Sicar@Tia + Diagaddon

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 33

SICAR@TIA Portal

Unrestricted © Siemens AG 2018 siemens.com/automotive


SICAR@TIA Portal
What is SICAR?

Clear Framework
Defined (What & How)

Basic Set of
“Building Blocks”
for Standard

References e.g.:
Opel KL + ZAZ + Luton
FFT, Gestamp, VinFast
Magna, BAIC, JMC

Unrestricted © Siemens AG 2018


Page 2 03/23/2024 VSS Automotive
SICAR Automotive Platform @ TIA Portal

Ranges of application Automotive industry + OEMs + 1st Tiers Library


Bodyshop Assembly without their own automation standard • PLC templates
 based on TIA Portal V14 • HMI templates

Conveyor

HW/SW platform Integrated system


functions
• System diagnostics
Step 7 / WinCC Adv. IPC / Panels
• Code viewer
(LAD/FBD/GRAPH)
• Integr. message system
SINAMICS S7-151x F
Standardization platform
Basic application Documentation
Executable basic project • Online help
PLC + HMI = Start up • Step7 (Project)
Graph/
LAD/ • WinCC Adv. RT
FBD

Extendable Simple architecture

Product design Production planning Production engineering Production execution Service

Unrestricted © Siemens AG 2018


Page 3 03/23/2024 VSS Automotive
SICAR - Coverage of an Automotive software standard

Customer
Responsibility
Plant Specific PLC Plant Specific screens Plant Specific TEC Units Other Interfaces Plant Specific Alarms Plant Specific
programs Documentation
Plant Application

OEM specific
• Supervising system • Plant overview • Process specific • For non-Siemens • Process specific application
• Type control Tec Units products Alarms • For plant specific PLC + HMI
• Station screens
(e.g. Robots and applications
• … • • Sequence control
… applications)
OEM Standard @SICAR

• Other languages
• …
• Conveyor • …
• Roller shutter
• …

Core PLC Project Core HMI Project Basic TEC Units Interfaces for Siemens Alarm/Diagnostics Documentation
Product • Alarm viewer
• Global functions • Menu guided • Rollerbed • Interfaces incl. Basic application
• * PRODIAG / Viewer • Documentation
* Operation modes
SICAR@TIAP

• Operation mode • Lifter Status-/Diagnosis screen * Tec-Units Executable basic project


* Panels Management * RF 300 Ident • DiagAddOn (ready to use)
• Templates for faceplates • Valves * Online HMI-RT
• HMI - Interface * G120D drive • System diagnosis * Online TIAP Step7 PLC + HMI = Start up
• On/Off device * Bool-Variables
• Sequence Startup • Web Server
* Energymeter
• …
• Safety Startup • PN-Diagnosis •
• Production data German / English
• E Stop / Euchner
• Templates for Tec Unit
Doorsystem

PLC HMI Tec-Units AddOn Alarms/Diag. Documentation Coverage of


SICAR platform

Unrestricted © Siemens AG 2018


Page 4 03/23/2024 VSS Automotive
Sample Network structure conveyor

Plant Network
TPx00

WinCC RT Vx

PN/PN-Coupler
Standard und Safe
Communication
Profinet / ProfiSafe / TCP-IP Communication
ET200SP S7-151xF
Other lines

OM-Area

Scalance ET200SP
RB
Connection box
RB

Scalance

MCP

TT

OM-Area

Scalance ET200SP
EXH
Connection box

RB

EXH

QF

KTP900F
Scalance ET200SP RB

Unrestricted © Siemens AG 2018


Page 5 03/23/2024 VSS Automotive
Sample Network structure Bodyshop

Plant Network
IPC 277x

WinCC RT Vx

PN/PN-Coupler
Standard und Safe
Communication
ET200SP S7-151xF Profinet / ProfiSafe / TCP-IP Communication
Other lines

OM-Area Schutztürschalter Werkzeug mit Ventil IP67 Werkplatz mit Werkertor

Scalance ET200SP Ventile ET200eco Elektrical Robot Fanuc RJ3


Euchner Connection box ET200Pro
ET200SP Drive

Scalance Scanner
ET200SP
MCP Sinamics Schweisskoffer
Robot peripherie
(Welding guns, Handling etc.)

CP1604
Other application
(Glue control, ...)
and stat. Components
OM-Area (stat. Welding guns, cap changer, etc.)

Scalance ET200SP Festo ET200eco


Euchner Connection box ET200Pro
ET200SP

Scanner
ET200SP
Schweisskoffer
Sinamics

CP1604

KTP900F
Scalance ET200SP

Unrestricted © Siemens AG 2018


Page 6 03/23/2024 VSS Automotive
SICAR@TIA Portal
Core PLC Project

• Control ON/OFF
Centralized switch ON / OFF function of the control
• HMI
Management of HMI (IPC / Panels) and Push Button panels
Interface between HMI and PLC (prepared for 8 HMI)
• Operation mode management
Realize the management of operation modes
8 operation mode areas prepared
Each operation mode area can change operation mode (AUTO, Manual) independently
• Safety: Startup blocks
Example template for E-Stop and F_OUT with feedback control
Example template for an Euchner gate entry device

Unrestricted © Siemens AG 2018


Page 7 03/23/2024 VSS Automotive
SICAR@TIA Portal
Core HMI Project

• Menu guidance
Headline and Footer

• Operation modes

• Pop Up technology
Legends
Operation modes
Auto / Manual / Single step
Control ON/OFF
Security dialogs
……..

• Overview screens

Unrestricted © Siemens AG 2018


Page 8 03/23/2024 VSS Automotive
SICAR@TIA Portal
Basic TEC Units

• Device ON / OFF
Tec-Unit to control the ON /OFF function of a device with feedback monitoring

• Lifter function
Tec-Unit to control a lifting device with 2 speeds, 2 directions and 2 positions

• Positioning devices
Tec-Unit to control a positioning device with 1 speed, 2 directions and 2 positions.
Tec-Unit to control a positioning device with 2 speeds, 2 directions and 2 positions.
Tec-Unit to control a positioning device with 2 speeds, 2 directions und 2 positions,
including part detection

• Roller bed block


Tec-Unit to control a roller bed with 2 speeds, 1 direction and 1 position.

• Valve control
Tec-Unit to control a valve with 1 cylinder.
Tec-Unit to control a valve with up to 8 cylinders.

Unrestricted © Siemens AG 2018


Page 9 03/23/2024 VSS Automotive
SICAR@TIA Portal
Basic TEC Units – Overview screen

Unrestricted © Siemens AG 2018


Page 10 03/23/2024 VSS Automotive
SICAR@TIA Portal
Basic TEC Units – PLC

Unrestricted © Siemens AG 2018


Page 11 03/23/2024 VSS Automotive
SICAR@TIA Portal
Basic TEC Units – HMI

Unrestricted © Siemens AG 2018


Page 12 03/23/2024 VSS Automotive
SICAR@TIA Portal
Basic TEC Units – Movements

Unrestricted © Siemens AG 2018


Page 13 03/23/2024 VSS Automotive
SICAR@TIA Portal
Interfaces for Siemens Products

• Drive
Interface to control a SINAMICS G120 drive

• Ident
Interface to control read / write functions of data from / to a RF tag.

• Production data
Support of production data (process counter, shift counter, cycle timers and limit values)

• Energy data
Interface to measure and display energy data via AI-EnergyMeter.

• Display of Boolean signals


Display the status and symbolic names of Boolean signals (16 data sets with up to 32
Boolean signals).

Unrestricted © Siemens AG 2018


Page 16 03/23/2024 VSS Automotive
SICAR@TIA Portal
Alarms & Diagnostics

• PN Diagnostics (customized)
Diagnosis and visualization of PROFINet devices
• PLC Diagnostics (customized)
Read and visualize Identification and Maintenance data (I&M data) of the PLC
• System diagnostics (WinCC Control)
Overview about the available devices of the installation
• WEB-Server (WinCC Control)
HTML-Browser provides information about the status of all Webserver based devices
(Identification, diagnosis buffer, device status, messages, communication data and
topology data)
• Alarming (customized)
Multilingual alarm block package. It is possible to create own alarm texts which can be
activated with a trigger bit and displayed in the WinCC alarm control.
• Alarming (ProDiag)
Integrated Process Diagnostic based on ProDiag functionality
• Code viewer (WinCC Control)
Integrated Codeviewer for Process alarms and Graph

Unrestricted © Siemens AG 2018


Page 17 03/23/2024 VSS Automotive
SICAR@TIA Portal
Documentation

• User defined documentation TIA-Portal ES


Available in the TIA-Portal project

• User defined documentation on HMI RT


User defined documentation as a PDF file
Video’s

• Multilingual
Implemented languages are English and German
Additional languages can activated by user

Unrestricted © Siemens AG 2018


Page 18 03/23/2024 VSS Automotive
05/2018

SICAR@TIA Portal – DiagAddOn

Unrestricted © Siemens AG 2018 siemens.com/answers


Software Installation

PLC 15xx IPC Win7 / Win10

Basic DiagAddOn DiagAddOn (VB-Applikation) TIA WINCC Advanced Runtime

Unrestricted © Siemens AG 2018


Page 20 03/23/2024 RC-DE DF S-VS 9 3
Switch WinCC < > DiagAddOn

DiagAddOn (VB-Applikation) TIA WINCC Advanced Runtime

Unrestricted © Siemens AG 2018


Page 21 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Sequence and message block diagnosis (STL)

Unrestricted © Siemens AG 2018


Page 22 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Sequence and message block diagnosis (LAD)

Unrestricted © Siemens AG 2018


Page 23 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Sequence and message block diagnosis

Unrestricted © Siemens AG 2018


Page 24 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Criteria analysis + Sequence synchronisation

Unrestricted © Siemens AG 2018


Page 25 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Message history, Top Ten und Movement screens

Unrestricted © Siemens AG 2018


Page 26 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Message history

Unrestricted © Siemens AG 2018


Page 27 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – RSS Feeds

RSS-Feed
RSS (Rich Site Summary) is a type of web feed which allows users to access updates to online content in a standardized, computer-readable format.
Websites usually use RSS feeds to publish frequently updated information, such as blog entries, news headlines, audio, video.
An RSS document (called "feed", "web feed" or "channel") includes full or summarized text, and metadata, like publishing date and author's name.

RSS-Feed in DiagAddOn
All entries in the message history are automatically stored in a XML-file and can be subscribed as an RSS-Feed.
• Sequence faults
• User messages (Message blocks)
• System messages DiagAddOn
Additional to each entry in the xml-file the system creates a txt-file.
Here you can find all conditions incl. criteria analysis for sequence fault or user message.

Subscribing RSS-Feed e.g. Mail client

Unrestricted © Siemens AG 2018


Page 28 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Multilingual

Unrestricted © Siemens AG 2018


Page 30 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Preparation Seq and MB diagnosis for HMI

DiagGen
- Export of blocks and symbolic in XML-Format (TIA-Openness)
- Convert XML-> s7l, sdf für DiagAddOn

Unrestricted © Siemens AG 2018


Page 31 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Cross reference

The cross reference leads to a significant simplification of programming

E.g. Evaluation of different Types in a tool


-> x-times programmed in sequences where request is neccessary

Now: only once programmed in message block

Unrestricted © Siemens AG 2018


Page 32 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Crossreference

E.g. Flag M100.0 is used several times in different sequences.

Return
to source

Unrestricted © Siemens AG 2018


Page 33 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Teach mode of watchdog times

Automatic measurement of step times in each sequence

Unrestricted © Siemens AG 2018


Page 34 03/23/2024 RC-DE DF S-VS 9 3
DiagAddOn – Version control

Version control for DiagAddOn system blocks

Unrestricted © Siemens AG 2018


Page 35 03/23/2024 RC-DE DF S-VS 9 3
Thank you for your attention!

VSS Automotive, Siemens AG

siemens.com/automotive

Unrestricted © Siemens AG 2018


Page 39 03/23/2024 VSS Automotive

You might also like