Triple-Band Combiner: 690 - 862 MHZ 880 - 960 MHZ 1427 - 3800 MHZ

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Triple-Band Combiner

690 – 862 MHz 880 – 960 MHz 1427 – 3800 MHz

• Can be used as a combiner near the BTS or in a reciprocal AUTO-


function near the antenna SENSE
• Very low insertion loss
• Enables feeder sharing
• Designed for co-siting purposes
• Integrated auto-sense technology for automatic DC / AISG
detection and bypass functionality.
Combine Mode (near BTS):
In combine mode, the auto-sense combiner has the ability
to operate in three different functions (more details on next
page):
1. First In - First Out Function
2. Priority Controlled Function
3. Exclusive User Function
Single Unit Double Unit
Split Mode (near antenna):
In split mode, the auto-sense combiner automatically
detects connected Antenna Line Devices and bypasses or
stops the DC / AISG signal accordingly.
A detailed manual about Auto-Sense technology can be
downloaded on our homepage.
• Available as a single unit, or for XPol antennas as a double
unit
• Suitable for indoor and outdoor applications
• Wall or mast mounting
• Built-in lightning protection
690 - 862 880 - 960 1427 - 3800
Technical Data
Type No.
DC/AISG transparency
1. First In - First Out Function 78211827 78211828
2. Priority Controlled Function 78211827V01 78211828V01
3. Exclusive User Function 78211827V02 78211828V02
Unit Single Double
Pass band
Band 1 MHz 690 – 862
Band 2 MHz 880 – 960
Band 3 MHz 1427 – 3800
Insertion loss
Port 1 l Port 4 dB < 0.35 (690 - 852 MHz); < 0.6 (852 - 862 MHz)
Port 2 l Port 4 dB < 0.6 (880 - 890 MHz); < 0.35 (890 - 960 MHz)
Port 3 l Port 4 dB < 0.15 (1427 - 3800 MHz)
Isolation
Port 1 dB > 50 (880 - 960 MHz); > 90 (1427 - 3800 MHz)
Port 2 dB > 60 (690 - 862 MHz); > 90 (1427 - 3800 MHz)
Port 3 dB > 65 (690 - 862 MHz); > 60 (880 - 960 MHz)
VSWR < 1.25
Impedance Ω 50
Input power
Band 1 / Band 2 / Band 3 W < 200 / < 200 / < 200 (1427 – 2700 MHz); < 100 (2700 – 3800 MHz)
Intermodulation products dBc < –160 (3rd order; with 2 x 20 W)
Temperature range °C | °F −40 ... +60 | −40 ... +140
Connectors 4.3-10 female
Application Indoor or outdoor (IP 66)
DC/AISG transparency
Port 1, 2, 3 l Port4 mA Auto-sense (max. 2000)
Lightning protection kA 3, 10/350 µs pulse
Mounting Wall mounting: With 4 screws (max. 8 | 0.315 diameter)
Mast mounting: With additional clamp set
Weight kg | lb Single Unit: 5 | 11.0 / Double Unit: 9.9 | 21.8
Dimensions (w x h x d) mm | in Single Unit: 222 x 222 x 87 | 8.7 x 8.7 x 3.4; Double Unit: 222 x 222 176 | 8.7 x 8.7 x 6.9
(without connectors, without mounting brackets)
Packing size mm | in Single Unit: 405 x 295 x 170 | 16.0 x 11.6 x 6.7
Double Unit: 405 x 295 x 260 | 16.0 x 11.6 x 10.3

320
Triple-Band Combiner

690 – 862 MHz 880 – 960 MHz 1427 – 3800 MHz

Accessories (order separately) Typical Attenuation Curves


Clamp Set
Diagram 1

Multi-Band Combiners
Diagram 2
Type No. Clamp set suitable
for mast diameter of
734360 34 - 60 mm
734364 120 - 140 mm
734365 45 - 125 mm

DC stop

Diagram 3

Type No. Description


78211000 DC stop
50-Ohm load
78210484 50-Ohm load

Auto-Sense Combiner functions for the interconnection


of different base stations (BTS)
(Installation close to the BTS – Combine Mode)
First In - First Out function
If the First In – First Out function is set, the first base station
(BTS) which supplies the auto-sense combiner with DC Diagram 4
voltage at any input port is bypassed to the common port.
The DC from further base stations will be ignored.
Priority Controlled function
If the Priority Controlled function is used, a corresponding
priority table is set ex-factory (shown below). In case DC /
AISG signals are applied to two or more input ports simulta-
neously, the BTS with higher priority will be bypassed to the
common port. Any DC signal from a lower prioritised input
port will not be bypassed.

LTE 2600 highest Priority for DC-AISG 1


LTE 800 2
LTE 700 3
UMTS 2100 4
UMTS 900 5 Please Note:

As a result of more stringent legal regulations and judgements regarding


GSM 1800 lowest Priority for DC-AISG 6 product liability, we are obliged to point out certain risks that may arise
when products are used under extraordinary operating conditions.

Exclusive User function Extraordinary operating conditions, such as heavy icing or exceptional
dynamic stress (e.g. strain caused by oscillating support structures), may
If the Exclusive User function is set in the combiner, the first result in the breakage of a mast mounted device or even cause it to fall to the
base station which supplies an appropriate DC voltage at ground.
any input port is bypassed to the common port. If a second These facts must be considered during the site planning process.
DC/AISG signal is erroneously fed into the combiner, then The combiners are designed to operate under the environmental conditions
none of the DC/AISG signals will be allowed to bypass to as described in ETS 300 019-1-4 class 4.1 E and have passed environmental
tests as recommended in ETS 300 019-2-4.
the common port.
The installation team must be properly qualified and also be familiar with
A detailed manual about Auto-Sense technology can be the relevant national safety regulations.
downloaded from our website. The details given in our data sheets have to be followed carefully when
installing the combiners and accessories.
Please note: If the combiner is mounted near the antenna
The limits for the coupling torque of RF connectors
(split mode), the behaviour is independent of any of the must be obeyed. The coupling torque at 4.3-10
prioritisation functions described above. In this mode, the connectors is 5 - 8 Nm.
auto-sense combiner automatically detects Antenna Line Terminate unused inputs with a suitable 50-Ohm
Devices at the output ports and bypasses or blocks the DC/ load.

AISG signal at each port accordingly. Any previous datasheet issues have now become
invalid.

321