Product Description
Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced
pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped
construction for stable operation allowing the use of high reduced pressure.
Download
Technical Features
Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio Suitable for accumulator circuits since the absence of pilot control flow
and should not exceed 3000 psi (210 bar). results in reduced secondary circuit leakage.
Leakage specified in Technical Data is out of port 3 with a supply Direct acting concept provides highly reliable operation in
pressure of 2000 psi (140 bar) and the valve set at mid range. This contaminated systems, especially at dead headed conditions.
leakage is directly proportional to pressure differential and inversely
proportional to viscosity expressed in centistokes.
All three-port pressure reducing and reducing/relieving cartridges are Unlike pilot operated versions, direct acting valves exhibit a
physically interchangeable (i.e. same flow path, same cavity for a transitional step between reducing and relieving modes. This step
given frame size). When considering mounting configurations, it is equals 5% of the high end of the adjustment range, independent of
sometimes recommended that a full capacity return line (port 3) be the valve setting. Therefore, these valves may not be suitable for
used with reducing/relieving cartridges. counterbalancing applications.
Full reverse flow from reduced pressure (port 1) to inlet (port 2) may Direct operated version offers superior dynamic response compared to
cause the main spool to close. If reverse free flow is required in the equivalent pilot operated models.
circuit, consider adding a separate check valve to the circuit.
All spring ranges are tested for correct operation with 5000 psi (350 Incorporates the Sun floating style construction to minimize the
bar) inlet pressure. possibility of internal parts binding due to excessive installation torque
and/or cavity/cartridge machining variations.
Technical Data
U.S. Units Metric Units
Cavity T-2A
Capacity 20 gpm 80 L/min.
Factory Pressure Settings Established at blocked control port (dead headed)
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 3 in³/min. 50 cc/min.
Series (from Cavity) Series 2
Adjustment - Number of Clockwise Turns to Increase Setting 5
Valve Hex Size 1 1/8 in. 28,6 mm
Valve Installation Torque 45 - 50 lbf ft 60 - 70 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 80 - 90 lbf in. 9 - 10 Nm
Seal Kits - Cartridge Buna: 990-202-007
Seal Kits - Cartridge Viton: 990-202-006
Model Weight 0.79 lb. 0.36 kg.
PRFB-LAN
L Standard Screw Adjustment A 750 - 3000 psi (50 - 210 bar), N Buna-N
Standard Options 1000 psi (70 bar) Standard Standard Options
Setting
Standard Options
C* Tamper Resistant - Factory V Viton
Set
B 300 - 1500 psi (20 - 105 bar),
K Handknob
500 psi (35 bar) Standard
Setting
D 200 - 800 psi (14 - 55 bar),
400 psi (28 bar) Standard
Setting
E 100 - 400 psi (7 - 28 bar),
200 psi (14 bar) Standard
Setting
S 50 - 200 psi (3,5 - 14 bar),
100 psi (7 bar) Standard
Setting
| | | | | |
Copyright © 2009-2010 Sun Hydraulics Corporation. All rights reserved.