11.0545 Digital Deluxe Automatic Tyre Inflator Jamec Pem

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

DIGITAL AUTOMATIC TYRE INFLATOR

Operating Instructions
Part No. 11.0545
Thank you for selecting this Jamec Pem TABLE OF CONTENTS
Automatic Tyre Inflator. Please read this
Features........................................................ 2
manual before carrying out any installation
or service procedure. Components List.......................................... 2
Installation..................................................... 3
This manual is an integral and essential part
of the product, please keep it away from Warning......................................................... 3
damp, heat, dust, oils, do not remove, tear General Notes............................................... 3
or amend any parts of the manual for any Product Identification................................... 4
reason. It must be made available to the
Operation...................................................... 5
operator and to maintenance personnel,
also to ensure staff training. Troubleshooting............................................ 6
Calibration Certificate................................... 7
If you lose or damage the manual, ask the
manufacturer for a copy, quoting the Part Specifications............................................... 8
No. The manual must always remain with the Maintenance................................................. 8
machine, in the event of the machine being
Wiring Diagram............................................. 8
sold, it must be given to the new user.
The manufacturer reserves the right to change
product features at any time without notice.
COMPONENTS LIST
Please check and make sure that the following
FEATURES components are complete in the package.
• Units of measure bar, p.s.i., kPa, kg / cm2
1. Automatic Tyre Inflator with power cord
• Inflates to 0.5 - 10 bar, 1000 kPa, 145 p.s.i.,
2. 7.6 m (25 ’) Air Hose
10 kg / cm2
3. Hook and M6 x 38 screw kit (1pc)
• Large easy to read LCD display with audible
warning 4. User manual
• Tough aluminium die cast body 5. M6 x 38 screw 4pcs for wall mounting
• Individually calibrated and tested
(see calibration certificate)

2
INSTALLATION WARNING
1. Unpack the unit. To avoid the risk of personal injury,
2. H
 old the unit up on the wall and mark especially to the eyes, face or skin, DO NOT
where the four (4) holes are to be drilled. direct the air stream at any person, or any
part of the body.
3. Secure the unit using suitable fastener.
This equipment is not intended for use by
4. Connect the air supply to the unit.
children without adult supervision.
5. Connect the rubber hose as air outlet.
When using the OPS function, the sum
6. Connect the power supply. pressure must not exceed the tyre
manufacturer’s maximum inflation pressure.
Warning:
1. T
 his unit is connected directly to
compressed air and this air contains oil General notes
and water. Water is from condensation and •  uring extended inactivity, please
D
oil is from the compressor. Water and oil package the inflator and keep it away from
will destroy this device, so it is important damp, heat or impact, etc.
to filter them out first from the system, this
• After unpacking the inflator, the packing
means you must attach a filter prior to this
materials should be disposed of according
devices air connection.
to the laws and regulations applicable to
2. E
 lectrical connection should be carried the country being used.
out by qualified person strictly according
•  lease check carefully to ensure that no
P
to the related regulation applicable at the
part is damaged, so to ensure safe and
place where the inflator is used. normal operation.
3. To avoid equipment damage, •  he Automatic Tyre Inflator can be
T
never exceed the maximum inlet installed outside, but a shelter is
pressure or 10.5 bar / 1050 kPa / suggested, so to protect the equipment
150 p.s.i. / 10.5 kg / cm2 from the weather and extend the service
life.

3
1 PRODUCT IDENTIFICATION
CONTROL PANEL
2 3 1. Mounting Point (x 4)
4
2. - Target pressure control
3. + Target pressure control
4. Display
5. FLAT TYRE / CONFIRM
Flat tyre mode air Start/Stop control;
5 6 Function Select Confirm
6. Unit Option
Unit of measure select;
Over Pressure Setting set control

Fig. 1 Control panel

CONNECTIONS
7. Power cable
8. Pressurised Air Inlet
9. Air Hose Outlet
10. Exhaust Plug
11. Buzzer (Audible Warning)
7 8 9 10 11

Fig. 2 Connections

12 13
DISPLAY
12. Unit of measure
13. Pressure display
14. Function selection
15. Rolling bar

14 15
Fig. 3 Display

4
OPERATION Inflation and Deflation:
1. Press + or - to select target pressure.
The device includes the OPS (Over Pressure
Setting) function which allows for the tyre’s 2. C
 onnect with tyre, ensure no air leaks,
pressure to be set very high and then reduced inflator will start automatically.
to the pre-determined pressure. This is very
handy for use when a new tyre is fitted to a 3. W
 hen inflation is finished, the tyre inflator
rim. will stop automatically and BEEP to warn
users that inflation has reached target
Unit of measure select: pressure.
This device has four units of measure that can 4. Disconnect the air hose from tyre.
be chosen by the user:
• kPa - kilopascals
• bar Functions:
• p.s.i. - pounds per square inch 1. Press Unit Option to enter the function
• kg / cm2 - kilograms per square centimetre setting mode. After selecting the unit,
press Unit Option again to enter the
Once the unit is set here, it will become the OPS setting directly, press Unit Option
default unit for following usage. three times and the device will exit out
of the setting mode without saving the
1. P
 ress Unit Option and SET will be
selection.
shown on the LCD screen and the unit will
2. When OPS function is on, the device will
be flashing.
inflate to target pressure plus OPS value
2. Press + or - to choose the unit. first, then deflate to tyre pressure desired,
for example:
3. P
 ress CONFIRM to confirm unit of A final target of 32 p.s.i. or 2.2 bar with an
measure. OPS setting of 16 p.s.i. or 1.1 bar gives
a sum of 48 p.s.i. or 3.3 bar. This sum of
Set OPS: 48 p.s.i. or 3.3 bar is the Over Pressure
1. P
 ress Unit Option twice, SET and OPS setting for the tyre. The tyre will inflate
will be shown on the LCD screen, OPS will to the sum value and deflate to the final
be flashing target pressure.
3. If tyre pressure is lower than 3 p.s.i. or 0.2
2. Press + or - to choose the OPS value. bar, the device will not start automatically.
3. P
 ress CONFIRM to confirm. If OPS value Press FLAT TYRE for 2 seconds to start
is not zero, OPS will be displayed at the manually.
LCD screen. 4. During inflation, the device will check tyre
pressure automatically, the rolling bar
shows inflation/deflation in progress and
left to right means inflating, right to left
means deflating.

5
troubleshooting

Problem Possible Cause Solution

Check the pneumatic connection and


Air leak Leak in the connection
make sure of seals
The inflator works,
Obstruction in the filters or in air system Clean the filters and check the air tube
but no air inflated
Inflation does not Check the hose connection, make sure
Air hose improperly connected
start, although the that no air leaks
pressure is set and
the hose is connected Tyre pressure is below 0.2 bar (3 p.s.i.) Press FLAT TYRE
to the tyre
The unit deflates
The exhaust plug is blocked Remove and clean the exhaust plug
very slowly
Er1 Pressure sensor broken Power off, change pressure sensor
Replace hose connector or re-connect
Er2 Unstable pressure, faulty hose connector
hose to the tyre
Connected tyre pressure is too high
Er3 Stop inflating the tyre
> 13 bar (188.5 p.s.i.)
Refer to wiring diagram and connect
Er4 Wrong connections at air inlet and outlet
magnetic valve accordingly
Er5 Low voltage Check the power supply
Er6 Calibration error Unit requires calibration
Er7 Calibration error Unit requires calibration
Er8 Air supply lower than set inflate pressure Stop inflating this tyre

6
Calibration Certificate
This Digital Automatic Tyre Inflator has been calibrated in its normal working position on test
equipment with an accuracy that is traceable to International Standards according to: 86/217/EEC

Allowable Tolerance
±0.08 up to and including 4 bar
BAR ±0.16 between 4 bar and 10 bar inclusive
±0.25 greater than 10 bar
±1.2 up to and including 58 p.s.i.
p.s.i. ±2.3 between 58 and 145 p.s.i. inclusive
±3.6 greater than 145 p.s.i.

Test result

Reference Pressure

BAR P.s.i.

Display Pressure

BAR P.s.i.

Serial Number:

Date:

7
SPECIFICATIONS MAINTENANCE
Die cast aluminium Daily Maintenance
Case The device does not require a particular
enclosure
maintenance routine but a check of the
Degree of protection IP66 pneumatic connection is suggested frequently
Dimensions 23L x 27W x 8.5H cm to make sure of correct air supply, the use of
Shipping weight 5.5 kg an air pre-filter is essential for this unit to
operate properly.
0.5 - 10 bar
Inflation range (1000 kPa / 145 p.s.i. / Special Maintenance
10 kg / cm2) This is a sensitive piece of equipment if you
Accuracy ±0.02 bar (±0.3 p.s.i.) have an error that cannot easily be fixed
Max. inlet air supply 10.5 bar (150 p.s.i.) please contact an authorised service agent.

Supply voltage 110~240V AC (50~60 Hz)


Wattage 12 W max
Working temperature -10 - 50° C
up to 95% RH
Relative humidity
non-condensing

wiring diagram

Distributed by
Primus Australia Pty Ltd.
Bundoora VIC 3083
For more information contact
Customer Service on 1300 555 197 www.jamecpem.com.au