Nokia-Africell 5G
Nokia-Africell 5G
Nokia-Africell 5G
Disclaimer
Nokia recommends that users have relevant knowledge of 5G system equipment.
Note:
Only properly trained and authorized personnel should perform installation, commissioning, or
maintenance operations on any Nokia equipment.
The screenshots included should be considered as examples only. The current release of the software
might differ slightly from the screenshots depicted.
Confidential
5G BoM
Config 01 (HW)
5G Addition
3500MHz 64T64R
5G-SRAN TDD 3500 1/1/1
64T64R 80MHz
(200W) (8D_4UL)
Config_Site_Identifier
to be filled in by the Solution Manager
Code Description QTY
Baseband
473764A ASIB AirScale Common 1
475266A ABIO AirScale Capacity 1
Airscale RFM_RRH Units
475440A AEQI AirScale MAA 64T64R 192AE n78 200W 3
Radio Ancillaries/Installation
474283A APPC AirScale2 55A DC plug 10-16 mm2 3
475188A AMPF bracket 25 degree tilt 3
BTS Optional HW
471649A FPKA Flexi Pole Kit 2
CS7136001 FPFH Flexi Power Distribution Module 1
Fronthaul Cable and SFP
474900A AOMC SFP28 70m MM I-temp RS 6
475689A ATMM OM3 OD fiber LC ODv2-LC ID dual 70m 3
Backhaul
473471A FOTA Optical SFP+ 10GBase-SR 850nm MM 2
473305A FUFBC MM OD fiber LC OD-LC OD dual 10m 1
GPS-SRAN & 5G
474074A FYGC GNSS Receiver Antenna 1
472510A FTSE GPS cable assembly 30m 1
471605A FYMA GPS MOUNTING KIT 1
3 © 2022 Nokia 471812A FYEA GPS Surge Protector Kit 1
ASIB
4 © 2022 Nokia
ABIO Capacity unit front panel and external interfaces
ABIO 475266A: ABIO AirScale Capacity Unit – front panel view
5G 3-sectors
N78: [80MHz] 111@ 64Tx / 64Rx ATMM OM3
ABIA L2RT
LTE 3-sectors
L8: [15MHz] 111@ 2Tx / 2Rx ABIA
L18: [20MHz] 111@ 2Tx / 2Rx L2RT
L26: [10MHz] 111@ 2Tx / 2Rx ABIA ABIO AOMC SFP28
L2RT
WCDMA 3-sectors
W9: 111 @1Tx / 2Rx ASIB ASIB FYGC GNSS Receiver Antenna
W21: 444 1Tx / 2Rx FOTA SFP+
FUFBC
GSM 3-sectors
G9: 222 1Tx / 2Rx
G18: 444 1Tx / 2Rx AirScale subrack AMIA 10 GE TX
7 © 2022 Nokia
5G/LTE Network Configuration
GPS & Backhaul Connection details
FYEA
472577A FTSH GPS cable assembly 100m
8 © 2022 Nokia
gNB Commissioning & Integration
Confidential
Commissioning Process
Confidential
Pre-requisites
Laptop/PC with network adapter and Web browser compatible with WebEM is installed
SW to be installed:
5G21B SW package will be shared
Site cabling:
All cables are connected as per planning
Confidential
Setting up ASIB & Laptop/PC
Connect the ASIB’s LMP port to a laptop/PC LAN interface (peer to peer connection).
Set your PC IP to 192.168.255.126 netmask 255.255.255.0
Confidential
Install SW via BTS Rescue Console
Confidential
BTS RESCUE CONSOLE
Confidential
Login to BTS RESCUE CONSOLE
ASIB SW verification and installation
New ASIB modules are loaded with Factory Default Software (FDSW). Login to the rescue console
using local management IP https://192.168.255.129
Username: Nemuadmin
Password: nemuuser
Confidential
Enabling SSH
Confidential
Software tab view
Confidential
Locating the SW package file of the new software
Confidential
Selecting the type of installation
Confidential
Summary of installation
Confidential
Uploading software package in progress
Confidential
Software package installed successfully
Confidential
Waiting for system reboot
Confidential
Commissioning gNB via WebEM
Confidential
Web Element Manager (WebEM)
Confidential
Commissioning gNB via WebEM
• Login to the WebEM using local management IP https://192.168.255.129 after 5G21B SW
upgrade completed successfully. Username: Nemuadmin Password: nemuuser
Confidential
Commissioning gNB via WebEM
Confidential
Commissioning gNB via WebEM
Confidential
Validate and Activate Plan
Confidential
CPRI to eCPRI Migration : CPRI SCF Activated
Note : If AEQIs are already on eCPRI, they will not be detected with CPRI SCF
If fault 23 “Incompatible SW version detected” is raised, upload the software once again.
All the AEQIs that are on CPRI will be detected and fault 4687 “CPRI RU Migration to eCPRI Mode
Required” will be raised.
Confidential
CPRI to eCPRI Migration
Navigate to Parameter Editor = Configuration> Configuration Management> Parameter Editor
Confidential
CPRI to eCPRI Migration
Navigate to MNL object : Navigation Panel > Current BTS configuration > MRBTS-XXX > MNL-1
XXX = MRBTS ID
Confidential
CPRI to eCPRI Migration
Add the COMMAND [CMD-1] object if does not exist
-MRBTS-XXX/MNL-1/CMD-1
XXX = MRBTS ID
Y = Radio Module number
Confidential
CPRI to eCPRI Migration
Validate and Activate Plan
Upload the software once again when fault 23 Incompatible SW version detected is raised.
Confidential
Verify eCPRI on all RUs
Confidential
Verify gNB is On Air
Confidential
Confidential