Chapitre 1 Introduction
General View
Chapitre 4
Chapitre 5 Configuration of Plant
BASIC - 1 2
INTRODUCTION
The purpose of this session is to provide an overview of the 1131.1 MW RAS-DJINET DE Combined Cycle
Power Plant.
The RAS DJINET plant consists of three (3) single-shaft combined cycle power plant (CCPP) modules as
well as Balance of Plant (BOP) Equipment.
Each module of the CCPP has one (1) gas turbine (model: SIEMENS SGT5-4000F), one (1) associated
HRSG, one (1) steam turbine (Model: SIEMENS SST5-3000 H-IL ) and a common hydrogen-cooled
generator (Model: SIEMENS SGEN 5-2000 H) located on the same shaft between the gas turbine (GT) and
the steam turbine (ST).
Gas turbines are designed to burn natural gas as the base fuel and diesel fuel as the backup fuel.
BASIC - 1 3
OPERATING PARAMETERS
• Reference Conditions
− Ambient Temperature : 35 0C
− Frequency : 50 Hz
− Cycle Make-up : 0%
BASIC - 1 4
OPERATING PARAMETERS
• Various Plant operating parameters at above reference conditions and at 100% load are as follows.
Description Units With Natural Gas Firing With Oil Firing
Net Power Output of each block MW 377 311.3
Net Plant Heat Rate KJ/Kwh 6165 6599
Gas turbine Power Output MW 249.2 210.5
Steam Turbine Power Output MW 127.8 100.8
Fuel Consumption kg/s 14.3 13.24
Exhaust gas temperature 0
C 607.6 557.4
Exhaust gas flow kg/s 616.2 610.9
HP Super Heater Outlet Pressure Bar (a) 120.81 101.81
HP Superheater Outlet Temperature 0
C 566.50 530.10
HP Steam Turbine Inlet Pressure Bar (a) 117.92 99.39
HP Steam Turbine Inlet Temperature 0
C 565.02 528.27
BASIC - 1 5
OPERATING PARAMETERS
Description Units With Natural Gas Firing With Oil Firing
HP Steam Flow kg/s 71.99 61.66
Reheater Outlet Pressure Bar (a) 29.91 25.91
Reheater Outlet Temperature C
0
565.70 526.20
IP Steam Turbine Inlet Pressure Bar (a) 29.10 25.20
IP Steam Inlet Turbine C
0
564.94 524.99
Temperature
IP Steam Flow kg/s 71.99 76.02
IP Superheater Outlet Pressure Bar (a) 31.31 27.11
IP Superheater Outlet Temperature C
0
337.50 324.30
LP Superheater Outlet Pressure Bar (a) 4.51 4.21
LP Superheater Outlet Temperature C
0
232.60 237.70
LP Superheater Outlet Steam Flow kg/s 10.14 2.58
LP Turbine Exhaust Flow kg/s 98.25 80.31
LP Turbine Exhaust Temperature C
0
33.35 31.56
BASIC - 1 6
OPERATING PARAMETERS
Description Units Parameters (With Natural Gas Parameters (With Oil Firing)
Firing)
HP Economizer Inlet Flow Kg/s 71.99 61.66
IP Economizer Inlet Flow Kg/s 23.57 17.03
Condenser Back Pressure Bar (a) 0.0514 0.0464
Condenser Cooling Water Inlet C
0
24 24
Temperature
Condenser Cooling Water Outlet C
0
30 28.63
Temperature
BASIC - 1 7
GENERAL DESCRIPTION OF CCPP
EXISTING
EXISTING
BASIC - 1 8
GENERAL DESCRIPTION OF CCPP
VIEW OF RDPP
EXISTING POWER PLANT
UNIT#70 UNIT#60 UNIT#50
400 kV GIS
BASIC - 1 9
GENERAL DESCRIPTION OF CCPP – VIEW OF ST, GENERATOR, GT & HRSG
Condensor
Chimney
BASIC - 1 10
GENERAL VIEW (GAS TURBINE -GENERSTOR – STEAM TURBINE)
AIR INLET
STEAM FILTER
GENERAL VIEW OF ONE
TURBINE
UNIT (GAS TURBINE -
GENERSTOR – STEAM
TURBINE ETC.)
GAS
TURBINE
GENERATOR
TO
HRSG
BASIC - 1 11
GENERAL VIEW (GAS TURBINE -GENERSTOR – STEAM TURBINE)
CLUTCH
TURBINE À GAZ
TURBINE À VAPEUR
(HP)
BASIC - 1 13
PLANT CONFIGURATION
BASIC - 1 14
PLANT CONFIGURATION
BASIC - 1 15
MAIN EQUIPMENT
Followings are the Main Equipment of CCPP
BASIC - 1 16
MAIN EQUIPMENT
BASIC - 1 17