CAUTION
Before serving the chassis, read the "X-Ray Radiation Precaution", "Safety Precaution" and "Product Safety
Notice" on page 2 of this manual.
X-RAY RADIATION PRECAUTION
1. Excessive high voltage can produce potentially hazardous X-Ray Radiation. To avoid such hazards, the high
voltage must not be above the specified limit. The normal value of the high voltage of this receiver is 24KV at zero
beam current (minimum brightness) under 220V AC power source. The high voltage must not, under any
circumstances, exceed 29KV.
2. Each time a receiver requires servicing, the high voltage should be checked following the High Voltage Check
procedure in this manual. It is recommended the reading of the high voltage be recorded as a part of the service
record. It is important to use an accurate and reliable high voltage meter.
3. The primary source of X-Ray Radiation in this TV Receiver is the picture tube. For continued X-Ray Radiation
protection, the replacement tube must be exactly the same type tube as specified in the part list.
4. Some parts in this receiver have special safety – related characteristics for X-Ray Radiation protection. For
continued safety, parts replacement should be undertaken only after referring to the Product Safety Notice.
SAFETY PRECAUTION
Warning: Service should not be attempted by anyone unfamiliar with necessary precaution on this receiver. The
following are the necessary precautions observed before servicing this chassis.
1. Since the power supply circuit of this receiver is directly connected to the AC power line, an isolation transformer
should be used during any dynamic service to avoid possible shock hazard.
2. Always discharge the picture tube anode to the CRT conductive coating before handling the picture tube. The
picture tube is highly evacuated and if broken, glass fragment will be violently expelled. Use shatter proof goggles
and keep picture tube away from the unprotected body while handling.
3. When replacing a chassis in the cabinet, always be certain that all the protective devices are put back in place,
such as: non-metallic control knobs, insulating covers, shields, isolation resistor-capacitor network etc.
4. When replacing parts or circuit boards, disconnect the power cord.
5. When replacing a high wattage resistor (Metal oxide film resistor) on circuit board, keep the resistor 10mm (1/2in.)
away from circuit board.
6. Connection wires must be kept away from components with high voltage or high temperature.
7. If any fuse in this TV receiver is blown, replace it with the FUSE specified in the chassis part list.
8. The receiver is designed to operate with 220V(50/60Hz) AC mains.
Before replacing any of these components, read the part list in this manual carefully. The use of substitute
replacement parts, which do not have the same safety characteristics, as specified in the part list may create shock,
fire, and X-Ray Radiation or other hazards.
2
CHASSIS ADJUSTMENT
1. B+ voltage adjustment (For 3N and 4N chassis only)
1-1 Connect 220V AC 50Hz to CN601 and switch on power switch SW601;
1-2 Test the voltage with digital voltage meter between two terminals of C625;
1-3 Adjust VR601 to obtain +110V+/-0.5V reading on the digital voltage meter.
Note: The 5N chassis is auto B+ voltage by SE130 or SE140 used.
2. NTSC system absorbing adjustment
2-1 Set sweep generator marker to 31.5MHz, 33.5MHz, 34.42MHz, 37MHz, 38MHz and 40.5MHz;
2-2 Apply 80dBuV sweep signal to tuner IF terminal;
2-3 Display demodulation probe connects to pre-I.F AMP input terminal, via. Q101 'b' pole;
2-4 Set Q103 'c' pole and 'e' pole short circuit, adjust L104, and make the attenuation most at 33.5MHz.
7. Sub-bright adjustment
7-1 Receive PHILIPS signal;
7-2 Set picture "Mild" mode.
7-3 Press 'factory' key one time and go to system parameter adjustment menu;
7-4 Press digital key '0', select 'SUB-BRIGHT';
7-5 Press 'VOL+' key and 'VOL-' key until Grey scale signal can be secerned;
7-6 Exit system parameter adjustment menu by pressing 'factory' key twin.
8. RF AGC adjustment
8-1 Receive 60dBuV monoscope pattern;
8-2 Press 'factory' key one time and go to system parameter adjustment menu;
8-3 Press 'PROG+' key and 'PROG-' key , select ' RF AGC ';
8-4 Press 'VOL+' key and 'VOL-' key to change the value of 'RF AGC' until picture's noise disturbing
disappears just;
4
8-5 Exit system parameter adjustment menu by pressing 'factory' key twin.
NOTES:
1. Connect the remote IC PIN7 and PIN16 through a jiggle switch on the USER remote handset , this switch is
defined as "screen" key; Connect the remote IC PIN8 and PIN16 through a jiggle switch on the USER remote
handset , this switch is defined as "factory" key,
2. On the product line's alignment service we must use special memorizer that has been well written data.
3. If having no special memorizer that has been well written data when servicing out of factory, we can use blank new
EEPROM. EEPROM will be automatically totally initialized after main power switch is on. Most parameters are
free-alignment after initialized; only need adjust the several parameters of function set parameter and system
parameter adjustment menu.
4. If no blank new EEPROM or no special memorizer that has been well written data, we can use memorizer that has
been written data instead, but must be totally initialized; the operation is as following:
1. After TV is on, press "factory" key twin then go to the function set menu;
2. Press 'AV/TV' key and 'MENU' key on the control board at the same time until the picture changes
slightly (jumpiness or twinkling at one blow); this means the memory having been totally initialized.
Operate repeatedly if the picture has no change;
3. Switch off and exit;
4. After initialized, adjust the several parameters of function set parameter and system parameter
adjustment menu.
5. the parameters of function set parameter and system parameter adjustment menu mustn't be adjusted;
1. system parameter adjustment menu (This is coming from the NN5198/ NN5199)
AFT
VIF VCO
H VCO
VIFDET NEG
VIFDET INT
VIFDET EXT
2. the ninth digital and the tenth digital of function set parameter
These parameters must be IC interior values. If the above parameters have been changed, we must
partially initialize the EEPROM.
5
6. two different initializing
1. fully initialize: initialize the EEPROM's most work data and preset default value. Including: work
parameter of NN5199, horizontal and vertical parameter, OPTION parameter (via. function set
parameter), picture mode parameter, volume mode parameter and white balance parameter.
2. partially initialize: only initialize work parameter of NN5199 and the ninth digital and the tenth digital of
function set parameter(via. ISUD0, ISUD1,ISUD3,ISUD4,ISUD5),preset as interior values.
7. If use 21” Pure Flat tube , must adjust horizontal size and pincushion distortion as following:
1. Receive monoscope pattern; Adjust VR902 until overscan ratio (scanning size)to 92% to 96%
2. Receive cross hatch pattern signal; Adjust VR901 until the pinchusion of the CRT two sides are most
straight.
8. If use 25” or above Pure Flat tube , must adjust horizontal size and pincushion distortion as following:
1. Receive 60dBuV PAL system monoscope pattern;
2. Press 'factory' key one time and go to system parameter adjustment menu;
3. Press 'MENU' key and select ' Position Menu ' as below
V POSITION for adjust vertical position 00 to 07
H POSITION for adjust Horizontal position 00 to 1F
V EHT for adjust vertical shape 00 to 0F
H EHT for adjust Horizontal shape 00 to 0F
4. Press 'MENU' key and select ' geometry Menu ' as below;
V-AMP for adjust vertical size 00 to 7F .
V_LINE for adjust vertical linearity 00 to 3F.
V_SC3 for adjust vertical S-correction X 3 00 to 3F.
H-AMP for adjust Horizontal size 00 to 3F.
EW-PARA for adjust Pincushion 00 to 3F.
EW-COR for adjust Pincushion corner 00 to 0F.
TRAPEZ for adjust trapezium 00 to 3F.
V_SC5 for adjust vertical S-correction X 5 00 to 0F.
5. Receive 60dBuV NTSC system monoscope pattern;
5.1 Repeat the above step 7.2 to 7.4.
6. Exit system parameter adjustment menu by pressing 'factory' key twin.
9. Option Code
1. Press 'factory' key twin and go to Option Code Menu
123456789A
13714046**
The first digit 8 Digit is set by Factory. The last two digit “9” and “A” is the random data from NN5198/NN5199.
Option digit 1:
Binary Dec Function Default
000 0 SECAM L OFF, SECAM OFF, NTSC OFF Default 7
001 1 SECAM L OFF, SECAM OFF, NTSC ON
6
010 2 SECAM L OFF, SECAM ON, NTSC OFF
011 3 SECAM L OFF, SECAM ON, NTSC ON
100 4 SECAM L ON, SECAM OFF, NTSC OFF
101 5 SECAM L ON, SECAM OFF, NTSC ON
110 6 SECAM L ON, SECAM ON, NTSC OFF
111 7 SECAM L ON, SECAM ON, NTSC ON
Option digit 2:
Binary Dec Function Default
000 0 RGB Beam limit ON, Woofer OFF, Sharp increase at 3MHz Default 3
001 1 RGB Beam limit ON, Woofer OFF, Sharp increase at 4MHz
010 2 RGB Beam limit ON, Woofer ON, Sharp increase at 3MHz
011 3 RGB Beam limit ON, Woofer ON, Sharp increase at 4MHz
100 4 RGB Beam limit OFF, Woofer OFF, Sharp increase at 3MHz
101 5 RGB Beam limit OFF, Woofer OFF, Sharp increase at 4MHz
110 6 RGB Beam limit OFF, Woofer ON, Sharp increase at 3MHz
111 7 RGB Beam limit OFF, Woofer ON, Sharp increase at 4MHz
Option digit 3:
Binary Dec Function Default
000 0 System BG OFF, System I OFF, System M OFF. Default 7
001 1 System BG OFF, System I OFF, System M ON.
010 2 System BG OFF, System I ON, System M OFF.
011 3 System BG OFF, System I ON, System M ON.
100 4 System BG ON, System I OFF, System M OFF.
101 5 System BG ON, System I OFF, System M ON.
110 6 System BG ON, System I ON, System M OFF.
111 7 System BG ON, System I ON, System M ON.
Option digit 4:
Binary Dec Function Default
000 0 Only AV1 No Default
001 1 AV1 +AV2
010 2 Only AV1
011 3 AV1 + AV2 + AV3
100 4 AV1 + S-VHS
101 5 AV1 + AV2 + S-VHS
110 6 AV1 + S-VHS
111 7 AV1 + AV2 + AV3 + S-VHS
Option digit 5:
Binary Dec Function Default
000 0 R/B gain =0.56, GAMMA ON , SKYWORTH game OFF Default 4
001 1 R/B gain =0.56, GAMMA ON , SKYWORTH game ON
010 2 R/B gain =0.56, GAMMA OFF , SKYWORTH game OFF
011 3 R/B gain =0.56, GAMMA OFF , SKYWORTH game ON
100 4 R/B gain =0.83, GAMMA ON , SKYWORTH game OFF
101 5 R/B gain =0.83, GAMMA ON , SKYWORTH game ON
110 6 R/B gain =0.83, GAMMA OFF , SKYWORTH game OFF
111 7 R/B gain =0.83, GAMMA OFF , SKYWORTH game ON
7
Option digit 6:
Binary Dec Function Default
000 0 PIF = 38.0MHz , No Signal Auto OFF, Normal gain Tuner Default 0
001 1 PIF = 38.0MHz , No Signal Auto OFF, High gain Tuner
010 2 PIF = 38.0MHz , No Signal no Auto OFF, Normal gain Tuner
011 3 PIF = 38.0MHz , No Signal no Auto OFF, High gain Tuner
100 4 PIF = 38.9MHz , No Signal Auto OFF, Normal gain Tuner
101 5 PIF = 38.9MHz , No Signal Auto OFF, High gain Tuner
110 6 PIF = 38.9MHz , No Signal no Auto OFF, Normal gain Tuner
111 7 PIF = 38.9MHz , No Signal no Auto OFF, High gain Tuner
Option digit 7:
Binary Dec Function Default
000 0 External SIF, QSS ON, Menu line ON Default 4
001 1 External SIF, QSS ON, Menu line OFF
010 2 External SIF, QSS OFF, Menu line ON
011 3 External SIF, QSS OFF, Menu line OFF
100 4 Internal SIF, QSS ON, Menu line ON
101 5 Internal SIF, QSS ON, Menu line OFF
110 6 Internal SIF, QSS OFF, Menu line ON
111 7 Internal SIF, QSS OFF, Menu line OFF
Option digit 8:
Binary Dec Function Default
000 0 SKYWORTH picture OFF, No Blue Background, English OSD only Default 0
001 1 SKYWORTH picture OFF, No Blue Background, English / Chinese OSD
010 2 SKYWORTH picture ON, English OSD only
011 3 SKYWORTH picture ON, English / Chinese OSD
100 4 SKYWORTH picture OFF, No Blue Background, English OSD only
101 5 SKYWORTH picture OFF, No Blue Background, English / Chinese OSD
110 6 Customer LOGO ON or Blue Background, English OSD only
111 7 Customer LOGO ON or Blue Background, English / Chinese OSD
9. Customer LOGO
The TV set art allow to display the Customer LOGO from 1 to 9 digit Character during Power on or No signal.
There is two method to set the Customer LOGO on.
9.1 Go to the function set menu (there are two ways;)
a. Press CH+(PROG+) key and CH-(PROG-) key on the control board at the same time and switch on
power switch, then go to the function set menu.
b. After TV is on, press "factory" key (See Note 1) twin then go to the function set menu.
9.1.1 Press the AV button to toggle between LOGO and Option Code
9.1.2 Press the below button for the difference function:
Recall : for the SKYWORTH LOGO display
Timer : for quick Blue background display.
Number 0 to 9: For no. of Character LOGO display.
Program + /- : Select the LOGO Character for modify.
Volume +/- : Change of LOGO Character.
S.M. : Change the Blue Background mode or transparence mode.
P.M. : Change of the Character Color.
8
9.1.3 Press the AV button to toggle to the Option Code mode and press the “Factory” key twin to exit.
9.2 Direct write the data to the EEPROM address.
Address
$199h No. of Character 00 to 09
$19C - $1A4h Display Character Refer table
$19Ah Character Color Refer table
9
5. Remove the DY wedges and slightly tilt the deflection yoke horizontally and vertically to obtain the
good overall convergence.
6. Fix the deflection yoke by wedges.
Magnet Clamper
Static Magnet
(FIG.1)
10