Kontakt or I

Download as pdf or txt
Download as pdf or txt
You are on page 1of 126

Contactors

Motor-Starters

D677E121

Index

Page
General

Approvals
Technical Information
Mounting Information

2
3
5
6

Mini Contactors
Mini Contactors
Interface Contactors
Mini Reversing Contactors
Technical Information
Dimensions

7
8
8
14
15
20

Contactor Relays
Contactor Relays
Technical Information
Dimensions

21
22
24
26

Contactors

Contactors Overview
Contactors, 3-pole
Contactors, 4-pole
Capacitor Switching Contactors
Accessories
Technical Information
Dimensions

27
28
30
32
33
34
43
64

Star-Delta Starters
Reversing Contactors
Pole Changing Starters
Technical Information
Dimensions

73
74
78
80
82
89

Starters

D.O.L. Starters
D.O.L. Starters
Enclosures
Accessories
Technical Information
Dimensions

93
94
95
95
96
98

Overload Relays
Thermal Overload Relays
Accessories
Technical Information
Dimensions

101
102
103
106
111

Modular Contactors
Contactors
Accessories
Technical Information
Dimensions

115
116
117
118
122

Representatives and Suppliers


Alphabetical Index

122
125

Detailed Table of Contents may be found at beginning of each section


Technical data, dimension sketches, illustrations and weights given in our list and printed matter, are subject to change without notice.
D677E

02 2012

General
Test Authorities, Registration Mark, Approvals

CE-Marking

Low voltage switchgear from Benedict GmbH is built and tested


to national and international specifications. All devices suit all
important specifications without any test obligation, like VDE, BS
and also relative to IEC Recommendations and to European Standards
like IEC 947 and EN 60947.
It is for this reason of our Low voltage switchgear is used all over the
world. In order to provide special versions, limitations to the max.
voltages, currents and power ratings or special markings are
sometimes necessary.

The manufacturer has to sign his products with the CE-Marking. With the
CE-Marking the manufacturer confirms the accordance with the different
EEC Directives. The CE-Marking is absolutely necessary to sell the
products in the EEC.
Below you find the EEC Directives concerning our products.
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS + WEEE 2002/95/EC + "002/96/EC

Quality Control System


Since November 1991 Benedict GmbH has been certified according to
the quality control system NORM EN ISO 29001
29001. The target of the ISOcertification is, to grant the customer the quality of the performance of
his supplier, who is audited in accordance with this standard.

Country

North America

Switzerland

Russia

China

State deputy or private examination


(state admitted)

UL
Canada, USA

SEV

GOST

CCC

all switchgear

all switchgear

all switchgear

Label marking
of examination boards

Listed
Component

Duty of approvals

all switchgear

Explanations for choice and supply of low voltage switchgear in Canada and USA
Marking of auxiliary contacts
At several devices in UL-data are two voltages for auxiliary contacts
mentioned (e. g.: 600 volts at same potential, 150 volts at different
potentials). That means, if the voltage is higher than 150 volts, the control
voltage applied to input terminals must be at the same potential.
Marking of
auxiliary contacts
according to
CSA and UL

Max. rated values per pole


Voltage
Current
Make
Break
V
A
A

Cont.
Current
A

Contact
Rating
Code
Designation

Heavy Duty
(HD or HVY DTY)

AC 120
AC 240
AC 480
AC 600

60
30
15
12

6
3
1,5
1,2

10
10
10
10

A150
A300
A600
A600

DC 125
DC 250
DC 600

2,2
1,1
0,4

2,2
1,1
0,4

10
10
10

N150
N300
N600

AC 120
AC 240
AC 480
AC 600

30
15
7,5
6

3
1,5
0,75
0,6

5
5
5
5

B150
B300
B600
B600

DC 125
DC 250
DC 600

1,1
0,55
0,2

1,1
0,55
0,2

5
5
5

P150
P300
P600

AC 120
AC 240
AC 480
AC 600

15
7,5
3,75
3

1,5
0,75
0,375
0,3

2,5
2,5
2,5
2,5

C150
C300
C600
C600

DC 125
DC 250
DC 600

0,55
0,27
0,1

0,55
0,27
0,1

2,5
2,5
2,5

Q150
Q300
Q600

AC 120
AC 240

3,6
1,8

0,6
0,3

1
1

D150
D300

DC 125
DC 250

0,22
0,11

0,22
0,11

1
1

R150
R300

AC 120

1,8

0,3

0,5

E150

Standard Duty
(SD or STD DTY)

Low voltage switchgear for auxiliary circuits (e. g. contactor relays, control
units, auxiliary contacts in general) usually approved for "Heavy Duty" or
"Standard Duty" UL and besides these marked with the admissible max.
voltage or with short codes (see table).
Discernment at UL-Standards
Recognized Component
Industrial Control Equipment

Listed
Industrial Control Equipment

UL issues yellow "Guide cards"


with Guide- and File-No.

UL issues white "Guide cards"


with Guide- and File-No.

Devices have permission to be


marked with
on the label

Devices have to be marked


with the
"UL-Listing Mark"

Devices as components approved for


"factory wiring":
devices for employment in control
panels, when they are selected,
mounted and wired according to
the charging conditions by skilled
worker.

Devices approved for "field wiring",

Valid UL-Standards:
UL 508 "Standard for Industrial
Control Equipment"
(partly limited)

Valid UL-Standards:
UL 508 "Standard for Industrial Control
Equipment" (unlimited)

a) devices for employment


in control panels, when
they are mounted and
wired by skilled worker.
b) devices for retail in USA

Are devices approved as "Listed Equipment"


for using as "Recognized Component"

the approval is also valid


.

D677E

Approvals
Country

North America

Switzerland

UL

SEV

Europe

Russia
GOST

China

CENELEC
CB-Certificates

Type
Mini Contactors, Reversing Contactors K1 and Accessories
K1-07D..(=)
K1-07L..(=)
K1-07F..(=)

o
-

o
o

o
o
o

o
o
-

o
o
-

K1-09D..(=)
K1-09L..(=)
K1-09F..(=)

o
-

o
o

o
o
o

o
o
-

o
o
o

o
o
-

K1-12D..(=)

K1W09D01(=)
K1W12D01(=)
K1W09L01(=)

o
o
-

o
o
o

o
o
o

HK.., HKM..
RC-K1

o
o

o
o

o
-

Contactor Relays Series K3 and KG3


K3-07A..(=)
K3-07D..(=)

o
o

o
o

KG3-07..

Contactors Series K3
K3-10N..(=)
K3-14N..(=)
K3-18N..(=)
K3-22N..(=)

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

K3-24A..(=)
K3-32A..(=)
K3-40A..(=)

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

K3-50A..(=)
K3-62A..(=)
K3-74A..(=)

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

K3-90A..(=)
K3-115A..(=)

o
o

o
o

o
o

K3-151A..(=)
K3-176A..(=)

o
o

o
o

K3-210A..(=)
K3-260A..(=)
K3-316A..(=)

x
x
x

o
o
o

K3-450A..(=)
K3-550A..(=)

o
o

o
o

K3-700A..(=)
K3-860A..(=)
K3-1000A..(=)
K3-1200A..(=)

o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

Contactors DC-operated Series KG3


KG3-10.., -14..
KG3-18.., -22..
KG3-24.., -32..
KG3-40..

o
o
o
o

Capacitor Contactors Series K3


K3-18NK..
K3-24K..
K3-32K..

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

K3-50K..
K3-62K..
K3-74K..
K3-90K..
K3-115K..

o
o
o
o
o

o
o
o
o
o

o
o
o
-

o
o
o
o
o

o
o
o
-

HN.., HTN..
HA..
HB..
K2-DK, K2-SK

o
o
o
o

o
o
o
o

o
o
o
-

o
o
-

o
o
o
-

HKA.., HKT..
HKF22

o
-

o
o

Aux. contacts

o In standard version approved

D677E

x In test

- Not provided for test till now

Approvals
Country

North America

Switzerland

UL

SEV

Europe

Russia
GOST

China

CENELEC
CB-Certificates

Type
Accessories
K2-T..E, -A
K2-TP
K2-L

o
o

o
o
o

K2-IN.
K2-UN.

o
o

o
o

K2-IM
K2-E
VG-K2

o
-

o
o
o

RC-K3

Reversing Contactors , Serie KW3


KW3-10
KW3-14
KW3-18
KW3-22

o
o
o
o

o
o
o
o

KW3-24
KW3-32
KW3-40

o
o
o

o
o
o

D.O.L. Starters
P1..

Thermal Overload Relays


U3/32
U3/42
U3/74

o
o
o

o
o
o

o
o
o

o
o
o

U12/16E
U12/16A
U12/16EM
U12/16EQ

o
-

o
o
o
o

o
o
o
o

o
o
o
o

U32
U60
U85

o
o
o

o
o
o

o
o
o

o
o
o

U180
U320

x
x

o
o

U840
U1250

o
o

Modular Contactors
R20
R25
R40
R63

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

K1R
RH11

o
o

o
o

o
o

o In standard version approved

- and

x In test

- Not provided for test till now

- Guide- and File-No.

These data are important for UL-inspecting engineers.


Devices

Guide-No.

File-No.

Kanada

USA

Kanada

USA

Contactors
Reversing Contactors
Control Relays, Accessories

NLDX7
NLDX7
NKCR7

NLDX
NLDX
NKCR

NLDX8
NKCR8

NLDX2
NKCR2

E41502
E41502
E66273

Thermal Overload Relays


Cam Switches
Circuit Breakers as Manual Motor Controller

NKCR7
NLRV7
NLRV7

NKCR
NLRV
NLRV

E66273

Circuit Breakers as Combination Motor Controller


Bus Bar Assemblies
Accessories

NKJH7
NLRV7
NKCR7

NKJH
NLRV
NKCR

E197641
E129916
E66273

E129916

D677E

Technical Information
Degree of protection acc. to IEC 60947-1
Protection ratings are prefixed by the internationally agreed letters IP
followed by two digits.

2 nd
digit

Short description

Definition

1 st digit:
2 nd digit:

Protected against
dripping water

Dripping water (vertically falling drops)


shall have no harmful effect.

Protected against
dripping water
when tilted
up to 15

Vertically dripping water shall have no


harmful effect when the enclosure is tilted
at any angle up to 15 from its normal
position.

Protected against
spraying water

Water falling as a spray at an angle up


to 60 from the vertical shall have no
harmful effect.

Protected against
splashing water

Water splashed against the enclosure


from any direction shall have no harmful
effect.

Protected against
water jets

Water protected by a nozzle against the


enclosure from any direction shall have
no harmful effect.

Protected against
heavy seas

Water from heavy seas or water


projected in powerful jets shall not
enter the enclosure in harmful
quanties.

Protected against
the effects of
immersion

Ingress of water in a harmful quantity


shall not be possible when the
enclosure is immersed in water under
standard conditions of pressure and
time.

Protected against
submersion

No ingress of water.

Pertains to solid objects


Pertains to water.

1 st
digit

Short description

Definition

Protected against
solid objects
greater than 50 mm

Excludes solid objects exceeding 50 mm


in diameter and protects against contact
with live and moving parts by a large body
surface such as a hand (but not against
deliberate access).

2L

Protected against
solid objects
greater than
12,5 mm and
against contact by
standard test finger

Excludes solid objects exceeding


12,5 mm in diameter and protects against
contact with live and moving parts by a
standard test finger or similar objects
not exceeding 80 mm in length.

Protected against
solid objects
greater than 2,5mm

Excludes solid objects exceeding 2,5 mm


in diameter or thickness.

Protected against
solid objects
greater than 1 mm

Excludes solid objects exceeding 1 mm


in diameter or thickness.

Dust protected

Prevents ingress of dust in quantities


and locations that would interfere with
the intended operation of the equipment.

Dust tight

Prevents ingress of dust.

Terminal markings acc. to EN50011

Resistance to climatic conditions acc. to IEC60068

Auxiliary contacts of AC contactors and contacts of contactor relays and


thermal overload relays are particularly marked. The terminal markings of
normally-open contacts are printed as positive figures, they of normallyclosed contacts as negative figures.
This gives a clear indication of the function of the contacts.
The figure below illustrates the determination of terminal markings for
contactors with auxiliary contact blocks.

Open-type devices are climate-resistant in the constant climate according


to IEC60068-2-3 (this is a climate with an ambient temperature of 40C and
an atmospheric humidity of 90 to 95%).
Enclosed devices are climate-resistant in an alternating climate according
to IEC 68-2-30 (this is a moist alternating climate with a 24-hour cycle
between climates with an ambient temperature of 25C, and an atmospheric
humidity of 95 to 100% and an ambient temperature of 40C, and an
atmospheric humidity of 90 to 96% in the presence of condensation during
rises in temperature).
Data are valid up to an altitude of 2000m above sea level.

Sequence number

Function number

The complete terminal marking according to EN


50011 and EN 50012 results from the sequence
numbers on the contactor relay or ac contactor
(2., 3.) and the function numbers on the auxiliary
contact blocks (e. g. .1, .2, or .3, .4).

D677E

Short circuit protection


Back up fuses should be used to protect contactors and starters against
short circuits. For starters the device with the smaller admissible fuse at
the main and at the control circuit (contactor or thermal overload) determines
the fuse size.
After a short circuit devices have to be checked for correct operation.
Disconnect power before proceeding with any work on the equipment!

Technical Information
Mounting positions of contactors
K1-..

K(G)3-07 to K3-115, R..

K3-151.. to K3-1200..

Terminal screws
Devices
Type

Kind of connection
Screw with
Screw with
washer
clamp box

Screw
w. nut

Screw driver

Tightening torque

Nm

lb. inch

Mini Contactors, all conductors

K1-..

M3,5

Pz2

0,8 - 1,4

7 - 12

M3,5

Pz2

0,8 - 1,4

7 - 12

K(G)3-10.. to K3-22..
K(G)3-24.. to K3-40..
K3-50.. to K3-74..

M3,5
-

M5
M6

Pz2
Pz2
Pz3

0,8 - 1,4
2,5 - 3
3,5 - 4,5

7 - 12
22 - 26
31 - 40

K3-90, K3-115

M8

4mm hex socket

4 - 6,5

35 - 57

K3-116.. to K3-176..
K3-210.. to K3-316..
K3-450.. to K3-700..

M8
M10
M12

17
35
60

150
315
540

K3-860..
K3-1000.., K3-1200..

M14
M12

75
60

675
540

Auxiliary conductor
K(G)3-10 to K3-22

M3,5

Pz2

0,8 - 1,4

7 - 12

Coil conductor
K(G)3-10 to K3-1200

M3,5

Pz2

0,8 - 1,4

7 - 12

M3,5
M3,5

Pz2
Pz2

0,8 - 1,4
0,8 - 1,4

7 - 12
7 - 12

U12/16

M4

Pz2

1,2 - 1,8

11 - 16

U3/32
U3/42
U3/74

M3,5
M5
-

M6

Pz2
Pz2
Pz3

0,8 - 1,4
2,5 - 3
3,5 - 4,5

7 - 12
22 - 26
31 - 40

UAT21
UAT22
UAT23

M4
M4
M5

Size 3, 4
Size 3, 4
Size 3, 4, 5

1,2 - 1,8
1,2 - 1,8
2,5 - 3

11 - 16
11 - 16
22 - 26

Auxiliary conductor
All devices

M3,5

Pz2

0,8 - 1,4

7 - 12

Contactor Relays, all conductors

K(G)3-07..
Contactors
Main conductor

Accessories
HK, HKM
HA, HN, K2-.., HB..
Thermal Overload Relays
Main conductor

Contactors for Distribution Boards


Conductors
R20, R25
R40, R63
K1R

M3,5

M3,5
M5
-

Pz1
Pz2
Pz2

0,8 - 1,4
2,5 - 3
0,8 - 1,4

7 - 12
22 - 26
7 - 12

Coil conductor
R20, R25
R40, R63
K1R

M3,5

M3
M3
-

Pz1
Pz2
Pz2

0,6 - 1,2
0,6 - 1,2
0,8 - 1,4

5 - 11
5 - 11
7 - 12

D677E

Mini Contactors

Mini Contactor Relays 4-pole


Auxiliary Contact Blocks

Interface Contactor Relays

D677E

Mini Contactors
Auxiliary Contact Blocks

10

Mini Contactors With Fast On Tab Connectors

12

Mini Contactors With Solder Pins

12

Coil voltages

12

Mini Reversing Contactors


Auxiliary Contact Blocks

14

Technical Data

16

Dimensions

20

Mini Contactor Relays 4-pole

AC Operated

Ratings

Therm. Contacts 2)
Distinc.
Number

AC15

Rated
Current
Ith
A
NO NC

230V
A

400V
A

Type

Additional
Contact

acc. to
Blocks
EN50011 Type

24
230
24VS
230VS
24VM
230VM

Coil voltage 1)
24V 50/60Hz
220-230V 50Hz
24V 50/60Hz w. protection 3)
220-230V 50Hz w. protection 3)
24V 50/60Hz 24V= DC
220-240V 50/60Hz 220V= DC
Pack Weight
pcs. kg/pc.

4-pole, With Screw Terminals


3

10

40E

1 HK..

K1-07D40 . . .

10

0,16

10

31E

1 HK..

K1-07D31 . . .

10

0,16

10

22E

1 HK..

K1-07D22 . . .

10

0,16

Auxiliary Contact Blocks For Contactor Relays


Ratings
AC15
230V 400V
A
A

Aux. Contact Blocks

Thermal
Rated
Current
A

Contacts 2)
NO

NC

Type
Pack Weight
pcs. kg/pc.

3
3
3

2
2
2

10
10
10

1
2

1
2
-

HK11
HK02
HK20

10
10
10

0,04
0,04
0,04

3
3
3

2
2
2

10
10
10

4
2
-

2
4

HK40
HK22
HK04

10
10
10

0,04
0,04
0,04

HK11

HK02

HK20

HK40

HK22

HK04

42E
33Y
24Y

60E
51Y
42Y

80E
71Y
62Y

62E
53Y
44Y

44E
35Y
26Y

Wiring Diagrams

Distinc. Number according to EN50011


for Contactor Relay with Auxiliary Contact Block
K1-07D40
K1-07D31
K1-07D22

51E
42Y
33Y

Preferable combinations with distinctive letter "E" according to DIN EN 50011

1) Other coil voltages see page 12


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with built-in coil suppressor (varistor)
8

D677E

DC Solenoid Operated

Type

Coil voltage 1)
24V= DC
24
24VS 24V= DC with
protection 2)

Contacts 2)
Distinc.
Number
acc. to
NO NC EN50011

Additional
Contact
Blocks
Type

Pack
pcs.

Weight
kg/pc.

Wiring Diagrams

4-pole, With Screw Terminals, Coil 2,5W


K1-07D40= ...

40E

1 HK..

10

0,19

K1-07D31= ...

31E

1 HK..

10

0,19

K1-07D22= ...

22E

1 HK..

10

0,19

4-pole, With Screw Terminals, Coil 1,5W, 19 to 30V DC with suppressor


K1-07D40= 24VR

10

0,20

K1-07D31= 24VR

10

0,20

K1-07D22= 24VR

10

0,20

3)

1) Other coil voltages on request


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with integrated coil suppressor (Transient Voltage Suppressor Diode)

D677E

Mini Contactors

AC Operated
Power Ratings

Rated
Current

AC2, AC3
380V
400V
660V
415V
690V
kW
kW

AC1
690V
A

Aux. Contacts2)
Built-in Additional

NO NC

Coil voltage 1)
24
24V 50/60Hz
230
220-230V 50Hz
24VS 24V 50/60Hz w. protection 3)
230VS 220-230V 50Hz w. protection 3)
24VM 24V 50/60Hz 24V= DC
230VM 220-240V 50/60Hz 220V= DC
Pack Weight

W
pcs.
kg/pc.

Type

Type

3-pole, With Screw Terminals


4
5,5

4
5,5

20
20

1
1

1 HKM..
1 HKM..

K1-09D10 . . .
K1-12D10 . . .

10
10

0,16
0,16

4
5,5

4
5,5

20
20

1
1

1HK..
1HK..

K1-09D01 . . .
K1-12D01 . . .

10
10

0,16
0,16

1HK..
1HK..

K1-09D00-40 . . .
K1-12D00-40 . . .

10
10

0,16
0,16

4-pole, With Screw Terminals


4
5,5

4
5,5

20
20

Auxiliary Contact Blocks for Contactors K1-..


Ratings
AC15
230V
A
3
3
3
Aux. Contact Blocks

400V
A

Thermal
Rated
Current
A

2
2
2
HKM11

10
10
10

Contacts 2)

Type
Pack
pcs.

NO NC
1
2

HKM11
HKM02
HKM22

1
2
2

Weight
kg/pc.

10
10
10

0,04
0,04
0,04

HKM02

HKM22

HK11

HK02

HK40

HK22

Contactors with Auxiliary Contact Block


Contacts according to EN50012
21
K1-..D10

12

32

Contacts according to DIN EN50005


K1-..D01
K1-..D00-40
-

12
11

03
02

41
40

23
22

Wiring Diagrams

Prefer combinations according to EN50012

Suppressor Units for Contactors K1-..


Type

Voltage Range
V
12 - 48V AC/DC
48 - 127V AC/DC
110 - 250V AC/DC

1600nF / 22 Ohm
680nF / 270 Ohm
220nF / 2200 Ohm

Pack
pcs.

RC-K1 24
RC-K1 110
RC-K1 230

10
10
10

1) Other coil voltages see page 12


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with built-in coil suppressor (varistor)
10

D677E

Weight
kg/pc.
0,01
0,01
0,01

DC Solenoid Operated

Type

Coil voltage 1)
24V= DC
24
24VS 24V= DC with
protection 3)

Aux. Contacts 2)
Additional
Built
Additional Overload
in
Relay
see
page102
NO NC
Type

Pack
pcs.

Weight
kg/pc.

Wiring Diagrams

3-pole, With Screw Terminals, Coil 2,5W


K1-09D10= . . .
K1-12D10= . . .

1
1

1 HKM..
1 HKM..

U12/16..K1
U12/16..K1

10
10

0,19
0,19

K1-09D01= . . .
K1-12D01= . . .

1
1

1 HK..
1 HK..

U12/16..K1
U12/16..K1

10
10

0,19
0,19

U12/16..K1
U12/16..K1

10
10

0,19
0,19

4-pole, With Screw Terminals, Coil 2,5W


K1-09D00-40= . . .
K1-12D00-40= . . .

3-pole, With Screw Terminals, Coil 1,5W, 19 to 30V DC with suppressor


K1-09D10=24VR

U12/16..K1

10

0,20

K1-09D01= 24VR -

U12/16..K1

10

0,20

3)

1) Other coil voltages on request


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with integrated coil suppressor (Transient Voltage Suppressor Diode)
D677E

11

Mini Contactors

AC Operated
Power Ratings

Rated
Current

AC2, AC3
380V
400V
660V
415V
690V
kW
kW

AC1
690V
A

Aux. Contacts2)
Built
Additional
in

NO NC

Type

Type

Coil voltage 1)
24
24V 50/60Hz
230
220-230V 50Hz
24VS 24V 50/60Hz w. protection 2)
230VS 220-230V 50Hz w. protection 2)
24VM 24V 50/60Hz 24V DC
230VM 220-240V 50/60Hz 220V DC
Pack Weight

W
pcs.
kg/pc.

3-pole, with Fast On Tab Connectors 1 x 6,3mm or 2 x 2,8mm


4

16

1 HKM..

K1-09F10 . . .

10

0,16

16

1 HK..

K1-09F01 . . .

10

0,16

3-pole, with Solder Pins 1,15 for Printed Circuit Applications


4

16

K1-09L10 . . .

10

0,16

16

K1-09L01 . . .

10

0,16

10

0,16

4-pole, with Solder Pins 1,15 for Printed Circuit Applications


4

16

K1-09L00-40 . . .

Suffix
to
contactor
type
e.g.
K1-09D10 230

Voltage Marking

Rated Control Voltage Us

at the coil
for
for
50Hz
60Hz
V
V

range
for 50Hz
min.
max.
V
V

Coil voltages for AC operated contactors


Suffix
to
contactor
type
e.g.
K1-09D10 24
12
24
42
48

Voltage Marking

Rated Control Voltage Us

at the coil
for
for
50Hz
60Hz
V
V

range
for 50Hz
min.
max.
V
V

12
24
42
48

12
24
42
48

90
95
100

100
95-100
100

100
105-110
110-115

105
110
180

105-110
110-115
200

115-120
120-125
200

11
22
38,5
48

for 60Hz
min.
max.
V
V

12
24
42
50

12
24
42
48

12
24
42
52

200
210
220
230

200
205-215
210-220
220-230

200-220
220-230
220-240
230-250

195
205
210
220

205
215
220
230

200
220
220
230

220
230
240
250

90
95
100

100
100
105

100
105
110

105
110
115

105
110
185

110
115
200

115
120
200

120
125
210

240
400
500
550

230-240
380-400
475-500
525-550

400-440
520-545
600

230
380
475
525

240
400
500
550

250
400
520
570

260
440
545
600

Standard voltages in bold type letters


Operating range of magnet-coils: 0,85 x Us (min. value of rated
control voltage) up to 1,1 x Us (max. value of rated control voltage)
Coil not exchangeable

1) Other coil voltages see page 12


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with built-in coil suppressor (varistor)
12

for 60Hz
min.
max.
V
V

D677E

DC Solenoid Operated

Type

Coil voltage 1)
24V= DC
24
24VS 24V= DC with
protection 3)

Aux. Contacts 2)
Additional
Built
Additional Overload
in
Relay
see
page102
NO NC
Type

Pack
pcs.

Weight
kg/pc.

Wiring Diagrams

3-pole, with Fast On Tab Connectors 1 x 6,3mm or 2 x 2,8mm


K1-09F10= . . .

1 HKM..

U12/16..K1

10

0,19

K1-09F01= . . .

1 HK..

U12/16..K1

10

0,19

3-pole, with Solder Pins 1,15 for Printed Circuit Applications


K1-09L10= . . .

10

0,19

K1-09L01= . . .

10

0,19

4-pole, with Solder Pins 1,15 for Printed Circuit Applications


K1-09L00-40= . . .

10

0,19

1) Other coil voltages on request


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with integrated coil suppressor (Transient Voltage Suppressor Diode)
D677E

13

Mini Reversing Contactors, Mechanical Interlocked

AC1

Aux. Contacts2)
Built-in Additional
on left
on right
hand side hand side
Contactor Contactor

690V
A

NO NC

Power Ratings Rated


Current
AC2, AC3
380V
400V 660V
415V 690V
kW
kW

AC Operated

K1
Type

K2
Type

Type

Coil voltage 1)
24V 50/60Hz
220-230V 50Hz
24V 50/60Hz w. protection 3)
220-230V 50Hz w. prot. 3)
24V 50/60Hz 24V DC
220-240V 50/60Hz 220V DC
Pack Weight
pcs.
kg/pc.

24
230
24VS
230VS
24VM
230VM

3-pole, with Screw Terminals


4
5,5

4
5,5

20
20

1
1

HKM11V
HKM11V

HKM11X
HKM11X

K1W09D01MC . . .
K1W12D01MC . . .

1
1

0,32
0,32

4
5,5

4
5,5

20
20

1
1

HKM..
HKM..

K1W09D10MC . . .
K1W12D10MC . . .

1
1

0,32
0,32

HKM..
HKM..

K1W09D00-40MC . .
K1W12D00-40MC . .

1
1

0,32
0,32

4-pole, with Screw Terminals


4
5,5

4
5,5

20
20

3-pole, with Solder Pins 1,15 for Printed Circuit Applications


4

16

K1W09L01MC . . .

0,32

16

K1W09L10MC . . .

0,32

Pack
pcs.

Weight
kg/pc.

Auxiliary Contact Blocks for Mini Reversing Contactors K1-..


Ratings
AC15
230V
A
3
3

400V
A
2
2

Aux. Contact BlocksAux. Contact Blocks

Thermal
Rated
Current
A
10
10

HKM11V

Contacts 2)

Type

NO NC
1
1

1
1

HKM11V
HKM11X

10
10

0,04
0,04

HKM11X

Wiring Diagrams

Reversing Starter Connector


For Reversing Starter Types, incl. Coil Connector

Type

K1W09D..MC, K1W12D..MC

K1W-VB

Pack
pcs.
1

1) Other coil voltages see page 12


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with built-in coil suppressor (varistor)
14

D677E

Weight
kg/pc.
0,01

DC Solenoid Operated

Type

Coil voltage 1)
24
24V= DC
24VS 24V= DC with
protection 2)

Additional
Overload
Relay
see
page102
Type

Pack
pcs.

K1W09D01MC= . . .
K1W12D01MC= . . .

U12/16..K1
U12/16..K1

1
1

0,32
0,32

K1W09D10MC= . . .
K1W12D10MC= . . .

U12/16..K1
U12/16..K1

1
1

0,32
0,32

U12/16..K1
U12/16..K1

1
1

0,32
0,32

Weight
kg/pc.

Wiring Diagrams

3-pole, with Screw Terminals

4-pole, with Screw Terminals


K1W09D00-40MC= . .
K1W12D00-40MC= . .

3-pole, with Solder Pins 1,15 for Printed Circuits Applications


K1W09L01MC= . . .

0,32

K1W09L10MC= . . .

0,32

1) Other coil voltages on request


2) with integrated coil suppressor (Transient Voltage Suppressor Diode)

D677E

15

Mini Contactors
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Main Contacts

Type

Rated insulation voltage Ui

V AC

Making capacity Ieff

690

2)

690

1)

165

165

400V AC
500V AC
690V AC

A
A
A

100
90
80

100
90
80

100
90
80

100
90
80

20

16

16

20

kW
kW
kW
kW

7,9
8,3
13,8
14,3

6
6,5
11
11,5

6
6,5
11
11,5

7,9
8,3
13,8
14,3

16

12

12

16

kW
kW
kW
kW

6,3
6,7
11
11,5

4,5
5
8
8,5

4,5
5
8
8,5

6,3
6,7
11
11,5

2,5

2,5

2,5

Rated operational power of three-phase resistive loads


50-60Hz, cos = 1

230V
240V
400V
415V

230V
240V
400V
415V

Minimum cross-section of conductor at load with Ie (=Ith)

mm

220V
230V
240V

A
A
A

12
11,5
11

12
11,5
11

12
11,5
11

15
14,5
14

380-400V
415-440V
500V
660-690V

A
A
A
A

9
8
7
5

9
8
7
5

9
8
7
5

12
11
9
6,5

220-240V
380-440V
500-690V

kW
kW
kW

3
4
4

3
4
4

3
4
4

4
5,5
5,5

220V
230V
240V

A
A
A

12
11,5
11

12
11,5
11

12
11,5
11

15
14,5
14

380-400V
415-440V
500V
660-690V

A
A
A
A

9
8
7
5

9
8
7
5

9
8
7
5

12
11
9
6,5

220-240V
380-440V
500-690V

kW
kW
kW

3
4
4

3
4
4

3
4
4

4
5,5
5,5

1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
2) Suitable at 690V for pollution degree 2, Uimp = 6kV.
Pollution degree 3 Ui = 690V non-tracking of the printed circuit CTI 600
Pollution degree 3 Ui = 500V non-tracking of the printed circuit CTI 400
Pollution degree 3 Ui = 400V non-tracking of the printed circuit CTI 100

16

K1-12D..

165

Rated operational current Ie (=Ithe) at 60C, enclosed

Rated operational power of three-phase motors


50-60Hz

690

K1-09L..

1)

165

Rated operational power of three-phase resistive loads


50-60Hz, cos = 1

Utilization category AC4


Switching of squirrel cage motors, inching
Rated operational current Ie
open and enclosed

K1-09F..

Utilization category AC1


Switching of resistive load
Rated operational current Ie (=Ith) at 40C, open

Rated operational power of three-phase motors


50-60Hz

690

1)

at Ue = 690V AC

Breaking capacity Ieff


cos = 0,65

Utilization category AC2 and AC3


Switching of three-phase motors
Rated operational current Ie
open and enclosed

K1-09D..

D677E

Mini Contactors
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Main Contacts

Type

Utilization category DC1


Switching of resistive load
Time constant L/R 1ms
Rated operational current Ie

K1-09D..

K1-09F..

K1-09L..

K1-12D..

1 pole 24V
60V
110V
220V

A
A
A
A

20
20
5
0,6

16
16
5
0,6

16
16
5
0,6

20
20
5
0,6

3 poles in series 24V


60V
110V
220V

A
A
A
A

20
20
20
16

20
20
20
16

20
20
20
16

20
20
20
16

1 pole 24V
60V
110V
220V

A
A
A
A

20
5
1
0,15

16
5
1
0,15

16
5
1
0,15

20
5
1
0,15

3 poles in series 24V


60V
110V
220V

A
A
A
A

20
20
20
2

16
16
16
2

16
16
16
2

20
20
20
2

Utilization category DC3 and DC5


Switching of shunt motors
and series motors
Time constant L/R 15ms
Rated operational current Ie

Maximum ambient temperature


Operation

open
enclosed
open
enclosed

with thermal overload relay


Storage

C
C
C
C

-40 to +60 (+90) 1)


-40 to +40
-25 to +60
-25 to +40

-50 to +90

Short circuit protection


for contactors without thermal overload relay
Coordination-type "1" according to IEC 947-4-1
Contact welding without hazard of persons
max. fuse size

gL (gG)

40

40

40

40

Coordination-type 2 according to IEC 947-4-1


Light contact welding accepted
max. fuse size

gL (gG)

25

25

25

25

Contact welding not accepted


max. fuse size

gL (gG)

10

10

10

10

For contactors with thermal overload relay the


device with the smaller admissible backup fuse
(contactor or thermal overload relay) determines the fuse size.
Cable cross-sections
for contactors without thermal overload relay
main connector
Cables per clamp

solid or stranded
flexible
flexible with multicore cable end

mm
mm
mm

0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
2

solid or stranded

AWG

18 - 14

Frequency of operations z
Contactors without thermal overload relay

Mechanical life

AC operated
DC operated

Short time current


Power loss per pole
Resistance to shock according to IEC 68-2-27
Shock time 20ms sine-wave
AC operated
DC operated

Fast on
Solder connector
1x 6,3 x 0,8
1,15
or
2x 2,8 x 0,8
-

0,5 - 2,5
0,5 - 2,5
0,5 - 1,5
2
18 - 14

without load
AC3, Ie
AC4, Ie
DC3, Ie

1/h
1/h
1/h
1/h

10000
600
120
600

10000
600
120
600

10000
600
120
600

10000
700
150
700

Sx
Sx

106
106

5
15

5
15

5
15

5
15

10s-current

96

96

96

120

at Ie/AC3 400V

0,15

0,15

0,15

0,25

NO
NC

g
g

5
5

5
5

5
5

5
5

NO
NC

g
g

8
6

8
6

8
6

8
6

1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3

D677E

17

Mini Contactors
Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1
Auxiliary Contacts

Type

Rated insulation voltage Ui

V AC

Thermal rated current Ith to 690V


Ambient temperature

690

1)

690

1)

1)

690 2)

10
6

10
6

690

1)

0,5

0,5

0,5

0,5

0,5

0,5

220-240V
380-415V
440V

A
A
A

3
2
1,6

3
2
1,6

3
2
1,6

3
2
1,6

3
2
1,6

3
2
1,6

500V
660-690V

A
A

1,2
0,6

1,2
0,6

1,2
0,6

1,2
0,6

1,2
0,6

1,2
0,6

60V
110V
220V

A
A
A

2
0,4
0,1

2
0,4
0,1

2
0,4
0,1

2
0,4
0,1

2
0,4
0,1

2
0,4
0,1

Storage

open
enclosed

C
C
C

Short circuit protection


short-circuit current 1kA,
contact welding not accepted
max. fuse size
gL (gG) A
For contactors with thermal overload relay the
device with the smaller admissible control fuse
(contactor or thermal overload relay)
determines the fuse size.
Power consumption of coils
AC operated

DC operated

inrush
sealed

VA
VA
W

inrush
sealed

W
W

Operation range of coils


in multiples of control voltage Us

10
6

690 1)

HK..

at Ith

Maximum ambient temperature


Operation

10
6

690

K1-07L..(=)
K1-09L..(=)

A
A

Utilization category DC13


Rated operational current Ie

10
6

K1-07D..=
K1-09D..= K1-07D..= 24VR
K1-12D..= K1-09D..= 24VR K1-09F..(=)

40C
60C

Power loss per pole


Utilization category AC15
Rated operational current Ie

K1-07D..
K1-09D..
K1-12D..

10
6

-40 to +60 (+90) 3)


-40 to +40
-40 to +90

20

20

20

2,5
2,5

1,5
1,5

25
4-5
1,2
0,85 - 1,1

0,8 - 1,1

19 - 30V DC

20

20

20

25
4-5
1,2

25
4-5
1,2

2,5
2,5

2,5
2,5

0,85 - 1,1

0,85 - 1,1

Switching time at control voltage Us 10% 4) 5)


AC operated

make time
release time
arc duration

ms
ms
ms

15 - 25
8 - 25
10 -15

15 - 25
8 - 25
10 -15

15 - 25
8 - 25
10 -15

DC operated

make time
release time
arc duration

ms
ms
ms

15 - 19
8 - 25
10 -15

15 - 19
8 - 25
10 -15

15 - 19
8 - 25
10 -15

15 - 19
8 - 25
10 -15

0,5 - 2,5
0,5 - 2,5
0,5 - 1,5

0,5 - 2,5
0,5 - 2,5
0,5 - 1,5

0,5 - 2,5
0,5 - 2,5
0,5 - 1,5

18 - 14

18 - 14

18 - 14

Cable cross-section
all connectors

solid
flexible
flexible with multicore cable end

mm2
mm2
mm2

Clamps per pole


solid or stranded

AWG

Fast on Solder connector


1x 6,3 x 0,8
1,15
or
2x 2,8 x 0,8
-

2
18 - 14

1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
2) Suitable at 690V for pollution degree 2, Uimp = 6kV.
Pollution degree 3 Ui = 690V non-tracking of the printed circuit CTI 600
Pollution degree 3 Ui = 500V non-tracking of the printed circuit CTI 400
Pollution degree 3 Ui = 400V non-tracking of the printed circuit CTI 100
3) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced thermal rated current Ith to Ie /AC15
4) Summary switching time = release time + arc duration
5) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units).

18

0,5 - 2,5
0,5 - 2,5
0,5 - 1,5

D677E

Mini Contactors for North America


Data according to UL508
Main Contacts (cULus)

Type

Rated operational current "General Use"

Rated operational power of three-phase motors


at 60Hz (3ph)

Rated operational power of of AC motors


at 60Hz (1ph)

K1-09D.. K1-09F..
K1W09D01
15

15

K1-09L..
20
1
3
3

2
3
3

440-480V
550-600V

hp
hp

5
7

5
7

5
7

7
10

110-120V
200-208V
220-240V

hp
hp
hp

1
1

1
1

1
1

1
2

30/5

Rated voltage

V AC

600

600

600 1)

A600
Q600

A600
Q600

2
3
3

heavy pilot duty


standard pilot duty

100
400
100 - 400

600V
480V
240V

D677E

10

1
3
3

30/5

Ui

20

1
3
3

30/5

CTI - PWB

10

hp
hp
hp

A/kA

1) Pollution degree

HK..

110-120V
200-208V
220-240V

Fuse / Short-circuit current

Auxiliary Contacts (cULus)

K1-07D.. K1-12D..
K1W12D01

AC
DC

A600
Q600

30/5

600

600

600

A600
Q600

A600
Q600

A600
Q600

19

Mini Contactors
Dimensions
AC and DC operated
with screw terminals

with fast on terminals

K1-07D..
K1-09D..
K1-12D..

K1-07F..
K1-09F..

AC and DC operated
with solder connections

Auxiliary Contact Blocks

K1-07L..
K1-09L..

HK..

Reversing Contactors
K1W09D..MC
K1W12D..MC

K1W09L..MC

K1W09D..MC + U12/16E K1
K1W12D..MC + U12/16E K1

20

D677E

Contactor Relays

D677E

Contactor Relays 4-pole, AC Operated

22

Auxiliary Contact Blocks 1-pole

22

Contactor Relays 4-pole, DC Operated

23

Technical Data

24

Dimensions

26

21

Contactor Relays

AC Operated
Ratings

AC15
230V
A

Contacts
Therm. Built-in
Distinc.
Rated
Number
Current
acc. to
400V
A

Ith
A

NO NC

Additional
Contact
Blocks

Type

EN50011 Type

Coil voltage 1)
24V 50/60Hz
110V 50Hz 110-120V 60Hz
220-240V 50Hz 230-264V 60Hz
380-415V 50Hz 400-440V 60Hz
Pack Weight
pcs. kg/pc.

24
110
230
400

4-pole, contacts suitable for electronic circuits according to EN947-5-42)


4
4
4
4

Auxiliary Contact Blocks

2
2
2
2

10
10
10
10

4
3
2
-

1
2
4

40E
31E
22E
04E

max. 4
HN..

K3-07ND40
K3-07ND31
K3-07ND22
K3-07ND04

.
.
.
.

.
.
.
.

.
.
.
.

1
1
1
1

0,22
0,22
0,22
0,22

3)

Ratings Thermal Contacts 2)


AC15
Rated
230V 400V
Current
A
A
A

Type
NO NC

Pack
pcs.

EM LB

Weight
kg/pc.

1-pole, contacts suitable for electronic circuits according to EN947-5-42)


3
3
3
3

2
2
2
2

10
10
10
10

1
-

1
-

1
-

HN10
HN01
HN10U
HN01U

10
10
10
10

0,02
0,02
0,02
0,02

HA10
HA01

10
10

0,03
0,03

1-pole, for high switching capacity


6
6

3
3

25
25

1
-

Accessories see page 34 - 38

1) Other coil voltages see page 40


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) Technical Data see page 62
22

D677E

DC Operated
Type

Coil voltage 1)
24
24V DC
60
60V DC
110 110V DC
220 220V DC

Contacts
Built-in
Distinc.
Number
acc. to
NO NC

EN50011 Type

3W Coil power, for high switching capacity


KG3-07A40
KG3-07A31
KG3-07A22
KG3-07A04

.
.
.
.

.
.
.
.

.
.
.
.

4
3
2
-

1
2
4

Additional
Contact
Blocks
Pack
pcs.

Weight
kg/pc.

Wiring Diagrams

3)

40E
31E
22E
04E

max. 4
HN..
oder
HA..

1
1
1
1

0,53
0,53
0,53
0,53

A40, D40

A31, D31

3W Coil power, for electronic circuits


KG3-07D40
KG3-07D31
KG3-07D22
KG3-07D04

.
.
.
.

.
.
.
.

.
.
.
.

4
3
2
-

1
2
4

2)3)

40E
31E
22E
04E

max. 4
HN..

1
1
1
1

0,53
0,53
0,53
0,53

A22, D22

A04, D04

with double winding coil, for electronic circuits


K3-07ND40=
K3-07ND31=
K3-07ND22=
K3-07ND04=

.
.
.
.

.
.
.
.

.
.
.
.

4
3
2

1
2
-4

40E
31E
22E
04E

2)3)

max. 3
HN..

1
1
1
1

0,25
0,25
0,25
0,25

ND40=

ND31=

ND22=

ND04=

1) Other coil voltages on request


2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
3) with integrated coil suppressor (Transient Voltage Suppressor Diode)
D677E

23

Contactor Relays
Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1

Rated insulation voltage Ui

1)

Type

K3-07ND

V AC

690

690

690

690

10
6

10
6

20
16

10
6

10000
10

10000
10

10000
10

10000
50

Thermal rated current Ithto 690V


Ambient temperature
40C
60C

A
A

Frequency of operations z
Mechanical life

1/h
S x 106

Utilization category AC15


Rated operational
current Ie

Utilization category DC13


Rated operational
current Ie
per pole
Power consumption of coils
AC operated

DC operated

K3-07ND= KG3-07A

KG3-07D

220-240V
380-415V
440V

A
A
A

4
2
1,6

4
2
1,6

12
4
4

4
2
1,6

500V
660-690V

A
A

1,2
0,6

1,2
0,6

3
1

1,2
0,6

24-60V
110V
220V

A
A
A

3,5
0,5
0,1

3,5
0,5
0,1

8
1
0,1

3,5
0,5
0,1

inrush
sealed

VA
VA
W

30 - 45
7 - 10
2,6 - 3

inrush
sealed

W
W

75
2

3
3

3
3

0,85 - 1,1

0,8 - 1,1

0,8 - 1,1

0,8 - 1,1

8 - 16
5 - 13

8 - 16
5 - 13

65 - 85
20 - 30 3)

65 - 85
20 - 30 3)

Operation range of coils


in multiples of control voltage Us
Switching time at control voltage Us10%
make time ms
release time ms
Maximum ambient temperature
Operation
open
enclosed
Storage

C
C
C

Short circuit protection


short-circuit current 1kA,
contact welding not accepted
max. fuse size
gL (gG)

Cable cross-section
Connector

solid
flexible
flexible with multicore cable end

Magnet coil

solid
flexible
flexible with multicore cable end

-40 to +60 (+90) 2)


-40 to +40
-40 to +90

20

20

mm2
mm2
mm2

0,75 - 6
1-4
0,75 - 4

mm2
mm2
mm2

0,75 - 2,5
0,75 - 2,5
0,5 - 1,5

Clamps per pole

25

20

Connector
Clamps per pole
Magnet coil
Clamps per pole

solid
flexible

AWG
AWG

18 - 10
18 - 10
2

solid
flexible

AWG
AWG

14 - 12
18 - 12
2

Data according to UL508


Rated operational current
"General Use"
Rated operational voltage
Auxiliary Contacts

max.

heavy pilot duty

10

10

20

10

V AC

600

600

600

600

A600

A600

A600

A600

1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.
2) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced thermal rated current Ith according to Ie /AC15 3) with built-in coil suppressor

24

D677E

Contactor Relays
Position of Terminals
AC operated
K3-07ND22

DC operated with double wound coil


K3-07ND31

K3-07ND40

K3-07ND04

KG3-07A40
KG3-07D40

KG3-07A04
KG3-07D04

K3-07ND22=

K3-07ND31=

K3-07ND40=

K3-07ND04=

DC solenoid operated
KG3-07A22
KG3-07D22

KG3-07A31
KG3-07D31

D677E

25

Contactor Relays
Dimensions
AC operated

DC solenoid operated

K3-07ND..

KG3-07..

DC operated with double winding coil


K3-07ND.. =

Auxiliary contact blocks


HN10, HN01

26

HA10, HA01

D677E

Contactors

D677E

Contactor overview

28

Contactors 3-pole, AC Operated

30

Contactors 3-pole, DC Operated

31

Contactors 4-pole

32

Capacitor Switching Contactors

33

Auxiliary Contact Blocks


Snap-on Momentary Contacts
Additional Fourth Poles for Contactors

34

Pneumatic Timers
Electronic Timers On-delay
Electronic Timers Off-delay

35

Mechanical Interlocks
Latches
Additional Terminals, Parallel Connectors

36

Indicator Units
Fuse Holders
Suppressor Units

37

Interface
Terminal Covers
Mounting Parts, Marking System

38

Control Voltages

40

Spare Coils AC-operated


Feeder Groups

40

Spare Coils DC-operated


Spare Contacts

41

Technical Data

44

Dimensions

64

27

Contactors 3-pole
Up to 1200A AC3
Up to 1350A AC1
DIN-rail mounting up to AC3 115A
International Approvals
Data according to IEC 947 / EN 60947

Ratings
AC3 400V

Motor
380-400V
660-690V

AC1

690V at 40C

Type

K3-

Auxiliary contacts

14A

18A

22A

24A

4kW
5,5kW

5,5kW
7,5kW

7,5kW
10kW

11kW
10kW

11kW
15kW

25A

25A

32A

32A

50A

65A

24A00
-

10ND10 14ND10 18ND10 22ND10


1NO

Type

K3-

Auxiliary contacts
Cable cross-section
Solid
Flexible

10A

1NO

1NO

1NC

mm2
mm2

50A

62A

74A

90A

115A

22kW
30kW

30kW
37kW

37kW
45kW

45kW
55kW

55kW
55kW

80A

110A

120A

130A

160A

200A

32A00

40A00

50A00

62A00

74A00

15kW 18,5kW
18,5kW 18,5kW

90A00 115A00

Power consumption Inrush VA


of coils
hold VA
Operation range of coils

1NC

1NC

0,75 - 6
1-4

1,5 - 25
2,5 - 16

4 - 50
10 - 35

10 - 120
10 - 95

16
12
4

33 - 45
7 - 10
0,85 - 1,1

90 - 115
9 - 13
0,85 - 1,1

140 - 165
13 - 18
0,85 - 1,1

280
5
0,85 - 1,1

A
A
A

Mounting

35mm DIN-rail or base

Additional aux. contact blocks


Type
Front mounting
contacts

Additional aux. contact blocks


Type
Side mounting
contacts

40A

10ND01 14ND01 18ND01 22ND01


1NC

Auxiliary contact
Ith
40C
AC15 230V
400V

1NO

32A

HN10
1NO
f. low level
switching
-

HN01
1NC
f. low level
switching
-

HA10
1NO
25A Ith

HA01
1NC
25A Ith

HB11
1NO+1NC
f. low level
switching

2x DIN-rail
or base
max.
4 HN..
or
4 HA..
HB02
2NC
f. low level
switching

max.
7 HN..
or
7 HA..
max.
2 HB..

Overload Relay (thermal)


Single phase protection
Temperature compensation
Trip and alarm contacts

Type

U3/32
U12/16..K3

Number of Setting Ranges


from
Busbar sets

28

U3/74

U85

U3/42

16
0,12 - 30A

16
0,12 - 32A

4
10 - 42A

5
20 - 74A

2
60 - 120A

D677E

150A

175A

210A

260A

315A

450A

550A

700A

860A

1000A

1200A

75kW
90kW

90kW
110kW

110kW
160kW

132kW
210kW

160kW
250kW

250kW
375kW

300kW
475kW

400kW
630kW

500kW
700kW

580kW
850kW

680kW
1000kW

230A

250A

350A

450A

500A

600A

760A

1000A

1100A

1200A

1350A

151A00

176A00

210A00

260A00

316A00

450A22

550A22

700A22

860A22

1000A12

1200A12

busbar
30x6

busbar
30x6

busbar
30x6

2 x 16-120
2 x 16-120

2NO+2NC 2NO+2NC

busbar
30x5

busbar
40x6

350
350
5
5
0,85 - 1,1

360
5

360
5
0,85 - 1,1

2NO+2NC 2NO+2NC

busbar
50x8

busbar
50x8

1NO+2NC 1NO+2NC

busbar
50x10

10
3
2
360
5

800-950
9-11

busbar
50x10

10
3
2

800-950
1350-1600 1350-1600
9-11
21-25
21-25
0,85 - 1,1

2400
2400
70
70
0,85-1,1

base

HKT11
HKT22
1NO+1NC 2NO+2NC
max. 1 pc.

HKA11
1NO+1NC
max. 2 pcs.

HKF22
2NO+2NC
max. 1 pc.

U180

U320

U800

1
120 - 180A

2
144 - 320A

3
240 - 800A

integrated

integrated

D677E

SU840/550

HKB11
1NO+1NC
max. 2 pcs.

SU840/860

29

Contactors 3-pole

AC Operated
Ratings
AC2, AC3
380V
400V
660V
415V
690V
kW
kW

Rated
Current
AC1
690V
A

Aux. Contacts
Built-in Additional
see
page 34
NO NC

Typ
max. 4
HN.. or
HA..

4
4

5,5
5,5

25
25

1
-

5,5
5,5

7,5
7,5

25
25

1
-

10
10

32
32

1
-

11
11

10
10

32
32

11
15
18,5

15
18,5
18,5

22
30
37

Type

Coil voltage 1)
24V 50/60Hz
110V 50/60Hz
220-240V 50Hz
380-415V 50Hz Pack
pcs.

24
110
230
400
W

K3-10ND10 . . .
K3-10ND01 . . .

1
1

0,23
0,23

K3-14ND10 . . .
K3-14ND01 . . .

1
1

0,23
0,23

K3-18ND10 . . .
K3-18ND01 . . .

1
1

0,23
0,23

1
-

K3-22ND10 . . .
K3-22ND01 . . .

1
1

0,23
0,23

50
65
80

max. 4
HN.. or
HA..
and 2HB..

K3-24A00 . . .
K3-32A00 . . .
K3-40A00 . . .

1
1
1

0,48
0,48
0,48

30
37
45

110
120
130

max. 4 (3)2)
HN.. or
HA..
and 2HB..

K3-50A00 . . .
K3-62A00 . . .
K3-74A00 . . .

1
1
1

0,85
0,85
0,85

45
55

55
55

160
200

max. 7
HN.. or
HA..
and 2HB..

K3-90A00 . . . 3)
K3-115A00 . . . 3)

1
1

2,2
2,2

75
90

110
132

230
250

1 HKT..
and
2 HKA11

K3-151A00 . . .
K3-176A00 . . .

3)

1
1

4
4

110
132
160

160
210
250

350
450
500

K3-210A00 . . .
K3-260A00 . . .
K3-316A00 . . .

3)

1
1
1

7,2
7,2
7,2

250
300

375
475

600
760

2
2

2
2

K3-450A22 . . .
K3-550A22 . . .

1
1

13
13,5

400
500

630
700

1000
1100

2
2

2
2

K3-700A22 . . .
K3-860A22 . . .

1
1

26,5
27,6

580
680

850
1000

1200
1350

1
1

2
2

K3-1000A12 . . .
K3-1200A12 . . .

1
1

49
53

7,5
7,5

1 HKF22

2 HKB11

3)

3)
3)

1) Coil voltage range and other coil voltages see page 39


2) max. 3 HN.. or HA.. for DC-operated Contactors
3) with integrated coil suppressor
30

Weight
kg/pc.

D677E

DC Operated
Type

Coil voltage 1)
24 24V DC
48 48V DC
110 110V DC
W

Coil
power
inrush/
hold
W/W

Additional
Overload
Relay
see
page 102
Type

Wiring Diagram

Pack
pcs.

Weight
kg/pc.

1
1

0,53
0,53

1
1

0,53
0,53

.3)

KG3-10A10 . .
KG3-10A01 . . .3)

3/3
3/3

KG3-14A10 . . .3)
KG3-14A01 . . .3)

3/3
3/3

KG3-18A10 . . .3)
KG3-18A01 . . .3)

3/3
3/3

1
1

0,53
0,53

KG3-22A10 . . .3)
KG3-22A01 . . .3)

3/3
3/3

1
1

0,53
0,53

KG3-24A00 . . .3)
KG3-32A00 . . .3)
KG3-40A00 . . .3)

4/4
4/4
4/4

U3/32
U3/42
UAT..

1
1
1

0,57
0,57
0,57

K3-50A00= . . .
K3-62A00= . . .
K3-74A00= . . .

200/6
200/6
200/6

U3/74

1
1
1

0,9
0,9
0,9

K3-90A00 . . . 2)3)
K3-115A00 . . . 2)3)

280/5
280/5

U85

1
1

2,2
2,3

K3-151A00 . . . 2)3)
K3-176A00 . . . 2)3)

350/5
350/5

U180

1
1

4
4

K3-210A00 . . . 2)3)
K3-260A00 . . . 2)3)
K3-316A00 . . . 2)3)

360/5
360/5
360/5

U320

1
1
1

7,2
7,2
7,2

K3-450A22 . . . 2)
K3-550A22 . . . 2)

800/10
800/10

U800
+SU840/550

1
1

13
13,5

K3-700A22 . . . 2)
K3-860A22 . . . 2)

1500/20
1500/20

U800
+SU840/860

1
1

26,5
27,6

K3-1000A12= . . .
K3-1200A12= . . .

2100/60
2100/60

1
1

49
53

U3/32
U12/16E
U12/16EQ
UAT21

Coil Circuits
see page 41
Terminal Markings
A10

A01

A00

A00=

A00

A22

A12

1) Other coil voltages on request


2) Contactors K3-90A00 ... to K3-860A22 ... are AC and DC operated
K3-90A00 230 to K3-860A22 230 can be used at 220VDC and 220-240V 50/60Hz
3) with integrated coil suppressor
D677E

31

Contactors 3-pole

DC Operated
Ratings
AC2
AC3
380V
400V 660V
415V 690V
kW
kW

Rated
Current
AC1

Aux. Contacts
Built-in Additional
see
page 34

690V
A

NO NC Type

4
4

5,5
5,5

25
25

1
-

5,5
5,5

7,5
7,5

25
25

1
-

32
32

1
-

32
32
50
65
80

7,5 10
7,5 10
11
11

10
10

11
15
18,5
15
18,5 18,5

Type

24
60
110
220

Coil voltage 1)
24V= DC
60V= DC
110V= DC
220V= DC
Pack Weight Wiring Diagram
pcs. kg/pc.

K3-10ND10= . . .
K3-10ND01= . . .

1
1

0,25
0,25

K3-14ND10= . . .
K3-14ND01= . . .

1
1

0,25
0,25

K3-18ND10= . . .
K3-18ND01= . . .

1
1

0,25
0,25

1
-

K3-22ND10= . . .
K3-22ND01= . . .

1
1

0,25
0,25

K3-24A00= . . .
K3-32A00= . . .
K3-40A00= . . .

1
1
1

0,55
0,55
0,55

max. 3
HN..
or
HA..

max. 4
HN.. or
HA..
+ 2HB..

Contactors 4-pole

A01=

... A00=

AC Operated
Ratings
AC2 AC1
AC3
380V
400V
415V 400V
kW
kW

AC1

Aux. Contacts
Built-in Additional
see
page 34

690V
A

NO NC Type

25
25

7,5 22
22
11

32
32

11
31
34,5
15
18,5 34,5

45
50
50

4
17,5
5,5 17,5

Rated
Current

Type

24
110
230
400

Coil voltage 2)
24V 50/60Hz
110V 50/60Hz
220-240V 50Hz
380-415V 50Hz
Pack Weight Wiring Diagram
pcs. kg/pc.

max. 4
HN.. or
HA..

K3-10NA00-40 . . .
K3-14NA00-40 . . .

1
1

0,22
0,22

K3-18NA00-40 . . .
K3-22NA00-40 . . .

1
1

0,22
0,22

max. 4
HN..
or
HA..

K2-23A00-40 . . .
K2-30A00-40 . . .
K2-37A00-40 . . .

1
1
1

0,65
0,65
0,65

22
30

55
69

80
100

max. 6
HN.. or
HA..

K2-45A00-40 . . .
K2-60A00-40 . . .

1
1

1,1
1,1

55
75
90

139
159
173

200
230
250

1HKT..
+
2xHKA11

K3-116A00-40 . . .3)
K3-151A00-40 . . .3)
K3-176A00-40 . . .3)

1
1
1

4,7
4,7
4,7

110
132
160

242
310
346

350
450
500

K3-210A00-40 . . .3)
K3-260A00-40 . . .3)
K3-316A00-40 . . .3)

1
1
1

8
8
8

Latch for Contactors 4-pole see page 36

1) Other coil voltages on request


2) Coil voltage range and non-standard coil voltages see page 39
3) with integrated coil suppressor
32

A10=

D677E

A00-40

Capacitor Switching Contactors


for use with reactive or non-reactive capacitor banks
Rated Operational Power at 50/60Hz
Ambient Temperature
50C
60C
380V
415V
660V
380V
415V
400V
440V
690V
400V
440V
kVAr
kVAr
kVAr
kVAr
kVAr

660V
690V
kVAr

12,5 0-13
0-12,5
0-12,5
12,5 0-13

0-20
0-20

Aux.
Contacts
Built-in Add.

Type
Coil voltage 1)
220-240V 50Hz
Pack Weight
pcs. kg/pc.

230

NO NC pcs.
1
-

- 1 2)
1 1 2)

K3-18NK10 . . .
K3-18NK01 . . .

1
1

0,34
0,34

3 3)
3 3)

K3-24K00 . . .
K3-32K00 . . .

1
1

0,62
0,62

3 3)
3 3)
3 3)

K3-50K00 . . .
K3-62K00 . . .
K3-74K00 . . .

1
1
1

1,0
1,0
1,0

33-80
80 36-82 57-120 33-75 36-77 57-120 1006) 36-1036) 57-1486) 33-906) 36-936) 57-1486) 33-100

6 5)
6 5)

K3-90K00 . . .
K3-115K00 . . .

1
1

2,3
2,3

10-20
20
25
10-25

0-20
0-20

10,5-22 17-33
10,5-27 17-41

0-12,5
0-12,5

0-13
0-13

10-20
10-25

10,5-22 17-33
10,5-27 17-41

20-33,3
20-33,3 23-36
33,3 23-36 36-55
50 23-53 36-82
20-50
20-50 23-53
754) 23-754) 36-1204) 20-60 23-64
20-75

36-55
36-82
36-100

Specification: Contactors K3-..K are suitable for switching low-inductive and low loss capacitors in capacitor banks
(IEC70 and 831, VDE 0560) without and with reactors.
Capacitor switching contactors are fitted with early make contacts and damping resistors, to reduce the value of make
current <70 x Ie.
Operating Conditions: Capacitor switching contactors are protected against contact welding for a prospective making
current of 200 x Ie.

Technical Data acc. to IEC 947-4-1, IEC 947-5-1, EN 60947-4-1, EN 60947-5-1, VDE 0660
Type

K3-18K

K3-24K

K3-32K

K3-50K

K3-62K

K3-74K

K3-90K

K3-115K

Max. frequency of operations z

1/h

120

120

120

120

120

80

80

80

Contact life

S x 103
S x 103

250
400

150
300

150
300

150
300

150
300

120
200

120
200

120
200

non reactive capacitor banks


reactive capacitor banks

Rated operational current Ie


AC6b

at 50C
at 60C

A
A

0-18
0-18

14-28
14-28

14-36
14-36

30-48
30-48

30-72
30-72

30-108
30-87

50-115
50-108

50-144
50-130

Rated operational current Ith


AC1

at 50C
at 60C

A
A

32
32

45
40

60
55

100
90

110
100

120
110

155
145

190
170

Overload factor
acc. to EN 61921: 30% min.

at 50C
at 60C

%
%

78
78

60
43

67
53

108
88

53
39

11
26

35
34

32
31

from / to

35 / 63

50 / 80

63 / 100

160/200

160/250

Fuses gL (gG)
Typical
Circuit Diagram

80 / 160 125 / 160 160/200

Wiring Diagram for


Quick Discharge Resistors
Make sure that the current of the discharge
resistors is not higher than the rated current
(AC1) of the auxiliary contacts
Mounting instructions:
In the area of capacitor switching contactors,
difficulty inflammable and self-extinguishing
materials shall be used only, because
abnormal temperatures within the area of the
resistor spirals cannot be excluded.

1) Coil voltage range and non-standard coil voltages see page 39


2) 1 HN.. or HA.. snap-on
3) 2HB.. for side mounting and 1 HN.. or HA.. snap-on
4) Consider the max. thermal current of the contactor K3-74A: Ith 130A
5) 2 HB.. on the left or right side and 4 HN.. or HA.. snap-on
6) Consider the min. cross-section of conductor at max. load
D677E

33

Auxiliary Contact Blocks for contactors K(G)3-07.. to K3-115.., type HN.. for low level switching 1)
Rated
AC15
230V
A

Operational Current
AC15 AC1
400V 690V
A
A

Type

Contacts
NO

NC

EM

LB

Pack

Weight

pcs.

kg/pc.

3
3

2
2

10
10

1
-

HN10
HN01

10
10

0,02
0,02

3
3

2
2

10
10

1
-

HN10U
HN01U

10
10

0,02
0,02

6
6

3
3

25
25

1
-

HA10
HA01

10
10

0,03
0,03

Auxiliary Contact Block for contactors K3-24.. to K3-115.., for low level switching 1)
Rated
AC15
230V
A
3
3

Operational Current
AC15 AC1
mounting:
400V 690V
1 HB.. on left side
A
A
and 1 HB.. on right side
2
2

10
10

Contacts
NO
1
-

Type

NC
1
2

Pack

Weight

pcs.

kg/pc.

HB11
HB02

10
10

Type

Pack

Weight

pcs.

kg/pc.

0,02
0,02

Auxiliary Contact Blocks for contactors K3-116.. to K3-1200


Rated
AC15
230V
A

Operational Current
AC15 AC1
400V 690V
A
A
For contactors

Contacts
NO

NC

3
3
3

2
2
2

10
10
10

K3-116 to K3-316 top


K3-116 to K3-316 top
K3-116 to K3-316 outside

1
2
1

1
2
1

HKT11
HKT22
HKA11

1
1
1

0,04
0,05
0,05

6
6

3
3

16
16

K3-200 to K3-860 2)
K3-1000, K3-1200 inside

2 2)
1

2
1

HKF22
HKB11

1
1

0,12
0,17

Snap-on Momentary Contacts for K(G)3-07.. to K3-115.. for low level switching1)
Rated
AC15
230V
A
3
3

Operational Current
AC15 AC1
400V 690V
A
A
Specification
2
2

10
10

Contacts

manual operated
manual operated

NO

NC

1
-

Type

HTN10
HTN01

Pack

Weight

pcs.

kg/pc.

10
10

0,02
0,02

Terminal Blocks for contactors K(G)3-07.. to K3-115.. and K2-..


Specification
2 terminals interconnected
2 terminals insulated

Thermal Current Ith


A
26
26

Type

Pack
pcs.

K2-DK
K2-SK

10
10

1)Contacts suitable for electronic circuits, according to IEC60947-5-4 for rated voltage 24V DC
(test ratings 17V DC, 5mA) Positively guided contacts
Technical data see page 62
2) Contact travel of make contacts adjustable, see page 63
34

D677E

Weight
kg/pc.
0,02
0,02

Pneumatic Timer for contactors K(G)3-07.. to K(G)3-40.. and K2-07 to K2-16


Timer must be snapped onto the contactor, mechanically operated by the contactor and occupies 4 add-on spaces. The contacts of the timer
switch delayed tothe contacts of the contactor.
Type

Contacts
Function

Pack

Weight

pcs.

kg/pc.

Time Range
s

NO NC NO NC

On-delay
On-delay

0,1 - 40
10 - 180

1
1

1
1

K2-TP40DE
K2-TP180DE

1
1

0,09
0,09

Off-delay
Off-delay

0,1 - 40
10 - 180

1
1

1
1

K2-TP40IA
K2-TP180IA

1
1

0,09
0,09

Electronic Timer On-delay for contactors K(G)3-07.. to K3-115.. and K2-..


Timer will be connected with the contactor coil, can be snapped onto the contactor and occupies 2 add-on spaces. Contactor switches On-delay.

Wiring Diagram

Type

Rated Current
AC15
A

24 - 60V AC/DC
100 - 250V AC/DC

1 - 30
1 - 30

0,75
0,75

K2-TE30 60
K2-TE30 250

1
1

0,08
0,08

24 - 60V AC/DC
100 - 250V AC/DC

10 - 180
10 - 180

0,75
0,75

K2-TE180 60
K2-TE180 250

1
1

0,08
0,08

24 - 60V AC/DC
100 - 250V AC/DC

30 - 600
30 - 600

0,75
0,75

K2-TE600 60
K2-TE600 250

1
1

0,08
0,08

Operational
Voltage
V

Time Range

Timing Chart
Control voltage

LED
brown

Contactor

Pack

Weight

pcs.

kg/pc.

Operation Range
Time repeat accuracy
Recovery time (typical)

0,8 - 1,1 x Us
1%
50ms

Voltage Drop after the time delay te


(Control voltage 24V: use contactor with 20V-coil)
Max. inrush current (peak value)

<3V
25A <10ms

Duty Cycle
Ambient temperature
Short circuit protection

100%
-40o - +60oC
2A

Electronic Timer Off-delay for contactors K(G)3-07.. to K3-74.. and K2-..


Timer will be connected with the contactor coil, can be snapped onto the contactor and occupies 2 add-on spaces. Contactor switches Off-delay.

Wiring Diagram

white

Type

Rated Current
AC15
A

24 - 60V AC
100 - 120V AC
200 - 250V AC

1 - 30
1 - 30
1 - 30

0,75
0,3
0,15

K2-TA30 60
K2-TA30 120
K2-TA30 250

1
1
1

0,08
0,08
0,08

24 - 60V AC
100 - 120V AC
200 - 250V AC

10 - 180
10 - 180
10 - 180

0,75
0,3
0,15

K2-TA180 60
K2-TA180 120
K2-TA180 250

1
1
1

0,08
0,08
0,08

24 - 60V AC
100 - 120V AC
200 - 250V AC

30 - 600
30 - 600
30 - 600

0,75
0,3
0,15

K2-TA600 60
K2-TA600 120
K2-TA600 250

1
1
1

0,08
0,08
0,08

Operational
Voltage
V

Timing Chart

brown

Time Range

Operation Range

D677E

Weight

pcs.

kg/pc.

0,8 - 1,1 x Us

Time repeat accuracy


Contact S Min. start time
Recovery time (typical)

1%
15ms
15ms

Voltage Drop
LED Max. inrush current (peak value)
Contactor
Duty Cycle
Ambient temperature
Short circuit protection

<0,7V
25A <10ms

Utilization Category AC15

Pack

100%
-40o - +40oC
2A
24 - 60V
0,75A

100 - 120V 200 - 250V


0,3A
0,15A
35

Interface for contactors K3-07.. to K3-74.. and K2-07.. to K2-60..


Input
Voltage Ue

Power
Consumption

Rated Current Ie AC15


250V AC
400V AC

24V DC
0,35W
0,75A
Amplifier element for contactor control
by programmable controller

0,5A

Type

Pack
pcs.

K2-IM

Weight
kg/pc.
0,03

Fuse Holders for contactors K(G)3-07.. to K3-115.. and K2-..


Specifications

Rated Voltage

Type

Fuse holder for fuse 5x20mm (max. 6,3A)


Fuses are not included.

250V AC

K2-F

Pack
pcs.
1

Weight
kg/pc.
0,02

Rectifier with Fuse Holder for contactors K(G)3-07.. to K3-115.. and K2-..
Specifications

Rated Voltage

Type

with built-in rectifier 1A


with built-in rectifier 3A

250V AC
250V AC

K2-RF1
K2-RF3

Pack
pcs.
1
1

Weight
kg/pc.
0,03
0,03

Latch for contactors K(G)3-07.. to K3-74.. and K2-..


Type

with NC aux. contact


power consumption max. 30VA

For Contactors

24
110
230
400

Coil voltage
22-26V 50/60Hz
100-120V 50/60Hz
210 -250V 50/60Hz
360-440V 50/60Hz
Pack
pcs.

Weight
kg/pc.

K3-07 to K3-22, K2-07 to K2-16

K2-L22 . . .

0,08

K3-24 to K3-40, K2-23 to K2-37, KG3-10 to KG3-40

K2-L40 . . .

0,08

K3-50 to K3-74, K2-45 to K2-60

K2-L74 . . .

0,08

Technical data see page 62


Latch for Contactors K3-200 to K3-860 on request

Indicator Units for contactors K(G)3-07.. to K3-115.. and K2-..


Specifications

Voltage
Range

Type

Pack
pcs.

Weight
kg/pc.

Coil Current Indicator


Indicator, green (LED)
24 - 660V AC/DC
Coil Current Indicator,
Indicator red (LED)
24 - 660V AC/DC
To connect in series with the contactor coil. In case of coil
interruption the indication goes out. Voltage drop appr. 2 volts

K2-ING
K2-INR

10
10

0,02
0,02

Voltage Indicator
Indicator, clear (glow-disc. l.)
220 - 415V AC/DC
Voltage Indicator
Indicator, red (LED)
24 - 120V AC/DC
To connect parallel to the contactor coil. In case of applied
voltage the indication also lights at coil interruption.

K2-UN
K2-UNR

10
10

0,02
0,02

For Type

Type

Snap-On Adapter

K2-DK, K2-SK, K2-TE, K2-TA


K2-IM, K2-F, K2-RF
K2-IN., K2-UN.

36

Specification

for snap-on mounting of


accessories on 35mm
DIN-rail acc. DIN EN 50022

Pack
pcs.

K2-SM

10

D677E

Weight
kg/pc.
0,009

Additional 4th Poles for contactors K3-315.. to K3-1200


For Ccontactors

Type

Thermal Current Ith


A

K3-315, K3-450, K3-550


K3-315, K3-450, K3-550
K3-450, K3-550
K3-700, K3-860
K3-700, K3-860
K3-1000, K3-1200

Pack
pcs.

Weight
kg/pc.

325
500
760

NP325
NP500
NP760

1
1
1

0,7
1,3
1,4

500
1000
1000

NP501
NP1000
NP1001

1
1
1

1,3
1,6
1,6

Mechanical Interlocks

1) clamps for mounting incl.

Interlocks contactor with contactor


Type
Type

Mounting

Type

K3-07 to K3-40
KG3-07 to KG3-22
KG3-24 to KG3-40
K2-07 to K2-37

K3-07 to K3-40
KG3-07 to KG3-22
KG3-24 to KG3-40
K2-07 to K2-37

horizontal

LG10889 1)

10

0,006

K3-24 to K3-74
K2-23 to K2-60

K3-50 to K3-74
K2-45 to K2-60

horizontal

LG10890 1)

0,010

K3-90, K3-115

K3-90, K3-115

horizontal

LG11478 1)

0,010

K65 to K110

K65 to K110

horizontal

LG8511

0,076

K3-116 to K3-316

K3-116 to K3-316

horizontal

LG11223H

0,06

K3-315 to K3-550
K3-315 to K3-550
K3-450, K3-550
K3-450, K3-550

K3-315 to K3-550
K3-315 to K3-550
K3-700, K3-860
K3-700, K3-860

horizontal
vertical
horizontal
vertical

LG10400H
LG10400V
LG10399H
LG10399V

1
1
1
1

0,8
0,8
1,6
0,9

K3-700, K3-860
K3-700, K3-860
K3-700, K3-860
K3-700, K3-860

K3-700, K3-860
K3-700, K3-860
K3-1000, K3-1200
K3-1000, K3-1200

horizontal
vertical
horizontal
vertical

LG10402H
LG10402V
LG10401H
LG10401V

1
1
1
1

1,5
0,9
1,9
1,6

K3-1000, K3-1200
K3-1000, K3-1200

K3-1000, K3-1200
K3-1000, K3-1200

horizontal
vertical

LG10403H
LG10403V

1
1

1,8
1,5

Pack
pcs.

Weight
kg/pc.

Terminal Covers for terminal protection according to DIN 57106, VBG 4


For Contactors

Specification

Type

K65 to K110 (spare part)

for 6 terminals

LG9333

0,045

K3-151, K3-176 3-pole


K3-116 to K3-176 4-pole
K3-210, K3-260, K3-316

for 3 terminals
for 4 terminals
for 3 terminals

LG10404
LG104044
LG11457

1
1
1

0,12
0,14
0,14

K3-200
K3-315, K3-450

for 3 terminals
for 3 terminals

LG10405
LG10406

1
1

0,18
0,28

K3-550
K3-700
K3-860

for 3 terminals
for 3 terminals
for 3 terminals

LG10407
LG10408
LG10409

1
1
1

0,34
0,39
0,49

Pack
pcs.

Weight
kg/pc.

Additional Terminals
For Contactors

Type
Cable Cross-sections to clamp mm
solid or
flex. with multistranded
flexible
core cable end

Additional Terminal Single Pole, with fingertouch protection


K(G)3-10 to K(G)3-22 0,75 - 10
0,75 - 6
0,75 - 6
K2-09 to K2-16
K3-151 to K3-176
16 - 120 + 16 - 95
Additional Terminal Single Pole, set with 3 pieces
K3-50 to K3-74,
4 - 35
6 - 25
4 - 25
K2-45, K2-60
K3-50 to K3-74
10 - 70
16 - 50
10 - 35
K2-45, K2-60
D677E

Pack

Weight

pcs.

kg/pc.

LG9339

0,009

LG11224

0,10

LG9030

0,052

LG9031

0,170

37

Parallel Connectors
For Contactors

Type
Cable Cross-sections to clamp mm
solid or
flex. with multistranded
flexible
core cable end

Parallel Connectors, 3 Poles Parallel


Current-carrying capacity: 2,5 x AC1-value of the contactor
K(G)3-10 to K(G)3-22 terminal hole for screw M5
K2-09 to K2-16
K2-23 to K2-37
4 - 35
6 - 25
4 - 25
Parallel Connectors, 4 Poles Parallel
Current-carrying capacity: 3,2 x AC1-value of the contactor
K(G)3-10 to K(G)3-22 terminal hole for screw M5
K2-09 to K2-16

Pack

Weight

pcs.

kg/pc.

LG9241

50

0,004

LG5587

10

0,022

LG7360

10

0,006

Suppressor Units
Voltage Range
V

Type

Mounting

Pack
pcs.

Weight
kg/pc.

Varistor for contactors K3-07 to K3-74, K2-07 to K2-60


12 - 24V AC/DC
to snap on the contactor
24 - 48V AC/DC
to snap on the contactor
110 - 230V AC/DC
to snap on the contactor
250 - 415V AC/DC
to snap on the contactor

VG-K2/24
VG-K2/48
VG-K2/230
VG-K2/400

10
10
10
10

0,02
0,02
0,02
0,02

RC-units for contactors K3-07 - K3-74, K2-09 - K2-60


12 - 48V AC/DC
to snap
1600nF / 22 Ohm
48 - 127V AC/DC
on the
680nF / 270 Ohm
110 - 230V AC/DC
contactor
220nF / 2200 Ohm

RC-K3 N24
RC-K3N 110
RC-K3 N230

10
10
10

0,01
0,01
0,01

RC-units for contactors K1-07 to K110


24 - 48V AC/DC
universal
110 - 250V AC/DC
(fixing band,
250 - 415V AC
adhesive strip)

RC-AD22/48
RC-AD047/230
RC-AD047/400

5
5
5

0,02
0,02
0,02

220nF / 100 Ohm


470nF / 470 Ohm
470nF / 22 Ohm

Mounting Parts
Specification

Type

Description

For Type

Clamp,
no distance

K3-07 to K3-115 To join contactors


K2-07 to K2-37 without distance,
2 pieces required

P426-1

50

0,001

Clamp,
7mm distance

K3-07 to K3-115 To join contactors


K2-07 to K2-37 with 7mm distance,
2 pieces required

P418-1

10

0,002

Clamp,
K3-07 to K3-115 To join contactors
12mm distance K2-07 to K2-37 with 12mm distance,
2 pieces required

P807-1

10

0,002

Clamp
asymmetric

P785-1

10

0,002

K3-07 to K3-40
To join contactors
with K3-50 - K3-74 with 12mm distance,
2 pieces required

Pack
pcs.

Weight
kg/pc.

Marking System for contactors K3-07.. to K3-115.., K2-.. and aux. contact blocks HN and HA

38

Description

Specification

Type

Pack
pcs.

Marking Plate
Marking Plate
Marking Plate

2-section without marking, divisible


3-section without marking, divisible
4-section without marking, divisible

P487-1
P971-1
P245-1

100
100
100

0,025
0,038
0,050

Marking Plate

marked, choice of K1...K32

P245-K..

100

0,013

D677E

Weight
kg/100pc

Coil voltages for AC operated contactors


Type-suffix for coil-types K6/.. to K45/...
for contactor-types K3-07.. to K3-74

Type-suffix for coil-types K85/... and K110/...


for contactor-types K85 to K110

Suffix
to
contactor
type

Suffix
to
contactor
type

to
coil
type

Voltage Marking

Rated Control Voltage Us

at the coil
for
for
50Hz
60Hz
V
V

range
for 50Hz
min. max.
V
V

6
6,6
7,3

41.6
41.6,6
41.7,3

6
6,6
7,3

8
9
10

41.8
41.9
41.10

8
9
10

11
12
13,2

41.11
41.12
41.13

11
12
13,2

14,5
16
18

41.14
41.16
41.18

14,5
16
18

20
24
25

41.20
4.24
41.25

20
24
25

27
31
33

41.27
41.32
41.33

36
40
42

6
6,6
7,3

6,6
7,3
8

for 60Hz
min. max.
V
V
6,6
7,3
8

7,3
8
9

8
9
10

9
10
11

9
10
11

11
12
13,2

12
13,2
14,5

12
13,2
13,2 14,5
14,5 16

14,5
16
18

16
18
20

16
18
20

18
20
22

24

20
22
24

22
24
27

22
24
27

24
27
30

27
32
36

32
36
36

27
30
33

30
33
36

30
33
36

33
36
39

41.36
41.40
4.42

36
42
42

42
42
48

36
39
42

39
42
47

39
42
47

42
47
52

48
55
60

41.48
41.55
41.60

48
55
60

48
60

44
52
58

48
58
65

48
58
65

52
65
72

65
75
85

41.65
41.75
41.85

65
75
85

65
72
80

72
80
90

72
80
90

80
90
100

90
110
115

41.90
4.110
41.115

100
100
110 110-120
115
125

90
100
110

100
110
122

100
110
122

110
122
135

127
140
150

41.127
41.140
41.150

127
140
150

122
135
150

135
150
165

135
150
165

150
165
180

165
180
200

41.165
41.180
41.200

165 180-208
180-210 200-240
200-2301) 220-240

165 180
180 210
200 2301)

180
200
220

208
240
240

230
254
270

4.230
41.254
41.270

220-240 230-264
254
277
270

220
240
264

230
264
290

264
290
315

300
320
345

41.300
41.320
41.345

300
320
345-4001) 380-4401)

290 315
315 345
345 4001)

315 345
345 380
380 4401)

400
415
440

4.400
41.415
41.440

380-415 400-440
415-440 440-480
440-480 480-500

380
400
440

415
440
480

400
440
480

460
480
530

480
500

41.480
41.500

480-500 530-580
500-550 550-600

480
500

530
550

530
550

580
600

550

41.550

550-600

550

600

600 (650)

12

600

Standard voltages in bold type letters

240
264
290

10
11
12

to
coil
type

20
24
42

4.20
4.24
4.42

110
230
400

4.110
4.230
4.400

Voltage Marking

Rated Control Voltage Us

at the coil
for
for
50Hz
60Hz
V
V

range
for 50Hz
min. max.
V
V

20
24
42

for 60Hz
min. max.
V
V

24

20
24
42

22
27
47

24
29
50

26
32
56

110-120
277
220-240
380-415 460-480

110
220
380

122
240
415

132
264
455

146
288
498

Type-suffix for coil-types K3-1200/..


for contactor-types K3-1000.. to K3-1200..
110
230
400

4.110
4.230
4.400

110-115
220-230
380-400

110
220
380

115
230
400

110
220
380

115
230
400

440

4.440

440

440

440

440

440

Coil voltages for AC and DC operated contactors


Type-suffix for coil-types K3-115/.. to K3-860/..
for contactor-types K3-90.. to K3-860..
Suffix
to
contactor
type

to
coil
type

Voltage Marking

Rated Control Voltage Us

at the coil
for
for
50/60Hz DC
V
V

range
for 50Hz
min. max.
V
V

for 60Hz
min. max.
V
V

24
48
110

4.24
4.48
4.110

24
48
110-120

24
48
110

22
44
110

24
48
120

22
44
110

24
48
120

230
400

4.230
4.400

220-240
380-415

220
-

220
380

240
415

220
380

240
415

Operating range of magnet-coils: 0,85 x Us (min. value of rated


control voltage) up to 1,1 x Us (max. value of rated control voltage)
With reduced control voltage range 0,9 up to 1,0 x Us at ambient
temperature 60 - 90C

1) Operating range of magnet-coils: 0,85 x Us (min. value of rated control voltage) up to 1,05 x Us (max. value of rated control voltage)

D677E

39

Spare Coils for AC operated contactors


Type

For Contactors

4.24
4.42
4.110
41.180
4.230
4.400

K3-07N.. up to K3-22N..
K3-07.. up to K3-22..
K2-07.. up to K2-16..

K10N/ . . .EUR
K3-6/ . . .
K6/ . . .

K3-24.. up to K3-40..
K2-23.. up to K2-37..
K3-50.. up to K3-74.., K2-45.., K2-60..
K65.., K85..
K110..

10
10
10

0,053
0,040
0,040

K24/ . . .
K23/ . . .
K45/ . . .

1
1
1

0,085
0,085
0,110

K85/ . . .
K110/ . . .

1
1

0,215
0,220

Type

For Contactors
K3-150.., K3-175..
K3-1000.., K3-1200..

without feeder group 2)

Coil voltage 1)
24V 50Hz
42V 50Hz
110V 50Hz
180V 50Hz, 220V 60Hz
220-240V 50Hz
380-415V 50Hz
Pack Weight
pcs.
kg/pc.

4.110
4.230
4.400
W

Coil voltage 1)
110V 50Hz, 110-115V 60Hz
220-230V 50Hz
380-400V 50Hz
pcs.
kg/pc.

K3-175/ . . .
K3-1200/ . . .

1
1

0,38
3,12

Spare Coils for AC and DC operated contactors


Type

For Contactors

4.24
4.110
4.230
4.400
W

Coil voltage 1)
24V 50/60Hz / 24V DC
110-120V 50/60Hz / 110V DC
220-240V 50/60Hz / 220V DC
380-415V 50/60Hz
pcs.
kg/pc.

K3-90.., K3-115..
K3-151.., K3-176..
K3-210.., K3-316..

with feeder group


with feeder group
with feeder group

K3-115/ . . .
K3-176/ . . .
K3-316/ . . .

1
1
1

0,30
0,68
0,68

K3-450.., K3-550..
K3-700.., K3-860..

without feeder group 2)


without feeder group 2)

K3-550/ . . .
K3-860/ . . .

1
1

1,63
2,44

Spare Feeder Groups for contactors K3-450.. to K3-860..


In case of changing control voltage,
change coil and feeder group too

For Contactors

for coils

K3-450.., K3-550..
K3-700.., K3-860..

K3-550/4...
K3-860/4..

Type

110
230
400

Coil voltage 1)
110-120V 50/60Hz / 110V DC
220-240V 50/60Hz / 220V DC
380-415V 50/60Hz
Pack Weight
pcs.
kg/pc.

K3-550/FG . . .
K3-860/FG . . .

1
1

1) Coil voltage range and non-standard coil voltages see page 39


2) In case of changing control voltage, change coil and feeder group too
40

D677E

0,33
0,54

Spare Coils for DC operated contactors


Aux. Contact Block
for double winding coil

Type

For Contactors

47.24
47.110
47.220

Coil voltage 1)
24V DC
110V DC
220V DC

Pack
pcs.

Weight
kg/pc.

K10N/ . . .
K3-6/ . . .
K6/ . . .

1
1
1

0,052
0,042
0,042

K3-24..= up to K3-40..=
HN01X
K2-23..= up to K2-37..=
HN01X
K3-50..= up to K3-74..=, K2-45..=, K2-60..= HN01Z

K24/ . . .
K23/ . . .
K45/ . . .

1
1
1

0,090
0,090
0,115

K65..=, K85..=
K110..=

K85/ . . .
K110/ . . .

1
1

0,220
0,225

K3-07N..= up to K3-22N..=
K3-07..= up to K3-22..=
K2-07..= up to K2-16..=

HN01U
HN01U
HN01U

Type
For Contactors
K3-1000..=, K3-1200..=

without feeder group 2)

43.110
43.220
W

Coil voltage 1)
110V DC
220V DC

K3-1200/ . . .

pcs.
1

kg/pc.
3,12

Wiring Diagrams for Coil Circuit


AC operated,

DC operated
with double winding coil
K3-07..=
up to K3-22..=

K3-07..
up to K110..

AC and DC operated
with double winding coil
K3-90A00, K3-115A00
K3-151A00, K3-176A00
K3-210A00 to K3-316A00

DC operated
KG3..

AC and DC operated
with series resistor
K3-200A21
K3-315A21

K3-24..=
to
K3-74..=

K85..=
K110..=

AC and DC operated
with series resistor
K3-450.. up to K3-860..

DC operated
with DC coil
K3-1000.., K3-1200..

Adjustable dropout operating time for K3-450.. to K3-860..:


150-200ms:
Wiring see above (delivery standard)
500-1000ms: Jumper device "Z"
approx. 20ms: Special wiring see package folder

AC operated
with DC coil
K3-1000.., K3-1200..

Contactor K3-1000.., K3-1200..:


For control voltages up to 125V
NC contacts 21-22 and 11-12 are connected parallel,
for higher voltages contacts are connected in series (delivery standard).

1) Other coil voltages on request


2) In case of changing control voltage, change coil and feeder group too
D677E

41

Spare Contacts

42

Main Contacts
for Contactors

Type

K85..
K110..

EK85/1
EK110/1

3
3

0,235
0,275

K3-150..
K3-151..
K3-175..

EK3-150/10
EK3-151/10
EK3-175/10

1
1
1

0,32
0,16
0,32

K3-176..
K3-200..
K3-210..

EK3-176/10
EK3-200/10
EK3-210/10

1
1
1

0,16
0,18

K3-260..
K3-315..
K3-316..

EK3-260/10
EK3-315/10
EK3-316/10

1
1
1

0,34

K3-450..
K3-550..
K3-700..

EK3-450/10
EK3-550/10
EK3-700/10

1
1
1

0,35
0,35
0,85

K3-860..
K3-1000..
K3-1200..

EK3-860/10
EK3-1000/10
EK3-1200/10

1
1
1

1,0
1,4
1,4

Pack
pcs.

D677E

Weight
kg/pc.

Approximate Values for three-phase Motors


Motor Full Load Currents
Approximate values of motor F.L.C. and minimum "slow blow" respectively "gL" short-circuit fuse

kW

Range
according to
BS for
415V
F.L.C.
PS~hp hp cos %

220-230V Value
Motor of fusing at
motor start
D.O.L. YD
F.L.C.
A
A
A

240V
Value
Motor of fusing at
motor start
D.O.L. YD
F.L.C.
A
A
A

380-400V Value
Motor of fusing at
motor start
D.O.L. YD
F.L.C.
A
A
A

415V
Value
Motor of fusing at
motor start
D.O.L. YD
A
A
A

500V
Value
Motor of fusing at
motor start
F.L.C. D.O.L. YD
A
A
A

660-690V Value
Motor of fusing at
motor start
F.L.C. D.O.L. YD
A
A
A

0,06
0,09
0,12
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
2,5
3
3,7
4
5,5
7,5
8
11
12,5
15
18,5
20
22
25
30
37
40
45
51
55
59
75
90
110
129
132
147
160
184
200
220
250
257
295
315
355
400

0,08
0,12
0,16
0,24
0,34
0,5
0,75
1
1,5
2
3
3,4
4
5
5,5
7,5
10
11
15
17
20
25
27
30
34
40
50
54
60
70
75
80
100
125
150
175
180
200
220
250
270
300
340
350
400
430
483
545

0,38
0,55
0,76
1,1
1,4
2,1
2,7
3,3
4,9
6,2
8,7
9,8
11,6
14,2
15,3
20,6
27,4
28,8
39,2
43,8
52,6
64,9
69,3
75,2
84,4
101
124
134
150
168
181
194
245
292
358
420
425
472
502
590
626
700
803
826
948
990
-

0,35
0,5
0,68
1
1,38
1,93
2,3
3,1
4,1
5,6
7,9
8,9
10,6
13
14
18,9
24,8
26,4
35,3
40,2
48,2
58,7
63,4
68
77,2
92,7
114
123
136
154
166
178
226
268
327
384
393
432
471
541
589
647
736
756
868
927
-

0,22
0,33
0,42
0,64
0,88
1,22
1,5
2
2,6
3,5
5
5,7
6,6
8,2
8,5
11,5
15,5
16,7
22
25
30
37
40
44
50
60
72
79
85
97
105
112
140
170
205
242
245
273
295
340
370
408
460
475
546
580
636
710

2
2,5
3,5
5
6,5
7,5
11
14
21
28
35
40
55
66
80
105
135
165
200
230
260
325
385
450
500
-

0,16
0,24
0,33
0,46
0,59
0,85
1,2
1,48
2,1
2,6
3,8
4,3
5,1
6,2
6,5
8,9
11,9
12,7
16,7
19
22,5
28,5
30,6
33
38
44
54
60
64,5
73,7
79
85,3
106
128
156
184
186
207
220
259
278
310
353
363
416
445
483
538

0,7
0,9
1,1
1,5
2
2,9
3,5
4,9
6,7
9
13
17,5
21
25
33
42
49
60
82
98
118
140
170
215
268
337
366
410

Motor
rating

1
1,5
2
3
4
5
7,5
10
15
20
25
30
40
50
60
80
100
125
150
175
200
250
300
350
400
-

0,7
0,7
0,7
0,7
0,7
0,72
0,75
0,8
0,83
0,83
0,83
0,83
0,84
0,84
0,84
0,85
0,86
0,86
0,86
0,86
0,86
0,86
0,86
0,87
0,87
0,87
0,87
0,87
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,88
0,89
0,89

59
60
61
61
62
64
69
74
77
78
81
81
81
82
82
83
85
85
87
87
87
88
88
89
89
90
90
90
91
91
91
91
91
92
92
92
92
93
93
93
93
93
93
93
93
93
95
96

1
2
2
2
4
4
4
6
10
10
16
16
20
25
25
35
35
50
63
63
80
100
100
100
125
125
160
160
200
200
250
250
315
400
500
500
500
630
630
800
800
1000
1000
1000
1250
1250
-

1
2
2
2
2
4
4
4
6
10
10
16
16
20
20
25
35
35
50
50
63
80
80
80
100
125
160
160
160
200
200
250
250
315
400
500
500
630
630
630
800
800
1000
1000
1000
1250
-

1
1
2
2
2
2
2
2
4
2
4
4
4
4
6
4
6
6
10
10
16
10
16
10
20
16
25
16
25
20
35
25
35
35
35
35
50
50
63
50
80
63
80
63
80
80
100
80
100 100
125 100
160 125
160 160
200 160
200 200
200 200
250 200
315 250
315 315
400 400
500 400
500 500
630 500
630 630
630 630
800 630
800 800
1000 800
1000 800
1000 1000
1250 1000
-

The motor F.L.C. be valid for standard internal and surface cooled three-pole
motors with 1500 min-1. The fuses values be valid for the motor F.L.C. shown in the
table and D.O.L.-start: starting current max. 6x motor F.L.C., starting time max. 5s;
star-delta-start: starting current max. 2x motor F.L.C., starting time max. 15s. For

1
1
2
2
2
4
4
4
4
6
10
10
16
16
16
20
25
25
35
35
50
63
63
63
80
80
100
100
125
125
160
160
200
250
250
315
315
315
400
400
500
500
630
630
800
800
800
1000

1
1
2
2
2
2
2
4
4
4
6
10
10
10
10
16
20
20
25
35
35
50
50
50
63
63
80
100
100
100
125
125
160
200
250
250
250
315
315
400
400
500
500
630
630
630
800
800

4
4
6
10
16
16
20
25
35
35
50
63
80
100
100
160
200
200
250
315
315
400
500
630
630
-

4
4
4
6
10
10
16
16
25
35
50
50
63
80
100
125
160
200
250
250
315
400
400
500
630
-

1
1
1
1
2
2
4
4
4
4
6
6
10
16
16
16
20
20
25
35
35
50
50
50
63
63
80
80
100
100
125
125
160
160
200
250
250
250
315
315
315
400
500
500
500
630
630
630

1
1
1
1
2
2
2
2
4
4
6
6
10
10
10
10
16
16
20
25
25
35
35
50
50
50
63
63
80
80
100
100
125
160
200
200
200
250
250
315
315
400
400
400
500
500
630
630

2
2
2
4
4
6
6
10
16
16
25
25
35
35
50
63
63
80
125
125
160
200
200
250
315
400
500
500

2
2
2
2
4
4
4
6
10
10
16
20
25
35
35
50
63
63
100
125
125
160
200
250
315
400
400
500

motors with higher F.L.C., higher starting current and / or longer starting time, larger
short-circuit fuses are required.
The maximum admissible value is dependent on the switchgear respectively
thermal overload relay.

Approximate values of motor F.L.C. according to CSA and UL


Motor
rating
hp
1/2
3/4

1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
500

Motor F.L.C. at 110-120V


1-phase 2-phase 3-phase
A
A
A

Motor F.L.C. at 220-240V1)


1-phase 2-phase 3-phase
A
A
A

Motor F.L.C. at 440-480V


1-phase 2-phase 3-phase
A
A
A

9.8
13.8
16.0
20.0
24.0
34.0
56.0
80.0
100.0
135.0
-

4.9
6.9
8.0
10.0
12.0
17.0
28.0
40.0
50.0
68.0
88.0
110.0
136.0
176.0
216.0
-

2.5
3.5
4.0
5.0
6.0
8.5
14.0
21.0
26.0
34.0
44.0
55.0
68.0
88.0
108.0
-

4.0
4.8
6.4
9.0
11.8
16.6
26.4
38.0
48.0
72.0
94.0
118.0
138.0
180.0
226.0
-

4.4
6.4
8.4
12.0
13.6
19.2
30.4
44.0
56.0
84.0
108.0
136.0
160.0
208.0
260.0
-

2.0
2.4
3.2
4.5
5.9
8.3
13.2
19.0
24.0
36.0
47.0
59.0
69.0
90.0
113.0
133.0
166.0
218.0
-

2.2
3.2
4.2
6.0
6.8
9.6
15.2
22.0
28.0
42.0
54.0
68.0
80.0
104.0
130.0
145.0
192.0
248.0
312.0
360.0
480.0
602.0
-

1.0
1.2
1.6
2.3
3.0
4.2
6.6
9.0
12.0
18.0
23.0
29.0
35.0
45.0
56.0
67.0
83.0
109.0
135.0
156.0
208.0
-

1.1
1.6
2.1
3.0
3.4
4.8
7.6
11.0
14.0
21.0
27.0
34.0
40.0
52.0
65.0
77.0
96.0
124.0
156.0
180.0
240.0
302.0
361.0
414.0
477.0
590.0

Motor F.L.C. at 550-600V


1-phase 2-phase 3-phase
A
A
A
2.0
2.8
3.2
4.0
4.8
6.8
11.2
16.0
20.0
27.0
35.0
44.0
54.0
70.0
86.0
-

0.8
1.0
1.3
1.8
2.4
3.3
5.3
8.0
10.0
14.0
19.0
24.0
28.0
36.0
45.0
53.0
66.0
87.0
108.0
125.0
167.0
-

0.9
1.3
1.7
2.4
2.7
3.9
6.1
9.0
11.0
17.0
22.0
27.0
32.0
41.0
52.0
62.0
77.0
99.0
125.0
144.0
192.0
242.0
289.0
336.0
382.0
472.0

1) Determine the motor current for 200V and 208V by increasing the values for 220-240V at 200V about 15% and for 208V about 10%.

D677E

43

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

Type K(G)3-10 K(G)3-14 K(G)3-18 K(G)3-22 K(G)3-24 K(G)3-32 K(G)3-40 K3-50

Rated insulation voltage Ui

K3-62

K3-74

V AC

690

690

690

690

690

690

690

690

690

690

at Ue = 690V AC

200

200

200

200

400

500

500

700

900

900

Breaking capacity Ieff


400V AC
K2-09 to K3-22
cos= 0,65 500V AC
K3-24 to K3-1200 cos= 0,35 690V AC
1000V AC

A
A
A
A

180
150
100
-

180
150
100
-

200
180
150
-

200
180
150
-

380
300
260
-

400
370
340
-

400
370
340
-

600
500
400
-

800
700
500
-

800
700
500

690V

25

25

32

32

50

65

80

110

120

130

220V
230V
240V

kW
kW
kW

9,5
9,9
10,4

9,5
9,9
10,4

12,2
12,7
13,3

12,2
12,7
13,3

19,0
19,9
20,8

24,7
25,9
27,0

30,4
31,8
33,2

41,9
43,8
45,7

45,7
47,7
49,8

49,5
51,7
54,0

380V
400V
415V

kW
kW
kW

16,4
17,3
17,9

16,4
17,3
17,9

21,0
22,1
23,0

21,0
22,1
23,0

32,9
34,6
35,9

42,7
45,0
46,7

52,6
55,4
57,4

72,3
76,1
79,0

78,9
83,0
86,2

85,5
90,0
93,3

440V
500V
660V

kW
kW
kW

19,0
21,6
28,5

19,0
21,6
28,5

24,4
27,7
36,5

24,4
27,7
36,5

38,1
43,3
57,1

49,5
56,2
74,2

60,9
69,2
91,3

83,7
95,2
125,6

91,3
103,8
137,0

99,0
112,5
148,4

690V
1000V

kW
kW

29,8
-

29,8
-

38,2
-

38,2
-

59,7
-

77,6
-

95,5
-

131,3
-

143,2
-

155,2

690V

25

25

32

32

40

55

65

90

100

110

220V
230V
240V

kW
kW
kW

9,5
9,9
10,4

9,5
9,9
10,4

12,2
12,7
13,3

12,2
12,7
13,3

15,2
15,9
16,6

20,9
21,9
22,8

24,7
25,9
27,0

34,3
35,8
37,4

38,1
39,8
41,5

41,9
43,8
45,7

380V
400V
415V

kW
kW
kW

16,4
17,3
17,9

16,4
17,3
17,9

21,0
22,1
23,0

21,0
22,1
23,0

26,3
27,7
28,7

36,2
38,1
39,5

42,7
45,0
46,7

59,2
62,3
64,6

65,7
69,2
71,8

72,3
76,1
79,0

440V
500V
660V

kW
kW
kW

19,0
21,6
28,5

19,0
21,6
28,5

24,4
27,7
36,5

24,4
27,7
36,5

30,4
34,6
45,7

41,9
47,6
62,8

49,5
56,2
74,2

68,5
77,9
102,8

76,1
86,5
114,2

83,7
95,2
125,6

690V
1000V
Minimum cross-section of conductor
at load with Ie (=Ith)

kW
kW

29,8
-

29,8
-

38,2
-

38,2
-

47,7
-

65,7
-

77,6
-

107,4
-

119,4
-

131,3

10

16

25

35

50

50

Making capacity Ieff

1)

Utilization category AC1


Switching of resistive load
Rated operational current Ie (=Ith)
at 40C, open
Rated operational power
of three-phase resistive loads
50-60Hz, cos= 1

Rated operational current Ie (=Ithe)


at 60C, enclosed
Rated operational power
of three-phase resistive loads
50-60Hz, cos= 1

Utilization category AC2 and AC3


Switching of three-phase motors
Rated operational current Ie
open and enclosed

Rated operational power


of three-phase motors
50-60Hz

mm

220V
230V
240V

A
A
A

12
11,5
11

15
14,5
14

18
18
18

22
22
22

24
24
24

30
30
32

40
40
40

50
50
50

63
62
62

74
74
74

380-400V
415V
440V

A
A
A

10
9
9

14
14
14

18
18
18

22
22
22

24
23
23

32
30
30

40
40
40

50
50
50

62
62
62

74
74
74

500V
660-690V
1000V

A
A
A

7
6,5
-

9
8,5
-

9
8,5
-

17,5
17
-

21
20
-

21
20
-

33
31
-

42
40
-

42
40
-

220-230V
240V
380-400V

kW
kW
kW

3
3
4

4
4
5,5

5
5
7,5

6
7
11

6
7
11

8,5
9
15

11
11,5
18,5

12,5
13,5
22

18,5
19
30

22
23
37

415V
440V
500V

kW
kW
kW

4,5
4,5
5,5

6
6
7,5

8,5
8,5
10

12
12
10

12
12
15

16
16
18,5

20
20
18,5

24
24
30

33
33
37

40
40
45

660-690V
1000V

kW
kW

5,5
-

7,5
-

10
-

10
-

15
-

18,5
-

18,5
-

30
-

37
-

45
-

9
8,5

1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.

44

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type

K3-90

K3-115

K3-151

K3-176

K3-210

K3-260

K3-316

K3-450

K3-550

K3-700

K3-860

K3-1000 K3-1200

V~

1000

1000

1000

1000

1000

1000

1000

1000

1000

690

690

690

690

1100

1200

1500

2000

2100

2600

3200

4500

5500

7000

8600

10000

12000

A
A
A
A

950
850
600
-

1100
1000
600
-

1200
1200
1000
500

1500
1500
800
600

1600
1600
1200
700

2100
2100
1900
850

2600
2600
2300
1000

4500
4500
3200
-

5500
5500
4400
-

7000
7000
5600
-

8000
8000
6900
-

8000
8000
7000
-

10000
10000
8000
-

160

200

230

250

350

450

500

700

760

1000

1100

1200

1350

kW
kW
kW

60
63
66

76
79
83

87
91
95

95
99
103

133
139
145

171
179
187

190
199
207

266
279
291

289
302
315

381
398
415

419
438
457

457
478
498

514
537
561

kW
kW
kW

105
110
115

131
138
143

151
159
165

164
173
179

230
242
251

296
311
323

329
346
359

460
485
503

500
526
546

658
692
718

724
762
790

789
831
862

888
935
970

kW
kW
kW

121
138
182

152
173
228

175
199
262

190
216
285

266
303
400

342
389
514

381
453
571

533
606
800

579
658
868

762
866
1143

838
952
1257

914
1039
1371

1028
1169
1543

kW
kW

191
221

239
277

274
318

298
346

418
433

537
546

597
606

836
692

908
866

1195
-

1314
-

1434
-

1613
-

145

170

180

200

280

360

400

550

600

800

875

960

1080

kW
kW
kW

55
57
59

64
67
70

68
71
74

76
79
83

106
111
116

137
143
150

152
159
166

209
219
228

228
239
249

304
318
332

333
348
363

365
382
399

411
430
448

kW
kW
kW

95
100
104

111
117
122

118
124
129

131
138
143

184
193
201

237
249
259

263
277
287

362
381
395

395
415
431

526
554
575

575
606
628

631
665
690

710
748
776

kW
kW
kW

110
125
165

129
147
194

137
155
205

152
173
228

213
242
320

274
312
412

304
346
457

419
476
628

457
519
685

609
692
914

666
757
1000

731
831
1097

823
935
1234

kW
kW

173
166

202
187

215
277

239
346

334
388

430
499

478
554

657
692

717
866

956
-

1045
-

1147
-

1290
-

mm

95

120

95

120

240

2x150

A
A
A

90
90
90

115
115
115

150
150
150

175
175
175

210
210
210

260
260
260

315
315
315

450
450
450

550
550
550

700
700
700

860
860
860

1000
1000
1000

1200
1200
1200

A
A
A

90
90
90

115
115
115

150
150
150

175
175
175

210
210
210

260
260
260

315
315
315

450
450
450

550
550
550

700
700
700

860
860
860

1000
1000
1000

1200
1200
1200

A
A
A

60
58
58

60
58
58

150
120
60

175
140
70

210
150
85

260
180
100

315
240
125

450
400
200

550
500
250

700
630
-

860
700
-

1000
860
-

1200
1000
-

kW
kW
kW

25
27
45

33
35
55

40
45
75

50
55
90

60
65
110

75
80
132

90
100
160

132
140
250

175
185
300

225
235
400

280
290
500

325
335
580

390
400
680

kW
kW
kW

49
49
55

63
63
55

80
85
90

95
100
100

115
125
132

140
150
160

180
190
210

257
270
300

315
335
375

415
450
500

515
530
600

600
630
720

710
750
850

kW
kW

55
55

55
55

110
75

132
90

160
110

210
132

250
160

375
280

500
355

630
-

700
-

850
-

1000
-

D677E

2x(30x6) 2x(40x5) 2x(50x5) 2x(60x5) 2x(60x6) 2x(60x6) 2x(60x8)

45

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

Type K(G)3-10 K(G)3-14 K(G)3-18 K(G)3-22 K(G)3-24 K(G)3-32 K(G)3-40 K3-50

Utilization category AC4


Switching of squirrel cage motors, inching
Rated operational current Ie
220V A
open and enclosed
230V A
240V A

Rated operational power


of three-phase motors
50-60Hz

K3-62

K3-74

12
11,5
11

15
14,5
14

18
18
18

18
18
18

24
24
24

30
30
32

40
40
40

50
50
50

63
62
62

63
62
62

10
9
9

14
14
14

18
18
18

18
18
18

24
23
23

32
30
30

40
37
37

50
45
45

62
60
55

62
60
55

12
9
8,5
-

16
9
8,5
-

16
9
8,5

17,5
17
17
-

21
20
20
-

21
20
20
-

33
31
31
-

42
40
40
-

42
40
40
-

380-400V
415V
440V

A
A
A

500V
660V
690V
1000V

A
A
A
A

9
7
6,5
-

220-230V
240V
380-400V

kW
kW
kW

3
3
4

4
4
5,5

5
5
7,5

5
5
7,5

6
7
11

8,5
9
15

11
11,5
18,5

12,5
13,5
22

18,5
19
30

18,5
19
30

415V
440V
500V

kW
kW
kW

4,5
4,5
5,5

6
6
7,5

8,5
8,5
10

8,5
8,5
10

12
12
15

16
16
18,5

20
20
18,5

24
24
30

33
33
37

33
33
37

660-690V
1000V

kW
kW

5,5
-

7,5
-

10
-

10
-

15
-

18,5
-

18,5
-

30
-

37
-

37
-

Utilization category AC5a


Switching of gas discharge lamps
Rated operational current Ie
per pole at 220/230V
Fluorescent lamps,
uncompensated and serial compensated
parallel compensated
dual-connection

A
A
A

20
7
22,5

20
9
22,5

25
9
28

25
9
28

40
18
45

52
22
58

64
22
72

88
30
98

96
40
108

104
45
117

Metal halide lamps1),


uncompensated
parallel compensated

A
A

12
7

15
9

19
9

19
9

30
18

39
22

48
22

66
30

72
40

78
45

Mercury-vapour lamps2),
uncompensated
parallel compensated

A
A

22,5
7

25
9

28
9

28
9

45
18

58
22

72
22

99
30

108
40

117
45

Mixed light lamps3)

20

20

25

25

40

52

64

88

96

104

Utilization category AC5b


Switching of incandescent lamps4)
Rated operational current Ie
per pole at 220/230V

12,5

12,5

12,5

12,5

25

31

31

43

56

56

1) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps)
2) High-pressure lamps
3) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps)
4) Current inrush approx. 16 x Ie

46

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
K3-90

K3-115

K3-151

K3-176

K3-210

A
A
A

85
85
85

98
98
98

55
55
55

63
63
63

85
85
85

100
100
100

120
120
120

150
150
150

180
180
180

230
230
230

280
280
280

340
340
340

400
400
400

A
A
A

85
85
85

85
85
85

55
55
55

63
63
63

85
85
85

100
100
100

120
120
120

150
150
150

180
180
180

230
230
230

280
280
280

340
340
340

400
400
400

A
A
A
A

85
60
57,5
-

85
60
57,5
-

kW
kW
kW

25
27
45

30
32
45

15
15,5
25

18,5
19
30

25
26
45

30
31
55

37
38
63

45
47
75

51
53
90

68
71
120

80
83
150

110
115
185

132
137
220

kW
kW
kW

49
49
55

49
49
55

25
30
25

33
34
30

45
48
55

55
55
65

65
67
75

80
85
100

100
100
110

132
132
150

160
160
185

200
200
220

230
230
257

kW
kW

55
-

55
-

25
-

30
-

55
-

65
-

75
-

100
-

110
-

150
-

185
-

220
-

257
-

A
A
A

100
55
112

120
70
144

120
85
120

140
100
140

180
130
180

220
160
220

280
200
280

360
300
360

450
360
450

570
460
570

700
550
700

850
660
850

1000
800
1000

A
A

85
55

90
70

95
75

110
85

140
110

180
140

230
170

300
260

380
300

490
400

610
480

750
580

890
700

A
A

112
55

144
70

120
75

140
85

180
110

220
140

280
170

360
260

450
300

570
400

700
480

850
580

1000
700

100

120

100

120

160

200

250

320

400

500

600

700

800

69

75

100

120

160

190

220

260

315

440

500

560

630

Type

D677E

K3-260

K3-316

K3-450

K3-550

K3-700

K3-860

K3-1000 K3-1200

47

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

Type K(G)3-10 K(G)3-14 K(G)3-18 K(G)3-22 K(G)3-24 K(G)3-32 K(G)3-40 K3-50

Utilization category AC6a


Transformer primary switching
at inrush
Rated operational current Ie

400V

n
A

30
4,5

30
5,5

30
7,5

30
7,5

30
10,5

30
13,5

30
13,5

K3-62

K3-74

30
20

30
27

30
33

8
8,3
13,5

10,7
11,2
18,5

13
13,5
22,5

Rated operational power


dependent on inrush n

220-230V
240V
380-400V

kVA
kVA
kVA

1,8
1,9
3,1

2,2
2,3
3,8

3
3,1
5,2

3
3,1
5,2

4,2
4,3
7,3

5,4
5,6
9,3

5,4
5,6
9,3

For different inrush-factors x


use the following formula:
Px=Pn*(n/x)

415-440V
500V
660-690V

kVA
kVA
kVA

3,4
3,9
5,4

4,2
4,8
6,5

5,7
6,5
9

5,7
6,5
9

8
9
12,5

10,2
11,5
16

10,2
11,5
16

15
17
24

20,5
23
32

25
28
39

20
15,5

20
15,5

25
23

25
32

25
32

25
45

25
60

20
70

6
6,5
10

6
6,5
10

8,5
9,5
15

12
13
20

12
13
20

17
18,5
29

24
25
39

28
29
46

Utilization category AC6b


Switching of three-phase capacitors
Maximum inrush current (peak value)
as multiple k of the
capacitor rated current
Rated operational current Ie
500V

k
A

35
8

25
12

Rated operational power


(sin1)

220-230V
240V
380-400V

kVAr
kVAr
kVAr

3
3,5
5

For different multiples x


use the following formula:
Px=Pk*(k/x)

415-440V
500V
660-690V

kVAr
kVAr
kVAr

5,5
7
7

8
10
10

11
13
13

11
13
13

16
20
20

22
26
26

22
26
26

32
39
40

43
50
50

50
58
58

13

18

20

28

36

42

48

72

108 1)

220-230V
240V
380-400V

kVAr
kVAr
kVAr

2,9
3,1
5

5
5,4
9

7
7
12,5

7,5
8
13

11
11
20

14
14
25

16
17
27,5

20
20
33,3

28
28
50

33
36
75 1)

415-440V
500V
660-690V
1000V

kVAr
kVAr
kVAr
kVAr

5,5
6
8
-

9,5
11
15
-

13
15
20
-

14
17
22
-

22
25
33
-

27
30
41
-

30
36
48
-

36
40
55
-

53
60
82
-

75 1)
75
100
-

Switching of
reactive capacitor banks
Rated operational current Ie
Rated operational power

Utilization category DC1


Switching of resistive load
Time constant L/R 1ms
Rated operational current Ie

690V

4,5
5
7,5

1 pole 24V
60V
110V
220V

A
A
A
A

20
20
6
0,8

25
25
6
0,8

32
32
6
0,8

32
32
6
0,8

50
50
10
1,4

65
65
10
1,4

80
80
10
1,4

110
110
12
1,4

120
120
12
1,4

130
130
12
1,4

3 poles in series 24V


60V
110V
220V

A
A
A
A

20
20
20
16

25
25
25
20

32
32
32
20

32
32
32
20

50
50
50
30

65
65
65
35

80
80
80
35

110
110
110
63

120
120
120
80

130
130
130
80

Utilization category DC3 and DC5


Switching of shunt motors
and series motors
Time constant L/R 15ms
Rated operational current Ie 1 pole 24V
60V
110V
220V

A
A
A
A

20
6
1,2
0,2

25
6
1,2
0,2

32
6
1,2
0,2

32
6
1,2
0,2

50
30
1,8
0,2

65
30
1,8
0,2

80
30
1,8
0,2

110
60
1,8
0,25

120
60
1,8
0,25

130
60
1,8
0,25

3 poles in series 24V


60V
110V
220V

A
A
A
A

20
20
20
2,5

25
25
20
2,5

32
32
20
2,5

32
32
20
2,5

50
40
40
4

65
40
40
4

80
40
40
4

110
80
80
5

120
80
80
5

130
80
80
5

1) Consider resistive load (Ith). see page 44

48

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
K3-90

K3-115

K3-151

K3-176

K3-210

n
A

30
38

30
50

30
65

30
80

30
90

30
120

30
142

30
203

30
248

30
315

30
390

30
450

30
540

kVA
kVA
kVA

15
15,5
26

20
20,5
34

25
27
45

30
33
55

34
37
60

45
50
80

54
59
95

77
80
140

95
100
170

120
130
210

148
160
270

170
185
310

200
220
370

kVA
kVA
kVA

29
33
45

38
43
60

46
55
56

57
69
69

63
75
100

85
100
135

100
120
160

145
170
200

175
210
250

220
270
320

280
330
350

320
380
500

380
460
600

k
A

20
87

20
100

20
120

20
155

25
195

20
225

20
255

20
300

20
370

20
440

20
520

20
680

20
760

kVAr
kVAr
kVAr

33
36
57

38
42
65

45
52
80

60
62
100

75
78
130

90
94
155

100
104
170

115
120
200

145
150
250

170
175
300

200
205
350

260
270
450

290
300
500

kVAr
kVAr
kVAr

60
70
70

70
80
80

95
100
100

110
130
130

135
170
170

165
194
194

175
220
220

210
260
260

260
320
320

310
380
380

360
450
450

465
590
590

520
660
660

115

144

115

140

200

225

250

330

420

550

600

680

760

kVAr
kVAr
kVAr

45
45
80

55
55
100

43
45
75

53
55
90

76
80
130

85
90
145

95
100
160

125
130
210

160
170
270

209
220
350

228
240
390

260
280
440

290
310
480

kVAr
kVAr
kVAr
kVAr

100
105
120
160

120
125
148
200

80
95
125
155

100
120
150
200

140
170
200
300

160
190
230
340

170
210
260
400

230
280
350
500

290
350
450
650

380
450
600
-

420
500
650
-

470
570
700
-

530
640
800
-

A
A
A
A

160
160
20
2

200
200
25
2,5

A
A
A
A

160
160
160
100

200
200
200
160

200
200
150
80

250
250
170
100

350
350
250
150

400
400
280
180

450
450
315
200

600
600
400
250

760
760
480
315

1000
1000
560
400

1100
1100
630
450

1200
1200
800
500

1350
1350
900
600

A
A
A
A

160
85
2
0,5

200
110
2,5
0,5

A
A
A
A

160
100
100
7

200
110
110
8

Type

D677E

K3-260

K3-316

K3-450

K3-550

K3-700

K3-860

K3-1000 K3-1200

49

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

Type K(G)3-10 K(G)3-14 K(G)3-18 K(G)3-22 K(G)3-24 K(G)3-32 K(G)3-40 K3-50

Maximum ambient temperature


Operation
with thermal overload relay
enclosed
Storage

open
enclosed
open

C
C
C
C
C

K3-62

K3-74

-40 to +60 (+90) 1)


-40 to +40
-25 to +60
-25 to +40
-50 to +90

Short circuit protection


for contactors without thermal overload relay
Coordination-type "1" according to IEC 947-4-1
Contact welding without
hazard of persons
max. fuse size
gL (gG) A

63

63

63

63

80

80

80

160

160

160

Coordination-type 2 according to IEC 947-4-1


Light contact welding accepted
max. fuse size
gL (gG) A

25

35

35

35

50

50

50

100

125

125

16

16

16

16

25

35

35

50

63

63

Contact welding not accepted


max. fuse size
gL (gG) A
For contactors with thermal overload relay the
device with the smaller admissible backup fuse
(contactor or thermal overload relay)
determines the fuse size.
Cable cross-sections
for contactors without thermal overload relay
1 cable per clamp
main connector
solid or stranded mm
flexible mm
flexible with multicore cable end mm
2 cables per clamp

4 - 50
10 - 35
6 - 35

6+(1-6) / 4+(0,75-4)
2,5+(0,75-2,5) / 1,5+(0,75-1,5)
6+(1,5-4) / 4+(1-4)
2,5+(0,75-2,5) / 1,5+(0,75-1,5)

16+(2,5-16) / 10+(4-16)
6+(4-16) / 4+(2,5-16)
16+(2,5-6) / 10+(4-10)
6+(4-16) / 4+(2,5-16)

50+4 / 35+6 / 25+(6-16)


16+(6-16) / 10+(6-16)
50+(4-10) / 35+(4-16)
25+(4-25) / 16+(4-16)

mm

flexible

mm

solid
flexible

AWG
AWG

18 - 10
18 - 10

16 - 10
14 - 4

12 - 10
10 - 0

solid

AWG
AWG

10+(16-10) / 12+(18-12)
14+(18-14) / 16+(18-16)
4+(18-12) / 6+(18-8)
8+(18-8) / 10+(18-12)

10+(12-10) / 12+12

flexible

10+(16-10) / 12+(18-12)
14+(18-14) / 16+(18-16)
10+(14-10) / 12+(18-12)
14+(18-14) / 16+(18-16)

1+(12-10) / 2+(8-12)
3+(12-8) / 4+(10-6)

10000
600
120
600

7000
600
120
600

7000
400
120
400

10
10
50

10
10
50

10
10
-

2 cables per clamp

Frequency of operations z
Contactors without thermal overload relay
without load
AC3, Ie
AC4, Ie
DC3, Ie
Mechanical life
AC operated
DC operated
DC-solenoid operated (KG3)

Power loss per pole


contact resistance

1,5 - 25
2,5 - 16
1,5 - 16

solid or stranded

1 cable per clamp


main connector

Short time current

0,75 - 6
1-4
0,75 - 4

1/h
1/h
1/h
1/h

S x 106
S x 106
S x 106
10s-current
120s-current

at Ie/AC3 400V

Resistance to shock acc. to IEC 68-2-27


Shock time 20ms sine-wave
NO
NC

A
A
W
mOhm
g
g

96
28

120
35

144
42

176
51

184
53

240
69

296
85

360
104

504
145

592
171

0,21
2,1

0,35
1,8

0,5
1,5

0,75
1,5

0,7
1,2

1,3
1,2

2
1,2

2,2
1

3,9
1

5,5
1

10
6

10
6

10
6

10
6

8
-

8
-

8
-

8
-

8
-

8
-

1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3

50

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type

K3-90

K3-115

C
C
C
C
C

-40 to +60 (+90) 1)


-40 to +40
-25 to +60
-25 to +40
-50 to +90

K3-151

K3-176

K3-210

K3-260

K3-316

K3-450

K3-550

K3-700

K3-860

K3-1000 K3-1200

-25 to +55 (+70) 2)


-25 to +40
-25 to +55
-25 to +40
-55 to +80

250

250

250

315

400

450

500

630

630

800

1000

1000

1250

160

200

200

250

315

400

400

500

560

100

125

160

200

250

315

busbar
18 x 4
screw
M8

busbar
25 x 6
screw
M10

busbar
30 x 5
screw
M12

busbar
40 x 6
screw
M12

busbar
50 x 8
screw
M12

busbar
50 x 8
screw
M14

3000
300
120
300

1200
-

1200
-

1200
-

300
-

5
5
-

10
10
-

5
5
-

5
5
-

5 3)
5 3)
-

mm
mm
mm

0,5 - 95
0,5 - 70
0,5 - 70

10 - 120
25 - 95
10 - 95

mm
mm
mm

0,5 - 95 + 10 - 120

AWG
AWG

18 - 10
18 - 3/0

busbar
50 x 10
screw
2 x M12

0,5 - 70 + 25 - 95

8 - 4/0

AWG

AWG

18 - 3/0 + 8 - 4/0

1/h
1/h
1/h
1/h
S x 106
S x 106
S x 106
A
A

680
196

880
254

1200
346

1400
404

1800
520

2200
751

2600
900

3600
1039

4400
1270

5600
1617

6900
1992

8000
2309

9600
2771

4,8
0,6

7,9
0,5

9
0,4

11
0,35

8
0,18

11
0,16

14,9
0,15

26,3

33,3

49

59,2

60

72

7
5

7
5

mOhm

g
g

1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
2) With reduced control voltage range 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
3) After each 1x106 operations magnetic core and built-in auxiliary contact block must be changed

D677E

51

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Auxiliary Contacts
Rated insulation voltage Ui

Type K(G)3-10 K(G)3-14 K(G)3-18 K(G)3-22 K(G)3-24 K(G)3-32 K(G)3-40 K3-50


V~

690

40C
60C

A
A

16
12

220-240V
380-415V
440V

A
A
A

12
4
4

500V
660-690V

A
A

3
1

60V
110V
220V

A
A
A

8
1
0,1

1)

Thermal rated current Ith to 690V


Ambient temperature
Utilization category AC15
Rated operational current Ie

Utilization category DC13


Rated operational current Ie

Short circuit protection


short-circuit current 1kA,
contact welding not accepted
max. fuse size

K3-62

For contactors with thermal overload relay the device with the smaller admissible control
fuse (contactor or thermal overload relay) determines the fuse.
gL (gG)

25

inrush
sealed

VA
VA
W

33-45
7-10
2,6-3

90-115
9-13
2,7-4

140-165
13-18
5,4-7

DC operated
double winding coil

inrush
sealed

W
W

75
2

140
2

200
6

DC solenoid operated
(KG3)

inrush
sealed

W
W

3
3

4
4

0,85-1,1
0,8-1,1

0,85-1,1
0,8-1,1

0,85-1,1
0,8-1,1

8-16
5-13
10-15

10-25
8-15
10-15

12-28
8-15
10-15

Control Circuit
Power consumption of coils
AC operated

Operation range of coils


in multiples of control voltage Us
AC operated
DC operated
Switching time at control voltage Us 10% 2) 3)
AC operated
make time ms
release time ms
arc duration ms
DC operated
double winding coil

make time
release time
arc duration

ms
ms
ms

8-12
8-13
10-15

10-20
10-15
10-15

12-23
10-18
10-15

DC solenoid operated
(KG3)

make time
release time
arc duration

ms
ms
ms

65 - 85
20 - 30 4)
10-15

65 - 85
20 - 30 4)
10-15

mm
mm
mm

0,75-6
1-4
0,75-4

solid
flexible
flexible with multicore cable end
Clamps per pole

mm
mm
mm

0,75-2,5
0,5-2,5
0,5-1,5
2

0,75-2,5
0,5-2,5
0,5-1,5
2

0,75-2,5
0,5-2,5
0,5-1,5
2

Auxiliary connector

solid
flexible

AWG
AWG

18 - 10
18 - 10

Magnet coil

solid
flexible

AWG
AWG

14 - 12
18 - 12
2

14 - 12
18 - 12
2

14 - 12
18 - 12
2

Cable cross-section
Auxiliary connector

solid
flexible
flexible with multicore cable end

Magnet coil

Clamps per pole

K3-74

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request
2) Total breaking time = release time + arc duration
3) Values for delay of the release time of the make contact and the make time of the break contact will be increased, if magnet coils are protected against voltage
peaks (varistor, RC-unit, diode-unit)
4) with built-in coil suppressor

52

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type

K3-90

K3-115

K3-151

K3-176

K3-210

K3-260

K3-316

K3-450

K3-550

K3-700

K3-860

K3-1000 K3-1200

V~

690

690

690

A
A
-

10
-

10
-

10
-

A
A
A

3
2
1,5

3
2
1,5

3
2
1,5

A
A

1,5
1

1,5
1

1,5
1

A
A
A

1
0,5

1
0,5

1
0,5

10

10

10

VA
VA
W

165-220
2,5-5
2,5-5

350
5
5

360
5
5

800-950
9-11
9-11

1350-1600
21-25
21-25

2400
70
70

W
W

250
5

350
5

360
5

700-850
8-10

1300-1550
18-22

2100
60

W
W

0,85-1,1
0,8-1,1

0,85-1,1
0,85-1,1

0,85-1,1
0,85-1,1

0,85-1,1
0,85-1,1

0,85-1,1
0,85-1,1

ms
ms
ms

20-35
60-70
10-15

30-60
30-80

40-60
15-45
-

50-100
150-200 / 500-10001)
-

50-100
25-50
-

ms
ms
ms

20-35
60-70
10-15

30-60
30-80
-

40-60
15-45
-

ms
ms
ms

mm
mm
mm

0,75-2,5
0,75-2,5
-

0,75-2,5
0,75-2,5
-

mm
mm
mm

0,75-2,5
0,5-2,5
0,5-1,5
2

1-2,5
1-2,5
2

1-2,5
1-2,5
2

1-2,5
1-2,5
2

1-2,5
1-2,5
2

AWG
AWG

16 - 12
16 - 12

16 - 12
16 - 12

AWG
AWG

14 - 12
18 - 12
2

16 - 12
16 - 12
2

16 - 12
16 - 12
2

16 - 12
16 - 12
2

16 - 12
16 - 12
2

1) Normal or delayed drop is adjustable

D677E

53

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

K2-09

K2-12

K2-16

K2-23

K2-30

K2-37

K2-45

K2-60

K85

K110

V~

690

690

690

690

690

690

690

690

750

750

at Ue = 690V AC

200

200

200

400

500

500

700

900

1100

1200

Breaking capacity Ieff


400V~
K2-09 to K2-16
cos = 0,65 500V AC
K2-23 to K3-1200 cos = 0,35 690V AC
1000V~

A
A
A
A

180
150
100
-

180
150
100
-

200
180
150
-

380
300
260
-

400
370
340
-

400
370
340
-

600
500
400
-

800
700
500
-

950
850
600
-

1100
1100
600
-

25

25

25

45

50

50

80

100

150

170

220V
230V
240V

kW
kW
kW

9,5
10
10,5

9,5
10
10,5

9,5
10
10,5

17
18
18,5

19
20
20,5

19
20
20,5

30
31,5
33

38
40
41

57
59
62

64
67
70

380V
400V
415V

kW
kW
kW

16,5
17,5
18

16,5
17,5
18

16,5
17,5
18

29,5
31
32

33
34,5
36

33
34,5
36

52
55
57

65
69
71

98
103
107

111
117
122

440V
500V
660V

kW
kW
kW

19
21,5
28,5

19
21,5
28,5

19
21,5
28,5

34
39
51

38
43
57

38
43
57

61
69
91

76
86
114

114
130
171

129
147
194

690V

kW

29,5

29,5

29,5

53,5

60

60

95

119

179

203

20

25

25

35

40

40

63

80

100

125

Type

Rated insulation voltage Ui


Making capacity Ieff

1)

Utilization category AC1


Switching of resistive load
Rated operational current Ie (=Ith)
at 40C, open
Rated operational power
of three-phase resistive loads
50-60Hz, cos = 1

Rated operational current Ie (=Ithe)


at 60C, enclosed
Rated operational power
of three-phase resistive loads
50-60Hz, cos = 1

Minimum cross-section of conductor


at load with Ie (=Ith)
Utilization category AC2 and AC3
Switching of three-phase motors
Rated operational current Ie
open and enclosed

Rated operational power


of three-phase motors
50-60Hz

220V
230V
240V

kW
kW
kW

7,5
8
8

9,5
10
10,5

9,5
10
10,5

13
13,5
14,5

15
16
16,5

15
16
16,5

24
25
26

30
31,5
33

38
40
41

47
49
52

380V
400V
415V

kW
kW
kW

13
13,5
14

16,5
17,5
18

16,5
17,5
18

23
24
25

26
27,5
28,5

26
27,5
28,5

41
43
45

52
55
57

65
69
71

82
86
89

440V
500V
660V

kW
kW
kW

15
17
22,5

19
21,5
28,5

19
21,5
28,5

26,5
30
40

30
34
45

30
34
45

48
54
72

61
69
91

71
86
114

95
116
142

690V

kW

23,5

29,5

29,5

42

48

48

75

95

119

149

10

10

10

25

35

50

70

mm

220V
230V
240V

A
A
A

12
11,5
11

15
14,5
14

18
17,5
17

23
23
23

30
30
30

37
37
37

45
45
45

63
61
60

85
85
85

110
110
110

380-400V
415-440V
500V

A
A
A

10
9
9

12
12
12

16
16
16

23
23
23

30
30
30

37
37
30

45
45
45

60
60
55

85
85
85

110
110
110

660V
690V

A
A

7
6,5

9
8,5

9
8,5

17,5
17

21
20

21
20

33
31

42
40

60
58

60
58

220-230V
240V
380-400V

kW
kW
kW

3
3
4

4
4
5,5

5
5
7,5

6
7
11

8,5
9
15

11
11,5
18,5

12,5
13,5
22

18,5
19
30

25
27
45

33
35
55

415V
440V
500V

kW
kW
kW

4,5
4,5
5,5

6
6
7,5

8,5
8,5
10

12
12
15

16
16
18,5

20
20
18,5

24
24
30

33
33
37

49
49
55

63
63
55

660-690V

kW

5,5

7,5

7,5

15

18,5

18,5

30

37

55

55

1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
Data for other conditions on request.

54

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

Type

Utilization category AC4


Switching of squirrel cage motors, inching
Rated operational current Ie
220V A
open and enclosed
230V A
240V A

Rated operational power


of three-phase motors
50-60Hz

K2-09

K2-12

K2-16

K2-23

K2-30

K2-37

K2-45

K2-60

K85

K110

12
11,5
11

15
14,5
14

16
16
16

23
23
23

30
30
30

37
37
37

45
45
45

63
61
60

85
85
85

98
98
98

10
9
9

12
12
12

16
16
16

23
21
21

30
28
28

37
37
37

45
45
45

60
60
60

85
85
85

85
85
85

12
9
8,5

16
9
8,5

17
13
12,5

23
17
16,5

23
17
16,5

45
33
31

55
42
40

85
60
57,5

85
60
57,5

380-400V
415V
440V

A
A
A

500V
660V
690V

A
A
A

9
7
6,5

220-230V
240V
380-400V

kW
kW
kW

3
3
4

4
4
5,5

5
5
7,5

6
7
11

8,5
9
15

11
11,5
18,5

12,5
13,5
22

18,5
19
30

25
27
45

30
32
45

415-440V
500V
660-690V

kW
kW
kW

4,5
5,5
5,5

6
7,5
7,5

8,5
10
7,5

11
11
11

15
15
15

20
15
15

24
30
30

33
37
37

49
55
55

49
55
55

Utilization category AC5a


Switching of gas discharge lamps
Rated operational current Ie
per pole at 220/230V
Fluorescent lamps, uncompensated
Fluorescent lamps, compensated
Fluorescent lamps, dual-connection

A
A
A

20
7
22,5

20
9
22,5

20
9
22,5

35
18
41

40
22
45

40
22
45

65
30
72

85
40
90

100
55
112

120
70
144

Metal-halide lamps1), uncompensated


Metal-halide lamps1), compensated

A
A

12
7

15
9

15
9

28
18

30
22

30
22

50
30

62
40

85
55

90
70

Mercury-vapour lamps2), uncompensated


Mercury-vapour lamps2), compensated

A
A

22,5
7

25
9

25
9

41
18

45
22

45
22

72
30

90
40

112
55

144
70

Mixed light lamps3)

20

20

20

35

40

40

65

85

100

120

Utilization category AC5b


Switching of incandescent lamps 4)
Rated operational current Ie
per pole at 220/230V

12,5

12,5

12,5

25

31

31

43

56

69

75

n
A

30
4,5

30
5,5

30
7,5

30
10,5

30
13,5

30
13,5

30
20

30
27

30
38

30
50

8
8,3
13,5

10,7
11,2
18,5

15
15,5
26

20
20,5
34

20,5
23
32

29
33
45

38
43
60

Utilization category AC6a


Transformer primary switching
at inrush
Rated operational current Ie

400V

Rated operational power


dependent on inrush n

220-230V
240V
380-400V

kVA
kVA
kVA

1,8
1,9
3,1

2,2
2,3
3,8

3
3,1
5,2

4,2
4,3
7,3

5,4
5,6
9,3

5,4
5,6
9,3

For different inrush-factors x


use the following formula:
Px=Pn*(n/x)

415-440V
500V
660-690V

kVA
kVA
kVA

3,4
3,9
5,4

4,2
4,8
6,5

5,7
6,5
9

8
9
12,5

10,2
11,5
16

10,2
11,5
16

15
17
24

Utilization category DC1


Switching of resistive load
Time constant L/R 1ms
Rated operational current Ie

1 pole 24V
60V
110V
220V

A
A
A
A

20
20
6
0,8

25
25
6
0,8

25
25
6
0,8

45
45
10
1,4

50
50
10
1,4

50
50
10
1,4

80
80
12
1,4

100
100
12
1,4

150
150
20
2

170
170
25
2,5

3 poles in series 24V


60V
110V
220V

A
A
A
A

20
20
20
16

25
25
25
20

25
25
25
20

45
45
45
30

50
50
50
35

50
50
50
35

80
80
80
63

100
100
100
80

150
150
150
100

170
170
170
160

1) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps)
2) High-pressure lamps
3) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps)
4) Current inrush approx. 16 x Ie
5) With central compensation pay attention to the current inrush (capacitor switching contactors)

D677E

55

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Main Contacts

Type

Utilization category DC3 and DC5


Switching of shunt motors
and series motors
Time constant L/R 15ms
Rated operational current Ie 1 pole 24V
60V
110V
220V

A
A
A
A

20
6
1,2
0,2

25
6
1,2
0,2

25
6
1,2
0,2

45
30
1,8
0,2

50
30
1,8
0,2

50
30
1,8
0,2

80
60
1,8
0,25

100
60
1,8
0,25

150
85
2
0,5

170
110
2,5
0,5

3 poles in series 24V


60V
110V
220V

A
A
A
A

20
20
20
2,5

25
25
20
2,5

25
25
20
2,5

45
40
40
4

50
40
40
4

50
40
40
4

80
80
80
5

100
80
80
5

150
100
100
7

170
110
110
8

Maximum ambient temperature


Operation
with thermal overload relay
enclosed

open
enclosed
open

Storage

K2-09

K2-12

K2-16

K2-23

K2-30

K2-37

C
C
C
C

-40 to +60 (+90) 1)


-40 to +40
-25 to +60
-25 to +40

-50 to +90

K2-45

K2-60

K85

K110

Short circuit protection


for contactors without thermal overload relay
Coordination-type "1" according to IEC 947-4-1
Contact welding without
hazard of persons
max. fuse size
gL (gG) A

63

63

63

80

80

80

160

160

250

250

Coordination-type 2 according to IEC 947-4-1


Light contact welding accepted
max. fuse size
gL (gG) A

25

35

35

50

50

50

100

125

160

200

16

16

16

25

35

35

50

63

100

125

Contact welding not accepted


max. fuse size
gL (gG) A
For contactors with thermal overload relay the
device with the smaller admissible backup fuse
(contactor or thermal overload relay)
determines the fuse size.
Cable cross-sections
for contactors without thermal overload relay
main connector
solid or stranded mm
flexible mm
flexible with multicore cable end mm
Cables per clamp
main connector
Cables per clamp

0,75 - 4
0,75 - 2,5
0,5 - 2,5
2

1,5-10 + 1,5-6
1,5-6 + 1,5-4
1,5-6 + 1,5-4
1+1

4 - 35 2)
6 - 25 2)
4 - 25
1

10 - 70 2)
10 - 70 2)
10 - 35
1

AWG
AWG

14 - 10
18 - 10
2

14 - 10 + 14 - 10
14 - 8 + 14 - 10
1+1

10
10 - 2
1

10
6-0
1

1/h
1/h
1/h
1/h

10000
600
120
600

7000
600
120
600

7000
400
120
400

3000
300
120
300

S x 106
S x 106

10
10

10
10

10
10

5
5

solid
flexible

Frequency of operations z
Contactors without thermal overload relay
without load
AC3, Ie
AC4, Ie
DC3, Ie
Mechanical life
AC operated
DC operated with economy resistor
Short time current

10s-current

at Ie/AC3 400V

Resistance to shock acc. to IEC 68-2-27


Shock time 20ms sine-wave
NO
NC

g
g

Power loss per pole

96
0,21
10
6

120
0,26
10
6

144
0,4
10
6

184

240

296

360

504

880

0,63

1,1

1,7

1,8

3,6

4,3

6,0

8
5

8
5

8
5

8
-

8
-

7
5

7
5

1) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie /AC1according to Ie /AC3
2) Maximum cable cross-section with prepared conductor

56

680

D677E

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Auxiliary Contacts

Type

Rated insulation voltage Ui

K2-16

K2-23

K2-30

K2-37

K2-45

K2-60

K85

K110

690

690

690

40C
60C

A
A

16
12

16
12

16
12

220-240V
380-415V
440V

A
A
A

12
4
4

12
4
4

12
6
6

500V
660-690V

A
A

3
1

3
1

4
2

60V
110V
220V

A
A
A

8
1
0,1

8
1
0,1

8
1
0,1

25

25

280-350 350-420
16-23 23-29
4-6
6-7,3

Thermal rated current Ith to 690V


Ambient temperature

Utilization category DC13


Rated operational current Ie

K2-12

V AC

1)

Utilization category AC15


Rated operational current Ie

K2-09

Short circuit protection


short-circuit current 1kA,
contact welding not accepted
max. fuse size
gL (gG) A
For contactors with thermal overload relay the
device with the smaller admissible control fuse
(contactor or thermal overload relay)
determines the fuse.
Control Circuit
Power consumption of coils
AC operated

inrush
sealed

VA
VA
W

33-45
7-10
2,6-3

90-115
9-13
2,7-4

140-165
13-18
5,4-7

DC operated
with economic circuit

inrush
sealed

W
W

75
2

140
2

200
6

0,85-1,1
0,8-1,1

0,85-1,1
0,8-1,1

0,85-1,1
0,8-1,1

0,85-1,1
0,8-1,1

Operation range of coils


in multiples of control voltage Us
AC operated
DC operated

170
2

320
4

Switching time at control voltage Us 10% 2) 3)


AC operated

make time
release time
arc duration

ms
ms
ms

8-16
5-13
10-15

10-25
8-15
10-15

12-28
8-15
10-15

13-30
8-15
10-15

DC operated
with AC magnet system

make time
release time
arc duration

ms
ms
ms

8-12
8-13
10-15

10-20
10-15
10-15

12-23
10-18
10-15

20-30
10-18
10-15

Cable cross-section
Auxiliary connector

solid
flexible
flexible with multicore cable end

mm
mm
mm

0,75-4
0,75-2,5
0,5-2,5

0,75-2,5
0,75-2,5
0,5-1,5

Magnet coil

mm
mm
mm

0,75-2,5
0,5-2,5
0,5-1,5

0,75-2,5
0,5-2,5
0,5-1,5

0,75-2,5
0,5-2,5
0,5-1,5

0,75-2,5
0,5-2,5
0,5-1,5

solid
flexible
flexible with multicore cable end

Clamps per pole

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request
2) Total breaking time = release time + arc duration
3) Values for delay of the release time of the make contact and the make time of the break contact will be increased, if magnet coils are protected against voltage
peaks (varistor, RC-unit, diode-unit)

D677E

57

Contactors for North America


Data according to UL508
Main Contacts (cULus)

Type K(G)3-10 K(G)3-14 K(G)3-18 K(G)3-22 K(G)3-24 K(G)3-32 K(G)3-40 K3-50

Rated operational current


"General Use"

25

25

30

30

50

65

80

10

14

18

22

22

27

5
7
10
7

Motor DOL 3-phase at 60Hz


Rated operational current
Rated operational power

600V

120

130

34

44

52

66

5
10
10
10

7
10
15
15

10
15
20
20

10
20
25
25

10
25
30
30

1
3
3
3

2
3
3
5

380-415V
440-480V
550-600V

hp
hp
hp

5
5
7

5
7
10

10
10
15

10
15
20

10
15
20

15
20
25

20
25
30

25
30
40

30
40
50

40
50
50

18

22

22

27

34

44

52

66

3
7
7
10

3
7
10
10

5
10
15
15

7
15
15
15

10
15
20

15
20
25

20
25
30

20
25
30

27

37

5
10
10

10

14

110-120V
200V
220-240V
277V

hp
hp
hp
hp

1
1
2

1,5
2
3

380-415V
440-480V
550-600V

hp
hp
hp

3
3
3

3
5
5

5
5
7

Motor DOL 3-phase according to ANSI A17.5


Rated operational current
600V

Rated operational power


of 3-phase motors for elevators
(500.000 operations)

110-120V
200V
220-240V

hp
hp
hp

440-480V
550-600V

hp
hp

Rated operational power


of AC motors
at 60Hz (1ph)

110

hp
hp
hp
hp

600V

Rated current 2 series contacts

600V

1
2
3
3

3
5
7
7

K3-74

110-120V
200V
220-240V
277V

Motor DOL 1-phase at 60Hz


Rated operational current

2
5
7
7

K3-62

1
3
3
5

1
3
5
5

2
5
5
7

5
7
10

5
7
10

7
10
15

15

22

2
3
5

10
10

15
20

20
25

25
30

22

27

44

52

66

90/5

90/5

125/5

175/5

200/5

250/5

300/5

3
5
7

3
7
7

Fuse Class RK5 / Short-circuit current

A/kA

50/5

50/5

70/5

Fuse Class T / Short-circuit current


Rated voltage

A/kA
V

45/100
600

50/100
600

70/100
600

A600

A600

A600

A600

K2-09

K2-12

K2-16

K2-23

K2-30

K2-45

K2-60

K85

K110

25

25

25

40

40

72

90

125

150

5
7
10

10
15

15
20

15
35

30
40

20
25

30
40

40
50

65
85

75
100

5
7
10

8
20

10
20
20

Auxiliary Contacts (cULus)

Main Contacts (cULus)

Type

Rated operational current


"General Use"

Motor DOL 3-phase at 60Hz


Rated operational power

Motor DOL 1-phase at 60Hz


Rated operational power

110-120V
200V
220-240V

hp
hp
hp

1
2
3

2
3
3

2
3
5

440-480V
550-600V

hp
hp

5
7

7
10

10
15

110-120V
200V
220-240V

hp
hp
hp

1
1

2
2

1
2
3

90/100 110/100 150/100


600
600
600

3
5
7
15
20
1
3
3

2
3
5

3
5
7

150/100 175/100 175/100 175/100


600
600
600
600

Fuse / Short-circuit current

A/kA

30/5

40/5

50/5

60/5

110/5

175/5

175/5

300/5

Rated voltage

600

600

600

600

600

600

600

600

600

A600

A600

A600

A600

A600

A600

A600

Auxiliary Contacts (cULus)

58

D677E

Contactors for North America


Data according to UL508
K3-90

K3-115

K3-151

K3-176

K3-210

K3-260

K3-316

K3-450

K3-550

K3-700

K3-860

160

200

180

220

250

300

350

420

520

700

810

1215

85

99

125

150

190

240

300

300

400

550

700

1000

hp
hp
hp
hp

15
25
35
-

20
35
40
-

40
50
-

50
60
-

60
75
-

75
100
-

100
125
-

125
125
-

150
150
-

200
250
-

250
300
-

450
450
-

hp
hp
hp

50
65
85

60
75
100

100
125

125
150

150
200

200
250

250
300

250
250

350
350

500
500

600
600

900
900

86

103

125

150

hp
hp
hp
hp

8
15
20
20

10
20
25
25

15
25
-

25
30
-

40
-

50
-

50
-

hp
hp
hp

30
40
50

40
50
60

hp
hp
hp

hp
hp

300/10

300/10

300/10

350/10

400/18

500/18

500/18

1200/18

1200/18

2000/42

600

600

600

600

600

600

600

600

600

600

A600

A600

A600

A600

A600

Type

A/kA
A/kA
V

300/100 3) 300/100 3)
600
600
-

Main Contacts (cULus)

K3-1000 K3-1200

2000/30 2000/30

Type

K3-18NK

K3-24K

K3-32K

K3-50K

K3-62K

K3-74K

K3-90K

K3-115K

110-120V
200V
220-240V

kVAr
kVAr
kVAr

0-3,5
0-6
0-7

3-5,5
4,5-10
5,5-11

3-7
4,5-12,5
5,5-15

6,5-10
10-16,7
12,5-20

6,5-15
10-25
12,5-30

6,5-18 1)
10-32 1)
12,5-36 1)

10-24
17-40
20-47

10-28 2)
17-46 2)
20-56 2)

440-480V
550-600V

kVAr
kVAr

0-15
0-18

11,5-25
14,5-30

11,5-30
14,5-35

25-40
31-50

25-60
31-75

25-72 1)
31-90 1)

40-95
50-120

40-114 2)
50-143 2)

Fuse Class RK5 / Short-circuit current

A/kA

70/5

90/5

125/5

200/5

250/5

300/5

300/10

300/10

Fuse Class T / Short-circuit current


Rated voltage

A/kA
V

80/100
600

110/100
600

150/100
600

175/100
600

175/100
600

175/100
600

300/100 3)
600

300/100 3)
600

A600

Rated operational power


of 3-phase capacitor banks
at 60Hz (3ph)

Auxiliary Contacts (cULus)

1) Consider the max. thermal current of the contactor K3-74A: Ith 130A
2) Consider the min. cross-section of conductor at max. load
3) Class T and Class RK1
D677E

59

Contactors
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Contact Life
For selection of the suitable contactor-type according to supply voltage,
power rating and application (utilization category AC1, AC3 or AC4) use
contact life characteristic diagram.
For the most common supply voltages four scales of power ratings Pn are
provided for each utilization category.
Select contactor-type according to utilization category AC3 (breaking
current Ia = Ie) using the motor rating scales to the right, according to
utilization category AC4 (breaking current Ia = 6 x Ie) using the motor rating
scales to the left. 1)
Select contactor-type according to utilization category AC1 (breaking
current Ia = Ie/AC1) using the breaking current scale. 1)

Motor Rating
Pn /AC4

Motor Rating
Pn /AC3

For contactors frequently used under AC3/AC4-mixed service conditions


calculate contact life with the formula:
AC3

M=
1+

%AC4
100

x(

AC3
-1
AC4

M = Contact life (switching cycles) for AC3/AC4-mixed operations


AC3 = Contact life (switching cycles) for AC3 operations (normal switching conditions).
Breaking current Ia = rated motor current In.
AC4 = Contact life (switching cycles) for AC4 operations (inching).
Breaking current Ia= multiples of rated motor current In.
%AC4 = Percents of AC4-operations related to the total cycles.

Breaking Current
Ia ( = Ie/AC1)
A

Millions of Operations
Motor Rating
Pn /AC4

Motor Rating
Pn /AC3

Breaking Current
Ia ( = Ie/AC1)
A

Millions of Operations

1) Pay attention to the approved rated values of the selected contactor according to the national approvals

60

D677E

Contactors
Utilization Categories
For easier choice of devices and in order to make the comparison
of different products simplier are utilization categories for contactors
and motor-starters according to IEC 947-4-1 and VDE 0660 Part 102, for
Type of
current

Alternating
Current

Category

Typical applications

AC1

Non-inductive or
slightly inductive loads
resistance furnaces

Test conditions for the number of


on-load operating cycles
Make
Break
I/Ie
U/Ue cos Ic/Ie Ur/Ue cos

Test conditions for


making and breaking capacities
Make
Break
I/Ie
U/Ue cos Ic/Ie Ur/Ue

cos

all values

0,95

0,95

1,5 1,05

0,8

1,5 1,05

0,8

Slip-ring motors:
starting, switching off

all values

2,5

0,65

2,5

0,65

1,05

0,65

1,05

0,65

AC3

Squirrel-cage motors:
starting, switching off
motors during running

Ie
17A
17A< Ie 100A
Ie> 100A

6
6
6

1
1
1

0,65
0,35
0,35

1
1
1

0,17
0,17
0,17

0,65
0,35
0,35

10
10
10

1,05
1,05
1,05

0,45
0,45
0,35

8
8
8

1,05
1,05
1,05

0,45
0,45
0,35

AC4

Squirrel-cage motors:
starting, plugging,
inching

Ie
17A
17A< Ie 100A
Ie> 100A

6
6
6

1
1
1

0,65
0,35
0,35

6
6
6

1
1
1

0,65
0,35
0,35

12
12
12

1,05
1,05
1,05

0,45
0,45
0,35

10
10
10

1,05
1,05
1,05

0,45
0,45
0,35

AC5a

Switching of electric
discharge lamp controls

all values

1,05

0,45

1,05

0,45

AC5b

Switching of
incandescent lamps

all values

1,5 1,05

1,05

AC6a

Switching of
transformers

Ie 100A
Ie> 100A

4,5 1,05
4,5 1,05

AC6b

Switching of
capacitors

1,5 1,05

0,8

1,5 1,05

0,8

Ie 100A
Ie> 100A

8
8

1,05
1,05

0,45
0,35

6
6

1,05
1,05

0,45
0,35

AC2

AC7a
AC7b

Direct
Current

Rated
operational
current

control circuit devices and switching elements according to


IEC 947-5-1 and VDE 0660 Part 200 determind. The table offers different
utilization categories, typical applications and assorted test conditions.

Slightly inductive loads


in household appliances
and similar applications
Motor loads
for household applications

all values

1)

0,45
0,35

3,6 1,05
3,6 1,05

2)

1)

0,45
0,35

2)

AC8a

Hermetic refrigerant compressor


motor control with manual
resetting of overload releases

Ie 100A
Ie> 100A

6
6

1,05
1,05

0,45
0,35

6
6

1,05
1,05

0,45
0,35

AC8b

Hermetic refrigerant compressor


motor control with automatic
resetting of overload releases

Ie 100A
Ie> 100A

6
6

1,05
1,05

0,45
0,35

6
6

1,05
1,05

0,45
0,35

AC12

Control of resistive loads and


solid state loads with
isolation by opto couplers

all values

0,9

0.9

AC13

Control of
solid state loads with
transformer isolation

all values

10

1,1

0,65

1,1 1,1

0,65

AC14

Control of
small electromagnetic loads
(72VA)

1,1

0,7

1,1

0,7

AC15

Control of
electromagnetic load
(>72VA)

10

0,7

0,4

10

1,1

0,3

10

1,1

0,3

Make
I/Ie
U/Ue

L/R
[ms]

Break
Ic/Ie Ur/Ue

L/R
[ms]

Make
I/Ie
U/Ue

L/R
[ms]

Break
Ic/Ie Ur/Ue

L/R
[ms]

DC1

Non-inductive or
slightly inductive loads
resistance furnaces

all values

1,5

1,05

1,5

1,05

DC3

Shunt-motors:
starting, plugging, inching
dynamic braking of d.c. motors

all values

2,5

2,5

1,05

2,5

1,05

2,5

DC5

Series-motors:
starting, plugging, inching
dynamic braking of d.c. motors

all values

2,5

7,5

2,5

7,5

1,05

1,05

15

DC6

Switching of
incandescent lamps

all values

1,5 1,05

1,05

1)

DC12

Control of resistive loads and


solid state loads with
isolation by opto couplers

all values

DC13

Control of
electromagnets

all values

300

300

1,1 1,1

300

1,1 1,1

DC14

Control of
electromagnetic loads having
economy resistors in circuit

all values

10

1,1

15

1)

15

10

1,1

1
300
15

Ue Rated operational voltage, U Voltage before make, U r Recovery voltage, Ie Rated operational current, I Current make, Ic Current broken
1) Test with incandescent lamps
2) Test conditions according to standard

D677E

61

Accessories
Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660
Type
Rated insulation voltage Ui

V AC

1)

HN

HTN

HA

HB

HKT
HKA

HKF
HKB

K2-DK
K2-SK

K2-TP

K2-L 2)

690

690

690

690

690

690

690

690

690

10
6

10
6

25
20

10
6

10
-

16
-

26
-

10
-

10
6

3000
10

10

3000
10

3000
10

1200
1

3000
10

Thermal rated current Ith to 690V


Ambient temperature
max. 40C
max. 60C

A
A

Frequency of operations z
Mechanical life

1/h
S x 106

Power loss per pole at Ie/AC1

0,5

0,5

1,5

0,5

220-240V
380-400V
440V

A
A
A

3
2
1,6

3
2
1,6

6
3
2

3
2
1,6

3
2
1,5

3
2
1,5

4
3
2

3
2
1,6

500V
660-690V

A
A

1,2
0,6

1,2
0,6

2
1

1,2
0,6

1,5
1

1,5
1

2
2

1
0,5

60V
110V
220V

A
A
A

2
0,4
0,1

2
0,4
0,1

8
1
0,1

2
0,4
0,1

0,5
0,2

0,5
0,2

2,5
1,5
0,2

2
0,4
0,1

Short circuit protection


short-circuit current 1kA,
contact welding not accepted
max. fuse size
gL (gG)

Utilization category AC15


Rated operational
current Ie

Utilization category DC13


Rated operational
current Ie

20

20

25

20

10

10

10

10

For contactors with thermal overload relay or


auxiliary contacts the device with the smaller
admissible control fuse (contactor or thermal
overload relay) determines the fuse size.
Cable cross-sections
solid or stranded
flexible
flexible with multicore cable end

mm
mm
mm

0,75-2,5
0,75-2,5
0,5-1,5

0,75-2,5
0,75-2,5
0,5-1,5

solid
flexible

AWG
AWG

14 - 12
18 - 12

14 - 12
18 - 12

Cables per clamp

0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12

0,75-2,5
0,75-2,5
0,5-1,5
14 - 12
18 - 12

0,75-2,5
0,75-2,5
0,5-1,5

14 - 12
18 - 12

0,75-2,5
0,75-2,5
0,5-1,5

14 - 12
18 - 12

1-2,5
0,75-2,5
0,75-2,5

14 - 12
18 - 12

0,75-2,5
0,75-2,5
0,5-1,5

14 - 12
18 - 12

14 - 12
18 - 12

HN

HTN

HA

HB..

HKT, HKA
HKF

K2-DK
K2-SK

K2-TP

K2-L 2)

10

10

16

10

10

10

V AC

600

600

600

600

600

600

600

A600

A600

A600

A600

A600

A600

Intermittent
duty

Data according to CSA, UL and CUL


Type
Rated operational current
"General Use"
Rated operational voltage
Auxiliary Contacts

max.

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.
2) Command duration min. 30ms, 10% duty cycle, max. 30 eec.

62

D677E

Contactors and Accessories


Wiring diagrams
Auxiliary contact blocks
HN10
HA10

Snap-on momentary contact blocks


HN01
HA01

HKS11
HKA11

HN10U

HN01U

HB11

HTN10

HB02

HKF22

HTN01

HKT11

HB11, HB02:
Correct terminal marking
is given by mounting.

HKT22

Pneumatic timer

Indicator units

on-delayed

off-delayed

Coil current indicator

Voltage indicator

K2-TP..E

K2-TP..A

K2-ING
K2-INR

K2-UN
K2-UNR

red
red

Latch

Fuse holder

K2-L..

K2-F

Interface

with rectifier
K2-RF1
K2-RF3

K2-IM

red

black

Colours mentioned in
wiring diagram refer
to the outgoing
connection wires
of the device.

Regulation of switch position of aux. contakt block HKF22 for contactors K3-450 to K3-860
NO/NC overlapped

state of delivery

NO delayed

HKF22

NC

NC

NC

HKF22

NO

NO

NO

Contactor

position:
open

18

16 14 12 10

Standard position of regulation screw

D677E

18

16 14 12 10

Regulation screw position (unscrew by 4 turns)

18

16 14 12 10

Regulation screw position (screw by 4 turns)

63

Contactors
Dimensions
AC operated

DC operated

K3-10N..
K3-14N..
K3-18N..
K3-22N..

KG3-10..
KG3-14..
KG3-18..
KG3-22..

K3-24..
K3-32..
K3-40..

KG3-24..
KG3-32..
KG3-40..

K3-50..
K3-62..
K3-74..

K3-50..=
K3-62..=
K3-74..=

AC and DC operated
K3-90..
K3-115..

64

D677E

Contactors
Dimensions
AC operated, DC operated
K3-151..
K3-176..

HKA11

HKT..

K3-210..
K3-260..
K3-316..

HKA11

HKT..

K3-450..
K3-550..

Typ
K3-450
K3-550

D677E

40
40

10,5
12,5

4 233 206
6 258 228

65

Contactors
Dimensions
AC and DC operated
K3-700..
K3-860..

Typ
K3-700
K3-860

K3-1000..
K3-1200..

1)

K3-24K..
K3-32K..

K3-50K..
K3-62K..
K3-74K..

K3-90K..
K3-115K..

66

13 310 277
15 361 325

for K3-1200 in UL conformity application only

Capacitor switching contactors, AC operated


K3-18NK..

D677E

Contactors
Dimensions
Contactors DC operated
K3-10N..=
K3-14N..=
K3-18N..=
K3-22N..=

K3-24..=
K3-32..=
K3-40..=

Contactors 4-pole, AC operated


K3-10NA00-40
K3-14NA00-40
K3-18NA00-40
K3-22NA00-40

K2-23A00-40
K2-30A00-40
K2-37A00-40

Contactors 4-pole, AC operated


K2-45A00-40
K2-60A00-40

K3-116A00-40
K3-151A00-40
K3-176A00-40

Contactors 4-pole, AC and DC operated


K3-210A00-40
K3-260A00-40
K3-316A00-40

D677E

67

Contactors
Dimensions Accessories
Aux. cont. blocks, terminal blocks
HN10, HN01 K2-SK, K2-DK

Snap-on momentary cont. blocks


HTN10, HTN01

Auxiliary contact blocks


HA10, HA01

HB11, HB02

4. pole for contactors K3-200 to K3-1200


Type

NP175
NP350

223
223

148
148

26
26

52
52

98
98

5
5

122
122

M8
M8

NP325
NP500
NP760

262
294
294

148
220
220

26
53
53

55
72
72

116
138
138

5
5
5

122
152
152

M10
M12
M12

NP501
NP1000

348
348

220
220

53
53

73
73

145
145

5
8

152
152

M12
M12

NP1001

410

220

53

110

157

152

M12

Electronic timer on-delay

Electronic timer off-delay

Pneumatic timer

K2-TE..

K2-TA..

K2-TP

68

D677E

Contactors
Dimensions Accessories
Mechanical interlocks

Type

Contactor 1

LG10889
LG10889
LG10889

Contactor 2

A1

A2

A3

B1

B2

C1

C2

C3

K3-07 to K3-40
K3-07 to K3-40
KG3-07 to KG3-22 KG3-07 to KG3-22
KG3-24 to KG3-40 KG3-22 to KG3-40

45
45
45

7
7
7

45
45
45

50
80
80

50
50
50

35
35
35

17
17
17

35
35
35

4,5
4,5
4,5

4,5
4,5
4,5

LG10890
LG10890

K3-50 to K3-74
K3-50 to K3-74

K3-24 to K3-40
K3-50 to K3-74

60
60

12
12

55
60

100
100

65
100

50
50

22
22

45
50

5,5
5,5

4,5
5,5

LG11478

K3-90 bis K3-115

K3-90 bis K3-115

90

12

90

100

100

75

27

75

5,5

5,5

LG8511

K65 - K110

K65 - K110

90

12

90

100

100

75

27

75

LG11223H
LG11223H

K3-151, -176
K3-116,-151, -176

K3-151, -176
K3-116,-151, -176

110
147

30
30

110
147

130
130

130
130

100
135

40
42

100
135

6
6

6
6

3-pole contactor
4-pole contactor

LG11223H
LG11223H

K3-210, -260, -316 K3-210, -260, -316


K3-210, -260, -316 K3-210, -260, -316

145
193

30
30

145
193

160
160

160
160

120
170

55
55

120
170

6
6

6
6

3-pole contactor
4-pole contactor

LG10400H
LG10402H

K3-450, K3-550
K3-700, -860

K3-450, K3-550
K3-700, -860

220
280

42
32

220
280

220
280

220
280

110
175

152
137

110
175

9
11

9
11

LG10403H
LG10399H
LG10401H

K3-1000, -1200
K3-450, -550
K3-700, -860

K3-1000, -1200
K3-700, -860
K3-1000, -1200

334
220
280

46
37
73

334
280
334

380
220
280

380
280
380

120
110
175

260 120
144,5 175
232,5 120

LG10400V, LG10402V

LG10399V

Type

Contactor 1

Contactor 2

LG10400V
LG10402V

K3-315 - K3-550
K3-700, -860

LG10403V
LG10399V
LG10401V

K3-1000, -1200
K3-450, -550
K3-700, -860

D677E

D1

D2

13,5 13,5
9
11
11
13,5

LG10403V, LG10401V

A1

B1

B2

B3

C1

C2

C3

C4

D1

D2

K3-315 - K3-550
K3-700, -860

250
302

134
162

220
280

94
200

220
280

110
175

110
175

9
11

9
11

K3-1000, -1200
K3-700, -860
K3-1000, -1200

302
-

380
220
280

280
150
240

380
280
380

120
110
175

120
175
120

51
-

13,5 13,5
74,5
9
11
11
13,5

69

Contactors
Dimensions Accessories
Latch
K2-L..

Contactors with additional terminals


LG9339 (2 x 3 pieces)
Contactor
K3-10A to K3-22A
KG2-09A to KG2-16A

A
40
86

Indicator units

Fuse holder

Fuse holder with rectifier

K2-ING, K2-INR
K2-UN, K2-UNR

K2-RF

K2-RF1
K2-RF3

70

D677E

Contactors
Dimensions Accessories
Interface

Snap-on adapter

K2-IM

K2-SM

Suppressor units
K2-E..

VG-K2/..

RC-AD.., LG-ADZ.., LG-A03

Marking systems
marking label
P487-1 or P245-.

D677E

RC-K3 ..

label holder P527-1 with


snap-on labels LG9337

71

Contactors
Position of terminals
K3-10ND10
K3-14ND10
K3-18ND10
K3-22ND10
K3-18NK10

K3-10ND01
K3-14ND01
K3-18ND01
K3-22ND01
K3-18NK01

K3-24A00, K3-24K00
K3-32A00, K3-32K00
K3-40A00

K3-90A00
K3-115A00

K3-151A00
K3-176A00
K3-210A00
K3-260A00
K3-316A00

K3-151A00-40
K3-176A00-40
K3-210A00-40
K3-260A00-40
K3-316A00-40

KG3-10A10
KG3-14A10
KG3-18A10
KG3-22A10

KG3-10A01
KG3-14A01
KG3-18A01
KG3-22A01

KG3-10A00-40
KG3-14A00-40
KG3-18A00-40
KG3-22A00-40

K3-10ND10=
K3-14ND10=
K3-18ND10=
K3-22ND10=

K3-10ND01=
K3-14ND01=
K3-18ND01=
K3-22ND01=

K3-24A00=
K3-32A00=
K3-40A00=

K3-50A00, K3-50K00
K3-62A00, K3-62K00
K3-74A00, K3-74K00

K3-50A00=
K3-62A00=
K3-74A00=

K3-10NA00-40
K3-14NA00-40
K3-18NA00-40
K3-22NA00-40
K2-23A00-40 bis
K2-60A00-40

K3-450A22
K3-550A22
K3-700A22
K3-860A22

K85A22
K110A22

K3-1000A12
K3-1200A12

KG3-24A00
KG3-32A00
KG3-40A00

K85A21=
K110A21=

K3-1000A12=
K3-1200A12=

1) Type-suffux "EUR" with additional coil terminal


Ordering example: K3-10A10EUR 230
72

D677E

Motor Starters

D677E

Star-Delta Starters Open Type

74

Star-Delta Starters Enclosed


Enclosure for Star-Delta Starters

76
76

Accessories

77

Reversing Contactors

78

Pole Changing Starters

80

Technical Data

82

Wiring Diagrams

85

Dimensions

89

73

Star-Delta Starters Open Type


Ratings
AC3
380V
400V
415V 500V
kW
kW
7,5

AC Operated

660V
690V
kW

Rated
Current

Wired to accept
Overload Relay

AC3
400V
A

Relay

7,5

11

16

15

18,5

15

30

22

30

22

45

30

37

30

60

45

55

45

85

55

75

55

109

75

90

90

150

110

132

110

205

132

160

160

240

160

180

180

300

230
400

Type
U3/32
U12/16E K3

U3/42

U3/74

U85

U180

Coil voltage 1)
220-240V 50Hz
380-415V 50Hz

Type

Pack
pcs.

Weight
kg/pc.

K3NY15 . . .

0,9

K3NY26 . . .

0,9

K3Y40 . . .

1,4

K3Y52 . . .

1,8

K3Y80 . . .

3,5

K3Y100 . . .

3,7

K3Y140 . . .

6,6

K3Y200 . . .

K3Y240 . . .

15

K3Y300 . . .

15

Star-delta starters are wired to accept thermal overload relay. The thermal overload relay has to be ordered separately.
For full load current setting use the YD-dial of thermal overload relay.
Ordering Example: Star-Delta Starter, open type, rated AC3 at 400V 205A
rated control voltage 230V 50Hz - Order Type: K3Y200 230 + U85 120

Thermal Overload Relays


Rated Motor Current
A

Type

Pack Weight
pcs. kg/pc.

Wiring Diagram

For Star-Delta Starters K3NY15.. to K3Y40..


7
- 10,5
10,5 - 15,5
14
- 19

U12/16E 6 K3
U12/16E 9 K3
U12/16E 11 K3

1
1
1

0,10
0,10
0,10

18
23

U12/16E 14 K3
U12/16E 18 K3

1
1

0,10
0,10

- 24
- 31

manual eset

For Star-Delta Starters K3NY15.. to K3Y52..


7
- 10,5
10,5 - 15,5
14
- 19

U3/32 6
U3/32 9
U3/32 11

1
1
1

0,14
0,14
0,14

18
23
30

- 24
- 31
- 41

U3/32 14
U3/32 18
U3/32 24

1
1
1

0,14
0,14
0,14

40

- 55

U3/32 32

0,14

U3/42 20
U3/42 28
U3/42 42

1
1
1

0,30
0,30
0,30

manual and
auto reset

For Star-Delta Starters K3Y40.., K3Y52..


24
35
48

- 35
- 48
- 73

manual and
auto reset
1) Coil voltage range and other coil voltages see page 82
74

D677E

Components for Combinations


Line
Delta
Contactor
Contactor

Star
Contactor

Type

Auxiliary Contacts
Built-in for use
on Contactor
Line Delta Star
K1
K2
K3
NO/NCNO/NCNO/NC

Free Space for


Aux. Contact Blocks
on Contactor
Line
Delta Star
K1
K2
K3
HN.. or HA..

K1
Type

K2
Type

K3
Type

K3-10ND01
+ HN10

K3-10ND01

LG10889

K3NY-VB10

K3-18ND01
+ HN10

Y9A

LG10889

K3NY-VB10

K3-24A00
+ 2HN10 + HN01

Y9A

LG10889

K3Y-VB24

K3-32A00
+ HN01

K3-24A00
+ 2HN10 + HN01

Y9A

LG10889

K3Y-VB24

K3-50A00
+ HN01 + HN10

K3-50A00
+ HN01

K3-32A00
+ 2HN10 + HN01

Y9A

LG10890

K3-62A00
+ HN01 + HN10

K3-62A00
+ HN01

K3-50A00
+ 2HN10 + HN01

Y9A

LG10890

K3-90A00
+ HN01 + HN10

K3-90A00
+ HN01

K3-90A00
+ 2HN10 + HN01

Y9AL

LG11478

K3-115A00
+ HN01 + HN10

K3-115A00
+ HN01

K3-90A00
+ 2HN10 + HN01

Y9AL

LG11478

K3-151A00
+ HKT11

K3-151A00
+ HKT11

K3-151A00
+ HKT22

Y9AL

LG11223H

1/-

-/1

K3-176A00
+ HKT11

K3-176A00
+ HKT11

K3-151A00
+ HKT22

Y9AL

LG11223H

1/-

-/1

Electronic Mechanical
Timer
Interlock
between
K4
K2 and K3
Type
Type

Star-Delta
Starter
Connector

K3-10ND10
+ HN10 + HN01

Y9A

K3-18ND01

K3-14ND10
+ HN10 + HN01

K3-24A00
+ HN10 + HN01

K3-24A00
+ HN01

K3-32A00
+ HN10 + HN01

Applications

Time setting

The star-delta starting method is only practicable in such cases where the
motor windings are connected in delta configuration for normal operation
and the torque which is needed during the starting period is not higher
than approx. 30% of the rated torque. The starting current drawn from the
line will be approx. 2 to 2,7 times the rated motor current.

The transition from start (star configuration) to normal operation (delta


configuration) should be after the motor achieves practically full rotational
speed. The use of star-delta timer Y9A with a dwell period of approx. 25ms
provides a careful operation of motor and drive equipment.

Thermal Overload Relays


Rated Motor Current
A

Type

Pack Weight
pcs. kg/pc.

Wiring Diagram

For Star-Delta Starters K3Y80.., K3Y100..


35
48
70

- 48
- 73
- 90

U3/74 28
U3/74 42
U3/74 52

1
1
1

0,40
0,40
0,40

90

-112

U3/74 65

0,40

1
1

0,90
0,90

1,5

manual and
auto reset

For Star-Delta Starters K3Y140.., K3Y200..


104
140

-156
-207

U85 90
U85 120

manual eset

For Star-Delta Starters K3Y240.., K3Y300..


208 - 312

U180 180

manual and
auto reset

D677E

75

Star-Delta Starters Enclosed Type


Ratings
AC3
380V
400V
415V 500V
kW
kW

AC Operated
Rated
Current

660V
690V
kW

Optional
Extras

Wired
to accept
Overload
Relay

AC3
400V
A

Type
230
400

Type

Coil voltage 1)
220-240V 50Hz
380-415V 50Hz
Pack
pcs.

Weight
kg/pc.

Plastic Enclosed, protected to IP65


15

18,5

15

30

ST

U3/32

K3NY26P . . .

1,8

22

30

22

45

ST, H

U3/42

K3Y40P . . .

3,8

30

37

30

60

ST, H

K3Y52P . . .

4,2

45

55

45

85

ST, H

K3Y80P . . .

5,9

55

75

55

109

ST, H

K3Y100P . . .

8,7

U3/74

Sheet Steel Enclosed, protected to IP54


15

18,5

15

30

ST, H

U3/32

K3NY26B . . .

4,8

22

30

22

45

ST, H

U3/42

K3Y40B . . .

4,8

30

37

30

60

ST, H

K3Y52B . . .

5,2

45

55

45

85

ST, H

K3Y80B . . .

15

55

75

55

109

ST, H

K3Y100B . . .

15

75

90

90

150

ST, H

K3Y140B . . .

22

110

132

110

205

ST, H

K3Y200B . . .

22

U3/74

U85

1) Coil voltage range and other coil voltages see page 82


Type-suffix for optional extras
Start-Stop Push Buttons . . . . . . .T . . .
Selector Switch
Typical wiring diagrams see page 86
Control Circuit Fuse

<250V (1 piece)
>250V (2 pieces)

Run Hour Meter

. . . . . . .W . . .
. . . . . . .ST . . .
. . . . . . .ST . . .
. . . . . . .H . . .

Ordering Example: Star-Delta Starter, steel sheet enclosed, with selector switch and run hour meter
rated AC3 at 400V 82A, rated control voltage 230V 50Hz - Order Type: K3Y80BWH 230 + U3/74 52

Enclosures for Star Delta Starter


for Starter

accept
Overload Relay

Type

Pack
pcs.

Weight
kg/pc.

U3/32
U3/42, U3/32

K3Y26P-G3
K3Y40/52P-G3

1
1

1,0
2,4

U3/32
U3/42, U3/32

K3Y26B-G3
K3Y40/52B-G3

1
1

3,4
3,4

Plastic IP65
K3Y15, K3Y26
K3Y40, K3Y52

Sheet Steel IP54


K3Y15, K3Y26
K3Y40, K3Y52

76

D677E

Star-Delta Starter Connector


For Star-Delta Starter Types

Type

K3NY15, K3NY26
K3Y40, K3Y52

K3NY-VB10
K3Y-VB24

Pack
pcs.
1
1

Weight
kg/pc.
0,02
0,03

Additional Terminals
For Star-Delta Starter Types
Line Conn.
Motor Conn.
Line Contactor
Overload Relay

Cable
cross-section
mm

Type

Pack

Weight

pcs.

kg/pc.

Single pole with Fingertouch Protection


K3Y15, K3Y26

U12/16

0,75 - 10 solid LG9339


0,75 - 6 flex.

0,009

LG7559

0,052

Three-pole with Fingertouch Protection


U3/42

4 - 35 strand.
4 - 25 flex.

Electronic Timers for Star-Delta Starters


Rated Control
Voltage
V

Time Range Delay Time Rated Current AC15


230V 400V
s
ms
A
A

Type

24 - 60V AC
110 - 415V AC

1 - 20
1 - 20

20 - 25
20 - 25

6
6

4
4

Y9A 60
Y9A 415

1
1

0,075
0,075

24 - 60V~
110 - 415V~

1 - 20
1 - 20

40 - 80
40 - 80

6
6

4
4

Y9AL 60
Y9AL 415

1
1

0,075
0,075

Time repeat accuracy

1%

Minimum interval between operations

2s

Short circuit protection

4A gl (gG)

Power consumption at

24V
60V
220-240V
380-415V

Pack

Weight

pcs.

kg/pc.

0,2VA
5VA
2VA
7VA

Mounting Bar
Specification

Type

For screw mounting of electronic timer Y9..

LG7735

Pack
pcs.
10

Weight
kg/pc.
0,09

Star-Delta Starters in Special Versions


Starters for Longer Starting Time
For longer starting times the thermal overload relay is mounted on delta-contactor. The motor is not protected in
Y-connection. The timer used for this starter-type is the type Y91A, time range is 10 to 60s.
Principal wiring diagram see page 86.
Ordering Example: K3YL52 230

Starters with two Thermal Overload Relays on request


Basic circuit diagram see page 86

D677E

77

Reversing Contactors with Mechanical Interlock


Ratings
AC3
380V
400V
415V
500V
kW
kW

Rated
Current
660V
690V
kW

AC3
400V
A

5,5

10

7,5

18

AC Operated
Coil voltage 1)
110V 50Hz
220-240V 50Hz
380-415 50Hz
Pack
pcs.

Wired
to accept
Overload
Relay
page 102
Type

Type

U3/32
U12/16E K3

K3NWU10 . . .

0,6

K3NWU18 . . .

0,6

K3WU24 . . .

1,2

K3WU32 . . .

1,4

K3WU50 . . .

2,5

110
230
400

Weight>
kg/pc.

Open Type
4
7,5

5,5
10

11

15

15

24

15

18,5

18,5

32

22

30

30

50

30

37

37

62

K3WU62 . . .

2,5

37

45

45

74

K3WU74 . . .

2,5

K3WU10B . . .

3,9

K3WU18B . . .

4,1

K3WU24B . . .

4,5

K3WU32B . . .

4,7

K3WU50B . . .

7,1

K3WU62B . . .

7,1

U3/42

U3/74

Sheet Steel Enclosed, protected to IP54


4
7,5

5,5
10

5,5

10

7,5

18

11

15

15

24

15

18,5

18,5

32

22

30

30

50

30

37

37

62

U3/32

U3/42

U3/74

Reversing Starter Connector


For Reversing Starter Types

Type

K3WU10, K3WU18
K3WU24, K3WU32

K3NW-VB10
K3W-VB24

Pack
pcs.
1
1

1) Other coil voltages see page 39


78

D677E

Weight
kg/pc.
0,02
0,025

Components for Combinations


Left Hand Side
Right Hand Side
Contactor
Contactor

Mechanical
Interlock

Reversing
Starter
Connector

Auxiliary Contacts
Built-in for use
on Contactor

Free Space for


Aux. Contact Blocks
on Contactor

K1
Type

K2
Type

Type

Type

K1
NO/NC

K2
NO/NC

K1
K2
HN.. or HA..

K3-10ND10
+ HN01

K3-10ND10
+ HN01

LG10889

K3NW-VB10

K3-18ND10
+ HN01

K3-18ND10
+ HN01

LG10889

K3NW-VB10

K3-24A00
+ HN10 + HN01

K3-24A00
+ HN10 + HN01

LG10889

K3W-VB24

K3-32A00
+ HN10 + HN01

K3-32A00
+ HN10 + HN01

LG10889

K3W-VB24

K3-50A00
+ HN10 + HN01

K3-50A00
+ HN10 + HN01

LG10890

K3-62A00
+ HN10 + HN01

K3-62A00
+ HN10 + HN01

LG10890

K3-74A00
+ HN10 + HN01

K3-74A00
+ HN10 + HN01

LG10890

K3-10A10
+ HN01

K3-10A10
+ HN01

LG10889

K3W-VB10

K3-18A10
+ HN01

K3-18A10
+ HN01

LG10889

K3W-VB10

K3-24A00
+ HN10 + HN01

K3-24A00
+ HN10 + HN01

LG10889

K3W-VB24

K3-32A00
+ HN10 + HN01

K3-32A00
+ HN10 + HN01

LG10889

K3W-VB24

K3-50A00
+ HN10 + HN01

K3-50A00
+ HN10 + HN01

LG10890

K3-62A00
+ HN10 + HN01

K3-62A00
+ HN10 + HN01

LG10890

D677E

79

Reversing Contactors for North America


Ratings
AC3
380V
400V
415V
500V
kW
kW

AC Operated

Rated
Current
660V
690V
kW

AC3
400V
A

5,5

10

Coil voltage 1)
220-240V 50Hz
380-415V 50Hz

Wired
to accept
Overload
Relay
page 102
Type

Type

U3/32
U12/16E K3

KNW3-10 . . .

0,6

KNW3-18 . . .

0,6

KW3-24 . . .

1,2

230
400

Pack
pcs.

Weight>
kg/pc.

Open Type
4
7,5

5,5
10

10

18

11

15

15

24

15

18,5

18,5

32

KW3-32 . . .

1,4

18,5

18,5

18,5

40

KW3-40 . . .

1,4

U3/42

Pole Changing Starters

AC Operated

Ratings
AC3 at
380V
400V
415V
500V
kW
kW

Rated
Current
660V
690V
kW

AC3
400V
A

Wired
to accept
Overload
Relay
page 102
Type

Type
230
400

Coil voltage 1)
220-240V 50Hz
380-415V 50Hz
Pack
pcs.

Weight>
kg/pc.

Open Type
7,5

10

10

18

11

15

15

24

15

18,5

18,5

32

22

30

30

50

30

37

37

62

K3NPU18 . . .

1,0

K3NPU24 . . .

1,5

2 x U3/32

K3PU32 . . .

1,9

2 x U3/74

K3PU50 . . .

3,9

K3PU62 . . .

3,9

K3NPU18B . . .

1,0

2 x U3/32
2 x U12/16E K3

Sheet Steel Enclosed, protected to IP54


7,5

10

7,5

18

2x U3/32

11

15

15

24

K3NPU24B . . .

1,5

15

18,5

18,5

32

K3PU32B . . .

1,9

1) Other coil voltages see page 40


Ordering Example: Pole Changing Starter, open version, rated AC3 at 400V 28A and 15A, control voltage 230V 50Hz
Order Type:
K3PU32 230 + U3/32 32 + U3/32 18

Pole Changing Starters for Star-Delta Operation on request

1) Other coil voltages see page 39


80

D677E

Components for Combinations


Left Hand Side
Right Hand Side
Contactor
Contactor

Mechanical
Interlock

Auxiliary Contacts
Built-in for use
on Contactor

Free Space for


Aux. Contact Blocks
on Contactor

K1
Type

K2
Type

Type

K1
NO/NC

K2
NO/NC

K1
K2
HN.. or HA..

K3-10ND01

K3-10ND01

LG10889

K3-18ND01

K3-18ND01

LG10889

K3-24A00
+ HN01

K3-24A00
+ HN01

LG10889

K3-32A00
+ HN01

K3-32A00
+ HN01

LG10889

K3-40A00
+ HN01

K3-40A00
+ HN01

LG10890

Components for Combinations


High
Low
Speed
Speed

Star
Contactor

K1
Type

K2
Type

K3
Type

Free Space for


Aux. Contact Blocks on Contactor
High
Low
Star
Speed
Speed
K1
K2
K3
HN.. or HA..

K3-18ND01
+ 2 x HN10

K3-18ND01
+ HN10

K3-14ND10

K3-24A00
+ HN01 + 2 x HN10

K3-24A00
+ HN01 + HN10

K3-18ND10

K3-32A00
+ HN01 + 2 x HN10

K3-32A00
+ HN01 + HN10

K3-24A00
+ HN10

K3-50A00
+ HN01 + 2 x HN10

K3-50A00
+ HN01 + HN10

K3-32A00
+ HN10

K3-62A00
+ HN01 + 2 x HN10

K3-62A00
+ HN01 + HN10

K3-50A00
+ HN10

K3-18ND01
+ 2 x HN10

K3-18ND01
+ HN10

K3-14ND10

K3-24A00
+ HN01 + 2 x HN10

K3-24A00
+ HN01 + HN10

K3-18ND10

K3-32A00
+ HN01 + 2 x HN10

K3-32A00
+ HN01 + HN10

K3-24A00
+ HN10

D677E

81

Star-Delta Starters
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Type

K3NY15 K3NY26

K3Y40

K3Y52

K3Y80

690

690

690

Main Contacts
Rated insulation voltage Ui 1)

V AC

Frequency of operations z AC3, Ie


Change-over time max. (Y-step)

1/h
s

Utilization category AC3


Switching of three-phase motors
Rated operational
220-230V
current Ie
240V
380-400V

A
A
A

16
16
16

30
30
30

45
45
45

60
60
60

85
85
85

415-440V
500V
660-690V

A
A
A

15
15
13

30
30
17

45
45
30

60
60
36

690

690

K3Y100 K3Y140 K3Y200 K3Y240 K3Y300


690

690

690

690

690

109
109
109

150
150
150

205
205
205

240
240
240

300
300
300

85
85
57

109
95
72

150
150
103

205
205
118

240
190
147

300
240
180

15
20 (Type K3YL ... 60)

Rated operational power 220-230V


of three-phase motors
240V
50-60Hz
380-400V

kW
kW
kW

4
5,5
7,5

7,5
11
15

11
15
22

15
18,5
30

22
22
45

30
30
55

45
45
75

55
55
110

75
75
132

90
90
160

415-440V
500V
660-690V

kW
kW
kW

7,5
7,5
11

15
18,5
15

22
30
22

30
37
30

45
55
45

55
75
55

75
90
90

110
132
110

140
132
132

170
180
180

Cable cross-sections
Line
solid or stranded
flexible
lexible with multicore cable end

mm
mm
mm

1,5 - 6 2)
1,5 - 4 2)
1,5 - 4 2)

1,5 - 16
1,5 - 16
1,5 - 16

10 - 70 3)
16 - 50 3)
10 - 35

10 - 120
10 - 95
10 - 95

busbar
18x5
M8

mm
mm
mm

1,5 - 6
1,5 - 4
1,5 - 4

1,5 - 16
1,5 - 16
1,5 - 16

4 - 35 3)
6 - 25 3)
4 - 25

10 - 120
10 - 95
10 - 95

busbar
18x5
M8

55
20
6

130
26
8

183
36
14

560
10
10

700
10
10

Motor
solid or stranded
flexible
lexible with multicore cable end

Power consumption of the combination


inrush and change-over VA
sealed VA
W

Coil Voltage Ranges and Non Standard Voltages for Star-Delta Starters

K3NY15.. to K3Y100..
Suffix to
Star-Delta Starter
type
e.g. K3Y80 400

K3Y140, to K3Y300..
Rated Control Voltage Us
range for 50Hz
range for 60Hz
min.
max.
min.
max.
V
V
V
V

Suffix to
Star-Delta Starter
type
e.g. K3Y300 230

Rated Control Voltage Us


range for 50Hz
range for 60Hz
min.
max.
min.
max.
V
V
V
V

for DC
V

24
42
110

24
42
100

24
47
110

24
47
110

27
52
122

24
48
110

24
48
110

24
48
120

24
48
110

24
48
120

24
48
110

180
230
400

180
220
380

210
240
415

200
230
400

240
264
415

230
400

220
380

240
415

220
380

240
415

220
-

Standard voltages in bold type letters

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution


degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.
2) Additional terminals see page 77
3) Maximum cable cross-section with prepared conductor

82

D677E

Reversing Starters
Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Type

K3NWU10 K3NWU18

K3WU24

K3WU32

K3WU50

K3WU62

K3WU74

690

690

690

690

690

690

12
11,5
11

18
18
18

23
24
24

30
32
32

45
50
50

63
62
62

74
74

10
9
9
6,5

18
18
16
8,5

24
23
23
17

32
30
30
20

50
50
45
31

62
62
60
40

74
74
74
40

220-230V kW
240V kW
380-400V kW

3
3
4

5
5
7,5

6
7
11

8,5
9
15

12,5
13,5
22

18,5
19
30

23
37

415-440V kW
500V kW
660-690V kW

4,5
5,5
5,5

8,5
10
10

12
15
15

16
18,5
18,5

24
30
30

33
37
37

40
45
45

Main Contacts
Rated insulation voltage Ui 1)

V AC

Utilization category AC3


Switching of three-phase motors
Rated operational current Ie
220V A
230V A
240V A
380-400V
415-440V
500V
660-690V
Rated operational power
of three-phase motors
50-60Hz

A
A
A
A

690

Cable cross-sections
Line
solid or stranded mm
flexible mm
flexible with multicore cable end mm
Cables per clamp

0,75 - 6
1-4
0,75 - 4
1

1,5 - 25
2,5 - 16
1,5 - 16
1

4 - 50
6 - 35
6 - 35
1

Power consumption of the combination


inrush and change-over VA
sealed VA
W

33 - 45
7 - 10
2,6 - 3

90 - 115
9 - 13
2,7 - 4

140 - 185
13 - 18
5,4 - 7

Technical Data according to UL508


Main Contacts (cULus)

Type

Rated operational power


of three-phase motors
at 60Hz (3ph)

110-120V
200V
220-240V
277V

KNW3-10

hp
hp
hp
hp

1
3
3
3

380-415V hp
440-480V hp
550-600V hp

5
5
7

Fuse / Short-circuit current

A/kA

Rated voltage

Auxiliary Contacts (cULus)


Cable cross-sections
for main connectors

solid AWG
flexible AWG

Cables per clamp

KNW3-18
2
5
7
7

KW3-24

KW3-32

KW3-40

5
7
10
7

5
10
10
10

7
10
15
15

10
10
15

10
15
20

15
20
25

20
25
30

30/5

50/5

90/5

125/5

175/5

600

600

600

600

600

A600

A600

A600

A600

A600

18 - 10
18 - 10
1

16 - 10
14 - 4
1

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.

D677E

83

Pole Changing Starters


Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1
Type
Main Contacts
Rated insulation voltage Ui 1)

V AC

Utilization category AC3


Switching of three-phase motors
Rated operational current Ie
220V A
230V A
240V A
380-400V A
415V A
440V A
500V A
660V A
690V A
Rated operational power
of three-phase motors
50-60Hz

K3NPU18

K3NPU24

K3PU32

K3PU50

K3PU62

690

690

690

690

690

18
17,5
17

23
23
23

30
30
30

45
45
45

63
60
60

16
16
16

23
23
23

30
30
30

45
45
45

60
60
60

16
9
8,5

23
17,5
17

30
21
20

45
33
31

55
42
40

220-230V kW
240V kW
380-400V kW

5
5
7,5

6
7
11

8,5
9
15

12,5
13,5
22

18,5
19
30

415-440V kW
500V kW
660-690V kW

8,5
10
7,5

12
15
15

16
18,5
18,5

24
30
30

33
37
37

Cable cross-sections
Line
solid or stranded mm
flexible mm
flexible with multicore cable end mm
cables per clamp
Power consumption of the combination
inrush and change-over VA
sealed VA
W

0,75 - 6
1-4
0,75 - 4
1

1,5 - 25
2,5 - 16
1,5 - 16
1

4 - 50
6 - 35
6 - 35
1

55
20
6

128
26
8

178
31
11

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request.

84

D677E

Star-Delta Starters
Wiring Diagrams Main Circuit
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and circuits as broken lines are not included.
K3NY15 to K3Y100
with thermal overload relay U3/.. or U12/16

K3Y140 to K3Y300
with thermal overload relay U85 or U180

Wiring Diagrams Control Circuit


K3NY15 to K3Y52
operating with control switch

K3Y15 to K3Y52
operating with push buttons

K3Y80 to K3Y200
operating with control switch

K3Y80 to K3Y200
operating with push buttons

K3Y240 to K3Y300
operating with control switch

K3Y240 to K3Y300
operating with push buttons

D677E

85

Star-Delta Starters
Wiring Diagrams Main Circuit
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and control circuits as broken lines are not included.
K3YL..
Typical circuit diagram

K3Y.. with 2 Thermal Overload Relays


Typical circuit diagram

Wiring Diagrams Control Circuit


with selector switch
K3Y..W
Typical circuit diagram
operating with control switch

86

Typical circuit diagram


operating with push buttons

with push buttons


K3Y..T
Typical circuit diagram

D677E

Reversing Contactors
Wiring Diagrams Main Circuit
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and control circuits as broken lines are not included.
K3NWU10 to K3WU74
with thermal overload relay U3/32, U3/42 or U3/74

Wiring Diagrams Control Circuit


K3NWU10 to K3WU32
operating with control switch

K3WU50, K3WU62, K3WU74


operating with control switch

D677E

operating with push buttons


Reversing over off-position

Reversing direct

operating with push buttons

87

Pole Changing Starters


Wiring Diagrams
Terminal markings of contactors and relays according to DIN EN 50012
Connections shown in main and control circuits as broken lines are not included.
Main Circuit

Operation
Speed relation
Power relation

88

Principal Control Circuit Wiring Diagram


operating with control switch

operating with push buttons

Low
speed

High
speed

Low
speed

High
speed

Delta
1
1

Double-Star
2
1,5 - 1,8

Star
1
0,3

Double-Star
2
1

D677E

Star-Delta Starters
Dimensions
Star-Delta Starters, AC operated, open type
K3Y15 + U3/32
K3Y26

K3Y15 + U12/16E G3
K3Y26

K3Y40 + U3/32
K3Y52 + U3/32

K3Y40 + U3/42
K3Y52 + U3/42

K3Y80 + U3/74

K3Y100 + U3/74

K3Y140 + U85
K3Y200

K3Y240 + U180 + SU180/176


K3Y300

D677E

89

Star-Delta Starters
Dimensions
Star-Delta Starters, plastic enclosed, protected to IP65
K3Y26P

K3Y40P to K2Y100P

2 x 50,5/25,5 + 20,5

Type

K3Y40P
K3Y52P

300 346 180


300 346 180

272 320
272 320

6,5
6,5

32,5
32,5

32,5
32,5

60
60

60
60

K3Y80P
K3Y100P

300 446 180


300 446 180

272 420
272 420

6,5
6,5

40,5
50,5

40,5
40,5

70
70

70
70

Star-Delta Starters, sheet steel enclosed, protected to IP54


K3Y26B to K3Y52B
Type

K3Y26B
K3Y40B
K3Y52B

25,5
32,5
32,5

25,5
32,5
32,5

Mounting by included fixing link

K3Y80B to K2Y200B
Type

K3Y80B
K3Y100B

380 380 210


380 380 210

340 340
340 340

8,7 65
8,7 65

K3Y140B
K3Y200B

380 600 210


380 600 210

560 340
560 340

8,7 65
8,7 65

Type

K3Y80B
K3Y100B

40,5
50,5

40,5
40,5

70
80

70
70

60
60

K3Y140B
K3Y200B

50,5
50,5

50,5
50,5

80
80

80
80

70
70

90

D677E

Reversing Contactors
Dimensions
Reversing Starters, AC operated, open type
K3WU10 + U3/32
K3WU18

K3WU10 + U12/16E G3
K3WU18

K3WU24 + U3/32
K3WU32
K3WU40

K3WU24 + U3/42
K3WU32
K3WU40

K3WU50 + U3/74
K3WU62
K3WU74

Reversing Contactors, sheet steel enclosed, protected to IP54


Type

K3WU18B
K3WU24B
K3WU32B

300
300
300

300
300
300

150
150
150

250
250
250

250
250
250

30
30
30

30
30
30

25,5
32,5
32,5

41
41
41

K3WU50B
K3WU62B

300
300

300
300

150
150

250
250

250
250

40
40

40
40

32,5
32,5

59
59

Mounting by included fixing link

D677E

91

Pole Changing Starters


Dimensions
Pole Changing Starters, AC operated, open type
K3PU18 + 2x U3/32

K3PU18 + 2x U12/16

K3PU24 +2x U3/32


K3PU32

K3PU50 + 2x U3/74
K3PU62

Pole Changing Starters, sheet steel enclosed, protected to IP54


K3PU18B to K3PU32B
Type

K3PU18B
K3PU24B
K3PU32B

25,5
32,3
32,3

25,5
32,5
32,5

Mounting by included fixing link

92

D677E

D.O
.L
.O.L
.L.. Starters

D677E

D.O.L. Starters With Start-Stop Buttons

94

D.O.L. Starters With Selector Switch

94

D.O.L. Starters With Selector Switch And


Pneumatic Switch For Use In Moist Rooms

94

Enclosures

95

Accessories

95

Wiring Diagrams

96

Dimensions

98

93

D.O.L. Starters In Plastic Enclosure


Ratings
AC3 at
380V
400V
415V
kW

Included Free
Contactor Space
f. Aux.
Cont.
HN..
Type
pcs.

Wired
Protec- Conduit
to
tion
Entries
accept Degree
Overload
Relay
Type

Type

Coil voltage 1)
230 220-240V 50Hz 230-264V 60Hz
400 380-415V 50Hz 400-440V 60Hz

Pack Weight

W
pcs.
kg/pc.

D.O.L. Starters with Start-Stop/Reset Push Buttons


4

K3-10ND10 2

U12/16 K3 IP65

20,5mm

P1T10 . . .

0,6

7,5

K3-18ND10 2

U12/16 K3 IP65

20,5mm

P1T18 . . .

0,6

K3-22ND10 2

U12/16 K3 IP65

20,5mm

P1T22 . . .

0,6

11

D.O.L. Starters with Selector Switch


4

K3-10ND10 2

U12/16 K3 IP65

20,5mm

P1W10 . . .

0,6

7,5

K3-18ND10 2

U12/16 K3 IP65

20,5mm

P1W18 . . .

0,6

K3-22ND10 2

U12/16 K3 IP65

20,5mm

P1W22 . . .

0,6

0,6

11

D.O.L. Starters with Selector Switch and Pneumatic Switch for moist rooms
7,5

K3-18ND10 2

U12/16 K3 IP65

20,5mm

P1W18P . . .

Push button and tube on request


Ordering Example:

D.O.L. Starter with selector switch, plastic enclosed, rated AC3 at 400V 15,5A,
rated control voltage 230V 50Hz - Order Type: P1W18 230 + U12/16E 18 K3

Thermal Overload Relays


Setting range
A

Type

Pack Weight
pcs. kg/pc.

0,12 - 0,18
0,18 - 0,27
0,27 - 0,4

U12/16E 0,18 K3
U12/16E 0,27 K3
U12/16E 0,4 K3

1
1
1

0,10
0,10
0,10

0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U12/16E 0,6 K3
U12/16E 0,9 K3
U12/16E 1,2 K3

1
1
1

0,10
0,10
0,10

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U12/16E 1,8 K3
U12/16E 2,7 K3
U12/16E 4 K3

1
1
1

0,10
0,10
0,10

4
6
8

- 6
- 9
- 11

U12/16E 6 K3
U12/16E 9 K3
U12/16E 11 K3

1
1
1

0,10
0,10
0,10

10
13
17

- 14
- 18
- 23

U12/16E 14 K3
U12/16E 18 K3
U12/16E 23 K3

1
1
1

0,10
0,10
0,10

22

- 30

U12/16E 30 K3

0,13

Overload Relays with Quick Tripping Characteristic see page 103


Technical data see contactors page 44 and thermal overload relays page 107
1) Non-standard coil voltages see page 39
94

D677E

manual reset

Enclosures for Contactors


Suitable for
contactor

Protection Conduit Entries


Degree
Top
Bottom

Type

K3-07.. to K3-22..
K3-24..1) to K3-40.. 1)

IP65

P1

2 x 20,5mm 2 x 20,5mm

Pack
pcs.
1

Weight
kg/pc.
0,35

Enclosures for D.O.L. Starters with reset button


Suitable for
contactor

Protection Conduit Entries


Degree
Top
Bottom

Type

K3-10.. to K3-22..
+U12/16.. K3

IP65

P1R

2 x 20,5mm 2 x 20,5mm

Pack
pcs.
1

Weight
kg/pc.
0,35

Indicator Units
Specifications

Voltage Range

Type

Pack
pcs.

Weight
kg/pc.

Coil Current Indicator


Indicator, green (LED)
24 - 660V AC/DC
Coil Current Indicator,
Indicator red (LED)
24 - 660V AC/DC
To be connected in series with the contactor coil. In case of coil
interruption the indicator goes out. Voltage drop approx. 2 volts

K2-ING
K2-INR

10
10

0,02
0,02

Voltage Indicator
Indicator, clear (glow-disc. l.) 220 - 415V AC/DC
Indicator, red (LED)
24 - 120V AC/DC
Voltage Indicator
To be connected parallel to the contactor coil. In case of
applied voltage the indicator also lights at coil interruption.

K2-UN
K2-UNR

10
10

0,02
0,02

LG9743T
LG9743R
LG9743GR

10
10
10

0,005
0,005
0,005

Lens Caps For Indicator Units


Lens cap transparent
Lens cap red
Lens cap green
Mounting instructions see page 100

Heating Element
Specifications

Voltage Range
Power Consumption

Type

To avoid condensed water on places


where high humidity is given together
with alterations of ambient temperature

380 - 415V, 1,5W


220 - 240V, 1,5W

K2-HR
K2-HR 230

Pack
pcs.
10
10

Weight
kg/pc.
0,02
0,02

Additional Terminals, Start Contact


Specification

Type
Cable Cross-sections to clamp mm
solid or
flexib. w. multistranded
flexible
core cable end

Neutral Terminal
2 x 0,75-4 2 x 0,75-2,5
Earth Terminal
2,5-16
1,5-10
Mounting instructions see page 100
Start Contact

1)

for contactor
K3-10 to K3-22

2 x 0,5-2,5
1,5-10

to be snapped on top of
the auxiliary contact

Pack

Weight

pcs.

kg/pc.

LG9744
LG9750

10
10

0,009
0,052

LG9319-K3

10

0,03

without auxiliary contact blocks


D677E

95

D.O.L. Starters
Wiring Diagrams Main Circuit
All fuses F0 shown in the main circuits are not included.
Terminal markings according to EN 50012
P1...
with overload relay U12/16.. K3

Wiring for single phase motors

Wiring Diagrams Control Circuit


D.O.L. Starters P1 with standard coil voltages (see page 94) are supplied with connectors between main circuit and control circuit.
Coil connectors
60Hz The starter is supplied with
Coils for 380-415V 50Hz and 400-440V 60Hz:
control circuit connectors between terminals1 (L1) and 5 (L3).
60Hz The starter is supplied with
Coils for 220-240V 50Hz and 230-264V 60Hz:
control circuit connectors between terminals 95 and 5 (L3). Connect
neutral wire to terminal A1.
Coils for other voltages
voltages: Without connectors between supply and control
circuit. Connect supply to terminals A1 and 95.

Separate coil supply


Coils for 380-415V 50Hz and 400-440V 60Hz
60Hz: Remove connectors A1-1
and 95-5, connect supply to terminals A1 and 95.
Coils for 220-240V 50Hz and 230-264V 60Hz
60Hz: Remove connectors 95-5
connect supply to terminals A1 and 95.
Coils for other voltages
voltages: Connect supply to terminals A1 and 95.

Coil phase to phase


(380-415V 50Hz)

Coil phase to phase

local control
or remote control

Coil phase to neutral


(220-240V 50Hz)

local control
or remote control

Coil phase to neutral

local control
or remote control

local control
or remote control

D.O.L. Starters with remote control


P1..
Remote 2-wire (switch) control

96

Remote 3-wire (push button) control

Remote start-stop control


(3 control stations)

D677E

D.O.L. Starters
Wiring Diagrams Control Circuits
Typical circuit diagram (for separate coil supply, control circuit connected between L1 and N)
Terminal markings according to EN 50012
D.O.L. Starters with Start-Stop/Reset Push Buttons
P1T10, P1T18, P1T22
with overload relay U12/16.. K3

P1T10, P1T18, P1T22


with external push buttons

D.O.L. Starters with Selector Switch


P1W10, P1W18, P1W22
with external control switch

P1W10, P1W18, P1W22


with external push buttons

D.O.L. Starters with Selector Switch and Pneumatic Switch


for Swimmingpool Control Gear and for use in Moist Rooms
P1W18P
with overload relay U12/16.. K3

push button
ON/OFF

D677E

97

D.O.L. Starters
Dimensions
D.O.L. Starters with Start-Stop/Reset Push Buttons, Plastic Enclosed

D.O.L. Starters with Selector Switch, Plastic Enclosed

P1T.., P1TP..

P1W.., P1W18P

P1W18P: plug-in for air tube inside diameter 3mm


Rear Conduit Entries
knockouts
4 x 23

98

D677E

Enclosures
Dimensions
Enclosures for Contactors

Enclosures for D.O.L. Starters

P1

P1R, P1P

Rear Conduit Entries


knockouts
4 x 23

D677E

99

D.O.L. Starters
Mounting and Wiring Instructions
Indicators and Lens Caps for D.O.L. Starters P1

K2-UN., K2-IN.

LG9743.

Wiring Examples
Coil Current Indicator

Voltage Indicator

Heating Element

K2-ING
K2-INR

K2-UN
K2-UNR

K2-HR

red

K2-HR 230

red

Colour mentioned in wiring diagrams refer to


the outgoing connection wire of the device.

Earth Terminal LG9750 for K2-23 and K2-30 in Enclosure P1

Neutral Terminal LG9744

for K2-23 and K2-30 remove spacing piece

LG9750

LG9744

100

D677E

Thermal Overload Relays

D677E

Thermal Overload Relays for Direct Mounting

102

Thermal Overload Relays for Separate Mounting

104

Accessories

105

Technical Data

106

Dimensions

111

101

Thermal Overload Relays for plug-in mounting


Setting Range
D.O.L. (A)

Type
(A)

Pack Weight
pcs. kg/pc.

Wiring Diagram

With Manual Reset


Reset, for contactors K1-..
0,12 - 0,18
0,18 - 0,27
0,27 - 0,4

U12/16E 0,18 K1
U12/16E 0,27 K1
U12/16E 0,4 K1

1
1
1

0,10
0,10
0,10

0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U12/16E 0,6 K1
U12/16E 0,9 K1
U12/16E 1,2 K1

1
1
1

0,10
0,10
0,10

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U12/16E 1,8 K1
U12/16E 2,7 K1
U12/16E 4 K1

1
1
1

0,10
0,10
0,10

4
6
8

- 6
- 9
- 11

7
- 10,5
10,5 - 15,5
14
- 19

U12/16E 6 K1
U12/16E 9 K1
U12/16E 11 K1

1
1
1

0,10
0,10
0,10

10

- 14

18

U12/16E 14 K1

0,10

- 24

manual reset

With Auto Reset


Reset, for contactors K1-..
0,12 - 0,18
0,18 - 0,27
0,27 - 0,4

U12/16A 0,18 K1
U12/16A 0,27 K1
U12/16A 0,4 K1

1
1
1

0,10
0,10
0,10

0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U12/16A 0,6 K1
U12/16A 0,9 K1
U12/16A 1,2 K1

1
1
1

0,10
0,10
0,10

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U12/16A 1,8 K1
U12/16A 2,7 K1
U12/16A 4 K1

1
1
1

0,10
0,10
0,10

4
6
8

- 6
- 9
- 11

7
- 10,5
10,5 - 15,5
14
- 19

U12/16A 6 K1
U12/16A 9 K1
U12/16A 11 K1

1
1
1

0,10
0,10
0,10

10

- 14

18

U12/16A 14 K1

0,10

- 24

auto reset
or manual reset

With Quick Tripping Characteristic for EEx e motors and submersible pumps, f. contactors K1-..

102

0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U12/16EQ 0,6 K1
U12/16EQ 0,9 K1
U12/16EQ 1,2 K1

1
1
1

0,10
0,10
0,10

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U12/16EQ 1,8 K1
U12/16EQ 2,7 K1
U12/16EQ 4 K1

1
1
1

0,10
0,10
0,10

4
6
8

- 6
- 9
- 11

7
- 10,5
10,5 - 15,5
14
- 19

U12/16EQ 6 K1
U12/16EQ 9 K1
U12/16EQ 11 K1

1
1
1

0,10
0,10
0,10

10

- 14

18

U12/16EQ 14 K1

0,10

- 24

D677E

manual reset

Thermal Overload Relays for plug-in mounting


Setting Range
D.O.L. (A)

Type
(A)

Pack Weight
pcs. kg/pc.

Wiring Diagram

With Manual Reset, for contactors K(G)3-10.. to K(G)3-22.. ..


0,12 - 0,18
0,18 - 0,27
0,27 - 0,4

U12/16E 0,18 K3
U12/16E 0,27 K3
U12/16E 0,4 K3

1
1
1

0,10
0,10
0,10

0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U12/16E 0,6 K3
U12/16E 0,9 K3
U12/16E 1,2 K3

1
1
1

0,10
0,10
0,10

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U12/16E 1,8 K3
U12/16E 2,7 K3
U12/16E 4 K3

1
1
1

0,10
0,10
0,10

4
6
8

- 6
- 9
- 11

7
- 10,5
10,5 - 15,5
14
- 19

U12/16E 6 K3
U12/16E 9 K3
U12/16E 11 K3

1
1
1

0,10
0,10
0,10

10
13
17

- 14
- 18
- 23

18
23
30

- 24
- 31
- 40

U12/16E 14 K3
U12/16E 18 K3
U12/16E 23 K3

1
1
1

0,10
0,10
0,10

22

- 30

38

- 52

U12/16E 30 K3

0,13

manual reset

Mit flinker Auslsecharakteristik fr EEx e Motoren und Unterwasserpumpen


0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U12/16EQ 0,6 K3
U12/16EQ 0,9 K3
U12/16EQ 1,2 K3

1
1
1

0,10
0,10
0,10

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U12/16EQ 1,8 K3
U12/16EQ 2,7 K3
U12/16EQ 4 K3

1
1
1

0,10
0,10
0,10

4
6
8

- 6
- 9
- 11

7
- 10,5
10,5 - 15,5
14
- 19

U12/16EQ 6 K3
U12/16EQ 9 K3
U12/16EQ 11 K3

1
1
1

0,10
0,10
0,10

10

- 14

18

U12/16EQ 14 K3

0,10

- 24

manual reset

For contactors K(G)3-10.. to K(G)3-40A..


0,12 - 0,18
0,18 - 0,27
0,27 - 0,4

U3/32 0,18
U3/32 0,27
U3/32 0,4

1
1
1

0,14
0,14
0,14

0,4 - 0,6
0,6 - 0,9
0,8 - 1,2

U3/32 0,6
U3/32 0,9
U3/32 1,2

1
1
1

0,14
0,14
0,14

1,2 - 1,8
1,8 - 2,7
2,7 - 4

U3/32 1,8
U3/32 2,7
U3/32 4

1
1
1

0,14
0,14
0,14

4
6
8

- 6
- 9
- 11

7
- 10,5
10,5 - 15,5
14
- 19

U3/32 6
U3/32 9
U3/32 11

1
1
1

0,14
0,14
0,14

10
13
17

- 14
- 18
- 24

18
23
30

- 24
- 31
- 41

U3/32 14
U3/32 18
U3/32 24

1
1
1

0,14
0,14
0,14

23

- 32

40

- 55

U3/32 32

0,14

manual and
auto reset

For contactors K(G)3-24A.. to K(G)3-40A ..

D677E

10
14

- 14
- 20

18
24

- 24
- 35

U3/42 14
U3/42 20

1
1

0,30
0,30

20
28

- 28
- 42

35
48

- 48
- 73

U3/42 28
U3/42 42

1
1

0,30
0,30

manual and
auto reset

103

Thermal Overload Relays for plug-in mounting


Setting Range
D.O.L. (A)

Type
(A)

Pack Weight
pcs. kg/pc.

Wiring Diagram

For contactors K3-50A.. to K3-74A..


20
28
40

- 28
- 42
- 52

35
48
70

- 48
- 73
- 90

U3/74 28
U3/74 42
U3/74 52

1
1
1

0,40
0,40
0,40

52
60

- 65
- 74

90
104

- 112
- 128

U3/74 65
U3/74 74

1
1

0,40
0,40
manual and
auto reset

Thermal Overload Relays for separate mounting


Setting Range
D.O.L. (A)

Type
(A)

Pack Weight
pcs. kg/pc.

Wiring Diagram

For contactors K3-90, K3-115, K85, K110


60
80

- 90
-120
120

104
140

- 156
- 207

U85 90
U85 120

0,90
manual reset

For contactors K3-151.. and K3-176.., busbars included


120 - 180

208 - 312

U180 180

1,5

manual and
auto reset

For contactors K3-210.. up to K3-316.., busbars included


144 - 216
216 - 320

250 - 374
374 - 554

U320 216
U320 320

1,8

For contactors K3-315.. , K3-450.. , K3-550.. , K3-700.. , K3-860..


240 - 360
360 - 540

416 - 623
623 - 935

U800 360
U800 540

1
1

4,1
4,1

540 - 800

935 - 1385

U800 800

4,1

With Slow Tripping Characteristic for heavy duty starting with long run up times
For separate mounting, suitable for all contactors

104

0,8 - 1,2
1,2 - 1,8
1,6 - 2,4

1,2 2,1 2,8 -

2,1
3,1
4,2

UAT21 1,2
UAT21 1,8
UAT21 2,4

1
1
1

1,0
1,0
1,0

2,4 - 3,7
3,7 - 5,7
5,3 - 8,2

4,2 - 6,4
6,4 - 9,9
9,2 - 14,2

UAT21 3,7
UAT21 5,7
UAT21 8,2

1
1
1

1,0
1,0
1,0

8
12

- 12
- 18

13,9 - 20,1
20,1 - 31,2

UAT21 12
UAT21 18

1
1

1,0
1,0

16

- 24

27,7 - 41,6

UAT22 24

1,1

24
32
48

- 37
- 49
- 72

41,6 - 64
55,4 - 85
83
- 125

UAT23 37
UAT23 49
UAT23 72

1
1
1

1,3
1,3
1,3

D677E

manual reset

Accessories
for overload relays

Type

for contactors

Pack Weight
set
kg/set

Busbar Sets
SU840/550
SU840/860

U800
U800

K3-450.. , K3-550..
K3-700.. , K3-860..

for overload relay

Cable Cross-section (mm2) Type


solid or
stranded
flexible

1,7
2,1

Pack Weight
pcs. kg/pc.

Set for Single Mounting on DIN-rail with terminals


U12/16..K3

0,75 - 6

0,75 - 4

U12SM K3

0,035

U3/32SM

0,035

U3/42G

0,030

1
1

0,060
0,100

Additional Terminals with fingertouch protection


U3/32

0,75 - 6

0,75 - 4

Set for Single Mounting on DIN-rail


U3/42, U3/74

Connecting Wire Set for U3/42, U3/74 with Single Mounting


U3/42, U3/74
U3/42, U3/74

150mm lang 10mm2


250mm lang 10mm2

LG5830-4
LG5830-2

Additional Terminals with fingertouch protection


1-pole f. U12/16, U3/32 0,75 - 10

0,75 - 6

LG9339

0,009

3-pole for U3/42

6 - 25

LG7559

0,052

D677E

4 - 35

105

Thermal Overload Relays


Relays, tripping times for selection to motors of protection degree EEx e
Relays With Standard Tripping Characteristic

Setting Range

Tripping time depending on the multiple


of the current setting from cold condition
(tolerance 20% of the tripping time)

IA/I N
3

U3/32 ..

Relays With Quick Tripping Characteristic


preferably for motors with short tE time
and for submersible pumps

IA/I N
4

IA/IN
5

IA/I N
6

IA/IN
7,2

Setting Range

IA/IN
8

Tripping time depending on the multiple


of the current setting from cold condition
(tolerance 20% of the tripping time)
IA/IN
3

U12/16EQ ..

IA/I N
4

IA/I N
5

IA/I N
6

IA/IN
7,2

IA/IN
8

0,12
0,18
0,27
0,4

0,18
0,27
0,4
0,6

16,1
16,6
19,4
18,7

9,6
9,7
11,4
10,9

6,8
6,7
7,9
7,6

5,3
5,2
6,1
5,9

4,2
4,1
4,7
4,6

3,7
3,6
4,2
4,0

0,4
0,6
0,8
1,2

0,6
0,9
1,2
1,8

13,6
13,8
13,1
14,6

8,4
7,8
7,5
8,7

5,9
5,2
5,2
6,0

4,2
4,1
3,9
4,6

3,3
3,2
3,1
3,6

3,0
2,7
2,7
3,2

0,6
0,8
1,2
1,8

0,9
1,2
1,8
2,7

19,2
20,8
25,5
26,6

11,2
12,3
14,1
15,6

7,7
8,5
9,8
10,9

5,9
6,6
7,6
8,3

4,6
5,2
5,9
6,5

4,1
4,6
5,2
5,7

1,8
2,7
4
6

2,7
4
6
9

13,5
11,0
9,6
10,2

7,6
6,0
5,3
5,4

5,3
4,1
3,3
3,4

3,9
2,6
2,3
2,3

3,1
1,7
1,6
1,6

2,7
1,4
1,3
1,3

2,7
4
6
8

- 4
- 6
- 9
- 11

22,7
22,2
20,4
20,9

13,6
13,3
11,9
11,8

9,5
9,3
8,2
7,9

7,4
7,1
6,1
5,7

5,8
5,6
4,7
4,3

5,1
4,9
4,0
3,5

12,0
12,8

6,2
6,6

3,9
4,0

2,5
2,6

1,8
1,8

1,3
1,4

14
18
24
32

21,3
21,2
20,4
20,2

11,7
12,1
12,0
10,2

7,4
8,0
8,6
6,7

5,1
6,2
6,3
4,7

3,7
4,6
4,5
3,4

3,0
4,1
3,7
2,8

11,4
11,2
10,8
13,3

7,0
6,7
6,5
8,0

5,0
4,5
4,5
5,5

3,7
3,2
3,3
4,0

2,8
2,4
2,5
3,1

10
13
17
23

U3/42
10
14
20
28

14
20
28
42

21,8
22,4
21,8
25,2
s

28
42
52
65

21,8
25,2
18,3
17,8

10,8
13,3
9,2
8,7

s
- 90
- 120

19,5
18,0
s

360
480
620
800

23,3
23,0
20,5
21,0

14,1
13,8
12,4
12,5

10,0
9,6
9,0
9,0

U3/74
20
28
40
52
U85 ..
60
80
U840 ..
260
340
440
560

U12/16E(A) ..

6,5
8,0
5,6
5,2

4,5
5,5
3,9
3,4

3,3
4,0
2,8
2,5

2,5
3,1
2,2
1,9

13,5
11,0

11,0
10,0

10,0
9,0

9,5
8,5

8,5
8,0

7,6
7,6
7,0
7,0

6,1
6,1
5,5
5,6

5,4
5,4
5,0
5,2

0,12
0,18
0,27
0,4

0,18
0,27
0,4
0,6

18,5
16,7
19,4
18,7

10,4
9,8
12,1
11,2

7,2
6,5
8,2
8,0

5,5
5,0
5,9
6,0

4,3
4,1
4,9
4,9

3,6
3,5
4,2
4,1

0,6
0,8
1,2
1,8

0,9
1,2
1,8
2,7

19,7
22,9
22,2
23,0

11,6
13,6
13,2
13,7

8,1
10,0
9,2
9,3

6,1
7,3
7,6
7,6

4,9
6,0
5,8
5,7

4,2
5,2
5,3
5,1

2,7
4
6
8

- 4
- 6
- 9
- 11

24,0
24,7
22,0
17,4

14,4
13,8
13,4
9,2

9,9
9,9
8
5,9

7,8
7,3
5,7
4,1

5,9
5,6
4,1
2,9

5,1
4,8
3,5
2,3

14
18
23
30

26,4
14,7
16,2
16,8

12,9
7,7
8,4
8,5

7,6
4,8
5,0
5,0

5,2
3,2
3,6
3,6

3,5
2,3
2,4
2,3

2,8
1,7
1,8
1,9

10
13
17
22

106

8
10

- 11
- 14

All tripping times of overload relays U12/16EQ are shorter than the
minimum values of the tE time for motors of protection degree EEx e acc.
to EN 50019 and therefore are suitable for all motors of protection
degree EEx e. For these overload relays the selection on basis of
tripping curves is thereby not necessary.
When selecting a standard overload, refer to the tripping curve. Determine
the values of the starting current ratio IA/IN and the time tE which is marked
on the label of the motor. The overload must trip within the tE time, which
means that the tripping curve from cold condition must be (20% due to
tolerance) below the co-ordination point IA/IN and the time tE.
I N = Rated current of motor
I A = Starting current of motor
t E = tE-time of motor
Time tE /Tripping time
s
Typical tripping
curve for overload
relay U12/16E
Minimum values of
tE time (motor)
acc. to EN50019
Typical tripping
curve for overload
relay U12/16EQ
ratio IA/IN
Labels of tripping curves for each setting range, sized 148x105mm
(self-adhesive) are available on request.
Order No. D588, specify type and setting range.
Example of selection for thermal overload relay:
Technical data of a motor protection EEx e
PN= 1,5kW IN = 3,6A IA/IN = 5 tE time = 8s
1) U12/16E 4 (2,7 - 4A)
Tripping time at 5 x IN = 9,9s
9,9s + 20% tolerance = 11,9s > tE Motor = 8s
The device U12/16E 4 is not suitable
suitable.
2) U12/16EQ 4 (2,7 - 4A)
Tripping time at 5 x IN = 4,1s
4,1s + 20% tolerance = 4,9s < tE Motor = 8s
The device U12/16EQ 4 is therefore suitable
for motor protection
D677E

Thermal Overload Relays


Fuses for U3/32, U3/42, U3/74, U12/16E, U85, U180, U320 and U800
Type

DOL

U3/32
(U12/16E)

SCCR

kA

0,5 2)
1,0 2)
2

0,5 2)
1,0 2)
2

25
25
25

15
15
15

5
5
5

0,4 0,6 0,8 -

0,6
0,9
1,2

2
4
4

2
4
4

25
25
25

15
15
15

5
5
5

1,2 1,8 2,7 -

1,8
2,7
4

6
10
16

6
10
10

25
25
25

2
4
4

15
15
15

5
5
5

- 6
- 9
- 11

7 - 10,5
10,5 - 15,5
14 - 19

20
35
35

16
25
25

25
35
35

6
10
16

15
25
30

5
5
5

- 14
- 18
(23)24
-(23)24

18
23
30

- 24
- 31
-(40)41

50
50
63

35
35
50

63
63
63

16
20
25

40
50
60

5
5
5

-(30)32
(30)32 (38)40

-(52)55

80

63

80

35

70

10
14

- 14
- 20

18
24

- 24
- 35

50
63

35
50

80
80

16
25

40
60

5
5

20
28

- 28
- 42

35
48

- 48
- 73

80
100

63
80

80
150

35
50

80
110

5
5

20
28

- 28
- 42

35
48

- 48
- 73

100
125

80
100

150
150

35
50

80
110

5
5

40
52
60

- 52
- 65
- 74

70
90
104

- 90
- 112
- 128

160
160
160

100
125
125

150
150
150

63
80
80

200
250
250

5
10
10

60
80

- 90
-120
120

104
140

- 156
- 207

300
-

10
10

(22)23

U85

Fuse UL

0,18
0,27
0,4

10
13
17

U3/74

Max. Fuse Size According to Coordination-type


"2" 1)
"1" 1)
quick slow, gL(gG)
slow, gL(gG)
aM
A
A
A
A

0,12 0,18 0,27 -

4
6
8

U3/42

Setting Range

U180, U320
U800

all ranges
all ranges

For short circuit protecting overload relays with


current transformer use fuse according to the
contactor of the combination.

Tripping Characteristics for U3/32, U3/42, U3/74 and U12/16E


Detailed tripping times for each range see table page 106

with three-phase load

with two-pole load

Tripping time
min. s

Tripping time
min. s

Proceeding from service condition the times decrease


to 70-80% of the characteristic values

(Typical tolerance curve


from cold condition)

Proceeding from service condition the times


decrease to 20-30% of the characteristic values

(Average value of typical tolerance curves


from cold condition)

F. L. C. multiplication factor
1) Coordination-type according to IEC 947-4-1:
"2": Light contact welding accepted. Thermal overload relay must not be damaged.
"1": Welding of contactor and damage of the thermal overload relay allowed.
2) Miniature fuse

D677E

K =Imax /Ie

Imax = max. phase current


Ie
= max. scale value

3) Suitable for use on a capability of delivering not more than

107

Thermal Overload Relays


Tripping Characteristics for U85, U180, U320, and U800
Detailed tripping times for each range of U85 see table page 106

Tripping time (Average value of typical tolerance


min. s
curves from cold condition)

Tripping time (Average value of typical tolerance


min. s
curves from cold condition)

Tripping time (Average value of typical tolerance


min. s
curves from cold condition)

F. L. C. multiplication factor

F. L. C. multiplication factor

Proceeding from service condition the times


decrease to 20-30% of the characteristic values

U800 with three-phase load

Proceeding from service condition the times


decrease to 20-30% of the characteristic values

U180, U320 with three-phase load

Proceeding from service condition the times


decrease to 20-30% of the characteristic values

U85 with three-phase load

F. L. C. multiplication factor

U85 with two-pole load

Proceeding from service condition the times decrease


to 70-80% of the characteristic values

Tripping time (Typical tolerance curve


min. s
from cold condition)

K =Imax / Ie

Imax = max. phase current


Ie
= max. scale value

Position of Terminals
U3/32

108

U12/16E, U12/16EM, U12/16EQ

U12/16A

U3/42, U3/74

D677E

Thermal Overload Relays in Special Version


Fuse for U12/16EQ

Fuse for U12/16EM

Setting Range

Setting Range

Maximum Fuse Acc. to Coordination-type


"2" 1)
"1" 1)
quick
slow, gL(gG)
slow, gL(gG)
A
A
A

Maximum Fuse Acc. to Coordination-type "2" 1)


380-400V
500V
660-690V
slow, gL(gG)
slow, gL(gG)
slow, gL(gG)
A
A
A

0,6
0,9
1,2

2
4
4

2
4
4

25
25
25

0,12 0,18 0,27 -

0,18
0,27
0,4

none
none
none

none
none
none

on request
on request
on request

1,2 1,8 2,7 -

1,8
2,7
4

6
10
16

6
10
10

25
25
25

0,4 0,6 0,8 -

0,6
0,9
1,2

none
none
none

none
none
10

on request
on request
on request

1,2 1,8 2,7 -

1,8
2,7
4

none
20
35

16
20
35

on request
on request
on request

4
6
8

- 6
- 9
- 11

20
35
35

16
25
25

25
35
35

10

- 14

50

35

63

Tripping Characteristic for U12/16EQ

Tripping Characteristic for U12/16EM

with three-phase load

with three-phase load

range 0,4-0,6 to 1,8-2,7A

Tripping time
min. s

Detailed tripping times for each range see table page 106

(Typical tolerance curve


from cold condition)
Proceeding from service condition the times decrease
to 20-30% of the characteristic values

Tripping time
min. s

(Average value of typical tolerance


curves from cold condition)

Proceeding from service condition the times decrease


to 20-30% of the characteristic values

0,4 0,6 0,8 -

Lower scale value


Upper scale value
F. L. C. multiplication factor

F. L. C. multiplication factor

Fuse for UAT21, UAT22, UAT23

range 2,7-4 to 10-14A


(Typical tolerance curve
from cold condition)
Proceeding from service condition the times decrease
to 20-30% of the characteristic values

Tripping time
min. s

For short circuit protecting thermal overload relays with current


transformer use fuse according to the contactor of the combination.

Tripping characteristic for UAT21, UAT22, UAT23


with three-phase load
Tripping time in s

(Typical tolerance curve from cold condition)

Proceeding from service


condition the times decrease
to 20-30% of the
characteristic values

F. L. C. multiplication factor

F. L. C. multiplication factor
1) Coordination-type according to IEC 947-4-1:
"2": Light contact welding accepted. Thermal overload relay must not be damaged.
"1": Welding of contactor and damage of the thermal overload relay allowed.

D677E

109

Thermal Overload Relays


Data according to IEC 947-4-1, IEC 947-5-1, VDE 0660, EN 60947-4-1, EN 60947-5-1
Type

U3/32

U12/16 6)

V~
Permissible ambient temperature
operation
open C
storage
C

690

690

Trip class according to IEC 947-4-1


947-4-110A

10A

Rated insulation voltage Ui

U3/42 U3/74 U85 U180 U320


690

690

750

10A

10A

auxiliary connector

solid mm
flexible mm
flexible with multicore cable end mm
Cables per clamp
number
Type

U12/16A

V~
V~

690
440

690
-

690
440

A
A
A
A

3
2
1
0,5

4
2,5
1,5
0,6

24V A
110V A
220V A

1
0,15
0,1

Short circuit prot. (without welding 1kA)


highest fuse rating
gL (gG) A

Utilization category DC13


Rated operational
current Ie

UAT21 UAT22 UAT23

24V
230V
400V
690V

Type
Setting range
Power loss per current path (max.)
minimum setting value
maximum setting value

W
W

1000

690

-25 to +55
-40 to +70
10A

20

10A

3)

7)

10A
-

30

7)

690

30

30

0,5-10 0,5-16 0,5-25


0,5-6 0,5-10 0,5-16
0,5-6 0,5-10 0,5-16
1
1
1

1-2,52)
1-2,5 2)
1-2,5 2)
2

U12/16E U12/16EQ
U12/16EM

690
-25 to +60
-50 to +70

10

0,75-2,5 2)
0,5-2,5 2)
0,5-1,5
2
U3/32

Auxiliary contacts
Rated insulation voltage Ui 1)
same potential
different potential

690 1000

-25 to +60
-50 to +70

Cable cross-section
main connector
solid or stranded mm 0,75-6 0,75-6+0,75-2,5 2) 0,75-10 4-35 2)
flexible mm
1-4 0,75-4+0,5-2,5 2 ) 0,75-6 6-25 2)
flexible with multicore cable end mm 0,75-4 0,5-2,5+0,5-1,5 0,75-6 4-25
Cables per clamp
number
2
1+1
2
1

Utilization category AC15


Rated operational
current Ie

U800

1)

0,75-2,5 2)
0,5-2,5 2)
0,5-1,5
2

U3/42
U3/74

U85

U180
U320

U800

UAT21
UAT22
UAT23

690
440

690
250

690
440

690
440

500
500

690
440

5
3
2
0,6

5
3
2
0,6

4
2,5
1,5
0,6

5
3
2
0,6

3
2
1
0,5

4 5)
2,5
1,5
0,6

5
3
2
0,6

1,2
0,15
0,1

1,2
0,15
0,1

1,2
0,15
0,1

1,2
0,15
0,1

1,2
0,15
0,1

1,2
0,15
0,1

1,2
0,15
0,1

1,2
0,15
0,1

U3/32
all

U12/16
to 23A

U12/16E
22 - 30A

U3/42
to 28A

U3/42
28 - 42A

U3/74
to 52A

U3/74
52 - 65A

U85
all

1,1
2,3

1,1
2,3

1,7
3,7

1,3
2,6

1,3
3,3

2,0
3,7

2,9
4,5

1,1
2,5

Data according to cULus


Type

U3/32

U12/16A

U12/16E

U12/16EQ

U3/42

U3/74

U85

Rated insulation voltage


Rated current

V~
A

600
32

600
23

600
23

600
23

600
42

600
74

600
85

Auxiliary contacts
Rated voltage
same potential
different potential

V AC
V~

600
150

600
-

600
150

600
150

600
150

600
150

600
150

Switching capacity AC
of aux. contacts

VA
A

500
2

500
3

500
4

500
4

600
4

600
4

600
4

Temperature Compensation
In case of higher ambient temperature use the following formula:
(Ambient temperature - 20) x 0,125 = correction factor in %
of the
full load motor current

Example: Ambient temperature 70C, full load motor current 7A


(70 - 20) x 0,125 = 6,25%
Setting value: 7A + 6,25% = 7,44A

1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV (at 440V), 6kV (at 690V).
Data for other conditions on request.
2) Maximum cable cross-section with prepared conductor
3) Without terminals, suitable for bushing one connector 70mm (stranded) per phase
4) Switching capacity of the start contact: AC15 300VA, max. 1,5A, DC13 (max. 220V) 30W, max. 1,5A
5) Switching capacity of the make contact: AC15 400VA, max. 1,7A, DC13 (max. 220V) 10W, max. 1A
6) U12/16E 30: Cable cross-section for main connector like type U3/42, one connector only
7) Busbar sets see accessories page 103

110

D677E

Thermal Overload Relays


Dimensions
K3-10N + U3/32
K3-14N
K3-18N
K3-22N

KG3-10 + U3/32
KG3-14
KG3-18
KG3-22

K3-24 + U3/32
K3-32
K3-40

KG3-24 + U3/32
KG3-32
KG3-40

K3-24 + U3/42
K3-32
K3-40

KG3-24 + U3/42
KG3-32
KG3-40

U3/32SM

U3/42G +LG5830-.

D677E

Changing of connecting wire with 1,8Nm

111

Thermal Overload Relays


Dimensions
K1-09 + U12/16.. K1
K1-12

K3-10 + U12/16..K3
K3-14
K3-18
K3-22

K3-10N + U12/16..K3
K3-14N
K3-18N
K3-22N

KG3-10 + U12/16..K3
KG3-14
KG3-18
KG3-22

U12SM K3
U12/16..K3 + U12SM K3 for snap-on 35mm DIN-rail according to
DIN EN50022 and screw mounting (single mounting)

K3-50 + U3/74
K3-62
K3-74

112

D677E

Thermal Overload Relays


Dimensions
K3-90A + U85
K3-115A

K3-151A00 + U180
K3-176A00

Bohrplan

K3-210A00 + U320
K3-260A00
K3-316A00

Bohrplan

D677E

113

Thermal Overload Relays


Dimensions
U800

U800 with

K3-450
K3-550

220 372 110 220 158


220 395 110 220 158

40 185 225
40 196 225

12,5
12,5

9
9

K3-700
K3-860

280 487 175 280 202


280 540 175 280 202

50 257 291
50 280 291

14,5
14,5

11
11

UAT21

UAT22

UAT23
Type

Setting Range

UAT23 37
UAT23 49
UAT23 72

23-37A
32-49A
48-72A

114

105,5
94
94

97,5
86
86

D677E

Modular Contactors

D677E

Modular Contactors

116

Auxiliary Contact Block


Accessories

117
117

Day-Night Reloading Contactors

118

Switching Of Lamps

118

Technical Data

120

Dimensions

122

115

Modular Contactors
Rated Heating Power
Current AC1 at
AC1
400V
A

Type

1-phase 3-phase
230V
400V
kW
kW

24
230
24VM
230VM

coil voltage
24V 50/60Hz
220-240V 50Hz, 230-264V 60Hz
24V 50/60Hz, 24V DC
220-240V 50/60Hz, 220V DC
Pack
Weight
pcs.
kg/pc.
Wiring Diagram

One-pole 1 module (17,5mm)


20
20

4,6
4,6

R20-10 24
R20-10 230

12
12

0,12
0,12

Two-pole 1 module (17,5mm)


20
20

4,6
4,6

R20-20 24
R20-20 230

12
12

0,12
0,12

20
20

4,6
4,6

R20-11 24
R20-11 230

12
12

0,12
0,12

20
20

4,6
4,6

R20-02 24
R20-02 230

12
12

0,12
0,12

25
25

5,5
5,5

R25-20 24
R25-20 230

12
12

0,14
0,14

25
25

5,5
5,5

R25-11 24
R25-11 230

12
12

0,14
0,14

25
25

5,5
5,5

R25-02 24
R25-02 230

12
12

0,14
0,14

Four-pole 2 modules (35mm) 1


25
25

5,7
5,7

17
17

R25-40 24
R25-40 230

6
6

0,21
0,21

25
25

5,7
5,7

17
17

R25-31 24
R25-31 230

6
6

0,21
0,21

25
25

5,7
5,7

17
17

R25-13 24
R25-13 230

6
6

0,21
0,21

25
25

5,7
5,7

R25-22 24
R25-22 230

6
6

0,21
0,21

25
25

5,7
5,7

17
17

R25-04 24
R25-04 230

6
6

0,21
0,21

Four-pole 2 modules(35mm), AC/DC-operated 1)


25
25

5,7
5,7

17
17

R25-40 24VM
R25-40 230VM

6
6

0,22
0,22

25
25

5,7
5,7

17
17

R25-31 24VM
R25-31 230VM

6
6

0,22
0,22

25
25

5,7
5,7

17
17

R25-13 24VM
R25-13 230VM

6
6

0,22
0,22

25
25

5,7
5,7

R25-22 24VM
R25-22 230VM

6
6

0,22
0,22

25
25

5,7
5,7

17
17

R25-04 24VM
R25-04 230VM

6
6

0,22
0,22

1) Sealable with Sealing Cover P721, available aux. contact block RH11(see page 117)
2) Sealable with Sealing Cover P721, available aux. contact block RH11-1(see page 117)
116

D677E

Modular Contactors
R a t e d Heating
Current AC1 at
AC1
1-phase
400V 230V
A
kW

Type

Power
3-phase
400V
kW

coil voltage
24V 50/60Hz
220-240V 50Hz, 230-264V 60Hz
Pack
Weight
pcs.
kg/pc.
Wiring Diagram

24
230

Two-pole 2 modules (35mm)


40
40

9
9

R40-20 24
R40-20 230

6
6

0,23
0,23

63
63

14,3
14,3

R63-20 24
R63-20 230

6
6

0,23
0,23

Four-pole 3 modules (52,5mm) 1)


40
40

9
9

27,5
27,5

R40-40 24
R40-40 230

4
4

0,35
0,35

40
40

9
9

27,5
27,5

R40-31 24
R40-31 230

4
4

0,35
0,35

40
40

9
9

R40-22 24
R40-22 230

4
4

0,35
0,35

40
40

9
9

27,5
27,5

R40-04 24
R40-04 230

4
4

0,35
0,35

63
63

14,3
14,3

43
43

R63-40 24
R63-40 230

4
4

0,36
0,36

63
63

14,3
14,3

43
43

R63-31 24
R63-31 230

4
4

0,36
0,36

63
63

14,3
14,3

R63-22 24
R63-22 230

4
4

0,36
0,36

63
63

14,3
14,3

43
43

R63-04 24
R63-04 230

4
4

0,36
0,36

Auxiliary Contact Block module (8,8mm) for contactor R25 (4p.), R40, R63 (max. 1pc.)
Rated
AC15
230V
A

current
AC15 AC1
400V 690V
A
A

Type
for contactor
2),

10

R25

10

R25-..VM
VM

R40, R63

Accessories

Pack
pcs.

kg/pc.

RH11

0,026

RH11-1

0,026

Pack
pcs.

Weight
kg/pc.

Type
RC-unit
2x for R20.. to R63..
for 12V to 250V AC
220nF / 100 Ohm
not for R25-..VM

RC-R 230

Spacing piece module (8,8mm)


for R20.. to R63..
for ambient temperature >40C

0,05

P730

10

0,012

P721
P690

10
10

0,002
0,003

Weight
Wiring Diagram

40C

40 - 60C

Sealing cover for R25.. (4p.)


Sealing cover for R40.., R63..

1) Sealable with Sealing Cover P690, available aux. contact block RH11
2) AC-operated R25-.., 4-pole
D677E

117

Day-Night Reloading Contactors


Type

Pack
pcs.

Weight
kg/pc.

R25-TN 230

0,22

Wiring Diagram

Compact Module, for separate tarif counters 2 modules (35mm)


3-pole 400V 25A

2 Switch positions:
Day (Reloading, contact 11-14 ... closed, remains in position Night, until the next occurs)
Night (Basis operation) contact 11-12 ... closed

Contactor Module, for double tarif counters 1 module (17,5mm)


2-pole 400V 25A

R25-TN20 230

0,13

4 Switch position:
Day (Reloading, contact 1-2 ... closed, remains in position Night, until the next occurs)
Night (automatic operation, contact 1-2 ... only at night closed)
On (Permanently On)
Off (permanently Off)

Switch Module 1 module (17,5mm)


2-pole 400V 25A

RH25-20

0,13

Modular Contactors
Switching of lamps
Lamp Type
Incandescent lamps

Fluorescent lamps
uncompensated or
serial compensated

Fluorescent lamps
dual-connection

Fluorescent lamps
parallel compensated

118

Power
W

Current
A

Capacitors
F

Max. lamps per pole at 230V 50Hz and max. 60C


R25..
R40..
R63..
R20..

60
100
200

0,27
0,45
0,91

22
13
10

50
30
15

92
55
27

129
77
38

300
500
1000

1,36
2,27
4,5

4
3
1

10
6
3

19
11
6

26
16
8

11
18
24

0,16
0,37
0,35

1,3
2,7
2,5

60
25
25

75
30
30

210
90
90

310
140
140

36
58
65
85

0,43
0,67
0,67
0,8

3,4
5,3
5,3
5,3

20
14
13
11

25
17
16
14

70
45
40
35

140
70
65
60

11
18
24

0,07
0,11
0,14

2 x 100
2 x 50
2 x 40

2 x 110
2 x 55
2 x 44

2 x 220
2 x 130
2 x 110

2 x 250
2 x 200
2 x 160

36
58
65
85

0,22
0,35
0,35
0,47

2 x 30
2 x 20
2 x 15
2 x 10

2 x 33
2 x 22
2 x 16
2 x 11

2 x 70
2 x 45
2 x 40
2 x 30

2 x 100
2 x 70
2 x 60
2 x 40

11
18
24

0,09
0,13
0,16

2,0
2
3

30
20
15

43
32
32

67
50
50

107
80
80

36
58
65
85

0,27
0,45
0,5
0,6

4
7
7
8

10
6
5
4

32
18
18
16

50
36
36
33

80
46
46
44
D677E

Modular Contactors
Switching of lamps
Lamp Type

Power
W

Fluorescent lamps
with electronic fluorescent
lamp ballast
2
2
2
2
2

Mercury-vapour lamps
(high-pressure lamps),
compensated
e. g. HQL, HPL

Metal halide lamps


uncompensated
e. g. HQI, HPI, CDM

400V per pole


Metal halide lamps
compensated
e. g. HQI, HPI, CDM

Metal halide lamps


with electronic fluorescent
with electronic fluorescent
lamp ballast (e. g.: PCI)
50-125 x In lamp for 0,6ms

Max. lamps per pole at 230V 50Hz and max. 60C


R20..
R25..
R40..
R63..

0,09
0,16
0,25
0,4

40
20
15
7

40
20
15
10

100
52
30
20

150
75
55
30

18
28
36
58
80

0,17
0,25
0,32
0,49
0,7

20
15
10
7
4

20
15
10
7
4

50
37
25
15
8

60
45
30
20
10

20
50
75

0,09
0,22
0,33

40
20
13

52
24
16

110
50
35

174
80
54

100
150
200
300

0,43
0,65
0,87
1,30

10
7
5
3

12
9
5
4

27
19
14
9

43
29
23
14

50
80
125

0,61
0,8
1,15

16
12
8

21
16
11

38
29
20

55
40
28

250
400
700
1000

2,15
3,25
5,4
7,5

4
3
1
1

6
4
2
1

11
7
4
3

15
10
6
4

50
80
125

0,28
0,41
0,65

7
8
10

7
5
3

18
16
13

36
31
25

50
44
35

250
400
700
1000

1,22
1,95
3,45
4,8

18
25
45
60

2
1
1
-

7
5
3
2

14
10
6
4

19
14
8
6

35
70
150

0,53
1
1,8

22
12
6

24
14
8

57
30
17

65
35
18

x
x
x
x
x

250
400
1000
2000

3
3,5
9,5
16,5

4
3
1
-

5
4
1
-

10
8
3
2

12
10
4
2

2000
3500

10,5
18

2
1

2
1

6
12
20

8
4
2

21
11
7

42
21
13

58
29
18

35
70
150

400V per pole

Capacitors
F

18
36
58
80

Transformers
for metal halid
low voltage lamps

Mercury-vapour lamps
(high-pressure lamps),
uncompensated
e. g. HQL, HPL

Current
A

0,25
0,45
0,75

250
400
1000
2000

1,5
2,1
5,8
11,5

33
35
95
148

1
1
-

4
4
1
-

9
9
3
2

11
10
4
2

2000
3500

6,6
11,6

58
100

3
2

4
3

integrated
integriert
integrated
integrated
integrated

9
6
5
4

9
6
5
4

18
11
10
8

20
18
13
12
10

20
28
35
70
150

0,1
0,15
0,2
0,36
0,7

35
55
90

1,5
1,5
2,4

7
7
4

9
9
6

22
22
13

30
30
19

135
150
180
200

3,3
3,3
3,3
3,3

3
3
3
3

4
4
4
4

10
10
10
10

14
14
14
14

Sodium-vapour lamps
(low pressure lamps),
uncompensated

D677E

119

Modular Contactors
Switching of lamps
Lamp Type

Power
W

Sodium-vapour lamps
(low pressure lamps),
compensated

Sodium-vapour lamps
(high pressure lamps),
uncompensated

Sodium-vapour lamps
(high pressure lamps),
compensated

Sodium-vapour lamps
(high pressure lamps)
with serial electronic
(e. g.: PCI)
50-125 x Inlamp for 0,6ms

Current
A

Capacitors
F

Max. lamps per pole at 230V 50Hz and max. 60C


R25..
R40..
R63..
R20..

35
55
90

0,31
0,42
0,63

20
20
30

3
2
1

6
6
4

15
15
10

18
18
12

135
150
180
200

0,94
1
1,16
1,32

45
40
40
25

1
1
1
-

3
3
3
-

7
8
8
10

8
9
9
12

150
250
330

1,8
3
3,7

5
4
3

8
5
4

17
10
8

22
13
10

400
1000

4,7
10,3

2
1

3
1

6
3

8
4

150
250
330

0,83
1,5
2

20
33
40

2
1
1

7
4
3

20
12
10

25
15
13

400
1000

2,4
6,3

48
106

1
-

2
1

8
4

12
6

20
35
70
150

0,1
0,2
0,36
0,7

integrated
integrated
integrated
integrated

9
6
5
4

9
6
5
4

18
11
10
8

20
13
12
10

Data according to IEC60 947-4-1, IEC 60947-5-1, VDE 0660-5-1


2-pole
R20

R25

R40

R63

4-pole
R25

R40

R63

RH11

440 2)
440

440 2)
440

440 2)
440

440 2)
440

440 2)
440

440 2)
440

440 2)
440

440 2)
440

Frequency of operations zzAC1, AC3 1/h


Mechanical life
S x 106

300
1

300
1

600
1

600
1

300
1

600
1

600
1

600
1

Utilization category AC1


Rated operational current Ie (=Ith)
open
at 60C

20

25

40

63

25

40

63

0,1
24/100
72
3

0,1
24/100
72
3

0,1
24/100
216
7

0,1
24/100
240
2

0,1
24/100
72
3

0,1
24/100
216
7

0,1
24/100
240
0,5

17/5
-

27

30

Type
Main Contacts 5) 6) 7)
Rated insulation voltage U i
Rated operation voltage Ue

Contact life
Minimum Switch Voltage
Short time current
10s-current
Power loss per pole at Ie/AC1
W

V~
V~

A
106

Sx
V/mA
A
2

Utilization category AC3 / AC7b


Switching of three-phase motors
Rated operational current Ie
A
Rated operational power
of three-phase motors
50-60Hz

220V
230-240V
380-415V

kW
kW
kW

2,2
2,5
4

7,5
8
12,5

8
8,5
15

230V

kW

1,1

1,3

2,6

S x 106

0,15

0,15

0,15

0,15

0,15

0,15

0,15

7-9
2,2 - 4,2
0,8 - 1,6
-

7-9
2,2 - 4,2
0,8 - 1,6
-

5-7

5-7

33 - 45
6-8
2,6
-

33 - 45
6-8
2,6
-

Operation range of coils


in multiples of control voltage Us (-40--+40C) 0,85 - 1,1

0,85 - 1,1

0,85 - 1,1

0,85 - 1,1

0,85 - 1,1

0,85 - 1,1

2-pole motors
Contact life

Power consumption of coils


AC operated
inrush
sealed
AC and DC-operated

VA
VA
W
W

20
4
1,5
3

25
6
2,5
4

0,85 - 1,1

1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV.
2) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV.
3) Maximum cable cross-section with prepared conductor
5) Rated frequency 50/60Hz
6) Max. occ. switching overvoltage <4kV
7) Duty cycle: 100%

120

D677E

Modular Contactors
Data according to IEC60 947-4-1, IEC 60947-5-1, VDE 0660-5-1
Type

R20

R25 (2p.) R25 (4p.)

R25-..VM

R40

R63

RH11

Short circuit protection


max. fuse Coordination-type "1"gL (gG) A
Rated short circuit current
"r" kA
"Iq" kA

35
3
3

35
3
3

35
3
10

35
3
10

63
3
10

80
3
10

Switching time at control voltage Us 10%


make time ms
release time ms
arc duration ms

7 - 16
6 - 12
10 - 15

7 - 16
6 - 12
10 - 15

9 - 15
4-8
10 - 15

17 - 24
17 - 23
10 - 15

11 - 15
6 - 13
10 - 15

11 - 15
6 - 13
10 - 15

Cable cross-sections
Main connector
solid or stranded
flexible
flexible with multicore cable end
Clamps per pole

mm
mm
mm

1,5 - 10
1,5 - 6
1,5 - 6
1

1,5 - 10
1,5 - 6
1,5 - 6
1

1,5 - 10
1,5 - 6
1,5 - 6
1

1,5 - 10
1,5 - 6
1,5 - 6
1

2,5 - 25
2,5 - 16
2,5 - 16
1

2,5 - 25
2,5 - 16
2,5 - 16
1

0,5 - 2,5 3)
0,5 - 2,5 3)
0,5 - 1,5
2

mm
mm
mm

0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1

0,75 - 2,5
0,5 - 2,5
0,5 - 2,5
1

0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1

0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1

0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1

0,75 - 2,5
0,5 - 2,5
0,5 - 1,5
1

V AC
A
A

440 2)
10
6

220-240V
380-415V
440V

A
A
A

24-60V
110V
220V

A
A
A

Short circuit protection


short-circuit current 1kA,
contact welding not accepted
max. fuse size
gL (gG)

Magnetic coil

solid or stranded
flexible
flexible with multicore cable end
Clamps per pole
Auxiliary Contacts 5) 6) 7)
Rated insulation voltage Ui 1)
Thermal rated current Ith
Ambient temperature
Utilization category AC15
Rated operational
current Ie
Utilization category DC13
Rated operational
current Ie
per pole

40C
60C

3
2
1,6

2
0,4
0,1

10

Data according to UL508


Main Contacts (cULus)

Type

Rated operational current "General Use"

R20
20

25

25

1
2
3
3

Rated operational power of three-phase motors


at 60Hz (3ph)

110-120V
200-208V
220-240V
265-277V

hp
hp
hp
hp

Rated operational power of of AC motors


at 60Hz (1ph)

110-120V
200-208V
220-240V
265-277V

hp
hp
hp
hp

1
1
1

Fuses
Suitable for use on a capability of delivering not more than

rms

Rated operation voltage


Auxiliary Contacts (cULus)

heavy pilot duty

A
A
V

R25 (2p.) R25 (4p.)

1
1
2

1
1
2

R40

R63

RH11

40

63

10

2
5
7
7
1
2
3
3

3
7
10
10

1
3
5
5

40
5000
300

40
5000
300

40
5000
300

80
5000
300

80
5000
300

300

V~

300

300

300

300

300

300

AC

C300

2) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV.
3) Maximum cable cross-section with prepared conductor
4) AC7b motor 2-pole 230V 1,1kW
5) Rated frequency 50/60Hz
6) Max. occ. switching overvoltage <4kV
7) Duty cycle: 100%

D677E

121

Modular Contactors
Dimensions
R20-.., R25-.. (2-pole)
RC-R 230, RH25-20

R25-TN

R40-.. (2-pole)
R63-.. (2-pole)

R25-.. (4-pole) (+RH11)


R25-..VM
(+RH11-1)

R40-.. (4-pole) (+RH11)


R63-.. (4-pole) (+RH11)

Aux. contact block


RH11, RH11-1

European Representations and Suppliers


Belgium

+32

France

Teconex
Material Electrique
Rue de Magnee 108
B - 4610 Beyne-Heusay

Tel: 04 / 355 88 26
Fax: 04 / 358 21 97
[email protected]
www.teconex.eu

Teconex
Material Electrique
Rue de Magnee 108
B - 4610 Beyne-Heusay

Tel: 04 / 355 88 26
Fax: 04 / 358 21 97
[email protected]
www.teconex.eu

Bulgaria

+359

Germany

+49

Schrabul Ltd
Yordan Yovkov Str. 8
BG - 1408 Sofia

Tel: 02 / 958 76 54
Fax: 02 / 958 59 95
[email protected]

Cyprus

+357

Rudolf Kiesewetter
Tel: 0341 / 550 16 06
Messtechnik GmbH
Fax: 0341 / 550 16 09
Prager Strasse 34
[email protected]
D - 04317 Leipzig
www.kiesewetter-mt.de
Representation for Postleitzahlgebiet 0

M. Hadjioannou Ltd.
Electrotechnical & Lighting Specialists
Aegeos 8c, Pallouriotissa
CY - Nicosia

Tel: 22 / 348 262


Fax: 22 / 430 107
[email protected]

Denmark

+45

MTO electric a/s


Andkaervej 26
DK - 7100 Vejle

Tel: 075 / 800 310


Fax: 075 / 800 320
[email protected]
www.mto-electric.dk

Finland

+358

UTU Powel Oy
Palopellonkatu 7
PL 33
FIN - 04251 Kerava

Tel: 09 / 274 64 11
Fax: 09 / 274 64 141
[email protected]
www.urhotuominen.fi

122

+32

TVB GmbH
Tel: 040 / 608 750 22
Bro fr Elektroanlagen u. Gerte Fax: 040 / 608 750 23
Hartje Rterweg 88
[email protected]
D - 22399 Hamburg
www.tvb-hamburg.de
Representation for Postleitzahlgebiete 1, 2 and 3
Wagner GmbH
Tel: 02058 / 782 800-0
Werksvertretungen d. Elektroind.
Fax: 02104 / 752 800-49
Robert Bosch Strae 35
[email protected]
D - 42489 Wlfrath
www.wagnergmbh.de
Representation for Postleitzahlgebiete 4 and 5
Wilhelm Becker
Tel: 06175 / 798 194
Elektro-Handelsvertretung
Fax: 06175 / 798 195
Zum Kpperner Tal 17
[email protected]
D - 61381 Friedrichsdorf-Burgholzhausen www.becker-ehv.de
Representation for Postleitzahlgebiete 6 and 7
SBV - Gawehn GmbH
Tel: 09101 / 9099-0
Industrievertretungen
Fax: 09101 / 9099-30
Zollnerstrae 2
[email protected]
D - 90579 Langenzenn
Representation for Postleitzahlgebiete 8 and 9

D677E

European Representations and Suppliers


Great Britain

+44

Romania

+40

IMO Precision Controls Ltd.


1000 North Circular Road
GB - NW2 7JP London

Tel: 020 / 8452 6444


Fax: 020 / 8450 2274
[email protected]
www.imopc.com

Imsat International SA
Str. Episcop Radu nr. 15A
sect. 2, cod 72159
RO - 76548 Bukarest

Tel: 01 / 210 25 81
Fax: 01 / 210 30 35
[email protected]
www.imsatint.ro

Geyer Hellas s.a.


Electrical And Electronic Material
PO Box 19038
GR - 34100 Drosia-Chalkis

Tel: 22210 / 987 11


Fax: 22210 / 987 12
[email protected]
www.geyer.gr

Russia

+7

Hungaria

+36

Torgoviy Dom ChEAZ


ChEAZ Trading House LLC
16/1ul. Dokukina,
Moskau
RU-129226 Russia

Tel: 095 / 99 53 100


Fax: 095 / 99 53 200
[email protected]
www.cheaz.ru

Dial-Comp GmbH
Keszkeno u. 46/b.
H - 1131 Budapest

Tel: 01 / 236 0427


Fax: 01 / 236 0430
[email protected]
www.dialcomp.hu

DIAL Electrolux Ltd.


Bld. 1, Block2, Fl. 7
131
Deguninskaia St., Moscow
RU-127486 Russia

Tel: 495 / 48 73 350


Fax: 495 / 48 73 654 add.

Spain

+34

Cydesa
Construcciones y Distribuciones,
Elctricas, S.A.
C.Poligono Industriel Sant
Antoni Parcela 2 Nave A
E - 08620 Sant Vicenc Dels Horts
Barcelona

Tel: 93 / 656 59 50
Fax: 93 / 656 65 59
[email protected]
www.cydesa.com

Sweden

+46

Wallin & Co AB
Gtlundagatan 10
Box 420
S - 12404 Bandhagen

Tel: 8 / 860 102


Fax: 8 / 997 050
[email protected]
www.wallin-co.se

Switzerland

+41

Benedict Swiss AG
Grindelstrae 19
CH - 8303 Bassersdorf

Tel: 44 / 213 66 00
Fax: 44 / 213 66 09
[email protected]
www.benedict-swiss.ch

Serbia and Montenegro

+381

Elektro-K
oil d.o.o.
Elektro-Koil
Osjecka 4
SRJ-11000 Belgrad

Tel: 11 / 35 42 631
Fax: 11 / 35 71 911
www.elektrokoil.co.yu

Turkey

+90

Ergun Elektrik Co Ltd.


Kazim Dirik Mahallesi
Sanayi Caddesi No: 66
Bornova, Izmir
35100 TURKEY

Tel: 01 / 236 0427


Fax: 01 / 236 0430
[email protected]
www.ergunelektrik.com

Greece

+30

Italy

+39

SIF Trading
Via Per Curnasco 64
I - 24127 Bergamo

Tel: 035 / 258 853


Fax: 035 / 258 011
[email protected]

Netherlands

+31

Hirsch-Driebergen B.V
B.V..
Postbus 143
NL - 3970 AC Driebergen

Tel: 0343 / 515 534


Fax: 0343 / 520 314
[email protected]
www.hirsch-driebergen.nl

Norway

+47

Gylling T
eknikk AS
Teknikk
P. O. Box 103
Rudssletta 71
N - 1351 Rud

Tel: 67 / 15 14 00
Fax: 67 / 15 14 01
[email protected]
www.gylling.no

Poland

+48

ASTAT Sp. z o.o.


Ul. Dabrowskiego 441
PL - 60-451 Poznan

Tel: 61 / 848 88 71
Fax: 61 / 848 82 76
[email protected]
www.astat,com.pl

Automatech Sp. z o.o.


Ul. Ryzowa 84
PL - 05-816 Opacz-Kolonia

Tel: 22 / 723 06 62
Fax: 22 / 723 06 06
[email protected]
www.automatech.pl

Dukat Sp. z o.o.


Ul. 20 Stycznia 95/5
PL - 95-200 Pabianice

Tel: 422 / 152 571


Fax: 422 / 152 571
[email protected]
www.dukatad.pl

Portugal

+351

Jayme da Costa
Mecanica e Electricidade, S.A.
Rua de Murraceses, 216
P - 4416 - 901 Pedroso

Tel: 22 / 74 70 250
Fax: 22 / 76 40 548
[email protected]
www.jaymedacosta.pt

D677E

[email protected]
www.dialelectrolux.ru

123

Oversea Representations and Suppliers


Australia

+61

New Zealand

+64

BRIDEX-ETS PTY LTD


Unit 12
20 Narabang Way
NSW 2085 Berlose
AUS

Tel: 02 / 9986 17 11
Fax: 02 / 9986 17 66
[email protected]
www.bridex-ets.com.au

Eurotec Instruments Ltd.


P.O.Box 14-543 Panmure
750 Gt South Rd, Penrose
NZ - Auckland

Tel: 09 / 579 1990


Fax: 09 /499 36 96
[email protected]
www.eurotec.co.nz

Bolivia

+591

Singapore and Malaysia

+65

Agencias Generales S.A.


Casilla de Correo 530
Av. San Martin
BO - 0253 Cochabamba

Tel: 04 / 425 10 62
Fax: 04 / 425 10 61
[email protected]
www.agsa.com

Mecomb Singapore Ltd.


#04-02 Sime Darby Centre
896 Dunearn Road
SGP - 589472 Singapore

Tel: 646 98 833


Fax: 646 71 905
[email protected]

Canada

+1

South Africa

+27

Brook Crompton Ltd.


264 Attwell Drive
Toronto, ON
CDN - M9W 5B20 Ontario

Tel: 0416 / 675 38 44


Fax: 0416 / 675 68 85
[email protected]

Deebar
Mining & Ind. Supplies
P.O. Box 40325
RSA - 2022 Cleveland

Tel: 021 / 873 43 32


Fax: 021 / 825 69 84
[email protected]

Egypt

+20

Tel: 021 / 52 3023


Fax: 021 / 52 2704
[email protected]

Economic Co.
Electrical Commerce & Import
44, Naguib El-Rihani St.
ET - Kairo

Tel: 02 / 592 91 80
Fax: 02 / 590 78 82
[email protected]

Electric Assemblies
Unit 2A Simplex Ind. Park
Engine Road,
RSA - 7441 Cape Town

Syria

+963

Hong Kong

+852

Tel: 011 / 221 14 45


Fax: 011 / 221 67 45
[email protected]

Creation Building Services


Materials Limited
5st Floor, Hing Yip Centre
37 Beech Street, Tai Kok Tsui
HK-Kowloon
Hong Kong - China SAR

Tel: 2408 3333


Fax: 2191 5510
[email protected]
www.ysh.com.hk

T. S. Boyadjian
Electrical Equipments
Halbouni Street no. 9
P.O. Box 2822
SYR - Damaskus

Taiwan

+886

Iran

+98

Tel: 02 / 2643 6183


Fax: 02 / 8691 6288
[email protected]

Nader Pardaz Co.


Unit 12, 6 Floor, No.12,
Bahar Shiraz St.
Tehran-Iran

Tel: 21/77631517
Tel: 21-77509555
[email protected]
www.naderpardaz.ir

Vinmajor Enterprise Co., Ltd.


8F-2, No. 306, Section 1
Ta-Tung Road, Hsi-Chih
Taipei Hsien, Taiwan
R.O.C.

U.A.E.

+971

Israel

+972

Doepke International Trading LLC


Carrera Building - Karama
Suite 206, 2nd Floor
P.O.Box:48767 Dubai

Tel: 04 / 33 62 880
Fax: 04 / 33 62 890
[email protected]
www.doepke.de

Gino Industries Ltd.


3, Ophir Street
IL - 32235 Haifa

Tel: 03 / 687 92 66
Fax: 03 / 688 26 91
[email protected]
www.gino-ind.com

USA

+1

Kenya

+254

Tel: 919/553 5501


Fax: 919/553 5565

G.F. Corvin Ltd.


P.O. Box 30747
00100 Nairobi
EAK Kenia

Tel: 02 / 802 908


Fax: 02 / 802 956
[email protected]

B&J USA Inc.


120-101 North Tech Drive
Post Office Box 877
Clayton, N.C. 27528

Zimbabwe

+263

Mexico

+52

B&J USA Inc.


120-101 North Tech Drive
Post Office Box 877
Clayton, N.C. 27528

Tel: 919/553 5501


Fax: 919/553 5565
[email protected]
www.bnj-usa.com

Star Delta Electrix


Cnr 11th Ave and Fife Str.
P.O. Box 3592
ZW - Bulawayo

Tel: 9 / 715 24
Fax: 9 / 776 18
[email protected]

Star Delta Electrix


Graniteside Way, Harare
P.O. Box 2753
ZW - Harare

Tel: 4 / 754 792/8-28


Fax: 4 / 754 790
[email protected]

124

[email protected]
www.bnj-usa.com

D677E

Alphabetical Index
Description

Type

Page

A dditional Terminals for Contactors


for D.O.L. Starters
for Star-Delta Starters
for Thermal Overload Relays
Auxiliary Contact Blocks for Contactors K1-07
for Contactors K1-09, -12
for Contactors K3
for Contactors K3
for Contactors K3
for Contactors K3
for Contactors R..

LG..
LG..
LG..
LG..
HK..
HKM..
HA..
HB11
HN..
HK..
RH11

37
97
77
105
8
10, 14
22, 34
34
22, 34
34
117

Busbar Sets for Thermal Overload Relays

SU840/...

99

Capacitor Switching Contactors

K3-18K..
K3-24K..
K3-32K..
K3-50K..
K3-62K..
K3-74K..
K3-90K..
K3-115K..
K3-07..
KG3-07A..
K3-10A..
K3-14A..
K3-18A..
K3-22A..
K3-24A..
K3-32A..
K3-40A..
K3-50A..
K3-62A..
K3-74A..
K3-90A..
K3-115A..
K3-151A..
K3-176A..
K3-210A..
K3-260A..
K3-316A..
K3-450A..
K3-550A..
K3-700A..
K3-860A..
K3-1000A..
K3-1200A..
KG3-10A..
KG3-14A..
KG3-18A..
KG3-22A..
KG3-24A00
KG3-32A00
KG3-40A00
K3-10A00-40
K3-14A00-40
K3-18A00-40
K3-22A00-40
K2-23A00-40
K2-30A00-40
K2-37A00-40
K2-45A00-40
K2-60A00-40
K3-116A00-40
K3-151A00-40
K3-176A00-40
K3-210A00-40
K3-260A00-40
K3-316A00-40

33
33
33
33
33
33
33
33
12
39
20, 21
21
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
30, 31
31
31
31
31
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32

P1T, K2U..PT
P1W, K2U..PW
P1W18P

96
96
96

Coil Voltage Ranges for Contactors K1


for Contactors K3
Contactor Relays, AC Operated
Contactor Relays, DC Operated
Contactors, AC and DC Operated

Contactors, DC Solenoid Operated

Contactors 4-pole

D .O.L. Starters with Start-Stop Push Buttons


D.O.L. Starters with Selector Switch
D.O.L. Starters with Selector and Pneumatic Switch

Description

Type

Electronic Timer Off-delay


Electronic Timer On-delay
Electronic Timer for Star-Delta Starters
Enclosures for Contactors
Enclosures for D.O.L. Starters

K2-TA..
K2-TE..
Y9..
P1
P1R

35
35
77
97
97

Feeder Groups for Contactors K3


Fourth Pole for Contactors K3
Fuse Holders

K3-../FG...
NP..
K2-F

40
37
36

H eating Element for D.O.L. Starters

K2-HR

97

Indicator Units, Coil Current Indicator


Indicator Units, Lens Caps for Indicator Units
Indicator Units, Voltage Indicator
Interface

K2-IN.
LG9743..
K2-UN.
K2-IM

Latch

K2-L..

Marking Systems for Contactors


Mechanical Interlock
Mini Contactor Relays
Mini Contactors

Momentary Contacts for Contactors K2


Mounting Bar for Electronic Timer Y9..
Mounting Parts for Contactors

LG.., P...
LG..
K1-07D..
K1-09..
K1-12D..
K1-09F..
K1-09L..
K1W09D..
K1W12D..
K1W09L..
R20..
R25..
R40..
R63..
HTN..
LG7735
K2-..SM, P...

Parallel Connectors
Pneumatic Timer
Pole Changing Starters Open Type
Pole Changing Starters Steel Sheet Enclosed

LG..
K2-TP..
K3PU..
K3PU..B

38
35
80
80

Rectifier with Fuse Holder


Reversing Starters Connector

K2-RF.
K1W-VB
K3W-VB..
K3WU..
KW3-..
K2WU..B

36
14
78
78
80
78

U12SM
U3/32SM
U3/42G
EK../..
K../4..
K3Y-VB..
K3Y..
K3Y..P
K3Y..B
RC-K1
RC..
RC-R..
K2-E...
VG-K2/..

105
105
105
42
40, 41
77
74
76
76
10
38
117
38
38

Mini Reversing Starters


Modular Contactors

Reversing Starters Open Type


Reversing Starters Steel Sheet Enclosed
Sets for Single Mounting Thermal Overload Relays
Spare Contacts for Contactors
Spare Coils for Contactors
Star-Delta Starter Connector
Star-Delta Starters Open Type
Star-Delta Starters Plastic Enclosed Type
Star-Delta Starters Steel Sheet Enclosed Type
Suppressor Units, RC-units
RC-units
RC-units
Varistor
Varistor
T erminal Block (2 term. insulated) f. Contactors K2
Terminal Block (2 term. interconn.) f. Contactors K2
Terminal Covers for Contactors
Thermal Overload Relays

with Slow Tripping Characteristic

D677E

K2-SK
K2-DK
LG..
U12/16A .. K1
U12/16E .. K1
U12/16EQ .. K1
U12/16E .. K3
U12/16EQ .. K3
U3/32 ..
U3/42 ..
U3/74 ..
U85 ..
U180 ..
U320 ..
U800 ..
UAT..

Page

36, 97
97
36, 97
36
36
38
37
8
10
10
12
12
14
14
14
116
116
116
116
34
77
36, 38

34
34
37
102
102
102
103
103
74,103
74,103
75,104
75,104
75,104
104
104
104

125

You might also like