Imsnc 03 Operator LC en
Imsnc 03 Operator LC en
Imsnc 03 Operator LC en
October 2010
Document ULC-03-V3.10-10EN
TABLE OF CONTENTS
MACHINE CO-ORDINATE SYSTEM .............................................. 4
CONTROL COMPUTER.................................................................. 4
Display ..........................................................................................................................................4
Manual control and indicating elements ...................................................................................4
Laser switch (ON/OFF) ........................................................................................................5
High voltage (ON/OFF) ........................................................................................................5
Shutter interlock ..................................................................................................................5
Motor power supply (green pushbutton/indicator) ..........................................................5
Emergency STOP button ....................................................................................................6
Motor run key .......................................................................................................................6
Operator interface software........................................................................................................6
Status window..............................................................................................................................7
Heading.................................................................................................................................7
Status bar .............................................................................................................................7
Lower part of status bar......................................................................................................9
Control program menu..............................................................................................................11
Bubble help ........................................................................................................................11
[F2] Cutting machine .........................................................................................................11
[F2] Movements (menu) ................................................................................................................ 12
[F6] Setting arbitrary target point ................................................................................................................13
[F3] Load NC program (menu) ...................................................................................................... 14
[F9] Compilation of NC program (menu).....................................................................................................15
[F4] Run NC program from line (menu)......................................................................................... 15
[F6] Status window and desktop settings (menu).......................................................................... 18
[F7] Tool parameters (menu)......................................................................................................... 20
Display of tool case and tool stack .............................................................................................................20
Display of tools parameters........................................................................................................................23
[F8] Testrun................................................................................................................................... 24
[F10] Operation of rotary positioning unit in XY mode (optional) ................................................... 24
[F11] / [S11] Operation of rotary positioning unit (optional) ........................................................... 25
Definition of pipe cutting operation mode ...................................................................................... 25
[S1] Auxiliary functions (menu)...................................................................................................... 26
[F2] Machine initialisation ...........................................................................................................................26
[F3] Bypass emergency switches ...............................................................................................................26
[F4] Auxiliary functions for extraction..........................................................................................................26
[F6] Calibration of Precitech laser head......................................................................................................29
[F7] Setting machine squareness ...............................................................................................................33
[S2] Machine initialisation without machine movement ...............................................................................35
[S3] Laser auxiliary functions .....................................................................................................................35
[S2] Setting reference points (menu)............................................................................................. 36
[S3] Edit NC program (menu)........................................................................................................ 36
[S6] Picture NC program (menu)................................................................................................... 37
iMSNC [LC] Operator interface 3/47
+Z
+X
+Y 0
Control computer
Display
Caution: The system comprises liquid crystals display, which is not allowed to
be operated at temperatures below freezing point.
When the system is turned on at lower temperatures, the display can be
damaged, possibly leading to malfunctioning of the system.
Touchscreen
Green
Mouse pushbutton
The laser switch is used for switching on the provided that laser generator has
been started using the key. After completing the laser start-up procedure, the
laser generator is ready for turning on high voltage.
The switch is used to turn on high voltage of the laser generator provided that
laser source control unit enables high voltage.
Shutter interlock
Safety switch for shutter interlock is connected in series with “Shutter On”
signal. It is used to ensure that shutter opening is electrically disabled, e.g.
during cleaning or replacement of mirrors, or any manipulation performed in the
delivery path of the laser beam.
Green pushbutton is used to turn on power supply for motors. When the power
is on, the green indicator is lit.
iMSNC [LC] Operator interface 6/47
Emergency STOP button enables to turn off power supply for motors and
technology source. The button is intended for use only in emergency situations.
Note: Emergency stop button on laser source switches off only the laser
source. Power voltage for machine drives will be switched off be the machine
control system as a result of switching laser off.
The motor run key is used to disable any machine motion with power voltage
switched on.
Status window
Status window is an information window that is permanently displayed in the
upper part of the computer screen. The window informs an operator about
actual state of control system functions.
Status window is divided into two sections, heading and system status bar. In
the lower part of status bar there is a variable status info line according to actual
configuration of windows. Status line serves also for displaying error messages.
Heading
Status window heading contains company logo, file name and actual date and
time.
Fig. 5. Heading
Beside this, during program edit the line contains also cursor position line and
column number, otherwise it contains title of submenu. It contains also an icon
for bubble help.
Status bar
Look of the status bar is variable depending on actual operation mode of the
machine and setting of screen layout. The look of the status bar in different
situations is illustrated in Fig. 7 to Fig. 9.
Symbols displayed in status bar inform about actual state of control system
functions. These symbols have following meanings:
Automatic mode
Non-initialised state
Machine dwelling:
Due to execution of dwell instruction „G4“,
„M00“, or „M01“ code executed, control system waits for [START] button.
Fast speed
Bubble help
After clicking on the “bubble” icon in the system heading, the colour of the
bubble icon changes from white to yellow and the system is prepared for bubble
help. Next click on arbitrary key or icon displays the bubble with short
explanation help text. After short time the help is automatically switched off and
with the next click on the key returns it into its normal function.
Fig. 14. Button for switching on and displayed bubble help information
Fig. 16. Cutting machine menu with functions for rotary positioner
[F5] Run loaded NC program. Execution of the program is started from actual position
of the head. The system is switched into automatic mode.
[F6] Status window and desktop setting - menu (see page 18)
[F8] Enable/disable “Testrun” mode. Program in “Testrun” mode is executed with speed
set for manual movements
[F10] Switch on XY pipe cutting mode
[S4] Reset NC program. Stop automatic mode and switch to manual mode
[S5] Stop NC program. Stop automatic mode and switch to break mode
[S12] Accept and clear displayed error messages, warnings and messages
[F6] Move to arbitrary point. The function opens a screen for adjustment of [X, Y] co-
ordinates of target arbitrary point – menu (page 13)
[F9] Reset relative co-ordinates
[S12] Accept and clear displayed error messages, warnings and messages
[S12] Accept and clear displayed error messages, warnings and messages
[S12] Accept and clear displayed error messages, warnings and messages
iMSNC [LC] Operator interface 15/47
When a program is run from specific line, the machine reads the program up to
the entered line and moves the tool to the position corresponding to the entered
line. Then it stays in “program interrupted” status. An operator can verify
whether the entered position is correct and when necessary, it is possible to
iMSNC [LC] Operator interface 16/47
modify the initial position of cutting in test run or retrace mode. To begin cutting
button [START] should be pressed.
Function “Forward motion along contour according to the selected program
while button is pressed” simplifies finding of exact initial position for cutting. The
function is accessed by simultaneous pressing of button [SHIFT] on UVP panel
and [START] on RO2 panel. The machine is switched to test run mode and
moves forward. Machine stops after button [START] is released. Function “Stop
after cutting is finished” simplifies the process of interrupting the program
without damaging cutting. It is accessed by simultaneous pressing of button
[SHIFT] on UVP panel and [STOP] on RO2 panel. Program is interrupted on
the next „M5“ command (tool switch-off).
After a NC program is interrupted important data are saved in database. After
re-reading the NC program, database system reads data of the program from a
database and displays the window „Restore settings“. An operator can select
the data read from the database, there is an option to read line number where
the program was interrupted. It is also possible to enter line number directly or
find the line number that is closest to the actual tool position.
Start program from actual position: Control system recalculates a part of the
[F4] program prior to entered line, assumed starting position are the actual co-ordinates and
the program sis started from entered line number (Fig. 25)
Start from starting point: Control system recalculates a part of the program prior to
[F5] entered line, assumed starting position is the last recent starting point and the program
sis started from entered line number (Fig. 26)
st
[F6] Set actual position as starting point – at the same time, it is the 1 point of rotation
nd
[F7] Save 2 point of rotation and subsequent calculation of angle of rotation
[S4] Program reset: Execution of NC program is terminated and system enters manual
mode
[S5] Stop program: Execution of NC program is interrupted.
[S12] Accept and clear displayed error messages, warnings and messages
Read line from database. Line number where program was last time interrupted
is saved in database. Function reads this line number and displays it in window.
Line number nearest to the actual tool position. This function finds line number,
which is nearest to the actual tool position.
Fig. 27. Menu for status bar and desktop window adjustment
[F2] Desktop setting: cutting plan and actual status of selected tool (Fig. 28), status
window layout as for [F5]
Desktop setting: cutting plan and program source code (Fig. 29), status window
[F3]
layout as for [F6]
[S1] Desktop setting: cutting plan (Fig. 30), status window layout as for [F6]
[S3] Desktop setting: program source code (Fig. 31), status window layout as for [F6]
[S12] Accept and clear displayed error messages, warnings and messages
iMSNC [LC] Operator interface 19/47
Fig. 28. Desktop layout containing cutting plan and actual status of selected tool
Fig. 29. Desktop layout containing cutting plan and source code of NC program
iMSNC [LC] Operator interface 20/47
[F1] Set selected tool as active and send parameters to corresponding THC axis
[S12] Accept and clear displayed error messages, warnings and messages
Fig. 35. Tool parameters summary displayed in internet browser window !IS!
Parameters of some technologies are organised in several groups enabling
more accurate setting of parameter values for different technological operations.
Individual parameters in groups are identical but their values might be different.
Parameters of tools are split into several sets (screens) for more convenient
and comfortable viewing and editing.
iMSNC [LC] Operator interface 23/47
[S10] Switch display of parameter values for actual technological operation / for all
technological operations (Fig. 38 and Fig. 39)
[S11] Change display mode of tool parameters
[S12] Accept and clear displayed error messages, warnings and messages
[F8] Testrun
The function is used to enable or disable testrun mode. Enabled testrun mode is
indicated by corresponding icon in the status window and on manual control
panels UVP51.
For operation of the machine with a rotary positioning unit see description in the
following section. The operation in XY mode means that Y-co-ordinate is not
fixed by the position of pipe axis.
iMSNC [LC] Operator interface 25/47
The rotating unit enables to cut shapes on a rotary surface of a pipe. A pipe is
secured on one side to adjustable jaws of the chuck driven by a servodrive for
rotary positioner, and axially supported by supporting wheels. Securing
elements are installed either on a side of cutting table, or directly on the table.
Pipe axis is parallel either to X or Y axis of the machine. The cutting head cuts
in the highest place of the pipe and moves only along its longitudinal axis.
Speed of movement in the axis is given by „cutting speed“ value in tool
parameters and correspond to material type and thickness of the pipe wall.
Movement in the second direction is provided by a servodrive of rotary
positioner. Based on the cutting speed, the control system calculates
corresponding rotational speed. The calculation uses outer diameter of the pipe
entered into the system manually and actual cutting speed. Hole or part from
the cutting program is cut in the same manner as in planar sheets.
The machine is operated by default in operation mode for planar cutting. When
pipe cutting is required, necessary, [F11] function should be used (switch on
pipe cutting mode). Then a window for entering pipe diameter is displayed:
[S12] Accept and clear displayed error messages, warnings and messages
The function enables to switch on power voltage for motors even in case when
an emergency switch is active. Bypass is enabled only for short time in order to
maintain safety functions of a machine.
[S12] Accept and clear displayed error messages, warnings and messages
Fig. 46. User interface of Precitec distance controller EG8010 for capacitive sensors
iMSNC [LC] Operator interface 30/47
Fig. 47. Diagram of configuration process for clearance measurement system (taken from
distance controller manual)
This process sets the linearization table in EG8010 unit and is necessary for
accurate height measurement.
The calibration process is controlled via manual operator panel UVP. The
process is carried out in following steps:
Calibration start
Calibration process
If the start point is too low, i.e. the head pushes the nozzle to the sheet, it can
happen that the calibration fails at the last step, when it measures at 0.2 mm
standoff and there is still a contact with the sheet.
A contact is indicated on display, so the status changes to “TOUCH
DETECTED”:
The head moves automatically to preset standoffs (steps 115) and calibrates
the sensor unit.
If the calibration was successful, status displayed on the screen changes to
“SUCCESS”:
[F2] Selection window for entering diagonal length of cut model rectangle Da
[F4] Selection window for entering designation of motor on position Xa (side of machine
zero). By default Xa = X1
[F7] Selection window for setting final shifting (password protected – the function can be
used only by servicing technicians)
[F12] Return to previous menu
[S7] Selection window for entering correction value in X1-axis direction (provided the
value is known)
[S8] Selection window for entering correction value in X2-axis direction (provided the
value is known)
[S12] Accept and clear displayed error messages, warnings and messages
Fig. 58. Laser status display for Slab DC20 laser source !IS!
[S12] Accept and clear displayed error messages, warnings and messages
iMSNC [LC] Operator interface 36/47
[S9] Switch between relative and absolute co-ordinates. Relative co-ordinates are
displayed with respect to the point entered by [F9]
[S12] Accept and clear displayed error messages, warnings and messages
[F4] Move up
[F5] Zoom in
[S12] Accept and clear displayed error messages, warnings and messages
iMSNC [LC] Operator interface 38/47
Traverse height during execution NC program. Height can have two values defined
[F2] in tool parameters. After traverse movement in set height, next operation is
performed without IHS.
[F3] Dryrun with disabled technology
[F7] Global marking – tool starts are replaced by marking points. Movement of tool is
governed by commands for tool start, not along cutting contour.
[F8] Load default settings for automatic mode: scale 100 %, no mirroring and no rotation
[S8] Rotate plan by angle. Rotation angle in degrees is displayed in status window
[S12] Accept and clear displayed error messages, warnings and messages
[F2] Edit X co-ordinate of entered rotation point. Entered value is confirmed by [ENTER]
[F3] Edit Y co-ordinate of entered rotation point. Entered value is confirmed by [ENTER]
[S12] Accept and clear displayed error messages, warnings and messages
[F4] Set exchanger to free position, remove bed from the machine, and insert into
exchanger
[F5] Run conveyor for scrap removal
[S12] Accept and clear displayed error messages, warnings and messages
Fig. 69. Dialogue window for entering exchange travel speed in [Hz]
[F3] Asper
[F5] Service
[F3] Counters and timers for tools - menu (see page 42)
[F9] Registration
[S12] Accept and clear displayed error messages, warnings and messages
[S1] Reset counters and timers for all tools of selected group ([Sx] resets group No. x)
[S12] Accept and clear displayed error messages, warnings and messages
Number of timer groups matches the number of used tool, maximum number is
limited to six.
iMSNC [LC] Operator interface 43/47
The function is used when an operator quits iMSNC and wants to continue to
work on a computer.
Fig. 75. Dialogue window displayed when “Quit to Windows” function is used
[F9] Registration
Fig. 77. Window for entering text of remark into history logs
iMSNC [LC] Operator interface 44/47
[F10] Shutdown
Fig. 78. Manual control panel RO2 for one head – schematic and real view
A6 Park tool
Button
C4 Return to contour
C6 Reset program
iMSNC [LC] Operator interface 46/47
Button
On: fast
E1 Speed setting Flashing: cutting
Off: slow
E2 Move X axis, direction (+)
Button
F2 -F Override – decrease speed scale
F3 +F Override – increase speed scale
ATHC enabled – Increase reference value
F4 +Z
ATHC disabled – Move Z axis up, direction (+)
ATHC enabled – Decrease reference value
F5 -Z
ATHC disabled – Move Z axis down, direction (-)
Diode
I1 %F Override – speed scale different from 100 %
Pointer devices
Term “pointer device” denotes all devices intended to assist machine operator
to position the tool into required location (e.g. laser diode, camera).
Pointer device is switched on by pressing [Fn+9] on UVP manual control panel.
Its activity is indicated by text “LD” displayed instead of Y co-ordinate on UVP
display.
After the pointer device is positioned into desired position, the machine is
returned back by repeated pressing of [Fn+9]. The pointer is then switched off.