ELRO Bratt Pan Maintenance
ELRO Bratt Pan Maintenance
ELRO Bratt Pan Maintenance
When operating the appliance with a filter, the customer must make sure that the manufacturer’s
instructions (water hardness / filter capacity) are correctly entered in the appliance.
Otherwise, repairs and maintenance may only be carried out by ELRO After Sales Service or by service
companies authorized by ELRO. In other cases, all guarantee and regress claims are invalid and the
appliance may not be cleaned with high pressure (HPC) or a water jet.
This also applies to additions or adaptations which were not authorized by ELRO.
It is recommended to have your appliance checked for proper functioning every 4 years by ELRO After
Sales Service.
An annual check must be carried out and safety components must be replaced every 8 years!
7 Information/Service
Press (5) in the main menu. You can now proceed to the following settings:
(3) Language
(B) –
(C) –
(D) –
7.1 Contrast
By pressing (1)(2), you can adjust the display contrast. The white bar indicates
the intensity.
7.2 Language
With (1) to (5), you can select the language. The active
language is displayed with a white background.
With (3), you access the appliance information menu. You can view appliance
information here.
Browse forward and back with (B)(C). Press (A) to return to the main menu.
X101535E 27
address
information
appliance type
Appliance temperature
Core temperature
Pressure in heating
system
Pressure in cooking
chamber
Energy consumption
Consumption Highspeed
IP address appliance
7.5 User code
Display control 90 has various user codes. Depending on the user code, the user has
various rights:
Enter the user code with (2) to (4). Confirm entry with (D).
After confirmation, the corresponding configuration menu for the user code is
(B).
X101535E 28
Here, you can create, modify and save cooking programs in the cookbook (1). Furthermore, you can
modify with (2) the time zone, clock and date settings.
(1) Cookbook
(3) –
(4) –
(5) –
(C) –
(D) –
7.6.1 Cookbook
Quit the cookbook with (A). Press (B)(C) to browse in the cookbook. By pressing (1) to (5),
Select an existing cooking program. Make the desired modifications. If you press (A) you will be asked,
(C) Edit
(D) –
(5) –
(C) –
(D) –
X101535E 29
When you change a fixed cooking program, you can either save the program under a new name or
discard
it.
Enter the user code with (2) to (4). Confirm entry with (D).
You can delete the suggested text or correct typing errors with
(C).
The program has been saved under a new name. It will be listed alpha-numerically
(C) –
(D) –
X101535E 30
Page 1
(C) To page 2
(D) –
Page 2
(2) Timeout
(4) –
(5) –
(C) To page 3
(D) –
The filter capacity is entered via the user code „cooking programs settings“. The following entries must
be made at appliance commissioning or when the filter is changed: confirm the filter capacity and the
filter
replacement!
(1) Filter
(C) –
(D) –
Before reaching the filter capacity, a maintenance message is generated asking you to
Replace the filter. Confirm replacement with the user code „cooking programs
settings“. Press (5) filter replacement – the filter capacity values are reset!
When replacing the filter, check the filter capacity based on the filter manufacturer’s
data!
If you do not change the filter and the filter capacity is depleted, you cannot start ANY
pressure cooking process. You will be informed immediately with the error message
on the left. You MUST now carry out and then confirm the filter replacement.
X101535E 31
(2)(3)
Repeat if necessary.
Select hot water (5) with (D), fill 10 litres of water into the measuring
Repeat if necessary.
Return to the main menu with (A), select WDS*) with (C). Set 10 litres with (2)(3). Check both
cold and hot water! Start WDS*) with (D). Check the water volume flowing into the measuring
Page 1
Page 1
7.7.5 Horn
Page 2
7.7.6 Timeout
Page 2
(2) Timeout
Page 2
Write down the error message and conditions. This information is important for ELRO After Sales
Service.
If the steam valve blows off steam continuously during a pressure cooking process or if the maximum
temperature is not reached, this could indicate a faulty setting of the boiling point at the appliance
location.
If the boiling point setting on the appliance (i.e. the maximum temperature setting) at the location does
not
correspond with the actual boiling point, it must be corrected according to the installation instructions
References :
ELRO WebSite.