This document compares parameter values between a drive (Servo inverter 9300/2102IB) and its module. Most parameters are different between the drive and module, including status values, temperatures, firmware versions, and configuration settings. The drive shows an active trip fault while the module does not. Parameter values are also compared between the drive's 2 parameter sets, and a few values differ between sets.
This document compares parameter values between a drive (Servo inverter 9300/2102IB) and its module. Most parameters are different between the drive and module, including status values, temperatures, firmware versions, and configuration settings. The drive shows an active trip fault while the module does not. Parameter values are also compared between the drive's 2 parameter sets, and a few values differ between sets.
This document compares parameter values between a drive (Servo inverter 9300/2102IB) and its module. Most parameters are different between the drive and module, including status values, temperatures, firmware versions, and configuration settings. The drive shows an active trip fault while the module does not. Parameter values are also compared between the drive's 2 parameter sets, and a few values differ between sets.
This document compares parameter values between a drive (Servo inverter 9300/2102IB) and its module. Most parameters are different between the drive and module, including status values, temperatures, firmware versions, and configuration settings. The drive shows an active trip fault while the module does not. Parameter values are also compared between the drive's 2 parameter sets, and a few values differ between sets.
0040/000 Ctrl enable (write: control / read: status)
Ctrl inhibit / Ctrl enable 0042/000 DIS: Quickstop status QSP active / QSP inactive 0043/000 Trip status / reset Trip active / no TRIP / TRIP reset 0046/000 DIS: NSET-N -0.06 % / 0.00 % 0049/000 DIS: NSET-NADD -0.10 % / 0.00 % 0053/000 DIS: DC bus voltage (MCTRL_DCVOLT) 523 V / 0 V 0057/000 DIS: max torque calculated (C86/C22) 2.4 Nm / 0.0 Nm 0059/000 DIS: motor no. of pole pairs (calc.) 2 pairs / 1 pairs 0060/000 DIS: current rotor position 483 ° / 0 ° 0061/000 DIS: heatsink temperature 25 °C / 0 °C 0063/000 DIS: motor temperature 414 °C / 0 °C 0067/000 DIS: current TRIP Trip (EEr) External Trip set / OK 0068/000 Operating state C209h / 0000h 0086/000 Selection of motor type COMMON / MDSKS56-23-150 Servo-S Y, 0,6 kW, 150 Hz 0093/000 DIS: Drive ident 9324 Servo inverter / --- 0099/000 DIS: firmware version 8.0 / 1.0 0135/000 DCTRL control word 0200h hex / 0000h hex 0136/001 DIS: C0135 control word 0200h hex / 0000h hex 0150/000 DIS: DCTRL status word 08F2h hex / 0000h hex 0155/000 DIS: DCTRL status word 2 0069h hex / 0000h hex 0157/004 DIS: DCTRL status word STAT.B4 1 / 0 0157/005 DIS: DCTRL status word STAT.B5 1 / 0 0161/000 DIS: act. fault (Trip) Trip (EEr) External Trip set / OK 0168/001 DIS: active fault 1 Trip (EEr) External Trip set / OK 0169/001 DIS: active fault time 1 381951359 s / 0 s 0170/001 DIS: active fault quantity 1 1 / 0 0178/000 DIS: operation timer 173178485 s / 0 s ------------------------------------------------------------------------------ | Lenze Antriebstechnik |26.12.2023|11:26|-002-| ------------------------------------------------------------------------------
Load parameter set 2 / Load parameter set 1 0040/000 Ctrl enable (write: control / read: status) Ctrl inhibit / Ctrl enable 0042/000 DIS: Quickstop status QSP active / QSP inactive 0043/000 Trip status / reset Trip active / no TRIP / TRIP reset 0046/000 DIS: NSET-N -0.11 % / 0.00 % 0049/000 DIS: NSET-NADD -0.10 % / 0.00 % ------------------------------------------------------------------------------ | Lenze Antriebstechnik |26.12.2023|11:26|-004-| ------------------------------------------------------------------------------
0053/000 DIS: DC bus voltage (MCTRL_DCVOLT)
526 V / 0 V 0057/000 DIS: max torque calculated (C86/C22) 2.4 Nm / 0.0 Nm 0059/000 DIS: motor no. of pole pairs (calc.) 2 pairs / 1 pairs 0060/000 DIS: current rotor position 483 ° / 0 ° 0061/000 DIS: heatsink temperature 25 °C / 0 °C 0063/000 DIS: motor temperature 414 °C / 0 °C 0067/000 DIS: current TRIP Trip (EEr) External Trip set / OK 0068/000 Operating state C209h / 0000h 0086/000 Selection of motor type COMMON / MDSKS56-23-150 Servo-S Y, 0,6 kW, 150 Hz 0093/000 DIS: Drive ident 9324 Servo inverter / --- 0099/000 DIS: firmware version 8.0 / 1.0 0135/000 DCTRL control word 0200h hex / 0000h hex 0136/001 DIS: C0135 control word 0200h hex / 0000h hex 0150/000 DIS: DCTRL status word 08F3h hex / 0000h hex 0155/000 DIS: DCTRL status word 2 0069h hex / 0000h hex 0157/001 DIS: DCTRL status word STAT.B0 1 / 0 0157/004 DIS: DCTRL status word STAT.B4 1 / 0 0157/005 DIS: DCTRL status word STAT.B5 1 / 0 0161/000 DIS: act. fault (Trip) Trip (EEr) External Trip set / OK 0168/001 DIS: active fault 1 Trip (EEr) External Trip set / OK 0169/001 DIS: active fault time 1 381951359 s / 0 s 0170/001 DIS: active fault quantity 1 1 / 0 0178/000 DIS: operation timer 173178485 s / 0 s 0179/000 DIS: mains on timer 381954641 s / 0 s 0183/000 DIS: diagnostics Trip/fault / OK 0200/000 DIS: software ID 33S9300M_80000 / 0201/000 DIS: software date Jun 9 2008 09:06:10 / 0202/000 DIS: internal ID 8.000 / 0.000 0203/000 DIS: device Komm.-No. 000002110927 / 0204/000 DIS: device serial-No. 30 / 0 0206/000 DIS: device production date 09/22/08 / 0207/000 DIS: download info 1 / 0208/000 DIS: download info 2 / ------------------------------------------------------------------------------ | Lenze Antriebstechnik |26.12.2023|11:26|-005-| ------------------------------------------------------------------------------
Load parameter set 3 / Load parameter set 1 0040/000 Ctrl enable (write: control / read: status) Ctrl inhibit / Ctrl enable 0042/000 DIS: Quickstop status QSP active / QSP inactive 0043/000 Trip status / reset Trip active / no TRIP / TRIP reset 0046/000 DIS: NSET-N -0.06 % / 0.00 % 0049/000 DIS: NSET-NADD -0.10 % / 0.00 % 0053/000 DIS: DC bus voltage (MCTRL_DCVOLT) 524 V / 0 V 0057/000 DIS: max torque calculated (C86/C22) 2.4 Nm / 0.0 Nm 0059/000 DIS: motor no. of pole pairs (calc.) 2 pairs / 1 pairs 0060/000 DIS: current rotor position 483 ° / 0 ° 0061/000 DIS: heatsink temperature 25 °C / 0 °C 0063/000 DIS: motor temperature 414 °C / 0 °C 0067/000 DIS: current TRIP Trip (EEr) External Trip set / OK 0068/000 Operating state C209h / 0000h 0086/000 Selection of motor type COMMON / MDSKS56-23-150 Servo-S Y, 0,6 kW, 150 Hz 0093/000 DIS: Drive ident 9324 Servo inverter / --- ------------------------------------------------------------------------------ | Lenze Antriebstechnik |26.12.2023|11:26|-007-| ------------------------------------------------------------------------------
0099/000 DIS: firmware version
8.0 / 1.0 0135/000 DCTRL control word 0200h hex / 0000h hex 0136/001 DIS: C0135 control word 0200h hex / 0000h hex 0150/000 DIS: DCTRL status word 08F2h hex / 0000h hex 0155/000 DIS: DCTRL status word 2 0069h hex / 0000h hex 0157/004 DIS: DCTRL status word STAT.B4 1 / 0 0157/005 DIS: DCTRL status word STAT.B5 1 / 0 0161/000 DIS: act. fault (Trip) Trip (EEr) External Trip set / OK 0168/001 DIS: active fault 1 Trip (EEr) External Trip set / OK 0169/001 DIS: active fault time 1 381951359 s / 0 s 0170/001 DIS: active fault quantity 1 1 / 0 0178/000 DIS: operation timer 173178485 s / 0 s 0179/000 DIS: mains on timer 381954742 s / 0 s 0183/000 DIS: diagnostics Trip/fault / OK 0200/000 DIS: software ID 33S9300M_80000 / 0201/000 DIS: software date Jun 9 2008 09:06:10 / 0202/000 DIS: internal ID 8.000 / 0.000 0203/000 DIS: device Komm.-No. 000002110927 / 0204/000 DIS: device serial-No. 30 / 0 0206/000 DIS: device production date 09/22/08 / 0207/000 DIS: download info 1 / 0208/000 DIS: download info 2 / 0209/000 DIS: download info 3 / 0294/000 SSC Vp frequency controller 0.0 / 10.0 0355/001 DIS: Identifier CAN-IN1 513 / 0 0355/002 DIS: Identifier CAN-OUT1 385 / 0 0355/003 DIS: Identifier CAN-IN2 641 / 0 0355/004 DIS: Identifier CAN-OUT2 642 / 0 0355/005 DIS: Identifier CAN-IN3 769 / 0 0355/006 DIS: Identifier CAN-OUT3 770 / 0 0359/000 DIS: CAN state Pre-Operational / Operational 0400/000 DIS: AIN1-OUT -0.11 % / 0.00 % 0404/002 DIS: AIN1-GAIN 100.00 % / 0.00 % ------------------------------------------------------------------------------ | Lenze Antriebstechnik |26.12.2023|11:26|-008-| ------------------------------------------------------------------------------
Load parameter set 4 / Load parameter set 1 0040/000 Ctrl enable (write: control / read: status) Ctrl inhibit / Ctrl enable 0042/000 DIS: Quickstop status QSP active / QSP inactive 0043/000 Trip status / reset Trip active / no TRIP / TRIP reset 0046/000 DIS: NSET-N -0.06 % / 0.00 % 0049/000 DIS: NSET-NADD -0.10 % / 0.00 % 0053/000 DIS: DC bus voltage (MCTRL_DCVOLT) 520 V / 0 V 0057/000 DIS: max torque calculated (C86/C22) 2.4 Nm / 0.0 Nm 0059/000 DIS: motor no. of pole pairs (calc.) 2 pairs / 1 pairs 0060/000 DIS: current rotor position 483 ° / 0 ° 0061/000 DIS: heatsink temperature 25 °C / 0 °C 0063/000 DIS: motor temperature 414 °C / 0 °C 0067/000 DIS: current TRIP Trip (EEr) External Trip set / OK 0068/000 Operating state C209h / 0000h 0086/000 Selection of motor type COMMON / MDSKS56-23-150 Servo-S Y, 0,6 kW, 150 Hz 0093/000 DIS: Drive ident 9324 Servo inverter / --- 0099/000 DIS: firmware version 8.0 / 1.0 0135/000 DCTRL control word 0200h hex / 0000h hex 0136/001 DIS: C0135 control word 0200h hex / 0000h hex 0150/000 DIS: DCTRL status word 08F3h hex / 0000h hex 0155/000 DIS: DCTRL status word 2 0069h hex / 0000h hex 0157/001 DIS: DCTRL status word STAT.B0 1 / 0 0157/004 DIS: DCTRL status word STAT.B4 1 / 0 0157/005 DIS: DCTRL status word STAT.B5 1 / 0 0161/000 DIS: act. fault (Trip) Trip (EEr) External Trip set / OK 0168/001 DIS: active fault 1 Trip (EEr) External Trip set / OK 0169/001 DIS: active fault time 1 381951359 s / 0 s ------------------------------------------------------------------------------ | Lenze Antriebstechnik |26.12.2023|11:26|-010-| ------------------------------------------------------------------------------