PRBT-0416 SGConfig 11.1 Release Notification V100 R0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

GE

Grid Solutions

SGConfig Configuration Tool v11.1 R0 Product Bulletin


Date: December 11th, 2018 Classification: GE Information Publication Number: PRBT-0416

Release Notification of SGConfig 11.1


SGConfig is a PC software-based user interface that allows users of GE Substation Gateways to efficiently manage configuration
files for the D20, D20MX, D25, iBox series of substation controllers and for the D400 and DMC490 Gateway devices.

SGConfig 11.1 includes all the functionality available in the ConfigPro software, provides enhanced visual representation of your
substation hardware configuration and device software configuration.

SGConfig™ version 11.1 encompasses all the features of the following software products:
• SGConfig 11.0 and prior.
• ConfigPro™, the previous configuration tool for the GE Grid Solutions D20*, D200*, D25*, and iBox* product lines.
• D400™ Utilities version 3.0.0 and earlier releases of the IEC 61850 Loader.

Before Installation
To ensure the best user experience, it is highly recommended that you install the MicrosoftTM Excel add-in.
This Excel add-in only works with the 32-bit versions of MicrosoftTM Excel.
Installation of the MicrosoftTM Excel add-in is provided as an SGConfig installation wizard option.
This version of SGConfig supports D20MX v1.8 firmware.

Introduction of DS Agile Studio (DSAS)


Please note that SGConfig 11.1 will likely be the last version of SGConfig. Towards the end of 2018, DS Agile Studio (DSAS) will be
introduced. DSAS will include: D2x Studio, for configuring the D2x devices (D20MX, D200, D20ME, D25, IBOX, etc), and MCP Studio,
for configuring D400 and Multi-Function Controller Platform devices (G500, etc).

DSAS will also feature speed improvements, advanced editor capabilities, and other new features. Please contact
[email protected] if you would like to join the DSAS beta program, for an early preview of the software.

SGConfig v11.1 Enhancements


• Added support for side-by-side installation of DS Agile Studio (DSAS)
• Eliminated the need to reboot after an upgrade install.
• Reduced the time required to perform an upgrade unstill.
• Restored the ability to display programs on multiple processors/partitions in the LogicLinx 32-bit editor.
• Added support for specifying the default custom LogicLinx library in the LogicLinx 32-bit editor and optionally using this
when opening LogicLinx programs migrated from the 16-bit editor.
• Added support for including custom LogicLinx libraries when exporting a solution to the file system in the LogicLinx 32-bit
editor.
• Added support for migrating certain ConfigPro archives with missing Paradox tables.

© 2018 General Electric Company. All rights reserved.


* Trademarks of General Electric Company.
PRBT-0416 V1.00 R0
Product Bulletin
SGConfig v11.1 Resolved Issues
• Resolved an issue where using the D20MX "Firmware & Config Update" command would result in a "Length cannot be
less than zero" error on certain computers.
• Addressed problem that prevented the Firmware & Config Update operation from completing on D20MXv1.10 devices.
• Addressed problem with opening LogicLinx SFC and Ladder programs.
• Addressed problem that caused an ACP error to be displayed when using the LogicLinx 32-bit editor.
• Addressed problem that caused a death signal exception to occur after an ACP error was displayed in the LogicLinx 32-
bit editor and the configuration was downloaded to a D20/D200 device.
• Resolved an issue where Functional Block diagram programs were converted to a Structured Text program in LogicLinx
32-bit Editor
• Resolved an issue where SGConfig was unable to be restored by clicking on the taskbar icon after being minimized
• Resolved an issue where SGConfig extracts the package for D400/DMC490 every time an operation is performed on the
respective device after a restart is done to SGConfig. It only extracts the D400/DMC490 package once after installation.
• Resolved an issue where the D400/DMC490 devices offline/online editor is launched in a small window in the top left
corner of the application
• Resolved an issue where the D400/DMC490 Offline Editor appears in front of other applications opened when the user is
alternating between SGConfig and other applications through ALT+TAB buttons from the keyboard
• Resolved an issue where the recreation of a D2x device from UPL file continued to execute in a loop during the
"Rebuilding application tables" process
• Resolved an issue where it was not possible to map DNP DPA points in the Advanced Editor

Microsoft® Windows® OS Support


SGConfig 11.1 supports the following operating systems:
• Microsoft Windows 10 Professional, all versions with 4 GB RAM.
• Microsoft Windows 7 Professional, Enterprise and Ultimate 32-bit with 4 GB RAM.
• Microsoft Windows 7 Professional, Enterprise and Ultimate 64-bit with 4 or more GB RAM.
SGConfig 8.5 was the last version of SGConfig with support for Windows XP.

Support is not provided for versions of this product that are installed on operating systems other than those identified above, as
the operation of this product has not been verified for any other combinations of operating systems.

Firewall Exceptions
Users are notified of and can approve the creation of any firewall exceptions required for the correct functioning of the SGConfig
11.1 application.

LogicLinx 32-bit Editor Version 3.21


The LogicLinx 32-bit editor:
• Can be used on all Windows operating systems including 64-bit versions
• Does not require SGConfig to be run in elevated mode (i.e., run As Administrator)
• Can compile all programs supported by the LogicLinx 16-bit editor except for the following program types which cannot be
created or modified:
– Instruction language (IL)
– Function chart (FC)
• Can create and modify programs that can be opened and modified by the 16-bit editor provided these programs do not
exceed the limitations of the 16-bit editor

PRBT-0416 2 GE Information
Product Bulletin
LogicLinx 32-bit editor upgrade from v3.0/v3.1/v3.2 to v3.21
Upgrading from LogicLinx Editor 3.0/3.1/3.2 to 3.21 can be performed during the installation of SGConfig 11.1 or by using the
Upgrade LogicLinx 32-bit Editor shortcut after installing SGConfig 11.1. These installations manage the entire upgrade from
v3.0/v3.1/v3.2 to v3.21, and no uninstall of components is necessary.
In addition, all licenses from v3.0/3.1/v3.2 will work with v3.21 at no additional cost.

Evaluation license
The LogicLinx 32-bit editor is delivered with a 60-day evaluation license.
There is a difference between the evaluation license start dates for the LogicLinx 16-bit editor and the LogicLinx 32-bit editor. The
LogicLinx editor evaluation license starts:
• Immediately when the LogicLinx 16-bit editor is installed and is available for a 30-day period.
• The first time the LogicLinx 32-bit editor is launched and is available for a 60-day period. That is, the evaluation period
does not start when the LogicLinx 32-bit editor is installed.
• After the evaluation license expires, you are not able to use the LogicLinx 32-bit editor. To resume use of the LogicLinx 32-
bit Editor, you will need to purchase a Software license or a USB dongle.

Purchase a LogicLinx 32-bit Editor License


You can order the LogicLinx 32-bit editor as either a:
• Software license
o A software license can only be used on a single computer.
o Evaluation and Software licenses are obtained through the SGConfig Global System Preferences > Licensing tab.
or a
• USB dongle
o A USB dongle can be used on multiple computers.
o USB dongles are obtained by contacting GE Grid Solutions sales at: [email protected].

Frequently Asked Questions


Q1: Are configurations created in ConfigPro and earlier versions of SGConfig compatible with SGConfig v11.1?
A: Existing configurations created using any version of ConfigPro, and earlier versions of SGConfig can be converted to SGConfig
v11.1 format.
Configurations created in SGConfig cannot be used in ConfigPro.
Configurations created in SGConfig 11.1 can be used in 11.0 and can be archived in 10.0 format for use in SGConfig 10.0 but
cannot be used in versions of SGConfig earlier than 10.0.
Q2: Where are the Application Definitions stored in SGConfig?
A: Application definitions are stored in the SGConfig database. SGConfig is provided with a complete set of the application
definitions for all applications including latest versions as of the date of the release of the SGConfig Software. New
applications and enhancements for existing applications are continuously being developed. Please visit GE Grid Automation
technical support website for information on product updates. New application definitions can be imported using the
Migration Wizard.

PRBT-0416 3 GE Information
Product Bulletin
Q3: Are configurations stored in a single default directory, as they are in ConfigPro?
A: One of the main differences between the legacy ConfigPro Setup software and SGConfig is the internal architecture of the
product. ConfigPro is based on a file system for archival of configuration data. To enable long term product sustainability
and expandability of the SGConfig software, the architecture of the setup software was re-designed to operate using a
database architecture for data management. Configurations in SGConfig are stored inside of the repository of the SQL
Database and a single external file.
Q4: Can a configuration built in SGConfig v11.1 be used in earlier versions of SGConfig?
A: Partially. The design of SGConfig v11.x is slightly different from that of previous versions of SGConfig. While configurations
built in earlier versions of SGConfig can be restored in SGConfig v11.1, configurations built in SGConfig v11.1 have the
following restrictions:
• SGConfig 11.1 configurations can be used in SGConfig 11.0 without any restrictions
• SGConfig 11.x configurations can be saved in SGConfig 10.0 format for use in SGConfig 10.0.
• SGConfig 11.x configurations cannot be used in versions prior to SGConfig 10.0.
• SGConfig configurations cannot be used in ConfigPro.

Additional Information
For more detailed information on the SGConfig v11.1 release, see the SGConfig 11.1 tool > Getting Started > Release Notes.
For more information on the new features provided in SGConfig v11.1 release, see the SGConfig online help Contents tab >
SGConfig book > What’s New topic.
Visit GE Substation Automation technical support website for software updates: http://sc.ge.com/*SASTechSupport

Product Support
If you need help with any aspect of your GE Grid Solutions product, you can:
• Access the GE Grid Solutions Web site
• Search the GE Technical Support library
• Contact Technical Support

GE Grid Solutions Web Site


The GE Grid Solutions Web site provides fast access to technical information, such as manuals, release notes and knowledge base
topics.
Visit us on the Web at: http://www.gegridsolutions.com

GE Technical Support Library


This site serves as a document repository for post-sales requests. To get access to the Technical Support Web site, go to:
http://sc.ge.com/*SASTechSupport

Contact Technical Support


GE Grid Solutions Technical Support is open 24 hours a day, seven days a week for you to talk directly to a GE representative.
In the U.S. and Canada, call toll-free: 1 800 547 8629.
International customers call: +1 905 927 7070
Or send an e-mail to: [email protected]

PRBT-0416 4 GE Information
Product Bulletin
Copyright Notice
© 2018, General Electric Company. All rights reserved.
The information contained in this online publication is the exclusive property of General Electric Company, except as otherwise
indicated. You may view, copy and print documents and graphics incorporated in this online publication (the “Documents”) subject
to the following: (1) the Documents may be used solely for personal, informational, non-commercial purposes; (2) the Documents
may not be modified or altered in any way; and (3) General Electric Company withholds permission for making the Documents or
any portion thereof accessible via the internet. Except as expressly provided herein, you may not use, copy, print, display,
reproduce, publish, license, post, transmit or distribute the Documents in whole or in part without the prior written permission of
General Electric Company. If applicable, any use, modification, reproduction, release, performance, display, or disclosure of the
Software Product and Associated Material by the U.S. Government shall be governed solely by the terms of the License Agreement
and shall be prohibited except to the extent expressly permitted by the terms of the License Agreement.
The information contained in this online publication is subject to change without notice. The software described in this online
publication is supplied under license and may be used or copied only in accordance with the terms of such license.

Trademark Notice
GE and the GE monogram are trademarks and service marks of General Electric Company.
* Trademarks of General Electric Company. Other company or product names mentioned in this document may be trademarks or
registered trademarks of their respective companies.

Document Revision History


Version Revision Date Author Change Description
1.00 0 December 11th, 2018 Kenny Odetunde Initial Release

PRBT-0416 5 GE Information