Instructions for DKC500DCL/DKC800DCL
WARNING
☆ Instructions must be read before installation. Please follow these instructions carefully,
incorrect installation could affect gate operation.
☆ When mounting and positioning this product please ensure the power cable is
unplugged.
☆ The motor cover will need to be removed to mount the motor to the mounting plate or
directly to the concrete footing.
☆ Any changes to the settings on this product can only be made by a licensed electrician.
☆ This product can be powered by AC110V/220V power supply or backup battery power
and solar power.
www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
WARRANTY
1. To repair against this warranty card and invoice during the warranty period.
2. Warranty period: 1 year after the date of invoice.
3. Without unauthorized dismantling, any product broken or damage due to quality problem,
we’ll offer the repair service for free or replace for free.
4. The malfunction and damages caused by incorrect use or man fault is not covered by this
warranty.
CONTACT US
E-mail: [email protected]
Email Address
Issue Details
www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
CONTENTS
Default Setting Instruction..............................................................................................................1
Safety Instruction.............................................................................................................................2
Parts List...........................................................................................................................................3
Technical Parameters......................................................................................................................5
Installation........................................................................................................................................5
Before You Start..........................................................................................................................5
Tools Required / Example Sliding Gate………............................................................................6
Step 1 - Gate Preparation............................................................................................................6
Step 2 - Checking Manual Release.............................................................................................7
Step 3 - Removing / Installing Motor Cover.................................................................................7
Step 4 – Motor Pad Footing.........................................................................................................8
Step 5 - Fitting Mounting Base and Motor....................................................................................8
Step 6 - Sprocket and Chain & Motor Alignment.......................................................................10
Step 7 - Limit Switch Stops........................................................................................................11
Step 8 - Powering on........................……..................................................................................13
Step 9 - Testing Travel and Limit Stops.....................................................................................14
Programming and Wiring..............................................................................................................15
DIP Switch Adjustment..............................................................................................................16
Potentiometer Adjustment.........................................................................................................17
Terminal Instructions.................................................................................................................18
Wiring to the Terminal...............................................................................................................20
Connecting Infrared Photocells.................................................................................................21
Remote Control Operation........................................................................................................22
Connecting Storage Battery......................................................................................................22
Connecting Solar Panel.............................................................................................................22
Wiring to the Transformer..........................................................................................................23
Maintenance...................................................................................................................................23
Troubleshooting.............................................................................................................................24
Drawing and Measurements..........................................................................................................25
www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Press the first/top button Rotating output sprocket will Then the gate will move in
on the remote. drive the gate frame. the set direction.
Figure 2
Note: Ensure that the gate opener is unplugged before proceeding with installation. Please keep
fingers away from the motor output sprocket whilst it is turning.
If your gate needs to open from the other direction (to the left, refer to figure 3), your opener needs
to be mounted on the left-hand side as shown, the relative wires need to be swapped over, please
check under “Terminal Instructions” for swapping. (Factory default setting is for right-hand opening:
opener mounted on the right-hand side).
Figure 3
Any works done to the gate opener must be completed whilst the power is off, and the opener is
unplugged.
1 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Safety Instruction
Warning: Incorrect or improper use of this product can cause damage to persons, animals or
properties.
· Please ensure that the input voltage used matches with the supply voltage of gate opener.
· All modifications to wiring or electrics, and any adjustment or maintenance to input voltage
must be done by a qualified electrician.
· All potential hazards and exposed pinch points of the gate must be eliminated or guarded prior
to installation of this gate opener.
· Never mount any device that operates the gate opener where the user can reach over (under,
around or through) the gate to operate the controls. These must be placed away from any
moving range of the moving gate.
· Ensure power plug is disconnected from the power socket during installation or maintenance.
· Keep remote control and other control devices out of children’s reach, in order to avoid
unintentional activation.
· To ensure safety, before installing the motor, mount a Gate End Catch and a Gate Stop at each
end of the rail to prevent the gate travelling off the track.
· If required, install infrared photocell to detect obstructions and prevent injury to person or
damage to property.
· Instruct all users about the control systems provided and the manual opening operation in case
of emergency.
· Ensure that the power cable is connected to a RCD protected weatherproof power outlet
installed by a qualified electrician.
· Do not install this product in an explosive atmosphere or where there is any danger of flooding.
· This product was exclusively designed and manufactured for the use specified in the present
documentation. Any other use not specified in this documentation could damage the product
and be dangerous.
· Only use original parts for any maintenance or repair operation. Our company declines all
responsibility with respect to the automation safety and correct operation when other supplier’s
components are used.
· Do not modify the automation components, unless explicitly authorized by our company.
· The user must avoid any attempt to carry out any works or repairs on this product, and should
always request the assistance of qualified personnel.
· This product is suitable for use on one sliding gate only.
· Anything which is not expressly provided for in these instructions is not allowed and will void
warranty.
· Dispose of all packing materials (plastic, cardboard, polystyrene etc.) according to current
guidelines. Keep plastic bags and polystyrene out of children’s reach.
· Save these instructions for future use.
2 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Parts List
Parts List (standard configuration)
No. Picture Name Quantity
1 Motor 1
3 Remote Controls 2
3 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Magnets 2
4-10
Hexagon Head Bolt M6X65 4
Nut M8 4
Flat Washer φ8 2
Spring Washers φ8 2
Nut M6 16
4-13
Nut M8 16
Flat Washer φ6 16
4-14
Flat Washer φ8 16
Spring Washers φ6 16
4-15
Spring Washers φ8 12
Note: Extra flat washers and spring washers are spare parts.
1 Infrared Photocell 1
2 Wireless Keypad 1
3 Alarm Lamp 1
4 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Additional remote controls: Spare/Additional remotes for the automatic gate kit, these will need to
be paired to the motor.
Infrared photocell: Detects pedestrians, vehicles and objects that cross an infrared beam and
prevents the gate from closing.
Wireless keypad: Allows secure access through the gate used with a user set code.
Wired control: Allow users to control the opening and closing of the door through an external
push-button.
Alarm lamp: Alerts people near the gate and users that the gate is in operation.
Technical Parameters
Model DKC500DCL DKC800DCL
Power Supply 110VAC/60Hz; 220VAC/50Hz
Motor Power 150W 170W
Gate Moving Speed 13m/min 18m/min
Maximum Loading Weight 500KG 800KG
Remote Control Distance ≥30m
Remote Control Mode Single button mode / Three button mode
Limit Switch Magnetic limit switch
Working Noise ≤58dB
Working Duty S2, 20min
Recording of up Remote Controls 40
Remote Frequency 433.92 MHz
Working Temperature -20°C - +70°C
Package Weight 16.42KG 16.5KG
Installation
Before You Start
· DKC500DCL/DKC800DCL Sliding Gate Automation Kit is suitable for powering the opening
and closing motion of gates up to 600kg,800kg in weight, up to a length of 8m. (Standard kit
contains a 6m chain, if the gate length is over 5.5m, please consider to extend the length of the
chain.)
· Gate motion is achieved by the rotating output sprocket of the gate opener driving the chain
fitted to the moving gate.
· The gate opener requires you to press the remote control once to open, and once again to
close. This is a safety feature to ensure safe operation.
· The gate opener itself must be fitted within private property, never externally to a property’s
boundary.
Any works done to the gate opener must be completed whilst the power is off and the opener is
unplugged. Any modifications/alterations/works to AC power components must only be completed by
a licensed electrician.
5 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Tools Required
· Tape measure
· Level
· 12mm concrete drill and hammer (when uses expansion screws)
· Phillips head screwdriver
· Straight screwdriver
Gate Track and Track Wheels Gate End Catch Gate Guide Rollers Gate Stop
Figure 4
Please ensure that the gate opener power cable is not plugged in at any stage before Step 8.
The gate should slide smoothly by hand before attempting to install the gate opener.
Figure 5
6 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Turn 90°
To make the motor into manual mode, insert the key In manual mode, the sprocket can turn
and open the manual release bar till it rotates by 90°. freely and the gate can be operated by
hand.
Figure 6
Figure 7
Bolts
Sprocket Cover
Figure 8
7 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Please Note: the rubber grommet must be fitted back onto the motor cover once the
cover has been re-fitted/replaced onto the base of the motor.
Figure 9
Figure 10
8 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Nut
Spring Washer
Flat Washer
Flat Washer
Nut
Figure 11
Fitting Motor
· Fit motor and mounting base on the concrete footing.
· Ensure the motor output sprocket and chain are correctly aligned. Sprocket and chain should
be centered as much as possible.
· Take the motor away from mounting base.
· Leave a space of 30cm from the motor to end of the chain.
9 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Figure 12
Figure 13
10 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Sprocket
Chain
Figure 14
It is extremely dangerous that without or incorrect installation of the limit switch stops can cause
crash of gate, damage of internal structure of the motor, moreover, the gate may slide off the guide
rail.
Closed Position
· Position gate 150-200mm back from the gate end catch closed position. This will help in
making sure you do not slam the gate into the end stop/catch when setting the closed position
under power.
· Fit limit switch stop onto the top of chain at the point where it meets the magnetic limit switch on
the motor.
· Tighten locking screws of limit switch stop.
11 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Open Position
· Position gate 150-200mm back from the gate stop open position. This will help in making sure
you do not slam the gate into the end stop/catch when setting the open position under power.
· Fit limit switch stop onto the top of chain at the point where it meets the magnetic limit switch on
the motor.
· Tighten locking screws of limit switch stop.
Test the magnetic limit switch stops by moving the gate manually until you hear a click, making sure
contact is made with the magnetic limit switch on the motor.
12 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Open Position Limit Switch Stop Closed Position Limit Switch Stop
Motor
Magnet
Gate
To Reset: Turning the power off will reset the limit switch stop memory. Power on the gate
opener again, pressing remote control or external push button switch to open and then
close the gate once, then new limit switch stop setting is completed.
Step 8 - Powering on
· Ensure that the outer cover has been fitted and fastened back onto the motor base.
· Before powering up the gate opener make sure the gate can travel by hand in manual mode
(key unlocked).
· Slide the gate to between the middle of the posts, approximately (see below diagrams).
· Lock the manual release spanner (key locked) in readiness for automatic mode.
· Plug the power cord into an approved RCD protected weatherproof outlet.
· Remote controls included in this kit are factory paired ready for use.
Figure 15
13 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
To Reset:
When setting new limit stop positions please ensure that you turn the power off and then on
again. Turning the power off will reset the limit stop memory, allowing for new limit switch
stop positions to be recognized by the motor.
Now the basic open and closed positions are set, for further setting functions and adjusting
parameters, please refer to pages 15-23 in this manual.
14 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Learn Button
J8 Terminal
J1 Terminal
J7 Terminal
24VAC
Storage Battery
Fuse
(10A 250V fuse)
Figure 16
15 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Figure 17
16 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
ON–enable
OFF–disable
7 Auto-reverse Function Default position is ON, this should align with the
opener status and is not recommended to be
modified by the users.
ON–enable
Photocell Delay OFF–disable
8
Detection Please enable this function if your motor is
connected with a photocell
Potentiometer Adjustment
All changes to these settings must be completed by a licensed electrician
Figure 18
17 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
J1 Terminal:
Terminal 5: Common Terminal for Photocell
Terminal 6: Photocell Input (N.C.). If no photocell is fitted, use
a jumper between terminals 5 & 6.
Terminal 7: Additional Accessories +24VDC
Additional accessories sold separately
J4 Terminal:
Motor Wire(above terminal connect to red motor wire, below
terminal connect to black motor wire)
Note: If require to change the moving direction, 1 simple way is to change the DIP 5,
another way is changing the wires, to do so, not only MOT1 and MOT2 wires need to
be swapped,but also the wires of OP and CL on J10 Terminal have to be swapped
with each other.
18 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Using a screwdriver to Insert the wire into the Tighten with a screwdriver
loosen the screw on the number on the terminal that to secure the wire in place.
side of the terminal. you are looking to connect to.
Refer to Page 15.
J10 Terminal:
OP: Open Limit Switch.
COM: Limit Switch Common Terminal.
CL: Close Limit Switch.
19 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and reverse
immediately, to protect user and property security. To install photocells, connect wiring as
per Figure 19. You must remove the wire jumper between terminal 5 and terminal 6 on J1
(ref to Figure 20).
The distance between photocell receiver and photocell transmitter should not be less than 2
meters; otherwise, the induction effect of photocell may be affected.
Photocell Photocell
Receiver Transmitter
3 core 2 core
cable cable
Figure 19
Before Installing Photocells
20 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Close
Stop
Pedestrian Pedestrian
Close Mode Mode
Three Button Mode Remote Control Single Button Mode Remote Control
Figure 21
21 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
C3
POWER
J2
D6
C23
F1
BAT+
DKC500DC.PCB
R8 R9
2015.01.05
Control board
-
+
- Storage battery
+
Figure 22
Storage battery
-
+
+ - + - + -
-
+
C3
POWER
J2
D6
C23
F1
BAT+
DKC500DC.PCB
2015.01.05 R8 R9
Control board
Figure 23
22 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
C3
POWER
J2
D6
C23
F1
BAT+
DKC500DC.PCB
2015.01.05 R8 R9
Figure 24
Maintenance
The gate should be checked every month to make sure it operates normally.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and
regular inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
Our company keep the right to change the instruction without prior notice.
23 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Troubleshooting
Any troubleshooting work below done to the motor must be completed by a licensed
electrician and only whilst the power is off and the motor is unplugged!
24 www.gatexpertstore.com
Instructions for DKC500DCL/DKC800DCL
Figure 25
25 www.gatexpertstore.com