Sentron PC 4200
Sentron PC 4200
Sentron PC 4200
Model
product brand name SENTRON
Product designation multimeter
Design of the product compact
Product type designation PAC4200
Type of measured value detection complete
Design of the power supply Wide-range power supply
Voltage
Measurable current / 1 / at AC / Rated value A 1
Measuring procedure / for current measurement TRMS
Supply voltage
Supply voltage frequency / Rated value
● minimum Hz 45
● maximum Hz 65
Type of voltage / of the supply voltage AC/DC
Measuring category / for supply voltage CATIII
Apparent power consumption
● with expansion module / maximum V·A 32
● without expansion module / typical V·A 11
Active power consumption
● with expansion module / typical W 11
● without expansion module / typical W 5.5
Relative symmetrical tolerance / of the supply voltage % 10
Protection class
Protection class IP
● on the front IP65
Operating resource protection class / when installed II
Electricity
Short-time current resistance (Icw) / limited to 1 s / A 100
Rated value
Measurable current / 2 / at AC / Rated value A 5
Suitability
Suitability for operation Installation in stationary control panels in closed
rooms
Adjustable time period / minimum ms 10
Product function
Product function
● Illuminance of display backlighting adjustable Yes
● Time-controlled reduction of the illuminance of Yes
display backlighting possible
● reactive power measurement Yes
Communication
Refresh time / at the interface
● for instantaneous values / typical ms 200
Number of active connections / at the Ethernet 3
interface
Number of logical ports / at the Ethernet interface / is 2
supported
Design of cable / connectable / Twisted pair Yes
Product function / at the Ethernet interface
● auto-MDI(X) Yes
● Autonegotiation Yes
● serial gateway Yes
Protocol
● at the Ethernet interface / is supported MODBUS TCP
● is supported MODBUS TCP
Transfer rate
● minimum kbit/s 10 000
● maximum kbit/s 100 000
● 1 / for Ethernet Mbit/s 10
● 2 / for Ethernet Mbit/s 100
Fault limits
Reference condition / for metering accuracy Acc. to IEC61557-12
Formula for relative total measurement inaccuracy
● for measured variable reactive energy Class 2 according to IEC61557-12 and/or IEC62053-
23
● for measured variable output +/- 0,5 %
Inputs Outputs
Input voltage / at digital input
● initial value for signal<1>-recognition V 19
● at DC / Rated value V 24
● at DC / maximum V 30
● Full-scale value for signal<0> recognition V 10
Number of digital outputs 2
Number of digital inputs 2
Digital output version switching or pulse output function
Type of switching output solid state
Type of electrical connection / at the digital outputs screw-type terminals
Type of electrical connection / at the digital inputs screw-type terminals
Input current / at digital input
● for signal <1> mA 4
Output current
● at digital output / with signal <0> / maximum mA 0.2
● at digital output / for signal <1> / maximum mA 27
● at digital output / for signal <1> / minimum mA 10
● at the digital outputs / at DC / limited to 100 ms mA 300
/ maximum
● at the digital outputs / at DC / maximum mA 100
Output delay / at digital output
● for signal <0> to <1> / maximum ms 5
● for signal <1> to <0> / maximum ms 5
Operating conditions for digital inputs / external Yes
voltage supply
Operating voltage / as output voltage / at DC / V 30
maximum permissible
Property of the output / Short-circuit proof Yes
Input delay time / at digital input
● for signal <0> to <1> / maximum ms 5
● for signal <1> to <0> / maximum ms 5
Internal resistance / at the digital outputs Ω 55
Measuring category / for digital signals CATI
Switching frequency / at digital output / maximum Hz 20
Transfer rate / 1 / for fast Ethernet Mbit/s 100
Connections
● Type of connectable conductor cross-section /
at the digital inputs
— for AWG conductors / solid 1x 24 ... 12
— solid 1x (0.2 ... 2.5 mm2), 2x (0.2 ... 1.0 mm2)
— finely stranded / with core end processing 1x (0.25 ... 2.5 mm2), 2x (0.25 ... 1.0 mm2)
● Type of connectable conductor cross-section /
at the digital outputs
— for AWG conductors / solid 1x 24 ... 12
— solid 1x (0.2 ... 2.5 mm2), 2x (0.2 ... 1.0 mm2)
— finely stranded / with core end processing 1x (0.25 ... 2.5 mm2), 2x (0.25 ... 1.0 mm2)
Type of electrical connection
Mechanical Design
Height mm 96
Height / of the display mm 54
Width mm 96
Width
● of the display mm 72
Depth mm 82
mounting position vertical
Installation depth mm 77
Installation depth / with expansion module / mm 99
maximum
Mounting type / panel mounting Yes
Material thickness / of the control panel
● maximum mm 4
Environmental conditions
Degree of pollution 2
Installation altitude / at height above sea level / m 2 000
maximum
Standard
● for EMC for industrial sector IEC 61000-6-2
● for EMC against unloading IEC 61000-4-2
● for EMC against high frequency fields IEC 61000-4-3
● for EMC against conducted LF disturbance IEC 61000-6-4
variables (industry)
● for EMC against conducted disturbance IEC 61000-4-6
variables via HF fields
● for EMC against magnetic fields with power IEC 61000-4-8
engineering frequencies
● for EMC against quick, transient electrical IEC 61000-4-4
disturbances
● for EMC against voltage drops and IEC 61000-4-11
interruptions
● for EMC against surge voltages IEC 61000-4-5
● for free fall IEC 60068-2-32
● for pulse emitter according to IEC62053-31
● for cyclic, environmental damp heat check IEC 60068-2-30
● for environmental coldness check IEC 60068-2-1
● for environmental dry heat check IEC 60068-2-2
Relative humidity / at 25 °C / without condensation /
during operation
● minimum % 5
● maximum % 95
Certificates
Certificate of suitability
● as EC declaration of conformity IEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-
1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with
"Berichtigung 1"
● as approval for Canada UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-
04
● as approval for USA UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-
04
● Approval Australia Yes
● Approval Russia Yes
Equipment marking / acc. to DIN EN 61346-2 P
other
PROFINET-
Zertifizierung
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://eb.automation.siemens.com/mall/en/WW/Catalog/Product/7KM42120BA002AA0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
http://support.automation.siemens.com/WW/view/en/7KM42120BA002AA0/all
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=7KM42120BA002AA0
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://ausschreibungstexte.siemens.com/tiplv
-X3
-X1
IL1/k IL1/l IL2/k IL2/l IL3/k IL3/l
SENTRON
POWER
PANEL
FOR
VAUX:
VIN:
AMPIN:
RING MAX.690/400V;
MEASUREMENT
LUG
110-340VDC
MOUNT
X/1A
MONITORING
TERMINALS
PAC4200;
ORTYPE
X/5A
/45-65HZ
95-240VAC
LCD;
AC
OF
DEVICE
ELECTR.
96X96MMVALUES