Power Analyzer is a tool to accurately measure the characteristics of electric power generators,
power transformational deals. The accurate measurement of the actual power inverters, motor
drivers, office equipment, supplies and equipment on hand. Today, power analyzers have many
applications, for example, can be loaded energy systems single-phase or three-phase symmetrical
systems measure capable of measuring parameters such as voltage, current, watts, Spooky, active
power, reactive power, kVA. As well as the ability to connect to a computer to record the minimum
and maximum. With the advances in energy efficiency and power, increasing demand for accurate
and reliable measurement of electric energy there. Stable and reliable analyzer that enables
engineers to power dissipation in inverters, motor, lighting and power circuits to prevent.In electrical
systems and power measuring device for measuring and analyzing the watts and there kW. The
multi-function meter or Power Analyzer Multi-Function Power analyzers, which are direct and
alternating voltage AC, DC, AC or DC intensity and phase rotation measures. Analyzer
Multifunctional Power or Power Analyzer Multi-Function As for measuring energy used, can also be
used for harmonic analysis and phase rotation. Depending on the use, power analyzers are
available in various types.Anaz·h measurement and analysis of pay. Pavrmtrha Powermeter devices
that are used to calculate the power, energy, active and reactive power, power factor and voltage
measurement, flow have been designed As you know, the introduction of energy per unit time is
measured in units of Watts and The electricity is obtained by multiplying the voltage and current.
However, the electrical system, especially during intermittent need to analyze many factors are
involved in the production and transmission of electric energy consumption Drtjhyzat very effective.
Power analyzers or harmonic analyzers for the measurement of such parameters such as voltage,
current, harmonic distortion and many power quality parameters were designed. It is equipped with
software for analysis, as well as probes and clamps for measuring current and voltage phase.
Now let's introduce the Ziegler power analyzer type mfm 3430.
The Ziegler mfm 3430 is a panel mounted 96 x 96mm DIN Quadratic Digital metering system for the
Energy (Active / Reactive / Apparent) . The instrument integrates accurate measurement technology
(Voltage& Current measurements are True RMS up to 15th Harmonic) with 3 line 4 digits Ultra high
brightness LED display. Ziegler mfm 3430 can be configured and programmed at site for the
following : PT primary CT Primary, CT Secondary (5A or 1A). The front panel has two push buttons
through which the user may scroll through the available measurement readings ,reset the energy
(Import /Export) Min /Max (System Voltage and System Current) and configure the product.
In normal operation the user is presented with one of the measurement reading screens out of
several screens .These screens may be scrolled through one at a time in incremental order by
pressing the “ Up key ”and in decremental order by pressing “ Down key.” 1 : System screen
(System Voltage ,System Current , System Active Power) 2 : Phase Angle ,Frequency, Sys. Power
Factor 3 : System Power (Reactive, Apparent ,Active) 4 : Active Energy(Import) 5 : Active Energy
(Export) 6 : Reactive Energy(Import) 7 : Reactive Energy(Export) 8 : Apparent Energy 9 : Min Sys
Voltage & Current 10 : Max Sys Voltage& Current 11 : Voltage & Current % THD Etc.
Programming
The following sections comprise step by step procedures for configuring the 3430 for individual user
requirements. To access the set-up screens press and hold the Key simultaneously for 5
seconds .This will take the User into the Password Protection Entry Stage . With this way you can do
Value , .Current Transformer Primary Value , Current Transformer Secondary Value , Pulse Rate ,
Resets , Address Setting , Pulse Duration , Low Current noise cutoff , Assignment of Energy to pulse
output 1 , Assignment of Energy to pulse output 2 , RS 485 Baud Rate , RS 485 Parity Selection ,
This module provides two d.c .isolated outputs. There are two output options 1) Two 0 - 1mA outputs
, internally powered.2) Two 4 - 20mA outputs , internally powered. The 0- 1mA output module has an
0V return on each end of the 4 way connector. On both modules the output signals are present on
pins A1 & A2. These outputs can be individually assigned to represent any one of the measured and
displayed Parameters.
Refer diagrams
RS 485 ( ModBus ) Output
3430 supports MODBUS (RS485) RTU protocol ( 2-wire). Connection should be made using twisted
pair shielded cable .All" A "and" B "connections are daisy chained together .The screens should also
be connected to the“ Gnd ”terminal .To avoid the possibility of loop currents , an Earth connection
should be made at one point on the network.Loop (ring) topology does not require any termination
load .Line topology may or may not require terminating loads depending on the type and length of
cable used .The impedance of the termination load should match the impedance of the cable and be
at both ends of the line .The cable should be terminated at each end with a 120 ohm (1/4 Watt min.)
resistor . RS 485 network supports maximum length of 1.2km .Including the Master ,a maximum of
options available, 1 (One Pulse Output : Relay 1 can be configured either to Active ) Import / Export (
energy or Reactive ( Import / Export ) energy or Apparent energy .2 (Two Pulse Output : Here it is
possible to assign Relay 1 and Relay 2 to Active ( Import / Export ) energy or Reactive ( Import /
Export ) energy or Apparent energy. The pulse divisor and pulse width(duration) can be
configured .When two pulse outputs are fitted ,they share a common divisor value and pulse width.
NOTE: If system power is selected in W then default pulse rate is 1 pulse per Wh (upto 3600W) . If
the system power is scaled in kW then default pulse rate is 1 pulse per kWh (upto 3600 kW) .If the
system power is over 3600 kWh then pulse rate is 1 pulse per MWh.
Phaser Diagram
displays Active power( P )with ” + “ ( positive sign ) , the connection is “ Import ” . When 3430
Installation
Mounting is by four side clamps ,slide the side clamps through side slot till side clamp gets firmly
locked in a groove (Refer fig.) Consideration should be given to the space required behind the
instrument to allow for bends in the connection cables. As the front of the enclosure conforms to
IP54 it is protected from water spray from all directions ,additional protection to the panel may be
obtained by the use of an optional panel gasket .The terminals at the rear of the product should be
protected from liquids. The 3430 should be mounted in a reasonably stable ambient temperature
and where the operating temperature is within the range -10 to 55 C. Vibration should be kept to a
minimum and the product should not be mounted where it will be subjected to excessive direct
sunlight.
Caution
1.In the interest of safety and functionality this product must be installed by a qualified
engineer ,abiding by any local regulations. 2. Voltages dangerous to human life are present at some
of the terminal connections of this unit .Ensure that all supplies are de-energised before attempting
any connection or disconnection.3.These products do not have internal fuses therefore external
This product has been designed to meet the certification of the EU directives when installed to a
good code of practice for EMC in industrial environments, e g . 1.Screened output and low signal
input leads or have provision for fitting RF suppression components ,such as ferrite absorbers ,line
filters etc ,.in the event that RF fields cause problems.Note: It is good practice to install sensitive
electronic instruments that are performing critical functions ,in EMC enclosures that protect against
electrical interference which could cause a disturbance in function. 2.Avoid routing leads alongside
cables and products that are ,or could be ,a source of interference. 3.To protect the product against
permanent damage ,surge transients must be limited to 2kV pk .It is good EMC practice to suppress
differential surges to 2kV at the source .The unit has been designed to automatically recover in the
event of a high level of transients .In extreme circumstances it may be necessary to temporarily
disconnect the auxiliary supply for a period of greater than 5 seconds to restore correct operation.
4.ESD precautions must be taken at all times when handling this product.
Wiring
Input connections are made directly to screw-type terminals with indirect wire pressure. Numbering
is clearly marked in the plastic moulding .Choice of cable should meet local regulations .Terminal for
both Current and Voltage inputs will accept up to 2x3 mm2 diameter cables. Note : It is
Auxiliary Supply
3430 should ideally be powered from a dedicated supply, however it may be powered from the
signal source ,provided the source remains within the limits of the chosen auxiliary voltage.
Fusing
It is recommended that voltage lines are fitted with 1 amp HRC fuses.
Earth/Ground Connections
For safety reasons ,CT secondary connections should be grounded in accordance with local
regulations.
Connection Diagrams