Alfoplus: Access Link Full Outdoor With Adaptative Code Modulation Full Ip Radio - Point To Point Radio Link
Alfoplus: Access Link Full Outdoor With Adaptative Code Modulation Full Ip Radio - Point To Point Radio Link
Alfoplus: Access Link Full Outdoor With Adaptative Code Modulation Full Ip Radio - Point To Point Radio Link
1
Training items
1. General overview ALFOplus
2. ODU Installation
3. Software connection
4. Line up
5. Ethernet switch
6. Maintenance
7. Alarms & Troubleshooting
2
ALFOPlus Connectors
LAN 2 LAN 1 Auxiliary
cable for
(Supervision port) (Traffic port) pointing cable
Status LED
it will provide additional
power supply source and
console
AUX
F03608
VRssi
(Volt)
LC connector 48 Vdc
(SFP plug-in) Power
Supply
ALFOPLUS description
Frequency range 7 to 42 GHz
Modulation 4 to 1024 QAM
Bandwidth 7,14,28,40,56 standard EU or
10,20,30,40,50 standard USA
Net Throughput 436Mbit/s (without
compression)
Radio Link 1+0 (link unprotected)
Tx dynamic Attenuator 20 dBm
Size (mm) W/H/D 254/254/154
6
ODU polarisation
Use lubricant grease Dow Corning 4 around O-Ring in order to avoid that the rubber is dried and water, sand, dust could
enter into the waveguide.
7
ODU pole mounting
Tighten the 4 screws in order crossed, first on one diagonal and after on the other. Use oil ant-seizing MOLIKOTE P-40
between the threads of nuts and bolts because often lack of lubrication could cause metal parts seized together.
1- In the top of Antenna, remove the tape and plug the cap.
2- In the bottom of Antenna, remove the cap to drain out 8
the water or Humidity.
Outdoor RJ45 Amphenol Kit
1 – Be careful when
you crimp amphenol 2 - It’is mandatory to verify with
ethernet test (not supplies) the proper
kit P20032 connectivity of both ends in order to
avoid autonegotiation problems (as for
example 1Gbps full duplex not reached).
9
Local Connection to equipment
• Using LAN2, MNGT port (1Gbps) (!! You need to know the ip
address of the radio!!)
• Using auxiliary port (115200bps 8-N-1-N) with HyperTerminal (!!
You don’t need to know the ip address of the radio!!)
• Using Rescue login (!!when you have forgotten the ip address!!)
11
Web Lct Console
12
HyperTerminal Connection
Press Enter
In capitol letter type
login: SYSTEM
Password: SIAEMICR
13
Rescue Connection with SCT
1 Assign a static IP address to your PC (172.20.253.14/16)
ALFOPLUS RESCUE IP ADDRESS is:
172.20.253.13/16
2 Connect your PC directly to ALFOplus (only Lan2)
3 With SCT, connect using Local Area
Network, press connect button, type in
equipment IP address 172.20.253.13, user:
System, Password: siaemicr and press Rescue
button
Alarms
16
Line up
1. Radio Configuration : Bandwidth & Modulation/Link ID;
Frequency Tx/Rx, Duplex Spacing; Ptx.
2. Port configuration
3. Agent IP
4. Store Routing Table
5. Remote element List or Subnetwork configuration wizard
6. Restart equipment
17
Radio Throughput
Table of capacity net Ethernet [Mbps] in different bandwidths and modulations
18
Adaptive Code Modulation setting
ACM enable: fixed bandwidth
and variable modulation, at
the maximum possible
Range of dynamic ACM disable: fixed bandwidth
Modulation
and modulation
Radio capacity:
Is Only Ethernet
Radio
Throughput
@28Mhz
19
Tx Power mode ALFOPlus 13GHz
dBm
+26
+25
+24
+23
PEAK
+22
+21
AVERAGE
4QAM-S 4QAM 16QAM-S 16QAM 32QAM 64QAM 128QAM 256QAM 512QAM 1024QAM
20
Tx Power Ramp referred at a modulation
TX power
NO NO
Modulation
4QAM 8PSK 16QAM 32QAM 64QAM 128QAM 256QAM
21
Radio Branch: Tx Frequency
2
Traffic ok (normal setting) no modulator (no traffic)
Temporary Tx off with Timeout traffic ok
Permanent Tx off without Timeout
1
5
Value of Timeout
Local Remote 17700 MHz 18200 MHz 18700 MHz 19200 MHz 19700 MHz
23
Port Configuration OH Payload
2
.73 3
RFCOH Ip Eth
1 (In-Band)
24
ALFOPLUS v01.00.01
Main >Port Configuration> Supervisioning
25
Combination1:
LAN1= Disable,
LAN2= Local Access Only
26
Combination2:
LAN1= Disable,
LAN2= Out Of Band
(Default)
27
Combination3:
LAN1= In Band ,
LAN2= Local Access Only
28
Combination4:
LAN1= In Band ,
LAN2= Drop Node
29
Combination5:
LAN1= In Band ,
LAN2= In Band
30
Combination6:
LAN1= In Band ,
LAN2= Disable
31
Web LCT: Main Menu – Equipment Properties Agent IP
Restart without cut the traffic
33
Remote element List
In order to have the whole link in one page only, local equipment is
declared “managed by SCT”, remote one is declared “remote link”.
Opposite configuration on remote side.
1 3
Create Station and Insert the
Network Element using the IP
AGENT
41 73
41 74
172.18.41.73 172.18.41.74
2
41. 74
4
34
General Preset
Rx Power Low: pre-alarm threshold configurable
by operator (independence of errors)
35
Synchronisation Priority or Quality
SETS is a hardware circuit that select the source
Web LCT: Main Menu – Synchronisation
interface of synch in base at priority or it can
switch the source according with quality.
3
2
Manual
Enable SynchE Operation
After this period the alarm appears
1
Wait time to restore After this period the alarm disappears
Free Running = missing source synch, an auto Internal synch is generated by itself (PLL).
Holdover = degrade of Synch, trying to recover. 36
Locked = normal situation of STM1 synchronisation of status control ALFOPLUS NEW 1.1.x
Synchronisation Source
1
Manual 4 Enable Source Manual reset
Operation Wait to Restore
Forced by
Operator
Status Alarms is generated by:
- LTI (Loss of timing input)
- Drift (Bad quality)
2 3
Disable
High
Low
37
Ethernet Switch Functionalities
• L2 switching: based on MAC Address and/or VLAN
• Flow Control / Back Pressure (IEEE 802.3x)
• Autonegotiation (IEEE 802.3ab)
• Jumbo Frames
• MSTP, RSTP (IEEE 802.1w, IEEE 802.1d)
• RMON Statistic
38
Ethernet switch
Routing based
on VLAN ID
MTU in Byte
39
Disabled 802.1q or Fallback Traffic Treatment
E-Line
E-LAN
S_Vid=111 Frame X
41
LAN settings: LAN PER PORT
Radio Port
Table of MAC
address enable
= 1Gb
44
Spanning Tree Protocol
Interface Lan1 belong at group Bridge1 of Spanning Tree Protocol or IEEE802.1D or
IEEE802.1W.
Low Priority
High Priority
Low Priority
High Priority
This interface displays and settings the port states on the feature
enabled. You can enable a single function at time per port
45
ALFOPLUS v01.03.00
Spanning Tree
Resend BPDU
Change Status port
Life of BPDU
46
Parameter used to elect the root bridge
ALFOPLUS v01.03.00
LOOPS
0 sec = disable
Manual operation
Timeout
Line Loop
To detail
49
Performance monitoring
Alarm Status
Threshold
50
Report & Logger Maintenance
Details of Configuration
stored in the radio
51
Software info & Maintenance
IP Factory Default
172.20.254.14/16 ODU L
172.20.255.15/16 ODU H
52
!!! SCT or WLC is necessary for FTP file transfer !!!
Backup/Restore Configuration
Backup with SCT – Tools - Equipment Configuration Wizard
Full Backup ( Radio Config. , Address, Remote List ) : file not
editable
Partial Backup Configuration : file editable
- Config. (modulation,capacity,frequency channel, etc)
- Address (IP Eth, Radio PPP, Routing table, etc)
- Remote List
Backup with WebLCT
Full Backup : file not editable
54
Alarm Severity Configuration
3 double click
2
55
User Manager SNMP Monitor Server
57
ALFOPLUS NEW 1.1.x
Front panel LED:
• Orange = Reboot status Alarms Notification
• Red On = An Internal alarm is active
• Red Flashing = An external Alarm is active
• Green On = Radio connection with far end terminal is active
• Green Flashing = No radio connection with far-end terminal
Alarm windows
• SCT: All alarms are listed in “Event History” or the active alarms can be
monitored in a “View current alarms” windows.
• WEBLCT: all current alarms are present in “Event list” area.
Group Alarm:
URGent Critical (red) Hw Fail
affect traffic Link Down Major (Orange) Los
TEST = Active Manual Operation (Loop, Radio Switch, FM test, Radio BER TEST, etc)
58
Who can generate alarms in a radio link system?
1 ) Propagations of MicroWave
- Interference (in a Link radio turn off the Ptx module (local & remote) and
monitoring the Prx during the day, active Local Link ID)
- Desalign of Antenna (check positions and screws, maximize the Voltage AUX
connector present in ODU)
- Obstacle in the 1° Fresnel Zone (tree, tower building, etc …)
- Particular condition (heavy rain, stratification of different air temperature, flat
surface)
- Using the “Performance Monitoring” Prx, Ptx, BER measuring
2 ) Radio Hardware faulty
- Alarms due of a wrong configurations or actual status of the Radio
- Faulty (using Radio BER TEST to check a Hardware failure)
3 ) External Event
- No constant 48 Volt Power supply during the day/night
- Very High temperature, humidity inside waveguide.
- ODU operating range -33° to +55°C; survival temperature range -40°C to +70°C
- ODU Waterproof according to IP65 environmental class
59
Troubleshooting
Troubleshooting is performed with :
- Check value Power of Transmitter and Receiver.
- Reading Current Alarms and Alarm History labels and
trying to figure out which part of the equipment is affected,
in the following pages there is a description of alarms.
- Disable All Manual Operations.
- Verifying with RADIO BER TEST a Hardware failure or S/N
Measure.
- Verifying the correct initialization of the Local and Remote
Radio.
- HW Restart.
- Factory default
- Firmware Update
- Replace with a spare part. 60
Alarms grouping : Current Alarms
Alarms are divided into groups, the group name
represents the origin of the module that has caused
him.
with SCT
SCT: Equipment – View
Current Alarms…
WEBLCT
61
Alarms groups : COMMON
Alarms related to Controller module and EOC channel.
62
Equipment manual operation
2 – type Timeout =1 sec to clear all Manual Op.
64
Alarms groups: P.M. (Performance Monitoring)
Alarms regarding all measurements in Performance Monitoring
section.
65
Alarms groups: Plug-in module
Alarms relevant the plug-in modules used for optical lines.
66
Alarms groups: RADIO
Specific alarms the ODU and Radio link.
67
Alarms groups: RADIO
68
Link telemetry fail
No link between Local and Remote station. Traffic & Mngt is cut.
Demodulator fail can be when:
To solve problem, try :
-the remote radio is power OFF or TX power Off
-Disable manual operations
-Frequency Channel Local ≠ Remote
-Check Power Tx/Rx and Frequency chan.
-RF Loop on remote Radio
-Line-up (Local&Remote)
-IDU/ODU damaged (using BER TEST to verify the faulty)
69
Adaptive Modulation Reduce Capacity Notification
When ACM Engine is enable in both radio (Local and Remote)
and the actual Tx/Rx modulation < Upper modulation.
70
RT Rx Power Low
This alarm occurs when Rx power is under a defined threshold
Threshold value can be set in range:
-40dBm -99dBm in General preset
The alarm Rx Power Low is a branch alarm and it is used to drive Rx switch
71
RT Tx Power Low
This alarm occurs when actual Tx power is 3 dB under the Tx Power
control setted manually.
74
ACRONYMS
75
More info? …consult the manual
ALFOPLUS - User manual (mn.00273.e).pdf
WEB LCT ALFOPLUS - User manual (mn.00281.e).pdf
Contact Siae
commercial reference
76