Data sheet 7KM2112-0BA00-3AA0

SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 690 V, L-N: 400 V, 5 A,
3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS, apparent/
active/reactive energy, class 0.5 acc. to IEC61557-12 or class 0.5s acc. to
IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals

Model
product brand name SENTRON
Measurements
measuring procedure
● for voltage measurement RMS
● for current measurement TRMS
type of measured value detection complete
voltage curve Sinusoidal or distorted
measurable line frequency
● initial value 45 Hz
● full-scale value 65 Hz
operating mode for measured value detection automatic line Yes
frequency detection
operating mode for measured value detection
● set at 50 Hz No
● set to 60 Hz No
Supply voltage
design of the power supply Wide-range power supply
type of voltage of the supply voltage AC/DC
supply voltage at AC 95 ... 240 V
supply voltage at DC 110 ... 340 V
Degree of protection protection class
protection class IP on the front IP65
operating resource protection class when installed II
Suitability
suitability for operation Installation in stationary panels in closed rooms
Product Functions
product function
● voltage measurement Yes
● current measurement Yes
● active power measurement Yes
● reactive power measurement Yes
● frequency measurement Yes
Display and operation
design of the display LCD
height of the display 54 mm
width of the display 72 mm
color of the background of the display white
national language on the display screen is supported ger, en, fr, spa, ita, por, tur, chi
number of keys 4

7KM21120BA003AA0 Subject to change without notice


7/14/2024
Page 1/6 © Copyright Siemens
Communication
transfer rate minimum 10 000 kbit/s
transfer rate maximum 10 000 kbit/s
number of interfaces according to Fast Ethernet 1
type of electrical connection of the fast Ethernet interface RJ45 (8P8C)
protocol at the Ethernet interface is supported MODBUS TCP
Fault limits
reference condition for metering accuracy according to IEC62053-22 and IEC62053-23
formula for relative total measurement inaccuracy
● for measured variable voltage +/- 0.3 %
● for measured variable current +/- 0.2 %
● for measured variable output factor +/- 0,5 %
● for measured variable active energy Cl. 0.5 acc. to... IEC62053-22
● for measured variable reactive energy Class 2 according to IEC61557-12 and/or IEC62053-23
Inputs Outputs
number of digital inputs 1
number of digital outputs 1
digital output version switching or pulse output function
operating voltage as output voltage at DC maximum permissible 30 V
output current
● at digital output with signal <0> maximum 0.2 mA
● at digital output for signal <1> maximum 27 mA
internal resistance at the digital outputs 55 Ω
standard for pulse emitter according to IEC62053-31
pulse duration
● initial value 30 ms
● full-scale value 500 ms
adjustable time period minimum 10 ms
switching frequency at digital output maximum 17 Hz
property of the output short-circuit proof Yes
measuring category for digital signals CATII
Measuring inputs
measurable supply voltage between (PE)N and L at AC 400 V
maximum rated value
measurable supply voltage between (PE)N and L at AC
● minimum 40 V
● maximum 480 V
measurable supply voltage between the line conductors at AC 690 V
maximum rated value
measurable supply voltage between the line conductors at AC
● minimum 70 V
● maximum 831 V
voltage measuring range extension with external voltage yes
transformers
line conductors and neutral conductors internal resistance for 1.05 MΩ
voltage measurement
measuring category for voltage measurement CAT III
measurable current
● 1 at AC rated value 1A
● 2 at AC rated value 5A
relative measurable current at AC
● minimum 1%
● maximum 120 %
current measuring range extension with external current Yes
transformers
zero point suppression for current measurement 0.1 ... 10 %
measuring category for current measurement CATIII
Connections
type of connectable conductor cross-sections
● at the measurement inputs for voltage solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● at the measurement inputs for voltage finely stranded with 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
core end processing

7KM21120BA003AA0 Subject to change without notice


7/14/2024
Page 2/6 © Copyright Siemens
● at the measurement inputs for voltage for AWG cables 2x 20 to 14
solid
● at the measurement inputs for current solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● at the measurement inputs for current finely stranded with 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
core end processing
● at the measurement inputs for current for AWG cables 2x 20 to 14
solid
type of electrical connection
● at the measurement inputs for voltage screw-type terminals
Mechanical Design
size of Power Monitoring Device size 96
height 96 mm
width 96 mm
depth 56 mm
installation depth 51 mm
net weight 451 g
mounting position vertical
Environmental conditions
ambient temperature during operation
● minimum -10 °C
● maximum 55 °C
ambient temperature during storage
● minimum -25 °C
● maximum 70 °C
relative humidity at 25 °C without condensation during operation 95 %
maximum
installation altitude at height above sea level maximum 2 000 m
Certificates
certificate of suitability as EC Declaration of Conformity IEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN
EN 61010-1:2002 with "Berichtigung 1"
reference code according to EN 61346-2 P
Approvals Certificates
General Product Approval EMV Test Certificates

Confirmation Type Test Certific-


ates/Test Report

other Environment

Miscellaneous Confirmation Environmental Con-


firmations

Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (catalogues, leaflets,...)
http://www.siemens.com/energy-automation
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=7KM2112-0BA00-3AA0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/7KM2112-0BA00-3AA0
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=7KM2112-0BA00-3AA0
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

7KM21120BA003AA0 Subject to change without notice


7/14/2024
Page 3/6 © Copyright Siemens
96.1 56

SIEMENS SENTRON PAC3200


96.1

7KM2112-OBAOO-3AA0

21.7 17.5

-P V1 V2 V3 VN L/+ N/- FE DI- DI+ DO- DO+


-X2 -X4
LAN

-X3

-X1 IL1/k IL1/l IL2/k IL2/l IL3/k IL3/l

last modified: 6/30/2024

7KM21120BA003AA0 Subject to change without notice


7/14/2024
Page 4/6 © Copyright Siemens
7KM21120BA003AA0 Subject to change without notice
7/14/2024
Page 5/6 © Copyright Siemens
7KM21120BA003AA0 Subject to change without notice
7/14/2024
Page 6/6 © Copyright Siemens

You might also like