RRU5901 (1800Mhz) - Technical Specifications
RRU5901 (1800Mhz) - Technical Specifications
RRU5901 (1800Mhz) - Technical Specifications
RF Specifications
The following tables list RF specifications of an RRU5901.
NOTE:
• ATBR in the TX/RX Channel column indicates that the RF module uses A transmit
channels and B receive channels.
• The GSM receiver sensitivity, as recommended in 3GPP TS 51.021, is measured at the
antenna connector assuming that the channel rate is 13 kbit/s and the bit error rate (BER)
is lower than or equal to 2%.
• The LTE FDD receiver sensitivity, as recommended in 3GPP TS 36.104, is measured
under a 5 MHz channel bandwidth based on the FRC A1-3 in Annex A.1 (QPSK, R = 1/3,
25 RBs) standard.
• The LTE NB-IoT receiver sensitivity, as recommended in 3GPP TS 36.104, is measured
under a 200 kHz bandwidth and a 15 kHz subcarrier spacing based on the FRC A14-1 in
Annex A.14 (π/2 BPSK, R = 1/3, one RB) standard.
NOTE:
For details about power configuration principles for RF modules, see Power Configuration Principles for
RF Modules.
the same as their downlink bandwidth. For details about the downlink bandwidth, see "Typical Output
Power".
2 (MIMO) 1 15, 20
8 2 (MIMO) 1 15, 20
Engineering Specifications
The following tables list the equipment specifications of an RRU5901.
NOTE:
• DC RRUs can use external power modules (such as AC/DC power modules, OPM15M,
and OPM50M) to support AC scenarios. For details about the external power modules, see
user guides of the corresponding models.
• The typical power consumption of an RF module is measured when the ambient
temperature is 25°C and the traffic load reaches 50%. The actual power consumption has a
10% deviation from this value.
NOTE:
According to the installation scenario, traffic load, and carrier configuration, the output power of an
RRU decreases when the RRU reaches a temperature 10°C less than its maximum operating
temperature.
RF • 3GPP TS 45.005
• 3GPP TS 36.141
• 3GPP TS 38.104
• 3GPP TS 37.141
Ingress IP65
protection
rating
Item Standard
• IEC 62305-3 Protection against lightning - Part 3: Physical
damage to structures and life hazard
• IEC 62305-4 Protection against lightning - Part 4: Electrical and
electronic systems within structures
• ITU-T K.35 Bonding configurations and earthing at remote
electronic sites
• ITU-T K.56 Protection of radio base stations against lightning
discharges
• ITU-T K.97 Lightning protection of distributed base stations
• ETSI EN 300 253 Environmental Engineering (EE): Earthing
and bonding configuration inside telecommunications centers
• YD/T 2324-2011: Lightning protection requirements and test
methods for radio base stations
• GB 50689-2011: Code for design of lightning protection and
earthing engineering for telecommunication bureaus (stations)
The following table lists the surge protection specifications of ports on an RRU5901.
NOTE:
• Unless otherwise specified, the surge protection specifications depend on the surge
waveform of 8/20 μs.
• All the surge current items, unless otherwise specified as Maximum discharge current,
refer to Nominal discharge current.
Table 13 RRU5901 CPRI cascading levels and maximum distance from the BBU
Type Cascading Level Maximum Distance from the BBU (km)
Antenna Capability
The following table lists the antenna capability of an RRU5901.
NOTE:
For RF modules supporting RET antennas, the feeding voltage is 12 V and feeding current is 2.3 A.