Sicar@Tia + Diagaddon
Sicar@Tia + Diagaddon
Sicar@Tia + Diagaddon
Clear Framework
Defined (What & How)
Basic Set of
“Building Blocks”
for Standard
References e.g.:
Opel KL + ZAZ + Luton
FFT, Gestamp, VinFast
Magna, BAIC, JMC
Conveyor
Customer
Responsibility
Plant Specific PLC Plant Specific screens Plant Specific TEC Units Other Interfaces Plant Specific Alarms Plant Specific
programs Documentation
Plant Application
OEM specific
• Supervising system • Plant overview • Process specific • For non-Siemens • Process specific application
• Type control Tec Units products Alarms • For plant specific PLC + HMI
• Station screens
(e.g. Robots and applications
• … • • Sequence control
… applications)
OEM Standard @SICAR
• Other languages
• …
• Conveyor • …
• Roller shutter
• …
Core PLC Project Core HMI Project Basic TEC Units Interfaces for Siemens Alarm/Diagnostics Documentation
Product • Alarm viewer
• Global functions • Menu guided • Rollerbed • Interfaces incl. Basic application
• * PRODIAG / Viewer • Documentation
* Operation modes
SICAR@TIAP
Plant Network
TPx00
WinCC RT Vx
PN/PN-Coupler
Standard und Safe
Communication
Profinet / ProfiSafe / TCP-IP Communication
ET200SP S7-151xF
Other lines
OM-Area
Scalance ET200SP
RB
Connection box
RB
Scalance
MCP
TT
OM-Area
Scalance ET200SP
EXH
Connection box
RB
EXH
QF
KTP900F
Scalance ET200SP RB
Plant Network
IPC 277x
WinCC RT Vx
PN/PN-Coupler
Standard und Safe
Communication
ET200SP S7-151xF Profinet / ProfiSafe / TCP-IP Communication
Other lines
Scalance Scanner
ET200SP
MCP Sinamics Schweisskoffer
Robot peripherie
(Welding guns, Handling etc.)
CP1604
Other application
(Glue control, ...)
and stat. Components
OM-Area (stat. Welding guns, cap changer, etc.)
Scanner
ET200SP
Schweisskoffer
Sinamics
CP1604
KTP900F
Scalance ET200SP
• Control ON/OFF
Centralized switch ON / OFF function of the control
• HMI
Management of HMI (IPC / Panels) and Push Button panels
Interface between HMI and PLC (prepared for 8 HMI)
• Operation mode management
Realize the management of operation modes
8 operation mode areas prepared
Each operation mode area can change operation mode (AUTO, Manual) independently
• Safety: Startup blocks
Example template for E-Stop and F_OUT with feedback control
Example template for an Euchner gate entry device
• Menu guidance
Headline and Footer
• Operation modes
• Pop Up technology
Legends
Operation modes
Auto / Manual / Single step
Control ON/OFF
Security dialogs
……..
• Overview screens
• Device ON / OFF
Tec-Unit to control the ON /OFF function of a device with feedback monitoring
• Lifter function
Tec-Unit to control a lifting device with 2 speeds, 2 directions and 2 positions
• Positioning devices
Tec-Unit to control a positioning device with 1 speed, 2 directions and 2 positions.
Tec-Unit to control a positioning device with 2 speeds, 2 directions and 2 positions.
Tec-Unit to control a positioning device with 2 speeds, 2 directions und 2 positions,
including part detection
• Valve control
Tec-Unit to control a valve with 1 cylinder.
Tec-Unit to control a valve with up to 8 cylinders.
• Drive
Interface to control a SINAMICS G120 drive
• Ident
Interface to control read / write functions of data from / to a RF tag.
• Production data
Support of production data (process counter, shift counter, cycle timers and limit values)
• Energy data
Interface to measure and display energy data via AI-EnergyMeter.
• PN Diagnostics (customized)
Diagnosis and visualization of PROFINet devices
• PLC Diagnostics (customized)
Read and visualize Identification and Maintenance data (I&M data) of the PLC
• System diagnostics (WinCC Control)
Overview about the available devices of the installation
• WEB-Server (WinCC Control)
HTML-Browser provides information about the status of all Webserver based devices
(Identification, diagnosis buffer, device status, messages, communication data and
topology data)
• Alarming (customized)
Multilingual alarm block package. It is possible to create own alarm texts which can be
activated with a trigger bit and displayed in the WinCC alarm control.
• Alarming (ProDiag)
Integrated Process Diagnostic based on ProDiag functionality
• Code viewer (WinCC Control)
Integrated Codeviewer for Process alarms and Graph
• Multilingual
Implemented languages are English and German
Additional languages can activated by user
RSS-Feed
RSS (Rich Site Summary) is a type of web feed which allows users to access updates to online content in a standardized, computer-readable format.
Websites usually use RSS feeds to publish frequently updated information, such as blog entries, news headlines, audio, video.
An RSS document (called "feed", "web feed" or "channel") includes full or summarized text, and metadata, like publishing date and author's name.
RSS-Feed in DiagAddOn
All entries in the message history are automatically stored in a XML-file and can be subscribed as an RSS-Feed.
• Sequence faults
• User messages (Message blocks)
• System messages DiagAddOn
Additional to each entry in the xml-file the system creates a txt-file.
Here you can find all conditions incl. criteria analysis for sequence fault or user message.
DiagGen
- Export of blocks and symbolic in XML-Format (TIA-Openness)
- Convert XML-> s7l, sdf für DiagAddOn
Return
to source
siemens.com/automotive