Trilogy EV300 Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Trilogy EV300

Continuum of care.
Simplified workflow.
Introducing Trilogy EV300
Smooth patient transitions Proven performance in noninvasive
Transitions are part of the daily routine in hospital settings – particularly when it comes to respiratory care. But hospital and invasive ventilation
respiratory care teams are understaffed and overburdened, which can make patient transitions challenging and stressful.
The Trilogy EV300 ventilator delivers enhanced performance in noninvasive
Developed specifically for hospitals, the Philips Respironics Trilogy EV300 lets you move patients through different hospital (NIV) and invasive (IV) ventilation, so patients can be treated with a single device
departments while they remain on one device – reducing disruptions and providing continuous peace of mind. throughout their hospital stay, regardless of changing conditions. Comprehensive,
advanced NIV auto-titrating therapy modes include AVAPS-AE, and invasive

Simplified workflow ventilation is available with single- and dual-limb circuits and leak compensation.

Trilogy EV300 ventilators feature an easy-to-use 8-inch touchscreen and intuitive menu navigation. On-screen help and
alarm guidance aid user proficiency–making it easy for clinicians to rapidly feel confident. Elevating respiratory care
The Trilogy EV300 ventilator is designed to treat the varying needs of
respiratory insufficiency throughout the patient’s stay. The Trilogy EV300
advanced measurement system estimates lung compliance, airway resistance,
AutoPEEP and plateau pressure without requiring an inspiratory or expiratory
hold maneuver. AVAPS-AE – an auto-titration mode of noninvasive ventilation
with multiple algorithms that work simultaneously – meets the changing needs
of your patients. AVAPS automatically adjusts to breathing, while Auto EPAP
proactively adjusts to the lowest effective pressure for peak comfort. Auto Backup
delays a machine breath until the patient has exhaled, to reduce air trapping.

Enhancing patient comfort


Designed to make breathing more comfortable, Auto-Trak provides an
automated breath triggering and cycling algorithm that adjusts to the patient’s
natural breathing patterns and maintains exceptional performance in the
presence of leaks. It assists with ventilator-to-patient synchrony without manual
adjustments. With sensitive Auto-Trak, Trilogy EV300 can now deliver quality
therapy to smaller patients (2.5 kg and above). In addition, the EtCO2 mainstream
measurement allows for confirmation of artificial airway placement, as well as
for continuous ventilation monitoring. The continuity of monitoring can facilitate
proactive decision-making and assist with weaning patients off the ventilator.1

Extended battery life Long service Lower costs


Designed for portability and intervals In addition to reduced maintenance
durability, Trilogy EV300 has a 15- costs, keeping patients on one device
Trilogy EV300 has a four-year service
hour battery life* with an internal and for noninvasive and invasive ventilation
interval. Additionally, it can be field-
detachable battery. Additionally, the throughout their hospital stay may
serviced with standard service tools,
hot swappable detachable battery allow for additional cost savings by
making Trilogy EV300 both easy and
provides uninterrupted power – reducing the number of circuits and
affordable to maintain.
delivering maximum portability for filters used per patient.
transitions between therapies and
different areas within the hospital.
Advancing hospital respiratory care
Choose Trilogy EV300 to help provide smooth transitions
across your patients’ changing environments as their disease
improves or deteriorates, from admission to discharge

Simple
Easy-to-learn user interface,
configurable to the care environment

Portable
15 hours of battery life*
to enable on-the-go use

Adaptable
Stays with patients throughout the
hospital as their needs change

Reliable
Durable, rugged design to support
use throughout the hospital

Learn more at philips.com/philips.com/EV300

*Nominal run time per method in International Electrotechnical Commission (7.5 hour/battery).
Detachable battery charge time 0% to 80% is 2.5 hours, internal battery charge time 0% to 100% is 3.5 hours.

Reference: 1. Berkenbosch JW, Lam J, Burd RS, Tobias JD. Noninvasive monitoring of carbon dioxide during mechanical ventilation in older children: end-tidal versus
transcutaneous techniques. Anesth Analg. 2001;92(6):1427-1431.

Caution: Federal law restricts this device to sale by or


on the order of a physician.
©2019 Koninklijke Philips N.V. All rights reserved. Philips Respironics North America
Specifications are subject to change without notice. 1010 Murry Ridge Lane
Trademarks are the property of Koninklijke Philips N.V. Murrysville, PA 15668 USA
or their respective owners.
+1 724 387 4000
MCI 4109441 PN 1144926 800 345 6443 (toll free, US only)
452299153231/November www.philips.com/respironics

You might also like