz2
Pz3
0,8 - 1,4
2,5 - 3
3,5 - 4,5
7 - 12
22 - 26
31 - 40
UAT21
UAT22
UAT23
M4
M4
M5
Size 3, 4
Size 3, 4
Size 3, 4, 5
1,2 - 1,8
1,2 - 1,8
2,5 - 3
11 - 16
11 - 16
22 - 26
Auxiliary conductor
All devices
M3,5
Pz2
0,8 - 1,4
7 - 12
K(G)3-07..
Contactors
Main conductor
Accessories
HK, HKM
HA, HN, K2-.., HB..
Thermal Overload Relays
Main conductor
M3,5
M3,5
M5
-
Pz1
Pz2
Pz2
0,8 - 1,4
2,5 - 3
0,8 - 1,4
7 - 12
22 - 26
7 - 12
Coil conductor
R20, R25
R40, R63
K1R
M3,5
M3
M3
-
Pz1
Pz2
Pz2
0,6 - 1,2
0,6 - 1,2
0,8 - 1,4
5 - 11
5 - 11
7 - 12
D677E
Mini Contactors
D677E
Mini Contactors
Auxiliary Contact Blocks
10
12
12
Coil voltages
12
14
Technical Data
16
Dimensions
20
AC Operated
Ratings
Therm. Contacts 2)
Distinc.
Number
AC15
Rated
Current
Ith
A
NO NC
230V
A
400V
A
Type
Additional
Contact
acc. to
Blocks
EN50011 Type
24
230
24VS
230VS
24VM
230VM
Coil voltage 1)
24V 50/60Hz
220-230V 50Hz
24V 50/60Hz w. protection 3)
220-230V 50Hz w. protection 3)
24V 50/60Hz 24V= DC
220-240V 50/60Hz 220V= DC
Pack Weight
pcs. kg/pc.
10
40E
1 HK..
K1-07D40 . . .
10
0,16
10
31E
1 HK..
K1-07D31 . . .
10
0,16
10
22E
1 HK..
K1-07D22 . . .
10
0,16
Thermal
Rated
Current
A
Contacts 2)
NO
NC
Type
Pack Weight
pcs. kg/pc.
3
3
3
2
2
2
10
10
10
1
2
1
2
-
HK11
HK02
HK20
10
10
10
0,04
0,04
0,04
3
3
3
2
2
2
10
10
10
4
2
-
2
4
HK40
HK22
HK04
10
10
10
0,04
0,04
0,04
HK11
HK02
HK20
HK40
HK22
HK04
42E
33Y
24Y
60E
51Y
42Y
80E
71Y
62Y
62E
53Y
44Y
44E
35Y
26Y
Wiring Diagrams
51E
42Y
33Y
D677E
DC Solenoid Operated
Type
Coil voltage 1)
24V= DC
24
24VS 24V= DC with
protection 2)
Contacts 2)
Distinc.
Number
acc. to
NO NC EN50011
Additional
Contact
Blocks
Type
Pack
pcs.
Weight
kg/pc.
Wiring Diagrams
40E
1 HK..
10
0,19
K1-07D31= ...
31E
1 HK..
10
0,19
K1-07D22= ...
22E
1 HK..
10
0,19
10
0,20
K1-07D31= 24VR
10
0,20
K1-07D22= 24VR
10
0,20
3)
D677E
Mini Contactors
AC Operated
Power Ratings
Rated
Current
AC2, AC3
380V
400V
660V
415V
690V
kW
kW
AC1
690V
A
Aux. Contacts2)
Built-in Additional
NO NC
Coil voltage 1)
24
24V 50/60Hz
230
220-230V 50Hz
24VS 24V 50/60Hz w. protection 3)
230VS 220-230V 50Hz w. protection 3)
24VM 24V 50/60Hz 24V= DC
230VM 220-240V 50/60Hz 220V= DC
Pack Weight
W
pcs.
kg/pc.
Type
Type
4
5,5
20
20
1
1
1 HKM..
1 HKM..
K1-09D10 . . .
K1-12D10 . . .
10
10
0,16
0,16
4
5,5
4
5,5
20
20
1
1
1HK..
1HK..
K1-09D01 . . .
K1-12D01 . . .
10
10
0,16
0,16
1HK..
1HK..
K1-09D00-40 . . .
K1-12D00-40 . . .
10
10
0,16
0,16
4
5,5
20
20
400V
A
Thermal
Rated
Current
A
2
2
2
HKM11
10
10
10
Contacts 2)
Type
Pack
pcs.
NO NC
1
2
HKM11
HKM02
HKM22
1
2
2
Weight
kg/pc.
10
10
10
0,04
0,04
0,04
HKM02
HKM22
HK11
HK02
HK40
HK22
12
32
12
11
03
02
41
40
23
22
Wiring Diagrams
Voltage Range
V
12 - 48V AC/DC
48 - 127V AC/DC
110 - 250V AC/DC
1600nF / 22 Ohm
680nF / 270 Ohm
220nF / 2200 Ohm
Pack
pcs.
RC-K1 24
RC-K1 110
RC-K1 230
10
10
10
D677E
Weight
kg/pc.
0,01
0,01
0,01
DC Solenoid Operated
Type
Coil voltage 1)
24V= DC
24
24VS 24V= DC with
protection 3)
Aux. Contacts 2)
Additional
Built
Additional Overload
in
Relay
see
page102
NO NC
Type
Pack
pcs.
Weight
kg/pc.
Wiring Diagrams
1
1
1 HKM..
1 HKM..
U12/16..K1
U12/16..K1
10
10
0,19
0,19
K1-09D01= . . .
K1-12D01= . . .
1
1
1 HK..
1 HK..
U12/16..K1
U12/16..K1
10
10
0,19
0,19
U12/16..K1
U12/16..K1
10
10
0,19
0,19
U12/16..K1
10
0,20
K1-09D01= 24VR -
U12/16..K1
10
0,20
3)
11
Mini Contactors
AC Operated
Power Ratings
Rated
Current
AC2, AC3
380V
400V
660V
415V
690V
kW
kW
AC1
690V
A
Aux. Contacts2)
Built
Additional
in
NO NC
Type
Type
Coil voltage 1)
24
24V 50/60Hz
230
220-230V 50Hz
24VS 24V 50/60Hz w. protection 2)
230VS 220-230V 50Hz w. protection 2)
24VM 24V 50/60Hz 24V DC
230VM 220-240V 50/60Hz 220V DC
Pack Weight
W
pcs.
kg/pc.
16
1 HKM..
K1-09F10 . . .
10
0,16
16
1 HK..
K1-09F01 . . .
10
0,16
16
K1-09L10 . . .
10
0,16
16
K1-09L01 . . .
10
0,16
10
0,16
16
K1-09L00-40 . . .
Suffix
to
contactor
type
e.g.
K1-09D10 230
Voltage Marking
at the coil
for
for
50Hz
60Hz
V
V
range
for 50Hz
min.
max.
V
V
Voltage Marking
at the coil
for
for
50Hz
60Hz
V
V
range
for 50Hz
min.
max.
V
V
12
24
42
48
12
24
42
48
90
95
100
100
95-100
100
100
105-110
110-115
105
110
180
105-110
110-115
200
115-120
120-125
200
11
22
38,5
48
for 60Hz
min.
max.
V
V
12
24
42
50
12
24
42
48
12
24
42
52
200
210
220
230
200
205-215
210-220
220-230
200-220
220-230
220-240
230-250
195
205
210
220
205
215
220
230
200
220
220
230
220
230
240
250
90
95
100
100
100
105
100
105
110
105
110
115
105
110
185
110
115
200
115
120
200
120
125
210
240
400
500
550
230-240
380-400
475-500
525-550
400-440
520-545
600
230
380
475
525
240
400
500
550
250
400
520
570
260
440
545
600
for 60Hz
min.
max.
V
V
D677E
DC Solenoid Operated
Type
Coil voltage 1)
24V= DC
24
24VS 24V= DC with
protection 3)
Aux. Contacts 2)
Additional
Built
Additional Overload
in
Relay
see
page102
NO NC
Type
Pack
pcs.
Weight
kg/pc.
Wiring Diagrams
1 HKM..
U12/16..K1
10
0,19
K1-09F01= . . .
1 HK..
U12/16..K1
10
0,19
10
0,19
K1-09L01= . . .
10
0,19
10
0,19
13
AC1
Aux. Contacts2)
Built-in Additional
on left
on right
hand side hand side
Contactor Contactor
690V
A
NO NC
AC Operated
K1
Type
K2
Type
Type
Coil voltage 1)
24V 50/60Hz
220-230V 50Hz
24V 50/60Hz w. protection 3)
220-230V 50Hz w. prot. 3)
24V 50/60Hz 24V DC
220-240V 50/60Hz 220V DC
Pack Weight
pcs.
kg/pc.
24
230
24VS
230VS
24VM
230VM
4
5,5
20
20
1
1
HKM11V
HKM11V
HKM11X
HKM11X
K1W09D01MC . . .
K1W12D01MC . . .
1
1
0,32
0,32
4
5,5
4
5,5
20
20
1
1
HKM..
HKM..
K1W09D10MC . . .
K1W12D10MC . . .
1
1
0,32
0,32
HKM..
HKM..
K1W09D00-40MC . .
K1W12D00-40MC . .
1
1
0,32
0,32
4
5,5
20
20
16
K1W09L01MC . . .
0,32
16
K1W09L10MC . . .
0,32
Pack
pcs.
Weight
kg/pc.
400V
A
2
2
Thermal
Rated
Current
A
10
10
HKM11V
Contacts 2)
Type
NO NC
1
1
1
1
HKM11V
HKM11X
10
10
0,04
0,04
HKM11X
Wiring Diagrams
Type
K1W09D..MC, K1W12D..MC
K1W-VB
Pack
pcs.
1
D677E
Weight
kg/pc.
0,01
DC Solenoid Operated
Type
Coil voltage 1)
24
24V= DC
24VS 24V= DC with
protection 2)
Additional
Overload
Relay
see
page102
Type
Pack
pcs.
K1W09D01MC= . . .
K1W12D01MC= . . .
U12/16..K1
U12/16..K1
1
1
0,32
0,32
K1W09D10MC= . . .
K1W12D10MC= . . .
U12/16..K1
U12/16..K1
1
1
0,32
0,32
U12/16..K1
U12/16..K1
1
1
0,32
0,32
Weight
kg/pc.
Wiring Diagrams
0,32
K1W09L10MC= . . .
0,32
D677E
15
Mini Contactors
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Main Contacts
Type
V AC
690
2)
690
1)
165
165
400V AC
500V AC
690V AC
A
A
A
100
90
80
100
90
80
100
90
80
100
90
80
20
16
16
20
kW
kW
kW
kW
7,9
8,3
13,8
14,3
6
6,5
11
11,5
6
6,5
11
11,5
7,9
8,3
13,8
14,3
16
12
12
16
kW
kW
kW
kW
6,3
6,7
11
11,5
4,5
5
8
8,5
4,5
5
8
8,5
6,3
6,7
11
11,5
2,5
2,5
2,5
230V
240V
400V
415V
230V
240V
400V
415V
mm
220V
230V
240V
A
A
A
12
11,5
11
12
11,5
11
12
11,5
11
15
14,5
14
380-400V
415-440V
500V
660-690V
A
A
A
A
9
8
7
5
9
8
7
5
9
8
7
5
12
11
9
6,5
220-240V
380-440V
500-690V
kW
kW
kW
3
4
4
3
4
4
3
4
4
4
5,5
5,5
220V
230V
240V
A
A
A
12
11,5
11
12
11,5
11
12
11,5
11
15
14,5
14
380-400V
415-440V
500V
660-690V
A
A
A
A
9
8
7
5
9
8
7
5
9
8
7
5
12
11
9
6,5
220-240V
380-440V
500-690V
kW
kW
kW
3
4
4
3
4
4
3
4
4
4
5,5
5,5
1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
2) Suitable at 690V for pollution degree 2, Uimp = 6kV.
Pollution degree 3 Ui = 690V non-tracking of the printed circuit CTI 600
Pollution degree 3 Ui = 500V non-tracking of the printed circuit CTI 400
Pollution degree 3 Ui = 400V non-tracking of the printed circuit CTI 100
16
K1-12D..
165
690
K1-09L..
1)
165
K1-09F..
690
1)
at Ue = 690V AC
K1-09D..
D677E
Mini Contactors
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Main Contacts
Type
K1-09D..
K1-09F..
K1-09L..
K1-12D..
1 pole 24V
60V
110V
220V
A
A
A
A
20
20
5
0,6
16
16
5
0,6
16
16
5
0,6
20
20
5
0,6
A
A
A
A
20
20
20
16
20
20
20
16
20
20
20
16
20
20
20
16
1 pole 24V
60V
110V
220V
A
A
A
A
20
5
1
0,15
16
5
1
0,15
16
5
1
0,15
20
5
1
0,15
A
A
A
A
20
20
20
2
16
16
16
2
16
16
16
2
20
20
20
2
open
enclosed
open
enclosed
C
C
C
C
-50 to +90
gL (gG)
40
40
40
40
gL (gG)
25
25
25
25
gL (gG)
10
10
10
10
solid or stranded
flexible
flexible with multicore cable end
mm
mm
mm
0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
2
solid or stranded
AWG
18 - 14
Frequency of operations z
Contactors without thermal overload relay
Mechanical life
AC operated
DC operated
Fast on
Solder connector
1x 6,3 x 0,8
1,15
or
2x 2,8 x 0,8
-
0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
2
18 - 14
without load
AC3, Ie
AC4, Ie
DC3, Ie
1/h
1/h
1/h
1/h
10000
600
120
600
10000
600
120
600
10000
600
120
600
10000
700
150
700
Sx
Sx
106
106
5
15
5
15
5
15
5
15
10s-current
96
96
96
120
at Ie/AC3 400V
0,15
0,15
0,15
0,25
NO
NC
g
g
5
5
5
5
5
5
5
5
NO
NC
g
g
8
6
8
6
8
6
8
6
1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
D677E
17
Mini Contactors
Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1
Auxiliary Contacts
Type
V AC
690
1)
690
1)
1)
690 2)
10
6
10
6
690
1)
0,5
0,5
0,5
0,5
0,5
0,5
220-240V
380-415V
440V
A
A
A
3
2
1,6
3
2
1,6
3
2
1,6
3
2
1,6
3
2
1,6
3
2
1,6
500V
660-690V
A
A
1,2
0,6
1,2
0,6
1,2
0,6
1,2
0,6
1,2
0,6
1,2
0,6
60V
110V
220V
A
A
A
2
0,4
0,1
2
0,4
0,1
2
0,4
0,1
2
0,4
0,1
2
0,4
0,1
2
0,4
0,1
Storage
open
enclosed
C
C
C
DC operated
inrush
sealed
VA
VA
W
inrush
sealed
W
W
10
6
690 1)
HK..
at Ith
10
6
690
K1-07L..(=)
K1-09L..(=)
A
A
10
6
K1-07D..=
K1-09D..= K1-07D..= 24VR
K1-12D..= K1-09D..= 24VR K1-09F..(=)
40C
60C
K1-07D..
K1-09D..
K1-12D..
10
6
20
20
20
2,5
2,5
1,5
1,5
25
4-5
1,2
0,85 - 1,1
0,8 - 1,1
19 - 30V DC
20
20
20
25
4-5
1,2
25
4-5
1,2
2,5
2,5
2,5
2,5
0,85 - 1,1
0,85 - 1,1
make time
release time
arc duration
ms
ms
ms
15 - 25
8 - 25
10 -15
15 - 25
8 - 25
10 -15
15 - 25
8 - 25
10 -15
DC operated
make time
release time
arc duration
ms
ms
ms
15 - 19
8 - 25
10 -15
15 - 19
8 - 25
10 -15
15 - 19
8 - 25
10 -15
15 - 19
8 - 25
10 -15
0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
18 - 14
18 - 14
18 - 14
Cable cross-section
all connectors
solid
flexible
flexible with multicore cable end
mm2
mm2
mm2
AWG
2
18 - 14
1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
2) Suitable at 690V for pollution degree 2, Uimp = 6kV.
Pollution degree 3 Ui = 690V non-tracking of the printed circuit CTI 600
Pollution degree 3 Ui = 500V non-tracking of the printed circuit CTI 400
Pollution degree 3 Ui = 400V non-tracking of the printed circuit CTI 100
3) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced thermal rated current Ith to Ie /AC15
4) Summary switching time = release time + arc duration
5) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units).
18
0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
D677E
Type
K1-09D.. K1-09F..
K1W09D01
15
15
K1-09L..
20
1
3
3
2
3
3
440-480V
550-600V
hp
hp
5
7
5
7
5
7
7
10
110-120V
200-208V
220-240V
hp
hp
hp
1
1
1
1
1
1
1
2
30/5
Rated voltage
V AC
600
600
600 1)
A600
Q600
A600
Q600
2
3
3
100
400
100 - 400
600V
480V
240V
D677E
10
1
3
3
30/5
Ui
20
1
3
3
30/5
CTI - PWB
10
hp
hp
hp
A/kA
1) Pollution degree
HK..
110-120V
200-208V
220-240V
K1-07D.. K1-12D..
K1W12D01
AC
DC
A600
Q600
30/5
600
600
600
A600
Q600
A600
Q600
A600
Q600
19
Mini Contactors
Dimensions
AC and DC operated
with screw terminals
K1-07D..
K1-09D..
K1-12D..
K1-07F..
K1-09F..
AC and DC operated
with solder connections
K1-07L..
K1-09L..
HK..
Reversing Contactors
K1W09D..MC
K1W12D..MC
K1W09L..MC
K1W09D..MC + U12/16E K1
K1W12D..MC + U12/16E K1
20
D677E
Contactor Relays
D677E
22
22
23
Technical Data
24
Dimensions
26
21
Contactor Relays
AC Operated
Ratings
AC15
230V
A
Contacts
Therm. Built-in
Distinc.
Rated
Number
Current
acc. to
400V
A
Ith
A
NO NC
Additional
Contact
Blocks
Type
EN50011 Type
Coil voltage 1)
24V 50/60Hz
110V 50Hz 110-120V 60Hz
220-240V 50Hz 230-264V 60Hz
380-415V 50Hz 400-440V 60Hz
Pack Weight
pcs. kg/pc.
24
110
230
400
2
2
2
2
10
10
10
10
4
3
2
-
1
2
4
40E
31E
22E
04E
max. 4
HN..
K3-07ND40
K3-07ND31
K3-07ND22
K3-07ND04
.
.
.
.
.
.
.
.
.
.
.
.
1
1
1
1
0,22
0,22
0,22
0,22
3)
Type
NO NC
Pack
pcs.
EM LB
Weight
kg/pc.
2
2
2
2
10
10
10
10
1
-
1
-
1
-
HN10
HN01
HN10U
HN01U
10
10
10
10
0,02
0,02
0,02
0,02
HA10
HA01
10
10
0,03
0,03
3
3
25
25
1
-
D677E
DC Operated
Type
Coil voltage 1)
24
24V DC
60
60V DC
110 110V DC
220 220V DC
Contacts
Built-in
Distinc.
Number
acc. to
NO NC
EN50011 Type
.
.
.
.
.
.
.
.
.
.
.
.
4
3
2
-
1
2
4
Additional
Contact
Blocks
Pack
pcs.
Weight
kg/pc.
Wiring Diagrams
3)
40E
31E
22E
04E
max. 4
HN..
oder
HA..
1
1
1
1
0,53
0,53
0,53
0,53
A40, D40
A31, D31
.
.
.
.
.
.
.
.
.
.
.
.
4
3
2
-
1
2
4
2)3)
40E
31E
22E
04E
max. 4
HN..
1
1
1
1
0,53
0,53
0,53
0,53
A22, D22
A04, D04
.
.
.
.
.
.
.
.
.
.
.
.
4
3
2
1
2
-4
40E
31E
22E
04E
2)3)
max. 3
HN..
1
1
1
1
0,25
0,25
0,25
0,25
ND40=
ND31=
ND22=
ND04=
23
Contactor Relays
Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1
1)
Type
K3-07ND
V AC
690
690
690
690
10
6
10
6
20
16
10
6
10000
10
10000
10
10000
10
10000
50
A
A
Frequency of operations z
Mechanical life
1/h
S x 106
DC operated
K3-07ND= KG3-07A
KG3-07D
220-240V
380-415V
440V
A
A
A
4
2
1,6
4
2
1,6
12
4
4
4
2
1,6
500V
660-690V
A
A
1,2
0,6
1,2
0,6
3
1
1,2
0,6
24-60V
110V
220V
A
A
A
3,5
0,5
0,1
3,5
0,5
0,1
8
1
0,1
3,5
0,5
0,1
inrush
sealed
VA
VA
W
30 - 45
7 - 10
2,6 - 3
inrush
sealed
W
W
75
2
3
3
3
3
0,85 - 1,1
0,8 - 1,1
0,8 - 1,1
0,8 - 1,1
8 - 16
5 - 13
8 - 16
5 - 13
65 - 85
20 - 30 3)
65 - 85
20 - 30 3)
C
C
C
Cable cross-section
Connector
solid
flexible
flexible with multicore cable end
Magnet coil
solid
flexible
flexible with multicore cable end
20
20
mm2
mm2
mm2
0,75 - 6
1-4
0,75 - 4
mm2
mm2
mm2
0,75 - 2,5
0,75 - 2,5
0,5 - 1,5
25
20
Connector
Clamps per pole
Magnet coil
Clamps per pole
solid
flexible
AWG
AWG
18 - 10
18 - 10
2
solid
flexible
AWG
AWG
14 - 12
18 - 12
2
max.
10
10
20
10
V AC
600
600
600
600
A600
A600
A600
A600
1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
2) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced thermal rated current Ith according to Ie /AC15 3) with built-in coil suppressor
24
D677E
Contactor Relays
Position of Terminals
AC operated
K3-07ND22
K3-07ND40
K3-07ND04
KG3-07A40
KG3-07D40
KG3-07A04
KG3-07D04
K3-07ND22=
K3-07ND31=
K3-07ND40=
K3-07ND04=
DC solenoid operated
KG3-07A22
KG3-07D22
KG3-07A31
KG3-07D31
D677E
25
Contactor Relays
Dimensions
AC operated
DC solenoid operated
K3-07ND..
KG3-07..
26
HA10, HA01
D677E
Contactors
D677E
Contactor overview
28
30
31
Contactors 4-pole
32
33
34
Pneumatic Timers
Electronic Timers On-delay
Electronic Timers Off-delay
35
Mechanical Interlocks
Latches
Additional Terminals, Parallel Connectors
36
Indicator Units
Fuse Holders
Suppressor Units
37
Interface
Terminal Covers
Mounting Parts, Marking System
38
Control Voltages
40
40
41
Technical Data
44
Dimensions
64
27
Contactors 3-pole
Up to 1200A AC3
Up to 1350A AC1
DIN-rail mounting up to AC3 115A
International Approvals
Data according to IEC 947 / EN 60947
Ratings
AC3 400V
Motor
380-400V
660-690V
AC1
690V at 40C
Type
K3-
Auxiliary contacts
14A
18A
22A
24A
4kW
5,5kW
5,5kW
7,5kW
7,5kW
10kW
11kW
10kW
11kW
15kW
25A
25A
32A
32A
50A
65A
24A00
-
Type
K3-
Auxiliary contacts
Cable cross-section
Solid
Flexible
10A
1NO
1NO
1NC
mm2
mm2
50A
62A
74A
90A
115A
22kW
30kW
30kW
37kW
37kW
45kW
45kW
55kW
55kW
55kW
80A
110A
120A
130A
160A
200A
32A00
40A00
50A00
62A00
74A00
15kW 18,5kW
18,5kW 18,5kW
90A00 115A00
1NC
1NC
0,75 - 6
1-4
1,5 - 25
2,5 - 16
4 - 50
10 - 35
10 - 120
10 - 95
16
12
4
33 - 45
7 - 10
0,85 - 1,1
90 - 115
9 - 13
0,85 - 1,1
140 - 165
13 - 18
0,85 - 1,1
280
5
0,85 - 1,1
A
A
A
Mounting
40A
Auxiliary contact
Ith
40C
AC15 230V
400V
1NO
32A
HN10
1NO
f. low level
switching
-
HN01
1NC
f. low level
switching
-
HA10
1NO
25A Ith
HA01
1NC
25A Ith
HB11
1NO+1NC
f. low level
switching
2x DIN-rail
or base
max.
4 HN..
or
4 HA..
HB02
2NC
f. low level
switching
max.
7 HN..
or
7 HA..
max.
2 HB..
Type
U3/32
U12/16..K3
28
U3/74
U85
U3/42
16
0,12 - 30A
16
0,12 - 32A
4
10 - 42A
5
20 - 74A
2
60 - 120A
D677E
150A
175A
210A
260A
315A
450A
550A
700A
860A
1000A
1200A
75kW
90kW
90kW
110kW
110kW
160kW
132kW
210kW
160kW
250kW
250kW
375kW
300kW
475kW
400kW
630kW
500kW
700kW
580kW
850kW
680kW
1000kW
230A
250A
350A
450A
500A
600A
760A
1000A
1100A
1200A
1350A
151A00
176A00
210A00
260A00
316A00
450A22
550A22
700A22
860A22
1000A12
1200A12
busbar
30x6
busbar
30x6
busbar
30x6
2 x 16-120
2 x 16-120
2NO+2NC 2NO+2NC
busbar
30x5
busbar
40x6
350
350
5
5
0,85 - 1,1
360
5
360
5
0,85 - 1,1
2NO+2NC 2NO+2NC
busbar
50x8
busbar
50x8
1NO+2NC 1NO+2NC
busbar
50x10
10
3
2
360
5
800-950
9-11
busbar
50x10
10
3
2
800-950
1350-1600 1350-1600
9-11
21-25
21-25
0,85 - 1,1
2400
2400
70
70
0,85-1,1
base
HKT11
HKT22
1NO+1NC 2NO+2NC
max. 1 pc.
HKA11
1NO+1NC
max. 2 pcs.
HKF22
2NO+2NC
max. 1 pc.
U180
U320
U800
1
120 - 180A
2
144 - 320A
3
240 - 800A
integrated
integrated
D677E
SU840/550
HKB11
1NO+1NC
max. 2 pcs.
SU840/860
29
Contactors 3-pole
AC Operated
Ratings
AC2, AC3
380V
400V
660V
415V
690V
kW
kW
Rated
Current
AC1
690V
A
Aux. Contacts
Built-in Additional
see
page 34
NO NC
Typ
max. 4
HN.. or
HA..
4
4
5,5
5,5
25
25
1
-
5,5
5,5
7,5
7,5
25
25
1
-
10
10
32
32
1
-
11
11
10
10
32
32
11
15
18,5
15
18,5
18,5
22
30
37
Type
Coil voltage 1)
24V 50/60Hz
110V 50/60Hz
220-240V 50Hz
380-415V 50Hz Pack
pcs.
24
110
230
400
W
K3-10ND10 . . .
K3-10ND01 . . .
1
1
0,23
0,23
K3-14ND10 . . .
K3-14ND01 . . .
1
1
0,23
0,23
K3-18ND10 . . .
K3-18ND01 . . .
1
1
0,23
0,23
1
-
K3-22ND10 . . .
K3-22ND01 . . .
1
1
0,23
0,23
50
65
80
max. 4
HN.. or
HA..
and 2HB..
K3-24A00 . . .
K3-32A00 . . .
K3-40A00 . . .
1
1
1
0,48
0,48
0,48
30
37
45
110
120
130
max. 4 (3)2)
HN.. or
HA..
and 2HB..
K3-50A00 . . .
K3-62A00 . . .
K3-74A00 . . .
1
1
1
0,85
0,85
0,85
45
55
55
55
160
200
max. 7
HN.. or
HA..
and 2HB..
K3-90A00 . . . 3)
K3-115A00 . . . 3)
1
1
2,2
2,2
75
90
110
132
230
250
1 HKT..
and
2 HKA11
K3-151A00 . . .
K3-176A00 . . .
3)
1
1
4
4
110
132
160
160
210
250
350
450
500
K3-210A00 . . .
K3-260A00 . . .
K3-316A00 . . .
3)
1
1
1
7,2
7,2
7,2
250
300
375
475
600
760
2
2
2
2
K3-450A22 . . .
K3-550A22 . . .
1
1
13
13,5
400
500
630
700
1000
1100
2
2
2
2
K3-700A22 . . .
K3-860A22 . . .
1
1
26,5
27,6
580
680
850
1000
1200
1350
1
1
2
2
K3-1000A12 . . .
K3-1200A12 . . .
1
1
49
53
7,5
7,5
1 HKF22
2 HKB11
3)
3)
3)
Weight
kg/pc.
D677E
DC Operated
Type
Coil voltage 1)
24 24V DC
48 48V DC
110 110V DC
W
Coil
power
inrush/
hold
W/W
Additional
Overload
Relay
see
page 102
Type
Wiring Diagram
Pack
pcs.
Weight
kg/pc.
1
1
0,53
0,53
1
1
0,53
0,53
.3)
KG3-10A10 . .
KG3-10A01 . . .3)
3/3
3/3
KG3-14A10 . . .3)
KG3-14A01 . . .3)
3/3
3/3
KG3-18A10 . . .3)
KG3-18A01 . . .3)
3/3
3/3
1
1
0,53
0,53
KG3-22A10 . . .3)
KG3-22A01 . . .3)
3/3
3/3
1
1
0,53
0,53
KG3-24A00 . . .3)
KG3-32A00 . . .3)
KG3-40A00 . . .3)
4/4
4/4
4/4
U3/32
U3/42
UAT..
1
1
1
0,57
0,57
0,57
K3-50A00= . . .
K3-62A00= . . .
K3-74A00= . . .
200/6
200/6
200/6
U3/74
1
1
1
0,9
0,9
0,9
K3-90A00 . . . 2)3)
K3-115A00 . . . 2)3)
280/5
280/5
U85
1
1
2,2
2,3
K3-151A00 . . . 2)3)
K3-176A00 . . . 2)3)
350/5
350/5
U180
1
1
4
4
K3-210A00 . . . 2)3)
K3-260A00 . . . 2)3)
K3-316A00 . . . 2)3)
360/5
360/5
360/5
U320
1
1
1
7,2
7,2
7,2
K3-450A22 . . . 2)
K3-550A22 . . . 2)
800/10
800/10
U800
+SU840/550
1
1
13
13,5
K3-700A22 . . . 2)
K3-860A22 . . . 2)
1500/20
1500/20
U800
+SU840/860
1
1
26,5
27,6
K3-1000A12= . . .
K3-1200A12= . . .
2100/60
2100/60
1
1
49
53
U3/32
U12/16E
U12/16EQ
UAT21
Coil Circuits
see page 41
Terminal Markings
A10
A01
A00
A00=
A00
A22
A12
31
Contactors 3-pole
DC Operated
Ratings
AC2
AC3
380V
400V 660V
415V 690V
kW
kW
Rated
Current
AC1
Aux. Contacts
Built-in Additional
see
page 34
690V
A
NO NC Type
4
4
5,5
5,5
25
25
1
-
5,5
5,5
7,5
7,5
25
25
1
-
32
32
1
-
32
32
50
65
80
7,5 10
7,5 10
11
11
10
10
11
15
18,5
15
18,5 18,5
Type
24
60
110
220
Coil voltage 1)
24V= DC
60V= DC
110V= DC
220V= DC
Pack Weight Wiring Diagram
pcs. kg/pc.
K3-10ND10= . . .
K3-10ND01= . . .
1
1
0,25
0,25
K3-14ND10= . . .
K3-14ND01= . . .
1
1
0,25
0,25
K3-18ND10= . . .
K3-18ND01= . . .
1
1
0,25
0,25
1
-
K3-22ND10= . . .
K3-22ND01= . . .
1
1
0,25
0,25
K3-24A00= . . .
K3-32A00= . . .
K3-40A00= . . .
1
1
1
0,55
0,55
0,55
max. 3
HN..
or
HA..
max. 4
HN.. or
HA..
+ 2HB..
Contactors 4-pole
A01=
... A00=
AC Operated
Ratings
AC2 AC1
AC3
380V
400V
415V 400V
kW
kW
AC1
Aux. Contacts
Built-in Additional
see
page 34
690V
A
NO NC Type
25
25
7,5 22
22
11
32
32
11
31
34,5
15
18,5 34,5
45
50
50
4
17,5
5,5 17,5
Rated
Current
Type
24
110
230
400
Coil voltage 2)
24V 50/60Hz
110V 50/60Hz
220-240V 50Hz
380-415V 50Hz
Pack Weight Wiring Diagram
pcs. kg/pc.
max. 4
HN.. or
HA..
K3-10NA00-40 . . .
K3-14NA00-40 . . .
1
1
0,22
0,22
K3-18NA00-40 . . .
K3-22NA00-40 . . .
1
1
0,22
0,22
max. 4
HN..
or
HA..
K2-23A00-40 . . .
K2-30A00-40 . . .
K2-37A00-40 . . .
1
1
1
0,65
0,65
0,65
22
30
55
69
80
100
max. 6
HN.. or
HA..
K2-45A00-40 . . .
K2-60A00-40 . . .
1
1
1,1
1,1
55
75
90
139
159
173
200
230
250
1HKT..
+
2xHKA11
K3-116A00-40 . . .3)
K3-151A00-40 . . .3)
K3-176A00-40 . . .3)
1
1
1
4,7
4,7
4,7
110
132
160
242
310
346
350
450
500
K3-210A00-40 . . .3)
K3-260A00-40 . . .3)
K3-316A00-40 . . .3)
1
1
1
8
8
8
A10=
D677E
A00-40
660V
690V
kVAr
12,5 0-13
0-12,5
0-12,5
12,5 0-13
0-20
0-20
Aux.
Contacts
Built-in Add.
Type
Coil voltage 1)
220-240V 50Hz
Pack Weight
pcs. kg/pc.
230
NO NC pcs.
1
-
- 1 2)
1 1 2)
K3-18NK10 . . .
K3-18NK01 . . .
1
1
0,34
0,34
3 3)
3 3)
K3-24K00 . . .
K3-32K00 . . .
1
1
0,62
0,62
3 3)
3 3)
3 3)
K3-50K00 . . .
K3-62K00 . . .
K3-74K00 . . .
1
1
1
1,0
1,0
1,0
33-80
80 36-82 57-120 33-75 36-77 57-120 1006) 36-1036) 57-1486) 33-906) 36-936) 57-1486) 33-100
6 5)
6 5)
K3-90K00 . . .
K3-115K00 . . .
1
1
2,3
2,3
10-20
20
25
10-25
0-20
0-20
10,5-22 17-33
10,5-27 17-41
0-12,5
0-12,5
0-13
0-13
10-20
10-25
10,5-22 17-33
10,5-27 17-41
20-33,3
20-33,3 23-36
33,3 23-36 36-55
50 23-53 36-82
20-50
20-50 23-53
754) 23-754) 36-1204) 20-60 23-64
20-75
36-55
36-82
36-100
Specification: Contactors K3-..K are suitable for switching low-inductive and low loss capacitors in capacitor banks
(IEC70 and 831, VDE 0560) without and with reactors.
Capacitor switching contactors are fitted with early make contacts and damping resistors, to reduce the value of make
current <70 x Ie.
Operating Conditions: Capacitor switching contactors are protected against contact welding for a prospective making
current of 200 x Ie.
Technical Data acc. to IEC 947-4-1, IEC 947-5-1, EN 60947-4-1, EN 60947-5-1, VDE 0660
Type
K3-18K
K3-24K
K3-32K
K3-50K
K3-62K
K3-74K
K3-90K
K3-115K
1/h
120
120
120
120
120
80
80
80
Contact life
S x 103
S x 103
250
400
150
300
150
300
150
300
150
300
120
200
120
200
120
200
at 50C
at 60C
A
A
0-18
0-18
14-28
14-28
14-36
14-36
30-48
30-48
30-72
30-72
30-108
30-87
50-115
50-108
50-144
50-130
at 50C
at 60C
A
A
32
32
45
40
60
55
100
90
110
100
120
110
155
145
190
170
Overload factor
acc. to EN 61921: 30% min.
at 50C
at 60C
%
%
78
78
60
43
67
53
108
88
53
39
11
26
35
34
32
31
from / to
35 / 63
50 / 80
63 / 100
160/200
160/250
Fuses gL (gG)
Typical
Circuit Diagram
33
Auxiliary Contact Blocks for contactors K(G)3-07.. to K3-115.., type HN.. for low level switching 1)
Rated
AC15
230V
A
Operational Current
AC15 AC1
400V 690V
A
A
Type
Contacts
NO
NC
EM
LB
Pack
Weight
pcs.
kg/pc.
3
3
2
2
10
10
1
-
HN10
HN01
10
10
0,02
0,02
3
3
2
2
10
10
1
-
HN10U
HN01U
10
10
0,02
0,02
6
6
3
3
25
25
1
-
HA10
HA01
10
10
0,03
0,03
Auxiliary Contact Block for contactors K3-24.. to K3-115.., for low level switching 1)
Rated
AC15
230V
A
3
3
Operational Current
AC15 AC1
mounting:
400V 690V
1 HB.. on left side
A
A
and 1 HB.. on right side
2
2
10
10
Contacts
NO
1
-
Type
NC
1
2
Pack
Weight
pcs.
kg/pc.
HB11
HB02
10
10
Type
Pack
Weight
pcs.
kg/pc.
0,02
0,02
Operational Current
AC15 AC1
400V 690V
A
A
For contactors
Contacts
NO
NC
3
3
3
2
2
2
10
10
10
1
2
1
1
2
1
HKT11
HKT22
HKA11
1
1
1
0,04
0,05
0,05
6
6
3
3
16
16
K3-200 to K3-860 2)
K3-1000, K3-1200 inside
2 2)
1
2
1
HKF22
HKB11
1
1
0,12
0,17
Snap-on Momentary Contacts for K(G)3-07.. to K3-115.. for low level switching1)
Rated
AC15
230V
A
3
3
Operational Current
AC15 AC1
400V 690V
A
A
Specification
2
2
10
10
Contacts
manual operated
manual operated
NO
NC
1
-
Type
HTN10
HTN01
Pack
Weight
pcs.
kg/pc.
10
10
0,02
0,02
Type
Pack
pcs.
K2-DK
K2-SK
10
10
1)Contacts suitable for electronic circuits, according to IEC60947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
Technical data see page 62
2) Contact travel of make contacts adjustable, see page 63
34
D677E
Weight
kg/pc.
0,02
0,02
Contacts
Function
Pack
Weight
pcs.
kg/pc.
Time Range
s
NO NC NO NC
On-delay
On-delay
0,1 - 40
10 - 180
1
1
1
1
K2-TP40DE
K2-TP180DE
1
1
0,09
0,09
Off-delay
Off-delay
0,1 - 40
10 - 180
1
1
1
1
K2-TP40IA
K2-TP180IA
1
1
0,09
0,09
Wiring Diagram
Type
Rated Current
AC15
A
24 - 60V AC/DC
100 - 250V AC/DC
1 - 30
1 - 30
0,75
0,75
K2-TE30 60
K2-TE30 250
1
1
0,08
0,08
24 - 60V AC/DC
100 - 250V AC/DC
10 - 180
10 - 180
0,75
0,75
K2-TE180 60
K2-TE180 250
1
1
0,08
0,08
24 - 60V AC/DC
100 - 250V AC/DC
30 - 600
30 - 600
0,75
0,75
K2-TE600 60
K2-TE600 250
1
1
0,08
0,08
Operational
Voltage
V
Time Range
Timing Chart
Control voltage
LED
brown
Contactor
Pack
Weight
pcs.
kg/pc.
Operation Range
Time repeat accuracy
Recovery time (typical)
0,8 - 1,1 x Us
1%
50ms
<3V
25A <10ms
Duty Cycle
Ambient temperature
Short circuit protection
100%
-40o - +60oC
2A
Wiring Diagram
white
Type
Rated Current
AC15
A
24 - 60V AC
100 - 120V AC
200 - 250V AC
1 - 30
1 - 30
1 - 30
0,75
0,3
0,15
K2-TA30 60
K2-TA30 120
K2-TA30 250
1
1
1
0,08
0,08
0,08
24 - 60V AC
100 - 120V AC
200 - 250V AC
10 - 180
10 - 180
10 - 180
0,75
0,3
0,15
K2-TA180 60
K2-TA180 120
K2-TA180 250
1
1
1
0,08
0,08
0,08
24 - 60V AC
100 - 120V AC
200 - 250V AC
30 - 600
30 - 600
30 - 600
0,75
0,3
0,15
K2-TA600 60
K2-TA600 120
K2-TA600 250
1
1
1
0,08
0,08
0,08
Operational
Voltage
V
Timing Chart
brown
Time Range
Operation Range
D677E
Weight
pcs.
kg/pc.
0,8 - 1,1 x Us
1%
15ms
15ms
Voltage Drop
LED Max. inrush current (peak value)
Contactor
Duty Cycle
Ambient temperature
Short circuit protection
<0,7V
25A <10ms
Pack
100%
-40o - +40oC
2A
24 - 60V
0,75A
Power
Consumption
24V DC
0,35W
0,75A
Amplifier element for contactor control
by programmable controller
0,5A
Type
Pack
pcs.
K2-IM
Weight
kg/pc.
0,03
Rated Voltage
Type
250V AC
K2-F
Pack
pcs.
1
Weight
kg/pc.
0,02
Rectifier with Fuse Holder for contactors K(G)3-07.. to K3-115.. and K2-..
Specifications
Rated Voltage
Type
250V AC
250V AC
K2-RF1
K2-RF3
Pack
pcs.
1
1
Weight
kg/pc.
0,03
0,03
For Contactors
24
110
230
400
Coil voltage
22-26V 50/60Hz
100-120V 50/60Hz
210 -250V 50/60Hz
360-440V 50/60Hz
Pack
pcs.
Weight
kg/pc.
K2-L22 . . .
0,08
K2-L40 . . .
0,08
K2-L74 . . .
0,08
Voltage
Range
Type
Pack
pcs.
Weight
kg/pc.
K2-ING
K2-INR
10
10
0,02
0,02
Voltage Indicator
Indicator, clear (glow-disc. l.)
220 - 415V AC/DC
Voltage Indicator
Indicator, red (LED)
24 - 120V AC/DC
To connect parallel to the contactor coil. In case of applied
voltage the indication also lights at coil interruption.
K2-UN
K2-UNR
10
10
0,02
0,02
For Type
Type
Snap-On Adapter
36
Specification
Pack
pcs.
K2-SM
10
D677E
Weight
kg/pc.
0,009
Type
Pack
pcs.
Weight
kg/pc.
325
500
760
NP325
NP500
NP760
1
1
1
0,7
1,3
1,4
500
1000
1000
NP501
NP1000
NP1001
1
1
1
1,3
1,6
1,6
Mechanical Interlocks
Mounting
Type
K3-07 to K3-40
KG3-07 to KG3-22
KG3-24 to KG3-40
K2-07 to K2-37
K3-07 to K3-40
KG3-07 to KG3-22
KG3-24 to KG3-40
K2-07 to K2-37
horizontal
LG10889 1)
10
0,006
K3-24 to K3-74
K2-23 to K2-60
K3-50 to K3-74
K2-45 to K2-60
horizontal
LG10890 1)
0,010
K3-90, K3-115
K3-90, K3-115
horizontal
LG11478 1)
0,010
K65 to K110
K65 to K110
horizontal
LG8511
0,076
K3-116 to K3-316
K3-116 to K3-316
horizontal
LG11223H
0,06
K3-315 to K3-550
K3-315 to K3-550
K3-450, K3-550
K3-450, K3-550
K3-315 to K3-550
K3-315 to K3-550
K3-700, K3-860
K3-700, K3-860
horizontal
vertical
horizontal
vertical
LG10400H
LG10400V
LG10399H
LG10399V
1
1
1
1
0,8
0,8
1,6
0,9
K3-700, K3-860
K3-700, K3-860
K3-700, K3-860
K3-700, K3-860
K3-700, K3-860
K3-700, K3-860
K3-1000, K3-1200
K3-1000, K3-1200
horizontal
vertical
horizontal
vertical
LG10402H
LG10402V
LG10401H
LG10401V
1
1
1
1
1,5
0,9
1,9
1,6
K3-1000, K3-1200
K3-1000, K3-1200
K3-1000, K3-1200
K3-1000, K3-1200
horizontal
vertical
LG10403H
LG10403V
1
1
1,8
1,5
Pack
pcs.
Weight
kg/pc.
Specification
Type
for 6 terminals
LG9333
0,045
for 3 terminals
for 4 terminals
for 3 terminals
LG10404
LG104044
LG11457
1
1
1
0,12
0,14
0,14
K3-200
K3-315, K3-450
for 3 terminals
for 3 terminals
LG10405
LG10406
1
1
0,18
0,28
K3-550
K3-700
K3-860
for 3 terminals
for 3 terminals
for 3 terminals
LG10407
LG10408
LG10409
1
1
1
0,34
0,39
0,49
Pack
pcs.
Weight
kg/pc.
Additional Terminals
For Contactors
Type
Cable Cross-sections to clamp mm
solid or
flex. with multistranded
flexible
core cable end
Pack
Weight
pcs.
kg/pc.
LG9339
0,009
LG11224
0,10
LG9030
0,052
LG9031
0,170
37
Parallel Connectors
For Contactors
Type
Cable Cross-sections to clamp mm
solid or
flex. with multistranded
flexible
core cable end
Pack
Weight
pcs.
kg/pc.
LG9241
50
0,004
LG5587
10
0,022
LG7360
10
0,006
Suppressor Units
Voltage Range
V
Type
Mounting
Pack
pcs.
Weight
kg/pc.
VG-K2/24
VG-K2/48
VG-K2/230
VG-K2/400
10
10
10
10
0,02
0,02
0,02
0,02
RC-K3 N24
RC-K3N 110
RC-K3 N230
10
10
10
0,01
0,01
0,01
RC-AD22/48
RC-AD047/230
RC-AD047/400
5
5
5
0,02
0,02
0,02
Mounting Parts
Specification
Type
Description
For Type
Clamp,
no distance
P426-1
50
0,001
Clamp,
7mm distance
P418-1
10
0,002
Clamp,
K3-07 to K3-115 To join contactors
12mm distance K2-07 to K2-37 with 12mm distance,
2 pieces required
P807-1
10
0,002
Clamp
asymmetric
P785-1
10
0,002
K3-07 to K3-40
To join contactors
with K3-50 - K3-74 with 12mm distance,
2 pieces required
Pack
pcs.
Weight
kg/pc.
Marking System for contactors K3-07.. to K3-115.., K2-.. and aux. contact blocks HN and HA
38
Description
Specification
Type
Pack
pcs.
Marking Plate
Marking Plate
Marking Plate
P487-1
P971-1
P245-1
100
100
100
0,025
0,038
0,050
Marking Plate
P245-K..
100
0,013
D677E
Weight
kg/100pc
Suffix
to
contactor
type
Suffix
to
contactor
type
to
coil
type
Voltage Marking
at the coil
for
for
50Hz
60Hz
V
V
range
for 50Hz
min. max.
V
V
6
6,6
7,3
41.6
41.6,6
41.7,3
6
6,6
7,3
8
9
10
41.8
41.9
41.10
8
9
10
11
12
13,2
41.11
41.12
41.13
11
12
13,2
14,5
16
18
41.14
41.16
41.18
14,5
16
18
20
24
25
41.20
4.24
41.25
20
24
25
27
31
33
41.27
41.32
41.33
36
40
42
6
6,6
7,3
6,6
7,3
8
for 60Hz
min. max.
V
V
6,6
7,3
8
7,3
8
9
8
9
10
9
10
11
9
10
11
11
12
13,2
12
13,2
14,5
12
13,2
13,2 14,5
14,5 16
14,5
16
18
16
18
20
16
18
20
18
20
22
24
20
22
24
22
24
27
22
24
27
24
27
30
27
32
36
32
36
36
27
30
33
30
33
36
30
33
36
33
36
39
41.36
41.40
4.42
36
42
42
42
42
48
36
39
42
39
42
47
39
42
47
42
47
52
48
55
60
41.48
41.55
41.60
48
55
60
48
60
44
52
58
48
58
65
48
58
65
52
65
72
65
75
85
41.65
41.75
41.85
65
75
85
65
72
80
72
80
90
72
80
90
80
90
100
90
110
115
41.90
4.110
41.115
100
100
110 110-120
115
125
90
100
110
100
110
122
100
110
122
110
122
135
127
140
150
41.127
41.140
41.150
127
140
150
122
135
150
135
150
165
135
150
165
150
165
180
165
180
200
41.165
41.180
41.200
165 180-208
180-210 200-240
200-2301) 220-240
165 180
180 210
200 2301)
180
200
220
208
240
240
230
254
270
4.230
41.254
41.270
220-240 230-264
254
277
270
220
240
264
230
264
290
264
290
315
300
320
345
41.300
41.320
41.345
300
320
345-4001) 380-4401)
290 315
315 345
345 4001)
315 345
345 380
380 4401)
400
415
440
4.400
41.415
41.440
380-415 400-440
415-440 440-480
440-480 480-500
380
400
440
415
440
480
400
440
480
460
480
530
480
500
41.480
41.500
480-500 530-580
500-550 550-600
480
500
530
550
530
550
580
600
550
41.550
550-600
550
600
600 (650)
12
600
240
264
290
10
11
12
to
coil
type
20
24
42
4.20
4.24
4.42
110
230
400
4.110
4.230
4.400
Voltage Marking
at the coil
for
for
50Hz
60Hz
V
V
range
for 50Hz
min. max.
V
V
20
24
42
for 60Hz
min. max.
V
V
24
20
24
42
22
27
47
24
29
50
26
32
56
110-120
277
220-240
380-415 460-480
110
220
380
122
240
415
132
264
455
146
288
498
4.110
4.230
4.400
110-115
220-230
380-400
110
220
380
115
230
400
110
220
380
115
230
400
440
4.440
440
440
440
440
440
to
coil
type
Voltage Marking
at the coil
for
for
50/60Hz DC
V
V
range
for 50Hz
min. max.
V
V
for 60Hz
min. max.
V
V
24
48
110
4.24
4.48
4.110
24
48
110-120
24
48
110
22
44
110
24
48
120
22
44
110
24
48
120
230
400
4.230
4.400
220-240
380-415
220
-
220
380
240
415
220
380
240
415
1) Operating range of magnet-coils: 0,85 x Us (min. value of rated control voltage) up to 1,05 x Us (max. value of rated control voltage)
D677E
39
For Contactors
4.24
4.42
4.110
41.180
4.230
4.400
K3-07N.. up to K3-22N..
K3-07.. up to K3-22..
K2-07.. up to K2-16..
K10N/ . . .EUR
K3-6/ . . .
K6/ . . .
K3-24.. up to K3-40..
K2-23.. up to K2-37..
K3-50.. up to K3-74.., K2-45.., K2-60..
K65.., K85..
K110..
10
10
10
0,053
0,040
0,040
K24/ . . .
K23/ . . .
K45/ . . .
1
1
1
0,085
0,085
0,110
K85/ . . .
K110/ . . .
1
1
0,215
0,220
Type
For Contactors
K3-150.., K3-175..
K3-1000.., K3-1200..
Coil voltage 1)
24V 50Hz
42V 50Hz
110V 50Hz
180V 50Hz, 220V 60Hz
220-240V 50Hz
380-415V 50Hz
Pack Weight
pcs.
kg/pc.
4.110
4.230
4.400
W
Coil voltage 1)
110V 50Hz, 110-115V 60Hz
220-230V 50Hz
380-400V 50Hz
pcs.
kg/pc.
K3-175/ . . .
K3-1200/ . . .
1
1
0,38
3,12
For Contactors
4.24
4.110
4.230
4.400
W
Coil voltage 1)
24V 50/60Hz / 24V DC
110-120V 50/60Hz / 110V DC
220-240V 50/60Hz / 220V DC
380-415V 50/60Hz
pcs.
kg/pc.
K3-90.., K3-115..
K3-151.., K3-176..
K3-210.., K3-316..
K3-115/ . . .
K3-176/ . . .
K3-316/ . . .
1
1
1
0,30
0,68
0,68
K3-450.., K3-550..
K3-700.., K3-860..
K3-550/ . . .
K3-860/ . . .
1
1
1,63
2,44
For Contactors
for coils
K3-450.., K3-550..
K3-700.., K3-860..
K3-550/4...
K3-860/4..
Type
110
230
400
Coil voltage 1)
110-120V 50/60Hz / 110V DC
220-240V 50/60Hz / 220V DC
380-415V 50/60Hz
Pack Weight
pcs.
kg/pc.
K3-550/FG . . .
K3-860/FG . . .
1
1
D677E
0,33
0,54
Type
For Contactors
47.24
47.110
47.220
Coil voltage 1)
24V DC
110V DC
220V DC
Pack
pcs.
Weight
kg/pc.
K10N/ . . .
K3-6/ . . .
K6/ . . .
1
1
1
0,052
0,042
0,042
K3-24..= up to K3-40..=
HN01X
K2-23..= up to K2-37..=
HN01X
K3-50..= up to K3-74..=, K2-45..=, K2-60..= HN01Z
K24/ . . .
K23/ . . .
K45/ . . .
1
1
1
0,090
0,090
0,115
K65..=, K85..=
K110..=
K85/ . . .
K110/ . . .
1
1
0,220
0,225
K3-07N..= up to K3-22N..=
K3-07..= up to K3-22..=
K2-07..= up to K2-16..=
HN01U
HN01U
HN01U
Type
For Contactors
K3-1000..=, K3-1200..=
43.110
43.220
W
Coil voltage 1)
110V DC
220V DC
K3-1200/ . . .
pcs.
1
kg/pc.
3,12
DC operated
with double winding coil
K3-07..=
up to K3-22..=
K3-07..
up to K110..
AC and DC operated
with double winding coil
K3-90A00, K3-115A00
K3-151A00, K3-176A00
K3-210A00 to K3-316A00
DC operated
KG3..
AC and DC operated
with series resistor
K3-200A21
K3-315A21
K3-24..=
to
K3-74..=
K85..=
K110..=
AC and DC operated
with series resistor
K3-450.. up to K3-860..
DC operated
with DC coil
K3-1000.., K3-1200..
AC operated
with DC coil
K3-1000.., K3-1200..
41
Spare Contacts
42
Main Contacts
for Contactors
Type
K85..
K110..
EK85/1
EK110/1
3
3
0,235
0,275
K3-150..
K3-151..
K3-175..
EK3-150/10
EK3-151/10
EK3-175/10
1
1
1
0,32
0,16
0,32
K3-176..
K3-200..
K3-210..
EK3-176/10
EK3-200/10
EK3-210/10
1
1
1
0,16
0,18
K3-260..
K3-315..
K3-316..
EK3-260/10
EK3-315/10
EK3-316/10
1
1
1
0,34
K3-450..
K3-550..
K3-700..
EK3-450/10
EK3-550/10
EK3-700/10
1
1
1
0,35
0,35
0,85
K3-860..
K3-1000..
K3-1200..
EK3-860/10
EK3-1000/10
EK3-1200/10
1
1
1
1,0
1,4
1,4
Pack
pcs.
D677E
Weight
kg/pc.
kW
Range
according to
BS for
415V
F.L.C.
PS~hp hp cos %
220-230V Value
Motor of fusing at
motor start
D.O.L. YD
F.L.C.
A
A
A
240V
Value
Motor of fusing at
motor start
D.O.L. YD
F.L.C.
A
A
A
380-400V Value
Motor of fusing at
motor start
D.O.L. YD
F.L.C.
A
A
A
415V
Value
Motor of fusing at
motor start
D.O.L. YD
A
A
A
500V
Value
Motor of fusing at
motor start
F.L.C. D.O.L. YD
A
A
A
660-690V Value
Motor of fusing at
motor start
F.L.C. D.O.L. YD
A
A
A
0,06
0,09
0,12
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
2,5
3
3,7
4
5,5
7,5
8
11
12,5
15
18,5
20
22
25
30
37
40
45
51
55
59
75
90
110
129
132
147
160
184
200
220
250
257
295
315
355
400
0,08
0,12
0,16
0,24
0,34
0,5
0,75
1
1,5
2
3
3,4
4
5
5,5
7,5
10
11
15
17
20
25
27
30
34
40
50
54
60
70
75
80
100
125
150
175
180
200
220
250
270
300
340
350
400
430
483
545
0,38
0,55
0,76
1,1
1,4
2,1
2,7
3,3
4,9
6,2
8,7
9,8
11,6
14,2
15,3
20,6
27,4
28,8
39,2
43,8
52,6
64,9
69,3
75,2
84,4
101
124
134
150
168
181
194
245
292
358
420
425
472
502
590
626
700
803
826
948
990
-
0,35
0,5
0,68
1
1,38
1,93
2,3
3,1
4,1
5,6
7,9
8,9
10,6
13
14
18,9
24,8
26,4
35,3
40,2
48,2
58,7
63,4
68
77,2
92,7
114
123
136
154
166
178
226
268
327
384
393
432
471
541
589
647
736
756
868
927
-
0,22
0,33
0,42
0,64
0,88
1,22
1,5
2
2,6
3,5
5
5,7
6,6
8,2
8,5
11,5
15,5
16,7
22
25
30
37
40
44
50
60
72
79
85
97
105
112
140
170
205
242
245
273
295
340
370
408
460
475
546
580
636
710
2
2,5
3,5
5
6,5
7,5
11
14
21
28
35
40
55
66
80
105
135
165
200
230
260
325
385
450
500
-
0,16
0,24
0,33
0,46
0,59
0,85
1,2
1,48
2,1
2,6
3,8
4,3
5,1
6,2
6,5
8,9
11,9
12,7
16,7
19
22,5
28,5
30,6
33
38
44
54
60
64,5
73,7
79
85,3
106
128
156
184
186
207
220
259
278
310
353
363
416
445
483
538
0,7
0,9
1,1
1,5
2
2,9
3,5
4,9
6,7
9
13
17,5
21
25
33
42
49
60
82
98
118
140
170
215
268
337
366
410
Motor
rating
1
1,5
2
3
4
5
7,5
10
15
20
25
30
40
50
60
80
100
125
150
175
200
250
300
350
400
-
0,7
0,7
0,7
0,7
0,7
0,72
0,75
0,8
0,83
0,83
0,83
0,83
0,84
0,84
0,84
0,85
0,86
0,86
0,86
0,86
0,86
0,86
0,86
0,87
0,87
0,87
0,87
0,87
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,89
0,89
59
60
61
61
62
64
69
74
77
78
81
81
81
82
82
83
85
85
87
87
87
88
88
89
89
90
90
90
91
91
91
91
91
92
92
92
92
93
93
93
93
93
93
93
93
93
95
96
1
2
2
2
4
4
4
6
10
10
16
16
20
25
25
35
35
50
63
63
80
100
100
100
125
125
160
160
200
200
250
250
315
400
500
500
500
630
630
800
800
1000
1000
1000
1250
1250
-
1
2
2
2
2
4
4
4
6
10
10
16
16
20
20
25
35
35
50
50
63
80
80
80
100
125
160
160
160
200
200
250
250
315
400
500
500
630
630
630
800
800
1000
1000
1000
1250
-
1
1
2
2
2
2
2
2
4
2
4
4
4
4
6
4
6
6
10
10
16
10
16
10
20
16
25
16
25
20
35
25
35
35
35
35
50
50
63
50
80
63
80
63
80
80
100
80
100 100
125 100
160 125
160 160
200 160
200 200
200 200
250 200
315 250
315 315
400 400
500 400
500 500
630 500
630 630
630 630
800 630
800 800
1000 800
1000 800
1000 1000
1250 1000
-
The motor F.L.C. be valid for standard internal and surface cooled three-pole
motors with 1500 min-1. The fuses values be valid for the motor F.L.C. shown in the
table and D.O.L.-start: starting current max. 6x motor F.L.C., starting time max. 5s;
star-delta-start: starting current max. 2x motor F.L.C., starting time max. 15s. For
1
1
2
2
2
4
4
4
4
6
10
10
16
16
16
20
25
25
35
35
50
63
63
63
80
80
100
100
125
125
160
160
200
250
250
315
315
315
400
400
500
500
630
630
800
800
800
1000
1
1
2
2
2
2
2
4
4
4
6
10
10
10
10
16
20
20
25
35
35
50
50
50
63
63
80
100
100
100
125
125
160
200
250
250
250
315
315
400
400
500
500
630
630
630
800
800
4
4
6
10
16
16
20
25
35
35
50
63
80
100
100
160
200
200
250
315
315
400
500
630
630
-
4
4
4
6
10
10
16
16
25
35
50
50
63
80
100
125
160
200
250
250
315
400
400
500
630
-
1
1
1
1
2
2
4
4
4
4
6
6
10
16
16
16
20
20
25
35
35
50
50
50
63
63
80
80
100
100
125
125
160
160
200
250
250
250
315
315
315
400
500
500
500
630
630
630
1
1
1
1
2
2
2
2
4
4
6
6
10
10
10
10
16
16
20
25
25
35
35
50
50
50
63
63
80
80
100
100
125
160
200
200
200
250
250
315
315
400
400
400
500
500
630
630
2
2
2
4
4
6
6
10
16
16
25
25
35
35
50
63
63
80
125
125
160
200
200
250
315
400
500
500
2
2
2
2
4
4
4
6
10
10
16
20
25
35
35
50
63
63
100
125
125
160
200
250
315
400
400
500
motors with higher F.L.C., higher starting current and / or longer starting time, larger
short-circuit fuses are required.
The maximum admissible value is dependent on the switchgear respectively
thermal overload relay.
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500
9.8
13.8
16.0
20.0
24.0
34.0
56.0
80.0
100.0
135.0
-
4.9
6.9
8.0
10.0
12.0
17.0
28.0
40.0
50.0
68.0
88.0
110.0
136.0
176.0
216.0
-
2.5
3.5
4.0
5.0
6.0
8.5
14.0
21.0
26.0
34.0
44.0
55.0
68.0
88.0
108.0
-
4.0
4.8
6.4
9.0
11.8
16.6
26.4
38.0
48.0
72.0
94.0
118.0
138.0
180.0
226.0
-
4.4
6.4
8.4
12.0
13.6
19.2
30.4
44.0
56.0
84.0
108.0
136.0
160.0
208.0
260.0
-
2.0
2.4
3.2
4.5
5.9
8.3
13.2
19.0
24.0
36.0
47.0
59.0
69.0
90.0
113.0
133.0
166.0
218.0
-
2.2
3.2
4.2
6.0
6.8
9.6
15.2
22.0
28.0
42.0
54.0
68.0
80.0
104.0
130.0
145.0
192.0
248.0
312.0
360.0
480.0
602.0
-
1.0
1.2
1.6
2.3
3.0
4.2
6.6
9.0
12.0
18.0
23.0
29.0
35.0
45.0
56.0
67.0
83.0
109.0
135.0
156.0
208.0
-
1.1
1.6
2.1
3.0
3.4
4.8
7.6
11.0
14.0
21.0
27.0
34.0
40.0
52.0
65.0
77.0
96.0
124.0
156.0
180.0
240.0
302.0
361.0
414.0
477.0
590.0
0.8
1.0
1.3
1.8
2.4
3.3
5.3
8.0
10.0
14.0
19.0
24.0
28.0
36.0
45.0
53.0
66.0
87.0
108.0
125.0
167.0
-
0.9
1.3
1.7
2.4
2.7
3.9
6.1
9.0
11.0
17.0
22.0
27.0
32.0
41.0
52.0
62.0
77.0
99.0
125.0
144.0
192.0
242.0
289.0
336.0
382.0
472.0
1) Determine the motor current for 200V and 208V by increasing the values for 220-240V at 200V about 15% and for 208V about 10%.
D677E
43
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
K3-62
K3-74
V AC
690
690
690
690
690
690
690
690
690
690
at Ue = 690V AC
200
200
200
200
400
500
500
700
900
900
A
A
A
A
180
150
100
-
180
150
100
-
200
180
150
-
200
180
150
-
380
300
260
-
400
370
340
-
400
370
340
-
600
500
400
-
800
700
500
-
800
700
500
690V
25
25
32
32
50
65
80
110
120
130
220V
230V
240V
kW
kW
kW
9,5
9,9
10,4
9,5
9,9
10,4
12,2
12,7
13,3
12,2
12,7
13,3
19,0
19,9
20,8
24,7
25,9
27,0
30,4
31,8
33,2
41,9
43,8
45,7
45,7
47,7
49,8
49,5
51,7
54,0
380V
400V
415V
kW
kW
kW
16,4
17,3
17,9
16,4
17,3
17,9
21,0
22,1
23,0
21,0
22,1
23,0
32,9
34,6
35,9
42,7
45,0
46,7
52,6
55,4
57,4
72,3
76,1
79,0
78,9
83,0
86,2
85,5
90,0
93,3
440V
500V
660V
kW
kW
kW
19,0
21,6
28,5
19,0
21,6
28,5
24,4
27,7
36,5
24,4
27,7
36,5
38,1
43,3
57,1
49,5
56,2
74,2
60,9
69,2
91,3
83,7
95,2
125,6
91,3
103,8
137,0
99,0
112,5
148,4
690V
1000V
kW
kW
29,8
-
29,8
-
38,2
-
38,2
-
59,7
-
77,6
-
95,5
-
131,3
-
143,2
-
155,2
690V
25
25
32
32
40
55
65
90
100
110
220V
230V
240V
kW
kW
kW
9,5
9,9
10,4
9,5
9,9
10,4
12,2
12,7
13,3
12,2
12,7
13,3
15,2
15,9
16,6
20,9
21,9
22,8
24,7
25,9
27,0
34,3
35,8
37,4
38,1
39,8
41,5
41,9
43,8
45,7
380V
400V
415V
kW
kW
kW
16,4
17,3
17,9
16,4
17,3
17,9
21,0
22,1
23,0
21,0
22,1
23,0
26,3
27,7
28,7
36,2
38,1
39,5
42,7
45,0
46,7
59,2
62,3
64,6
65,7
69,2
71,8
72,3
76,1
79,0
440V
500V
660V
kW
kW
kW
19,0
21,6
28,5
19,0
21,6
28,5
24,4
27,7
36,5
24,4
27,7
36,5
30,4
34,6
45,7
41,9
47,6
62,8
49,5
56,2
74,2
68,5
77,9
102,8
76,1
86,5
114,2
83,7
95,2
125,6
690V
1000V
Minimum cross-section of conductor
at load with Ie (=Ith)
kW
kW
29,8
-
29,8
-
38,2
-
38,2
-
47,7
-
65,7
-
77,6
-
107,4
-
119,4
-
131,3
10
16
25
35
50
50
1)
mm
220V
230V
240V
A
A
A
12
11,5
11
15
14,5
14
18
18
18
22
22
22
24
24
24
30
30
32
40
40
40
50
50
50
63
62
62
74
74
74
380-400V
415V
440V
A
A
A
10
9
9
14
14
14
18
18
18
22
22
22
24
23
23
32
30
30
40
40
40
50
50
50
62
62
62
74
74
74
500V
660-690V
1000V
A
A
A
7
6,5
-
9
8,5
-
9
8,5
-
17,5
17
-
21
20
-
21
20
-
33
31
-
42
40
-
42
40
-
220-230V
240V
380-400V
kW
kW
kW
3
3
4
4
4
5,5
5
5
7,5
6
7
11
6
7
11
8,5
9
15
11
11,5
18,5
12,5
13,5
22
18,5
19
30
22
23
37
415V
440V
500V
kW
kW
kW
4,5
4,5
5,5
6
6
7,5
8,5
8,5
10
12
12
10
12
12
15
16
16
18,5
20
20
18,5
24
24
30
33
33
37
40
40
45
660-690V
1000V
kW
kW
5,5
-
7,5
-
10
-
10
-
15
-
18,5
-
18,5
-
30
-
37
-
45
-
9
8,5
1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
44
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type
K3-90
K3-115
K3-151
K3-176
K3-210
K3-260
K3-316
K3-450
K3-550
K3-700
K3-860
K3-1000 K3-1200
V~
1000
1000
1000
1000
1000
1000
1000
1000
1000
690
690
690
690
1100
1200
1500
2000
2100
2600
3200
4500
5500
7000
8600
10000
12000
A
A
A
A
950
850
600
-
1100
1000
600
-
1200
1200
1000
500
1500
1500
800
600
1600
1600
1200
700
2100
2100
1900
850
2600
2600
2300
1000
4500
4500
3200
-
5500
5500
4400
-
7000
7000
5600
-
8000
8000
6900
-
8000
8000
7000
-
10000
10000
8000
-
160
200
230
250
350
450
500
700
760
1000
1100
1200
1350
kW
kW
kW
60
63
66
76
79
83
87
91
95
95
99
103
133
139
145
171
179
187
190
199
207
266
279
291
289
302
315
381
398
415
419
438
457
457
478
498
514
537
561
kW
kW
kW
105
110
115
131
138
143
151
159
165
164
173
179
230
242
251
296
311
323
329
346
359
460
485
503
500
526
546
658
692
718
724
762
790
789
831
862
888
935
970
kW
kW
kW
121
138
182
152
173
228
175
199
262
190
216
285
266
303
400
342
389
514
381
453
571
533
606
800
579
658
868
762
866
1143
838
952
1257
914
1039
1371
1028
1169
1543
kW
kW
191
221
239
277
274
318
298
346
418
433
537
546
597
606
836
692
908
866
1195
-
1314
-
1434
-
1613
-
145
170
180
200
280
360
400
550
600
800
875
960
1080
kW
kW
kW
55
57
59
64
67
70
68
71
74
76
79
83
106
111
116
137
143
150
152
159
166
209
219
228
228
239
249
304
318
332
333
348
363
365
382
399
411
430
448
kW
kW
kW
95
100
104
111
117
122
118
124
129
131
138
143
184
193
201
237
249
259
263
277
287
362
381
395
395
415
431
526
554
575
575
606
628
631
665
690
710
748
776
kW
kW
kW
110
125
165
129
147
194
137
155
205
152
173
228
213
242
320
274
312
412
304
346
457
419
476
628
457
519
685
609
692
914
666
757
1000
731
831
1097
823
935
1234
kW
kW
173
166
202
187
215
277
239
346
334
388
430
499
478
554
657
692
717
866
956
-
1045
-
1147
-
1290
-
mm
95
120
95
120
240
2x150
A
A
A
90
90
90
115
115
115
150
150
150
175
175
175
210
210
210
260
260
260
315
315
315
450
450
450
550
550
550
700
700
700
860
860
860
1000
1000
1000
1200
1200
1200
A
A
A
90
90
90
115
115
115
150
150
150
175
175
175
210
210
210
260
260
260
315
315
315
450
450
450
550
550
550
700
700
700
860
860
860
1000
1000
1000
1200
1200
1200
A
A
A
60
58
58
60
58
58
150
120
60
175
140
70
210
150
85
260
180
100
315
240
125
450
400
200
550
500
250
700
630
-
860
700
-
1000
860
-
1200
1000
-
kW
kW
kW
25
27
45
33
35
55
40
45
75
50
55
90
60
65
110
75
80
132
90
100
160
132
140
250
175
185
300
225
235
400
280
290
500
325
335
580
390
400
680
kW
kW
kW
49
49
55
63
63
55
80
85
90
95
100
100
115
125
132
140
150
160
180
190
210
257
270
300
315
335
375
415
450
500
515
530
600
600
630
720
710
750
850
kW
kW
55
55
55
55
110
75
132
90
160
110
210
132
250
160
375
280
500
355
630
-
700
-
850
-
1000
-
D677E
45
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
K3-62
K3-74
12
11,5
11
15
14,5
14
18
18
18
18
18
18
24
24
24
30
30
32
40
40
40
50
50
50
63
62
62
63
62
62
10
9
9
14
14
14
18
18
18
18
18
18
24
23
23
32
30
30
40
37
37
50
45
45
62
60
55
62
60
55
12
9
8,5
-
16
9
8,5
-
16
9
8,5
17,5
17
17
-
21
20
20
-
21
20
20
-
33
31
31
-
42
40
40
-
42
40
40
-
380-400V
415V
440V
A
A
A
500V
660V
690V
1000V
A
A
A
A
9
7
6,5
-
220-230V
240V
380-400V
kW
kW
kW
3
3
4
4
4
5,5
5
5
7,5
5
5
7,5
6
7
11
8,5
9
15
11
11,5
18,5
12,5
13,5
22
18,5
19
30
18,5
19
30
415V
440V
500V
kW
kW
kW
4,5
4,5
5,5
6
6
7,5
8,5
8,5
10
8,5
8,5
10
12
12
15
16
16
18,5
20
20
18,5
24
24
30
33
33
37
33
33
37
660-690V
1000V
kW
kW
5,5
-
7,5
-
10
-
10
-
15
-
18,5
-
18,5
-
30
-
37
-
37
-
A
A
A
20
7
22,5
20
9
22,5
25
9
28
25
9
28
40
18
45
52
22
58
64
22
72
88
30
98
96
40
108
104
45
117
A
A
12
7
15
9
19
9
19
9
30
18
39
22
48
22
66
30
72
40
78
45
Mercury-vapour lamps2),
uncompensated
parallel compensated
A
A
22,5
7
25
9
28
9
28
9
45
18
58
22
72
22
99
30
108
40
117
45
20
20
25
25
40
52
64
88
96
104
12,5
12,5
12,5
12,5
25
31
31
43
56
56
1) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps)
2) High-pressure lamps
3) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps)
4) Current inrush approx. 16 x Ie
46
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
K3-90
K3-115
K3-151
K3-176
K3-210
A
A
A
85
85
85
98
98
98
55
55
55
63
63
63
85
85
85
100
100
100
120
120
120
150
150
150
180
180
180
230
230
230
280
280
280
340
340
340
400
400
400
A
A
A
85
85
85
85
85
85
55
55
55
63
63
63
85
85
85
100
100
100
120
120
120
150
150
150
180
180
180
230
230
230
280
280
280
340
340
340
400
400
400
A
A
A
A
85
60
57,5
-
85
60
57,5
-
kW
kW
kW
25
27
45
30
32
45
15
15,5
25
18,5
19
30
25
26
45
30
31
55
37
38
63
45
47
75
51
53
90
68
71
120
80
83
150
110
115
185
132
137
220
kW
kW
kW
49
49
55
49
49
55
25
30
25
33
34
30
45
48
55
55
55
65
65
67
75
80
85
100
100
100
110
132
132
150
160
160
185
200
200
220
230
230
257
kW
kW
55
-
55
-
25
-
30
-
55
-
65
-
75
-
100
-
110
-
150
-
185
-
220
-
257
-
A
A
A
100
55
112
120
70
144
120
85
120
140
100
140
180
130
180
220
160
220
280
200
280
360
300
360
450
360
450
570
460
570
700
550
700
850
660
850
1000
800
1000
A
A
85
55
90
70
95
75
110
85
140
110
180
140
230
170
300
260
380
300
490
400
610
480
750
580
890
700
A
A
112
55
144
70
120
75
140
85
180
110
220
140
280
170
360
260
450
300
570
400
700
480
850
580
1000
700
100
120
100
120
160
200
250
320
400
500
600
700
800
69
75
100
120
160
190
220
260
315
440
500
560
630
Type
D677E
K3-260
K3-316
K3-450
K3-550
K3-700
K3-860
K3-1000 K3-1200
47
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
400V
n
A
30
4,5
30
5,5
30
7,5
30
7,5
30
10,5
30
13,5
30
13,5
K3-62
K3-74
30
20
30
27
30
33
8
8,3
13,5
10,7
11,2
18,5
13
13,5
22,5
220-230V
240V
380-400V
kVA
kVA
kVA
1,8
1,9
3,1
2,2
2,3
3,8
3
3,1
5,2
3
3,1
5,2
4,2
4,3
7,3
5,4
5,6
9,3
5,4
5,6
9,3
415-440V
500V
660-690V
kVA
kVA
kVA
3,4
3,9
5,4
4,2
4,8
6,5
5,7
6,5
9
5,7
6,5
9
8
9
12,5
10,2
11,5
16
10,2
11,5
16
15
17
24
20,5
23
32
25
28
39
20
15,5
20
15,5
25
23
25
32
25
32
25
45
25
60
20
70
6
6,5
10
6
6,5
10
8,5
9,5
15
12
13
20
12
13
20
17
18,5
29
24
25
39
28
29
46
k
A
35
8
25
12
220-230V
240V
380-400V
kVAr
kVAr
kVAr
3
3,5
5
415-440V
500V
660-690V
kVAr
kVAr
kVAr
5,5
7
7
8
10
10
11
13
13
11
13
13
16
20
20
22
26
26
22
26
26
32
39
40
43
50
50
50
58
58
13
18
20
28
36
42
48
72
108 1)
220-230V
240V
380-400V
kVAr
kVAr
kVAr
2,9
3,1
5
5
5,4
9
7
7
12,5
7,5
8
13
11
11
20
14
14
25
16
17
27,5
20
20
33,3
28
28
50
33
36
75 1)
415-440V
500V
660-690V
1000V
kVAr
kVAr
kVAr
kVAr
5,5
6
8
-
9,5
11
15
-
13
15
20
-
14
17
22
-
22
25
33
-
27
30
41
-
30
36
48
-
36
40
55
-
53
60
82
-
75 1)
75
100
-
Switching of
reactive capacitor banks
Rated operational current Ie
Rated operational power
690V
4,5
5
7,5
1 pole 24V
60V
110V
220V
A
A
A
A
20
20
6
0,8
25
25
6
0,8
32
32
6
0,8
32
32
6
0,8
50
50
10
1,4
65
65
10
1,4
80
80
10
1,4
110
110
12
1,4
120
120
12
1,4
130
130
12
1,4
A
A
A
A
20
20
20
16
25
25
25
20
32
32
32
20
32
32
32
20
50
50
50
30
65
65
65
35
80
80
80
35
110
110
110
63
120
120
120
80
130
130
130
80
A
A
A
A
20
6
1,2
0,2
25
6
1,2
0,2
32
6
1,2
0,2
32
6
1,2
0,2
50
30
1,8
0,2
65
30
1,8
0,2
80
30
1,8
0,2
110
60
1,8
0,25
120
60
1,8
0,25
130
60
1,8
0,25
A
A
A
A
20
20
20
2,5
25
25
20
2,5
32
32
20
2,5
32
32
20
2,5
50
40
40
4
65
40
40
4
80
40
40
4
110
80
80
5
120
80
80
5
130
80
80
5
48
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
K3-90
K3-115
K3-151
K3-176
K3-210
n
A
30
38
30
50
30
65
30
80
30
90
30
120
30
142
30
203
30
248
30
315
30
390
30
450
30
540
kVA
kVA
kVA
15
15,5
26
20
20,5
34
25
27
45
30
33
55
34
37
60
45
50
80
54
59
95
77
80
140
95
100
170
120
130
210
148
160
270
170
185
310
200
220
370
kVA
kVA
kVA
29
33
45
38
43
60
46
55
56
57
69
69
63
75
100
85
100
135
100
120
160
145
170
200
175
210
250
220
270
320
280
330
350
320
380
500
380
460
600
k
A
20
87
20
100
20
120
20
155
25
195
20
225
20
255
20
300
20
370
20
440
20
520
20
680
20
760
kVAr
kVAr
kVAr
33
36
57
38
42
65
45
52
80
60
62
100
75
78
130
90
94
155
100
104
170
115
120
200
145
150
250
170
175
300
200
205
350
260
270
450
290
300
500
kVAr
kVAr
kVAr
60
70
70
70
80
80
95
100
100
110
130
130
135
170
170
165
194
194
175
220
220
210
260
260
260
320
320
310
380
380
360
450
450
465
590
590
520
660
660
115
144
115
140
200
225
250
330
420
550
600
680
760
kVAr
kVAr
kVAr
45
45
80
55
55
100
43
45
75
53
55
90
76
80
130
85
90
145
95
100
160
125
130
210
160
170
270
209
220
350
228
240
390
260
280
440
290
310
480
kVAr
kVAr
kVAr
kVAr
100
105
120
160
120
125
148
200
80
95
125
155
100
120
150
200
140
170
200
300
160
190
230
340
170
210
260
400
230
280
350
500
290
350
450
650
380
450
600
-
420
500
650
-
470
570
700
-
530
640
800
-
A
A
A
A
160
160
20
2
200
200
25
2,5
A
A
A
A
160
160
160
100
200
200
200
160
200
200
150
80
250
250
170
100
350
350
250
150
400
400
280
180
450
450
315
200
600
600
400
250
760
760
480
315
1000
1000
560
400
1100
1100
630
450
1200
1200
800
500
1350
1350
900
600
A
A
A
A
160
85
2
0,5
200
110
2,5
0,5
A
A
A
A
160
100
100
7
200
110
110
8
Type
D677E
K3-260
K3-316
K3-450
K3-550
K3-700
K3-860
K3-1000 K3-1200
49
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
open
enclosed
open
C
C
C
C
C
K3-62
K3-74
63
63
63
63
80
80
80
160
160
160
25
35
35
35
50
50
50
100
125
125
16
16
16
16
25
35
35
50
63
63
4 - 50
10 - 35
6 - 35
6+(1-6) / 4+(0,75-4)
2,5+(0,75-2,5) / 1,5+(0,75-1,5)
6+(1,5-4) / 4+(1-4)
2,5+(0,75-2,5) / 1,5+(0,75-1,5)
16+(2,5-16) / 10+(4-16)
6+(4-16) / 4+(2,5-16)
16+(2,5-6) / 10+(4-10)
6+(4-16) / 4+(2,5-16)
mm
flexible
mm
solid
flexible
AWG
AWG
18 - 10
18 - 10
16 - 10
14 - 4
12 - 10
10 - 0
solid
AWG
AWG
10+(16-10) / 12+(18-12)
14+(18-14) / 16+(18-16)
4+(18-12) / 6+(18-8)
8+(18-8) / 10+(18-12)
10+(12-10) / 12+12
flexible
10+(16-10) / 12+(18-12)
14+(18-14) / 16+(18-16)
10+(14-10) / 12+(18-12)
14+(18-14) / 16+(18-16)
1+(12-10) / 2+(8-12)
3+(12-8) / 4+(10-6)
10000
600
120
600
7000
600
120
600
7000
400
120
400
10
10
50
10
10
50
10
10
-
Frequency of operations z
Contactors without thermal overload relay
without load
AC3, Ie
AC4, Ie
DC3, Ie
Mechanical life
AC operated
DC operated
DC-solenoid operated (KG3)
1,5 - 25
2,5 - 16
1,5 - 16
solid or stranded
0,75 - 6
1-4
0,75 - 4
1/h
1/h
1/h
1/h
S x 106
S x 106
S x 106
10s-current
120s-current
at Ie/AC3 400V
A
A
W
mOhm
g
g
96
28
120
35
144
42
176
51
184
53
240
69
296
85
360
104
504
145
592
171
0,21
2,1
0,35
1,8
0,5
1,5
0,75
1,5
0,7
1,2
1,3
1,2
2
1,2
2,2
1
3,9
1
5,5
1
10
6
10
6
10
6
10
6
8
-
8
-
8
-
8
-
8
-
8
-
1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
50
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type
K3-90
K3-115
C
C
C
C
C
K3-151
K3-176
K3-210
K3-260
K3-316
K3-450
K3-550
K3-700
K3-860
K3-1000 K3-1200
250
250
250
315
400
450
500
630
630
800
1000
1000
1250
160
200
200
250
315
400
400
500
560
100
125
160
200
250
315
busbar
18 x 4
screw
M8
busbar
25 x 6
screw
M10
busbar
30 x 5
screw
M12
busbar
40 x 6
screw
M12
busbar
50 x 8
screw
M12
busbar
50 x 8
screw
M14
3000
300
120
300
1200
-
1200
-
1200
-
300
-
5
5
-
10
10
-
5
5
-
5
5
-
5 3)
5 3)
-
mm
mm
mm
0,5 - 95
0,5 - 70
0,5 - 70
10 - 120
25 - 95
10 - 95
mm
mm
mm
0,5 - 95 + 10 - 120
AWG
AWG
18 - 10
18 - 3/0
busbar
50 x 10
screw
2 x M12
0,5 - 70 + 25 - 95
8 - 4/0
AWG
AWG
18 - 3/0 + 8 - 4/0
1/h
1/h
1/h
1/h
S x 106
S x 106
S x 106
A
A
680
196
880
254
1200
346
1400
404
1800
520
2200
751
2600
900
3600
1039
4400
1270
5600
1617
6900
1992
8000
2309
9600
2771
4,8
0,6
7,9
0,5
9
0,4
11
0,35
8
0,18
11
0,16
14,9
0,15
26,3
33,3
49
59,2
60
72
7
5
7
5
mOhm
g
g
1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
2) With reduced control voltage range 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
3) After each 1x106 operations magnetic core and built-in auxiliary contact block must be changed
D677E
51
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Auxiliary Contacts
Rated insulation voltage Ui
690
40C
60C
A
A
16
12
220-240V
380-415V
440V
A
A
A
12
4
4
500V
660-690V
A
A
3
1
60V
110V
220V
A
A
A
8
1
0,1
1)
K3-62
For contactors with thermal overload relay the device with the smaller admissible control
fuse (contactor or thermal overload relay) determines the fuse.
gL (gG)
25
inrush
sealed
VA
VA
W
33-45
7-10
2,6-3
90-115
9-13
2,7-4
140-165
13-18
5,4-7
DC operated
double winding coil
inrush
sealed
W
W
75
2
140
2
200
6
DC solenoid operated
(KG3)
inrush
sealed
W
W
3
3
4
4
0,85-1,1
0,8-1,1
0,85-1,1
0,8-1,1
0,85-1,1
0,8-1,1
8-16
5-13
10-15
10-25
8-15
10-15
12-28
8-15
10-15
Control Circuit
Power consumption of coils
AC operated
make time
release time
arc duration
ms
ms
ms
8-12
8-13
10-15
10-20
10-15
10-15
12-23
10-18
10-15
DC solenoid operated
(KG3)
make time
release time
arc duration
ms
ms
ms
65 - 85
20 - 30 4)
10-15
65 - 85
20 - 30 4)
10-15
mm
mm
mm
0,75-6
1-4
0,75-4
solid
flexible
flexible with multicore cable end
Clamps per pole
mm
mm
mm
0,75-2,5
0,5-2,5
0,5-1,5
2
0,75-2,5
0,5-2,5
0,5-1,5
2
0,75-2,5
0,5-2,5
0,5-1,5
2
Auxiliary connector
solid
flexible
AWG
AWG
18 - 10
18 - 10
Magnet coil
solid
flexible
AWG
AWG
14 - 12
18 - 12
2
14 - 12
18 - 12
2
14 - 12
18 - 12
2
Cable cross-section
Auxiliary connector
solid
flexible
flexible with multicore cable end
Magnet coil
K3-74
1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request
2) Total breaking time = release time + arc duration
3) Values for delay of the release time of the make contact and the make time of the break contact will be increased, if magnet coils are protected against voltage
peaks (varistor, RC-unit, diode-unit)
4) with built-in coil suppressor
52
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type
K3-90
K3-115
K3-151
K3-176
K3-210
K3-260
K3-316
K3-450
K3-550
K3-700
K3-860
K3-1000 K3-1200
V~
690
690
690
A
A
-
10
-
10
-
10
-
A
A
A
3
2
1,5
3
2
1,5
3
2
1,5
A
A
1,5
1
1,5
1
1,5
1
A
A
A
1
0,5
1
0,5
1
0,5
10
10
10
VA
VA
W
165-220
2,5-5
2,5-5
350
5
5
360
5
5
800-950
9-11
9-11
1350-1600
21-25
21-25
2400
70
70
W
W
250
5
350
5
360
5
700-850
8-10
1300-1550
18-22
2100
60
W
W
0,85-1,1
0,8-1,1
0,85-1,1
0,85-1,1
0,85-1,1
0,85-1,1
0,85-1,1
0,85-1,1
0,85-1,1
0,85-1,1
ms
ms
ms
20-35
60-70
10-15
30-60
30-80
40-60
15-45
-
50-100
150-200 / 500-10001)
-
50-100
25-50
-
ms
ms
ms
20-35
60-70
10-15
30-60
30-80
-
40-60
15-45
-
ms
ms
ms
mm
mm
mm
0,75-2,5
0,75-2,5
-
0,75-2,5
0,75-2,5
-
mm
mm
mm
0,75-2,5
0,5-2,5
0,5-1,5
2
1-2,5
1-2,5
2
1-2,5
1-2,5
2
1-2,5
1-2,5
2
1-2,5
1-2,5
2
AWG
AWG
16 - 12
16 - 12
16 - 12
16 - 12
AWG
AWG
14 - 12
18 - 12
2
16 - 12
16 - 12
2
16 - 12
16 - 12
2
16 - 12
16 - 12
2
16 - 12
16 - 12
2
D677E
53
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
K2-09
K2-12
K2-16
K2-23
K2-30
K2-37
K2-45
K2-60
K85
K110
V~
690
690
690
690
690
690
690
690
750
750
at Ue = 690V AC
200
200
200
400
500
500
700
900
1100
1200
A
A
A
A
180
150
100
-
180
150
100
-
200
180
150
-
380
300
260
-
400
370
340
-
400
370
340
-
600
500
400
-
800
700
500
-
950
850
600
-
1100
1100
600
-
25
25
25
45
50
50
80
100
150
170
220V
230V
240V
kW
kW
kW
9,5
10
10,5
9,5
10
10,5
9,5
10
10,5
17
18
18,5
19
20
20,5
19
20
20,5
30
31,5
33
38
40
41
57
59
62
64
67
70
380V
400V
415V
kW
kW
kW
16,5
17,5
18
16,5
17,5
18
16,5
17,5
18
29,5
31
32
33
34,5
36
33
34,5
36
52
55
57
65
69
71
98
103
107
111
117
122
440V
500V
660V
kW
kW
kW
19
21,5
28,5
19
21,5
28,5
19
21,5
28,5
34
39
51
38
43
57
38
43
57
61
69
91
76
86
114
114
130
171
129
147
194
690V
kW
29,5
29,5
29,5
53,5
60
60
95
119
179
203
20
25
25
35
40
40
63
80
100
125
Type
1)
220V
230V
240V
kW
kW
kW
7,5
8
8
9,5
10
10,5
9,5
10
10,5
13
13,5
14,5
15
16
16,5
15
16
16,5
24
25
26
30
31,5
33
38
40
41
47
49
52
380V
400V
415V
kW
kW
kW
13
13,5
14
16,5
17,5
18
16,5
17,5
18
23
24
25
26
27,5
28,5
26
27,5
28,5
41
43
45
52
55
57
65
69
71
82
86
89
440V
500V
660V
kW
kW
kW
15
17
22,5
19
21,5
28,5
19
21,5
28,5
26,5
30
40
30
34
45
30
34
45
48
54
72
61
69
91
71
86
114
95
116
142
690V
kW
23,5
29,5
29,5
42
48
48
75
95
119
149
10
10
10
25
35
50
70
mm
220V
230V
240V
A
A
A
12
11,5
11
15
14,5
14
18
17,5
17
23
23
23
30
30
30
37
37
37
45
45
45
63
61
60
85
85
85
110
110
110
380-400V
415-440V
500V
A
A
A
10
9
9
12
12
12
16
16
16
23
23
23
30
30
30
37
37
30
45
45
45
60
60
55
85
85
85
110
110
110
660V
690V
A
A
7
6,5
9
8,5
9
8,5
17,5
17
21
20
21
20
33
31
42
40
60
58
60
58
220-230V
240V
380-400V
kW
kW
kW
3
3
4
4
4
5,5
5
5
7,5
6
7
11
8,5
9
15
11
11,5
18,5
12,5
13,5
22
18,5
19
30
25
27
45
33
35
55
415V
440V
500V
kW
kW
kW
4,5
4,5
5,5
6
6
7,5
8,5
8,5
10
12
12
15
16
16
18,5
20
20
18,5
24
24
30
33
33
37
49
49
55
63
63
55
660-690V
kW
5,5
7,5
7,5
15
18,5
18,5
30
37
55
55
1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
54
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
Type
K2-09
K2-12
K2-16
K2-23
K2-30
K2-37
K2-45
K2-60
K85
K110
12
11,5
11
15
14,5
14
16
16
16
23
23
23
30
30
30
37
37
37
45
45
45
63
61
60
85
85
85
98
98
98
10
9
9
12
12
12
16
16
16
23
21
21
30
28
28
37
37
37
45
45
45
60
60
60
85
85
85
85
85
85
12
9
8,5
16
9
8,5
17
13
12,5
23
17
16,5
23
17
16,5
45
33
31
55
42
40
85
60
57,5
85
60
57,5
380-400V
415V
440V
A
A
A
500V
660V
690V
A
A
A
9
7
6,5
220-230V
240V
380-400V
kW
kW
kW
3
3
4
4
4
5,5
5
5
7,5
6
7
11
8,5
9
15
11
11,5
18,5
12,5
13,5
22
18,5
19
30
25
27
45
30
32
45
415-440V
500V
660-690V
kW
kW
kW
4,5
5,5
5,5
6
7,5
7,5
8,5
10
7,5
11
11
11
15
15
15
20
15
15
24
30
30
33
37
37
49
55
55
49
55
55
A
A
A
20
7
22,5
20
9
22,5
20
9
22,5
35
18
41
40
22
45
40
22
45
65
30
72
85
40
90
100
55
112
120
70
144
A
A
12
7
15
9
15
9
28
18
30
22
30
22
50
30
62
40
85
55
90
70
A
A
22,5
7
25
9
25
9
41
18
45
22
45
22
72
30
90
40
112
55
144
70
20
20
20
35
40
40
65
85
100
120
12,5
12,5
12,5
25
31
31
43
56
69
75
n
A
30
4,5
30
5,5
30
7,5
30
10,5
30
13,5
30
13,5
30
20
30
27
30
38
30
50
8
8,3
13,5
10,7
11,2
18,5
15
15,5
26
20
20,5
34
20,5
23
32
29
33
45
38
43
60
400V
220-230V
240V
380-400V
kVA
kVA
kVA
1,8
1,9
3,1
2,2
2,3
3,8
3
3,1
5,2
4,2
4,3
7,3
5,4
5,6
9,3
5,4
5,6
9,3
415-440V
500V
660-690V
kVA
kVA
kVA
3,4
3,9
5,4
4,2
4,8
6,5
5,7
6,5
9
8
9
12,5
10,2
11,5
16
10,2
11,5
16
15
17
24
1 pole 24V
60V
110V
220V
A
A
A
A
20
20
6
0,8
25
25
6
0,8
25
25
6
0,8
45
45
10
1,4
50
50
10
1,4
50
50
10
1,4
80
80
12
1,4
100
100
12
1,4
150
150
20
2
170
170
25
2,5
A
A
A
A
20
20
20
16
25
25
25
20
25
25
25
20
45
45
45
30
50
50
50
35
50
50
50
35
80
80
80
63
100
100
100
80
150
150
150
100
170
170
170
160
1) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps)
2) High-pressure lamps
3) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps)
4) Current inrush approx. 16 x Ie
5) With central compensation pay attention to the current inrush (capacitor switching contactors)
D677E
55
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts
Type
A
A
A
A
20
6
1,2
0,2
25
6
1,2
0,2
25
6
1,2
0,2
45
30
1,8
0,2
50
30
1,8
0,2
50
30
1,8
0,2
80
60
1,8
0,25
100
60
1,8
0,25
150
85
2
0,5
170
110
2,5
0,5
A
A
A
A
20
20
20
2,5
25
25
20
2,5
25
25
20
2,5
45
40
40
4
50
40
40
4
50
40
40
4
80
80
80
5
100
80
80
5
150
100
100
7
170
110
110
8
open
enclosed
open
Storage
K2-09
K2-12
K2-16
K2-23
K2-30
K2-37
C
C
C
C
-50 to +90
K2-45
K2-60
K85
K110
63
63
63
80
80
80
160
160
250
250
25
35
35
50
50
50
100
125
160
200
16
16
16
25
35
35
50
63
100
125
0,75 - 4
0,75 - 2,5
0,5 - 2,5
2
1,5-10 + 1,5-6
1,5-6 + 1,5-4
1,5-6 + 1,5-4
1+1
4 - 35 2)
6 - 25 2)
4 - 25
1
10 - 70 2)
10 - 70 2)
10 - 35
1
AWG
AWG
14 - 10
18 - 10
2
14 - 10 + 14 - 10
14 - 8 + 14 - 10
1+1
10
10 - 2
1
10
6-0
1
1/h
1/h
1/h
1/h
10000
600
120
600
7000
600
120
600
7000
400
120
400
3000
300
120
300
S x 106
S x 106
10
10
10
10
10
10
5
5
solid
flexible
Frequency of operations z
Contactors without thermal overload relay
without load
AC3, Ie
AC4, Ie
DC3, Ie
Mechanical life
AC operated
DC operated with economy resistor
Short time current
10s-current
at Ie/AC3 400V
g
g
96
0,21
10
6
120
0,26
10
6
144
0,4
10
6
184
240
296
360
504
880
0,63
1,1
1,7
1,8
3,6
4,3
6,0
8
5
8
5
8
5
8
-
8
-
7
5
7
5
1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
2) Maximum cable cross-section with prepared conductor
56
680
D677E
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Auxiliary Contacts
Type
K2-16
K2-23
K2-30
K2-37
K2-45
K2-60
K85
K110
690
690
690
40C
60C
A
A
16
12
16
12
16
12
220-240V
380-415V
440V
A
A
A
12
4
4
12
4
4
12
6
6
500V
660-690V
A
A
3
1
3
1
4
2
60V
110V
220V
A
A
A
8
1
0,1
8
1
0,1
8
1
0,1
25
25
280-350 350-420
16-23 23-29
4-6
6-7,3
K2-12
V AC
1)
K2-09
inrush
sealed
VA
VA
W
33-45
7-10
2,6-3
90-115
9-13
2,7-4
140-165
13-18
5,4-7
DC operated
with economic circuit
inrush
sealed
W
W
75
2
140
2
200
6
0,85-1,1
0,8-1,1
0,85-1,1
0,8-1,1
0,85-1,1
0,8-1,1
0,85-1,1
0,8-1,1
170
2
320
4
make time
release time
arc duration
ms
ms
ms
8-16
5-13
10-15
10-25
8-15
10-15
12-28
8-15
10-15
13-30
8-15
10-15
DC operated
with AC magnet system
make time
release time
arc duration
ms
ms
ms
8-12
8-13
10-15
10-20
10-15
10-15
12-23
10-18
10-15
20-30
10-18
10-15
Cable cross-section
Auxiliary connector
solid
flexible
flexible with multicore cable end
mm
mm
mm
0,75-4
0,75-2,5
0,5-2,5
0,75-2,5
0,75-2,5
0,5-1,5
Magnet coil
mm
mm
mm
0,75-2,5
0,5-2,5
0,5-1,5
0,75-2,5
0,5-2,5
0,5-1,5
0,75-2,5
0,5-2,5
0,5-1,5
0,75-2,5
0,5-2,5
0,5-1,5
solid
flexible
flexible with multicore cable end
1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request
2) Total breaking time = release time + arc duration
3) Values for delay of the release time of the make contact and the make time of the break contact will be increased, if magnet coils are protected against voltage
peaks (varistor, RC-unit, diode-unit)
D677E
57
25
25
30
30
50
65
80
10
14
18
22
22
27
5
7
10
7
600V
120
130
34
44
52
66
5
10
10
10
7
10
15
15
10
15
20
20
10
20
25
25
10
25
30
30
1
3
3
3
2
3
3
5
380-415V
440-480V
550-600V
hp
hp
hp
5
5
7
5
7
10
10
10
15
10
15
20
10
15
20
15
20
25
20
25
30
25
30
40
30
40
50
40
50
50
18
22
22
27
34
44
52
66
3
7
7
10
3
7
10
10
5
10
15
15
7
15
15
15
10
15
20
15
20
25
20
25
30
20
25
30
27
37
5
10
10
10
14
110-120V
200V
220-240V
277V
hp
hp
hp
hp
1
1
2
1,5
2
3
380-415V
440-480V
550-600V
hp
hp
hp
3
3
3
3
5
5
5
5
7
110-120V
200V
220-240V
hp
hp
hp
440-480V
550-600V
hp
hp
110
hp
hp
hp
hp
600V
600V
1
2
3
3
3
5
7
7
K3-74
110-120V
200V
220-240V
277V
2
5
7
7
K3-62
1
3
3
5
1
3
5
5
2
5
5
7
5
7
10
5
7
10
7
10
15
15
22
2
3
5
10
10
15
20
20
25
25
30
22
27
44
52
66
90/5
90/5
125/5
175/5
200/5
250/5
300/5
3
5
7
3
7
7
A/kA
50/5
50/5
70/5
A/kA
V
45/100
600
50/100
600
70/100
600
A600
A600
A600
A600
K2-09
K2-12
K2-16
K2-23
K2-30
K2-45
K2-60
K85
K110
25
25
25
40
40
72
90
125
150
5
7
10
10
15
15
20
15
35
30
40
20
25
30
40
40
50
65
85
75
100
5
7
10
8
20
10
20
20
Type
110-120V
200V
220-240V
hp
hp
hp
1
2
3
2
3
3
2
3
5
440-480V
550-600V
hp
hp
5
7
7
10
10
15
110-120V
200V
220-240V
hp
hp
hp
1
1
2
2
1
2
3
3
5
7
15
20
1
3
3
2
3
5
3
5
7
A/kA
30/5
40/5
50/5
60/5
110/5
175/5
175/5
300/5
Rated voltage
600
600
600
600
600
600
600
600
600
A600
A600
A600
A600
A600
A600
A600
58
D677E
K3-115
K3-151
K3-176
K3-210
K3-260
K3-316
K3-450
K3-550
K3-700
K3-860
160
200
180
220
250
300
350
420
520
700
810
1215
85
99
125
150
190
240
300
300
400
550
700
1000
hp
hp
hp
hp
15
25
35
-
20
35
40
-
40
50
-
50
60
-
60
75
-
75
100
-
100
125
-
125
125
-
150
150
-
200
250
-
250
300
-
450
450
-
hp
hp
hp
50
65
85
60
75
100
100
125
125
150
150
200
200
250
250
300
250
250
350
350
500
500
600
600
900
900
86
103
125
150
hp
hp
hp
hp
8
15
20
20
10
20
25
25
15
25
-
25
30
-
40
-
50
-
50
-
hp
hp
hp
30
40
50
40
50
60
hp
hp
hp
hp
hp
300/10
300/10
300/10
350/10
400/18
500/18
500/18
1200/18
1200/18
2000/42
600
600
600
600
600
600
600
600
600
600
A600
A600
A600
A600
A600
Type
A/kA
A/kA
V
300/100 3) 300/100 3)
600
600
-
K3-1000 K3-1200
2000/30 2000/30
Type
K3-18NK
K3-24K
K3-32K
K3-50K
K3-62K
K3-74K
K3-90K
K3-115K
110-120V
200V
220-240V
kVAr
kVAr
kVAr
0-3,5
0-6
0-7
3-5,5
4,5-10
5,5-11
3-7
4,5-12,5
5,5-15
6,5-10
10-16,7
12,5-20
6,5-15
10-25
12,5-30
6,5-18 1)
10-32 1)
12,5-36 1)
10-24
17-40
20-47
10-28 2)
17-46 2)
20-56 2)
440-480V
550-600V
kVAr
kVAr
0-15
0-18
11,5-25
14,5-30
11,5-30
14,5-35
25-40
31-50
25-60
31-75
25-72 1)
31-90 1)
40-95
50-120
40-114 2)
50-143 2)
A/kA
70/5
90/5
125/5
200/5
250/5
300/5
300/10
300/10
A/kA
V
80/100
600
110/100
600
150/100
600
175/100
600
175/100
600
175/100
600
300/100 3)
600
300/100 3)
600
A600
1) Consider the max. thermal current of the contactor K3-74A: Ith 130A
2) Consider the min. cross-section of conductor at max. load
3) Class T and Class RK1
D677E
59
Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Contact Life
For selection of the suitable contactor-type according to supply voltage,
power rating and application (utilization category AC1, AC3 or AC4) use
contact life characteristic diagram.
For the most common supply voltages four scales of power ratings Pn are
provided for each utilization category.
Select contactor-type according to utilization category AC3 (breaking
current Ia = Ie) using the motor rating scales to the right, according to
utilization category AC4 (breaking current Ia = 6 x Ie) using the motor rating
scales to the left. 1)
Select contactor-type according to utilization category AC1 (breaking
current Ia = Ie/AC1) using the breaking current scale. 1)
Motor Rating
Pn /AC4
Motor Rating
Pn /AC3
M=
1+
%AC4
100
x(
AC3
-1
AC4
Breaking Current
Ia ( = Ie/AC1)
A
Millions of Operations
Motor Rating
Pn /AC4
Motor Rating
Pn /AC3
Breaking Current
Ia ( = Ie/AC1)
A
Millions of Operations
1) Pay attention to the approved rated values of the selected contactor according to the national approvals
60
D677E
Contactors
Utilization Categories
For easier choice of devices and in order to make the comparison
of different products simplier are utilization categories for contactors
and motor-starters according to IEC 947-4-1 and VDE 0660 Part 102, for
Type of
current
Alternating
Current
Category
Typical applications
AC1
Non-inductive or
slightly inductive loads
resistance furnaces
cos
all values
0,95
0,95
1,5 1,05
0,8
1,5 1,05
0,8
Slip-ring motors:
starting, switching off
all values
2,5
0,65
2,5
0,65
1,05
0,65
1,05
0,65
AC3
Squirrel-cage motors:
starting, switching off
motors during running
Ie
17A
17A< Ie 100A
Ie> 100A
6
6
6
1
1
1
0,65
0,35
0,35
1
1
1
0,17
0,17
0,17
0,65
0,35
0,35
10
10
10
1,05
1,05
1,05
0,45
0,45
0,35
8
8
8
1,05
1,05
1,05
0,45
0,45
0,35
AC4
Squirrel-cage motors:
starting, plugging,
inching
Ie
17A
17A< Ie 100A
Ie> 100A
6
6
6
1
1
1
0,65
0,35
0,35
6
6
6
1
1
1
0,65
0,35
0,35
12
12
12
1,05
1,05
1,05
0,45
0,45
0,35
10
10
10
1,05
1,05
1,05
0,45
0,45
0,35
AC5a
Switching of electric
discharge lamp controls
all values
1,05
0,45
1,05
0,45
AC5b
Switching of
incandescent lamps
all values
1,5 1,05
1,05
AC6a
Switching of
transformers
Ie 100A
Ie> 100A
4,5 1,05
4,5 1,05
AC6b
Switching of
capacitors
1,5 1,05
0,8
1,5 1,05
0,8
Ie 100A
Ie> 100A
8
8
1,05
1,05
0,45
0,35
6
6
1,05
1,05
0,45
0,35
AC2
AC7a
AC7b
Direct
Current
Rated
operational
current
all values
1)
0,45
0,35
3,6 1,05
3,6 1,05
2)
1)
0,45
0,35
2)
AC8a
Ie 100A
Ie> 100A
6
6
1,05
1,05
0,45
0,35
6
6
1,05
1,05
0,45
0,35
AC8b
Ie 100A
Ie> 100A
6
6
1,05
1,05
0,45
0,35
6
6
1,05
1,05
0,45
0,35
AC12
all values
0,9
0.9
AC13
Control of
solid state loads with
transformer isolation
all values
10
1,1
0,65
1,1 1,1
0,65
AC14
Control of
small electromagnetic loads
(72VA)
1,1
0,7
1,1
0,7
AC15
Control of
electromagnetic load
(>72VA)
10
0,7
0,4
10
1,1
0,3
10
1,1
0,3
Make
I/Ie
U/Ue
L/R
[ms]
Break
Ic/Ie Ur/Ue
L/R
[ms]
Make
I/Ie
U/Ue
L/R
[ms]
Break
Ic/Ie Ur/Ue
L/R
[ms]
DC1
Non-inductive or
slightly inductive loads
resistance furnaces
all values
1,5
1,05
1,5
1,05
DC3
Shunt-motors:
starting, plugging, inching
dynamic braking of d.c. motors
all values
2,5
2,5
1,05
2,5
1,05
2,5
DC5
Series-motors:
starting, plugging, inching
dynamic braking of d.c. motors
all values
2,5
7,5
2,5
7,5
1,05
1,05
15
DC6
Switching of
incandescent lamps
all values
1,5 1,05
1,05
1)
DC12
all values
DC13
Control of
electromagnets
all values
300
300
1,1 1,1
300
1,1 1,1
DC14
Control of
electromagnetic loads having
economy resistors in circuit
all values
10
1,1
15
1)
15
10
1,1
1
300
15
Ue Rated operational voltage, U Voltage before make, U r Recovery voltage, Ie Rated operational current, I Current make, Ic Current broken
1) Test with incandescent lamps
2) Test conditions according to standard
D677E
61
Accessories
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type
Rated insulation voltage Ui
V AC
1)
HN
HTN
HA
HB
HKT
HKA
HKF
HKB
K2-DK
K2-SK
K2-TP
K2-L 2)
690
690
690
690
690
690
690
690
690
10
6
10
6
25
20
10
6
10
-
16
-
26
-
10
-
10
6
3000
10
10
3000
10
3000
10
1200
1
3000
10
A
A
Frequency of operations z
Mechanical life
1/h
S x 106
0,5
0,5
1,5
0,5
220-240V
380-400V
440V
A
A
A
3
2
1,6
3
2
1,6
6
3
2
3
2
1,6
3
2
1,5
3
2
1,5
4
3
2
3
2
1,6
500V
660-690V
A
A
1,2
0,6
1,2
0,6
2
1
1,2
0,6
1,5
1
1,5
1
2
2
1
0,5
60V
110V
220V
A
A
A
2
0,4
0,1
2
0,4
0,1
8
1
0,1
2
0,4
0,1
0,5
0,2
0,5
0,2
2,5
1,5
0,2
2
0,4
0,1
20
20
25
20
10
10
10
10
mm
mm
mm
0,75-2,5
0,75-2,5
0,5-1,5
0,75-2,5
0,75-2,5
0,5-1,5
solid
flexible
AWG
AWG
14 - 12
18 - 12
14 - 12
18 - 12
0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12
0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12
0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12
0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12
1-2,5
0,75-2,5
0,75-2,5
14 - 12
18 - 12
0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12
14 - 12
18 - 12
HN
HTN
HA
HB..
HKT, HKA
HKF
K2-DK
K2-SK
K2-TP
K2-L 2)
10
10
16
10
10
10
V AC
600
600
600
600
600
600
600
A600
A600
A600
A600
A600
A600
Intermittent
duty
max.
1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.
2) Command duration min. 30ms, 10% duty cycle, max. 30 eec.
62
D677E
HKS11
HKA11
HN10U
HN01U
HB11
HTN10
HB02
HKF22
HTN01
HKT11
HB11, HB02:
Correct terminal marking
is given by mounting.
HKT22
Pneumatic timer
Indicator units
on-delayed
off-delayed
Voltage indicator
K2-TP..E
K2-TP..A
K2-ING
K2-INR
K2-UN
K2-UNR
red
red
Latch
Fuse holder
K2-L..
K2-F
Interface
with rectifier
K2-RF1
K2-RF3
K2-IM
red
black
Colours mentioned in
wiring diagram refer
to the outgoing
connection wires
of the device.
Regulation of switch position of aux. contakt block HKF22 for contactors K3-450 to K3-860
NO/NC overlapped
state of delivery
NO delayed
HKF22
NC
NC
NC
HKF22
NO
NO
NO
Contactor
position:
open
18
16 14 12 10
D677E
18
16 14 12 10
18
16 14 12 10
63
Contactors
Dimensions
AC operated
DC operated
K3-10N..
K3-14N..
K3-18N..
K3-22N..
KG3-10..
KG3-14..
KG3-18..
KG3-22..
K3-24..
K3-32..
K3-40..
KG3-24..
KG3-32..
KG3-40..
K3-50..
K3-62..
K3-74..
K3-50..=
K3-62..=
K3-74..=
AC and DC operated
K3-90..
K3-115..
64
D677E
Contactors
Dimensions
AC operated, DC operated
K3-151..
K3-176..
HKA11
HKT..
K3-210..
K3-260..
K3-316..
HKA11
HKT..
K3-450..
K3-550..
Typ
K3-450
K3-550
D677E
40
40
10,5
12,5
4 233 206
6 258 228
65
Contactors
Dimensions
AC and DC operated
K3-700..
K3-860..
Typ
K3-700
K3-860
K3-1000..
K3-1200..
1)
K3-24K..
K3-32K..
K3-50K..
K3-62K..
K3-74K..
K3-90K..
K3-115K..
66
13 310 277
15 361 325
D677E
Contactors
Dimensions
Contactors DC operated
K3-10N..=
K3-14N..=
K3-18N..=
K3-22N..=
K3-24..=
K3-32..=
K3-40..=
K2-23A00-40
K2-30A00-40
K2-37A00-40
K3-116A00-40
K3-151A00-40
K3-176A00-40
D677E
67
Contactors
Dimensions Accessories
Aux. cont. blocks, terminal blocks
HN10, HN01 K2-SK, K2-DK
HB11, HB02
NP175
NP350
223
223
148
148
26
26
52
52
98
98
5
5
122
122
M8
M8
NP325
NP500
NP760
262
294
294
148
220
220
26
53
53
55
72
72
116
138
138
5
5
5
122
152
152
M10
M12
M12
NP501
NP1000
348
348
220
220
53
53
73
73
145
145
5
8
152
152
M12
M12
NP1001
410
220
53
110
157
152
M12
Pneumatic timer
K2-TE..
K2-TA..
K2-TP
68
D677E
Contactors
Dimensions Accessories
Mechanical interlocks
Type
Contactor 1
LG10889
LG10889
LG10889
Contactor 2
A1
A2
A3
B1
B2
C1
C2
C3
K3-07 to K3-40
K3-07 to K3-40
KG3-07 to KG3-22 KG3-07 to KG3-22
KG3-24 to KG3-40 KG3-22 to KG3-40
45
45
45
7
7
7
45
45
45
50
80
80
50
50
50
35
35
35
17
17
17
35
35
35
4,5
4,5
4,5
4,5
4,5
4,5
LG10890
LG10890
K3-50 to K3-74
K3-50 to K3-74
K3-24 to K3-40
K3-50 to K3-74
60
60
12
12
55
60
100
100
65
100
50
50
22
22
45
50
5,5
5,5
4,5
5,5
LG11478
90
12
90
100
100
75
27
75
5,5
5,5
LG8511
K65 - K110
K65 - K110
90
12
90
100
100
75
27
75
LG11223H
LG11223H
K3-151, -176
K3-116,-151, -176
K3-151, -176
K3-116,-151, -176
110
147
30
30
110
147
130
130
130
130
100
135
40
42
100
135
6
6
6
6
3-pole contactor
4-pole contactor
LG11223H
LG11223H
145
193
30
30
145
193
160
160
160
160
120
170
55
55
120
170
6
6
6
6
3-pole contactor
4-pole contactor
LG10400H
LG10402H
K3-450, K3-550
K3-700, -860
K3-450, K3-550
K3-700, -860
220
280
42
32
220
280
220
280
220
280
110
175
152
137
110
175
9
11
9
11
LG10403H
LG10399H
LG10401H
K3-1000, -1200
K3-450, -550
K3-700, -860
K3-1000, -1200
K3-700, -860
K3-1000, -1200
334
220
280
46
37
73
334
280
334
380
220
280
380
280
380
120
110
175
260 120
144,5 175
232,5 120
LG10400V, LG10402V
LG10399V
Type
Contactor 1
Contactor 2
LG10400V
LG10402V
K3-315 - K3-550
K3-700, -860
LG10403V
LG10399V
LG10401V
K3-1000, -1200
K3-450, -550
K3-700, -860
D677E
D1
D2
13,5 13,5
9
11
11
13,5
LG10403V, LG10401V
A1
B1
B2
B3
C1
C2
C3
C4
D1
D2
K3-315 - K3-550
K3-700, -860
250
302
134
162
220
280
94
200
220
280
110
175
110
175
9
11
9
11
K3-1000, -1200
K3-700, -860
K3-1000, -1200
302
-
380
220
280
280
150
240
380
280
380
120
110
175
120
175
120
51
-
13,5 13,5
74,5
9
11
11
13,5
69
Contactors
Dimensions Accessories
Latch
K2-L..
A
40
86
Indicator units
Fuse holder
K2-ING, K2-INR
K2-UN, K2-UNR
K2-RF
K2-RF1
K2-RF3
70
D677E
Contactors
Dimensions Accessories
Interface
Snap-on adapter
K2-IM
K2-SM
Suppressor units
K2-E..
VG-K2/..
Marking systems
marking label
P487-1 or P245-.
D677E
RC-K3 ..
71
Contactors
Position of terminals
K3-10ND10
K3-14ND10
K3-18ND10
K3-22ND10
K3-18NK10
K3-10ND01
K3-14ND01
K3-18ND01
K3-22ND01
K3-18NK01
K3-24A00, K3-24K00
K3-32A00, K3-32K00
K3-40A00
K3-90A00
K3-115A00
K3-151A00
K3-176A00
K3-210A00
K3-260A00
K3-316A00
K3-151A00-40
K3-176A00-40
K3-210A00-40
K3-260A00-40
K3-316A00-40
KG3-10A10
KG3-14A10
KG3-18A10
KG3-22A10
KG3-10A01
KG3-14A01
KG3-18A01
KG3-22A01
KG3-10A00-40
KG3-14A00-40
KG3-18A00-40
KG3-22A00-40
K3-10ND10=
K3-14ND10=
K3-18ND10=
K3-22ND10=
K3-10ND01=
K3-14ND01=
K3-18ND01=
K3-22ND01=
K3-24A00=
K3-32A00=
K3-40A00=
K3-50A00, K3-50K00
K3-62A00, K3-62K00
K3-74A00, K3-74K00
K3-50A00=
K3-62A00=
K3-74A00=
K3-10NA00-40
K3-14NA00-40
K3-18NA00-40
K3-22NA00-40
K2-23A00-40 bis
K2-60A00-40
K3-450A22
K3-550A22
K3-700A22
K3-860A22
K85A22
K110A22
K3-1000A12
K3-1200A12
KG3-24A00
KG3-32A00
KG3-40A00
K85A21=
K110A21=
K3-1000A12=
K3-1200A12=
D677E
Motor Starters
D677E
74
76
76
Accessories
77
Reversing Contactors
78
80
Technical Data
82
Wiring Diagrams
85
Dimensions
89
73
AC Operated
660V
690V
kW
Rated
Current
Wired to accept
Overload Relay
AC3
400V
A
Relay
7,5
11
16
15
18,5
15
30
22
30
22
45
30
37
30
60
45
55
45
85
55
75
55
109
75
90
90
150
110
132
110
205
132
160
160
240
160
180
180
300
230
400
Type
U3/32
U12/16E K3
U3/42
U3/74
U85
U180
Coil voltage 1)
220-240V 50Hz
380-415V 50Hz
Type
Pack
pcs.
Weight
kg/pc.
K3NY15 . . .
0,9
K3NY26 . . .
0,9
K3Y40 . . .
1,4
K3Y52 . . .
1,8
K3Y80 . . .
3,5
K3Y100 . . .
3,7
K3Y140 . . .
6,6
K3Y200 . . .
K3Y240 . . .
15
K3Y300 . . .
15
Star-delta starters are wired to accept thermal overload relay. The thermal overload relay has to be ordered separately.
For full load current setting use the YD-dial of thermal overload relay.
Ordering Example: Star-Delta Starter, open type, rated AC3 at 400V 205A
rated control voltage 230V 50Hz - Order Type: K3Y200 230 + U85 120
Type
Pack Weight
pcs. kg/pc.
Wiring Diagram
U12/16E 6 K3
U12/16E 9 K3
U12/16E 11 K3
1
1
1
0,10
0,10
0,10
18
23
U12/16E 14 K3
U12/16E 18 K3
1
1
0,10
0,10
- 24
- 31
manual eset
U3/32 6
U3/32 9
U3/32 11
1
1
1
0,14
0,14
0,14
18
23
30
- 24
- 31
- 41
U3/32 14
U3/32 18
U3/32 24
1
1
1
0,14
0,14
0,14
40
- 55
U3/32 32
0,14
U3/42 20
U3/42 28
U3/42 42
1
1
1
0,30
0,30
0,30
manual and
auto reset
- 35
- 48
- 73
manual and
auto reset
1) Coil voltage range and other coil voltages see page 82
74
D677E
Star
Contactor
Type
Auxiliary Contacts
Built-in for use
on Contactor
Line Delta Star
K1
K2
K3
NO/NCNO/NCNO/NC
K1
Type
K2
Type
K3
Type
K3-10ND01
+ HN10
K3-10ND01
LG10889
K3NY-VB10
K3-18ND01
+ HN10
Y9A
LG10889
K3NY-VB10
K3-24A00
+ 2HN10 + HN01
Y9A
LG10889
K3Y-VB24
K3-32A00
+ HN01
K3-24A00
+ 2HN10 + HN01
Y9A
LG10889
K3Y-VB24
K3-50A00
+ HN01 + HN10
K3-50A00
+ HN01
K3-32A00
+ 2HN10 + HN01
Y9A
LG10890
K3-62A00
+ HN01 + HN10
K3-62A00
+ HN01
K3-50A00
+ 2HN10 + HN01
Y9A
LG10890
K3-90A00
+ HN01 + HN10
K3-90A00
+ HN01
K3-90A00
+ 2HN10 + HN01
Y9AL
LG11478
K3-115A00
+ HN01 + HN10
K3-115A00
+ HN01
K3-90A00
+ 2HN10 + HN01
Y9AL
LG11478
K3-151A00
+ HKT11
K3-151A00
+ HKT11
K3-151A00
+ HKT22
Y9AL
LG11223H
1/-
-/1
K3-176A00
+ HKT11
K3-176A00
+ HKT11
K3-151A00
+ HKT22
Y9AL
LG11223H
1/-
-/1
Electronic Mechanical
Timer
Interlock
between
K4
K2 and K3
Type
Type
Star-Delta
Starter
Connector
K3-10ND10
+ HN10 + HN01
Y9A
K3-18ND01
K3-14ND10
+ HN10 + HN01
K3-24A00
+ HN10 + HN01
K3-24A00
+ HN01
K3-32A00
+ HN10 + HN01
Applications
Time setting
The star-delta starting method is only practicable in such cases where the
motor windings are connected in delta configuration for normal operation
and the torque which is needed during the starting period is not higher
than approx. 30% of the rated torque. The starting current drawn from the
line will be approx. 2 to 2,7 times the rated motor current.
Type
Pack Weight
pcs. kg/pc.
Wiring Diagram
- 48
- 73
- 90
U3/74 28
U3/74 42
U3/74 52
1
1
1
0,40
0,40
0,40
90
-112
U3/74 65
0,40
1
1
0,90
0,90
1,5
manual and
auto reset
-156
-207
U85 90
U85 120
manual eset
U180 180
manual and
auto reset
D677E
75
AC Operated
Rated
Current
660V
690V
kW
Optional
Extras
Wired
to accept
Overload
Relay
AC3
400V
A
Type
230
400
Type
Coil voltage 1)
220-240V 50Hz
380-415V 50Hz
Pack
pcs.
Weight
kg/pc.
18,5
15
30
ST
U3/32
K3NY26P . . .
1,8
22
30
22
45
ST, H
U3/42
K3Y40P . . .
3,8
30
37
30
60
ST, H
K3Y52P . . .
4,2
45
55
45
85
ST, H
K3Y80P . . .
5,9
55
75
55
109
ST, H
K3Y100P . . .
8,7
U3/74
18,5
15
30
ST, H
U3/32
K3NY26B . . .
4,8
22
30
22
45
ST, H
U3/42
K3Y40B . . .
4,8
30
37
30
60
ST, H
K3Y52B . . .
5,2
45
55
45
85
ST, H
K3Y80B . . .
15
55
75
55
109
ST, H
K3Y100B . . .
15
75
90
90
150
ST, H
K3Y140B . . .
22
110
132
110
205
ST, H
K3Y200B . . .
22
U3/74
U85
<250V (1 piece)
>250V (2 pieces)
. . . . . . .W . . .
. . . . . . .ST . . .
. . . . . . .ST . . .
. . . . . . .H . . .
Ordering Example: Star-Delta Starter, steel sheet enclosed, with selector switch and run hour meter
rated AC3 at 400V 82A, rated control voltage 230V 50Hz - Order Type: K3Y80BWH 230 + U3/74 52
accept
Overload Relay
Type
Pack
pcs.
Weight
kg/pc.
U3/32
U3/42, U3/32
K3Y26P-G3
K3Y40/52P-G3
1
1
1,0
2,4
U3/32
U3/42, U3/32
K3Y26B-G3
K3Y40/52B-G3
1
1
3,4
3,4
Plastic IP65
K3Y15, K3Y26
K3Y40, K3Y52
76
D677E
Type
K3NY15, K3NY26
K3Y40, K3Y52
K3NY-VB10
K3Y-VB24
Pack
pcs.
1
1
Weight
kg/pc.
0,02
0,03
Additional Terminals
For Star-Delta Starter Types
Line Conn.
Motor Conn.
Line Contactor
Overload Relay
Cable
cross-section
mm
Type
Pack
Weight
pcs.
kg/pc.
U12/16
0,009
LG7559
0,052
4 - 35 strand.
4 - 25 flex.
Type
24 - 60V AC
110 - 415V AC
1 - 20
1 - 20
20 - 25
20 - 25
6
6
4
4
Y9A 60
Y9A 415
1
1
0,075
0,075
24 - 60V~
110 - 415V~
1 - 20
1 - 20
40 - 80
40 - 80
6
6
4
4
Y9AL 60
Y9AL 415
1
1
0,075
0,075
1%
2s
4A gl (gG)
Power consumption at
24V
60V
220-240V
380-415V
Pack
Weight
pcs.
kg/pc.
0,2VA
5VA
2VA
7VA
Mounting Bar
Specification
Type
LG7735
Pack
pcs.
10
Weight
kg/pc.
0,09
D677E
77
Rated
Current
660V
690V
kW
AC3
400V
A
5,5
10
7,5
18
AC Operated
Coil voltage 1)
110V 50Hz
220-240V 50Hz
380-415 50Hz
Pack
pcs.
Wired
to accept
Overload
Relay
page 102
Type
Type
U3/32
U12/16E K3
K3NWU10 . . .
0,6
K3NWU18 . . .
0,6
K3WU24 . . .
1,2
K3WU32 . . .
1,4
K3WU50 . . .
2,5
110
230
400
Weight>
kg/pc.
Open Type
4
7,5
5,5
10
11
15
15
24
15
18,5
18,5
32
22
30
30
50
30
37
37
62
K3WU62 . . .
2,5
37
45
45
74
K3WU74 . . .
2,5
K3WU10B . . .
3,9
K3WU18B . . .
4,1
K3WU24B . . .
4,5
K3WU32B . . .
4,7
K3WU50B . . .
7,1
K3WU62B . . .
7,1
U3/42
U3/74
5,5
10
5,5
10
7,5
18
11
15
15
24
15
18,5
18,5
32
22
30
30
50
30
37
37
62
U3/32
U3/42
U3/74
Type
K3WU10, K3WU18
K3WU24, K3WU32
K3NW-VB10
K3W-VB24
Pack
pcs.
1
1
D677E
Weight
kg/pc.
0,02
0,025
Mechanical
Interlock
Reversing
Starter
Connector
Auxiliary Contacts
Built-in for use
on Contactor
K1
Type
K2
Type
Type
Type
K1
NO/NC
K2
NO/NC
K1
K2
HN.. or HA..
K3-10ND10
+ HN01
K3-10ND10
+ HN01
LG10889
K3NW-VB10
K3-18ND10
+ HN01
K3-18ND10
+ HN01
LG10889
K3NW-VB10
K3-24A00
+ HN10 + HN01
K3-24A00
+ HN10 + HN01
LG10889
K3W-VB24
K3-32A00
+ HN10 + HN01
K3-32A00
+ HN10 + HN01
LG10889
K3W-VB24
K3-50A00
+ HN10 + HN01
K3-50A00
+ HN10 + HN01
LG10890
K3-62A00
+ HN10 + HN01
K3-62A00
+ HN10 + HN01
LG10890
K3-74A00
+ HN10 + HN01
K3-74A00
+ HN10 + HN01
LG10890
K3-10A10
+ HN01
K3-10A10
+ HN01
LG10889
K3W-VB10
K3-18A10
+ HN01
K3-18A10
+ HN01
LG10889
K3W-VB10
K3-24A00
+ HN10 + HN01
K3-24A00
+ HN10 + HN01
LG10889
K3W-VB24
K3-32A00
+ HN10 + HN01
K3-32A00
+ HN10 + HN01
LG10889
K3W-VB24
K3-50A00
+ HN10 + HN01
K3-50A00
+ HN10 + HN01
LG10890
K3-62A00
+ HN10 + HN01
K3-62A00
+ HN10 + HN01
LG10890
D677E
79
AC Operated
Rated
Current
660V
690V
kW
AC3
400V
A
5,5
10
Coil voltage 1)
220-240V 50Hz
380-415V 50Hz
Wired
to accept
Overload
Relay
page 102
Type
Type
U3/32
U12/16E K3
KNW3-10 . . .
0,6
KNW3-18 . . .
0,6
KW3-24 . . .
1,2
230
400
Pack
pcs.
Weight>
kg/pc.
Open Type
4
7,5
5,5
10
10
18
11
15
15
24
15
18,5
18,5
32
KW3-32 . . .
1,4
18,5
18,5
18,5
40
KW3-40 . . .
1,4
U3/42
AC Operated
Ratings
AC3 at
380V
400V
415V
500V
kW
kW
Rated
Current
660V
690V
kW
AC3
400V
A
Wired
to accept
Overload
Relay
page 102
Type
Type
230
400
Coil voltage 1)
220-240V 50Hz
380-415V 50Hz
Pack
pcs.
Weight>
kg/pc.
Open Type
7,5
10
10
18
11
15
15
24
15
18,5
18,5
32
22
30
30
50
30
37
37
62
K3NPU18 . . .
1,0
K3NPU24 . . .
1,5
2 x U3/32
K3PU32 . . .
1,9
2 x U3/74
K3PU50 . . .
3,9
K3PU62 . . .
3,9
K3NPU18B . . .
1,0
2 x U3/32
2 x U12/16E K3
10
7,5
18
2x U3/32
11
15
15
24
K3NPU24B . . .
1,5
15
18,5
18,5
32
K3PU32B . . .
1,9
D677E
Mechanical
Interlock
Auxiliary Contacts
Built-in for use
on Contactor
K1
Type
K2
Type
Type
K1
NO/NC
K2
NO/NC
K1
K2
HN.. or HA..
K3-10ND01
K3-10ND01
LG10889
K3-18ND01
K3-18ND01
LG10889
K3-24A00
+ HN01
K3-24A00
+ HN01
LG10889
K3-32A00
+ HN01
K3-32A00
+ HN01
LG10889
K3-40A00
+ HN01
K3-40A00
+ HN01
LG10890
Star
Contactor
K1
Type
K2
Type
K3
Type
K3-18ND01
+ 2 x HN10
K3-18ND01
+ HN10
K3-14ND10
K3-24A00
+ HN01 + 2 x HN10
K3-24A00
+ HN01 + HN10
K3-18ND10
K3-32A00
+ HN01 + 2 x HN10
K3-32A00
+ HN01 + HN10
K3-24A00
+ HN10
K3-50A00
+ HN01 + 2 x HN10
K3-50A00
+ HN01 + HN10
K3-32A00
+ HN10
K3-62A00
+ HN01 + 2 x HN10
K3-62A00
+ HN01 + HN10
K3-50A00
+ HN10
K3-18ND01
+ 2 x HN10
K3-18ND01
+ HN10
K3-14ND10
K3-24A00
+ HN01 + 2 x HN10
K3-24A00
+ HN01 + HN10
K3-18ND10
K3-32A00
+ HN01 + 2 x HN10
K3-32A00
+ HN01 + HN10
K3-24A00
+ HN10
D677E
81
Star-Delta Starters
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Type
K3NY15 K3NY26
K3Y40
K3Y52
K3Y80
690
690
690
Main Contacts
Rated insulation voltage Ui 1)
V AC
1/h
s
A
A
A
16
16
16
30
30
30
45
45
45
60
60
60
85
85
85
415-440V
500V
660-690V
A
A
A
15
15
13
30
30
17
45
45
30
60
60
36
690
690
690
690
690
690
109
109
109
150
150
150
205
205
205
240
240
240
300
300
300
85
85
57
109
95
72
150
150
103
205
205
118
240
190
147
300
240
180
15
20 (Type K3YL ... 60)
kW
kW
kW
4
5,5
7,5
7,5
11
15
11
15
22
15
18,5
30
22
22
45
30
30
55
45
45
75
55
55
110
75
75
132
90
90
160
415-440V
500V
660-690V
kW
kW
kW
7,5
7,5
11
15
18,5
15
22
30
22
30
37
30
45
55
45
55
75
55
75
90
90
110
132
110
140
132
132
170
180
180
Cable cross-sections
Line
solid or stranded
flexible
lexible with multicore cable end
mm
mm
mm
1,5 - 6 2)
1,5 - 4 2)
1,5 - 4 2)
1,5 - 16
1,5 - 16
1,5 - 16
10 - 70 3)
16 - 50 3)
10 - 35
10 - 120
10 - 95
10 - 95
busbar
18x5
M8
mm
mm
mm
1,5 - 6
1,5 - 4
1,5 - 4
1,5 - 16
1,5 - 16
1,5 - 16
4 - 35 3)
6 - 25 3)
4 - 25
10 - 120
10 - 95
10 - 95
busbar
18x5
M8
55
20
6
130
26
8
183
36
14
560
10
10
700
10
10
Motor
solid or stranded
flexible
lexible with multicore cable end
Coil Voltage Ranges and Non Standard Voltages for Star-Delta Starters
K3NY15.. to K3Y100..
Suffix to
Star-Delta Starter
type
e.g. K3Y80 400
K3Y140, to K3Y300..
Rated Control Voltage Us
range for 50Hz
range for 60Hz
min.
max.
min.
max.
V
V
V
V
Suffix to
Star-Delta Starter
type
e.g. K3Y300 230
for DC
V
24
42
110
24
42
100
24
47
110
24
47
110
27
52
122
24
48
110
24
48
110
24
48
120
24
48
110
24
48
120
24
48
110
180
230
400
180
220
380
210
240
415
200
230
400
240
264
415
230
400
220
380
240
415
220
380
240
415
220
-
82
D677E
Reversing Starters
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Type
K3NWU10 K3NWU18
K3WU24
K3WU32
K3WU50
K3WU62
K3WU74
690
690
690
690
690
690
12
11,5
11
18
18
18
23
24
24
30
32
32
45
50
50
63
62
62
74
74
10
9
9
6,5
18
18
16
8,5
24
23
23
17
32
30
30
20
50
50
45
31
62
62
60
40
74
74
74
40
220-230V kW
240V kW
380-400V kW
3
3
4
5
5
7,5
6
7
11
8,5
9
15
12,5
13,5
22
18,5
19
30
23
37
415-440V kW
500V kW
660-690V kW
4,5
5,5
5,5
8,5
10
10
12
15
15
16
18,5
18,5
24
30
30
33
37
37
40
45
45
Main Contacts
Rated insulation voltage Ui 1)
V AC
A
A
A
A
690
Cable cross-sections
Line
solid or stranded mm
flexible mm
flexible with multicore cable end mm
Cables per clamp
0,75 - 6
1-4
0,75 - 4
1
1,5 - 25
2,5 - 16
1,5 - 16
1
4 - 50
6 - 35
6 - 35
1
33 - 45
7 - 10
2,6 - 3
90 - 115
9 - 13
2,7 - 4
140 - 185
13 - 18
5,4 - 7
Type
110-120V
200V
220-240V
277V
KNW3-10
hp
hp
hp
hp
1
3
3
3
380-415V hp
440-480V hp
550-600V hp
5
5
7
A/kA
Rated voltage
solid AWG
flexible AWG
KNW3-18
2
5
7
7
KW3-24
KW3-32
KW3-40
5
7
10
7
5
10
10
10
7
10
15
15
10
10
15
10
15
20
15
20
25
20
25
30
30/5
50/5
90/5
125/5
175/5
600
600
600
600
600
A600
A600
A600
A600
A600
18 - 10
18 - 10
1
16 - 10
14 - 4
1
1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.
D677E
83
V AC
K3NPU18
K3NPU24
K3PU32
K3PU50
K3PU62
690
690
690
690
690
18
17,5
17
23
23
23
30
30
30
45
45
45
63
60
60
16
16
16
23
23
23
30
30
30
45
45
45
60
60
60
16
9
8,5
23
17,5
17
30
21
20
45
33
31
55
42
40
220-230V kW
240V kW
380-400V kW
5
5
7,5
6
7
11
8,5
9
15
12,5
13,5
22
18,5
19
30
415-440V kW
500V kW
660-690V kW
8,5
10
7,5
12
15
15
16
18,5
18,5
24
30
30
33
37
37
Cable cross-sections
Line
solid or stranded mm
flexible mm
flexible with multicore cable end mm
cables per clamp
Power consumption of the combination
inrush and change-over VA
sealed VA
W
0,75 - 6
1-4
0,75 - 4
1
1,5 - 25
2,5 - 16
1,5 - 16
1
4 - 50
6 - 35
6 - 35
1
55
20
6
128
26
8
178
31
11
1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.
84
D677E
Star-Delta Starters
Wiring Diagrams Main Circuit
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and circuits as broken lines are not included.
K3NY15 to K3Y100
with thermal overload relay U3/.. or U12/16
K3Y140 to K3Y300
with thermal overload relay U85 or U180
K3Y15 to K3Y52
operating with push buttons
K3Y80 to K3Y200
operating with control switch
K3Y80 to K3Y200
operating with push buttons
K3Y240 to K3Y300
operating with control switch
K3Y240 to K3Y300
operating with push buttons
D677E
85
Star-Delta Starters
Wiring Diagrams Main Circuit
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and control circuits as broken lines are not included.
K3YL..
Typical circuit diagram
86
D677E
Reversing Contactors
Wiring Diagrams Main Circuit
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and control circuits as broken lines are not included.
K3NWU10 to K3WU74
with thermal overload relay U3/32, U3/42 or U3/74
D677E
Reversing direct
87
Operation
Speed relation
Power relation
88
Low
speed
High
speed
Low
speed
High
speed
Delta
1
1
Double-Star
2
1,5 - 1,8
Star
1
0,3
Double-Star
2
1
D677E
Star-Delta Starters
Dimensions
Star-Delta Starters, AC operated, open type
K3Y15 + U3/32
K3Y26
K3Y15 + U12/16E G3
K3Y26
K3Y40 + U3/32
K3Y52 + U3/32
K3Y40 + U3/42
K3Y52 + U3/42
K3Y80 + U3/74
K3Y100 + U3/74
K3Y140 + U85
K3Y200
D677E
89
Star-Delta Starters
Dimensions
Star-Delta Starters, plastic enclosed, protected to IP65
K3Y26P
K3Y40P to K2Y100P
2 x 50,5/25,5 + 20,5
Type
K3Y40P
K3Y52P
272 320
272 320
6,5
6,5
32,5
32,5
32,5
32,5
60
60
60
60
K3Y80P
K3Y100P
272 420
272 420
6,5
6,5
40,5
50,5
40,5
40,5
70
70
70
70
K3Y26B
K3Y40B
K3Y52B
25,5
32,5
32,5
25,5
32,5
32,5
K3Y80B to K2Y200B
Type
K3Y80B
K3Y100B
340 340
340 340
8,7 65
8,7 65
K3Y140B
K3Y200B
560 340
560 340
8,7 65
8,7 65
Type
K3Y80B
K3Y100B
40,5
50,5
40,5
40,5
70
80
70
70
60
60
K3Y140B
K3Y200B
50,5
50,5
50,5
50,5
80
80
80
80
70
70
90
D677E
Reversing Contactors
Dimensions
Reversing Starters, AC operated, open type
K3WU10 + U3/32
K3WU18
K3WU10 + U12/16E G3
K3WU18
K3WU24 + U3/32
K3WU32
K3WU40
K3WU24 + U3/42
K3WU32
K3WU40
K3WU50 + U3/74
K3WU62
K3WU74
K3WU18B
K3WU24B
K3WU32B
300
300
300
300
300
300
150
150
150
250
250
250
250
250
250
30
30
30
30
30
30
25,5
32,5
32,5
41
41
41
K3WU50B
K3WU62B
300
300
300
300
150
150
250
250
250
250
40
40
40
40
32,5
32,5
59
59
D677E
91
K3PU18 + 2x U12/16
K3PU50 + 2x U3/74
K3PU62
K3PU18B
K3PU24B
K3PU32B
25,5
32,3
32,3
25,5
32,5
32,5
92
D677E
D.O
.L
.O.L
.L.. Starters
D677E
94
94
94
Enclosures
95
Accessories
95
Wiring Diagrams
96
Dimensions
98
93
Included Free
Contactor Space
f. Aux.
Cont.
HN..
Type
pcs.
Wired
Protec- Conduit
to
tion
Entries
accept Degree
Overload
Relay
Type
Type
Coil voltage 1)
230 220-240V 50Hz 230-264V 60Hz
400 380-415V 50Hz 400-440V 60Hz
Pack Weight
W
pcs.
kg/pc.
K3-10ND10 2
U12/16 K3 IP65
20,5mm
P1T10 . . .
0,6
7,5
K3-18ND10 2
U12/16 K3 IP65
20,5mm
P1T18 . . .
0,6
K3-22ND10 2
U12/16 K3 IP65
20,5mm
P1T22 . . .
0,6
11
K3-10ND10 2
U12/16 K3 IP65
20,5mm
P1W10 . . .
0,6
7,5
K3-18ND10 2
U12/16 K3 IP65
20,5mm
P1W18 . . .
0,6
K3-22ND10 2
U12/16 K3 IP65
20,5mm
P1W22 . . .
0,6
0,6
11
D.O.L. Starters with Selector Switch and Pneumatic Switch for moist rooms
7,5
K3-18ND10 2
U12/16 K3 IP65
20,5mm
P1W18P . . .
D.O.L. Starter with selector switch, plastic enclosed, rated AC3 at 400V 15,5A,
rated control voltage 230V 50Hz - Order Type: P1W18 230 + U12/16E 18 K3
Type
Pack Weight
pcs. kg/pc.
0,12 - 0,18
0,18 - 0,27
0,27 - 0,4
U12/16E 0,18 K3
U12/16E 0,27 K3
U12/16E 0,4 K3
1
1
1
0,10
0,10
0,10
0,4 - 0,6
0,6 - 0,9
0,8 - 1,2
U12/16E 0,6 K3
U12/16E 0,9 K3
U12/16E 1,2 K3
1
1
1
0,10
0,10
0,10
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U12/16E 1,8 K3
U12/16E 2,7 K3
U12/16E 4 K3
1
1
1
0,10
0,10
0,10
4
6
8
- 6
- 9
- 11
U12/16E 6 K3
U12/16E 9 K3
U12/16E 11 K3
1
1
1
0,10
0,10
0,10
10
13
17
- 14
- 18
- 23
U12/16E 14 K3
U12/16E 18 K3
U12/16E 23 K3
1
1
1
0,10
0,10
0,10
22
- 30
U12/16E 30 K3
0,13
D677E
manual reset
Type
K3-07.. to K3-22..
K3-24..1) to K3-40.. 1)
IP65
P1
2 x 20,5mm 2 x 20,5mm
Pack
pcs.
1
Weight
kg/pc.
0,35
Type
K3-10.. to K3-22..
+U12/16.. K3
IP65
P1R
2 x 20,5mm 2 x 20,5mm
Pack
pcs.
1
Weight
kg/pc.
0,35
Indicator Units
Specifications
Voltage Range
Type
Pack
pcs.
Weight
kg/pc.
K2-ING
K2-INR
10
10
0,02
0,02
Voltage Indicator
Indicator, clear (glow-disc. l.) 220 - 415V AC/DC
Indicator, red (LED)
24 - 120V AC/DC
Voltage Indicator
To be connected parallel to the contactor coil. In case of
applied voltage the indicator also lights at coil interruption.
K2-UN
K2-UNR
10
10
0,02
0,02
LG9743T
LG9743R
LG9743GR
10
10
10
0,005
0,005
0,005
Heating Element
Specifications
Voltage Range
Power Consumption
Type
K2-HR
K2-HR 230
Pack
pcs.
10
10
Weight
kg/pc.
0,02
0,02
Type
Cable Cross-sections to clamp mm
solid or
flexib. w. multistranded
flexible
core cable end
Neutral Terminal
2 x 0,75-4 2 x 0,75-2,5
Earth Terminal
2,5-16
1,5-10
Mounting instructions see page 100
Start Contact
1)
for contactor
K3-10 to K3-22
2 x 0,5-2,5
1,5-10
to be snapped on top of
the auxiliary contact
Pack
Weight
pcs.
kg/pc.
LG9744
LG9750
10
10
0,009
0,052
LG9319-K3
10
0,03
95
D.O.L. Starters
Wiring Diagrams Main Circuit
All fuses F0 shown in the main circuits are not included.
Terminal markings according to EN 50012
P1...
with overload relay U12/16.. K3
local control
or remote control
local control
or remote control
local control
or remote control
local control
or remote control
96
D677E
D.O.L. Starters
Wiring Diagrams Control Circuits
Typical circuit diagram (for separate coil supply, control circuit connected between L1 and N)
Terminal markings according to EN 50012
D.O.L. Starters with Start-Stop/Reset Push Buttons
P1T10, P1T18, P1T22
with overload relay U12/16.. K3
push button
ON/OFF
D677E
97
D.O.L. Starters
Dimensions
D.O.L. Starters with Start-Stop/Reset Push Buttons, Plastic Enclosed
P1T.., P1TP..
P1W.., P1W18P
98
D677E
Enclosures
Dimensions
Enclosures for Contactors
P1
P1R, P1P
D677E
99
D.O.L. Starters
Mounting and Wiring Instructions
Indicators and Lens Caps for D.O.L. Starters P1
K2-UN., K2-IN.
LG9743.
Wiring Examples
Coil Current Indicator
Voltage Indicator
Heating Element
K2-ING
K2-INR
K2-UN
K2-UNR
K2-HR
red
K2-HR 230
red
LG9750
LG9744
100
D677E
D677E
102
104
Accessories
105
Technical Data
106
Dimensions
111
101
Type
(A)
Pack Weight
pcs. kg/pc.
Wiring Diagram
U12/16E 0,18 K1
U12/16E 0,27 K1
U12/16E 0,4 K1
1
1
1
0,10
0,10
0,10
0,4 - 0,6
0,6 - 0,9
0,8 - 1,2
U12/16E 0,6 K1
U12/16E 0,9 K1
U12/16E 1,2 K1
1
1
1
0,10
0,10
0,10
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U12/16E 1,8 K1
U12/16E 2,7 K1
U12/16E 4 K1
1
1
1
0,10
0,10
0,10
4
6
8
- 6
- 9
- 11
7
- 10,5
10,5 - 15,5
14
- 19
U12/16E 6 K1
U12/16E 9 K1
U12/16E 11 K1
1
1
1
0,10
0,10
0,10
10
- 14
18
U12/16E 14 K1
0,10
- 24
manual reset
U12/16A 0,18 K1
U12/16A 0,27 K1
U12/16A 0,4 K1
1
1
1
0,10
0,10
0,10
0,4 - 0,6
0,6 - 0,9
0,8 - 1,2
U12/16A 0,6 K1
U12/16A 0,9 K1
U12/16A 1,2 K1
1
1
1
0,10
0,10
0,10
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U12/16A 1,8 K1
U12/16A 2,7 K1
U12/16A 4 K1
1
1
1
0,10
0,10
0,10
4
6
8
- 6
- 9
- 11
7
- 10,5
10,5 - 15,5
14
- 19
U12/16A 6 K1
U12/16A 9 K1
U12/16A 11 K1
1
1
1
0,10
0,10
0,10
10
- 14
18
U12/16A 14 K1
0,10
- 24
auto reset
or manual reset
With Quick Tripping Characteristic for EEx e motors and submersible pumps, f. contactors K1-..
102
0,4 - 0,6
0,6 - 0,9
0,8 - 1,2
U12/16EQ 0,6 K1
U12/16EQ 0,9 K1
U12/16EQ 1,2 K1
1
1
1
0,10
0,10
0,10
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U12/16EQ 1,8 K1
U12/16EQ 2,7 K1
U12/16EQ 4 K1
1
1
1
0,10
0,10
0,10
4
6
8
- 6
- 9
- 11
7
- 10,5
10,5 - 15,5
14
- 19
U12/16EQ 6 K1
U12/16EQ 9 K1
U12/16EQ 11 K1
1
1
1
0,10
0,10
0,10
10
- 14
18
U12/16EQ 14 K1
0,10
- 24
D677E
manual reset
Type
(A)
Pack Weight
pcs. kg/pc.
Wiring Diagram
U12/16E 0,18 K3
U12/16E 0,27 K3
U12/16E 0,4 K3
1
1
1
0,10
0,10
0,10
0,4 - 0,6
0,6 - 0,9
0,8 - 1,2
U12/16E 0,6 K3
U12/16E 0,9 K3
U12/16E 1,2 K3
1
1
1
0,10
0,10
0,10
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U12/16E 1,8 K3
U12/16E 2,7 K3
U12/16E 4 K3
1
1
1
0,10
0,10
0,10
4
6
8
- 6
- 9
- 11
7
- 10,5
10,5 - 15,5
14
- 19
U12/16E 6 K3
U12/16E 9 K3
U12/16E 11 K3
1
1
1
0,10
0,10
0,10
10
13
17
- 14
- 18
- 23
18
23
30
- 24
- 31
- 40
U12/16E 14 K3
U12/16E 18 K3
U12/16E 23 K3
1
1
1
0,10
0,10
0,10
22
- 30
38
- 52
U12/16E 30 K3
0,13
manual reset
U12/16EQ 0,6 K3
U12/16EQ 0,9 K3
U12/16EQ 1,2 K3
1
1
1
0,10
0,10
0,10
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U12/16EQ 1,8 K3
U12/16EQ 2,7 K3
U12/16EQ 4 K3
1
1
1
0,10
0,10
0,10
4
6
8
- 6
- 9
- 11
7
- 10,5
10,5 - 15,5
14
- 19
U12/16EQ 6 K3
U12/16EQ 9 K3
U12/16EQ 11 K3
1
1
1
0,10
0,10
0,10
10
- 14
18
U12/16EQ 14 K3
0,10
- 24
manual reset
U3/32 0,18
U3/32 0,27
U3/32 0,4
1
1
1
0,14
0,14
0,14
0,4 - 0,6
0,6 - 0,9
0,8 - 1,2
U3/32 0,6
U3/32 0,9
U3/32 1,2
1
1
1
0,14
0,14
0,14
1,2 - 1,8
1,8 - 2,7
2,7 - 4
U3/32 1,8
U3/32 2,7
U3/32 4
1
1
1
0,14
0,14
0,14
4
6
8
- 6
- 9
- 11
7
- 10,5
10,5 - 15,5
14
- 19
U3/32 6
U3/32 9
U3/32 11
1
1
1
0,14
0,14
0,14
10
13
17
- 14
- 18
- 24
18
23
30
- 24
- 31
- 41
U3/32 14
U3/32 18
U3/32 24
1
1
1
0,14
0,14
0,14
23
- 32
40
- 55
U3/32 32
0,14
manual and
auto reset
D677E
10
14
- 14
- 20
18
24
- 24
- 35
U3/42 14
U3/42 20
1
1
0,30
0,30
20
28
- 28
- 42
35
48
- 48
- 73
U3/42 28
U3/42 42
1
1
0,30
0,30
manual and
auto reset
103
Type
(A)
Pack Weight
pcs. kg/pc.
Wiring Diagram
- 28
- 42
- 52
35
48
70
- 48
- 73
- 90
U3/74 28
U3/74 42
U3/74 52
1
1
1
0,40
0,40
0,40
52
60
- 65
- 74
90
104
- 112
- 128
U3/74 65
U3/74 74
1
1
0,40
0,40
manual and
auto reset
Type
(A)
Pack Weight
pcs. kg/pc.
Wiring Diagram
- 90
-120
120
104
140
- 156
- 207
U85 90
U85 120
0,90
manual reset
208 - 312
U180 180
1,5
manual and
auto reset
250 - 374
374 - 554
U320 216
U320 320
1,8
416 - 623
623 - 935
U800 360
U800 540
1
1
4,1
4,1
540 - 800
935 - 1385
U800 800
4,1
With Slow Tripping Characteristic for heavy duty starting with long run up times
For separate mounting, suitable for all contactors
104
0,8 - 1,2
1,2 - 1,8
1,6 - 2,4
2,1
3,1
4,2
UAT21 1,2
UAT21 1,8
UAT21 2,4
1
1
1
1,0
1,0
1,0
2,4 - 3,7
3,7 - 5,7
5,3 - 8,2
4,2 - 6,4
6,4 - 9,9
9,2 - 14,2
UAT21 3,7
UAT21 5,7
UAT21 8,2
1
1
1
1,0
1,0
1,0
8
12
- 12
- 18
13,9 - 20,1
20,1 - 31,2
UAT21 12
UAT21 18
1
1
1,0
1,0
16
- 24
27,7 - 41,6
UAT22 24
1,1
24
32
48
- 37
- 49
- 72
41,6 - 64
55,4 - 85
83
- 125
UAT23 37
UAT23 49
UAT23 72
1
1
1
1,3
1,3
1,3
D677E
manual reset
Accessories
for overload relays
Type
for contactors
Pack Weight
set
kg/set
Busbar Sets
SU840/550
SU840/860
U800
U800
K3-450.. , K3-550..
K3-700.. , K3-860..
1,7
2,1
Pack Weight
pcs. kg/pc.
0,75 - 6
0,75 - 4
U12SM K3
0,035
U3/32SM
0,035
U3/42G
0,030
1
1
0,060
0,100
0,75 - 6
0,75 - 4
LG5830-4
LG5830-2
0,75 - 6
LG9339
0,009
6 - 25
LG7559
0,052
D677E
4 - 35
105
Setting Range
IA/I N
3
U3/32 ..
IA/I N
4
IA/IN
5
IA/I N
6
IA/IN
7,2
Setting Range
IA/IN
8
U12/16EQ ..
IA/I N
4
IA/I N
5
IA/I N
6
IA/IN
7,2
IA/IN
8
0,12
0,18
0,27
0,4
0,18
0,27
0,4
0,6
16,1
16,6
19,4
18,7
9,6
9,7
11,4
10,9
6,8
6,7
7,9
7,6
5,3
5,2
6,1
5,9
4,2
4,1
4,7
4,6
3,7
3,6
4,2
4,0
0,4
0,6
0,8
1,2
0,6
0,9
1,2
1,8
13,6
13,8
13,1
14,6
8,4
7,8
7,5
8,7
5,9
5,2
5,2
6,0
4,2
4,1
3,9
4,6
3,3
3,2
3,1
3,6
3,0
2,7
2,7
3,2
0,6
0,8
1,2
1,8
0,9
1,2
1,8
2,7
19,2
20,8
25,5
26,6
11,2
12,3
14,1
15,6
7,7
8,5
9,8
10,9
5,9
6,6
7,6
8,3
4,6
5,2
5,9
6,5
4,1
4,6
5,2
5,7
1,8
2,7
4
6
2,7
4
6
9
13,5
11,0
9,6
10,2
7,6
6,0
5,3
5,4
5,3
4,1
3,3
3,4
3,9
2,6
2,3
2,3
3,1
1,7
1,6
1,6
2,7
1,4
1,3
1,3
2,7
4
6
8
- 4
- 6
- 9
- 11
22,7
22,2
20,4
20,9
13,6
13,3
11,9
11,8
9,5
9,3
8,2
7,9
7,4
7,1
6,1
5,7
5,8
5,6
4,7
4,3
5,1
4,9
4,0
3,5
12,0
12,8
6,2
6,6
3,9
4,0
2,5
2,6
1,8
1,8
1,3
1,4
14
18
24
32
21,3
21,2
20,4
20,2
11,7
12,1
12,0
10,2
7,4
8,0
8,6
6,7
5,1
6,2
6,3
4,7
3,7
4,6
4,5
3,4
3,0
4,1
3,7
2,8
11,4
11,2
10,8
13,3
7,0
6,7
6,5
8,0
5,0
4,5
4,5
5,5
3,7
3,2
3,3
4,0
2,8
2,4
2,5
3,1
10
13
17
23
U3/42
10
14
20
28
14
20
28
42
21,8
22,4
21,8
25,2
s
28
42
52
65
21,8
25,2
18,3
17,8
10,8
13,3
9,2
8,7
s
- 90
- 120
19,5
18,0
s
360
480
620
800
23,3
23,0
20,5
21,0
14,1
13,8
12,4
12,5
10,0
9,6
9,0
9,0
U3/74
20
28
40
52
U85 ..
60
80
U840 ..
260
340
440
560
U12/16E(A) ..
6,5
8,0
5,6
5,2
4,5
5,5
3,9
3,4
3,3
4,0
2,8
2,5
2,5
3,1
2,2
1,9
13,5
11,0
11,0
10,0
10,0
9,0
9,5
8,5
8,5
8,0
7,6
7,6
7,0
7,0
6,1
6,1
5,5
5,6
5,4
5,4
5,0
5,2
0,12
0,18
0,27
0,4
0,18
0,27
0,4
0,6
18,5
16,7
19,4
18,7
10,4
9,8
12,1
11,2
7,2
6,5
8,2
8,0
5,5
5,0
5,9
6,0
4,3
4,1
4,9
4,9
3,6
3,5
4,2
4,1
0,6
0,8
1,2
1,8
0,9
1,2
1,8
2,7
19,7
22,9
22,2
23,0
11,6
13,6
13,2
13,7
8,1
10,0
9,2
9,3
6,1
7,3
7,6
7,6
4,9
6,0
5,8
5,7
4,2
5,2
5,3
5,1
2,7
4
6
8
- 4
- 6
- 9
- 11
24,0
24,7
22,0
17,4
14,4
13,8
13,4
9,2
9,9
9,9
8
5,9
7,8
7,3
5,7
4,1
5,9
5,6
4,1
2,9
5,1
4,8
3,5
2,3
14
18
23
30
26,4
14,7
16,2
16,8
12,9
7,7
8,4
8,5
7,6
4,8
5,0
5,0
5,2
3,2
3,6
3,6
3,5
2,3
2,4
2,3
2,8
1,7
1,8
1,9
10
13
17
22
106
8
10
- 11
- 14
All tripping times of overload relays U12/16EQ are shorter than the
minimum values of the tE time for motors of protection degree EEx e acc.
to EN 50019 and therefore are suitable for all motors of protection
degree EEx e. For these overload relays the selection on basis of
tripping curves is thereby not necessary.
When selecting a standard overload, refer to the tripping curve. Determine
the values of the starting current ratio IA/IN and the time tE which is marked
on the label of the motor. The overload must trip within the tE time, which
means that the tripping curve from cold condition must be (20% due to
tolerance) below the co-ordination point IA/IN and the time tE.
I N = Rated current of motor
I A = Starting current of motor
t E = tE-time of motor
Time tE /Tripping time
s
Typical tripping
curve for overload
relay U12/16E
Minimum values of
tE time (motor)
acc. to EN50019
Typical tripping
curve for overload
relay U12/16EQ
ratio IA/IN
Labels of tripping curves for each setting range, sized 148x105mm
(self-adhesive) are available on request.
Order No. D588, specify type and setting range.
Example of selection for thermal overload relay:
Technical data of a motor protection EEx e
PN= 1,5kW IN = 3,6A IA/IN = 5 tE time = 8s
1) U12/16E 4 (2,7 - 4A)
Tripping time at 5 x IN = 9,9s
9,9s + 20% tolerance = 11,9s > tE Motor = 8s
The device U12/16E 4 is not suitable
suitable.
2) U12/16EQ 4 (2,7 - 4A)
Tripping time at 5 x IN = 4,1s
4,1s + 20% tolerance = 4,9s < tE Motor = 8s
The device U12/16EQ 4 is therefore suitable
for motor protection
D677E
DOL
U3/32
(U12/16E)
SCCR
kA
0,5 2)
1,0 2)
2
0,5 2)
1,0 2)
2
25
25
25
15
15
15
5
5
5
0,6
0,9
1,2
2
4
4
2
4
4
25
25
25
15
15
15
5
5
5
1,8
2,7
4
6
10
16
6
10
10
25
25
25
2
4
4
15
15
15
5
5
5
- 6
- 9
- 11
7 - 10,5
10,5 - 15,5
14 - 19
20
35
35
16
25
25
25
35
35
6
10
16
15
25
30
5
5
5
- 14
- 18
(23)24
-(23)24
18
23
30
- 24
- 31
-(40)41
50
50
63
35
35
50
63
63
63
16
20
25
40
50
60
5
5
5
-(30)32
(30)32 (38)40
-(52)55
80
63
80
35
70
10
14
- 14
- 20
18
24
- 24
- 35
50
63
35
50
80
80
16
25
40
60
5
5
20
28
- 28
- 42
35
48
- 48
- 73
80
100
63
80
80
150
35
50
80
110
5
5
20
28
- 28
- 42
35
48
- 48
- 73
100
125
80
100
150
150
35
50
80
110
5
5
40
52
60
- 52
- 65
- 74
70
90
104
- 90
- 112
- 128
160
160
160
100
125
125
150
150
150
63
80
80
200
250
250
5
10
10
60
80
- 90
-120
120
104
140
- 156
- 207
300
-
10
10
(22)23
U85
Fuse UL
0,18
0,27
0,4
10
13
17
U3/74
4
6
8
U3/42
Setting Range
U180, U320
U800
all ranges
all ranges
Tripping time
min. s
Tripping time
min. s
F. L. C. multiplication factor
1) Coordination-type according to IEC 947-4-1:
"2": Light contact welding accepted. Thermal overload relay must not be damaged.
"1": Welding of contactor and damage of the thermal overload relay allowed.
2) Miniature fuse
D677E
K =Imax /Ie
107
F. L. C. multiplication factor
F. L. C. multiplication factor
F. L. C. multiplication factor
K =Imax / Ie
Position of Terminals
U3/32
108
U12/16A
U3/42, U3/74
D677E
Setting Range
Setting Range
0,6
0,9
1,2
2
4
4
2
4
4
25
25
25
0,18
0,27
0,4
none
none
none
none
none
none
on request
on request
on request
1,8
2,7
4
6
10
16
6
10
10
25
25
25
0,6
0,9
1,2
none
none
none
none
none
10
on request
on request
on request
1,8
2,7
4
none
20
35
16
20
35
on request
on request
on request
4
6
8
- 6
- 9
- 11
20
35
35
16
25
25
25
35
35
10
- 14
50
35
63
Tripping time
min. s
Detailed tripping times for each range see table page 106
Tripping time
min. s
F. L. C. multiplication factor
Tripping time
min. s
F. L. C. multiplication factor
F. L. C. multiplication factor
1) Coordination-type according to IEC 947-4-1:
"2": Light contact welding accepted. Thermal overload relay must not be damaged.
"1": Welding of contactor and damage of the thermal overload relay allowed.
D677E
109
U3/32
U12/16 6)
V~
Permissible ambient temperature
operation
open C
storage
C
690
690
10A
690
750
10A
10A
auxiliary connector
solid mm
flexible mm
flexible with multicore cable end mm
Cables per clamp
number
Type
U12/16A
V~
V~
690
440
690
-
690
440
A
A
A
A
3
2
1
0,5
4
2,5
1,5
0,6
24V A
110V A
220V A
1
0,15
0,1
24V
230V
400V
690V
Type
Setting range
Power loss per current path (max.)
minimum setting value
maximum setting value
W
W
1000
690
-25 to +55
-40 to +70
10A
20
10A
3)
7)
10A
-
30
7)
690
30
30
1-2,52)
1-2,5 2)
1-2,5 2)
2
U12/16E U12/16EQ
U12/16EM
690
-25 to +60
-50 to +70
10
0,75-2,5 2)
0,5-2,5 2)
0,5-1,5
2
U3/32
Auxiliary contacts
Rated insulation voltage Ui 1)
same potential
different potential
690 1000
-25 to +60
-50 to +70
Cable cross-section
main connector
solid or stranded mm 0,75-6 0,75-6+0,75-2,5 2) 0,75-10 4-35 2)
flexible mm
1-4 0,75-4+0,5-2,5 2 ) 0,75-6 6-25 2)
flexible with multicore cable end mm 0,75-4 0,5-2,5+0,5-1,5 0,75-6 4-25
Cables per clamp
number
2
1+1
2
1
U800
1)
0,75-2,5 2)
0,5-2,5 2)
0,5-1,5
2
U3/42
U3/74
U85
U180
U320
U800
UAT21
UAT22
UAT23
690
440
690
250
690
440
690
440
500
500
690
440
5
3
2
0,6
5
3
2
0,6
4
2,5
1,5
0,6
5
3
2
0,6
3
2
1
0,5
4 5)
2,5
1,5
0,6
5
3
2
0,6
1,2
0,15
0,1
1,2
0,15
0,1
1,2
0,15
0,1
1,2
0,15
0,1
1,2
0,15
0,1
1,2
0,15
0,1
1,2
0,15
0,1
1,2
0,15
0,1
U3/32
all
U12/16
to 23A
U12/16E
22 - 30A
U3/42
to 28A
U3/42
28 - 42A
U3/74
to 52A
U3/74
52 - 65A
U85
all
1,1
2,3
1,1
2,3
1,7
3,7
1,3
2,6
1,3
3,3
2,0
3,7
2,9
4,5
1,1
2,5
U3/32
U12/16A
U12/16E
U12/16EQ
U3/42
U3/74
U85
V~
A
600
32
600
23
600
23
600
23
600
42
600
74
600
85
Auxiliary contacts
Rated voltage
same potential
different potential
V AC
V~
600
150
600
-
600
150
600
150
600
150
600
150
600
150
Switching capacity AC
of aux. contacts
VA
A
500
2
500
3
500
4
500
4
600
4
600
4
600
4
Temperature Compensation
In case of higher ambient temperature use the following formula:
(Ambient temperature - 20) x 0,125 = correction factor in %
of the
full load motor current
1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV (at 440V), 6kV (at 690V).
Data for other conditions on request.
2) Maximum cable cross-section with prepared conductor
3) Without terminals, suitable for bushing one connector 70mm (stranded) per phase
4) Switching capacity of the start contact: AC15 300VA, max. 1,5A, DC13 (max. 220V) 30W, max. 1,5A
5) Switching capacity of the make contact: AC15 400VA, max. 1,7A, DC13 (max. 220V) 10W, max. 1A
6) U12/16E 30: Cable cross-section for main connector like type U3/42, one connector only
7) Busbar sets see accessories page 103
110
D677E
KG3-10 + U3/32
KG3-14
KG3-18
KG3-22
K3-24 + U3/32
K3-32
K3-40
KG3-24 + U3/32
KG3-32
KG3-40
K3-24 + U3/42
K3-32
K3-40
KG3-24 + U3/42
KG3-32
KG3-40
U3/32SM
U3/42G +LG5830-.
D677E
111
K3-10 + U12/16..K3
K3-14
K3-18
K3-22
K3-10N + U12/16..K3
K3-14N
K3-18N
K3-22N
KG3-10 + U12/16..K3
KG3-14
KG3-18
KG3-22
U12SM K3
U12/16..K3 + U12SM K3 for snap-on 35mm DIN-rail according to
DIN EN50022 and screw mounting (single mounting)
K3-50 + U3/74
K3-62
K3-74
112
D677E
K3-151A00 + U180
K3-176A00
Bohrplan
K3-210A00 + U320
K3-260A00
K3-316A00
Bohrplan
D677E
113
U800 with
K3-450
K3-550
40 185 225
40 196 225
12,5
12,5
9
9
K3-700
K3-860
50 257 291
50 280 291
14,5
14,5
11
11
UAT21
UAT22
UAT23
Type
Setting Range
UAT23 37
UAT23 49
UAT23 72
23-37A
32-49A
48-72A
114
105,5
94
94
97,5
86
86
D677E
Modular Contactors
D677E
Modular Contactors
116
117
117
118
Switching Of Lamps
118
Technical Data
120
Dimensions
122
115
Modular Contactors
Rated Heating Power
Current AC1 at
AC1
400V
A
Type
1-phase 3-phase
230V
400V
kW
kW
24
230
24VM
230VM
coil voltage
24V 50/60Hz
220-240V 50Hz, 230-264V 60Hz
24V 50/60Hz, 24V DC
220-240V 50/60Hz, 220V DC
Pack
Weight
pcs.
kg/pc.
Wiring Diagram
4,6
4,6
R20-10 24
R20-10 230
12
12
0,12
0,12
4,6
4,6
R20-20 24
R20-20 230
12
12
0,12
0,12
20
20
4,6
4,6
R20-11 24
R20-11 230
12
12
0,12
0,12
20
20
4,6
4,6
R20-02 24
R20-02 230
12
12
0,12
0,12
25
25
5,5
5,5
R25-20 24
R25-20 230
12
12
0,14
0,14
25
25
5,5
5,5
R25-11 24
R25-11 230
12
12
0,14
0,14
25
25
5,5
5,5
R25-02 24
R25-02 230
12
12
0,14
0,14
5,7
5,7
17
17
R25-40 24
R25-40 230
6
6
0,21
0,21
25
25
5,7
5,7
17
17
R25-31 24
R25-31 230
6
6
0,21
0,21
25
25
5,7
5,7
17
17
R25-13 24
R25-13 230
6
6
0,21
0,21
25
25
5,7
5,7
R25-22 24
R25-22 230
6
6
0,21
0,21
25
25
5,7
5,7
17
17
R25-04 24
R25-04 230
6
6
0,21
0,21
5,7
5,7
17
17
R25-40 24VM
R25-40 230VM
6
6
0,22
0,22
25
25
5,7
5,7
17
17
R25-31 24VM
R25-31 230VM
6
6
0,22
0,22
25
25
5,7
5,7
17
17
R25-13 24VM
R25-13 230VM
6
6
0,22
0,22
25
25
5,7
5,7
R25-22 24VM
R25-22 230VM
6
6
0,22
0,22
25
25
5,7
5,7
17
17
R25-04 24VM
R25-04 230VM
6
6
0,22
0,22
1) Sealable with Sealing Cover P721, available aux. contact block RH11(see page 117)
2) Sealable with Sealing Cover P721, available aux. contact block RH11-1(see page 117)
116
D677E
Modular Contactors
R a t e d Heating
Current AC1 at
AC1
1-phase
400V 230V
A
kW
Type
Power
3-phase
400V
kW
coil voltage
24V 50/60Hz
220-240V 50Hz, 230-264V 60Hz
Pack
Weight
pcs.
kg/pc.
Wiring Diagram
24
230
9
9
R40-20 24
R40-20 230
6
6
0,23
0,23
63
63
14,3
14,3
R63-20 24
R63-20 230
6
6
0,23
0,23
9
9
27,5
27,5
R40-40 24
R40-40 230
4
4
0,35
0,35
40
40
9
9
27,5
27,5
R40-31 24
R40-31 230
4
4
0,35
0,35
40
40
9
9
R40-22 24
R40-22 230
4
4
0,35
0,35
40
40
9
9
27,5
27,5
R40-04 24
R40-04 230
4
4
0,35
0,35
63
63
14,3
14,3
43
43
R63-40 24
R63-40 230
4
4
0,36
0,36
63
63
14,3
14,3
43
43
R63-31 24
R63-31 230
4
4
0,36
0,36
63
63
14,3
14,3
R63-22 24
R63-22 230
4
4
0,36
0,36
63
63
14,3
14,3
43
43
R63-04 24
R63-04 230
4
4
0,36
0,36
Auxiliary Contact Block module (8,8mm) for contactor R25 (4p.), R40, R63 (max. 1pc.)
Rated
AC15
230V
A
current
AC15 AC1
400V 690V
A
A
Type
for contactor
2),
10
R25
10
R25-..VM
VM
R40, R63
Accessories
Pack
pcs.
kg/pc.
RH11
0,026
RH11-1
0,026
Pack
pcs.
Weight
kg/pc.
Type
RC-unit
2x for R20.. to R63..
for 12V to 250V AC
220nF / 100 Ohm
not for R25-..VM
RC-R 230
0,05
P730
10
0,012
P721
P690
10
10
0,002
0,003
Weight
Wiring Diagram
40C
40 - 60C
1) Sealable with Sealing Cover P690, available aux. contact block RH11
2) AC-operated R25-.., 4-pole
D677E
117
Pack
pcs.
Weight
kg/pc.
R25-TN 230
0,22
Wiring Diagram
2 Switch positions:
Day (Reloading, contact 11-14 ... closed, remains in position Night, until the next occurs)
Night (Basis operation) contact 11-12 ... closed
R25-TN20 230
0,13
4 Switch position:
Day (Reloading, contact 1-2 ... closed, remains in position Night, until the next occurs)
Night (automatic operation, contact 1-2 ... only at night closed)
On (Permanently On)
Off (permanently Off)
RH25-20
0,13
Modular Contactors
Switching of lamps
Lamp Type
Incandescent lamps
Fluorescent lamps
uncompensated or
serial compensated
Fluorescent lamps
dual-connection
Fluorescent lamps
parallel compensated
118
Power
W
Current
A
Capacitors
F
60
100
200
0,27
0,45
0,91
22
13
10
50
30
15
92
55
27
129
77
38
300
500
1000
1,36
2,27
4,5
4
3
1
10
6
3
19
11
6
26
16
8
11
18
24
0,16
0,37
0,35
1,3
2,7
2,5
60
25
25
75
30
30
210
90
90
310
140
140
36
58
65
85
0,43
0,67
0,67
0,8
3,4
5,3
5,3
5,3
20
14
13
11
25
17
16
14
70
45
40
35
140
70
65
60
11
18
24
0,07
0,11
0,14
2 x 100
2 x 50
2 x 40
2 x 110
2 x 55
2 x 44
2 x 220
2 x 130
2 x 110
2 x 250
2 x 200
2 x 160
36
58
65
85
0,22
0,35
0,35
0,47
2 x 30
2 x 20
2 x 15
2 x 10
2 x 33
2 x 22
2 x 16
2 x 11
2 x 70
2 x 45
2 x 40
2 x 30
2 x 100
2 x 70
2 x 60
2 x 40
11
18
24
0,09
0,13
0,16
2,0
2
3
30
20
15
43
32
32
67
50
50
107
80
80
36
58
65
85
0,27
0,45
0,5
0,6
4
7
7
8
10
6
5
4
32
18
18
16
50
36
36
33
80
46
46
44
D677E
Modular Contactors
Switching of lamps
Lamp Type
Power
W
Fluorescent lamps
with electronic fluorescent
lamp ballast
2
2
2
2
2
Mercury-vapour lamps
(high-pressure lamps),
compensated
e. g. HQL, HPL
0,09
0,16
0,25
0,4
40
20
15
7
40
20
15
10
100
52
30
20
150
75
55
30
18
28
36
58
80
0,17
0,25
0,32
0,49
0,7
20
15
10
7
4
20
15
10
7
4
50
37
25
15
8
60
45
30
20
10
20
50
75
0,09
0,22
0,33
40
20
13
52
24
16
110
50
35
174
80
54
100
150
200
300
0,43
0,65
0,87
1,30
10
7
5
3
12
9
5
4
27
19
14
9
43
29
23
14
50
80
125
0,61
0,8
1,15
16
12
8
21
16
11
38
29
20
55
40
28
250
400
700
1000
2,15
3,25
5,4
7,5
4
3
1
1
6
4
2
1
11
7
4
3
15
10
6
4
50
80
125
0,28
0,41
0,65
7
8
10
7
5
3
18
16
13
36
31
25
50
44
35
250
400
700
1000
1,22
1,95
3,45
4,8
18
25
45
60
2
1
1
-
7
5
3
2
14
10
6
4
19
14
8
6
35
70
150
0,53
1
1,8
22
12
6
24
14
8
57
30
17
65
35
18
x
x
x
x
x
250
400
1000
2000
3
3,5
9,5
16,5
4
3
1
-
5
4
1
-
10
8
3
2
12
10
4
2
2000
3500
10,5
18
2
1
2
1
6
12
20
8
4
2
21
11
7
42
21
13
58
29
18
35
70
150
Capacitors
F
18
36
58
80
Transformers
for metal halid
low voltage lamps
Mercury-vapour lamps
(high-pressure lamps),
uncompensated
e. g. HQL, HPL
Current
A
0,25
0,45
0,75
250
400
1000
2000
1,5
2,1
5,8
11,5
33
35
95
148
1
1
-
4
4
1
-
9
9
3
2
11
10
4
2
2000
3500
6,6
11,6
58
100
3
2
4
3
integrated
integriert
integrated
integrated
integrated
9
6
5
4
9
6
5
4
18
11
10
8
20
18
13
12
10
20
28
35
70
150
0,1
0,15
0,2
0,36
0,7
35
55
90
1,5
1,5
2,4
7
7
4
9
9
6
22
22
13
30
30
19
135
150
180
200
3,3
3,3
3,3
3,3
3
3
3
3
4
4
4
4
10
10
10
10
14
14
14
14
Sodium-vapour lamps
(low pressure lamps),
uncompensated
D677E
119
Modular Contactors
Switching of lamps
Lamp Type
Power
W
Sodium-vapour lamps
(low pressure lamps),
compensated
Sodium-vapour lamps
(high pressure lamps),
uncompensated
Sodium-vapour lamps
(high pressure lamps),
compensated
Sodium-vapour lamps
(high pressure lamps)
with serial electronic
(e. g.: PCI)
50-125 x Inlamp for 0,6ms
Current
A
Capacitors
F
35
55
90
0,31
0,42
0,63
20
20
30
3
2
1
6
6
4
15
15
10
18
18
12
135
150
180
200
0,94
1
1,16
1,32
45
40
40
25
1
1
1
-
3
3
3
-
7
8
8
10
8
9
9
12
150
250
330
1,8
3
3,7
5
4
3
8
5
4
17
10
8
22
13
10
400
1000
4,7
10,3
2
1
3
1
6
3
8
4
150
250
330
0,83
1,5
2
20
33
40
2
1
1
7
4
3
20
12
10
25
15
13
400
1000
2,4
6,3
48
106
1
-
2
1
8
4
12
6
20
35
70
150
0,1
0,2
0,36
0,7
integrated
integrated
integrated
integrated
9
6
5
4
9
6
5
4
18
11
10
8
20
13
12
10
R25
R40
R63
4-pole
R25
R40
R63
RH11
440 2)
440
440 2)
440
440 2)
440
440 2)
440
440 2)
440
440 2)
440
440 2)
440
440 2)
440
300
1
300
1
600
1
600
1
300
1
600
1
600
1
600
1
20
25
40
63
25
40
63
0,1
24/100
72
3
0,1
24/100
72
3
0,1
24/100
216
7
0,1
24/100
240
2
0,1
24/100
72
3
0,1
24/100
216
7
0,1
24/100
240
0,5
17/5
-
27
30
Type
Main Contacts 5) 6) 7)
Rated insulation voltage U i
Rated operation voltage Ue
Contact life
Minimum Switch Voltage
Short time current
10s-current
Power loss per pole at Ie/AC1
W
V~
V~
A
106
Sx
V/mA
A
2
220V
230-240V
380-415V
kW
kW
kW
2,2
2,5
4
7,5
8
12,5
8
8,5
15
230V
kW
1,1
1,3
2,6
S x 106
0,15
0,15
0,15
0,15
0,15
0,15
0,15
7-9
2,2 - 4,2
0,8 - 1,6
-
7-9
2,2 - 4,2
0,8 - 1,6
-
5-7
5-7
33 - 45
6-8
2,6
-
33 - 45
6-8
2,6
-
0,85 - 1,1
0,85 - 1,1
0,85 - 1,1
0,85 - 1,1
0,85 - 1,1
2-pole motors
Contact life
VA
VA
W
W
20
4
1,5
3
25
6
2,5
4
0,85 - 1,1
1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
2) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV.
3) Maximum cable cross-section with prepared conductor
5) Rated frequency 50/60Hz
6) Max. occ. switching overvoltage <4kV
7) Duty cycle: 100%
120
D677E
Modular Contactors
Data according to IEC60 947-4-1, IEC 60947-5-1, VDE 0660-5-1
Type
R20
R25-..VM
R40
R63
RH11
35
3
3
35
3
3
35
3
10
35
3
10
63
3
10
80
3
10
7 - 16
6 - 12
10 - 15
7 - 16
6 - 12
10 - 15
9 - 15
4-8
10 - 15
17 - 24
17 - 23
10 - 15
11 - 15
6 - 13
10 - 15
11 - 15
6 - 13
10 - 15
Cable cross-sections
Main connector
solid or stranded
flexible
flexible with multicore cable end
Clamps per pole
mm
mm
mm
1,5 - 10
1,5 - 6
1,5 - 6
1
1,5 - 10
1,5 - 6
1,5 - 6
1
1,5 - 10
1,5 - 6
1,5 - 6
1
1,5 - 10
1,5 - 6
1,5 - 6
1
2,5 - 25
2,5 - 16
2,5 - 16
1
2,5 - 25
2,5 - 16
2,5 - 16
1
0,5 - 2,5 3)
0,5 - 2,5 3)
0,5 - 1,5
2
mm
mm
mm
0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1
0,75 - 2,5
0,5 - 2,5
0,5 - 2,5
1
0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1
0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1
0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1
0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1
V AC
A
A
440 2)
10
6
220-240V
380-415V
440V
A
A
A
24-60V
110V
220V
A
A
A
Magnetic coil
solid or stranded
flexible
flexible with multicore cable end
Clamps per pole
Auxiliary Contacts 5) 6) 7)
Rated insulation voltage Ui 1)
Thermal rated current Ith
Ambient temperature
Utilization category AC15
Rated operational
current Ie
Utilization category DC13
Rated operational
current Ie
per pole
40C
60C
3
2
1,6
2
0,4
0,1
10
Type
R20
20
25
25
1
2
3
3
110-120V
200-208V
220-240V
265-277V
hp
hp
hp
hp
110-120V
200-208V
220-240V
265-277V
hp
hp
hp
hp
1
1
1
Fuses
Suitable for use on a capability of delivering not more than
rms
A
A
V
1
1
2
1
1
2
R40
R63
RH11
40
63
10
2
5
7
7
1
2
3
3
3
7
10
10
1
3
5
5
40
5000
300
40
5000
300
40
5000
300
80
5000
300
80
5000
300
300
V~
300
300
300
300
300
300
AC
C300
2) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV.
3) Maximum cable cross-section with prepared conductor
4) AC7b motor 2-pole 230V 1,1kW
5) Rated frequency 50/60Hz
6) Max. occ. switching overvoltage <4kV
7) Duty cycle: 100%
D677E
121
Modular Contactors
Dimensions
R20-.., R25-.. (2-pole)
RC-R 230, RH25-20
R25-TN
R40-.. (2-pole)
R63-.. (2-pole)
+32
France
Teconex
Material Electrique
Rue de Magnee 108
B - 4610 Beyne-Heusay
Tel: 04 / 355 88 26
Fax: 04 / 358 21 97
[email protected]
www.teconex.eu
Teconex
Material Electrique
Rue de Magnee 108
B - 4610 Beyne-Heusay
Tel: 04 / 355 88 26
Fax: 04 / 358 21 97
[email protected]
www.teconex.eu
Bulgaria
+359
Germany
+49
Schrabul Ltd
Yordan Yovkov Str. 8
BG - 1408 Sofia
Tel: 02 / 958 76 54
Fax: 02 / 958 59 95
[email protected]
Cyprus
+357
Rudolf Kiesewetter
Tel: 0341 / 550 16 06
Messtechnik GmbH
Fax: 0341 / 550 16 09
Prager Strasse 34
[email protected]
D - 04317 Leipzig
www.kiesewetter-mt.de
Representation for Postleitzahlgebiet 0
M. Hadjioannou Ltd.
Electrotechnical & Lighting Specialists
Aegeos 8c, Pallouriotissa
CY - Nicosia
Denmark
+45
Finland
+358
UTU Powel Oy
Palopellonkatu 7
PL 33
FIN - 04251 Kerava
Tel: 09 / 274 64 11
Fax: 09 / 274 64 141
[email protected]
www.urhotuominen.fi
122
+32
TVB GmbH
Tel: 040 / 608 750 22
Bro fr Elektroanlagen u. Gerte Fax: 040 / 608 750 23
Hartje Rterweg 88
[email protected]
D - 22399 Hamburg
www.tvb-hamburg.de
Representation for Postleitzahlgebiete 1, 2 and 3
Wagner GmbH
Tel: 02058 / 782 800-0
Werksvertretungen d. Elektroind.
Fax: 02104 / 752 800-49
Robert Bosch Strae 35
[email protected]
D - 42489 Wlfrath
www.wagnergmbh.de
Representation for Postleitzahlgebiete 4 and 5
Wilhelm Becker
Tel: 06175 / 798 194
Elektro-Handelsvertretung
Fax: 06175 / 798 195
Zum Kpperner Tal 17
[email protected]
D - 61381 Friedrichsdorf-Burgholzhausen www.becker-ehv.de
Representation for Postleitzahlgebiete 6 and 7
SBV - Gawehn GmbH
Tel: 09101 / 9099-0
Industrievertretungen
Fax: 09101 / 9099-30
Zollnerstrae 2
[email protected]
D - 90579 Langenzenn
Representation for Postleitzahlgebiete 8 and 9
D677E
+44
Romania
+40
Imsat International SA
Str. Episcop Radu nr. 15A
sect. 2, cod 72159
RO - 76548 Bukarest
Tel: 01 / 210 25 81
Fax: 01 / 210 30 35
[email protected]
www.imsatint.ro
Russia
+7
Hungaria
+36
Dial-Comp GmbH
Keszkeno u. 46/b.
H - 1131 Budapest
Spain
+34
Cydesa
Construcciones y Distribuciones,
Elctricas, S.A.
C.Poligono Industriel Sant
Antoni Parcela 2 Nave A
E - 08620 Sant Vicenc Dels Horts
Barcelona
Tel: 93 / 656 59 50
Fax: 93 / 656 65 59
[email protected]
www.cydesa.com
Sweden
+46
Wallin & Co AB
Gtlundagatan 10
Box 420
S - 12404 Bandhagen
Switzerland
+41
Benedict Swiss AG
Grindelstrae 19
CH - 8303 Bassersdorf
Tel: 44 / 213 66 00
Fax: 44 / 213 66 09
[email protected]
www.benedict-swiss.ch
+381
Elektro-K
oil d.o.o.
Elektro-Koil
Osjecka 4
SRJ-11000 Belgrad
Tel: 11 / 35 42 631
Fax: 11 / 35 71 911
www.elektrokoil.co.yu
Turkey
+90
Greece
+30
Italy
+39
SIF Trading
Via Per Curnasco 64
I - 24127 Bergamo
Netherlands
+31
Hirsch-Driebergen B.V
B.V..
Postbus 143
NL - 3970 AC Driebergen
Norway
+47
Gylling T
eknikk AS
Teknikk
P. O. Box 103
Rudssletta 71
N - 1351 Rud
Tel: 67 / 15 14 00
Fax: 67 / 15 14 01
[email protected]
www.gylling.no
Poland
+48
Tel: 61 / 848 88 71
Fax: 61 / 848 82 76
[email protected]
www.astat,com.pl
Tel: 22 / 723 06 62
Fax: 22 / 723 06 06
[email protected]
www.automatech.pl
Portugal
+351
Jayme da Costa
Mecanica e Electricidade, S.A.
Rua de Murraceses, 216
P - 4416 - 901 Pedroso
Tel: 22 / 74 70 250
Fax: 22 / 76 40 548
[email protected]
www.jaymedacosta.pt
D677E
[email protected]
www.dialelectrolux.ru
123
+61
New Zealand
+64
Tel: 02 / 9986 17 11
Fax: 02 / 9986 17 66
[email protected]
www.bridex-ets.com.au
Bolivia
+591
+65
Tel: 04 / 425 10 62
Fax: 04 / 425 10 61
[email protected]
www.agsa.com
Canada
+1
South Africa
+27
Deebar
Mining & Ind. Supplies
P.O. Box 40325
RSA - 2022 Cleveland
Egypt
+20
Economic Co.
Electrical Commerce & Import
44, Naguib El-Rihani St.
ET - Kairo
Tel: 02 / 592 91 80
Fax: 02 / 590 78 82
[email protected]
Electric Assemblies
Unit 2A Simplex Ind. Park
Engine Road,
RSA - 7441 Cape Town
Syria
+963
Hong Kong
+852
T. S. Boyadjian
Electrical Equipments
Halbouni Street no. 9
P.O. Box 2822
SYR - Damaskus
Taiwan
+886
Iran
+98
Tel: 21/77631517
Tel: 21-77509555
[email protected]
www.naderpardaz.ir
U.A.E.
+971
Israel
+972
Tel: 04 / 33 62 880
Fax: 04 / 33 62 890
[email protected]
www.doepke.de
Tel: 03 / 687 92 66
Fax: 03 / 688 26 91
[email protected]
www.gino-ind.com
USA
+1
Kenya
+254
Zimbabwe
+263
Mexico
+52
Tel: 9 / 715 24
Fax: 9 / 776 18
[email protected]
124
[email protected]
www.bnj-usa.com
D677E
Alphabetical Index
Description
Type
Page
LG..
LG..
LG..
LG..
HK..
HKM..
HA..
HB11
HN..
HK..
RH11
37
97
77
105
8
10, 14
22, 34
34
22, 34
34
117
SU840/...
99
K3-18K..
K3-24K..
K3-32K..
K3-50K..
K3-62K..
K3-74K..
K3-90K..
K3-115K..
K3-07..
KG3-07A..
K3-10A..
K3-14A..
K3-18A..
K3-22A..
K3-24A..
K3-32A..
K3-40A..
K3-50A..
K3-62A..
K3-74A..
K3-90A..
K3-115A..
K3-151A..
K3-176A..
K3-210A..
K3-260A..
K3-316A..
K3-450A..
K3-550A..
K3-700A..
K3-860A..
K3-1000A..
K3-1200A..
KG3-10A..
KG3-14A..
KG3-18A..
KG3-22A..
KG3-24A00
KG3-32A00
KG3-40A00
K3-10A00-40
K3-14A00-40
K3-18A00-40
K3-22A00-40
K2-23A00-40
K2-30A00-40
K2-37A00-40
K2-45A00-40
K2-60A00-40
K3-116A00-40
K3-151A00-40
K3-176A00-40
K3-210A00-40
K3-260A00-40
K3-316A00-40
33
33
33
33
33
33
33
33
12
39
20, 21
21
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
31
31
31
31
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
P1T, K2U..PT
P1W, K2U..PW
P1W18P
96
96
96
Contactors 4-pole
Description
Type
K2-TA..
K2-TE..
Y9..
P1
P1R
35
35
77
97
97
K3-../FG...
NP..
K2-F
40
37
36
K2-HR
97
K2-IN.
LG9743..
K2-UN.
K2-IM
Latch
K2-L..
LG.., P...
LG..
K1-07D..
K1-09..
K1-12D..
K1-09F..
K1-09L..
K1W09D..
K1W12D..
K1W09L..
R20..
R25..
R40..
R63..
HTN..
LG7735
K2-..SM, P...
Parallel Connectors
Pneumatic Timer
Pole Changing Starters Open Type
Pole Changing Starters Steel Sheet Enclosed
LG..
K2-TP..
K3PU..
K3PU..B
38
35
80
80
K2-RF.
K1W-VB
K3W-VB..
K3WU..
KW3-..
K2WU..B
36
14
78
78
80
78
U12SM
U3/32SM
U3/42G
EK../..
K../4..
K3Y-VB..
K3Y..
K3Y..P
K3Y..B
RC-K1
RC..
RC-R..
K2-E...
VG-K2/..
105
105
105
42
40, 41
77
74
76
76
10
38
117
38
38
D677E
K2-SK
K2-DK
LG..
U12/16A .. K1
U12/16E .. K1
U12/16EQ .. K1
U12/16E .. K3
U12/16EQ .. K3
U3/32 ..
U3/42 ..
U3/74 ..
U85 ..
U180 ..
U320 ..
U800 ..
UAT..
Page
36, 97
97
36, 97
36
36
38
37
8
10
10
12
12
14
14
14
116
116
116
116
34
77
36, 38
34
34
37
102
102
102
103
103
74,103
74,103
75,104
75,104
75,104
104
104
104
125