Eea-Pam 561 A 12
Eea-Pam 561 A 12
Eea-Pam 561 A 12
Accessories
Front Panel
LEDs [1] 24V power supply input, green [2] 15V control supply output, green [3] Drive (solenoid) enabled, yellow [4] Overload, red [5] LVDT failure, red [6] Drive level to solenoid, yellow Potentiometers [7] Deadband compensation, flow P to B [8] Deadband compensation, flow P to A LED [9] Ramps enabled, yellow Potentiometers [10] Acceleration ramp [11] Deceleration ramp Monitor points J [12] MP1: Conditioned input signal [13] Common ground (0V) [14] MP2: LVDT (spool) position Y
2 4 6 1 3 5 +/ P B A AUTO 24/15 TEST VALVE AUTO TEST LOOP
[15] Mode switch TEST VALVE setting AUTO function setting TEST LOOP setting [16] Test potentiometer LEDs
0 +
[17] Controller active, yellow [18] Sensor out of range, red Potentiometers [19] Maximum closed-loop velocity + [20] Maximum closed-loop velocity LEDs [21] Open-loop command (+) active [22] Open-loop command () active Potentiometers [23] Open-loop command + [24] Open-loop command Monitor points J [25] MP3: Output signal of sensor with current output, non-inverting [26] MP5: Conditioned sensor signal, "10V full scale [27] MP6: Controller output [28] MP4: Output signal of sensor with current output, inverting
t t
V+ V
This product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Wiring practices relevant to this Directive are indicated by Electromagnetic Compatibility (EMC) .
GB-2475
C.2
Operation Non-contact optical sensors measure the position of the strip edge. The output from a sensor is an electrical signal, which is fed to the strip guidance controller (signal ranges 0 to 20 mA, 4 to 20 mA, 0 to +10V, or 0 to +24V). When activated, the strip guidance controller maintains the strip edge exactly in the center of the measuring range. If the position of the strip edge deviates from the center of the measuring range, the controller causes the actuator to move the strip edge back into position. When closed-loop control is activated by the digital input signal Automatic, the strip edge is moved from its current position into the measuring range of the
sensor. The maximum actuator velocity (forwards and reverse) can be set on the front panel. Whenever the strip edge leaves the measuring range of the sensor, the controller generates a digital output signal which can be processed by the machine controller. If closed-loop control is not activated, the controller can be operated open-loop. In this case the actuator travels at the velocity set by potentiometer V+ when digital input set + is activated. V and digital input set are used for movements in the reverse direction. A built-in test function together with front panel monitor points, considerably simplify start-up and fault diagnosis.
Model Codes
Amplifier model EEA-PAM-523-E-32 EEA-PAM-525-E-32 EEA-PAM-533-E-32 EEA-PAM-535-E-32 EEA-PAM-541-E-32 EEA-PAM-553-E-32 EEA-PAM-561-E-32 EEA-PAM-568-E-32 EEA-PAM-581-E-32 For valves KDG4V-3 With type H KDG4V-5 coils only KFDG4V-3 KFDG4V-5 KHDG5V-5/7/8 zero-lap KSDG4V-3 KFDG5V-5/7 KFDG5V-8 KHDG5V-5/7/8
Operating Data
Power supply Control (output) supplies Differential inputs for sensor: Voltage input, non-inverting Voltage input, inverting Current input, non-inverting Current input, inverting Digital inputs (opto-isolated): Set + Set Automatic Drive enable Ramp enable zbd32 See appropriate base amplifier, e.g. for EEA-PAM-535-E-32 see EEA-PAM-535-A-32 z22 +15V for LVDTs only d2 d6 d8 d12 d22 d20 d18 z24 +24V max., Ri = 100 k 24V max., Ri = 100 k 20 mA max., Ri = 100 20 mA max., Ri = 100
24V DC nom., 20 to 40V DC max., Ri = 2,7 k 24V DC nom., 20 to 40V DC max., Ri = 2,7 k 24V DC nom., 20 to 40V DC max., Ri = 2,7 k Enable = 9,8 to 40V Disable = 0 to 4,8V or open, Ri = 47 k b24 Enable = 9,8 to 40V Disable = 0 to 4,8V or open, Ri = 47 k
Continued on next page
C.3
Digital output (opto-isolated): Out of range Potentiometers: Deadband compensation Ramp time adjustment Closed-loop velocities Open-loop command
d24 24V DC nom. Short-circuit proof. Imax. = 100 mA Separate controls for each direction from spool-centered position 0 to 50% of max. current Separate controls for acceleration and deceleration 50 ms to 5 sec Separate controls for forward and reverse 5 to 100% Separate controls for forward and reverse 0 to 100% MP1: Conditioned input signal, "10V MP2 LVDT (spool) position, "10VY MP3: Output signal of sensor with current output, non-inverting 0 to 2V = 0 to 20 mA MP4: Output signal of sensor with current output, inverting 0 to 2V = 0 to 20 mA MP5: Conditioned sensor signal, "10V MP6: Controller output, "10V All monitor points are short-circuit proof. In all cases: R(out) = 10 k Enable amplifier (on pin z24) when switching power on HIGH when alarm is activated Output = Supply volts minus 2 volts I = 50 mA max. LOW when solenoid overload has occurred. (Maintained until reset) Output = 0 to +/2 volts Output resistance = 50 ohms Disable and re-enable on pin z24 3-position switch for: Valve test mode Controller test mode Automatic operation mode Caution: Before setting the mode switch to either Test valve or Test loop ensure that the test potentiometer is set to 0, otherwise sudden movements of the actuator may occur. 0 to 50_C (32 to 122_F) 25 to +85_C (13 to +185_F) 0,4 kg (0.88 lb) approx. 9170 2468 9062 See catalogs: 2419 2460 2462 and 2315
Monitor points (Numbers corresponding to the numbering on the front panel and in the circuit diagram)
z12
Operating temperature Storage temperature Mass Installation and start-up guidelines (supplied with product) Installation wiring requirements for Vickers electronic products Application notes (available on request) Supporting products: Power unit options Electronic accessories Portable test equipment
Y Solenoid current for EEA-PAM-523/525-E models.
C.4
EEA-PAM-533/535-E example Y
Read circuit in conjunction with that for relevant base amplifier EEA-PAM-5**-A
+15V +10V 10V 15V "15V Set + Set Automatic Logic Gnd Voltage inputs Noninverting d22 d20 d18 d28 d2 d4 Inverting d6 MP4 Current inputs Gain 70% Gain Offset A S A + Test Open loop command + V+
bdz32 24V Power zero bdz30 b24 Ramp enabled MP1 Conditioned input signal Deadband compensation B
z24
Enabled
Drive enable
Deadband compensation A
Noninverting
z26 z28 Solenoid current z22 b16 b14 MP2 LVDT (spool) position J LVDT failure LVDT Sol. B Acc. Dec. Ramp
Inverting
d12 MP3
3-position switch
d26 d24
+24V Out of range Gnd Valve. Actual connections see table on next page.
MPx designates the serial number x of the monitor point on the front panel.
Out of range
d28
Customers protective ground connection. Y See footnote at bottom of Application Examples. J Solenoid current for EEA-PAM-523/525-E models. Warning: Electromagnetic Compatibility (EMC) It is necessary to ensure that the valve is wired up in accordance with the connection arrangements shown in this leaflet. For effective protection, the users electrical cabinet, the valve subplate or manifold and the cable screens should be connected to efficient earth (ground) points. The metal 7-pin connector part no. 934939 should be used for the integral amplifier. In all cases, both valve and cable should be kept as far away as possible from any source of electromagnetic radiation such as cables carrying heavy current, relays and certain kinds of portable radio transmitters, etc. Difficult environments could mean that extra screening may be necessary to avoid the interference.
C.5
Amplifier type
Solenoid with LVDT and/or for flow P to B b26/b28 b26/b28 b26/b28 b26/b28
Solenoid without LVDT, or on pilot valve z26/z28 z26/z28 z26/z28 z26/z28 z26/z28 z26/z28 z26/z28 z26/z28 z26/z28
Pilot-stage LVDT, (black plug): Pin 1 Pin 2 Pin 3 Pin 4 z14 z14 z22 z22 z16 z16 Not connected Not connected Not connected Not connected Not connected Not connected Not connected Not connected Not connected
Main-stage LVDT, (gray plug): Pin 1 Pin 2 Pin 3 Pin 4 b14 b14 b14 b14 b14 b14 b14 z22 z22 z22 z22 z22 z22 z22 b16 b16 b16 b16 b16 b16 b16 3rd angle projection Not connected Not connected Not connected Not connected Not connected Not connected Not connected Not connected Not connected
DIN 41612 F48 male connector. Mating connector must be an F48 female type.
7,92 (0.31)
z - pin row b - pin row d - pin row Components envelope M2,5 x 11 (0.43) long collar screws supplied with panel for fixing 2,5 (0.1)
128.4 (5.06)
100 (3.94)
3 (0.12)
7,2 (0.28)
C.6
Application Examples
EEA-PAM-533/535-E amplifiers with KFDG4V-3/5 valves Y Strip guidance control, stack height control Position sensor with current output
Power supply 24V
+24V
d26
bdz32
+24V
+24V
d26
bdz32
+24V
Set + d22 Set d20 Automatic d18 24V Out of range Logic Gnd d24 d28
bdz30 Power Gnd Drive z24 enable Ramp b24 enable z26 z28 1 2
Set + d22 Set d20 Automatic d18 24V Out of range Logic Gnd d24 d28
bdz30 Power Gnd Drive z24 enable Ramp b24 enable z26 z28 1 2
Solenoid
Solenoid
KFDG4V-3/5 UB 0...20 mA S I Position sensor Sensor Gnd d12 d10 b26 b28 b16 z22 b14 1 2 3 2 1 UB 0...10V LVDT S U Position sensor Sensor Gnd d2 d4 b26 b28 b16 z22 b14
KFDG4V-3/5 1 2 3 2 1
Solenoid
Solenoid LVDT
+24V
d26
bdz32
+24V
+24V
d26
bdz32 bdz30
+24V
Set + d22 Set d20 Automatic d18 24V Out of range Logic Gnd UB 0...20 mA S I UB 0...20 mA S I Position sensor Sensor Gnd d8 d4 Sensor Gnd d12 d10 d24 d28
bdz30 Power Gnd Drive z24 enable Ramp b24 enable z26 z28 1 2
Set + d22 Set d20 Automatic d18 24V Out of range Logic Gnd d24 d28
Power Gnd Drive z24 enable Ramp b24 enable z26 z28 1 2
Solenoid UB 0...10V S U Solenoid LVDT S U Position sensor Sensor Gnd UB 0...10V Sensor Gnd
Solenoid
KFDG4V-3/5 1 2 3 2 1
Solenoid LVDT
d6 d10
Y Other amplifier/valve combinations differ in respect to the LVDT and solenoid connections; see catalog 2464 for the relevant base amplifier EEA-PAM-5**-A-32.
C.7