Trilogy EV300 Brochure
Trilogy EV300 Brochure
Trilogy EV300 Brochure
Continuum of care.
Simplified workflow.
Introducing Trilogy EV300
Smooth patient transitions Proven performance in noninvasive
Transitions are part of the daily routine in hospital settings – particularly when it comes to respiratory care. But hospital and invasive ventilation
respiratory care teams are understaffed and overburdened, which can make patient transitions challenging and stressful.
The Trilogy EV300 ventilator delivers enhanced performance in noninvasive
Developed specifically for hospitals, the Philips Respironics Trilogy EV300 lets you move patients through different hospital (NIV) and invasive (IV) ventilation, so patients can be treated with a single device
departments while they remain on one device – reducing disruptions and providing continuous peace of mind. throughout their hospital stay, regardless of changing conditions. Comprehensive,
advanced NIV auto-titrating therapy modes include AVAPS-AE, and invasive
Simplified workflow ventilation is available with single- and dual-limb circuits and leak compensation.
Trilogy EV300 ventilators feature an easy-to-use 8-inch touchscreen and intuitive menu navigation. On-screen help and
alarm guidance aid user proficiency–making it easy for clinicians to rapidly feel confident. Elevating respiratory care
The Trilogy EV300 ventilator is designed to treat the varying needs of
respiratory insufficiency throughout the patient’s stay. The Trilogy EV300
advanced measurement system estimates lung compliance, airway resistance,
AutoPEEP and plateau pressure without requiring an inspiratory or expiratory
hold maneuver. AVAPS-AE – an auto-titration mode of noninvasive ventilation
with multiple algorithms that work simultaneously – meets the changing needs
of your patients. AVAPS automatically adjusts to breathing, while Auto EPAP
proactively adjusts to the lowest effective pressure for peak comfort. Auto Backup
delays a machine breath until the patient has exhaled, to reduce air trapping.
Simple
Easy-to-learn user interface,
configurable to the care environment
Portable
15 hours of battery life*
to enable on-the-go use
Adaptable
Stays with patients throughout the
hospital as their needs change
Reliable
Durable, rugged design to support
use throughout the hospital
*Nominal run time per method in International Electrotechnical Commission (7.5 hour/battery).
Detachable battery charge time 0% to 80% is 2.5 hours, internal battery charge time 0% to 100% is 3.5 hours.
Reference: 1. Berkenbosch JW, Lam J, Burd RS, Tobias JD. Noninvasive monitoring of carbon dioxide during mechanical ventilation in older children: end-tidal versus
transcutaneous techniques. Anesth Analg. 2001;92(6):1427-1431.