TIA Portal
Highlights of TIA Portal V17

WinCC Unified Hardware configuration TIA Portal Options


• Improved screen engineering with new style • Global Offline/Online comparison • OPC UA
• Graphics and faceplates (with functional enhancements) in • Offline/Offline comparison at parameter level S7-1200: Diagnostics, methods; S7-1500:
library • CPU 1518HF-4PN: Safety and redundancy Alarms and Conditions, Server modelling, Client:
• Extended quantity structures for S7-1500 and ET200 CPUs new Compact blocks, GDS – certificate handling
• Extended communication and 1st set of system diagnostic
• Extensions for CPU 1518 MFP  • PLCSIM/PLCSIM Advanced
• Audit for PC • Disable and enable I-Device Support of S7-1500 R/H CPU, secure communication with 
• WebClients for panel • DHCP and DNS for S7-1500 and ET200 CPUs OPC UA, OUC und HTTPS
• Plant Intelligence Options • Web server innovations • SIMATIC Target for Simulink
• S7-1200 Highlights with FW4.5 (OPC UA/Webserver) Code-generation for SIMATIC Edge & LiveTwin
• CPU 1518T/TF-4 PN/DP: High performance motion control Integrated S-functions for PLCSIM Adv coupling
WinCC – Innovations • Technology object DQ4_CAM • Test Suite
• WinCC Advanced: Openness Support of style guide Check
Template & Popup screens in the library System functions and application test
• SiVArc
• WinCC Professional: • Openness-extensions for libraries and UMAC
Support of WinCC Unified, new expressions, usability
Raw data for S7-1500, new system tags • User Management & Access Control (UMAC)
enhancements
• Library
• Energy Suite
STEP 7 – Innovations • Security per Default
Improved load management and flexible energy data
• CEM – Cause Effect Matrix • TIA Portal Language Packs
connections(by Proxy-DBs) 
• CFC – Continuous Function Chart (planned for July 2021) • Last used objects
• Central User Management (UMC)
• Download / Upload of user groups Single Sign-on, SIMATIC Logon-protocol, licensing
• Functional enhancements in the cross-reference list TIA Portal Options • Modular Application Creator
• Openness extensions for project generation • STEP 7 Safety • ProDiag
Fast Commissioning, nested UDTs, Monitoring within PLC Data Types,
Openness-extensions usability improvements
Startdrive – Innovations
• SIMATIC Safe Kinematics • Teamcenter Gateway
• Support of SINAMICS G115D Function, advantages and requirements Single Sign-on, PKI, Linking
• S120: Data set switching, manual optimization • Multiuser between Teamcenter and TIA Portal objects
• SINAMICS DCC: Know-how-protection SIMATIC Robot Library

Page 2 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal
Highlights of TIA Portal V17

WinCC Unified Hardware configuration TIA Portal Options


• Improved screen engineering with new style • Global Offline/Online comparison • OPC UA
• Graphics and faceplates (with functional enhancements) in • Offline/Offline comparison at parameter level S7-1200: Diagnostics, methods; S7-1500:
library • CPU 1518HF-4PN: Safety and redundancy Alarms and Conditions, Server modelling, Client:
• Extended quantity structures for S7-1500 and ET200 CPUs new Compact blocks, GDS – certificate handling
• Extended communication and 1st set of system diagnostic
• Extensions for CPU 1518 MFP  • PLCSIM/PLCSIM Advanced
• Audit for PC • Disable and enable I-Device Support of S7-1500 R/H CPU, secure communication with 
• WebClients for panel • DHCP and DNS for S7-1500 and ET200 CPUs OPC UA, OUC und HTTPS
• Plant Intelligence Options • Web server innovations • SIMATIC Target for Simulink
• S7-1200 Highlights with FW4.5 (OPC UA/Webserver) Code-generation for SIMATIC Edge & LiveTwin
• CPU 1518T/TF-4 PN/DP: High performance motion control Integrated S-functions for PLCSIM Adv coupling
WinCC – Innovations • Technology object DQ4_CAM • Test Suite
• WinCC Advanced: Openness Support of style guide Check
Template & Popup screens in the library System functions and application test
• SiVArc
• WinCC Professional: • Openness-extensions for libraries and UMAC
Support of WinCC Unified, new expressions, usability
Raw data for S7-1500, new system tags • User Management & Access Control (UMAC)
enhancements
• Library
• Energy Suite
STEP 7 – Innovations • Security per Default
Improved load management and flexible energy data
• CEM – Cause Effect Matrix • TIA Portal Language Packs
connections(by Proxy-DBs) 
• CFC – Continuous Function Chart (planned for July 2021) • Last used objects
• Central User Management (UMC)
• Download / Upload of user groups Single Sign-on, SIMATIC Logon-protocol, licensing
• Functional enhancements in the cross-reference list TIA Portal Options • Modular Application Creator
• Openness extensions for project generation • STEP 7 Safety • ProDiag
Fast Commissioning, nested UDTs, Monitoring within PLC Data Types,
Openness-extensions usability improvements
Startdrive – Innovations
• SIMATIC Safe Kinematics • Teamcenter Gateway
• Support of SINAMICS G115D Function, advantages and requirements Single Sign-on, PKI, Linking
• S120: Data set switching, manual optimization • Multiuser between Teamcenter and TIA Portal objects
• SINAMICS DCC: Know-how-protection SIMATIC Robot Library

Page 39 Unrestricted | © Siemens 2021 | DI FA | May 2021


STEP 7 – innovations
General extended functions

Cross-reference filter Cross-reference list in the Inspector window Cross-reference editor


User-defined filter supports inputs, outputs and bit 1. Freezing of current cross-reference display Improved visualization of overlapping input
memories. 2. Display of high-level accesses with structure tags and output addresses.
(struct, UDT)

1
2

Page 43 Unrestricted | © Siemens 2021 | DI FA | May 2021


STEP 7 – innovations
General extended functions

Ignore inverted commas in Partial search for block names Display of "Published" block property in
"Open block" dialog (F7) in "Open block" dialog (F7) project tree
This allows block names to be copied straight from Block search without entering prefix in The "Published" property is visualized in the project tree
an editor to the "Open block" dialog, "Open block" dialog. itself for blocks, PLC data types (UDT) and
where they can then be opened. PLC tag tables within software units.

Page 44 Unrestricted | © Siemens 2021 | DI FA | May 2021


STEP 7 – innovations
General extended functions

Number of replacements Simplified search with "Ctrl + F" Downloading data blocks
The total number of replacements is displayed for local In many STEP 7 editors, "Ctrl + F" can be used to copy As of V17, data blocks are not re-initialized during loading
Find & Replace. the marked text straight into the Find box of the local until their structure has actually changed (<V17 interface
search function. A second "Ctrl + F" copies the search timestamp).
text to the global search.
This enables a subsequent download without re-
initialization when generating data blocks with an identical
structure via Openness/VCI/ASCII sources.

Page 45 Unrestricted | © Siemens 2021 | DI FA | May 2021


STEP 7 – Innovationen
General extended functions

Improved line break at variable names Synchronisation at tag Import More one-finger keyboard shortcuts
In LAD, FBD, GRAPH and CEM, at operands written in When importing PLC tag tables, e.g. from Microsoft The keyboard shortcuts for LAD (empty box, normally
"camelCasing" or "PascalCasing" a line break is inserted Excel, it is possible to decide whether to synchronize by closed, normally open) and FBD (empty box, AND, OR)
before an uppercase letter if possible. name or address. This makes it easy to distinguish can now be operated with one finger (F8, F9, F10).
between renaming or rewiring.

Bis V16 V17

Page 46 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal
Highlights of TIA Portal V17

WinCC Unified Hardware configuration TIA Portal Options


• Improved screen engineering with new style • Global Offline/Online comparison • OPC UA
• Graphics and faceplates (with functional enhancements) in • Offline/Offline comparison at parameter level S7-1200: Diagnostics, methods; S7-1500:
library • CPU 1518HF-4PN: Safety and redundancy Alarms and Conditions, Server modelling, Client:
• Extended quantity structures for S7-1500 and ET200 CPUs new Compact blocks, GDS – certificate handling
• Extended communication and 1st set of system diagnostic
• Extensions for CPU 1518 MFP  • PLCSIM/PLCSIM Advanced
• Audit for PC • Disable and enable I-Device Support of S7-1500 R/H CPU, secure communication with 
• WebClients for panel • DHCP and DNS for S7-1500 and ET200 CPUs OPC UA, OUC und HTTPS
• Plant Intelligence Options • Web server innovations • SIMATIC Target for Simulink
• S7-1200 Highlights with FW4.5 (OPC UA/Webserver) Code-generation for SIMATIC Edge & LiveTwin
• CPU 1518T/TF-4 PN/DP: High performance motion control Integrated S-functions for PLCSIM Adv coupling
WinCC – Innovations • Technology object DQ4_CAM • Test Suite
• WinCC Advanced: Openness Support of style guide Check
Template & Popup screens in the library System functions and application test
• SiVArc
• WinCC Professional: • Openness-extensions for libraries and UMAC
Support of WinCC Unified, new expressions, usability
Raw data for S7-1500, new system tags • User Management & Access Control (UMAC)
enhancements
• Library
• Energy Suite
STEP 7 – Innovations • Security per Default
Improved load management and flexible energy data
• CEM – Cause Effect Matrix • TIA Portal Language Packs
connections(by Proxy-DBs) 
• CFC – Continuous Function Chart (planned for July 2021) • Last used objects
• Central User Management (UMC)
• Download / Upload of user groups Single Sign-on, SIMATIC Logon-protocol, licensing
• Functional enhancements in the cross-reference list TIA Portal Options • Modular Application Creator
• Openness extensions for project generation • STEP 7 Safety • ProDiag
Fast Commissioning, nested UDTs, Monitoring within PLC Data Types,
Openness-extensions usability improvements
Startdrive – Innovations
• SIMATIC Safe Kinematics • Teamcenter Gateway
• Support of SINAMICS G115D Function, advantages and requirements Single Sign-on, PKI, Linking
• S120: Data set switching, manual optimization • Multiuser between Teamcenter and TIA Portal objects
• SINAMICS DCC: Know-how-protection SIMATIC Robot Library

Page 49 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal – hardware configuration
Global offline/online comparison

Function
Comparison of compiled offline hardware configuration in TIA Portal with the online
hardware configuration on the device:
• Quick overview
• Distributed I/O for the PLC is taken into account
• Based on checksums and takes user inputs into account

Application
• Offline and online configurations are identical
• Offline and online configurations differ
• User inputs and compiled offline configuration differ:
• Compiling the hardware configuration to apply changes
• Unintentional inputs: "Undo" or re-open project

New

Page 50 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal – hardware configuration
Offline/offline comparison at parameter level

Function
Comparison of two offline configurations at parameter level
• Allows the comparison of PLCs including connected centralized/distributed I/O
• Ideal for comparing the current configuration with a reference configuration
New • An indirect offline/online comparison of the configuration at parameter level is
possible using the intermediate step "Upload"
Note
Intended extensions:
• Filter options
• Assignment of parameters
• Supports further modules

Page 51 Unrestricted | © Siemens 2021 | DI FA | May 2021


SIMATIC S7-1500-/ET 200-CPUs
General web server extensions

Memory display for data types

Benefits of the function


Data types occupy resources in the CPU's memory. Displaying data type resource
consumption prevents the situation where the user program can no longer be
loaded onto the controller because of insufficient memory capacity.

Page 62 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal – System functions
Recently used objects

New functions
Open recently used objects
• The menu command "Edit > Open recent object" shows the 20 last used objects
in the order of their last use in TIA Portal
• The view of the list is related to the currently active scope, e.g. to a navigation
view or the editor used
• The lists are available for the following areas:
• Projects and Project Libraries
• Global Libraries
• Multiuser local sessions and server view
• Reference projects

• The menu command "Clear list" removes all entries from the list
• The list of recently used objects is linked to the Windows user profile. Thus, the
list is retained even after the TIA Portal has been closed

Page 87 Unrestricted | © Siemens 2021 | DI FA | May 2021


System functions
Spare parts compatibility S7-1500 and ET 200 CPUs – FW 2.9 with older TIA
Portal versions

TIA Portal V12 to TIA Portal V16 TIA Portal V17 

V12/V13/V13 SP1 V14/V14 SP1 V15/V15.1 V16 V17 project


project with project with project with project with FW 2.9
FW 1.0 to FW/1.8 FW 2.0/2.1 FW 2.5/FW 2.6 with FW 2.8

Firmware V2.9 Firmware V2.9 Firmware V2.9 Firmware V2.9 Firmware V2.9

New functions can be used with TIA


Full spare part functionality: Online support: ID 109744163
Portal V17 and firmware V2.9

Page 90 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – Info compatibilité
System functions
TIA Portal Openness – compatibility

Compatibility with predecessor versions


• The Openness DLLs from V15, V15.1 and V16 are
Openness
application supplied with TIA Portal V17 in addition to the new V17 DLL
V17
• This allows use in the new TIA Portal environment
of Openness applications created on the basis of an
Openness Openness
older version of TIA Portal
application application
• The new Openness functions are only
V15 V15
available in the most recent DLL
• Openness applications based on V14 SP1 are
Openness
application
Openness
application
no longer supported with V17
V14 SP1 V14 SP1

.NET Framework 4.8


TIA Portal TIA Portal TIA Portal TIA Portal TIA Portal
V14 SP1 V15 V15.1 V16 • With TIA Portal V17, the .Net Framework is upgraded to 4.8
V17
• Existing, compiled Openness applications based on .NET
V14 V14
V15
V14
V15 V15.1
V14
V15 V15.1 V16
V14
V15 V15.1 V16 V17
Framework 4.6.x still run with .NET Framework 4.8
SP1 SP1 SP1 SP1 SP1
DLL DLL DLL DLL DLL DLL DLL DLL DLL DLL
DLL DLL DLL DLL DLL

.NET Framework 4.6.2 .NET Framework 4.8

Page 91 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – à étudier (MAJ auto des projets)
System functions
TIA Portal Openness – library

Automated library workflows


The following library functions can now be controlled using an
Openness application:
• Apply the structure when updating the library
• Clean up library
• Harmonize project

TIA Benefits
Portal The complete range of workflows for library and project updates can be performed
using an Openness application with the new library Openness function.
Openness This enables the efficient, automated rollout of an updated library to TIA Portal
projects.

Page 92 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – fonction à étudier
System functions
TIA Portal User Management & Access Control (UMAC)

New engineering function rights


The following user actions can be restricted by the new function rights:
• General function rights: Edit library types, edit hardware configuration, edit
Configuration of project via Openness API, import project texts, upgrade project
user-roles
• PLC: Download, edit program, edit safety, monitor, modify online

• HMI: Download, configure, perform device maintenance


Restricts actions and
changes in editors • Drives: Download, edit drive configuration

Benefits
The previous access protection for the TIA Portal project differentiated between
read and write access.

With the new function rights, user roles can now be adjusted even more
specifically to responsibilities.

In engineering, this protects numerous actions and workflows against unauthorized


users.

Page 99 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – fonction à étudier
System functions
TIA Portal User Management & Access Control (UMAC)

Locking a project
• An open project can be protected against editing by locking it

• Locking a project can be activated manually or automatically after a


configurable period of inactivity

Benefits
When an operator temporarily leaves the engineering station, locking the project
prevents editing without having to close it.
You leave the station – project gets locked!

Changing the user 


• Menu entry for changing the user in an open project

Benefits
The "Change user" function allows work on the project to continue in the same
place in the project after a change of user.
You need elevated rights – change the user!

Page 100 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – fonction à étudier
System functions
TIA Portal User Management & Access Control (UMAC)

Anonymous user
• This specific type of user requires no authentication
• It can be explicitly activated/deactivated

You want to open a protected project without authentication – • Roles/function rights can be assigned

activate the Anonymous user! Benefits


A protected project can be opened with the assigned rights by activating the
anonymous user without entering a password.

Standard login procedure


• The login procedure to be used when opening a protected project can be
selected in the TIA Portal settings
• You can choose from: Login via the TIA Portal login dialog for user name and
password, login as anonymous user and login using the single sign-on session

You want to open a protected project without login dialog – Benefits


preselect authentication method! Using the login procedure for anonymous users or single sign-on, a protected
project can be opened without explicit user authentication.

Page 101 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal
Highlights of TIA Portal V17

WinCC Unified Hardware configuration TIA Portal Options


• Improved screen engineering with new style • Global Offline/Online comparison • OPC UA
• Graphics and faceplates (with functional enhancements) in • Offline/Offline comparison at parameter level S7-1200: Diagnostics, methods; S7-1500:
library • CPU 1518HF-4PN: Safety and redundancy Alarms and Conditions, Server modelling, Client:
• Extended quantity structures for S7-1500 and ET200 CPUs new Compact blocks, GDS – certificate handling
• Extended communication and 1st set of system diagnostic
• Extensions for CPU 1518 MFP  • PLCSIM/PLCSIM Advanced
• Audit for PC • Disable and enable I-Device Support of S7-1500 R/H CPU, secure communication with 
• WebClients for panel • DHCP and DNS for S7-1500 and ET200 CPUs OPC UA, OUC und HTTPS
• Plant Intelligence Options • Web server innovations • SIMATIC Target for Simulink
• S7-1200 Highlights with FW4.5 (OPC UA/Webserver) Code-generation for SIMATIC Edge & LiveTwin
• CPU 1518T/TF-4 PN/DP: High performance motion control Integrated S-functions for PLCSIM Adv coupling
WinCC – Innovations • Technology object DQ4_CAM • Test Suite
• WinCC Advanced: Openness Support of style guide Check
Template & Popup screens in the library System functions and application test
• SiVArc
• WinCC Professional: • Openness-extensions for libraries and UMAC
Support of WinCC Unified, new expressions, usability
Raw data for S7-1500, new system tags • User Management & Access Control (UMAC)
enhancements
• Library
• Energy Suite
STEP 7 – Innovations • Security per Default
Improved load management and flexible energy data
• CEM – Cause Effect Matrix • TIA Portal Language Packs
connections(by Proxy-DBs) 
• CFC – Continuous Function Chart (planned for July 2021) • Last used objects
• Central User Management (UMC)
• Download / Upload of user groups Single Sign-on, SIMATIC Logon-protocol, licensing
• Functional enhancements in the cross-reference list TIA Portal Options • Modular Application Creator
• Openness extensions for project generation • STEP 7 Safety • ProDiag
Fast Commissioning, nested UDTs, Monitoring within PLC Data Types,
Openness-extensions usability improvements
Startdrive – Innovations
• SIMATIC Safe Kinematics • Teamcenter Gateway
• Support of SINAMICS G115D Function, advantages and requirements Single Sign-on, PKI, Linking
• S120: Data set switching, manual optimization • Multiuser between Teamcenter and TIA Portal objects
• SINAMICS DCC: Know-how-protection SIMATIC Robot Library

Page 139 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – à étudier
TIA Portal Test Suite Advanced V17
Extended functions

Export/import of rule sets/test cases Shortcut menu in the application test Further improvements
Export/import of rules sets and test cases using the
editor Style guide:
shortcut menu in the PNV editor. Shortcut menu for copying, cutting and collapsing test • Author, version number and comment can be
cases in the test case editor.
added to a rule set

• New rule for checking, whether a comment exists


for variables and block parameters

Application test:

• Application test supports now ET 200pro, S7-1500


R/H and SIMATIC Drive Controller

• New "Assert.InRange (variable, lowerBound,


upperBound)" instruction for integer and real
variables

• Commenting out of single/multiple lines in the test


case editor using the toolbar.

Page 141 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal
Highlights of TIA Portal V17

WinCC Unified Hardware configuration TIA Portal Options


• Improved screen engineering with new style • Global Offline/Online comparison • OPC UA
• Graphics and faceplates (with functional enhancements) in • Offline/Offline comparison at parameter level S7-1200: Diagnostics, methods; S7-1500:
library • CPU 1518HF-4PN: Safety and redundancy Alarms and Conditions, Server modelling, Client:
• Extended quantity structures for S7-1500 and ET200 CPUs new Compact blocks, GDS – certificate handling
• Extended communication and 1st set of system diagnostic
• Extensions for CPU 1518 MFP  • PLCSIM/PLCSIM Advanced
• Audit for PC • Disable and enable I-Device Support of S7-1500 R/H CPU, secure communication with 
• WebClients for panel • DHCP and DNS for S7-1500 and ET200 CPUs OPC UA, OUC und HTTPS
• Plant Intelligence Options • Web server innovations • SIMATIC Target for Simulink
• S7-1200 Highlights with FW4.5 (OPC UA/Webserver) Code-generation for SIMATIC Edge & LiveTwin
• CPU 1518T/TF-4 PN/DP: High performance motion control Integrated S-functions for PLCSIM Adv coupling
WinCC – Innovations • Technology object DQ4_CAM • Test Suite
• WinCC Advanced: Openness Support of style guide Check
Template & Popup screens in the library System functions and application test
• SiVArc
• WinCC Professional: • Openness-extensions for libraries and UMAC
Support of WinCC Unified, new expressions, usability
Raw data for S7-1500, new system tags • User Management & Access Control (UMAC)
enhancements
• Library
• Energy Suite
STEP 7 – Innovations • Security per Default
Improved load management and flexible energy data
• CEM – Cause Effect Matrix • TIA Portal Language Packs
connections(by Proxy-DBs) 
• CFC – Continuous Function Chart (planned for July 2021) • Last used objects
• Central User Management (UMC)
• Download / Upload of user groups Single Sign-on, SIMATIC Logon-protocol, licensing
• Functional enhancements in the cross-reference list TIA Portal Options • Modular Application Creator
• Openness extensions for project generation • STEP 7 Safety • ProDiag
Fast Commissioning, nested UDTs, Monitoring within PLC Data Types,
Openness-extensions usability improvements
Startdrive – Innovations
• SIMATIC Safe Kinematics • Teamcenter Gateway
• Support of SINAMICS G115D Function, advantages and requirements Single Sign-on, PKI, Linking
• S120: Data set switching, manual optimization • Multiuser between Teamcenter and TIA Portal objects
• SINAMICS DCC: Know-how-protection SIMATIC Robot Library

Page 147 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – à étudier
Central user management (UMC)
Overview of new functions (from UMC V2.9 SP3)

SIMATIC Logon support


UMC SIMATIC • The UMC server supports the SIMATIC Logon protocol
Server Logon
• This enables central user management for WinCC Runtime Advanced and
protocol
… Comfort Panels via UMC

Benefits
Integration of the SIMATIC Logon protocol enables use of an existing HMI Runtime
system within a UMC domain.

WinCC
TIA Portal
Advanced
engineering
Runtime
Single sign-on (SSO)
• TIA Portal and HMI Runtimes support the connection to single sign-on

WinCC Unified
SIMATIC Benefits
Runtime SSO Comfort
Single sign-on enables seamless authentication between a protected TIA Portal
Panels
project and an HMI Runtime on the same operator station. Once authenticated, the
application can take over the existing single sign-on user session.

Page 148 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – à étudier
Central user management (UMC)
Licensing

License model
UMC • The User Management Component (UMC) is included in the products' scope of
Ring server/domain supply
Active …
directory • The license model depends on the number of user accounts per UMC domain

• Up to ten user accounts can be created without a license


• Additional 100 user accounts as 365-day license
• Article number: 6ES7823-1UE30-0YA0
• Additional 4000 user accounts as 365-day license
Device/ Device/ • Article number: 6ES7823-1UE10-0YA0
application application
• The licenses can be accumulated

Benefits
Device/ Device/
• First steps possible without license costs
application application • Appropriate license for low number of user accounts
• Flexible expandability with accumulative licenses
Device/ • Flexible adjustment thanks to limited license period
application

Page 149 Unrestricted | © Siemens 2021 | DI FA | May 2021


TIA Portal
Highlights of TIA Portal V17

WinCC Unified Hardware configuration TIA Portal Options


• Improved screen engineering with new style • Global Offline/Online comparison • OPC UA
• Graphics and faceplates (with functional enhancements) in • Offline/Offline comparison at parameter level S7-1200: Diagnostics, methods; S7-1500:
library • CPU 1518HF-4PN: Safety and redundancy Alarms and Conditions, Server modelling, Client:
• Extended quantity structures for S7-1500 and ET200 CPUs new Compact blocks, GDS – certificate handling
• Extended communication and 1st set of system diagnostic
• Extensions for CPU 1518 MFP  • PLCSIM/PLCSIM Advanced
• Audit for PC • Disable and enable I-Device Support of S7-1500 R/H CPU, secure communication with 
• WebClients for panel • DHCP and DNS for S7-1500 and ET200 CPUs OPC UA, OUC und HTTPS
• Plant Intelligence Options • Web server innovations • SIMATIC Target for Simulink
• S7-1200 Highlights with FW4.5 (OPC UA/Webserver) Code-generation for SIMATIC Edge & LiveTwin
• CPU 1518T/TF-4 PN/DP: High performance motion control Integrated S-functions for PLCSIM Adv coupling
WinCC – Innovations • Technology object DQ4_CAM • Test Suite
• WinCC Advanced: Openness Support of style guide Check
Template & Popup screens in the library System functions and application test
• SiVArc
• WinCC Professional: • Openness-extensions for libraries and UMAC
Support of WinCC Unified, new expressions, usability
Raw data for S7-1500, new system tags • User Management & Access Control (UMAC)
enhancements
• Library
• Energy Suite
STEP 7 – Innovations • Security per Default
Improved load management and flexible energy data
• CEM – Cause Effect Matrix • TIA Portal Language Packs
connections(by Proxy-DBs) 
• CFC – Continuous Function Chart (planned for July 2021) • Last used objects
• Central User Management (UMC)
• Download / Upload of user groups Single Sign-on, SIMATIC Logon-protocol, licensing
• Functional enhancements in the cross-reference list TIA Portal Options • Modular Application Creator
• Openness extensions for project generation • STEP 7 Safety • ProDiag
Fast Commissioning, nested UDTs, Monitoring within PLC Data Types,
Openness-extensions usability improvements
Startdrive – Innovations
• SIMATIC Safe Kinematics • Teamcenter Gateway
• Support of SINAMICS G115D Function, advantages and requirements Single Sign-on, PKI, Linking
• S120: Data set switching, manual optimization • Multiuser between Teamcenter and TIA Portal objects
• SINAMICS DCC: Know-how-protection SIMATIC Robot Library

Page 158 Unrestricted | © Siemens 2021 | DI FA | May 2021


Métier – à étudier
Teamcenter Gateway
Single sign-on and smart card (PKI) support

TIA Portal V17 Single sign-on and smart card (PKI) support
• Supports a secure connection between TIA Portal and Teamcenter via "single
sign-on" (SSO)
• Authentication by means of customized smart card (PKI)
Teamcenter
Benefits
PKI server1
• Secure connection between TIA Portal and Teamcenter
• High level of usability thanks to SSO authentication of the Teamcenter clients1
on the Teamcenter server
• Use of company's own smart cards with PKI simplifies password handling and
increases security

Rich Application
Client (RAC)
SSO

Client Active workspace


website/app client

1
With SSO support

Page 159 Unrestricted | © Siemens 2021 | DI FA | May 2021


Teamcenter Gateway
Link between Teamcenter and TIA Portal objects

PLC program blocks changed Link between Teamcenter and TIA Portal objects (Program
Machine upgraded in plant
in engineering workstation
blocks, UDTs and OPC UA server interfaces)
• Central activation/deactivation of the export of TIA Portal objects
(as proxy objects) to Teamcenter
• Joint export of the TIA Portal project together with the proxy objects
as new Teamcenter elements
• Creation of proxy object revisions
• Navigating and opening TIA Portal blocks and UDTs directly
from Teamcenter
• Customizable tool to perform bulk linking of TIA Portal proxy objects and
Teamcenter RAC 12.2 and higher Teamcenter elements. The tool is available in SIOS (Siemens Information
Online System)
Export TIA proxy objects
(save as new item/revision)
PB-1 A1 Benefits
PB-2 A2 • Teamcenter artefacts (such as a motor) can be directly linked to the
PB-3 A3
associated function blocks or UDTs  thus supporting consistent project
management
PB-4 A4
OPC UA Server
• Fast and simple tracking of changes
A5
TIA V17.00 Interfaces • Fast and secure navigation of Teamcenter artefacts to the associated
… … TIA Portal objects
TIA proxy objects
Teamcenter • Reduction of engineering time through automated linking of TIA Portal proxy
Navigate and open FBs, FCs and artifacts
UDTs in TIA Portal
objects and Teamcenter elements

Page 160 Unrestricted | © Siemens 2021 | DI FA | May 2021


Contact
Published by Siemens AG
www.siemens.com/ta-portal

Page 161 Unrestricted | © Siemens 2021 | DI FA | May 2021


Disclaimer

© Siemens 2021

Subject to changes and errors. The information given in this document


only contains general descriptions and/or performance features which
may not always specifically reflect those described, or which may
undergo modification in the course of further development of the
products. The requested performance features are binding only when
they are expressly agreed upon in the concluded contract.

All product designations may be trademarks or other rights of


Siemens AG, its affiliated companies or other companies whose use by
third parties for their own purposes could violate the rights of the
respective owner.

Page 162 Unrestricted | © Siemens 2021 | DI FA | May 2021

You might also like