500kV Single-phase Oil-immersed Convert Transformer

http://www.china-power-transformer.com/500kV-Single-phase-Oil-im...

CTSS always commits itself to be the No. 1 among all top Ultra-voltage oil-immersed power transformer, HV power transformer and Special power & distribution power transformer suppliers in China.

Home

About CTSS

CTSS Products

Certificates & Reference

Download & Knowledge

Sevices & Solutions

News Center

Contact us

Home >> CTSS Products >> Power Transmission >> Oil-immersed transformer(OIT)
Product Search

500kV Single-phase Oil-immersed Convert Transformer

Product Category Power Generation


Hydro Turbine Generator Units Diesel Generator Set Gas Generator Set Special Application

Power Transmission
Oil-immersed transformer(OIT) Dry-type transformer(DTT) Special utility transformer(SUT) Gas insulation switchgear(GIS) Reactor Auxiliary electrical equipments

500kV Single-phase Oil-immersed Convert Transformer Product Details

Power Distribution
Switchgear Mini-substation Energy meter

General: Converter transformers are one of the major components in a converter station to connect the convert bridge with AC system and providing one ungrounding natural point three phase convert voltage. Converter transformers are the next significant component parts in a converter station. The key elements to consider are weights, electrical losses, availability and costs.Converter transformer's main task is to link the AC grid with the converter valves.
CTSS digests and absorbs the advanced manufacture technology of the world, accordingly develops on its own hands 500kV transformers on the basis of CTSS` own experiences and advantages.

News Letter
Get updates, discounts and special offers to win cash prizes! Your Email Address Subscribe

Standards: IEC-76 .1-1993 Power Transformers: general IEC-61378: convertor transformer IEC-60076-3: 2000 Power Transformers Insulation levels, dielectric tests and external clearances in air IEC60076-4-2002 Power Transformers part4 guide to the lighting impulse and switching impulse testing-power transformers and reactors IEC-60076-5:2000 Power Transformers ability to withstand short circuit JB/T3837-1996 Approaches for Editing Type of Transformer GB1094.1.2-1996 Manufacturing Standard of Power Transformer GB1094.3.5-2003 Manufacturing Standard of Power Transformer GB/T 6451-2008 Technical Parameters and Requirements of the Three-phase Oil-immersed Power Transformer Techniques Design: Electromagnetic calculations: Adopt most advanced design software, SolidWorks three-dimensional software and to guarantees all performance indexes Strength analysis: COMOS software Leakage magnetic distribution and its electro-dynamic force: leakage magnetic field analyzing software Electrical insulation: Power frequency electrical field calculating software and lightning over-voltage winding potential distribution calculating software for calculating of gradient distribution of main insulation, longitudinal insulation and impulse voltage in the windings as well as that of winding terminals. Manufacture: Core: effectively upgrade transformers no-load performance by below methods: Adopt high-quality imported silicon steels

Three phase five limb drawing plate structure Five-step of laminated, fully mitered, with the technique of none-pile on upper yoke Meanwhile, appropriate magnetic flux density and the auto-oscillation frequency of cores are selected for lowering transformers sound
level. Winding: Optimize winding transposing to effectively reduce load losses and eddy current losses as well.

Zigzag oil conduit structure to lower average temperature rise and the hot-spot temperature rise and thereby extend transformers service
life. Core structural parts: decrease the stray losses by lowering eddy current losses, drawing plates of core or minimizing slots on the basis of the location of core structural parts. Transformer tank: combining magnetic blocking and copper blocking methods to reduce the stray losses. Features of products: Low loss Low noise No hauling With innovation in safety Reliability assured Low maintenance Fully tested and certified Suits local conditions Cost effective Easy operation Brief specification: Voltage class: 500kV or 550kV

1 de 2

05/05/2013 12:53

500kV Single-phase Oil-immersed Convert Transformer

http://www.china-power-transformer.com/500kV-Single-phase-Oil-im...

Capacity: 100000334000kVA Short circuit impedance: 14% No load current: 0.15~0.25% Losses: no-load losses is strictly comply with IEC standard requirements

Typical specification: Model: 730000-500kV Rated voltage:500kV Rated Capacity:730000kVA Type: Three Phases, OLTC, Power Transformer Application: 500kV power system of power plant, substation, mining enterprise and etc.

500kV Single-phase Oil-immersed Convert Transformer Related Products

11kV Single-phase Pole-mounted Distribution Transformers

90kV Three-phase On-loadtap-changer Power Transformer

Oil-immersed Amorphous Alloy Core transformer

400kV Step-down Oil-immersed Power Transformer

500kV Three-phase Oil-immersed Power Transformer

35kV Three-phase Oil-immersed Transformer

11kV Low Voltage Oil-immersed Distribution Transformer

33kV Step-down Three-Phase 110kV Step-down Electrical Distribution-transformer Power Transformer

500kV Single-phase Oil-immersed Convert Transformer

10kV Hermetically/fully-Sealed Distribution Transformer

230kV Three Phase Oil-immersed Auto Power Transformer

90kV Step-down Three-phase Power Transformer