Eaton EX RT Datasheet Eng

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Pulsar Series

UPS

Eaton EX RT
7/11 kVA single phase input / single phase output 5/7/11 kVA three phase input / single phase output
Double conversion (on-line)
High performance UPS for single phase applications.

Maximum availability

Hot swappable UPS and battery modules Internal bypass and maintenance bypass included as standard The UPS can be connected to two independent electrical sources (sources 1 and 2 can be common or separate) Large input voltage range without draining the battery: 230 V + 20% to - 30% single phase and 400 V + 15% to - 20% three phase Batteries tested automatically at regular intervals and protected against deep discharge N+1 redundancy supported by two single units

Eaton EX RT

Wide choice of backup times

From 10 minutes to 2 hours with battery modules or up to 8 hours using the CLA charger module Automatic recognition of battery modules and easy battery installation with battery integration system

Ergonomy

Multilingual LCD display and LEDs for rapid view of the UPS status and the operating log Self diagnosis and fault messages

Battery Integration system

Can be integrated into even the most demanding environments:


Computer

Tower / 6U Rack convertible Comprehensive range of Power Distribution Units for convenient power distribution within the rack Compatible with all types of generator set Can be integrated into building management systems Steel casing Operating temperature up to 45 C Meets Marine vibration test requirements

Advanced protection for: Rack servers enclosures and industrial environment

Industrial

EATON Product Catalogue

Eaton EX RT UPS
Slot for Eaton minislot communication card 9-pin D output connector RJ11 port for remote emergency power off Connectors for automatic detection of battery module(s) RS 232 communication port Connector for EXB modules Manual bypass for hot maintenance Output connectors Source switch 1 Source 1 connector Source 2 connector Battery circuit breaker

Technical Specifications
Active power kVA / kW Technology Rated input voltage Input voltage range Input, output frequency range Output voltage / THDU Overall efficiency THDI Crest factor / short circuit current Overload capacity Temperature operating

5 kVA 5 kVA / 4 kW (single phase input not available for 5kVA)

7 kVA 7 kVA / 4.9 kW

11 kVA 11 kVA / 8 kW

On-line double conversion with PFC (Power Factor Correction) system (applicable to single phase models)) 200/208/220/230/240/250 V single phase 380/400/415V three phase (- 30%; + 20%) 230 V; (- 20%, + 15%) 400 V 40-70 Hz, 50 / 60 HZ autoselection, frequency converter as a standard 200/208/230/240 /250 V +/- 2%; THDU < 2% Normal mode 91%, eco mode 97% THDI < 5% (single phase input value) 3:1 / 100 A 3:1 / 100 A 3:1 / 150 A >150% 500 ms; 150% 30 s; 125% 60 s; 110% 120 s 45C for 8 Hrs (at nominal output power for 230 V or 400V input and 230V output), 40C continuous Standard: 1 power mod. 3U + 1 battery mod. EXB 3U = 6U Standard + 1 battery mod. EXB 3U = 9U Standard + 2 battery mod. EXB 3U = 12U Terminal block for 13 mm2 (stranded cable) or 10 mm2 (solid cable) 6 voltage free contacts DB9 2 A 48 V DC, 1 RS 232, RJ11 for remote emergency power off 1 slot for communication card IEC 62040-1/IEC 60950/UL 1778 and CSA 22.2 (applicable to single phase models) IEC 62040-2; EN 50091-2; FCC class A (applicable to single phase models), EMC B level (option for single phase model) UL (applicable to single phase models)/TV, GS mark,CB, C-Tick,CE, IEC 68-2-6 (vibration tests Marine approval) 444.5 x 261.2 x 700 mm 89.5 kg 261.2 (6U) x 444.5 x 700 mm 97.3 kg 444.5 x 130.6 x 700 / 130.6 (3U) x 444.5 x 700 mm 24.2 kg 444.5 x 130.6 x 650 / 130.6 (3U) x 444.5 x 650 mm 64.5 kg 130.6 (3U) x 444.5 x 650 mm / 12 kg / 87 kg 444.5 x 261.2 x 700 mm 88.3 kg / 89.5 kg 261.2 (6U) x 444.5 x 700 mm 96.1 kg / 97.3 kg 444.5 x 130.6 x 700 / 130.6 (3U) x 444.5 x 700 mm 23 kg / 24.2 kg 444.5 x 130.6 x 650 / 130.6 (3U) x 444.5 x 650 mm 64.5 kg 130.6 (3U) x 444.5 x 650 mm / 12 kg / 87 kg 444.5 x 261.2 x 700 mm 94.2 kg / 95.3 kg 261.2 (6U) x 444.5 x 700 mm 102 kg / 103.1 kg 444.5 x 130.6 x 700 / 130.6 (3U) x 444.5 x 700 mm 24.9 kg / 26 kg 444.5 x 130.6 x 650 / 130.6 (3U) x 444.5 x 650 mm 68.5 kg 130.6 (3U) x 444.5 x 650 mm / 12 kg / 87 kg

Back-up times* at 70% load


From 10 up to 15 minutes From 15 up to 20 minutes From 40 up to 65 minutes

Connection
Input /output Port type Slot

Communication Standards and certification


Performance and safety EMC Certification

Dimensions H x W x D / Weight (single phase input / three phase input)


Eaton EX RT standard backup tower Eaton EX RT standard backup Network Pack rack mounting Eaton EX RT Power module Battery module Eaton EXB RT EX RT CLA module / EX RT Transformer

Customer Service & Support


1 year warranty, including battery Warranty+

Free standard replacement for faulty units, including the batteries Optional 3-years warranty (depending on the country please visit www.eaton.com/powerquality)

* (typical values after 3 discharge cycles, batteries 3-5 years, longer backup times available using the CLA or EXB module, ask for details)

Part Numbers
Input voltage
Eaton EX RT standard back-up time Tower Network Pack Rack Format (1) EXB RT battery module / EXB RT battery module with EPO built-in Eaton EX RT Power module (for use with EXB or CLA module) Rack kit for Eaton EX RT Power module / Eaton EXB RT and CLA Eaton EX RT Transformer module Eaton EX RT CLA module (2 to 8 hours) EX RT Battery Integration System (2) EMC B level filter module EX RT PDU 19 rack format (3) 1.8 m battery connection cable (4) UPS Control, remote UPS monitor display Single-phase / / / / / / / / / / / /

EX RT 5 Three-phase 68 054 68 056 68 078 / 68 079 68 057 68 001 / 68 002 68 003 68 004 68 005 / 66 857 68 006 66 080

EX RT 7 Single-phase 68 070 68 072 68 078 / 68 079 68 075 68 001 / 68 002 68 003 68 004 68 005 68 008 66 857 68 006 66 080 Three-phase 68 074 68 076 68 078 / 68 079 68 077 68 001 / 68 002 68 003 68 004 68 005 / 66 857 68 006 66 080

EX RT 11 Single-phase 68 110 68 112 68 118 / 68 119 68 115 68 001 / 68 002 68 003 68 004 68 005 68 008 66 857 68 006 66 080 Three-phase 68 114 68 116 68 118 / 68 119 68 117 68 001 / 68 002 68 003 68 004 68 005 / 66 857 68 006 66 080

1: the Network Pack version includes standard back-up time unit + Network Management Card + rack mounting kit. 2: trolley capacity 8 modules max, casters, adjustable feet. 3: 12 sockets 4 X IEC 16 A + 8 X IEC 10 A. 4: for non standard inter-module spacing.

In the interests of continuous product improvement all specifications are subject to change without notice. 2009 Eaton Corporation, All Rights Reserved, April 2009.

You might also like