FT702LT Turbine Control Wind Sensor

Featuring Acoustic Resonance Sensing Technology

FT Technologies
www.fttech.co.uk

FT Technologies
Product Features
Developed for turbine control applications Patented Acoustic Resonance technology Solid-state design with no moving parts Combined speed and direction sensing Durable and rugged design Powerful heater for ice-prone areas Suitable for land and offshore installation Easy mounting on turbine RS485 and 4-20mA interface options ISO9001 designed and manufactured

Church Lane, Teddington, Middlesex, TW11 8PA, England Tel: +44 (0)20 8943 0801 Fax: +44 (0)20 8943 3283 Email: [email protected] Web: www.fttech.co.uk

High Reliability
Each aspect of the FT702LT design has been optimised for the demanding environment in which modern megawatt scale turbines are installed. Rigorous testing at the design stage, including advanced highly accelerated testing techniques such as HALT, means that the FT702LT can be trusted in the most demanding conditions. All production sensors are 100% wind tunnel tested and undergo powered burn-in testing to ensure that the highest levels of reliability are achieved in the field.

Anti-Icing Heater
For operation in ice-prone areas the FT702LT is fitted with a highly effective thermostatically controlled all-body heating system. A three element heater (one element located in the top of the sensor and two in the bottom) is used to ensure that the heating is evenly distributed over the entire surface area. The heat flux exceeds the Finnish Met. Institute guidelines of 0.4W/sq. cm.

Description
Measurement Principle
The FT702LT incorporates FT Technologies patented Acoustic Resonance sensing technology. This proven award-winning technology uses an acoustic (ultrasonic) signal which is resonated inside a small cavity to measure both wind speed and wind direction. Advantages of Acoustic Resonance include;
resonance effect boosts signal-to-noise ratio inherent compensation against fluctuations in
atmospheric temperature, pressure and humidity

Enhanced EMC and Lightning Protection


Located outside the protection of the turbine nacelle, wind sensors are exposed to high levels of electromagnetic interference from atmospheric disturbances such as static discharges and nearby lightning strikes. The FT702LT incorporates robust protection circuitry to protect it against these effects. (See Technical Specification for details of test levels). The sensor will survive undamaged lightning induced surges in excess of 4kA 8/20s. A detailed EMC test report is also available on request.

linear response vs. speed close transducer spacing results in very compact and
rugged sensor configurations

Easy Alignment
Mounting and aligning the sensor on the turbine is very straightforward. A machined flat on the sensor body defines the 0deg wind datum so that the sensor automatically aligns with the turbine axis.

solid state construction results in improved accuracy

Designed for Wind Turbine Applications


Accurate measurement of incident wind direction at the turbine is essential for optimum generating performance. The FT702LT provides measurement data for both turbine yaw control (wind direction) and start-up and shut-down (wind speed) of the turbine. With no moving parts to degrade or wear out, the FT702LT helps reduce costly unscheduled maintenance visits and shortens turbine down-time.

Flexible Interfacing
The FT702LT is available with either RS485 serial or 4-20mA current loop interface, allowing it to be used with virtually any turbine controller. A range of wind speed scaling factors is available for the 420mA option (See Ordering Information) so that the sensor can be used in retrofit applications without having to make any changes to the turbine controller.

FT702LT

Turbine Control Wind Sensor

Technical Specification
SENSOR PERFORMANCE1
MEASUREMENT PRINCIPLE WIND SPEED MEASUREMENT RANGE ACCURACY RESOLUTION WIND DIRECTION MEASUREMENT RANGE ACCURACY RESOLUTION ENVIRONMENT TEMPERATURE RANGE HUMIDITY Acoustic Resonance (compensated against variations in temperature, pressure and humidity) 0-50m/s 0.5m/s (0-15m/s), 4% (>15m/s) 0.1m/s 0 to 360 2 (within 10 of 0 datum), 4 (beyond 10 of 0 datum) 1 -40 to +85C (operating), -40 to +85C (storage) 0-100%

DATA I/O
RS485 OPTION
INTERFACE FORMAT DATA UPDATE RATE Digital RS485, galvanically isolated from power supply lines and case ASCII data, polled or continuous output modes 5 measurements per second

4-20MA OPTION
INTERFACE FORMAT READING UPDATE RATE 4-20mA CONFIGURATION PORT2 4-20mA, galvanically isolated from power supply lines and case One 4-20mA current loop for wind speed (see Ordering Information for scaling factors available) One 4-20mA current loop for wind direction (4-20mA = 0-360deg) 5 per second RS485 half duplex, non-isolated relative to power ground

POWER REQUIREMENTS
SUPPLY VOLTAGE SUPPLY CURRENT (HEATER OFF) SUPPLY CURRENT (HEATER ON) 20V to 30V DC (24V DC nominal) 25mA 6A (max) The heater is thermostatically controlled. Heater power consumption will depend on the heater energy required to keep the sensors temperature at a user determined set point. The heater and sensor power consumption is limited by default to 99W.3

PHYSICAL
WEIGHT MATERIAL I/O CONNECTOR MOUNTING METHOD 320g (max) Aluminium alloy, hard anodised 5-way (RS485 option), 8-way (4-20mA option) multipole connector Self aligning, single screw fixing

STANDARDS
TEMPERATURE RANGE ............................................ Cold EN 60068-2-1 (2007) & Dry Heat EN 60068-2-2 (2007) & Cycling EN 60068-2-14 (2009) HUMIDITY....................................................................... Stationary Humidity EN 60068-2-78 (2002) & Cyclic Humidity EN 60068-2-30 (2005) INGRESS PROTECTION ............................................. IP67, EN 60529 (1992) ENVIRONMENTAL .................................................... Corrosion ISO 9227 (2006) Neutral Salt Spray IEC 12944 C5-M High & Sand and Dust, DEF STAN 00-35 CL25 (2006) & Altitude EN 60068-2-13 (1999) & Solar Radiation EN 60068-2-5 (2000) VIBRATION AND SHOCK ........................................... Sinusoidal Vibration EN 60068-2-6 (2008) & Random Vibration EN 60068-2-64 (2008) & Drop test EN 60068-2-31 (2008) EMC (Full Test Report available on request) EMISSIONS: EN 61000-6-3:2007 CISPR 22:2005 Class B IMMUNITY: EN 61000-6-2:2005 ELECTROSTATIC DISCHARGE EN 61000-4-2:2001, 8kV (Contact Discharge), 15kV (Air Discharge) RADIATED RF INTERFERENCE EN 61000-4-3:2006, 80MHz-2.7GHz swept frequency FAST TRANSIENT BURSTS EN 61000-4-4:2004, 2kV Shielded cable, 4kV 24V DC power ports SURGE EN 61000-4-5:2006, 8kV Shielded cable, 4kV 24V DC power supply 500V line to line or earth CONDUCTED RF FIELD EN 61000-4-6:2006, 150kHz to 80MHz, 30Vrms, 80% AM (1kHz) POWER FREQUENCY M AGNETIC FIELD EN61000-4-8:1993, including A1:2001, 100A/m 50/60Hz PULSE MAGNETIC FIELD EN 61000-4-9:2000, 10kA/m 1.2/50s DAMPED OSCILLATORY WAVES MAGNETIC FIELD EN 61000-4-10:2001, Field Strength 500A/m 100kHz and1MHz VOLTAGE DIPS EN 61000-4-29:2001, 100% reduction for 3ms, 25% dip for 10s, 120% variation for 10s

NOTES:
1. 2. 3. All specifications subject to change without notice The Configuration Port is provided to allow the user to change the internal settings of the FT702LT/D and to perform diagnostic testing. This interface should only be used for configuration and test purposes. This interface is not intended for permanent connection to the turbine controller. The heater set point, current limit and maximum power limits can be configured by programming the sensors internal parameter settings

Outline Dimensions*

Ordering Information
Order code for RS485 interface: Order code for 4-20mA Interface:

FT702LT

FT702LT/D__

Append 2 digit wind speed scaling

30 m/s = 20mA 40 m/s = 20mA 50 m/s = 20mA 60 m/s = 20mA 70 m/s = 20mA

NOTES:
*

All dimensions in mm

The models available with scaling factors above 50m/s are intended for applications where the turbine controller wind speed scaling is preset and cannot easily be changed (this is often the case for retrofit applications). Because the maximum wind speed range of the FT702LT/D is 50m/s, for models with speed scaling above 50m/s the maximum output current is limited to a value equivalent to 50m/s

Information furnished by FT Technologies Ltd is believed to be accurate and reliable. However no responsibility is assumed by FT Technologies Ltd for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No licence is granted by implication or otherwise under any patent rights of FT Technologies Ltd. Drawing Number 2A9305, MAY2011

FT Technologies Ltd
Church Lane, Teddington, Middlesex, TW11 8PA, England. Tel: +44(0)20 8943 0801 Fax: +44(0)20 8943 3283 E-mail: [email protected] Web: http://www.fttech.co.uk