V430 J R34 Especificacao Tecnica

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

V130-33-R34/V130-J-R34

V350-35-R34/V350-J-R34
Vision™ OPLC™ V430-J-R34
Technical Specifications

Order Information
Item
V130-33-R34 PLC with Classic panel, Monochrome display 2.4"
V130-J-R34 PLC with Flat panel, Monochrome display 2.4"
V350-35-R34 PLC with Classic panel, Color touch display 3.5’’
V350-J-R34 PLC with Flat panel, Color touch display 3.5’’
V430-J-R34 PLC with Flat panel, Color touch display 4.3’’
You can find additional information, such as wiring diagrams, in the product’s installation guide
located in the Technical Library at www.unitronics.com.

Power Supply
V130-R34 V350-R34 V430J-R34
Item V130J-R34 V350J-R34
Input voltage 24VDC
Permissible range 20.4VDC to 28.8VDC with less than 10% ripple
Max. current
See Note 1
consumption
npn inputs 245mA@24VDC 275mA@24VDC 275mA@24VDC
pnp inputs 170mA@24VDC 200mA@24VDC 200mA@24VDC
Notes:
1. To calculate the actual power consumption, subtract the current for each unused element from the maximum
current consumption value according to the values below:
Backlight Ethernet Relay Outputs
card (per output)
V130/J 10mA 35mA 5mA
V350/J/V430J 20mA 35mA 5mA

Digital Inputs
Number of inputs 22. See note 2
Input type See note 2
Galvanic isolation None
Nominal input voltage 24VDC
Input Voltage
pnp (source) 0-5 VDC for Logic ‘0’
17-28.8 VDC for Logic ‘1’
npn (sink) 17-28.8 VDC for Logic ‘0’
0-5 VDC for Logic ‘1’
Input Current 3.7mA@24VDC
Input impedance 6.5KΩ
Response Time 10ms typical, when used as normal digital input
Input Cable length
Normal digital Input Up to 100 meters
High Speed Input Up to 50 meters, shielded, see Frequency table below

Unitronics 1
1/15 Vision™ OPLC™

High speed inputs Specifications below apply when wired as HSC/shaft-encoder.


See Note 2
Frequency (max) See Note 3
Cable length (max.) HSC Shaft-encoder pnp Shaft-encoder npn
10m 30kHz 20kHz 16kHz
25m 25kHz 12kHz 10kHz
50m 15kHz 7kHz 5kHz
Duty cycle 40-60%
Resolution 32-bit

Notes:
2. This model comprises a total of 22 inputs. Input functionality can be adapted as follows:
22 inputs may be used as digital inputs. They may be wired, in a group, and set to either
npn or pnp via a single jumper.
In addition, according to jumper settings and appropriate wiring:
- Inputs 14 and 15 can function as either digital or analog inputs.
- Inputs 0, 2, and 4 can function as high-speed counters, as part of a shaft-encoder,
or as normal digital inputs.
- Inputs 1, 3, and 5 can function as either counter reset, as part of a shaft-encoder,
or as normal digital inputs.
- If inputs 0, 2 and 4 are set as high-speed counters (without reset), inputs 1, 3 and 5
can function as normal digital inputs.
3. pnp/npn maximum frequency is at 24VDC.

Analog Inputs
Number of inputs 2, according to wiring as described above in Note 2
Input type Multi-range inputs: 0-10V, 0-20mA, 4-20mA
Input range 0-20mA, 4-20mA 0-10VDC
Input impedance 243Ω >150KΩ
Maximum input rating 25mA, 6V 15V
Galvanic isolation None
Conversion method Successive approximation
Resolution (except 4-20mA) 10-bit (1024 units)
Resolution (at 4-20mA) 204 to 1023 (820 units)
Conversion time One configured input is updated per scan. See Note 4
Precision 0.9%
Status indication Yes – if an analog input deviates above the permissible range, its value will be
1024.
Notes:
4. For example, if 2 inputs are configured as analog, it takes 2 scans to update all analog values.

2 Unitronics
Vxxx-R34 Technical Specifications 1/15

Relay Outputs
Number of outputs 12 relay (in 3 groups). See Note 5
Output type SPST-NO (Form A)
Galvanic isolation By relay
Type of relay Tyco PCN-124D3MHZ or compatible
Output current 3A maximum per output
(resistive load) 8A maximum total per common
Rated voltage 250VAC/30VDC
Minimum load 1mA, 5VDC
Life expectancy 100k operations at maximum load
Response time 10ms (typical)
Contact protection External precautions required (see Increasing Contact Life Span in the product’s
Installation Guide)
Notes:
5. Outputs 0, 1, 2, and 3 share a common signal.
Outputs 4, 5, 6, and 7 share a common signal.
Outputs 8, 9, 10, and 11 share a common signal.

Graphic Display Screen


V130-R34 V350-R34 V430J-R34
Item V130J-R34 V350J-R34
LCD Type STN, LCD display TFT, LCD display TFT, LCD display
Illumination backlight White LED White LED White LED
Display resolution 128x64 pixels 320x240 pixels 480x272 pixels
Viewing area 2.4" 3.5" 4.3"
Colors Monochrome 65,536 (16-bit) 65,536 (16-bit)
Screen Contrast Via software Fixed Fixed
(Store value to SI 7,
values range: 0 to 100%)
Touchscreen None Resistive, analog Resistive, analog
‘Touch’ indication None Via buzzer Via buzzer
Screen brightness control Via software Via software
(Store value to SI 9, (Store value to SI 9, values range: 0 to 100%)
0 = Off, 1 = On)
Virtual Keypad None Displays virtual keyboard when the application requires
data entry.

Keypad
V130-R34 V350-R34 V430J-R34
Item V130J-R34 V350J-R34
Number of keys 20 keys,including 10 5 programmable function keys
user-labeled keys
Key type Metal dome, sealed membrane switch
Slides Slides may be installed in Slides may be installed in None
the operating panel the operating panel
faceplate to custom-label faceplate to custom-label
the keys. Refer to V130 the keys. Refer to V350
Keypad Slides.pdf. Keypad Slides.pdf.
A complete set of blank Two sets of slides are
slides is available by supplied with the
separate order controller: one set of
arrow keys, and one
blank set.

Unitronics 3
1/15 Vision™ OPLC™

Program
V130-R34 V350-R34 V430J-R34
Item V130J-R34 V350J-R34
Memory size
Application Logic 512KB 512KB 512KB
Images 256KB 6MB 12MB
Fonts 128KB 1MB 1MB

Operand type Quantity Symbol Value


V130-R34 V350-R34
Item V130J-R34 V350J-R34
V430J-R34
Memory Bits 4096 8192 MB Bit (coil)
Memory Integers 2048 4096 MI 16-bit signed/unsigned
Long Integers 256 512 ML 32-bit signed/unsigned
Double Word 64 256 DW 32-bit unsigned
Memory Floats 24 64 MF 32-bit signed/unsigned
Fast Bits 1024 1024 XB Fast Bits (coil) – not retained
Fast Integers 512 512 XI 16 bit signed/unsigned
(fast, not retained)
Fast Long Integers 256 256 XL 32 bit signed/unsigned
(fast, not retained)
Fast Double Word 64 64 XDW 32 bit unsigned (fast, not retained)
Timers 192 384 T Res. 10 ms; max 99h, 59 min, 59.99s
Counters 24 32 C 32-bit

Data Tables 120K dynamic data (recipe parameters, datalogs, etc.)


192K fixed data (read-only data, ingredient names, etc)
Expandable via SD card. See Removable Memory below
HMI displays Up to 1024

Program scan time 20µs per 1kb 15µs per 1kb


of typical of typical
application application

Removable Memory
Micro SD card Compatible with standard SD and SDHC; up to 32GB store datalogs, Alarms,
Trends, Data Tables, backup Ladder, HMI, and OS.
See Note 6
Notes:
6. User must format via Unitronics SD tools utility.

4 Unitronics
Vxxx-R34 Technical Specifications 1/15

Communication Ports
Port 1 1 channel, RS232/RS485 and USB device (V430 only). See Note 7
Galvanic isolation No
Baud rate 300 to 115200 bps
RS232
Input voltage ±20VDC absolute maximum
Cable length 15m maximum (50’)
RS485
Input voltage -7 to +12VDC differential maximum
Cable type Shielded twisted pair, in compliance with EIA 485
Cable length 1200m maximum (4000’)
Nodes Up to 32
USB device (V430 only)
Port type Mini-B, See Note 9
Specification USB 2.0 complaint; full speed
Cable USB 2.0 complaint; up to 3m
Port 2 (optional) See Note 8
CANbus (optional) See Note 8

Notes:
7. This model is supplied with a serial port: RS232/RS485 (Port 1). The standard is set to either RS232 or RS485
according to jumper settings. Refer to the product’s Installation Guide.
8. The user may order and install one or both of the following modules:
- An additional port (Port 2). Available port types: RS232/RS485 isolated/non-isolated, Ethernet
- A CANbus port
Port module documentation is available on the Unitronics website.
9. Note that physically connecting a PC to the controller via USB suspends RS232/RS485 communications
via Port 1. When the PC is disconnected, RS232/RS485 resumes.

I/O Expansion
Additional I/Os may be added. Configurations vary according to module.
Supports digital, high-speed, analog, weight and temperature measurement I/Os.
Local Via I/O Expansion Port. Integrate up to 8 I/O Expansion Modules comprising up
to 128 additional I/Os. Adapter required (P.N. EX-A2X).
Remote Via CANbus port. Connect up to 60 adapters to a distance of 1000 meters from
controller; and up to 8 I/O expansion modules to each adapter (up to a total of
512 I/Os). Adapter required (P.N. EX-RC1).

Miscellaneous
Clock (RTC) Real-time clock functions (date and time)
Battery back-up 7 years typical at 25°C, battery back-up for RTC and system data, including
variable data
Battery replacement Yes. Coin-type 3V, lithium battery, CR2450

Unitronics 5
1/15 Vision™ OPLC™

Dimensions
V130-R34 V350-R34 V430J-R34
Item
V130J-R34 V350J-R34
Size Vxxx 109 x 114.1 x 68mm 109 x 114.1 x 68mm
(4.29 x 4.49 x 2.67”). (4.29 x 4.49 x 2.67”).
See Note 10 See Note 10
Vxxx-J 109 x 114.1 x 66mm 109 x 114.1 x 66mm 136 x 105.1 x 61.3mm
(4.92 x 4.49 x 2.59”). (4.92 x 4.49 x 2.59”). (5.35 x 4.13 x 2.41”).
See Note 10 See Note 10 See Note 10
Weight 227g (8 oz) 245g (8.64 oz) 275g (9.7 oz)

Notes:
10. For exact dimensions, refer to the product’s Installation Guide.

Environment
Operational temperature 0 to 50ºC (32 to 122ºF)
Storage temperature -20 to 60ºC (-4 to 140ºF)
Relative Humidity (RH) 10% to 95% (non-condensing)
Mounting method Panel mounted (IP65/66/NEMA4X)
DIN-rail mounted (IP20/NEMA1)
Operating Altitude 2000m (6562 ft)
Shock IEC 60068-2-27, 15G, 11ms duration
Vibration IEC 60068-2-6, 5Hz to 8.4Hz, 3.5mm constant amplitude,
8.4Hz to 150Hz, 1G acceleration.

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole
discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or
temporarily withdraw any of the forgoing from the market.
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of
merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in
this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising
out of or in connection with the use or performance of this information.
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other
third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them.
DOC13037-A6 01/15

6 Unitronics

You might also like