Sharp Writeview EL-W535 Manual
Sharp Writeview EL-W535 Manual
Sharp Writeview EL-W535 Manual
ENGLISH
Symbol
SCIENTIFIC CALCULATOR
MODEL
Mantissa
Exponent
Memory clear key Press @ P to display the menu. To initialize the display settings, press 0. The parameters set as follows: Angular unit: DEG Display notation: NORM1 N-base: DEC To clear all variables and memories (AF, M, X, Y, D1D4, ANS, and STAT) at once, press 1 0. To RESET the calculator, press 2 0. The RESET operation will erase all data stored in memory and restore the calculators default settings.
Equations that have one result require an additional eleven characters worth of memory to store in order to hold the result. In addition to the amount of memory needed to store an equation, the WriteView editor will require a certain amount for the sake of display. Equations also include calculation ending instructions, such as =.
Functions
Refer to the calculation examples for each function. In the Line editor, the following symbols are used: : to indicate an expressions power. (m, @ ", @ Y) : to separate integers, numerators, and denominators. (W, @ k) When using @ O or @ W in the Line editor, values are entered in the following way: logn (base, value) abs value
OPERATION MANUAL
PRINTED IN CHINA / IMPRIM EN CHINE / IMPRESO EN CHINA 07BGK (TINSE1278EHZZ)
INTRODUCTION
Thank you for purchasing the SHARP Scientic Calculator Model EL-W531/W531G/W531H/W531HA/W535. About the calculation examples (including some formulas and tables), refer to the reverse side of this English manual. Refer to the number on the right of each title in the manual for use. After reading this manual, store it in a convenient location for future reference. Notes: Some of the models described in this manual may not be available in some countries. This product uses a period as a decimal point.
During actual use, not all symbols are displayed at the same time. Only the symbols required for the usage under instruction are shown in the display and calculation examples of this manual. Indicates that some contents are hidden in the / : / directions shown. 2ndF: Appears when @ is pressed, indicating that the functions shown in orange are enabled. HYP: Indicates that H has been pressed and the hyperbolic functions are enabled. If @ > is pressed, the symbols 2ndF HYP appear, indicating that inverse hyperbolic functions are enabled. ALPHA: Indicates that ;, x or t has been pressed, and entry (recall) of memory contents and recall of statistics can be performed. DEG/RAD/GRAD: Indicates angular units. BUSY: Appears during the execution of a calculation. W-VIEW: Indicates that the WriteView editor is selected. M: Indicates that a numerical value is stored in the independent memory (M). ENG/SCI/FIX/N2/N1: Indicates the notation used to display a value and changes by SET UP menu. N1 is displayed on-screen as NORM1, and N2 as NORM2.
Random Function
The random function has four settings. (This function cannot be selected while using the N-base function.) To generate further random numbers in succession, press e. Press j to exit. Random numbers A pseudo-random number, with three signicant digits from 0 up to 0.999, can be generated by pressing @ w 0 e. Note: In the WriteView editor, the result will be a fraction or 0. Random dice To simulate a die-rolling, a random integer between 1 and 6 can be generated by pressing @ w 1 e. Random coin To simulate a coin ip, 0 (heads) or 1 (tails) can be randomly generated by pressing @ w 2 e. Random integer An integer between 0 and 99 can be generated randomly by pressing @ w 3 e.
Entry and display In the WriteView editor, you can enter and display fractions or certain functions as you would write them. Notes: The WriteView editor can only be used in NORMAL mode. If the equation grows too large, it may extend off the edge of the display after you obtain the result. If you want to see the entire equation, press l or r to return to the editing screen. Displaying calculation results When possible, calculation results will be displayed using fractions, r, and . When you press U, the display will cycle through the following display styles: improper fractions (with Mixed fractions (with or without ) decimal numbers or without ) decimal numbers Proper fractions (with or without ) Irrational numbers (square roots, fractions made using square roots) decimal numbers Notes: In the following cases, calculation results may be displayed using r: Arithmetic operations and memory calculations Trigonometric calculations In trigonometric calculations, when Entry value entering values such as those in multiples of 15 the table to the right, results may be DEG 1 shown using r. RAD multiples of 12 Calculation results may extend off 50 GRAD multiples of 3 the edges of the screen. You can see those parts by pressing l or r (depending on whether the left or right portion is hidden). Improper/proper fractions will be converted to and displayed as decimal numbers if the number of digits used in their expression is greater than nine. In the case of mixed fractions, the maximum number of displayable digits (including integers) is eight. If the number of digits in the denominator of a fractional result that uses is greater than three, the result is converted to and displayed as a decimal number.
SET UP Menu
Press J to display the SET UP menu. Press j to exit the SET UP menu. Determination of the angular unit The following three angular units (degrees, radians, and grads) can be specied. DEG (): J 0 0 (default) RAD (rad): J 0 1 GRAD (g): J 0 2
3 Selecting the display notation and decimal places Five display notation systems are used to display calculation results: Two settings of Floating point (NORM1 and NORM2), Fixed decimal point (FIX), Scientic notation (SCI), and Engineering notation (ENG). When J 1 0 (FIX) or J 1 2 (ENG) is pressed, TAB(09)? will be displayed and the number of decimal places (TAB) can be set to any value between 0 and 9. When J 1 1 (SCI) is pressed, SIG(09)? will be displayed and the number of signicant digits can be set to any value between 0 and 9. Entering 0 will set a 10-digit display.
Operational Notes
Do not carry the calculator around in your back pocket, as it may break when you sit down. The display is made of glass and is particularly fragile. Keep the calculator away from extreme heat such as on a car dashboard or near a heater, and avoid exposing it to excessively humid or dusty environments. Since this product is not waterproof, do not use it or store it where uids, for example water, can splash onto it. Raindrops, water spray, juice, coffee, steam, perspiration, etc. will also cause malfunction. Clean with a soft, dry cloth. Do not use solvents or a wet cloth. Do not drop it or apply excessive force. Never dispose of batteries in a re. Keep batteries out of the reach of children. This product, including accessories, may change due to upgrading without prior notice.
Memory Calculations
Memory calculations can be performed in NORMAL and STAT modes. Temporary memories (AF, X and Y) Press x and a variable key to store a value in memory. Press t and a variable key to recall the value from that memory. To place a variable in an equation, press ; and a variable key. Independent memory (M) In addition to all the features of temporary memories, a value can be added to or subtracted from an existing memory value. Press j x M to clear the independent memory (M). Last answer memory (ANS) The calculation result obtained by pressing = or any other calculation ending instruction is automatically stored in the last answer memory. Notes: Calculation results from the functions indicated below are automatically stored in the X or Y memories replacing any existing values. r , xy: X memory (r or x), Y memory ( or y) Two x values from a quadratic regression calculation in STAT mode: X memory (1:), Y memory (2:) Use of t or ; will recall the value stored in memory using up to 14 digits. Denable memories (D1D4) You can store functions or operations in denable memories (D1D4). To store a function or operation, press x, followed by a denable memory key (I, J, K, or L), followed by the operation you want to store. Menu-related operations, such as J, cannot be stored. Press j to return to the previous display. To call a stored function or operation, press the corresponding memory key. Calling a stored function will do nothing if the function that is called would be unusable in the current context. Any functions or operations that are stored in a denable memory will be replaced when you save a new one into that memory. When displaying and correcting a data set in STAT mode, you cannot store functions or operations in denable memories.
NOTICE
SHARP strongly recommends that separate permanent written records be kept of all important data. Data may be lost or altered in virtually any electronic memory product under certain circumstances. Therefore, SHARP assumes no responsibility for data lost or otherwise rendered unusable whether as a result of improper use, repairs, defects, battery replacement, use after the specied battery life has expired, or any other cause. SHARP will not be liable nor responsible for any incidental or consequential economic or property damage caused by misuse and/or malfunctions of this product and its peripherals, unless such liability is acknowledged by law. Press the RESET switch (on the back), with the tip of a ball-point pen or similar object, only in the following cases. Do not use an object with a breakable or sharp tip. Note that pressing the RESET switch erases all data stored in memory. When using for the rst time After replacing the battery To clear all memory contents When an abnormal condition occurs and all keys are inoperative If service should be required on this calculator, use only a SHARP servicing dealer, SHARP approved service facility, or SHARP repair service where available.
Setting the oating point number system in scientic notation Two settings are used to display a oating-point number: NORM1 (the default) and NORM2. A number is automatically displayed in scientic notation outside a preset range: NORM1 (J 1 3): 0.000000001 | x | 9,999,999,999 NORM2 (J 1 4): 0.01 | x | 9,999,999,999 Selecting the editor Two editors are available in NORMAL mode: The WriteView editor (W-VIEW): J 2 0 (default) The Line editor (LINE): J 2 1 Adjusting the display contrast Press J 3, then + or & to adjust the contrast. Press j to exit. Insert and overwrite entry methods When using the Line editor, you can change the entry method from INSERT (the default) to OVERWRITE. After you switch to the overwrite method (by pressing J 4 1), the triangular cursor will change to a rectangular one, and the number or function underneath it will be overwritten as you make entries.
Note: In certain calculation examples, where you see the o symbol, the key operations and calculation results are shown as they would appear in the Line editor.
Just after obtaining an answer, pressing l brings you to the end of the equation and pressing r brings you to the beginning. Press l, r, u, or d to move the cursor. Press @ l or @ r to jump the cursor to the beginning or the end of the equation. In the WriteView editor, you can use u and d to move the cursor up and downbetween the numerator and denominator, for example. Back space and delete key To delete a number or function, move the cursor to the right of it, then press N. You can also delete a number or function that the cursor is directly over by pressing @ y.
SCIENTIFIC CALCULATIONS
Press b 0 to select NORMAL mode. In each example, press j to clear the display rst. Unless otherwise specied, calculation examples are performed in the WriteView editor with the default display settings (@ P 0).
Hard Case
Chain Calculations
Arithmetic Operations
Remove the hard case, holding it with your ngers in the positions shown below.
This calculator is equipped with a function to recall previous equations and answers in NORMAL mode. A maximum of 340 characters can be stored in memory. When the memory is full, stored equations will be deleted to make room, starting with the oldest. Pressing u will display the previous equation. Further pressing u will display preceding equations (after returning to the previous equation, press d to view equations in order). In addition, @ u can be used to jump to the oldest equation, and @ d to jump to the newest one. To edit an equation after recalling it, press l or r. The multi-line memory will be cleared by the following operations: @ Z , mode change, RESET, N-base conversion, angular unit conversion, editor change (J 2 0 or J 2 1), and memory clear (@ P 1 0).
The previous calculation result can be used in the subsequent calculation. However, it cannot be recalled after entering multiple instructions.
Constant Calculations
Fraction Calculations
10
In constant calculations, the addend becomes a constant. Subtraction and division are performed in the same manner. For multiplication, the multiplicand becomes a constant. In constant calculations, constants will be displayed as K.
Arithmetic operations and memory calculations can be performed using fractions. In NORMAL mode, conversion between a decimal number and a fraction can be performed by pressing U. Notes: Improper/proper fractions will be converted to and displayed as decimal numbers if the number of digits used in their expression is greater than nine. In the case of mixed fractions, the maximum number of displayable digits (including integers) is eight. To convert a sexagesimal value to a fraction, rst convert it by pressing @ :.
Mean of samples (x data) Sample standard deviation (x data) Population standard deviation (x data) Number of samples Sum of samples (x data)
2
DRILL MODE
Math Drill: b 2 0 Math operation questions with positive integers and 0 are displayed randomly. It is possible to select the number of questions and operator type. Multiplication Table ( Table): b 2 1 Questions from each row of the multiplication table (1 to 12) are displayed serially or randomly. To exit DRILL mode, press b and select another mode.
Error codes and error types ERROR 01: Syntax error An attempt was made to perform an invalid operation. Ex. 2 + & 5 = ERROR 02: Calculation error The absolute value of an intermediate or nal calculation result equals or exceeds 10100. An attempt was made to divide by zero (or an intermediate calculation resulted in zero). The calculation ranges were exceeded while performing calculations. ERROR 03: Nesting error The available number of buffers was exceeded. (There are 10 buffers for numeric values and 64 buffers for calculation instructions). ERROR 04: Data over Data items exceeded 100 in STAT mode.
sx
n
x x
y
If the product is not to be used for some time, to avoid damage to the unit from a leaking battery, remove it and store in a safe place. Do not leave an exhausted battery inside the product. Keep batteries out of the reach of children. An exhausted battery left in the calculator may leak and damage the calculator. Explosion risk may be caused by incorrect handling. Do not throw batteries into a re as they may explode.
Sum of squares of samples (x data) Mean of samples ( y data) Sample standard deviation ( y data) Population standard deviation ( y data) Sum of samples ( y data)
Replacement Procedure
1. Turn the power off by pressing @ o. 2. Remove the two screws. (Fig. 1) 3. Slide the battery cover slightly and lift it to remove. 4. EL-W531/W531G/W535: Remove the used battery by prying it out with a ball-point pen or other similar pointed device. (Fig. 2) EL-W531H/W531HA: Remove the used battery. 5. EL-W531/W531G/W535: Install one new battery. Make sure the + side is facing up. EL-W531H/W531HA: Install one new battery. First insert the side toward the spring. (Fig. 3) 6. Replace the cover and screws. 7. Press the RESET switch (on the back) with the tip of a ball-point pen or similar object. 8. Adjust the display contrast. See Adjusting the Display Contrast. Make sure that the display appears as shown below. If the display does not appear as shown, remove the battery, reinstall it, and check the display once again.
sy
y y
Sum of squares of samples ( y data) Sum of products of samples (x, y) Correlation coefcient Coefcient of regression equation Coefcient of regression equation Coefcient of quadratic regression equation
xy
r a
b
Alert Messages
Cannot delete! The selected item cannot be deleted by pressing N or @ y in the WriteView editor. Ex. * 5 r A l N In this example, delete the exponent before attempting to delete the parentheses.
18
12
Conversion between decimal and sexagesimal numbers can be performed. In addition, the four basic arithmetic operations and memory calculations can be performed using the sexagesimal system. Notation for sexagesimal is as follows:
Use ; and t to perform a variable calculation in STAT mode. U does not function in STAT mode.
Degree
Minute
Second
13
16
Cannot call! The function or operation stored in denable memory (D1 to D4) cannot be called. Ex. An attempt was made to recall a statistical variable from within NORMAL mode. Buffer full! The equation (including any calculation ending instructions) exceeded its maximum input buffer (159 characters in the WriteView editor or 161 characters in the Line editor). An equation may not exceed its maximum input buffer.
Coordinate Conversions
Before performing a calculation, select the angular unit. The calculation result is automatically stored in the X and Y memories (r or x in X memory, and or y in Y memory). The results of coordinate conversions will be displayed as decimal numbers even in the WriteView editor.
Rectangular coord.
Polar coord.
14
Modify Function
Decimal calculation results are internally obtained in scientic notation, with up to 14 digits in the mantissa. However, since calculation results are displayed in the form designated by the display notation and the number of decimal places indicated, the internal calculation result may differ from that shown in the display. By using the modify function (@ n), the internal value is converted to match that of the display, so that the displayed value can be used without change in subsequent operations. When using the WriteView editor, if the calculation result is displayed using fractions or irrational numbers, press U to convert it to decimal form rst.
Data entry Single-variable data Data _ Data H frequency _ (To enter multiples of the same data) Two-variable data Data x H data y _ Data x H data y H frequency _ (To enter multiples of the same data x and y) Note: Up to 100 data items can be entered. With the singlevariable data, a data item without frequency assignment is counted as one data item, while an item assigned with frequency is stored as a set of two data items. With the two-variable data, a set of data items without frequency assignment is counted as two data items, while a set of items assigned with frequency is stored as a set of three data items. Data correction Correction before pressing _ immediately after a data entry: Delete incorrect data with j, then enter the correct data. Correction after pressing _: Use u and d to display the previously entered data set. Press d to display the data set in ascending (oldest rst) order. To reverse the display order to descending (latest rst), press the u key. Press @ u or @ d to jump the cursor to the beginning or end of the data set. Each data set is displayed with X:, Y:, or F:.
Data set number Data x Frequency
Fig. 1
Fig. 2
Fig. 3
Calculation Ranges
19
Within the ranges specied, this calculator is accurate to 1 of the 10th digit of the mantissa. However, a calculation error increases in continuous calculations due to accumulation of each calculation error. (This is the same for y x, xr, n!, e x, ln, etc., where continuous calculations are performed internally.) Additionally, a calculation error will accumulate and become larger in the vicinity of inection points and singular points of functions. Calculation ranges 1099 to 9.999999999 1099 and 0. If the absolute value of an entry or a nal or intermediate result of a calculation is less than 1099, the value is considered to be 0 in calculations and in the display. Display of results using r Calculation results may be displayed using r when all of the following conditions are met: When intermediate and nal calculation results are displayed in the following form: P P a eb c d f When each coefcient falls into the following ranges: 1 a < 100; 1 < b < 1,000; 0 c < 100; 1 d < 1,000; 1 e < 100; 1 f < 100 When the number of terms in the intermediate and nal calculation results is one or two. Note: The result of two fractional terms that include r will be reduced to a common denominator.
SPECIFICATIONS
Calculation features: Scientic calculations, statistical calculations, etc. Drill features: Math Drill and Multiplication Table Display: 96 32 dot matrix liquid crystal display Display of calculation results: Mantissa: 10 digits Exponent: 2 digits Internal calculations: Mantissas of up to 14 digits Pending operations: 64 calculations 10 numeric values Power source: EL-W531/W535 1.5 V (DC): Alkaline battery (LR44 or equivalent) 1 EL-W531G Built-in solar cells 1.5 V (DC): Backup battery (Alkaline battery (LR44 or equivalent) 1) EL-W531H/W531HA 1.5 V (DC): Heavy duty manganese battery (size AAA or R03) 1 Power consumption: EL-W531/W531H/W531HA/W535 0.00011 W Operating time: EL-W531/W535 (varies according to Approx. 3,000 hours when continuously use and other factors) displaying 55555. at 25C (77F) EL-W531G Approx. 3,000 hours when continuously displaying 55555. at 25C (77F), using the alkaline battery only EL-W531H/W531HA Approx. 17,000 hours when continuously displaying 55555. at 25C (77F) Operating temperature: 0C40C (32F104F) External dimensions: 79.6 mm (W) 161.5 mm (D) 15.5 mm (H) 3-1/8 (W) 6-11/32 (D) 5/8 (H) Weight: EL-W531/W535 Approx. 100 g (0.22 lb) (including battery) EL-W531G Approx. 102 g (0.23 lb) (including battery) EL-W531H/W531HA Approx. 107 g (0.24 lb) (including battery) Accessories: Battery 1 (installed), operation manual, and hard case
STATISTICAL CALCULATIONS
Statistical calculations can be performed in STAT mode. There are eight sub-modes within STAT mode. Press b 1, then press the number key that corresponds to your choice: 0 (S#a# 0 [SD]): Single-variable statistics 1 (S#a# 1 [LINE]): Linear regression 2 (S#a# 2 [QUAD]): Quadratic regression 3 (S#a# 3 [E_EXP]): Euler exponential regression 4 (S#a# 4 [LOG]): Logarithmic regression 5 (S#a# 5 [POWER]): Power regression 6 (S#a# 6 [INV]): Inverse regression 7 (S#a# 7 [G_EXP]): General exponential regression
Table sample
Total remaining questions Question Data set number Data x Data y Frequency
15
Display and move the cursor to the data item to be modied by using u and d, input the correct value, then press _ or e. To delete a data set, display and move the cursor to an item of the data set to delete by using u and d, then press @ #. The data set will be deleted. To add a new data set, press j to exit the display of previously entered data and input the values, then press _.
17
y = a + bx y = a + bx + cx 2 y = a ebx y = a + b ln x y = a xb
1 y=a+b x
Quadratic regression calculation Statistics of and , and coefcients a, b, c in the quadratic regression formula ( y = a + bx + cx 2). (For quadratic regression calculations, no correlation coefcient (r) can be obtained.) When there are two x values, each value will be displayed with 1: or 2:, and stored separately in the X and Y memories. Euler exponential regression, logarithmic regression, power regression, inverse regression, and general exponential regression calculations Statistics of and . In addition, the estimate of y for a given x and the estimate of x for a given y. (Since the calculator converts each formula into a linear regression formula before actual calculation takes place, it obtains all statistics, except coefcients a and b, from converted data rather than entered data.)
y = a bx
An error will occur when: The absolute value of the intermediate result or calculation result is equal to or greater than 1 10100. The denominator is zero. An attempt is made to take the square root of a negative number. No solution exists in the quadratic regression calculation.
Cautions
Fluid from a leaking battery accidentally entering an eye could result in serious injury. Should this occur, wash with clean water and immediately consult a doctor. Should uid from a leaking battery come in contact with your skin or clothes, immediately wash with clean water.
ENGLISH
(123) = 4 o 83 = p 4p = 49 81 o 140. 3
-90 3p
( 12 m 3 r)m 1W4=
0M 6.447419591 $150 3 M1
jxM 150 k 3 m
0. 450. 250.
2 1.25 + = 1.25 + 2 W 5 = 5 U U
13 20 33 20
( 12 m 3 ) m 1 W 4 = 6.447419591 8@1= * 49 r & 4 @ D 81 = * 49 & 4 @ D 81 = @ q 27 = 4@B= 512. 4. 4. 3. 24. 720. 10. 125. 30. 625. 280. 4. 4.
[NORM1] 4
1.25 + 2 W 5 = U U
+&kz()S`
j 45 + 285 z 3 = ( 18 + 6 ) z (15 & 8 = 42 k S 5 + 120 =
45 + 285 3 = 18 + 6 = 15 8 42 5 + 120 =
3 7
27 =
4! =
10P3 5C2
302'500. 3.
5 * 4m5m6 = 4 6 11
1'250'000.
r 2 = ?
2 2 4 + 6 = 5 (A) 3 (A) + 60 (A) = sinh1 D1 sinh1 0.5 = 9 6 + 4 = ANS ANS + 5 = 8 2 = ANS ANS2 = 44 + 37 = ANS ANS = 10 24
28.27433388 2 32
1 5 2 5
zrgh/dn4 pxC
BIN j@/ 25 @ z @ h 1AC @z @r @g @/ @z( 1010 & 100) k 11 = BIN PEN OCT 110101100 3203 654 428. BIN 11001
|5 9| =
o
@W5&9= @W(5&9 )=
I 0.5 =
0.481211825
OCT DEC
CONTOH-CONTOH PERHITUNGAN
1 2 5
U
3 4 j2W5r +W3r4 = U U U 1
3 20
+=
BIN
10010
BIN (111) NEG d 111 = HEX (1FF) + OCT (512) = HEX (?) @ h 1FF @g+ 512 = @h
BIN 1111111001
23 20
sin 60 [] =
j v 60 = U
2
0.866025403
2 2
Q
Q 3
1.15
3 1 20
OCT HEX
1511 349
P P= 3 5
cos [rad] = 4
*3rk*5 = U
J01 $sW4= U
H 15 tan11 [g] =
0.707106781 50.
Wk
j3@k1d2r +W4d3= U 4
29 6 5 6
3.872983346
3Q Q 5+5 2 15
1 4 3 + = 2 3
2FEC 2C9E M1
jxM @ h 2FEC & 2C9E m HEX 2000 &1901 m HEX tM jxM HEX
0.918618116
2 2
Q
(cosh 1.5 + sinh 1.5)2 = j ( H $ 1.5 + H v 1.5 ) A = 20.08553692 5 tanh1 = 7 ln 20 = log 50 = log2 16384 = o @>t( 5 z 7 ) = 0.895879734 i 20 = l 50 = 2.995732274 1.698970004 14. 14. 7
= sin1 x, = tan1 x
DEG RAD GRAD
= cos1 x
U 0 180 0 0 200 o
+) 2000 1901 M2 M=
90 90 2 2 100 100
4.833333333
3W1W2+4W3= U U
* 4m5m6
29m6
1011 AND 101 = @ z 1011 4 101 = [BIN] BIN 5A OR C3 = [HEX] NOT 10110 = [BIN] 24 XOR 4 = [OCT] B3 XNOR 2D = [HEX] DEC 12 @ h 5A p C3 = @zn 10110 = @ g 24 x4= @ h B3 C 2D = @/ HEX
1 DB
0.707106781
2 J 3
2.094395102
4.833333333 4.641588834
16807 3125
ud
@Z 0. 21. 17. 16. 21. 17. 16. 17.
]
j 90 @ ] @] @] = [] @ w 0.8 = @] @] @]
1 J 2
10 3 = 7 () 5
5
HEX FFFFFFFF61
-159.
3(5 + 2) = 35+2=
3(5+2)= 3k5+2=
e3 = 1e= 101.7 =
20.08553692 0.367879441
o
3
16807m3125
1 2 8 15 8 81
= 8
64 = 225
[:
[10] j 7 [ 31 [ 49.44 @ : [60] 123.678 @ : 3 [ 30 [ 45 + 6 [ 45 [ 36 = 7
663 1250
(5 + 3) 2 = ( 5 + 3) k 2 = 3 @u d d u
73149.44 123.678
+=
1 6
1 7
0.309523809
2 = 34 o
123(40q40.8"
3h 30m 45s + 6h 45m 36s = [60] 12345612 + 0034.567 = [60] 3h 45m 1.69h = [60]
82 34 52 =
-2024 -
63 64
;txmM<IJK L
j8k2xM 24 z ; M = ;Mk5= 16.
1 1 2
8m81
12 23
10(16 q21."
129599 64
82M 24 (8 2) = (8 2) 5 =
0(31 q1.5"
1 2
-2'024.984375
8mS2& 3m4k5 A= U U
80.
0.884635235
7A 4 = A
7.
4 7
uEH
j6H4 @u 14 H 36 @E r: {: X: Y: 7.211102551 33.69006753 11.32623792 8.228993532
( ( r == [] ( r == 14 [] ( xy = = 36
x=6 y=4
14
nJ
DATA [FIX, TAB = 1] j J 1 0 1 0.0
5 9
S#a# 2 [QUAD] 0. DATA SET= DATA SET= DATA SET= DATA SET= DATA SET= 1. 2. 3. 4. 5.
18 Function keys Display Buffer space* Funktionstasten Anzeige Pufferplatz* Touches de fonction Afchage Espace tampon* Visualizador Espacio de memoria intermedia* Teclas de funcin Exibio Espao na memria intermediria* Teclas de funo Memoria tampone* Display Tasti di funzione Bufferruimte* Display Functietoetsen Pufferterlet* Kijelz Fggvnybillentyk Vyrovnvac pam* Zobrazen Tlatka funkc Buffertutrymme* Visning Funktionstangenter Puskuritila* Nytt Funktionppimet Bufferplads* Display Funktionstaster * Tombol fungsi @Z A @1 m @O @" Tampilan Ruang buffer* 1 1 1 5 7 5 5 5 5 7 7 5 4
19 Function Funktion Fonction Funcin Funo Funzioni Functie Fggvny Funkce Funktion Funktio Funktion Dynamic range zulssiger Bereich Plage dynamique Rango dinmico Gama dinmica Campi dinamici Rekencapaciteit Megengedett szmtsi tartomny Dynamick rozsah Definitionsomrde Dynaaminen ala Dynamikomrde
x
12
y
41 13 2 200 71
NOT
5 9 = ANS
5z9= U
8 5 23 15
0.6
1
BIN: 1000000000 x 1111111111 0 x 111111111 PEN: 2222222223 x 4444444444 0 x 2222222221 OCT: 4000000000 x 7777777777 0 x 3777777777 HEX: FDABF41C01 x FFFFFFFFFF 0 x 2540BE3FE BIN: 1000000001 x 1111111111 0 x 111111111 PEN: 2222222223 x 4444444444 0 x 2222222222 OCT: 4000000001 x 7777777777 0 x 3777777777 HEX: FDABF41C01 x FFFFFFFFFF 0 x 2540BE3FF
ANS 9 =
k9=*
5.0
5 9
NEG
0.6
3 5
a=
b=
a=
b=
5.357506761
-3.120289663
Fungsi
Kisaran dinamis DEG: | x | < 1010 (tan x : | x | 90(2n 1))* RAD: | x | < 180 1010 (tan x: | x | (2n 1))* 2 GRAD: | x | < 1010 9 (tan x: | x | 100(2n 1))*
10
5 5.4 5.4
2 5
c= x = 10 y = 22
c=
10 y 22 x 1: 2:
1 2 3
log() e 10 P
3P
y = ? 10 @ U x = ? 22 @ V
* n, r: integer / ganze Zahlen / entier / entero / inteiro / intero / geheel getal / egsz szmok / cel slo / heltal / kokonaisluku / heltal / / / bilangan bulat
Nur fr Deutschland/For Germany only: Umweltschutz Das Gert wird durch eine Batterie mit Strom versorgt. Um die Batterie sicher und umweltschonend zu entsorgen, beachten Sie bitte folgende Punkte: Bringen Sie die leere Batterie zu Ihrer rtlichen Mlldeponie, zum Hndler oder zum KundenserviceZentrum zur Wiederverwertung. Werfen Sie die leere Batterie niemals ins Feuer, ins Wasser oder in den Hausmll. Seulement pour la France/For France only: Protection de lenvironnement Lappareil est aliment par pile. Afin de protger lenvironnement, nous vous recommandons: dapporter la pile usage ou votre revendeur ou au service aprs-vente, pour recyclage. de ne pas jeter la pile usage dans une source de chaleur, dans leau ou dans un vide-ordures. Endast svensk version/For Sweden only: Miljskydd Denna produkt drivs av batteri. Vid batteribyte skall fljande iakttagas: Det frbrukade batteriet skall inlmnas till batteriinsamling eller till kommunal miljstation fr terinssamling. Kasta ej batteriet i vattnet eller i hushllssoporna. Batteriet fr ej heller utsttas fr ppen eld. For Europe only:
-3.432772026
16
_Hud#
b10 DATA 20 30 40 40 50 50 _ DATA SET= 4. 20 _ 30 _ 40 H 2 _ S#a# 0 [SD] 0. DATA SET= DATA SET= DATA SET= 1. 2. 3.
@Y * @q @D W/@k @W ()
_HRvpcgoQ GsijhfabS VU
b 1 0 S#a# 0 [SD] @Z DATA 95 80 80 75 75 75 50 95 _ 80 _ _ DATA SET= DATA SET= DATA SET= 0. 1. 2. 3. 4. 5.
ln x, log x, loga x
yx
y < 0:
|| ( )
10100 < x log | y | < 100 10100 < log y < 100 (x 0) x y = 0: 0 < x < 10100 y < 0: x = 2n 1 1 (0 < | x | < 1: = n, x 0)*, x
y > 0:
x
DATA 30 45 45 45 60 17 = x x
d@#
DATA SET=
3. 45. 3.
d d d 45 _ X: 3_ F:
= x x = n= x = x2 = sx = sx2 =
(95 ) x
d 60 _
X:
60.
x =
x 2 nx 2 n1
x 2 nx 2
sx2 = 178.5714286
sx =
= y y
x = x1 + x2 + + xn x2 = x1 2 + x2 2 + + xn2 y = n xy = x1 y1 + x2 y2 + + xn yn y = y1 + y2 + + yn y 2 = y1 2 + y2 2 + + yn2
y
2
ny 2
64.43210706 S#a# 1 [LINE] 0. DATA SET= DATA SET= DATA SET= DATA SET= DATA SET= 1. 2. 3. 4. 5.
sy =
y 2 ny 2 n1
x
2 2 12 21 21 21 15
y
5 5 24 40 40 40 25
* The amount of memory used for the sake of display in the WriteView editor, measured in characters (excluding entered values, denoted in the chart by ). * Der fr die Anzeige in WriteView Editor verwendete Speicherplatz, gemessen in Zeichen (ohne die eingegebenen Werte, die in der Tabelle mit markiert sind). * Espace mmoire utilis pour prserver lafchage dans lditeur WriteView, mesur en caractre ( lexception des valeurs dentre, indiques dans le tableau par ). * La cantidad de memoria usada para visualizar en el editor Write View, medida en caracteres (excluyendo los valores introducidos, indicados en el graco mediante ). * A quantidade de memria que usada para a exibio no editor WriteView, medida em caracteres (excluindo os valores introduzidos, indicados no quadro por ). * La quantit di memoria utilizzata per la visualizzazione nelleditor WriteView, misurata in caratteri (escludendo i valori inseriti, indicati nella tabella con il simbolo ). * De hoeveelheid geheugen dat wordt gebruikt om de WriteView editor weer te geven, gemeten in symbolen (met uitzondering van ingevoerde waarden aangeduid in de graek met ). * A WriteView szerkeszt megjelentsi mveleteire hasznlatos memriaterlet, karakterben kifejezve (az brn karakterrel jellt beviteli rtkeket nem szmtva). * Mnostv pamti vyuvan pro ely zobrazen v editoru WriteView, vyjden potem znak (vyjma zadanch hodnot, oznaench v grafu znakem ). * Den mngd minne som anvnds fr visning med WriteViewredigeraren, mtt i antalet tecken (exklusive inmatade vrden, vilka anges som i tabellen). * Nytn WriteView-editorissa kyttm muisti merkkein laskettuna (pois lukien sytetyt arvot, taulukossa merkitty ). * Den mngde hukommelse, der bruges til visning i WriteVieweditoren, mlt i tegn (med undtagelse af indtastede vrdier, der angives med i tabellen).
y P
x2 x3 x P x 1
n!
nPr
< 10
100
nCr
0 r n 9999999999* 0 r 69
n! (n r)!
< 10100
DEG, DMS
x, y
r,
x 2 + y 2 < 10100
0 r < 10100 DEG: | | < 1010 RAD: | | < 180 1010 GRAD: | | < 1010 9 DEG
10
a=
b=
a=
b=
* Jumlah memori yang digunakan untuk kepentingan tampilan dalam editor WriteView, diukur dalam jumlah karakter (tidak termasuk nilai yang dimasukkan, ditunjukkan dalam diagram dengan )
r,
x, y
r= sx = sy = x=3 y = 46
RAD
r= sx = sy =
3 y
y = ? 3 @ U x = ? 46 @ V
46 x 24.61590706
DEC: | x | 9999999999 BIN: 1000000000 x 1111111111 0 x 111111111 PEN: 2222222223 x 4444444444 0 x 2222222222 OCT: 4000000000 x 7777777777 0 x 3777777777 HEX: FDABF41C01 x FFFFFFFFFF 0 x 2540BE3FF
A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance Attention: Your product with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. is marked with this Following the implementation by member states, private households within the EU states symbol. It means that may return their used electrical and electronic equipment to designated collection facilities used electrical and free of charge*. In some countries* your local retailer may also take back your old product electronic products free of charge if you purchase a similar new one. should not be mixed with general household *) Please contact your local authority for further details. waste. There is a If your used electrical or electronic equipment has batteries or accumulators, please separate collection dispose of these separately beforehand according to local requirements. system for these By disposing of this product correctly you will help ensure that the waste undergoes the products. necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling. 2. In other Countries outside the EU If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal. For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you dont purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch. B. Information on Disposal for Business Users. 1. In the European Union If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities. For Spain: Please contact the established collection system or your local authority for take-back of your used products. 2. In other Countries outside the EU If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.
ENGLISH
For Australia/New Zealand only: For warranty information please see www.sharp.net.au.