Tyco ADC Network

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

Fiber Cable Assemblies and Accessories

Patch Cords, IFC Assemblies, Attenuators, FasTerm Connectors and Adapters

2nd Edition

Table of Contents
Introduction ........................................................................................................................................ 1 Patch Cords

Fiber Cable Assemblies and Accessories


102880AE 1/11

TracerLight Connector Identification System .......................................................................................... 2 TracerLight Singlemode or Multimode Patch Cords (Simplex and Duplex) ............................................... 3 Singlemode Patch Cords (Simplex and Duplex)........................................................................................ 4 Multimode Patch Cords (Simplex and Duplex) ......................................................................................... 5 Singlemode Multifiber Patch Cords (4- to 24-fibers)................................................................................ 6 Multimode Multifiber Patch Cords (6- and 12-fibers) .............................................................................. 7

Intrafacility Fiber Cable (IFC) Assemblies


Stranded IFC Assemblies ......................................................................................................................... 8 Ribbon IFC Assemblies ............................................................................................................................ 9 Singlemode IFC Assemblies ................................................................................................................... 10 Multimode IFC Assemblies .................................................................................................................... 11

Attenuators
In-Line Attenuators................................................................................................................................ 12

FasTerm Connectors
Singlemode and Multimode Connectors, Tool Kits and Accessories ...................................................... 13

Adapters
Simplex and Duplex Adapters................................................................................................................ 14

Accessories
Fiber Connector/Adapter Cleaning Kit................................................................................................... 15

Fiber Optic Specifications........................................................................................................16-18 Fiber Optic Glossary..................................................................................................................19-20

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Fiber Cable Assemblies and Accessories


Introduction Comprehensive Product Line
ADC produces a wide variety of fiber cable assemblies and accessories designed to meet the specific application needs of our customers. From patch cords, multifiber assemblies and connectors to adapters and attenuators, ADC is the choice for the essential products necessary to meet the requirements of todays high-speed networks.
ADCs patch cord manufacturing personnel are certified through ADCs rigorous internal fiber patch cord training processes.

Fiber Cable Assemblies and Accessories

Advanced Manufacturing Processes


Advanced manufacturing processes allow us to meet some of the strictest specifications in the industry at prices comparable to those of less stringently produced components. ADCs innovative polishing techniques, rigorous evaluation of epoxies, serialized tracking and the strictest testing processes make us an industry leader in fiber components.

Insertion Loss at 1310/1550 nm Any Two Randomly Mixed Pairs 16 14 12


Frequency
Maximum Value: 0.2 db Typical Value: 0.09 db UPC Connector

10 8 6 4 2 0 0.1 0.025 0.075 0.125 0.175 0.2


-53

Quality Assurance
ADC tests every singlemode connector and applies a bar code traceable to the exact insertion loss and return loss for that termination. This aids in the documentation of the exact losses in the network. The bar code system also stores information about the materials used and the manufacturing process applied to produce the patch cord. These records are retained for your reference for over three years. ADC's polishing process ensures consistently low insertion and return loss values. Insertion and return loss values are affected by the endface geometries of the fiber connector. ADC's fiber assemblies meet Telcordia GR-326 industry requirements for quality and performance.

Insertion Loss (dB) Return Loss at 1310/1550 nm Any Two Randomly Mixed Pairs 70
Frequency

60 50 40 30 20 10 0
-61 -60 -59 -58 -57 -56

Minimum Value: 50 dB UPC Connector

102880AE

-55

-54

Reflectance (dB) 50 40 30 20 10 0 -10 -20 -30 -40 -50

50 40

USL

USL

24 22 Millimeters 20 18 16 14 12

USL

1/11

Microns

30 20 10 0 Target Apex Offset

Nanometers

LSL Fiber Recess

10

LSL Radius of Curvature

UPC Connector Measurements

www.te.com/adc

+1-952-938-8080

1-800-366-3891

-52

0.225

0.05

0.15

Patch Cords

TracerLight Connector Identification System Power Source and Patch Cords


ADCs innovative TracerLight connector identification system offers a quick and accurate method of identifying the termination point of optical patch cords. Each end of a TracerLight patch cord features a flashing light allowing technicians to visually trace individual patch cords from one end to the other without pulling or affecting the patch cord. The TracerLight power source is easily attached to the TracerLight component on one end of the patch cord. This causes the LED on each end to begin flashing rapidly. As a result, the distant end of the patch cord can be quickly and easily identified without interruption of service or disturbance of the optical signal path. Available in any standard length or connector style, TracerLight patch cords have the same functions, optical performance and stringent environmental requirements as our standard patch cords. TracerLight patch cords are installed in the same manner as standard patch cords and can be pulled through ADCs FiberGuide fiber cable management system with ease. The compact power source is comprised of a lightweight, plastic flashlight body featuring two AA batteries and a printed circuit board (PCB). It provides approximately 80 hours of continuous service and features 1-hour auto-off. The end of battery life is indicated by a slowing of the blink rate. Ordering Information
Description TracerLight power source TracerLight plus launch cable (for use with a tone generator) Catalog Number FTL-PS FTL-TGLC

Fiber Cable Assemblies and Accessories

TracerLight Connector Identification System

TracerLight Power Source FTL-PS

1/11

102880AE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Patch Cords
Simplex

TracerLight Singlemode or Multimode Patch Cords

Catalog Number Connector Style (first end) FTL- __ / __ - __ __ __ __ M

Fiber Cable Assemblies and Accessories

Singlemode 7 E 2 C M 9 P SC ultra polish SC angled polish FC ultra polish LC ultra polish LC angled polish SC LC Assembly Length 001-020 1-20 meters in 1 meter increments 025-065 25-65 meters in 5 meter increments 070-150 70-150 meters in 10 meter increments Cable Type (1.7 mm) Singlemode D P A J G Reduced bend radius singlemode (yellow)* Reduced bend radius singlemode (blue)* 50/125 m multimode (orange) 50/125 m laser optimized to 300 m multimode (aqua) 62.5/125 m multimode (orange)

Multimode

Connector Style (second end) Singlemode 7 E 2 C M 9 P SC ultra polish SC angled polish FC ultra polish LC ultra polish LC angled polish SC LC

Multimode

Multimode

Ordering Examples FTL-7/7-D003M: Reduced bend radius singlemode simplex patch cord with SC connectors on both ends, 3 meters in length. FTL-9/9-A005M: Multimode simplex patch cord with SC connectors on both ends using 50/125 m fiber, 5 meters in length.

Duplex
Connector Style (first end) Singlemode 7 E 2 C M 9 P SC ultra polish SC angled polish FC ultra polish LC ultra polish LC angled polish SC LC

Catalog Number FTL- __ __ __ __ __ __ M Assembly Length 001-020 025-065 070-150 1-20 meters in 1 meter increments 25-65 meters in 5 meter increments 70-150 meters in 10 meter increments

102880AE

Cable Type (1.7 mm) Singlemode Z R Reduced bend radius dual zip singlemode (yellow)* Reduced bend radius dual zip singlemode (blue)* 50/125 m dual zip multimode (orange) 50/125 m laser optimized to 300 m multimode (aqua) 62.5/125 m dual zip multimode (orange)

Multimode

Connector Style (second end) Singlemode 7 E 2 C M 9 P SC ultra polish SC angled polish FC ultra polish LC ultra polish LC angled polish SC LC H E K

Multimode

1/11

Multimode

Ordering Examples FTL-7CZ010M: Reduced bend radius singlemode dual zip patch cord with SC to LC connectors, 10 meters in length. FTL-PPE010M: Multimode dual zip patch cord with LC connectors on both ends using 50/125 m fiber, 10 meters in length. * Not a substitute for well-engineered cable management.

Other connector styles are available upon request. Please contact ADC Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Patch Cords

Singlemode Patch Cords (Simplex and Duplex)


All patch cords undergo stringent testing for both insertion loss and return loss at the factory before shipment to ensure that only quality product is delivered to the customer.
SC ultra polish SC angled polish FC ultra polish LC angled polish LC ultra polish

Fiber Cable Assemblies and Accessories

ADC offers ultra physical contact (UPC) polish on the SC, FC, and LC connector styles. Angled polish is available on the LC connector and the SC connector styles. Angled polish should be used in applications that require better control of return loss. ADC has tight tolerances regarding the rotation of the ferrule to maintain low insertion loss values.

Connector Types

Catalog Number __ __ - __ - __ - __ M Cable Option FPC FPT Connector on both ends (patch cord) Connector on one end (pigtail) Assembly Length 1-20 25-65 1-20 meters in 1 meter increments 25-65 meters in 5 meter increments

70-150 70-150 meters in 10 meter increments Fiber Type S P


LEAVE BLANK

Cable Type Standard singlemode M F 9 2 T MW FW 9W 2W TW 2.0 mm single 1.7 mm single 900 m 2.0 mm dual zip 1.7 mm dual zip 2.0 mm single 1.7 mm single 900 m 2.0 mm dual zip 1.7 mm dual zip

Standard singlemode Reduced bend radius singlemode (blue)* 2.0 mm standard singlemode

Singlemode Connector Type1 SPSC SC ultra polish simplex APSC SC angled polish simplex SDSC SC ultra polish duplex2 SPFC SPLC SDLC APLC FC ultra polish simplex LC ultra polish simplex LC ultra polish duplex2 LC angled polish simplex

Reduced bend radius

102880AE

Ordering Examples FPC2-SPSC-10M: Singlemode 2.0 mm dual zip patch cord with SC ultra polish connectors on both ends, 10 meters in length with standard breakout length of 0.31 m (12") on both ends.
1

1/11

For hybrid patch cords, enter both connector types in this field and separate them with a slash mark; remove 's' from the ultra polish option. FPCF-SPSC/PLC-S-10M: Singlemode 1.7 mm simplex patch cord with SC ultra polish connector on one end and LC ultra polish connector on the other end, 10 meters in length.

One connector per end; requires dual zip cable

* Not a substitute for well-engineered cable management. Other connector styles are available upon request. Please contact ADC Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Patch Cords

Multimode Patch Cords (Simplex and Duplex)


Multimode patch cords are available with the LC small-form-factor connector and the SC connector. These patch cords are assembled using the same advanced manufacturing processes as the singlemode, ensuring the highest quality standards.

Fiber Cable Assemblies and Accessories

LC-SC Multimode Patch Cord

Catalog Number __ __ - __ - __ - __ M Cable Option FPC Connector on both ends (patch cord) FPT Connector on one end (pigtail) Assembly Length 1-20 25-65 70-150 1-20 meters in 1 meter increments 25-65 meters in 5 meter increments 70-150 meters in 10 meter increments

Cable Type Standard multimode M F 9 2 T 2.0 mm single 1.7 mm single 900 m 2.0 mm dual zip 1.7 mm dual zip

Fiber Type A B 50/125 m multimode 62.5/125 m multimode

Multimode Connector Type1 MSC MDSC MLC MDLC SC simplex SC duplex2 LC simplex LC duplex2

Multimode 50/125 m 10G laser optimized to 300 m (aqua) MA FA 2A TA 2.0 mm single 1.7 mm single 2.0 mm dual zip 1.7 mm dual zip

102880AE

Ordering Examples FPCM-MSC-B-7M: Multimode simplex 2.0 mm patch cord with SC connectors on both ends, 62.5/125 m fiber type, 7 meters in length.
1

For hybrid patch cords, enter both connector types in this field and separate them with a slash mark.

1/11

FPCM-MSC/MLC-A-3M: Multimode simplex 2.0 mm patch cord with SC connector on one end and LC connector on the other end, 50/125 m fiber type, 3 meters in length.
2

One connector per end; requires dual zip cable

Other connector styles are available upon request. Please contact ADC Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Patch Cords

Singlemode Multifiber Patch Cords (4- to 24-fibers)


Singlemode multifiber patch cords are available with 4, 6, 12 or 24 tight buffered 1.7 mm fibers enclosed in a standard wall outer jacket. Each 1.7 mm fiber is coded for easy identification of individual fibers. Central strength member, and aramid yarn; PVC jacket thickness 0.89 mm. Patch cords are also available with 6, 8 or 12 tight buffered 900 m fibers with a thin softwall outer jacket. No central strength member or aramid yarn; PVC jacket thickness 0.64 mm.
Catalog Number FPM-0 __ / __ - __ __ __ __ M- __ __ / __ __ Connector Type (1st and 2nd end) 0 7 E 2 K M Stub (only on 2nd end) SC ultra polish SC angled polish FC ultra polish LC ultra polish LC angled polish Assembly Length 001-020 1-20 meters in 1 meter increments 025-065 25-65 meters in 5 meter increments 070-150 70-150 meters in 10 meter increments Cable Type D R E P AH L N F M FP GP 4-fiber standard wall with 1.7 mm subunits 4-fiber reduced bend radius with 1.7 mm subunits (blue) 6-fiber standard wall with 1.7 mm subunits 6-fiber soft wall with 900 m buffered fiber 8-fiber standard wall with 1.7 mm subunits 8-fiber soft wall with 900 m buffered fiber 8-fiber reduced bend radius with 1.7 mm subunits (blue) 12-fiber standard wall with 1.7 mm subunits 12-fiber soft wall with 900 m buffered fiber 12-fiber reduced bend radius with 1.7 mm subunits (blue) 24-fiber reduced bend radius with 1.7 mm subunits (blue) Breakout Length X
LEAVE BLANK

Cable Jacket, PVC 0.89 mm thick Aramid Yarn

Central Strength Member 1.7 mm Fiber subunit

PVC Jacket 0.64 mm thick

Buffered Fiber 900 m

Fiber Cable Assemblies and Accessories

Ripcord

Ripcord

Standard Wall (4-Fiber Shown)

Soft Wall (12-Fiber Shown)

Length in inches Both ends 0.31 m (12")

102880AE

AD 24-fiber standard wall with 1.7 mm subunits

Ordering Example FPM-07/0-P005M: Singlemode multifiber patch cord with SC ultra polish connectors on one end, no connectors on the other end (pigtail), 6-fiber soft wall, 5 meters long with standard breakout. Other connector styles and breakout lengths are available upon request. Please contact ADC Technical Assistance Center.

1/11

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Patch Cords

Multimode Multifiber Patch Cords (6- and 12-fibers)


Multimode multifiber patch cords are available with 6 and 12 tight buffered 900 m fibers with a soft wall outer jacket. No central strength member or aramid yarn; PVC jacket thickness 0.64 mm.
PVC Jacket 0.64 mm thick Buffered Fiber 900 m

Fiber Cable Assemblies and Accessories

Soft Wall (12-Fiber Shown)

Catalog Number MFPM- __ / __ - __ __ __ __ M- __ __ / __ __ Connector Type (1st and 2nd end) 0 9 P Stub (only on 2nd end) SC LC Assembly Length Cable Type PB NB WC NA NH NG 6-fiber soft wall, 62.5/125 m 12-fiber soft wall, 62.5/125 m 6-fiber soft wall, 50/125 m 12-fiber soft wall, 50/125 m 6-fiber soft wall, 50/125 m laser optimized to 300 m (aqua) 12-fiber soft wall, 50/125 m laser optimized to 300 m (aqua) 001-020 1-20 meters in 1 meter increments 025-065 25-65 meters in 5 meter increments 070-150 70-150 meters in 10 meter increments

Breakout Length X
LEAVE BLANK

Length in inches Both ends 0.31 m (12")

102880AE

Ordering Example MFPM-9/P-PB008M: Multimode multifiber patch cord with SC connectors on one end and LC ultra polish connectors on the other end, 6-fiber soft wall cable, 8 meters in length with standard breakout. Other connector styles and breakout lengths are available upon request. Please contact ADC Technical Assistance Center.

1/11

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Intrafacility Fiber Cable (IFC) Assemblies


Stranded IFC Assemblies
Intrafacility fiber cable (IFC) is a multifiber cable designed for use within a building. Generally, it will be constructed without metallic strength members and is designed to meet the fire resistant characteristics required in the central office. The number of fibers range from 12 to 144. Standard IFC assemblies are riser rated and meet UL-1666 OFNR. Two types of IFC are available: stranded and ribbon. With stranded cable, individual 900 m fibers make up the construction of the cable. The fibers are bundled into subunits of 6- or 12-fibers each. Each subunit is identified and the individual fibers within the subunits are color-coded. Stranded IFC diameters increase in proportion with the fiber counts.

Fiber Cable Assemblies and Accessories

IFC Assembly

Ripcord (2) PVC Cable Jacket 6-Fiber Subunit (See Detail A) Mylar Tape Central Strength Members

Detail A
PVC Jacket Buffered Fiber Aramid Yarn

See Detail C

24-Fibers with 6-Fiber Subunits

12-Fiber Subunit (See Detail B) Mylar Tape PVC Cable Jacket Ripcord (2) Central Strength Members

Detail B
PVC Jacket Aramid Yarn
See Detail C

102880AE

Buffered Fiber

72-Fibers with 12-Fiber Subunits

1/11

PVC Jacket

Detail C Buffered Fiber


Buffer Coating

Buffered Fiber 900 m Aramid Yarn

Cladding Core

12-Fibers Shown

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Intrafacility Fiber Cable (IFC) Assemblies


Ribbon IFC Assemblies
Ribbon cable consists of multi-fibers arranged in ribbons. Each ribbon contains 12-fibers and is identified as a subunit. The fibers which comprise the ribbons are color-coded for identification. With the construction of ribbon cable, the fibers are located in the center of the cable and the outer jacket provides the strength and protection of the cable. Three benefits are derived from the construction: the outer jacket is more robust than stranded cable; the outer diameter of the cable remains constant over the range of fiber counts available; and ribbon cable may be used with mass fusion type splicing.
Fiber Color-Code Chart 1 2 3 4 Blue Orange Green Brown 5 6 7 8 Slate White Red Black 9 10 11 12 Yellow Violet Rose Aqua
1 2 3 4 5 6 7 8 9 10 11 12 1 - Blue 2 - Orange 3 - Green 4 - Brown 5 - Slate 6 - White 7 - Red 8 - Black 9 - Yellow 10 - Violet 11 - Rose 12 - Aqua See Detail B PVC Outer Jacket Fiberglass Strength Members PVC Inner Jacket

Fiber Cable Assemblies and Accessories

See Detail A

Mylar Tape Ribbon Air Core

Detail A

Detail B
Coating

Cladding

Core

1/11

102880AE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Intrafacility Fiber Cable (IFC) Assemblies


Singlemode IFC Assemblies
Catalog Number IFC - __ /__ __ __ __ __ - __

Fiber Cable Assemblies and Accessories

Connector Type (1st and 2nd end) 0 7 2 E K M Stub (only on 2nd end) SC ultra polish FC ultra polish SC angled polish LC ultra polish LC angled polish

Breakout/Panel Type1
LEAVE BLANK

8" FCM FL2, 12 exit up or down FL2, 24 exit up or down FL2, 48 exit up or down FL2, 72 exit up FL2, 96 exit up FL2, 72 exit down FL2, 96 exit down NGF, 96- and 144-position LSX, 72- and 96-position

2A 2B 2C 2D 2E 2F 2G NG LA

Cable Type A B 2 V L EH NA HA JA DS LA LH
1

12-fiber stranded 24-fiber stranded 48-fiber stranded 72-fiber stranded 96-fiber stranded 144-fiber stranded 12-fiber ribbon 24-fiber ribbon 48-fiber ribbon 72-fiber ribbon 96-fiber ribbon 144-fiber ribbon

Assembly Length for Connector to Stub 016 16 m (50') 023 031 046 061 092 122 153 23 m (75') 31 m (100') 46 m (150') 61 m (200') 92 m (300') 122 m (400') 153 m (500')

077 77 m (250')

For competitors panel products, ADC recommends using the FCM breakout length (1.8 m = 6'). Standard lengths for connectors on both ends up to 150 meters. For information on ADC's FL2000 (FL2) FCM or LSX panel products and Next Generation Frame (NGF) Fiber Termination Blocks, call ADC Technical Assistance Center.

Assembly Length for Connectors on Both Ends2 XXX Length in meters Example: 010 = 10 meters 125 = 125 meters

102880AE

Additional fiber counts, lengths and connector styles are available upon request. Please contact ADC Technical Assistance Center.

Clamp Position Breakout Length Fanout Length

Assembly Length

Clamp Position Breakout Length Fanout Length

1/11

Connector

IFC Cable Cable Clamp Multifiber Subunits Subunit DesignationLabel

Labels

Cable Clamp Multifiber Subunits Subunit Designation Label

Connector

www.te.com/adc

+1-952-938-8080

1-800-366-3891

10

Intrafacility Fiber Cable (IFC) Assemblies


Multimode IFC Assemblies
Catalog Number MIFC - __ / __ __ __ __ __ __ - __

Fiber Cable Assemblies and Accessories

Connector #1 Type 9 P SC LC

Breakout/Panel Type1
LEAVE BLANK

8 FCM FL2, 12 exit up or down FL2, 24 exit up or down FL2, 48 exit up or down FL2, 72 exit up FL2, 96 exit up FL2, 72 exit down FL2, 96 exit down NGF, 96- and 144-position

2A 2B 2C 2D 2E 2F 2G NG

Connector #2 Type 0 9 P Stub SC LC

Cable Type AB 12-fiber stranded 62.5 m BB VB LB FT AD VZ VE FZ 24-fiber stranded 62.5 m 72-fiber stranded 62.5 m 96-fiber stranded 62.5 m 144-fiber stranded 62.5 m 24-fiber stranded 50/125 m 144-fiber stranded 50/125 m 72-fiber stranded plenum laser optimized to 300 m, 50/125 m (aqua) 144-fiber stranded plenum laser optimized to 300 m, 50/125 m (aqua) Assembly Length for Connector to Stub 016 16 m (50') 023 031 046 061 092 122 153 23 m (75') 31 m (100') 46 m (150') 61 m (200') 92 m (300') 122 m (400') 153 m (500')

AC 12-fiber stranded 50/125 m VA 72-fiber stranded 50/125 m

077 77 m (250')

Assembly Length for Connectors on Both Ends2 XXX Length in meters Example: 010 = 10 meters 125 = 125 meters

102880AE

For competitors panel products, ADC recommends using the FCM breakout length (1.8 m = 6'). Standard lengths for connectors on both ends up to 150 meters. For information on ADC's FL2000 (FL2) panel products and Next Generation Frame (NGF) Fiber Termination Blocks, call ADC Technical Assistance Center. Additional fiber counts, lengths and connector styles are available upon request. Please contact ADC Technical Assistance Center.
Clamp Position Breakout Length Fanout Length Assembly Length

Clamp Position Breakout Length Fanout Length

1/11

Connector

IFC Cable Cable Clamp Multifiber Subunits Subunit DesignationLabel

Labels

Cable Clamp Multifiber Subunits Subunit Designation Label

Connector

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11

Attenuators

In-Line Attenuators
A fiber optic attenuator is an optical device that induces a calibrated fixed loss between two connectors, which dampens, or attenuates the fiber optic signal. Attenuation is required if an optical signal has too much power, exceeding the operating range of the equipment, which causes saturation at the receiver and induces system errors or failures. ADCs full line of attenuators is manufactured to meet the demands of your network. In-line attenuators are installed between an adapter and a connector; they are fused attenuators, providing exceptional optical performance.

Fiber Cable Assemblies and Accessories

In-Line FC Attenuator

In-Line SC Attenuator

Adapter

In-Line Connector/ Attenuator Patch Cord Attenuation Tolerance 5 dB 0.75 dB >5 dB 10%

Ordering Information
Description LC ultra polish 05 dB 10 dB 15 dB 20 dB SC ultra polish 05 dB 10 dB 15 dB 20 dB SC angled polish 05 dB FOA-INASC05 FOA-INASC10 FOA-INASC15 FOA-INASC20 FOA-INFC05 FOA-INFC10 FOA-INFC15 FOA-INFC20 10 dB 15 dB 20 dB FC ultra polish 05 dB 10 dB 15 dB 20 dB FOA-INSC05 FOA-INSC10 FOA-INSC15 FOA-INSC20 FOA-INLC05 FOA-INLC010 FOA-INLC015 FOA-INLC020 Catalog Number*

1/11

102880AE

* Other attenuation values and connector styles are available upon request. Please contact ADC Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

12

FasTerm Connectors
Singlemode and Multimode FasTerm Connectors, Tool Kits and Accessories
FasTerm connectors are available with 62.5/125 m or 50/125 m multimode fiber and 9/125 m singlemode fiber. They come equipped with a pre-radiused zirconia ceramic ferrrule and can be installed in less than three minutes with standard fiber optic tools (per Bellcore specifications). FasTerm connectors offer all of the advantages of epoxy-based connectors, without the need for access to electricity andcuring ovens, the mixing of epoxies or use of syringes. The kit comes complete and self-contained. Each connector kit will accommodate 3.0 mm, 1.7 mm or 900 m cable. Ordering Information
Description Multimode FasTerm connector SC connector Singlemode FasTerm connector SC connector FC connector * Includes strain relief boots. FTC-SCS111 FTC-FCS111 FTC-SCM111 Catalog Number*

Fiber Cable Assemblies and Accessories

FasTerm Connector

Tool Kit
Ordering Information
Description FasTerm tool kit Multimode tool kit Singlemode SC tool kit* Singlemode FC tool kit* FTC-KIT001-SCST FTC-KIT002-SC FTC-KIT002-FC FasTerm Tool Kit Catalog Number

102880AE

*Each tool kit is identical except for the polishing puck. Additional polishing pucks may be purchased to expand the capabilities of a singlemode kit.

Accessories
Ordering Information
Description Catalog Number FTC-CNSM01 FTC-CNSM02 FTC-CRIMP2 FTC-SCOPE-200X Multimode consumables kit (100 terminations); connectors not included Singlemode consumables kit*; connectors not included Crimp tool Inspection scope (200x)

1/11

*ADC recommends that one consumable kit be used for every 25 singlemode connector terminations.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

13

Adapters

Simplex and Duplex Adapters


ADCs bulkhead adapters are available for all standard connector types in both singlemode and multimode. The adapters are color coded allowing easy identification of the adapter type.

Fiber Cable Assemblies and Accessories

The adapter sleeve aligns the ferrules and holds them in place. All singlemode and multimode adapters include zirconia alignment sleeves. Zirconia sleeves provide tight tolerances, generally required for angled physical contact (APC) connectors, but also excellent for ultra physical contact (UPC) and multimode connectors. LC small-form-factor adapters are available as duplex, enabling two connectors to be used in the same footprint as the SC connector.
Adapters

Ordering Information
Description Simplex adapters Singlemode SC Singlemode SC - no flange Singlemode FC - round adapter Multimode SC Multimode SC- no flange Singlemode LC Singlemode LC - angled polish, no flange Singlemode SC - angled polish Duplex adapters Singlemode SC Multimode SC Singlemode LC no flange Multimode LC Singlemode SC - angled polish Singlemode LC - angled polish FBA-DSCNF FBA-DMSCNF FBA-DLC-Z-NF FBA-DMLCNF FBA-DASCZNF FBA-ALCZ FBA-SC FBA-SCNF FBA-FR FBA-MSC FBA-MSCNF FBA-LC-Z-NF FBA-ALCZNF FBA-ASCZ Catalog Number*

1/11

102880AE

* Other connector styles are available upon request. Please contact ADC Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

14

Accessories

Fiber Connector/Adapter Cleaning Kit


The fiber connector/adapter cleaning kit contains all the items required to adequately clean fiber connectors and adapters. The performance of an optical fiber system is largely dependent on the fiber connector cleaning procedures followed prior to installation. It is suggested that all the connectors and adapters be cleaned before making any connections. The kit cleans approximately 500 connectors or adapters.

Fiber Cable Assemblies and Accessories

Ordering Information
Description Fiber connector/adapter cleaning kit Includes: Instruction sheet Lint-free wipes Isopropyl alcohol Cotton swabs Lint-free pipe cleaners Oil-free compressed air FPC-CLNKIT

Cleaning Kit Catalog Number

This kit contains flammable alcohol and compressed air. For this reason, it can be shipped by surface method only.

1/11

102880AE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

15

Fiber Optic Specifications


Optical Performance
Singlemode Ultra Polish Connectors (UPC) Insertion Loss (1310 and 1550 nm) Return Loss (1310 and 1550 nm) Fiber Recess Apex Offset Radius of Curvature Singlemode Angled Polish Connectors (APC) Insertion Loss (1310 and 1550 nm) Return Loss (1310 and 1550 nm) Polished Endface Radius Fiber Recess Apex Offset Endface Angle Multimode Ultra Polish Connectors Insertion Loss (1300 nm) Return Loss (1300 nm) SC 0.2 dB max. 0.09 dB typical -57 dB min. 50 nm 50 m max. 10-25 mm SC 0.35 dB max. 0.15 dB typical -65 dB min. 5 - 15 mm -100 to +50 nm 50 m 8 0.5 SC 0.3 dB max. -20 dB min. FC 0.2 dB max. 0.09 dB typical -57 dB min. 50 nm 50 m max. 10-25 mm LC 0.3 dB max. 0.1 dB typical -55 dB min. -100 to +50 nm 50 m max. 10-25 mm LC 0.35 dB max. 0.15 dB typical -65 dB 5 - 12 mm 50 nm 50 m 8 0.5 LC 0.3 dB max. -20 dB max.

Fiber Cable Assemblies and Accessories

Mechanical and Environmental Chararacteristics


Every patch cord manufactured by ADC is designed to pass rigorous qualification testing that includes: EIA/TIA Industry Standards according to Fiber Optic Test Procedures (FOTP). Item Specifications Temperature shock Humidity Temperature life Mating durability Vibration EIA/TIA Test FOTP-3 FOTP-5 FOTP-4 FOTP-21 FOTP-11 Item Specifications Cable flex Cable retention Cable twist Impact EIA/TIA Test FOTP-1A FOTP-6 FOTP-36 FOTP-2

1/11

102880AE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

16

Fiber Optic Specifications


Assembly Length Guide Patch Cords
Assembly Length
Length 1 to 15 m +15 m Tolerance +16 cm/-0 cm +1%/-0 cm

Fiber Cable Assemblies and Accessories

Multifiber Patch Cords


Length 1 to 15 m +15 m Tolerance +16 cm/-0 cm +1%/-0 cm

Assembly Length

IFC Assemblies
Stranded Length 1 to 15 m +15 m Ribbon Length 1 to 20 m +20 m Tolerance +16 cm/-0 cm +1%/-0 cm Tolerance +15 cm/-0 cm +90 cm/-0 cm

Assembly Length

1/11

102880AE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

17

Fiber Optic Specifications


Connector Dimensions

Fiber Cable Assemblies and Accessories

56 mm (2.21")

51 mm (2")

9.1 mm (.36")

9.1 mm (.36")

FC 2.0 mm Connector

FC 900 m Connector

64 mm (2.5") 5.6 mm (.22")

32 mm (1.24")

5.6 mm (.22")

LC 2.0 mm Connector

LC 900 m Connector

102880AE

53 mm (2.08")

56 mm (2.21")

7.4 mm (.29")

7.4 mm (.29")

1/11

SC 2.0 mm Connector

SC 900 m Connector

Other connector styles are available upon request. All connectors available in 2.0 mm, 1.7 mm and 900 m cable. Please contact ADC Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

18

Fiber Optic Glossary


Adapter A device used for joining two fiber optic connectors together. Coating A material that is put over the core and cladding of an optical fiber to protect it from the environment. Color Coded Cable Cable having color coded insulation on the conductors to aid identification. Connector Hardware installed on cable ends to provide physical and optical cable attachment to a transmitter, receiver or another cable. A junction which allows an optical fiber or cable to be repeatedly connected or disconnected to a device such as a source or detector. Core The light-conducting portion of a fiber defined by its high refractive index. The core is normally in the center of a fiber bounded by concentric cladding of lower refractive index. Fan-Out Used to provide a transition from ribbon fibers to individual fiber connection ports. Ferrule The alignment sleeve portion of an optical connector; aligns the end of the fiber. Standard connectors have a 2.5 mm ferrule diameter; small-form-factor connectors use 1.25 mm. In-line Attenuator Installed between an adapter and a connector. It adds attenuation to optical signals. Insertion Loss The total optical power loss caused by the insertion of an optical component such as a connector, splice or coupler.

Fiber Cable Assemblies and Accessories


102880AE 1/11

Angled Polish Angled Physical Contact (APC) is a term used to refer to a connector polished at a slight angle, which typically provides back reflections (return loss) greater than 65 dB. Attenuation The decrease of power from one point to another. It is caused by absorption, fiber imperfection, scattering and bending loss. In optical fibers, the power loss per unit length is expressed logarithamically in decibels per kilometer (dB/km) at a specific wavelength. Attenuator Optical device that induces a calibrated fixed loss in the fiber optic system. Bend Radius Minimum radius a fiber can bend before the risk of breakage or increase in attenuation. Breakout The point on a multifiber cable where the outer jacket is cut to expose the cable subunits. Buffer Material used to protect optical fiber from physical damage. Bundle Many individual fibers contained within a single jacket. Also a group of buffered fibers distinguished in some fashion from another group in the same cable core. Cable Assembly Fiber optic cable that has connectors installed on one or both ends. Cladding The material surrounding the core of an optical fiber which promotes total internal reflection.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

19

Fiber Optic Glossary


Intrafacility Fiber Cable (IFC) A generic term referring to a multifiber cable designed with properties required in a central office, including the requirement that the cable be fire retardant. Cables are available in ribbon or stranded fiber configuration with varied fiber counts. Jacket A layer of material, generally plastic, that surrounds an optical fiber to protect it from physical damage. Unlike the cladding, the jacket is physically distinct from the fiber core. Modes Individual paths in optical waveguides. Singlemode fiber has only one mode, the fundamental mode, while multimode fiber has several hundred modes. The upper limit to the number of modes is determined by the core diameter of the waveguide. Multimode Fiber An optical fiber whose core diameter is large compared with the optical wavelength - contains more than one mode. Patch Cord An optical fiber with a connector on each end. Also referred to as a jumper. Pigtail An optical fiber cable with a connector on one end. Plenum Cable Cable made from flame-retardant material that generates little smoke. Generally installed in plenum air ducts. Return Loss A measurement of the light reflected back to the source at an optical interface. Riser Cable Cable made from flame-retardant material intended for use in riser shafts without the use of conduit. Cable material will prevent the carrying of fire from floor to floor. Singlemode Fiber An optical waveguide in which only one mode propagates due to its small core diameter of approximately 8 microns. Ultra Polish Ultra Physical Contact (UPC) is a term used to refer to connectors with a flat polish which provide back reflections (also referred to as Return Loss) of greater than 50 dB and typical insertion losses of 0.2 dB. Wavelength A parameter of the light used in a fiber optic system. Because the attenuation of a fiber is highly dependent on the wavelength of the light traveling through it, optimum performance (i.e. minimum attenuation) can be achieved only by operating at one or two specific wavelengths. The specific wavelength at which the light is most transparent is called a window.

1/11

102880AE

Fiber Cable Assemblies and Accessories

www.te.com/adc

+1-952-938-8080

1-800-366-3891

20

Fiber Optic
Index
I
IFC.............. ................................................ 10 FTC-SCOPE-200X ........................................ 13 FTC-SCS111................................................ 13 FTL.............................................................. 3 FTL-PS ........................................................ 2 FTL-TGLC .................................................... 2

Fiber Cable Assemblies and Accessories

FBA-ALCZ ................................................... 14 FBA-ASCZ ................................................... 14 FBA-DALC-Z................................................ 14 FBA-DASCZNF............................................. 14 FBA-DLC-Z-NF ............................................. 14 FBA-DLCNF ................................................. 14 FBA-DMLCNF .............................................. 14 FBA-DMSCNF.............................................. 14 FBA-DSCNF ................................................. 14 FBA-DSCZNF ............................................... 14 FBA-FR ........................................................ 14 FBA-FRZ-AR ................................................ 14 FBA-LC ....................................................... 14 FBA-LC-Z-NF ............................................... 14 FBA-MSC .................................................... 14 FBA-MSCNF ................................................ 14 FBA-SC ....................................................... 14 FBA-SCNF ................................................... 14 FBA-SCZ ..................................................... 14 FBA-SCZNF ................................................. 14 FOA-INASC05 ............................................. 12 FOA-INASC10 ............................................. 12 FOA-INASC15 ............................................. 12 FOA-INASC20 ............................................. 12 FOA-INFC05................................................ 12 FOA-INFC10................................................ 12 FOA-INFC15................................................ 12 FOA-INFC20................................................ 12 FOA-INLC05................................................ 12 FOA-INLC010.............................................. 12 FOA-INLC015.............................................. 12 FOA-INLC020.............................................. 12 FOA-INSC05 ............................................... 12 FOA-INSC10 ............................................... 12 FOA-INSC15 ............................................... 12 FOA-INSC20 ............................................... 12 FPC.............. ............................................... 4,5 FPC-CLNKIT ................................................ 15 FPM.............. .............................................. 6 FPT.............. ................................................ 4,5 FTC-CNSM01 .............................................. 13 FTC-CNSM02 .............................................. 13 FTC-CRIMP2 ............................................... 13 FTC-FCS111 ................................................ 13 FTC-KIT001 ................................................. 13 FTC-KIT002-FC............................................ 13 FTC-KIT002-SC ........................................... 13 FTC-SCM111 .............................................. 13

M
MFPM.............. ........................................... 7 MIFC........................................................... 11

1/11

102880AE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

21

Tyco Electronics Corporation 8000 Purfoy Road Fuquay Varina, NC 27526-9349 Tel: 919-557-8900 Fax: 919-557-8498 www.tycoelectronics.com www.us.telecomosp.com

Fiber Cable assemblies and aCCessories

ADC, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors. While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this document, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult Tyco Electronics for the latest dimensions and design specifications.

Tyco Electronics Corporation. All rights reserved. 102880AE 1/11 Revision 2011, 2010, 2009, 2007, 2006, 2003, 2002, 2001

You might also like