Highlights
May 2021
1
2
Ignore inverted commas in Partial search for block names Display of "Published" block property in
"Open block" dialog (F7) in "Open block" dialog (F7) project tree
This allows block names to be copied straight from Block search without entering prefix in The "Published" property is visualized in the project tree
an editor to the "Open block" dialog, "Open block" dialog. itself for blocks, PLC data types (UDT) and
where they can then be opened. PLC tag tables within software units.
Number of replacements Simplified search with "Ctrl + F" Downloading data blocks
The total number of replacements is displayed for local In many STEP 7 editors, "Ctrl + F" can be used to copy As of V17, data blocks are not re-initialized during loading
Find & Replace. the marked text straight into the Find box of the local until their structure has actually changed (<V17 interface
search function. A second "Ctrl + F" copies the search timestamp).
text to the global search.
This enables a subsequent download without re-
initialization when generating data blocks with an identical
structure via Openness/VCI/ASCII sources.
Improved line break at variable names Synchronisation at tag Import More one-finger keyboard shortcuts
In LAD, FBD, GRAPH and CEM, at operands written in When importing PLC tag tables, e.g. from Microsoft The keyboard shortcuts for LAD (empty box, normally
"camelCasing" or "PascalCasing" a line break is inserted Excel, it is possible to decide whether to synchronize by closed, normally open) and FBD (empty box, AND, OR)
before an uppercase letter if possible. name or address. This makes it easy to distinguish can now be operated with one finger (F8, F9, F10).
between renaming or rewiring.
Function
Comparison of compiled offline hardware configuration in TIA Portal with the online
hardware configuration on the device:
• Quick overview
• Distributed I/O for the PLC is taken into account
• Based on checksums and takes user inputs into account
Application
• Offline and online configurations are identical
• Offline and online configurations differ
• User inputs and compiled offline configuration differ:
• Compiling the hardware configuration to apply changes
• Unintentional inputs: "Undo" or re-open project
New
Function
Comparison of two offline configurations at parameter level
• Allows the comparison of PLCs including connected centralized/distributed I/O
• Ideal for comparing the current configuration with a reference configuration
New • An indirect offline/online comparison of the configuration at parameter level is
possible using the intermediate step "Upload"
Note
Intended extensions:
• Filter options
• Assignment of parameters
• Supports further modules
New functions
Open recently used objects
• The menu command "Edit > Open recent object" shows the 20 last used objects
in the order of their last use in TIA Portal
• The view of the list is related to the currently active scope, e.g. to a navigation
view or the editor used
• The lists are available for the following areas:
• Projects and Project Libraries
• Global Libraries
• Multiuser local sessions and server view
• Reference projects
• The menu command "Clear list" removes all entries from the list
• The list of recently used objects is linked to the Windows user profile. Thus, the
list is retained even after the TIA Portal has been closed
Firmware V2.9 Firmware V2.9 Firmware V2.9 Firmware V2.9 Firmware V2.9
TIA Benefits
Portal The complete range of workflows for library and project updates can be performed
using an Openness application with the new library Openness function.
Openness This enables the efficient, automated rollout of an updated library to TIA Portal
projects.
Benefits
The previous access protection for the TIA Portal project differentiated between
read and write access.
With the new function rights, user roles can now be adjusted even more
specifically to responsibilities.
Locking a project
• An open project can be protected against editing by locking it
Benefits
When an operator temporarily leaves the engineering station, locking the project
prevents editing without having to close it.
You leave the station – project gets locked!
Benefits
The "Change user" function allows work on the project to continue in the same
place in the project after a change of user.
You need elevated rights – change the user!
Anonymous user
• This specific type of user requires no authentication
• It can be explicitly activated/deactivated
You want to open a protected project without authentication – • Roles/function rights can be assigned
Export/import of rule sets/test cases Shortcut menu in the application test Further improvements
Export/import of rules sets and test cases using the
editor Style guide:
shortcut menu in the PNV editor. Shortcut menu for copying, cutting and collapsing test • Author, version number and comment can be
cases in the test case editor.
added to a rule set
Application test:
Benefits
Integration of the SIMATIC Logon protocol enables use of an existing HMI Runtime
system within a UMC domain.
WinCC
TIA Portal
Advanced
engineering
Runtime
Single sign-on (SSO)
• TIA Portal and HMI Runtimes support the connection to single sign-on
WinCC Unified
SIMATIC Benefits
Runtime SSO Comfort
Single sign-on enables seamless authentication between a protected TIA Portal
Panels
project and an HMI Runtime on the same operator station. Once authenticated, the
application can take over the existing single sign-on user session.
License model
UMC • The User Management Component (UMC) is included in the products' scope of
Ring server/domain supply
Active …
directory • The license model depends on the number of user accounts per UMC domain
…
Benefits
Device/ Device/
• First steps possible without license costs
application application • Appropriate license for low number of user accounts
• Flexible expandability with accumulative licenses
Device/ • Flexible adjustment thanks to limited license period
application
TIA Portal V17 Single sign-on and smart card (PKI) support
• Supports a secure connection between TIA Portal and Teamcenter via "single
sign-on" (SSO)
• Authentication by means of customized smart card (PKI)
Teamcenter
Benefits
PKI server1
• Secure connection between TIA Portal and Teamcenter
• High level of usability thanks to SSO authentication of the Teamcenter clients1
on the Teamcenter server
• Use of company's own smart cards with PKI simplifies password handling and
increases security
Rich Application
Client (RAC)
SSO
1
With SSO support
PLC program blocks changed Link between Teamcenter and TIA Portal objects (Program
Machine upgraded in plant
in engineering workstation
blocks, UDTs and OPC UA server interfaces)
• Central activation/deactivation of the export of TIA Portal objects
(as proxy objects) to Teamcenter
• Joint export of the TIA Portal project together with the proxy objects
as new Teamcenter elements
• Creation of proxy object revisions
• Navigating and opening TIA Portal blocks and UDTs directly
from Teamcenter
• Customizable tool to perform bulk linking of TIA Portal proxy objects and
Teamcenter RAC 12.2 and higher Teamcenter elements. The tool is available in SIOS (Siemens Information
Online System)
Export TIA proxy objects
(save as new item/revision)
PB-1 A1 Benefits
PB-2 A2 • Teamcenter artefacts (such as a motor) can be directly linked to the
PB-3 A3
associated function blocks or UDTs thus supporting consistent project
management
PB-4 A4
OPC UA Server
• Fast and simple tracking of changes
A5
TIA V17.00 Interfaces • Fast and secure navigation of Teamcenter artefacts to the associated
… … TIA Portal objects
TIA proxy objects
Teamcenter • Reduction of engineering time through automated linking of TIA Portal proxy
Navigate and open FBs, FCs and artifacts
UDTs in TIA Portal
objects and Teamcenter elements
© Siemens 2021