ST5484ESeismicVelocity420mATransmitter

2PinMILConnector (OptionD=4) 4PinTerminalBlock (OptionD=3) 2PinTerminalBlock (OptionD=2) FlyingLeads (OptionD=0or1) (2wireshown;4wire alsoavailable)

Overview
TheST5484Eisaselfcontainedseismicvelocity transmitterthatincorporatesapiezoelectric accelerometer,signalintegrator,RMSpeak detector,and420mAsignalconditionerintoa singlepackagethatcanbemounteddirectlyon themachinecaseorbearinghousingwithout needofanyinterveningsignalconditioning equipment.Theamplitudeoftheintegrated acceleration(velocity)signalisconvertedtoa proportional420mAsignalthatiscompatible withmostindustrialprocesscontrol instrumentationsuchasPLCs,DCSs,andSCADA systemsthatcanprovidetrendingand/or alarmingcapabilitiesforasimplifiedvibration monitoringstrategy. Whentheflyingleadorterminalblock connectoroptionsarechosen,thetransmitteris designedforusewithoutneedofaseparate environmentalhousingandcandirectlyaccept conduit.Itcanbeusedwithbarriersfor intrinsicallysafeinstallations,orwireddirectly toexplosionproofconduitfittingsforexplosion proofinstallations,reducingtotalinstalledcosts.
NeedALocalDisplay? Whencontinuous,localindicationof vibrationlevelsisrequiredatthe transmitter,theMetrixST5491Eprovides thesecapabilities.Itssensingand transmitterelementsaresimilartothe5484E,butit includesaconvenient2digitLCDdisplayinanintegral conduitelbowandisratedforuseintemperaturesfrom 10Cto+70C.Refertodatasheet1004598forordering informationanddetailedspecifications.

Document1004457 Rev.K(Nov2011)

Datasheet
ST5484ESeismicVelocity420mATransmitter

Applications

monitoringmanymachinesasareliable indicatorofdamagingvibratoryenergy,withthe notableexceptionofmachineswithfluidfilm bearings,whichareusuallybetteraddressedby shaftobservingproximityprobes. Casingdisplacementisnotapractical measurementtomakedirectly,andistypically justanintegratedseismicvelocity measurement.Assuch,theprimarydecision whenselectingaseismicsensorwillusuallybe whethertomeasurecasingvelocityorcasing acceleration.Asnotedabove,casingvelocity willoftenbemoreappropriatebecauseittends tobeamorereliableindicatorofdamaging vibratoryenergyoverabroadfrequency spectrumforlowtomediumspeedmachinery.
NOTE: Formachineswithfluidfilmbearings,shaft observingproximityprobeswillprovidemore effectivevibrationmeasurementsthanseismic transducersduetotherotordynamicsofthemachineand theattenuationofvibratoryenergythroughafluidfilm boundary.Accordingly,Metrixrecommendsandprovides proximityprobesandassociated420mAtransmittersor monitoringsystemsforsuchapplications. Formachineswithrollingelementbearingsandrunning above6,000rpm,and/orwhereimpulsivecasingvibration occurs,accelerationmaybeabettermeasurement.In suchsituations,itisrecommendedthatyouconsultwith yournearestMetrixsalesprofessionalwhocanreviewyour applicationandassistwithselectionoftheproper transducertypeandassociatedtransmitterormonitoring system.

Inapplicationswherethefeaturesandfunctions ofastandalonemonitoringsystemmaynotbe warranted,theuseofavibrationtransmitter maybeanappropriateapproach. TheST5484Eisintendedforgeneralpurpose vibrationmeasurementsonawiderangeof rotatingandreciprocatingmachinerywith rotativespeedsbetween120rpmand6,000 rpm.Seismicmeasurementsareparticularly wellsuitedformachinesthatincorporate rollingelementbearingsbecauseshaftvibration insuchmachinesisusuallytransmitteddirectly throughthebearingtothebearinghousing, withoutsubstantialdampingorattenuation. Seismictransducersarealsoabletomeasure vibrationthatdoesnotoriginateattheshaft, suchasbearingrelatedwearanddefects, footing/foundationproblems,pipingresonances thatarecoupledtothemachine,etc. WhyMeasureVelocity? Accelerationanddisplacementlevelsareheavily influencedbythefrequency(ies)atwhichthe vibrationisoccurring,whilevelocitylevelsare muchlessinfluenced.Thus,although acceleration,velocity,anddisplacement measurementsareallinterrelated mathematically,seismicvelocitymeasurements tendtobemoreconsistentoverawiderangeof frequenciesthaneitherdisplacementor acceleration.Consequently,broadband (sometimescalledoverallorunfiltered) velocitymeasurementsareappropriatefor

Document1004457 Rev.K(Nov2011)

Page2of12

Datasheet
ST5484ESeismicVelocity420mATransmitter

Features
HazardousAreaApprovalsNorth American(CSA),Brazilian(INMETRO),and European(ATEX&IEC)approvalsavailable. DynamicSignalAvailability2wire versionsprovidea420mAvelocity proportionalsignalforeasyconnectionto PLCs,DCSs,andotherplantcontrolsystems. Optional4wireversions*alsoprovidethe rawaccelerationsignal(100mV/g)foruse withvibrationdatacollectorsandanalyzers. VarietyofConnectionOptionsFlying leads,terminalblock,andMILtype connectorsavailable. ConduitReady**Terminalblockand flyingleadoptionshaveconduitthreadson topofsensor.Nospecialhousingsare requiredforconnectionofconduit. Rugged,IndustrialDesignRobust constructionoffersoutstandingdurability; builtinbaseandhousingstrainprotection helpsensurethatovertorqueingsensorto machineandsensortoconduitconnections wontdamageinternalsorbody. HighandLowPassFilterOptionsThe ST5484Ecanbeorderedfromthefactory withawidevarietyoflowpassand/orhigh passfilteroptionstopreciselytailorthe bandoverwhichvibrationismeasured. PolarityIndependentWiringOur patentedIPTtechnologyallowslooppower tobeconnectedwithoutregardtovoltage polarity,reducingfieldwiringerrorsand ensuringthattherawaccelerationoutput* isnotphaseinverted.

MultipleMountingOptionsIntegraland removablemountingstudoptionsavailable inbothmetricandEnglishthreadsizes;flat basemountingadaptersalsoavailable. LoopPoweredRunsonnominal24Vdc powersuppliedbythe420mAcurrentloop WideSupplyVoltageRangeAcceptsloop powervoltagesfrom11to30Vdc. RMSAmplitudeDetectionMeasuresRoot MeanSquare(RMS)vibrationamplitude. OptionsavailableforTrueRMSorscaled RMS(RMSx2)forderivedpeak. NumerousFullScaleRangesThefullscale rangesprovidedinoptionAAAreflect frequentlyorderedranges;however,many others(toonumeroustolist)arealso available.Consultfactoryforapplications requiringotherfullscaleranges.
*Dynamicrawaccelerationsignalavailablewith4 wireversionsonly(orderingoptionsC=1andC=3). **Metrixrecommendstheuseofflexible(ratherthan solid)conduitwhenpossible.Solidconduitmaybe morepronetotheintroductionofpreloadforceson thesensorandcorrespondingalterationofthe sensorsvibrationresponse.

Document1004457 Rev.K(Nov2011)

Page3of12

Allspecificationsareat+25C(+77F)and +24Vdcsupplyvoltageunlessotherwisenoted.
Supply Voltage (seealsonote undermax loop resistance) CircuittoCase 500Vrms Isolation Outputs 420mA Proportionaltovelocityfullscale range(4mA=0vibration,20mA= fullscalevibration) Maximum4 RL=50x(Vs11)whereVs = 20mAloop SupplyVoltageattransmitter resistance terminals. Inputs 1130Vdc(24Vdcnominal); MetrixpatentedIPTindependent polaritydiodebridgecircuitallows voltagetobeconnectedwithout regardtopolarity. Dynamic SignalOutput Impedance 10k

Datasheet
ST5484ESeismicVelocity420mATransmitter

Specifications

NOTES: 1.Thedynamicsignaloutputisshortcircuit protectedbymeansofa10kresistor, resultinginarelativelylargeoutput impedance.Manydatacollectorsand analyzershaverelativelylowinput impedances(100korless)whichwillload thisdynamicoutputandattenuatethe signalby10%ormore.RefertoTable1for thedBandpercentageattenuationfor variousloadimpedances.

2.Becausethe5484isalooppowered devicewithlowoperatingpower,the dynamicsignaloutputrequiresabuffer amplifierforcablerunsinexcessof16feet (5meters).Longercablerunswillalso introducedistributedcablecapacitancethat actsasalowpassfilter,attenuatinghigh frequencysignalcontent.Insuch situations,consultthefactoryforassistance selectinganappropriatelowcapacitance cable.

NOTE:Forevery50ohmsofresistancein the420mAloop,1Vdcabovethe minimumsupplyvoltage(11Vdc)mustbe availableatthetransmitterterminals.For example,12Vdcatthetransmitter terminalswillallowa50loopresistance; 30Vdcatthetransmitterterminalswill allowa950loopresistance.For intrinsicallysafeapplications,theuseofa passivezenerbarrierwillincuravoltage dropofapproximately8.1voltsatthe barrier,andtheloopsupplyvoltageis limitedto26Vdc.Thus,withpassive barriersanda26Vdcsupply,themaximum availablevoltageatthetransmitterwillbe 17.9Vdcandthecorrespondingmaximum loopresistancewillbe345.

Recommended

Minimum Load Impedance (Zload)for Dynamic Signal Connection

500k (seealsonote1above)

Dynamic Signal

100mv/gacceleration,filteredto samefrequencybandas proportionalvelocity(seeordering optionsEandF)

Frequency Response(+/ 3dBpassband) OptionalHigh 5,10,20,50,100,or200Hz(must PassFilter bespecifiedattimeofordering) Corner

SignalProcessing 2Hz 1500Hz(standard) 2Hz2000Hz(optional)

Document1004457 Rev.K(Nov2011)

Page4of12


HighPass RollOff OptionalLow PassFilter Corner LowpassRoll Off Accuracy 12dB/octave 230,250,500,or1000Hz (mustbespecifiedattimeof ordering) 12dB/octave 2.5%(withinpassband) 4%(atcornerfrequencies) 5.0in/sec(othersbyrequest) 0.5in/sec(othersbyrequest) in/sec(standard) mm/sec(availablebyrequest) TrueRMSdetector;fullscalemay beorderedwithTrueRMSunitsor scaledRMS(RMSx2)forderived peakmeasurements. SeeorderingoptionAAA. Physical 40Cto+100C(40Fto+212F) 0.9lbs(0.36kg) RefertoFigures1and2 Sameasmountingstudaxis Any 303stainlesssteel(standard) 316stainlesssteel(optional) Enclosure Rating Connector Types NEMA4X IP66 FlyingLeads(2and4wire) MILC5015(2wireonly) TerminalBlock(2and4wire) (refertoorderingoptionD) 95%,noncondensing (flyingleadandterminalblock versions) 100%condensing (MILstyleconnector) Approvals Yes CSA ATEX IECEx INMETRO GOST(consultfactory) (refertoorderingoptionC)

Datasheet
ST5484ESeismicVelocity420mATransmitter

Humidity

MaximumFull Scale MinimumFull Scale FullScale RangeUnits Amplitude Detection

CEMark Hazardous Areas

Operating Temperature Weight Dimensions SensitiveAxis Axis Orientation Enclosure Material

RecommendedISBarriers Passive(Zener MTL 7787+orequal Type) Active(Zener MTL7706orequal Type) Active MTL5541orequal (Galvanic Type) ST5484E Vmax:30V Entity Imax:100mA Parameters

Document1004457 Rev.K(Nov2011)

Page5of12

Datasheet
ST5484ESeismicVelocity420mATransmitter
C D 1 3 6 E F

OrderingInformation

1 2 3 4 5 6 7 8 0

HazardousAreaCertification3,4 CSA/NRTL/C,ClassI,Div2,GrpsAD (XP)CSA/NRTL/C,ClassI,Div1,GrpsBD andClassII,Div1,GrpsEG (I.S.)ATEX,EExiaIICT4 (I.S.)CSA,ClassI,Div1,GrpsAD (I.S.)INMETRO,BRExiaIICT4 (XP)INMETRO,BRExdIICT4 (I.S.)IECEx,ExiaIICT4 (XP)ATEX/IECEx,ExdIICT4 ConnectionType3 24FlyingLeads,2wire; (420mAoutputonly) 24FlyingLeads,4wire; (420mAoutputanddynamicraw accelerationsignal) TerminalBlock,2wire;5 (420mAoutputonly) TerminalBlock,4wire;5 (420mAoutputanddynamicraw accelerationsignal) 2PinMILStyle(MILC5015), (420mAoutputonly) 72FlyingLeads,2wire; (420mAoutputonly) 72FlyingLeads,4wire; (420mAoutputanddynamicraw accelerationsignal) HighPassFilter

ST5484AAABCDEF SeismicVelocityTransmitter

AAA FullScaleRange1

1 2 11.0in/sec(25.4mm/s)peak2 1 2 20.5in/sec(12.7mm/s)peak2 1 2 32.0in/sec(50.8mm/s)peak2 1 2 45.0in/sec(254mm/s)peak2 1 2 60.8in/sec(20.3mm/s)peak2 1 3 23.0in/sec(76.2mm/s)peak2 1 5 11.0in/sec(25.4mm/s)trueRMS 1 5 20.5in/sec(12.7mm/s)trueRMS 1 5 32.0in/sec(50.8mm/s)trueRMS 1 5 45.0in/sec(254mm/s)trueRMS 1 5 60.8in/sec(20.3mm/s)trueRMS 1 6 23.0in/sec(76.2mm/s)trueRMS

HousingMaterial&StudSize

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 30

303SShousing,NPTstud 303SShousing,NPTstud 303SShousing,x24UNFstud 303SShousing,x20UNFstud 303SShousing,M8x1.012stud 303SShousing,M10x1.2512stud 303SShousing,x20UNCstud 303SShousing,x28UNFstud 303SShousing,M8x1.2512stud 303SShousing,x16UNCstud 316SShousing,NPTstud 316SShousing,NPTstud 316SShousing,x24UNFstud 316SShousing,x20UNFstud 316SShousing,M8x1.012stud 316SShousing,M10x1.2512stud 316SShousing,x20UNCstud 316SShousing,x28UNFstud 316SShousing,M8x1.2512stud 316SShousing,x16UNCstud 303SShousing,x13UNCstud 316SShousing,x13UNCstud

4 5

0 1 2 3 4 5 6 X 0 1 2 3 4 5 X

2Hz(standard) 5Hz 10Hz 20Hz 50Hz 100Hz 200Hz6 Custom(consultfactory)6 LowPassFilter 1500Hz(standard) 500Hz 1000Hz 2000Hz 250Hz6 230Hz6 Custom(consultfactory)6

Document1004457 Rev.K(Nov2011)

Page6of12


NOTES: 1. Smallerdiametermountingstudsarenotableto withstandenvironmentswithsustainedambient vibrationlevelsabove2.0in/sec.ConsultTable2for allowablecombinationsofA&Boptions. TheST5484EusesanRMSamplitudedetectioncircuit. FullscalerangesinpeakunitsusedscaledRMS(i.e., RMSx2).Thederivedpeakmeasurementswill equaltruepeakonlyunderthespecialcaseofapure sinusoid,notcomplexvibrationsignals. HazardousAreaCertificationsarenotcompatiblewith allconnectiontypes.ConsultTable3forallowable combinationsofC&Doptions. Someapprovalsrequiretheuseofintrinsicsafety barriers,othersrequireExplosionProofwiring practices.RefertoTable4. Itmaybedifficulttoconnectwirestoterminalblocks withoptional8200conduitelbowattached.Itis suggestedthatwiresberoutedthroughconduitelbow, thenlandedonterminals,andthenconduitelbow secured.Useofunionadapter8201mayberequired. RefertoAccessoriessectiononfollowingpage. HighandLowPassfiltercornersforstandardfilters mustbeseparatedbyatleastoneoctave(lowpass frequencymustbeatleast2Xhighpassfrequency).All combinationsareallowedexceptE=6andF=4or5. Customfilterswithcloserseparationand/ordifferent rolloffsmaybeavailableinsomeinstances.Consult thefactoryifcustomfiltersarerequired.

Datasheet
ST5484ESeismicVelocity420mATransmitter
Table2 AllowableCombinationsforA&BOptions
FullScaleRange AAA= 121,122,123,126 151,152,153,156 124and154 132and162 AllowableBoptions (MountingStudSizes) All(norestrictions) 0,1,3, 10,11,13 0,1,2,3,5,9 10,11,12,13,15,19

2.

Table3 AllowableCombinationsforC&DOptions
D 0 1 2 3 4 5 6

3.

1 Y Y Y Y Y Y Y

2 Y Y N N N Y Y

3 N N Y Y Y N N

4 N N Y Y Y N N

5 Y Y Y Y Y Y Y

6 Y Y N N N Y Y

7 N N Y Y Y N N

8 Y Y Y Y N Y Y

4.

5.

Table4 Approvalsandcorrespondingwiring requirements


ExplosionProofWiringRequired C= Agency ApprovedAreas I.SBarriersorXPWiringNot Required

6.

Table1AttenuationofDynamicSignalversusLoad Impedance(Zload)
DataCollector/ AnalyzerLoad Impedance(Zload) 10M 5M 2M 1M 500k 200k 100k 50k 20k 10k DynamicSignal Voltage Attenuation(dB) 0.01dB 0.02dB 0.04dB 0.09dB 0.18dB 0.43dB 0.84dB 1.61dB 3.57dB 6.10dB DynamicSignal Voltage Attenuation(%) 0.1% 0.2% 0.5% 1% 2% 5% 9% 17% 33% 50%

1 2 3 4 5 6 7 8

CSANRTL/C CSANRTL/C ATEX CSA INMETRO INMETRO IECEx ATEX/ IECEx

ClassI,Div2,GroupsAD ClassI,Div1,GroupsBD ClassII,Div1,GroupsEG ExiaIICT4 ClassI,Div1,GroupsAD BRExiaIICT4 BRExdIICT4 ExiaIICT4 ExdIICT4


Document1004457 Rev.K(Nov2011)

I.S.BarriersRequired

Page7of12

Datasheet
ST5484ESeismicVelocity420mATransmitter

Accessories
PartNumber 8200001 Description ConduitElbow&Reducer MatestotopofST5484Eandprovidesaccesstoandphysical protectionoffieldwiring.SuitableforClassI,Div.1(GrpsC&D) andClassII,Div.1(GrpsE,F&G)hazardousareas.Conduit entryis1NPT(1NPTto"NPTreducerincluded).NEMA4/ IP65. Material:copperfreealuminum. ConduitElbow&ReducerwithTerminalBlock Sameas8200001butincludesterminalblock;conduitentryis 1NPT(1NPTtoNPTreducersupplied) StainlessSteelConduitElbow&Reducer Similarto8200001butwithouthazardousareaapprovalsor NEMA/IPrating.ConduitfittingisNPT. Material:303stainlesssteel. StainlessSteelConduitElbow&ReducerwithTerminalBlock Sameas8200005butincludesterminalblock.Conduitentryis "NPT. Material:303stainlesssteel. ConduitUnion Fitsbetween5484Eand8200XXXconduitelbowwhenthereis notenoughroomrotatetheelbow. SuitableforClassI,Div1(GrpsA,B,C,D)andClassII,Div1(Grps E,F,G)hazardousareas. Material:zincplatedsteel FlangeMountAdapter AdaptsNPTmountingstudon5484Eto3holeflatbase pattern.Holepatternisthreeequallyspaced0.26diameter holeson1.5diametercircle.Adapteris2diameterx0.75 thick. Material:303stainlesssteel FlangeMountAdapter Sameas7084001exceptcenterholeadaptsNPTstudon 5484E. FlangeMountAdapter Sameas7084001exceptcenterholeadaptsx24UNFstudon 5484E.

8200002

8200005

8200006

8201001

7084001

7084002 7084005

Document1004457 Rev.K(Nov2011)

Page8of12

Datasheet
ST5484ESeismicVelocity420mATransmitter

8253002 NPTtoNPTReducerBushing AdaptsNPTstudon5484E(B=0)toNPTmountinghole. Material:303stainlesssteel 2pinMILSplashProofCableAssembly Usedwith2pinMILstyleconnector.Connectorisprotectedby integral,moldedbootwith6.4mm(0.25)diameter polyurethanejacketedcableencapsulatingasingletwistedpair ofconductorsandshield. XXX.X=cablelengthinmeters(example:0037=3.7m) 2pinMILCableAssembly Similarto8978111butwithoutsplashproofboot.

8978111XXXX

8978211XXXX

89782000000

9334111YYYYXXXX

9334211YYYYXXXX

2pinMILConnectorAssembly Similarto8978211butwithoutcable(connectorcanbe disassembledforfieldinstallationofcable) 2pinMILSplashProofCableAssemblyWithArmor Usedwith2pinMILstyleconnector.Connectorisprotectedby integral,moldedbootwith7.1mm(0.28)diameterstainless steelarmorencapsulatingasingletwistedpairofconductors andshield. XXX.X=cablelengthinmeters(example:0037=3.7m) 2pinMILArmoredCableAssembly Similarto9334111butwithoutsplashproofboot.

816975002XXX

93818004

93818018

2wireCableAssembly Usedwith8200001or8200005elbowwhenconduitwillnot beused.2conductor(20AWG)twisted,shieldedpairinPVC jacketedcable.Gripforcablestrainrelief.Connectorismale NPT. Material:zincplatedsteel XXX=lengthinfeet(example:010=10feet) CableGripStrainReliefFitting Usedprimarilywith8978cableassemblieswherecableenters junctionbox.NPTmalethreadtocablegrip.Fitscable diametersfrom0.156to0.25.Completewithsealingringand locknut.Hotdip/mechanicallygalvanizedfinish.Suitablefor NEMA4junctionboxes. CableGripStrainReliefFitting Similarto93818004,butfitslargercablediametersfrom0.4 to0.5,suchascustomersuppliedcablesusedwithterminal blockversionsof5484E(D=2or3).

Document1004457 Rev.K(Nov2011)

Page9of12

Datasheet
ST5484ESeismicVelocity420mATransmitter

OutlineDiagrams


Figure1:OutlinedimensionsofST5484E(all versionsexceptMILStyleConnector). Dimensionsinmm[inches].Optional8200XXX conduitelbowshowninstalled. Figure2:Outlinedimensionsof ST5484EXXXXX4XX(MILStyleConnector). Dimensionsinmm[inches].

Document1004457 Rev.K(Nov2011)

Page10of12

Datasheet
ST5484ESeismicVelocity420mATransmitter

WiringConnections
ConnectorType MILC5015 2wireflyingleads 2wireterminalblock 4wireflyingleads 4wireterminalblock Table5WiringConnectionLegend DynamicSignalConnections NotAvailable NotAvailable NotAvailable Red:Power+ Blue:Power White:DynamicSignal Black:DynamicSignal+ PowerConnections 24Vdcpowermaybe connectedtoallST5484E modelswithoutregardto polarity.Sensoruses IPTindependent polaritydiodebridge circuitthatwillalways orientvoltagecorrectly insidesensor,regardless ofpolarityexternally.
NOTE:AlthoughtheST5484E allowspolarityineither direction,installationsusing I.S.barrierswillneedto observecorrectpolarityatthe barrierinputside.However, thebarrieroutputside(i.e., sensorconnection)maybe wiredwithoutregardto polarity.

PWR

NOTE:+ANDSYMBOLS ARENOTONLABEL


Figure3:TypicalinstallationforsingleST5484E seismicvibrationtransmitter
Document1004457 Rev.K(Nov2011)

Figure4:Typicalinstallationformultiple ST5484Eseismicvibrationtransmitters
Page11of12

Datasheet
ST5484ESeismicVelocity420mATransmitter


Description Manual Specifications InstallationDrawingHazardousAreawithI.S.Barriers(CSA) InstallationDrawingHazardousAreawithI.S.Barriers(CENELEC) InstallationDrawingDiv2/Zone2 MetrixDocumentNumber M9162 9163 9426 9278 1086105

AdditionalDocumentation

MetrixInstrumentCompany

8824FallbrookDrive Houston,TX77064USA (281)9401802 www.metrixvibration.com [email protected]


Trademarksusedhereinarethepropertyoftheir respectiveowners. Dataandspecificationssubjecttochangewithout notice. 2011MetrixInstrumentCompany,L.P.

Document1004457 Rev.K(Nov2011)

Page12of12

You might also like