2022-Cam Switches 18102021
2022-Cam Switches 18102021
2022-Cam Switches 18102021
Page
General 194
Approvals 195
Informations 196
Cam Switches 198
Basic designs 200
Dimensions 262
Cam switches 262
Load switches 266
Accessories 267
D946E 193
General
Test Authorities, Registration Mark, Approvals CE-Marking
Low voltage switchgear from Benedict GmbH is built and The manufacturer has to sign his products with the CE-Marking. With
tested to national and international specifications. All devices the CE-Marking the manufacturer confirms the accordance with the
suit all important specifications without any test obligation, like different EEC Directives. The CE-Marking is absolutely necessary to sell
VDE, BS and also relative to IEC Recommendations and to the products in the EEC.
European Standards like IEC 947 and EN 60947. Below you find the EEC Directives concerning our products.
It is for this reason of our Low voltage switchgear is used all over the world. Low Voltage Directive 2006/95/EC
In order to provide special versions, limitations to the max. voltages, EMC Directive 2004/108/EC
currents and power ratings or special markings are sometimes necessary. RoHS + WEEE 2002/95/EC + "002/96/EC
Explanations for choice and supply of low voltage switchgear in Canada and USA
Marking of auxiliary contacts
At several devices in UL-data are two voltages for auxiliary contacts men- Low voltage switchgear for auxiliary circuits (e. g. contactor relays, control
tioned (e. g.: 600 volts at same potential, 150 volts at different potentials). units, auxiliary contacts in general) usually approved for "Heavy Duty" or
That means, if the voltage is higher than 150 volts, the control voltage "Standard Duty" UL and besides these marked with the admissible max.
applied to input terminals must be at the same potential. voltage or with short codes (see table).
Standard Duty AC 120 30 3 5 B150 Devices as components approved for Devices approved for "field wiring",
(SD or STD DTY) AC 240 15 1,5 5 B300 "factory wiring":
AC 480 7,5 0,75 5 B600 devices for employment in control
AC 600 6 0,6 5 B600 panels, when they are selected, a) devices for employment
mounted and wired according to in control panels, when
DC 125 1,1 1,1 5 P150 the charging conditions by skilled they are mounted and
DC 250 0,55 0,55 5 P300 worker. wired by skilled worker.
DC 600 0,2 0,2 5 P600 b) devices for retail in USA
- AC 120 15 1,5 2,5 C150
AC 240 7,5 0,75 2,5 C300
AC 480 3,75 0,375 2,5 C600 Valid UL-Standards: Valid UL-Standards:
AC 600 3 0,3 2,5 C600 UL 508 "Standard for Industrial UL 508 "Standard for Industrial Control
DC 125 0,55 0,55 2,5 Q150 Control Equipment" Equipment" (unlimited)
DC 250 0,27 0,27 2,5 Q300 (partly limited)
DC 600 0,1 0,1 2,5 Q600
194 D946E
Approvals
Type
Cam Switches (UL-Listed as MANUAL MOTOR CONTROLLER and suitable as MOTOR DISCONNECT)
M10 o / o o -
M10H o / o o o
M20 o / o o -
N20 o / o o -
N33F o / o o -
N40 - / o o -
N61 o / o o -
N80 o / o o -
N100 o / o o -
N200 o / o o -
L400 o / - - -
D946E 195
Technical Information
Degree of protection acc. to IEC 60947-1
Protection ratings are prefixed by the internationally agreed letters IP 2 nd Short description Definition
followed by two digits. digit
1 st digit: Pertains to solid objects 1 Protected against Dripping water (vertically falling drops)
2 nd digit: Pertains to water. dripping water shall have no harmful effect.
3 Protected against Excludes solid objects exceeding 2,5 mm 6 Protected against Water from heavy seas or water
solid objects in diameter or thickness. heavy seas projected in powerful jets shall not
greater than 2,5mm enter the enclosure in harmful
quanties.
4 Protected against Excludes solid objects exceeding 1 mm
solid objects in diameter or thickness. 7 Protected against Ingress of water in a harmful quantity
greater than 1 mm the effects of shall not be possible when the
immersion enclosure is immersed in water under
5 Dust protected Prevents ingress of dust in quantities standard conditions of pressure and
and locations that would interfere with time.
the intended operation of the equipment.
8 Protected against No ingress of water.
6 Dust tight Prevents ingress of dust. submersion
Mounting positions
No limitations, all kind of postitions allowed.
196 D946E
Technical Information
Terminal screws
Devices Kind of connection
Screw with 2 Screw s Screw with Screw driver Tightening torque
Type washer w. nut Nm lb. inch
Cam Switches
M4H.. M2,5 - - Pz1 0,6 5
N200 - - M10 10 88
D946E 197
Ratings Designs
Panel moun. Single hole mount. Ø22,5mm Flush mount.
Protection degree from front M10H, M20 IP65 with Plate without Plate IP40
in mounted position IP40 IP65 IP65
Escutcheon frame Up to 25
Switching cells - two poles
- double interruption per pole
Escutcheon plate
Drive shaft
of solid aluminium
Handle
Four-hole mounting ....E..
or single-hole mounting Ø 22,5 mm ....Z..
or base mounting ....V..
or DIN-rail mounting . . . . SM . .
198 D946E
Designs
Base mounting DIN-rail Modular Plastic enclosed Motor switch Terminal box
M10H, M20 IP65 mounting IP40 ..P.. IP40 horizontal, IP65 enclosed mounting
IP40 IP40 ..PF.. IP65 IP65 IP65
- - - - - - -
M10H V ♦ • •
M10H SM ♦ •
M10H SMA ♦ - - M10 PM •♦ -
- - - M10 P(F) •♦ - - M10 KE •♦
M20 V ♦ • •
M20 SM ♦ •
M20 SMA ♦ - - - -
•
N20 V ♦ •
N20 SM ♦ - •
N20 P(F) ♦ - N20 PM •♦ N20 KE •♦
•
N33F V ♦ •
N33F SM ♦ - •
N33F P(F) ♦ - - -
N100 V•♦ - - - - - -
N200 V•♦ - - - - - -
L400 V•♦ - - - - - -
L600 V•♦ - - - - - -
L800 V•♦ - - - - - -
L1200 V•♦ - - - - - -
Ordering
SWITCH TYPE ••
DESIGN ••
SWITCH PROGRAM •
NUMBER OF STEPS •
NUMBER OF POLES ♦
ACCESSORIES +••
On-Off-switch •• •• A♦
M10H E A3+GFP Changeover switch with Off position •• •• U♦
Changeover switch without Off position •• •• W♦
20A Panel mounting Changeover switch with spring return to Off •• •• UR♦
On-Off-switch 3-pole Reversing switch •• •• WU♦
+ large front plate Star-Delta-switch •• •• SD
Multi speed switch •• •• P..
Start switch •• •• SE♦
Stop switch •• •• SA♦
Voltmeter selector switch •• •• V.
Ammeter selector switch •• •• M..
Gang switch GR..
•
•• ••
Multi step switch without Off position ST ♦
•
•• ••
Multi step switch with Off position •• •• ST0 ♦
D946E 199
Panel mounting designs
Switches of the panel mounting designs listed below have protection from E switches. The position of the terminals of the standard switches is left
front IP40. Where a shaft seal (appendix +WD) is used, the protection and right, at switch M10H the terminals are above and below. Where
is increased to IP54. Use of a moisture proofing cap (appendix +FR) a knob insert is turned by 90° (can easily be performed after delivery),
results in an increase in rear protection to IP54. In the standard version, the position of the terminals can be changed.
the switches are delivered with a square escutcheon plate and black Dimensions see page 262.
instrument knob. Forward mounting is possible for some of the design
Panel mounting E X X X X X X
For installation in control panels, ma-
chines and equipment.
For panel thickness of over 5mm,
an extended switch shaft is required
(appendix +VW).
Protection from front:
M10H, M20 IP65
all others IP40
Central fixing 22,5mm Z X X X 2) - - -
Switch for mounting with standard
22,5mm mounting holes and 1-4mm
panel thickness.
Protection from front: IP65
Wrench J7049 necessary
200 D946E
Base mounting designs
Switches of the designs listed below have protection from front IP40. The position of the terminals of the standard switches is left and right,
When a shaft seal (appendix +WD) is used, the front protection at switch M10H the terminals are above and below. Where a knob insert
type is increased to IP54. In the standard version, the switches are is turned by 90° (can easily be performed after delivery), the position
delivered with a square escutcheon plate and black instrument knob of the terminals can be changed.
(design SMA with grey cover and grey toggle knob). Door couplings Dimensions see page 263.
are advisable for switchgear cabinets with hinged doors.
D946E 201
Plastic enclosed switches
The switches, which have durable plastic enclosures, are intended for wall mounting or attachment to machines. In the standard version, they
are supplied with a light-grey enclosure, square escutcheon plate, black markings on a silver background, and a black instrument knob. Other
colours and colour combinations are available for most enclosure types. It is not possible to mount an additional rectangular plate. The enclosure
base is equipped with 4 entry glands with heavy-gauge conduit threads (see drawings). In all types of plastic enclosures, two terminals that are
connected and insulated from switch column can be provided for a PE conductor (appendix +PE). Dimensions see page 264.
202 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
On-Off-switches A
1-pole 60° 1 48 r 20A M10H . x x x x x1) . A1
32A M20 . x x x x - . A1
64 r 32A N20 . x - x - x . A1
50A N33F . x x x - x . A1
88 r 63A N40 . x - x - x . A1 +003
90A N61 . x - x - x . A1
115A N80 . x - x - - . A1
132r 150A N100 . x - x - - . A1
250A N200 . x - x - - . A1
Ordering example: AC21 250A panel mounting, On-Off-switch 6-pole, Escutcheon plate OFF - ON N200 E A6+003
1) Plastic enclosed switches are delivered with switch type M10.
D946E 203
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Changeover switches U
1-pole 60° 1 48 r 20A M10H . x x x x x 1) . U1
32A M20 . x x x x - . U1
64 r 32A N20 . x - x - x . U1
50A N33F . x x x - x . U1
88 r 63A N40 . x - x - x . U1 +007
90A N61 . x - x - x . U1
115A N80 . x - x - - . U1
132r 150A N100 . x - x - - . U1
250A N200 . x - x - - . U1
Ordering example: AC21 250A panel mounting, changeover switch 6-pole, Escutcheon plate 1 - OFF - 2 N200 E U6+007
1) Plastic enclosed switches are delivered with switch type M10.
204 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, changeover switch without off 6-pole, N200 E W6
1) Plastic enclosed switches are delivered with switch type M10.
D946E 205
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Reversing switches WU
2-pole 60° 2 48 r 20A M10H . x x x x x1) . WU2
32A M20 . x x x x - . WU2
64 r 32A N20 . x - x - x . WU2
50A N33F . x x x - x . WU2
88 r 63A N40 . x - x - x . WU2 +007
90A N61 . x - x - x . WU2
115A N80 . x - x - - . WU2
132r 150A N100 . x - x - - . WU2
250A N200 . x - x - - . WU2
Ordering example: AC21 63A base mounting, reversing switch 3-pole, position 2 with spring to off N40 V WU3R1
1) Plastic enclosed switches are delivered with switch type M10.
206 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Star-Delta switches SD
1 rotary direction 60° 4 48 r 20A M10H . x x x x x1) . SD
32A M20 . x x x x - . SD
64 r 32A N20 . x - x - x . SD
50A N33F . x - x - x . SD
88 r 63A N40 . x - x - x . SD
90A N61 . x - x - x . SD
115A N80 . x - x - - . SD
132r 150A N100 . x - x - - . SD
250A N200 . x - x - - . SD
Ordering example: AC21 32A plastic enclosed, star-delta selector switch N20 P SDU
1) Plastic enclosed switches are delivered with switch type M10.
D946E 207
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Star-Delta switches SD
with double outfeed 60° 4 48 r 20A M10H . x x x x x1) - . SDMO
phases for use with 32A M20 . x x x x - - . SDMO
manual motor starter
64 r 32A N20 . x - x - x x . SDMO
50A N33F . x - x - x - . SDMO
88 r 63A N40 . x - x x - . SDMO
90A N61 . x - x - x - . SDMO
115A N80 . x - x - - - . SDMO
132r 150A N100 . x - x - - - . SDMO
250A N200 . x - x - - - . SDMO
Ordering example: AC21 250A panel mounting star-delta switch with brake position N200 E SDB
1) Plastic enclosed switches are delivered with switch type M10.
208 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 63A panel mounting, split phase switch, both rotary directions N40 E HPR1
1) Plastic enclosed switches are delivered with switch type M10.
D946E 209
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 32A cast enclosed, multi speed switch, 1 Dahlander winding, 1 rotary direction N20 G P61
1) Plastic enclosed switches are delivered with switch type M10.
210 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi speed switch, 1 rotary direction, low speed with star-delta-start N200 E P91
1) Plastic enclosed switches are delivered with switch type M10.
D946E 211
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi speed switch, 2 separate windings, low speed with star-delta-start N200 E P96
1) Plastic enclosed switches are delivered with switch type M10.
212 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi speed switch, 1 Dahlander winding A,
1 normal winding B, 3 speeds, both rotary directions N200 E P93R
1) Plastic enclosed switches are delivered with switch type M10.
D946E 213
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A Base mounting, multi speed switch, 2 Dahlander windings, 4 speeds, 1 rotary direction N200 V P124
214 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 63A panel mounting, changeover switch, position 1 latched, position 2 with spring return, 3-pole: N40 E UK3
1) Plastic enclosed switches are delivered with switch type M10.
D946E 215
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Start-Stop switches S
Start-switch,1-pole 30° 1 48 r 20A M10H . x x x x x1) - . SE
32A M20 . x x x x - - . SE
64 r 32A N20 . x - x - x x . SE
50A N33F . x - x - x - . SE
216 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Start-Stop switches S
Stop-switch,1-pole 30° 1 48 r 20A M10H . x x x x x1) - . SA
32A M20 . x x x x - - . SA
64 r 32A N20 . x - x - x x . SA
50A N33F . x - x - x - . SA
88 r 63A N40 . x - x - x - . SA
Ordering example: AC21 50A panel mounting, Start-Stop-switch,1-pole for reversing contactors N33F E S2EA
1) Plastic enclosed switches are delivered with switch type M10.
D946E 217
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 50A panel mounting, Voltmeter selector switch, 3 line voltages and 1 phase voltage N33F E V13
1) Plastic enclosed switches are delivered with switch type M10.
218 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 63A panel mounting, ammeter selector switch, for 3 current transformers 1-pole N40 V M31
1) Plastic enclosed switches are delivered with switch type M10.
D946E 219
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 63A panel mounting, ammeter selector switch, for 4 current transformers 1-pole N40 V M41
1) Plastic enclosed switches are delivered with switch type M10.
220 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Gang switches GR
2 circuits A and B 45° 1 48 r 20A M10H . x x x x x1) - . GR11
1-pole 32A M20 . x x x x - - . GR11
0 - A - A+B
64 r 32A N20 . x - x - x x . GR11
50A N33F . x x x - x - . GR11
88 r 63A N40 . x - x - x - . GR11 +126
90A N61 . x - x - x - . GR11
115A N80 . x - x - - - . GR11
132r 150A N100 . x - x - - - . GR11
250A N200 . x - x - - - . GR11
Ordering example: AC21 250A panel mounting, gang switch, 2 circuits A and B, 3-pole N200 E GR31
1) Plastic enclosed switches are delivered with switch type M10.
D946E 221
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Gang switches GR
2 circuits A and B 45° 3 48 r 20A M10H . x x x x x1) - . GR32
3-pole 32A M20 . x x x x - - . GR32
0 - A - B - A+B
64 r 32A N20 . x - x - x x . GR32
50A N33F . x - x - x - . GR32
88 r 63A N40 . x - x - x - . GR32 +127
90A N61 . x - x - x - . GR32
115A N80 . x - x - - - . GR32
132r 150A N100 . x - x - - - . GR32
250A N200 . x - x - - - . GR32
Ordering example: AC21 250A panel mounting, gang switch, 3 circuits A, B and C, 3-pole N200 E GR33
1) Plastic enclosed switches are delivered with switch type M10.
222 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Series-Parallel switches SP
2 circuits A and B 45° 2 48 r 20A M10H . x x x x x1) - . SP1
2-pole 32A M20 . x x x x - - . SP1
0 - A + B - A,B (parallel)
64 r 32A N20 . x - x - x x . SP1
50A N33F . x x x - x - . SP1
88 r 63A N40 . x - x - x - . SP1 +126
90A N61 . x - x - x - . SP1
115A N80 . x - x - - - . SP1
132r 150A N100 . x - x - - - . SP1
250A N200 . x - x - - - . SP1
Ordering example: AC21 250A panel mounting, series-parallel switch, 2 circuits for 3-phase systems N200 E SP3
1) Plastic enclosed switches are delivered with switch type M10.
D946E 223
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 1-pole without off, 7 steps N200 E ST71
1) Plastic enclosed switches are delivered with switch type M10.
224 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 1-pole without off, 12 steps N200 E ST121
1) Plastic enclosed switches are delivered with switch type M10.
D946E 225
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 1-pole with off, 6 steps N200 E ST061
1) Plastic enclosed switches are delivered with switch type M10.
226 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 1-pole with off, 11 steps N200 E ST0111
1) Plastic enclosed switches are delivered with switch type M10.
D946E 227
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 2-pole without off, 7 steps N200 E ST72
1) Plastic enclosed switches are delivered with switch type M10.
228 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 2-pole without off, 12 steps N200 E ST122
D946E 229
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 2-pole with off, 6 steps N200 E ST062
1) Plastic enclosed switches are delivered with switch type M10.
230 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 2-pole with off, 11 steps N200 E ST0112
D946E 231
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 3-pole without off, 7 steps N200 E ST73
1) Plastic enclosed switches are delivered with switch type M10.
232 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 3-pole without off, 12 steps N200 E ST123
D946E 233
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 3-pole with off, 6 steps N200 E ST063
1) Plastic enclosed switches are delivered with switch type M10.
234 D946E
Switching programs
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size E. Z. V. SMA. P. pro- plate
↓ AC21 ↓ ↓ ↓ ↓ ↓
Ordering example: AC21 250A panel mounting, multi step switch 3-pole with off, 11 steps N200 E ST0113
D946E 235
Mini-Cam Switches M4H
Panel mounting E, IP40 Central fixing Z Central fixing without escutcheon plate ZO
lock
Mounting holes
Single hole mountings are generally delivered for a 16mm (.64") mounting.
Using the forwarded adapter ring, it is possible to alter the single hole mountings from 22mm (.88"). For that
purpose the adapter ring has to be attatched onto the threded part of the body in such a manner, that
1. the flat side of the adapter ring shows towards the front seal and
2. the inner nose fits into the notch of the body.
The adapter ring has to be pushed towards the front seal.
Optional extras ordering for M4H Z ... +SRE M4H Z ... +SA. M4H ZO ... +SA. M4H Z ... +SRE+SA.
code design
M4H mm 30 28 29,5 12,5 38,5 50,5 62,5 74,5 86,5 98,5 110,5 122,5
Technical data
Type
according to AC21A AC15 Motor rating AC3
specifications 110V 380V 3 phase 3-pole 1 phase 2-pole
240V 440V Volt 110 220 380 110 220 380
General use Pilot Duty 120 240 440 120 240 277 440
M4H IEC, VDE, BS, SEV 10A/500V 2,5A 1,5A kW 0,65 1,5 2,2 0,3 0,55 - 0,75
UL, CSA 10A/300V A300 HP 0,75 1 - 0,33 0,75 0,75 -
Type
according to Motor rating AC23 additional data for wiring according to UL and CSA
specifications 3-pole 2-pole
Volt 110 220 380 110 220 380 Type type of temp. rating torque value for
120 240 440 120 240 440 wire of wire field wiring terminals
M4H IEC, VDE, BS, SEV kW 0,75 1,8 3 0,37 0,75 1,1 M4H copper 60/75°C 0,4Nm / 3,5lb - inch
UL, CSA HP - - - - - - wire only
236 D946E
Mini-Cam Switches M4H
Switch programs
Description Wiring diagram AC21 500V 10A escutch. numb. Type Design Switch
AC15 230V 2,5A 30 x 30 of .E. .Z. .ZO. pro-
AC3 4x400V 2,2kW cells ↓ ↓ ↓ gram
On-Off-switch A
1-pole 1 M4H . x x x . A1
2-pole 1 M4H . x x x . A2
3-pole 2 M4H . x x x . A3
4-pole 2 M4H . x x x . A4
6-pole 3 M4H . x x x . A6
Changeover switch U
1-pole 1 M4H . x x x . U1
2-pole 2 M4H . x x x . U2
3-pole 3 M4H . x x x . U3
4-pole 4 M4H . x x x . U4
6-pole 6 M4H . x x x . W6
Reversing switch WU
2-pole 2 M4H . x x x . WU2
Star-delta switch SD
1 rotary direction 4 M4H . x x x . SD
Start switch
1-pole 1 M4H . x x x . SE
D946E 237
Mini-Cam Switches M4H
Switch programs
Description Wiring diagram AC21 500V 10A escutch. numb. Type Design Switch
AC15 230V 2,5A 30 x 30 of .E. .Z. .ZO. pro-
AC3 4x400V 2,2kW cells ↓ ↓ ↓ gram
Start-Stop switch 1 M4H . x x x . SEA
Gang switch GR
2 circuits A and B 1 M4H . x x x . GR11
1-pole
0 - A - A+B
Ordering example: Multi step switch without 0, 3 steps, 3-pole, panel mounting: M4H E ST33
238 D946E
Mini-Cam Switches M4H
Switch programs
Description Wiring diagram AC21 500V 10A escutch. numb. Type Design Switch
AC15 230V 2,5A 30 x 30 of .E. .Z. .ZO. pro-
AC3 4x400V 2,2kW cells ↓ ↓ ↓ gram
Ordering example: Multi step switch with 0, 10 steps, 1-pole, Central fixing without escutcheon plate: M4H ZO ST0101
D946E 239
Load Switches for resistive or slightly inductive loads or switching without load
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size .E. .V. pro- plate
↓ AC21 ↓ ↓ gram
On-Off-switches A
1-pole 60°2 88 r 125A L100 . x x . A1
1 180A L160 . x x . A1
1 132r 400A L400 . x x . A1
3 600A L600 . x x . A1
2 800A L800 . x x . A1
3 1200A L1200 . x x . A1
240 D946E
Load Switches for resistive or slightly inductive loads or switching without load
Description Wiring diagram Switching angle Number of cells Type Design Switch Escutcheon
↓ Size .E. .V. pro- plate
↓ AC21 ↓ ↓ gram
Changeover switches U
1-pole 60° 2 88 r 125A L100 . x x . U1
2 180A L160 . x x . U1
2 132r 400A L400 . x x . U1
3 600A L600 . x x . U1
4 800A L800 . x x . U1
6 1200A L1200 . x x . U1
Ordering example: AC1 1200A panel mounting, changeover switch without off 4-pole L1200 E W4
D946E 241
Operating Knobs and Handles
Types of handles
In the standard version, the switches are supplied with a black twist knob All operating knobs can be moved on the hexagonal shaft, to permit
or instrument knob (M10H - N33F), except for design SMA, which has adaptation to different sheet thicknesses, etc.
a grey toggle knob. Switches of size L, which consist of 2 or 3 switch
columns, come with a black hand wheel. If required, the switch can Type N100
be supplied with other knobs, which can later easily be exchanged. N40 N200
All operating knobs have an insert, which sets the position of the knob N61 L400
in relation to the switch shaft. This insert can be mounted in 8 different M10 N80 L600
positions (at intervals of 45°), causing the angle of each individual switch M10H N20 L100 L800
setting to be rotated by 45°. M20 N33F L160 L1200
Knob movement mm 5 5 7 9
Hexagonal shaft dimension mm 5 7 9 12
In the standard version, the ~ 0,3 Nm
switch terminals are posi- Ordering example: Cam switch N61 V U3 with Instrument knob red
tioned left and right (except Order type: N61 V U3 +G3
M10H). When the knob insert Dimensions see page 267
is turned by 90°, the lay-out
of the terminals changes to N100
top and bottom. N40 N200
N61 L400
M10 N80 L600
Knobs and handles Ordering M10H N20 L100 L800
Description Colour Code M20 N33F L160 L1200
Instrument knob
grey +G1 X X
Standard for M10 to N200
black +G2 X X X X
red +G3 X X
white +G5 X X
242 D946E
Escutcheon Plates
TELUX-Cam Switches in designs E, V, P, PF, SM, UP, Z and KE are Special engraved markings on escutcheon plates are limited by
supplied with a square escutcheon plate consisting of a black frame the available space. In the case of relatively large production runs
and plexi insert plate. The markings are printed in black are on the or frequent use of the text, we recommend ordering of a printing
back of the insert plate. To protect the markings so that they remain block. This will be invoiced at cost price, and the engraving will not
easy to read, the back of the insert plate is lined with silver foil. In be charged for. This investment generally pays with batches from 50
addition, rectangular plates can be provided for all switch sizes, which pieces upwards.
can fitted on all switches after mounting. The "escutcheon plate" column of the selection and ordering tables for
switch programs indicates the standard plate and, in some cases, an
Square plate Rectangular plate additional plate that is often used for the programs in question. If such
(with square plate) a plate, listed in the selection table, is desired, the appropriate code
Slot on the cover plate number should be stated when ordering a switch and switch program.
upper side
Should only plates or parts of the latter be ordered, the order type
is assembled as shown by the following example.
Order type:
A85081
Switch size Plate Marking
Preferred position of the slot Slot for additional plate
Code letter Art.No. for Code number
on bottom of
for M10, M10H standard plate with label
the cover plate
and M20 with markings, MAN - 0 - AUTO
complete angle of rot. 60°
TELUX-Cam Switches in design SMA, for distribution boards with However, if a switch with non-standard lettering is required, only
45mm inside edge of installation cover, is supplied with a grey cover three-digit code number for the marking need be added to the order
and black markings. type (see next page).
D946E 243
Escutcheon Plates
Selected standard markings Code letter of switch sizes
The markings that are most commonly required are shown below,
together with code letters for the switch size and the code number. M10, M10H, M20 A
Ordering example: Switch type M10H E A3 with escutcheon plate N20, N33F E
"OFF ON" and additional rectangular escutcheon plate "PUMP" N40, N61, N80, L100, L160 H
Order type: M10H E A3 +003 +516 N100, N200, L400, L600, L800, L1200 L
000 001
AEHL AEHL
012 013 014 016 026 034 043 044 067 068
AEH AE A A A A A A A A
077 086 097 101 102 103 104 105 106 107
A A A AEH AE AE AE AE AE A
108 109 110 111 112 113 114 153 157 191
AE AE AE A AE AE A E A E
219 264 370 371 405 438 455 648 714 749
A A AE A AE A A AE E A
018 019 021 022 025 031 032 036 041 042
AE AEHL A E E A A E A AE
045 051 118 119 120 121 122 123 124 125
A AE AE AE E AE AE AEHL AE AE
126 127 128 129 131 160 221 243 244 247
AE AE AE A E EH A AE AE AE
244 D946E
Escutcheon Plates
A A E AE AE A AE AE
002 003 004 006 007 008 009 010 011 015
081 082 088 095 132 133 134 136 140 143
AE AE AEH AE AEH AE AE A A A
162 163 166 175 185 186 195 211 241 251
A E A E AEHL A AE EHL A AE
252 266 273 277 279 292 334 338 355 408
A AE A A AEH A A AE A A
416 417 418 419 420 422 439 446 448 489
AE AE AE AE AE AE A AE A A
A A A EH A AH A A A
D946E 245
Escutcheon Plates
Switching angle 90o
028 029 030 056 083 087 089 144 145 217
AE AE AE A AEHL AE AE AEH E A
A E AE A A
Miscellaneous
020 054 071 092 147 148 149 172 225 289
E A A E AEH AE E AE A A
760
500 501 503 504 505 506 509 519 520 524
AEHL AE AE AE A A E AE E AE
534 535 542 543 546 549 550 551 552 556
A A AE A A A A A AE E
557
001 002 003 004 006 009 012 013 014 015
234 243 355 370 416 417 420 636 637 717
246 D946E
Switching angles
PN01 PN02 PN03 PN04 PN05 PN06 PN07 PN08 PN09 PN10
PN11 PN12 PN13 PN14 PN15 PN16 PN17 PN18 PN19 PN20
PN30 PN31 PN32 PN33 PN34 PN35 PN36 PN37 PN38 PN39
PN40 PN41 PN42 PN43 PN44 PN45 PN46 PN47 PN48 PN49
PN50 PN51 PN52 PN53 PN54 PN55 PN56 PN57 PN58 PN59
D946E 247
Switching angles
PN60 PN61 PN62 PN63 PN64 PN65 PN66 PN67 PN68 PN69
PN80 PN82 PN83 PN84 PN85 PN86 PN87 PN88 PN89 PN90
PN91 PN92 PN93 PN94 PN95 PN96 PN97 PN98 PN99 PN100
PN101 PN102 PN103 PN104 PN105 PN106 PN107 PN108 PN109 PN124
PN125 PN126 PN127 PN128 PN129 PN130 PN131
PN110 PN111 PN112 PN113 PN114 PN115 PN116 PN117 PN118 PN119
248 D946E
D946E 249
Door couplings
For switches with door couplings it is necessary to state the installation Door couplings are available for switches to be installed in switchgear
depth - that is, the distance between mounting level of the switch and cabinets or distribution boards with hinged doors. These permit the
the inside edge of the door (dimension T). doors to be openened without removal of the operating knobs.
250 D946E
Lockable switches
Key-operated and lockable switches are supplied with two keys. Ordering example: Cam switch N20 E A3 key operated
Additional keys or other types of lock on request. Order type: N20 E A3 +SA
D946E 251
Padlock devices
A range of padlock devices designed to prevent from being turned on Ordering example: Cam switch N33F E A3 with interlocking device
by unauthorized personnel, or during maintenance and repair work, SV3 suitable for 3 padlocks
can be supplied. Order type: N33F E A3 +SV3
Dimensions see page 272
Padlock device
Standard version black, otherwise 88x88 +SV3 E, V N40, N61, N80
yellow insert plate and red twist knob +SV3R E, V N100, N200, L400, L600,
for 1-3 padlocks. E, V L800, L1200
Shackles up to Ø8,5mm PF N40, N61, N80
Prior to insertion of the first padlock, a
red locking ledge must be depressed. 132x132 +SV3 E, V N40, N61, N80
This indicates that the switch is locked. +SV3R E, V N100, N200, L400, L600,
E, V L800, L1200
PF N40, N61, N80
Padlock device
Standard base grey, locking ring black, 64x64 +SV4 E, V M10H, N20, N33F
or with yellow base and red locking +SV4R SM M10H, N20, N33F
ring. P, PF N20, N33F
Locking ring for 1-3 padlocks.
Shackles up to Ø6mm
Standard base grey, locking ring
black, 88x88 +SV488 E, V N20, N33F
or with yellow base and red locking ring. E, V N40, N61, N80
+SV488R P, PF N40, N61, N80
252 D946E
Switch interlocks
A wide range of locks and interlocking devices, designed to prevent Ordering example: Cam switch N20 E A3 with push button switch lock
accidental or hazardous switching, can be supplied. Order type: N20 E A3 +DV
D946E 253
Couplings and stop mechanism
A range of couplings and stop mechanisms for trouble-free operation Ordering example: Cam switch N200 V ST0113 spread over three
of switches with a very large number of contacts can be supplied. columns interconnected by gears
Dimension see page 274 Order type: N200 V ST0113 +ZK3
Coupling of different switch sizes +ZWK E N40, N61, N80, L100, L160
For attachment of control switches N100, N200, L400, L600,
(auxiliary contacts) to larger switches. L800, L1200
M10H, M20 in sizes E and H.
N20 to N80 in size L.
254 D946E
Special versions
A number of special versions can be supplied for adaptation of switches Ordering example: Cam switch M10H E U3 with large front plate
to various conditions of use. Order type: M10H E U3 +GFP
D946E 255
Accessories
A number of special versions can be supplied for adaptation of switches Ordering example: Cam switch N20 E A3 with terminal cover plate
to various conditions of use. Order type: N20 E A3 +KLAD
Dimensions see page 273
Angled terminals +WK E,V M20, N20, N40, N61, N80, N100
For easy connection of inaccessible
switches.
Unless otherwise stated, all terminals
specified with markings are equipped
in this manner.
A distinction is drawn between left and
right angled terminals. Seen from the
switch end, the left terminals are located
above left and below right; conversely,
right terminals are above right and
below left.
Spare key for key operated switches J7101 E, V, P M10H, M20, N20, N33F,N40
with Lock Willenhal FT101 SMA M10H, M20
256 D946E
Switching Programs according to Customer Requirements
As a result of their modular construction, TELUX cam switches are In all special switches with overall switching angles of less than 180°,
particularly suitable for manufacturing of special variants. According the number of cells required is calculated by having the total number
to its function, each pair of contacts in the switch is adapted to the of contacts in the switching program.
desired program by appropriate design of the cam plate. In the case When planning for switches with special programs, choice of the
of switches with an overall switching angle of more than 180°, provisi- optimum switching angle thus plays an important part. The listing of
on must made for a cam plate in each switching cell, controlling two all the options for lay-out of switch settings, on pages 247 and 248,
opposite, independent contact pairs with matching programs (does should be an aid to planning (position numbers PN).
not apply to M10, M10H, M20 and N20). If special markings are to be engraved on the escutcheon plates, it
Depending on the desired contact program for the special switch, it is vital to take account of the available space. It is advisable to use
may often be impossible to make full use of all switching cells, that is, abbreviations.
to include the maximum possible number of contacts. In determining We provide forms (see page 275) on request, free of charge, to give a
the number of cells or switch length, one-contact cells will sometimes clear overview when special programs are being defined. Switch size,
be resorted to. design, type of operating knob and desired switching angle, as well
Switch sizes M10, M10H, M20 and N20 are exceptions to this rule. Here, as the function of the contacts, are entered on these forms. Provision
two cam plates can be built into each cell, so that both contacts are has also been made in them for entry of details as to escutcheon plate
independently controlled (full use of the cells with special programs). engravings or other special requirements.
Ordering Example
D946E 257
Utilization Categories
For easier choice of devices and in order to make the comparison auiliary contactsaccording to IEC 947-5-1 and VDE 0660 Part 200
of different products simplier are utilization categories for cam determind. The Table below offers divers utilization catagories
switchesaccording to IEC 947-3, VDE 0660 Part 107 and and assorted test conditions.
Kind of Category Typical Rated Test conditions for the number Test conditions for making
current fre- infre- applications operational of on-load operating cycles and breaking capacities
quent quent current (normal service) (operation in fault case)
oper- oper- Make Break Make Break
ation ation I/Ie U/Ue cosϕ Ic/Ie Ur/Ue cosϕ I/Ie U/Ue cosϕ Ic/Ie Ur/Ue cosϕ
AC20A AC20B No-load conditions all values - - - - - - -
- - -
- -
Alter- Switching of resistive loads
nating AC21A AC21B including moderate all values 1 1 0,95 1 1 0,95 1,5 1,05 0,95 1,5 1,05 0,95
Current overloads
Switching of mixed resistive
AC22A AC22B and inductive loads all values 1 1 0,8 1 1 0,8 3 1,05 0,65 3 1,05 0,65
including moderate overloads
Switching of motor loads 0<Ie≤100A 10 1,05 0,45 8 1,05 0,45
AC23A AC23B or other highly inductive all values 1 1 0,65 1 1 0,65
loads 100A<Ie 10 1,05 0,35 8 1,05 0,35
Slip-ring motors:
AC2 Starting, plugging all values 2,5 1 0,65 2,5 1 0,65 4 1,05 0,65 4 1,05 0,65
Squirrel-cage motors: 0<Ie≤100A Ie≤17A 0,65 Ie≤17A 0,65 0,45 0,45
AC3 Starting, switching off all values 6 1 1 0,17 10 1,05 8 1,05
motors during runing 100A<Ie Ie>17A 0,35 Ie>17A 0,35 0,35 0,35
Squirrel-cage motors: 0<Ie≤100A Ie≤17A 0,65 Ie≤17A 0,65 0,45 0,45
AC4 Starting, plugging, all values 6 1 6 1 12 1,05 10 1,05
inching 100A<Ie Ie>17A 0,35 Ie>17A 0,35 0,35 0,35
Control of electromagnetic
AC15 loads (> 72VA) - 10 1 0,7 1 1 0,4 10 1,1 0,3 10 1,1 0,3
I/Ie U/Ue L/R1) Ic/Ie Ur/Ue L/R1) I/Ie U/Ue L/R1) Ic/Ie Ur/Ue L/R1)
DC20A DC20B No-load conditions all values - - - - - - -
- - -
- -
Direct Switching of resistive loads
current DC21A DC21B including moderate all values 1 1 1 1 1 1 1,5 1,05 1 1,5 1,05 1
overloads
Switching of mixed resistive
DC22A DC22B a. induct. loads incl. moderate all values 1 1 2 1 1 2 4 1,05 2,5 4 1,05 2,5
overloads (shunt motors)
Switching of highly inductive
DC23A DC23B loads (e.g. series motors) all values 1 1 7,5 1 1 7,5 4 1,05 15 4 1,05 15
Shunt-motors:
DC3 Starting, plugging, all values 2,5 1 2 2,5 1 2 4 1,05 2,5 4 1,05 2,5
inching
Series-motors:
DC5 Starting, plugging, all values 2,5 1 7,5 2,5 1 7,5 4 1,05 15 4 1,05 15
inching
Ue Rated operational voltage, U Voltage before make, Ur Recovery voltage, Ie Rated operational current, I Current made, Ic Current broken
1) Time in milliseconds (ms)
Note:
By plugging, is understood stopping or reversing the motor rapidly By inching (jogging), is understood energizing a motor once or repeatly
by reversing motor primary connections while the motor is running. for short periods to obtain small movements of the driven mechanism.
258 D946E
Technical Data
Data according to IEC 947-3, IEC 947-5-1, VDE 0660, EN 60947-3, EN 60947-5-1
Type M10 P M10H M10HD M20 N20 N33F N40 N61 N80 N100 N200
Rated therm. current Ith open A 20 20 10 32 32 50 63 90 115 150 250
Rated therm. current Ithe encl. A 20 20 10 32 32 50 63 90 115 150 250
Rated operational voltage Ue V 440 690 1) 690 1) 690 1) 690 1) 690 1) 690 1) 690 1) 690 1) 690 1) 690 1)
Disconnection property 2)
acc. to VDE, IEC up to V 440 440 - 4) 440 440 440 690 440 440 690 690
Breaking capacity Ieff
3 x 220-440V A 160 160 35 220 220 260 380 520 740 900 1100
3 x 500V A - 100 - 160 160 200 290 380 560 680 850
3 x 660-690V A - 80 - 120 120 150 200 290 520 450 -
Utilization categ. AC21A, AC21B
Switching of resistive loads
including moderate overloads
Rated operational current Ie A 20 20 10 32 32 50 63 90 115 150 250
Utilization categ. AC23A, AC23B
Switching of motor loads
or other highly inductive loads
Rated current Ie 400V A 16 16 3,5 30 30 45 45 60 85 105 135
Power rating 220-240V kW 4 4 0,75 7,5 7,5 11 15 22 30 40 40
3-phase 3-pole 380-440V kW 7,5 7,5 1,5 15 15 22 22 30 45 55 70
500V kW - 7,5 1,5 15 15 22 22 30 45 55 70
660-690V kW - 7,5 1,5 15 15 22 18,5 30 45 45 -
Star-Delta-Switches
for squirrel cage motors
Power rating
3-phase 3-pole 220-240V kW 3,7 3,7 - 7,5 7,5 8 11 15 18,5 37 40
380-415V kW 7,5 7,5 - 15 15 18,5 18,5 25 30 40 70
Utilization category AC3
Switching of three-phase motors
Rated current Ie 400V A 12 12 2 22 22 30 30 50 60 80 135
Power rating 220-240V kW 3 3 0,37 5,5 5,5 7,5 7,5 15 18,5 25 40
3-phase 3-pole 380-440V kW 5,5 5,5 0,75 11 11 15 15 25 30 40 70
500V kW - 5,5 0,75 11 11 15 15 25 30 40 70
660-690V kW - 5,5 0,75 11 11 15 15 25 30 40 70
Utilization category AC4
squirrel cage motors, inching
Power rating 220-240V kW 0,55 0,55 - 2,2 2,2 3,7 4 5,5 6 11 18,5
3-phase 3-pole 380-440V kW 1,5 1,5 - 4 4 5,5 7,5 11 15 18,5 35
500V kW - 1,5 - 4 4 5,5 7,5 11 15 22 35
660-690V kW - 1,5 - 4 4 5,5 7,5 11 15 22 -
Utilization category AC15
Control of electromagnetic loads,
contactors,
Rated current Ie
up to 240V A 6 6 2,5 12 12 16 - - - - -
380 - 440V A 4 4 1,5 6 6 7 - - - - -
2-pole in series 500V A - 5 - 8 8 10 - - - - -
Utilization categ. DC21A, DC21B
Switching of resistive loads
Time constant L/R≤1ms
Rated current Ie
1-pole 30V A 20 20 10 32 32 40 63 80 100 150 250
60V A 4 4 - 6 6 20 30 30 30 - -
110V A 0,6 0,6 - 3 3 4 6 6 6 - -
220V A 0,5 0,5 - 0,8 0,8 0,8 1,3 1,3 1,3 2,5 2,5
440V A - - - 0,4 0,4 0,4 0,6 0,6 0,6 0,7 0,7
Utilization category DC3 - DC5
Switching of shunt motors
and series motors
Time constant L/R≤15ms
Rated current Ie
1-pole 30V A 8 8 - 13 13 16 25 32 40 60 100
60V A 1 1 - 2,4 2,4 4 12 12 12 - -
110V A 0,3 0,3 - 0,5 0,5 1,6 2,4 2,4 2,4 - -
Protection class ot terminals IP00
1)
IP20 IP20 IP00 IP00 IP20 IP00 IP00 IP00 IP00 IP00
1) suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 6kV. Data for other conditions on request
2) valid for lines with grounded common neutral termination, overvoltage category III , pollution degree 3.
3) Protection degree of the terminals with connected insulated conductor. Additional protection with terminal cover (KLAD).
4) Fulfil the requirements acc. to load switches.
D946E 259
Technical Data
Data according to IEC 947-3, IEC 947-5-1, VDE 0660, EN 60947-3, EN 60947-5-1
Type M10 P M10H M10HD M20 N20 N33F N40 N61 N80 N100 N200
Cable cross-sections
solid mm2 1-2,5 1-2,51) 1-2,51) 1,5-6 1,5-6 2,5-10 2,5-16 1) 6-25 1) 6-35 10-50 1) 50-150
flexible mm2 0,75-2,5 0,75-2,51) 0,75-2,51) 1-4 1-4 1,5- 6 2,5-10 1) 6-25 1) 6-35 10-35 1) 35-120
flexible w. multicore cable end mm2 0,75-2,5 0,75-1,5 0,75-1,5 1-4 1-4 1,5- 6 2,5-6 6-16 6-35 10-25 -
Conductors to clamp per pole 2 2 2 2 2 2 2 1 1 1 1
Size of terminal screw M3 M3,5 M3,5 M4 M4 M4 M5 2xM5 2xM5 2xM6 M10
Tightening torque Nm 0,6-1,2 0,8-1,4 0,8-1,4 1,2-1,8 1,2-1,8 1,2-1,8 2,5-3 2,5-3 2,5-3 3,5-4,5 23
lb.inch 5-11 7-12 7-12 11-16 11-16 11-16 22-26 22-26 22-26 31-40 202
Short-time capacity
Load duration 3s A 100 100 - 200 200 350 400 600 720 1000 2000
10s A 60 60 - 130 130 230 250 400 480 600 1200
Note: Ratings applies to 30s A 35 35 - 85 85 110 160 250 300 500 600
contacts already closed 60s A 25 25 - 65 65 80 110 200 250 370 480
Type M10 P M10H M10HD M20 N20 N33F N61 N80 N100 N200 L400
Rated voltage V~ 300 600 600 600 600 600 600 600 600 600 600
440-480V hp - 5 - 10 10 25 35 40 40 60 60
550-600V hp - 7½ - 15 15 30 40 50 50 75 75
Fuse size (RK5) Man. Motor Controller A 40 2) 40 - 80 80 150 150 200 300 350 350
5kA / 600V and Motor Disconnect
Heavy pilot duty AC A300 A600 B600 A600 A600 A600 A600 A600 A600 A600 A600
Tightening torque Nm 1-1.2 1-1.4 1-1.4 1.7-1.8 1.7-1.8 1.2-1.8 2.8 2.8 4.5 23 40
lb.inch 9-11 9-13 9-13 15-16 15-16 11-16 25 25 40 202 352
260 D946E
Technical Data
Data according to IEC 947-3, IEC 947-5-1, VDE 0660, EN 60947-3, EN 60947-5-1
Type L100 L160 L400 L600 L800 L1200
Rated insulation voltage Ui
V 690 2) 690 2) 690 2) 690 2) 690 2) 690 2)
Rated thermal current Ith openA 125 180 400 600 800 1200
Rated thermal current Ithe encl. A 125 180 400 600 800 1200
busbar busbar busbar busbar
with conductor mm2 50 70 40x5 40x10 2x40x10 2x50x10
Utilization category AC21A, AC21B
Switching of resistive loads,
including moderate overloads
Rated operational current Ie A 125 180 400 400 400 400
Shot-time current-carrying capacity
Load duration 1s - - 4800 6500 8500 10000
3s 800 1200 3600 5000 6500 8000
10s 500 800 2000 3200 4000 5800
Note: Ratings applies to 30s 320 480 1200 1700 2200 3200
contacts already closed 60s 180 380 960 1300 1700 2300
Cable cross-sections
solid or stranded mm2 25-50 1) cable lug busbar busbar busbar busbar
flexible mm2 25-50 1) 70 40x5 40x10 2x40x10 2x50x10
flexible with multicore cable end mm2 25-35 - - - - -
Number of conductors to clamp per pole 1 1 1 2 1 1
Size of terminal screw 2xM5 M8 M12 M16 M16 M16
Tightening torque Nm 3 12 40 98 98 98
lb.inch 26 105 352 862 862 862
Short circuit protection
Max. fuse size slow, gL (gG) A 125 200 400 630 800 1250
1) Maximum cable cross-section with prepared conductor
2) suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 6kV.
Data for other conditions on request
Mechanical Life
Schwitch type M10, M10H M20, N20, N33F N40, N60, N80 N100, N200
Note: The minimum mechanical and electrical life is defined according to IEC/EN60946-3 (approx. 10.000 operations).
D946E 261
Dimensions (mm)
Panel mounting E
M10 - N100 N200
M4H mm 30 28 29,5 12,5 38,5 50,5 62,5 74,5 86,5 98,5 110,5 122,5
262 D946E
Dimensions (mm)
Flush mounting UP
M10
Base mounting V
M10H - N100 N200
D946E 263
Dimensions (mm)
Plastic enclosed switches P, PF
M10 - N61
N61, N80
264 D946E
Dimensions (mm)
Plastic enclosure horizontal PLF (Replacement for cast aluminium enclosure G, GF)
N40, N61, N80
A 182 254
B 167 239
C 120 190
D - 65
P 2 x Ø40,5 (M40) 4 x Ø40,5 (M40)
D946E 265
Dimensions (mm)
Load Switches
Panel mounting E
L100 - 400, L800, L1200 L600
Base mounting V
L100 - 400, L800, L1200 L600
266 D946E
Operating Knobs and Handles
Instrument knob G.
Type A B C D E
M10, M10H, M20 23 28 24 14 4
N20, N33F 27 36 32 18 3
N40, N61, N80, L100, L160 36 47 42 24 3,5
N100, N200 48,10 75 63 37,5 -
Toggle knob K.
Type A B E
M10, M10H, M20 18,5 28 4
N20, N33F 24 36 3
Hand wheel HR
N100, N200,
L400, L600, L800, L1200
Escutcheon plates
Type A B Type A B C
M10, M10H, M20 48 7,5 M10, M10H, M20 48 12 7,5
N20, N33F 64 7,5 N20, N33F 64 14 7,5
N40, N61, N80, L100, L160 88 8 N40, N61, N80, L100, L160 88 22 8
N100, N200, L400, L600, L800, L1200 132 9 N100, N200, L400, L600, L800, L1200 132 31 9
D946E 267
268 D946E
Door couplings
Dimension T is a minimum value. In case of order the dimension T is necessary.
D946E 269
Key operated switches SA
Type A B C D D1 D2 F Type A C D F
M10H, M20 48 36 18 17,5 5 18,5 52,5 M10H, M20 48 18 22 57
N20, N33F 64 48 10 17,5 5 18,5 52,5 N20, N33F 64 8 22 57 Dimension L
N40,N61 88 68 23,5 15 6 18,5 50 Dimension L see page 262 N40,N61 88 15 15 50 see page 263
N20 66 80 94 108
N33F 92 110 110 128
N40 92 110 - -
N61 110 - - -
270 D946E
Key operated switches
Type A B C D D1 D2 F Type A C D F
M10H, M20 48 36 25 21 5 22,5 49 M10H, M20 48 25 21 49
D946E 271
Padlock devices
Padlock device SV1 (max. 2 padlocks with stirrup Ø6mm) Padlock device SV164
Mounting holes Mounting holes
M10H, M20 design E, V M10H - N33F design E, V
Padlock device SV4 (max. 3 padlocks with stirrup Ø6mm) Padlock device SV4 (max. 3 padlocks with stirrup Ø6mm)
M10H - N33F N40 - N80, L100 - L160
Padlock device SV488
Mounting holes N20, N33F Mounting holes
design E, V design E, V
Typ B D1 D2
N20, N33F 48 5 17
272 D946E
Interlocks, Moisture caps
Type A B C D D1 D2 D3 E F G H
Type A B C D D1 D2 D3 E F G
M10H, M20 60 36 3 22,5 5 8 26 90 45 32
N20, N33F 60 36 3 22,5 5 10 26 90 45 32
N40, N601 N80, L100, L160 90 68 4 25 6 12 29 142 61 61,5
N100, N200, L400, L600, L800, L1200 140 110 4 41 7 15 29 180 83 90,5 1) only at +ET
D946E 273
Fire Brigade Switch
274 D946E
D946E 275
276 D946E